Conformity Assessment of Medical Devices Under The New MDR

Similar documents
Update on the IVDR. Sue Spencer

ASQ Tappan Zee Section Medical Devices, New Regulations and Standards. 26 th September / V. Fischer / Rev. 01

Ready or Not: The New Medical Device Regulations Are Here!

Regulation of software a medical device

GUIDANCE NOTES FOR MANUFACTURERS OF CLASS I MEDICAL DEVICES

European Medical Device Regulations (MDR): What To Expect

The challenges of software medical device regulation.

Medical Devices Regulation (MDR) Readiness Review

Implications of the new MDR from a Product Testing and Certification Perspective

Due diligence in the European medical devices industry

Medical Device Regulatory Framework 9 SEPTEMBER 2015 FUNDISA CONFERENCE JANE ROGERS

Medical Device Regulation Overview

FINAL DOCUMENT. Global Harmonization Task Force (revision of GHTF/SG1/N29:2005)

MDR ID: Definition: Applicable:

EU MDR Timeline. Dr. Christian B. Fulda Jones Day FDLI Annual Conference Access materials at fdli.org/annual2018

The EU s In Vitro Diagnostics (IVD) Regulation:

MDR. Device Classification Conformity Assessment Safety & Performance Requirements Technical Documentation

GENERAL AND ORGANISATIONAL REQUIREMENTS

TERMS AND DEFINITIONS

Medical Devices. LATVIA LAWIN Klavins & Slaidins

GS1 Ireland Healthcare User Group (HUG) Information Day

EMA perspective on increasing focus on review of device components of medicinal products

IVD Regulation 2017/746

MEDICAL DEVICE. Technical file.

Classification under the IVD Regulation

Changes to the Medical Devices Directive and affect on Manufacturers

HOW TO APPLY FOR MEDICAL DEVICE REGISTRATION UNDER MEDICAL DEVICE ACT 2012 (ACT 737)

GETTING READY FOR THE EUROPEAN UNION (EU) MEDICAL DEVICE REGULATION (MDR)

Update on Regulatory Environment- Europe Experience with 2007/47/EC M5 & Discussions on Possible Recast of EU Medical Device Regulations

Guide for Class I Manufacturers on Compliance with European Communities (Medical Devices) Regulations, 1994

The New EU IVDR. Overview of the Main Changes & Clinical Data Requirements. Advance Regulatory Consulting Ltd.

DRAFT MEDICAL DEVICE GUIDANCE DOCUMENT

The Medical Device Coordination Group: a new Authority Under EU Device Regulations

Guide for Ethics Committees on Clinical Investigation of Medical Devices

MEDICAL DEVICE CLINICAL INVESTIGATIONS AND ISO 14155

Recommendations on Medical Device and IVD Field Safety Corrective Actions and Recalls using Unique Device Identifiers & GS1 Standards

Medical Device Epidemiology Introduction

UNANNOUNCED EU MEDICAL DEVICE AUDITS BY NOTIFIED BODIES: IMPACT ON SUPPLIERS

Recast Medical Device directives Impacts on materiovigilance

VIGILANZA E SORVEGLIANZA POST- COMMERCIALIZZAZIONE

Technical Documentation

MedDev Rev 4 Medical Devices Regulation. Clinical Evidence Requirements Key Changes and Clarifications. Alan Eller 21 March 2017

Regulating Cell Therapy: An Ex-Regulators Perspective

ISO INTERNATIONAL STANDARD

ISO INTERNATIONAL STANDARD. Biological evaluation of medical devices Part 1: Evaluation and testing within a risk management process

Regulations and Directives Past, Present, Future

EUROPEAN COMMISSION ENTERPRISE AND INDUSTRY DIRECTORATE-GENERAL GUIDELINES ON MEDICAL DEVICES

CE Marking for Medical devices

New EU Regulation on medical devices

Panel Discussion: European Medical Device Regulations Preparing for the Storm Moderator: Lenita Y. Sims Spears, Senior Quality Consultant/Senior

Conformity Assessment of Own Brand Labelling

Biological evaluation of medical devices --

IVDR Workshop Diagnostik Akademie, Sven Hoffmann Global Head of Technical Competence Center IVD TÜV Rheinland LGA Products GmbH

FREQUENTLY ASKED QUESTIONS DURING ELECTRO-MEDICAL DEVICE MARKET ACCESS

AUSTRALIAN MEDICAL DEVICES GUIDANCE DOCUMENT NUMBER 5. The Declaration of Conformity

Flexible, robust solutions from BSI. An In Vitro Diagnostic Notified Body. Expertise and experience. IVD regulatory solutions

PART 1 DEVICE MASTER FILE

The new EU Regulations on medical devices and first steps of their implementation

POSITION PAPER Moving from the MDD to the MDR

FINAL DOCUMENT. International Medical Device Regulators Forum. Medical Device Regulatory Audit Reports

Clinical Evaluation and Clinical Investigation update MDR

Medical Device Directive

ASEAN AGREEMENT ON MEDICAL DEVICE DIRECTIVE

PROPOSED REVISED DOCUMENT

WELMEC European cooperation in legal metrology

ISO INTERNATIONAL STANDARD

The importance of implementing a continuous cycle of improvement for medical devices. Roles for various stakeholders

Medical devices utilizing animal tissues and their derivatives. Part 1: Application of risk management

MedDev and NB-MED Recommendations

Brussels, C(2017) 8179 final. Guidelines

MEDICAL DEVICE GUIDANCE

Surveillance and Medical Devices

Pharmabiotics: a Regulatory Hurdle in Europe

The rules governing medicinal products in the European Union. Presentation and content of the dossier Edition

GUIDELINES ON MEDICAL DEVICES GUIDE FOR COMPETENT AUTHORITIES IN MAKING AN ASSESSMENT OF CLINICAL INVESTIGATION NOTIFICATION

Post market Surveillance ISO EU Medical Device Regulation

GUIDELINES ON MEDICAL DEVICES

Update on Recast of IVD Directive

INSTRUCTIONS FOR CERTIFICATION OF FACTORY PRODUCTION CONTROL

Post Market Surveillance (including PMCF): common non compliances

Understanding Clinical Equivalence

Guide to field safety corrective actions for medical devices and in-vitro diagnostic medical devices

EUROPEAN COMMISSION DIRECTORATE-GENERAL FOR HEALTH AND FOOD SAFETY. EudraLex. Volume 4

The Children s Hospital of Philadelphia Committees for the Protection of Human Subjects Policies and Procedures Determination of IND/IDE Requirement

GUIDELINES ON MEDICAL DEVICES CLINICAL EVALUATION: A GUIDE FOR MANUFACTURERS AND NOTIFIED BODIES

Manual for ITC's Clients 2016 Conformity assessment of in vitro diagnostic medical devices pursuant to Council Directive 98/79/EC

Laboratorio di Tecnologie Biomediche

MEDICAL DEVICES REGULATORY SYSTEM

Checklist for the assessment based on the standards

POLICY FOR THE DECONTAMINATION OF FLEXIBLE ENDOSCOPES

Medical Technologies in Belgium: overview & challenges. Karel Verlinde - bemedtech

Inspection of the conduct of clinical evaluations on medical devices in the premises of healthcare providers

Information for Manufacturers on the Inspection of Manufacturing Site(s) (Assessment of the Quality Management System)

CORRESPONDENTS' GUIDELINES No 3

The Role of a Notified Body in Defining Risk Assessment for a Recombinant Protein Used in a Medical Device Case Study

Guide for Manufacturers and Sponsors on Clinical Investigations Carried Out in Ireland

KRONOS WORLDWIDE, INC. SAFE HARBOR PRIVACY POLICY Effective December 1, 2009 Amended and Restated as of July 20, 2012

COUNTRY OVERVIEW: THAILAND. August 2012 SPECIAL REPRINT. By Rarana Phanudulkitti

Agenzia Italiana del Farmaco

Transcription:

Conformity Assessment of Medical Devices Under The New MDR (Dec. 06, 2017) Tina Lochner, Medcert Slide 1

Agenda Scope: MDR Article 1 and 2 MDR Conformity Assessment: MHRA* (UK Competent Authority) MDR Annex IX, X, XI Class I, IIa, IIb, III and Custom Made Devices Must Know What requirements need to be met for a conformity assessment? Summary *Medicines and Healthcare Products Agency Slide 2

Scope of the new MDR - Article 1egulation [1.] This Regulation lays down rules concerning the placing on the market, making available on the market or putting into service of medical devices for human use and accessories for such devices in the Union. This Regulation also applies to clinical investigations concerning such medical devices and accessories conducted in the Union. [2.] This Regulation shall also apply, as from the date of application of common specifications adopted pursuant to Article 9, to the groups of products without an intended medical purpose that are listed in Annex XVI, e.g. contact lenses; equipment for liposuction; infra-red, visible light and ultra-violet emitting equipment; equipment intended for brain stimulation that apply electrical currents or magnetic or electromagnetic fields; substances, combinations of substances, or items intended to be used for facial or other dermal or mucous membrane filling by subcutaneous, submucous or intradermal injection or other introduction. [3.] Devices with both a medical and a non-medical intended purpose shall fulfil cumulatively the requirements applicable to devices with an intended medical purpose and those applicable to devices without an intended medical purpose. Slide 3

Scope of the new MDR - Article 2egulation Medical device means any instrument, apparatus, appliance, software, implant, reagent, material or other article intended by the manufacturer to be used, alone or in combination, for human beings for one or more of the following specific medical purposes: diagnosis, prevention, monitoring, prediction, prognosis, treatment or alleviation of disease, diagnosis, monitoring, treatment, alleviation of, or compensation for, an injury or disability, investigation, replacement or modification of the anatomy or of a physiological or pathological process or state, providing information by means of in vitro examination of specimens derived from the human body, including organ, blood and tissue donations, and which does not achieve its principal intended action by pharmacological, immunological or metabolic means, in or on the human body, but which may be assisted in its function by such means. Slide 4

MDR Conformity Assessment ANNEX VIII CLASSIFICATION RULES CHAPTER I Definitions specific to classification rules CHAPTER II Implementing rules CHAPTER III Classification rules ANNEX IX CONFORMITY ASSESSMENT BASED ON A QUALITY MANAGEMENT SYSTEM AND ON ASSESSMENT OF TECHNICAL DOCUMENTATION CHAPTER I Quality Management System CHAPTER II Assessment of the technical documentation CHAPTER III Administrative provisions ANNEX X CONFORMITY ASSESSMENT BASED ON TYPE-EXAMINATION ANNEX XI CONFORMITY ASSESSMENT BASED ON PRODUCT CONFORMITY VERIFICATION PART A Production quality assurance PART B Product verification Slide 5

Device Classification Slide 6

Classification Conformity Assessment Slide 7

Annex IX Conformity Assessment Based On A Quality Management System And On Assessment Of Technical Documentation - Quality management system assessment: application with NB and Notified Body access to the technical documentation - Quality management system audit: including technical documentation assessment for devices selected on a representative basis per published guidance developed by the MDCG* -> Notified Body documents its rationale for the samples taken. - Assessment of the technical documentation: special assessment procedures for certain class III and class IIb devices** require that NB transmits a clinical evaluation assessment report, along with the manufacturer's clinical evaluation documentation, to the Commission for transmission to the relevant expert panel; NB to seek scientific opinion from a competent authority or EMA, change assessment, and batch verification based on official certificates issued by a Member State laboratory or a designated laboratory or description of ADME and other properties where applicable *Medical Device Coordination Group **e.g. devices incorporating a medicinal substance, devices incorporating human blood or plasma derivative or a substance that, if used separately, may be considered to be a medicinal product, devices manufactured utilizing derivatives of tissues or cells of human origin, devices manufactured utilizing animal tissue rendered non-viable or utilizing non-viable products derived from animal tissue, devices that are composed of substances or of combinations of substances that are absorbed by or locally dispersed in the human body Slide 8

Annex IX Conformity Assessment Based On A Quality Management System And On Assessment Of Technical Documentation - Assessment of substantial changes to the quality management system or the device-range covered - Surveillance assessment: Audits at least once every 12 months including manufacturer's suppliers and/or subcontractors; unannounced audits randomly performed at least once every five years on the site of the manufacturer and, where appropriate, of the manufacturer's suppliers and/or subcontractors combined with the periodic surveillance assessment or be performed in addition; surveillance assessment to include an assessment of the technical documentation (class IIa/IIb devices) or a test of the approved parts and/or materials that are essential for the integrity of the device, including, where appropriate, a check that the quantities of produced or purchased parts and/or materials correspond to the quantities of finished devices (class III). Slide 9

Annex X Assessment Based On Type-Examination EU type-examination is the procedure whereby a Notified Body ascertains and certifies that a device, including its technical documentation and relevant life cycle processes and a corresponding representative sample of the device production envisaged, fulfils the relevant provisions of this Regulation. - Application with NB - NB assessment of technical documentation - NB review the clinical evidence - NB to carry out or arrange for the appropriate assessments and the physical or laboratory tests - Change assessment Slide 10

Annex XI Conformity Assessment Based On Product Conformity Verification The objective of the conformity assessment based on product conformity verification is to ensure that devices conform to the type for which an EU type-examination certificate has been issued, and that they meet the provisions of this Regulation which apply to them. PART A PRODUCTION QUALITY ASSURANCE - Quality management system assessment: application with NB - Surveillance assessment as in Annex IX - Batch verification in the case of devices incorporating, as an integral part, a medicinal substance which, if used separately, would be considered to be a medicinal product derived from human blood or human plasma as in Annex IX - EU declaration of conformity by manufacturer and technical documentation assessment by NB for the devices selected on a representative basis Slide 11

Annex XI Conformity Assessment Based On Product Conformity Verification PART B PRODUCT VERIFICATION Product verification shall be understood to be the procedure whereby after examination of every manufactured device, the manufacturer, by issuing an EU declaration of conformity in accordance with Article 19 and Annex IV, shall be deemed to ensure and to declare that the devices which have been subject to the procedure set out in Sections 14 and 15 conform to the type described in the EU type-examination certificate and meet the requirements of this Regulation which apply to them. Verification by examination and testing of every product or batch verification of each batch in the case of devices incorporating, as an integral part, a medicinal substance which, if used separately, would be considered to be a medicinal product derived from human blood or human plasma. Slide 12

Must know The requirement for manufacturers to conduct a conformity assessment before placing their device on the market, and for higher risk devices to involve a Notified Body, is unchanged. Slide 13

Class I devices: Similar to the current MDD Annex VII EC declaration of conformity. - New EU Declaration of Conformity (new Article 19) prepared by manufacturer, - Fulfill general obligations of all manufacturers (new Article 10), - Involvement of a Notified Body is limited for Class I devices, and only required for sterile devices, reusable surgical instruments or devices with a measuring function. Slide 14

Class IIa devices: Similar to the current MDD, manufacturers of Class IIa devices have the option of following the same conformity assessment route as for Class IIb devices, the new EU MDR s Annex IX, with the Notified Body only assessing representative technical documentation. Manufacturers may choose not to follow the full quality management system approach essentially similar to the current MDD s Annex VII EC declaration of Conformity combined with either Annex IV or Annex V: - Compile the new technical documentation (new Annex II) - Manufacturer prepares the new EU declaration of conformity (new Article 19) - and then the Notified Body either: - (a) assesses the Technical Documentation of a representative sample of the devices (Annex XI, Part A, Section 10), - or (b) carries out tests to confirm the conformity of the devices (Annex XI, Part B, Section 18). Slide 15

Class IIb devices: Similar to the current MDD, manufacturers of Class IIb devices have the option of following the same conformity assessment route as for Class III devices, the new EU MDR s Annex IX with the difference that the Notified Body is only required to assess the technical documentation of at least one representative device of each generic device group produced by the manufacturer. As with the current MDD, there are alternative routes for manufacturers of Class IIb devices who chose not to follow the full quality management system approach. These are the same as those for Class III devices with one fewer alternative available to manufacturers of Class IIb devices compared to the MDD: there is no equivalent to the MDD s Annex VI product quality assurance. Manufacturers currently following this route will have to choose an option from the new Annex XI. Either Part A, Production Quality Assurance, or Part B, Product Verification. Slide 16

Class III devices: The current MDD s Annex II full quality assurance route will be replaced by the new EU MDR s Annex IX conformity assessment based on quality management system assurance and assessment of the technical documentation. There are alternatives for those manufacturers who chose not to follow the full quality management system approach: the current MDD alternative for Class III devices of Annex III EC type-examination, combined with either Annex IV EC verification or Annex V production quality assurance will be replaced by the new EU MDR s Annex X conformity assessment based on type examination combined with new Annex XI conformity assessment based on product conformity verification. This is essentially identical to those of the current MDD. The new EU MDR s Annex XI conformity assessment based on product conformity verification includes both the MDD s current options; Part A being the new Production Quality Assurance route, replacing the current MDD s Annex V production quality assurance. Part B being the new Product Verification route, replacing the current MDD s Annex IV EC verification. Slide 17

Custom made devices: Unlike the current MDD where the requirements for custom made devices are part of the current MDD Annex VIII the new EU MDR has a dedicated Annex, Annex XIII procedure for custom made devices. However, the requirements to draw up a statement about the device and keep records etc. are fundamentally the same as in the current MDD. The exception being class III custom made devices, where a quality system assessment by a Notified Body is required; either the quality management system assessment of the new Annex IX, Chapter 1 or the Production Quality Assurance of the new Annex XI, Part A. Slide 18

Slide 19

Slide 20

Slide 21

Slide 22

Slide 23

What requirements need to be met for a conformity assessment? 1. General Safety and Performance Requirements (Annex I MDR): - Benefits must outweigh risks and achieve claimed performance supported by clinical evidence and investigation - Chemical, physical and biological properties for medical devices disclosed - [Performance characteristics for ivds disclosed] - Information supplied by manufacturer with the device; e.g. IFU and correct device labelling 2. Technical documentation (Annex II MDR) 3. Harmonized standards / common specifications (Articles 8 and 9 MDR) See Annex IX, X and XI of MDR for details Slide 24

Summary Slide 25

Slide 26

Visit us: www.med-cert.us (www.med-cert.com) Slide 27