DIVISION VI INDIVIDUAL GRINDER PUMP INSTALLATIONS

Similar documents
TYPES OF SEWAGE PUMPS. Solids Handling Pumps: Grinder Pumps: Effluent Pumps:

Permit for Construction of an Extension to a JEA Drinking Water Distribution System and/or JEA Wastewater Collection/Transmission System

Village of Arlington Heights. Sewer Back-up Rebate Program

SECTION PACKAGE BOOSTER PUMP STATIONS

TYPICAL INSTALLATION INSTRUCTIONS

2. Water Pressure Booster Systems. 3. Duplex Pedestal Type Sump Pumps.

SPECIAL SPECIFICATION 3504 Septic Tank System

SECTION INFLUENT EQUALIZATION TANK PUMPS

SEWER SYSTEM DESIGN GUIDELINES

SMALL WORKS ROSTER APPLICATION INSTRUCTIONS COMPLETE AND RETURN ALL SECTIONS OF THE APPLICATION PACKAGE. FOLLOWING:

SECTION SLUDGE HOLDING TANK DECANTER PUMP

CITY OF DENTON ON-SITE SEWAGE FACILITY PERMIT APPLICATION. Permit Number

PLAN CHECK CORRECTION SHEET FOR METHANE MITIGATION SYSTEMS 2014 LAPC

Statement of Existing (This is not a Permit)

PLANNING GUIDE FOR SINGLE CUSTOMER SUBSTATIONS SERVED FROM TRANSMISSION LINES

Property Owner's Name: Telephone #: Mailing Address: System Address (if different): Directions to location of installation:

Received by:* Date Received:* Zoning Approval:* Date:* PERMIT#:* *ZONING: *SETBACKS: FRONT ft/ SIDE ft/ REAR ft *FLOOD ZONE:

For more information, visit our web site at: h2o.enr.state.nc.us/ndpu/

NOTICE OF INTENT TO USE THE GENERAL PERMIT FOR CONSTRUCTION OF WATER MAIN EXTENSIONS FOR PWSs

Division II Contractors

SECTION FOUNTAINS

Figure 1. Report of Inspection Process Flowchart.

DIVISION 33 UTILITIES SECTION PACKAGED SEWAGE GRINDER PUMP UNITS

SECTION 820 PUMP STATION DEMOLITION AND SITE RESTORATION

West Virginia Department of Health & Human Resources Department of Health

BYRON TOWNSHIP BUILDING PERMIT APPLICATION 8085 Byron Center Ave SW., Byron Center, MI /Fax

Existing System Evaluation Report for Onsite Wastewater Systems

INSPECTION AND ACCEPTANCE FOR MAINTENANCE

SECTION 4 - DESIGN STANDARDS FOR WATER DISTRIBUTION FACILITIES

SEPTIC TANK CONSTRUCTION GUIDELINES

Pressure Sewer Systems. Why Use a Barnes Pressure Sewer System?

Property is served by unmetered public or private water. Not normally applicable to this item. Page 1 of 5 Supplement to HHE-240 Rev.

PUMP STATION CHECK LIST

CITY OF HOMESTEAD Utility Rights-of-Way Use Permit Application

THIS IS A COURTESY COPY OF THIS RULE. ALL OF THE DEPARTMENT S RULES ARE COMPILED IN TITLE 7 OF THE NEW JERSEY ADMINISTRATIVE CODE.

Department of Transportation Pierre Region Office 104 S. Garfield Bldg. A Pierre, South Dakota / FAX: 605/

BIDDING SCHEDULE SEWER LIFT STATION NO. 2 REPLACEMENT PROJECT CITY OF ALHAMBRA City s Project No. N2M17-83

READ ONLY. Adopting Agency BSC SFM. Adopt Entire Chapter Adopt Entire Chapter as amended (amended sections listed below)

This is only a general checklist; please refer to the CVWD Development Design Manual (DDM) for all requirements and regulations.

BERKELEY COUNTY ENGINEERING AND

AQUAROBIC MINI-PLANT TM

Sanitary Sewer Extensions, Lift Stations, and Force Mains Engineering Report Form. I. General Information. 1. Name of Facility:

WASTEWATER PUMPING STATION INVENTORY

INSTALLING A SEPTIC SYSTEM IN LIVINGSTON COUNTY LIVINGSTON COUNTY PUBLIC HEALTH DEPARTMENT 310 TORRANCE AVENUE PONTIAC, IL /

ON SITE SEPTIC SYSTEM EVALUATION PEBBLE RIDGE COMMUNITY DOYLESTOWN TOWNSHIP February Responsibility of this Committee

The following is required for a complete permit submittal for each unit.

On-Site Sewage Program & Well Program Request for Service

Welcome to Douglas County PUD

HUP. Performance Data. Wholesale Products Page: Section: Performance Data Dated: January RPM: 1550 Discharge: 1" Solids: 1/8" GPM: TDH:

LI STATIONS N-03 & N-06 PLACEMENT BID # B May 18, 2016 Addendum 2

***************************************************************************************************************

Simplex Fiberglass Lift Station: Hard Piped

G2D Series Performance Data Discharge: 1-1/4 Solids: 1/4. Wholesale Products Page: JP10075SSD-1 Section: Performance Data Dated: January, 2011

SECTION 39 - MANHOLES TABLE OF CONTENTS 39-1 GENERAL PRECAST CONCRETE MANHOLES

CHAPTER 5 SEWAGE PUMPS AND LIFT STATIONS

CITY OF TAMPA WASTEWATER DEPARTMENT TECHNICAL STANDARDS GUIDELINE. FOR CONSTRUCTION OF WASTEWATER FACILITIES July 2014 Version 6

(Condensed from National Electric Code)

SECTION 3.0 SPECIFICATIONS FOR DRINKING WATER DISTRIBUTION SYSTEMS DESIGN

Recovering a Failed Sand Filter Wastewater Treatment System

SPECIFICATIONS - DETAILED PROVISIONS Section Chlorination System (On-site Sodium Hypochlorite Generation System) C O N T E N T S

SECTION FIELD ERECTED INDUCED DRAFT COOLING TOWER

EL DORADO COUNTY REGIONAL FIRE PROTECTION STANDARD

2. A preconstruction meeting with the TWA s staff is required prior to initiating construction.

Residential Sewer Backup Prevention Program

CITY OF GRAND RIVERS LIVINGSTON COUNTY, KENTUCKY

GWINNETT COUNTY DEPARTMENT OF WATER RESOURCES

MASTERSPEC TECHNICAL SPECIFICATIONS DIVISION 22 PLUMBING

Series Sump and Sewage Systems

Facilities Planning Policy & Procedure #20

SECTION SWIMMING POOLS STAINLESS, FULL TILE, OR TILE TRIM

DRINKING WATER PROGRAM POLICY/PROCEDURE KITSAP COUNTY DRINKING WATER ADEQUACY REQUIREMENTS FOR SUBDIVISIONS AND BUILDING SITE APPLICATIONS

Commonwealth of Massachusetts Title 5 Official Inspection Form Subsurface Sewage Disposal System Form - Not for Voluntary Assessments

2010 IDC WATER AND SEWER CONSTRUCTION PACKAGE III 12/11/2009 SAWS WATER JOB. NO /SAWS SEWER JOB NO SOLICITATION #B RA

Homeowner Online Septic System Training (HOST)

SANITARY SEWER FEASIBILITY STUDY AND REPORT NORTH SEBASTIAN AREA

SECTION CROSS CONNECTION CONTROL AND BACKFLOW PREVENTION

Regional District of Okanagan-Similkameen 101 Martin Street Penticton, BC V2A 5J9. November 2008 Project No

STREET LIGHTING. Springville City Power standard street lights will be installed in accordance with Springville City Power's Line Extension Policy.

Sewage Compliance Form Instructions

COMMISSIONERS OF PUBLIC WORKS of the CITY OF CHARLESTON, SOUTH CAROLINA

STORM DRAINAGE CHAPTER 11

SECTION A-A. Control Panel

City of Norwalk. Residential Development Permit Process

SECTION MOTORS AND PUMPS FOR PLUMBING SYSTEMS

f. Sign Installer/Hanger must submit the following to qualify for a license: i. Certificate of Insurance 1. $300,000 Minimum Liability Coverage

UNIFORM DESIGN AND CONSTRUCTION STANDARDS FOR EXTENDING WATER DISTRIBUTION SYSTEMS SECTION 2 DESIGN STANDARDS

A. Product Data shall be provided for each type of product indicated.

Review & Design of the Apia Pressure Sewer System. Presented by Jammie Saena - Samoa Water Authority & Paul Edwards Urban Water Solutions

Fencing, locks on access manholes, and other necessary precautions shall be provided to prevent trespassing, vandalism, and sabotage.

Contact the Jurisdictional Engineer for materials allowed by each jurisdiction.

PROPOSED CONSTRUCTION BUILDING CODES FOR TURF AND LANDSCAPE IRRIGATION SYSTEMS

Bloomington Township Public Water District User Information Packet. Water Service

NORTH HARRIS COUNTY REGIONAL WATER AUTHORITY PIPE HANGERS, Section PIPE HANGERS, SUPPORTS, AND RESTRAINTS

recycle water reuse it save up to from showers & baths for flushing toilets 30% of water use

LAWS AND RULES FOR SEWAGE TREATMENT, AND DISPOSAL SYSTEMS

SECTION SANITARY WASTE INTERCEPTORS

Soil and Site Evaluation for OSS

Read Only Copy Not For Distribution. Chapter 17. Private Potable Water Supply Systems 17.1 GENERAL REGULATIONS 17.2 QUANTITY OF WATER REQUIRED

Content Copy Of Original

Transcription:

DIVISION VI INDIVIDUAL GRINDER PUMP INSTALLATIONS VI-1.000 DESCRIPTION 1.010 General A. Any extension of the Kitsap County sanitary sewer extension shall be completed in accordance with the applicable requirements of the Standards for Sanitary Sewer Extensions, Division I, Section I-4.000, Forms and Agreements. Together with submittal of the individual sewage pump installation plans for approval, the property owner shall also submit a signed copy of the Sewage Pump Installation, Operation, and Maintenance Agreement together with the current recording fee. B. The station s operational components shall be locate at an elevation that is not subjected to the 100 year frequency storm flood and associated wave action, or shall be otherwise adequately protected as certified by a professional engineer registered in the State of Washington. 1.020 Individual Grinder Pump Stations A. Only one grinder pump station is allowed per residence. It will be the responsibility of the homeowner to maintain the grinder station and the forcemain on their property. Areas with up to 10 homes (without further possibility of expanding) shall be served by individual grinder pump stations and shall be reviewed and approved by Kitsap County on a case by case basis. Developments with more than 10 homes will use a commercial pump station maintained by the County. B. It will be the property owner s responsibility to obtain preliminary approval of the concept for their particular situation. Upon preliminary approval, the property owner will be required to submit an engineered plan of the proposed installation showing all pertinent information together with specifications of all materials to be used. VI-2.000 MATERIAL AND CONSTRUCTION VI-1

2.010 General A. The developer shall submit information from the material manufacturer or fabricator showing that the materials meet the requirements of the design and pertinent specifications. The developer shall provide submittals to the County on all materials to be used. 2.020 Pump Station A. The individual sewage pump installation shall consist of a single two horsepower grinder pump, tank, and system controls, valves and piping. B. The grinder pump shall be two horsepower grinder pump designed to grind solids normally contained in domestic and commercial wastes. A pump curve indicating the pump capacity at design head for the pump to be installed shall be included with submittal. C. Tanks shall be either fiberglass, steel with protective coating for underground installations, or concrete meeting the dimensions shown on the standard plan. Tanks shall be watertight. 2.030 Piping and Control Facilities A. System controls shall consist of a higher water alarm light, one circuit breaker per pump, 120V AC control voltage transformer, starters, NEMA 3R enclosure for electrical control circuits which shall be mounted on the building adjacent to the pump unit, three liquid level control floats (pump off, pump on, high water alarm) and necessary wiring and appurtenances for a complete installation. B. The service piping from the pump unit to the county pressure main shall be a minimum of 1 ¼ inch diameter schedule 80 PVC. A minimum burial depth of 24 inches shall be maintained. C. Where a gravity sewer main exists in the public right-of-way, building sewer pressure lines shall discharge into gravity side sewers at the property/easement line as per County Standard Detail. VI-2

VI-3.000 INSTALLATION 3.010 General A. A check valve and a gate valve shall be provided inside the tank with a union or quick disconnect fitting provided for easy removal of the pump. An appropriate size saddle shall be provided where the service line connects to the county pressure main and shall be provided with a corporation stop, check valve and valve box installed over the corporation stop as shown on the County Standard Details. B. No individual sewage pump shall be installed on the discharge side of an existing septic tank. Pumping units shall be connected directly to the building sewer line. VI-4.000 TESTING 4.010 General A. The completed grinder pump station shall be given an operational test of all equipment for leaks in all piping and seals, and for correct operation of the automatic control system and all auxiliary equipment. Developer shall conduct preliminary tests and be assured that the section to be tested is in an acceptable condition before requesting the County to witness the test. B. Only after final testing and acceptance by the County is the grinder pump station allowed pumping sanitary sewage into the County system. VI-3

Return Address: Kitsap County Public Works Mail Stop #27 Senior Program Manager, PW/WW KITSAP COUNTY PUBLIC WORKS WASTEWATER DIVISION Sewage Pump Installation, Operation, and Maintenance Agreement WHEREAS,, hereinafter known as the OWNER", does enter into an agreement with KITSAP COUNTY, hereinafter known as the "COUNTY", on this day of,, for the project known as the INDIVIDUAL PUMP SYSTEM. WHEREAS, Owner is possessed of certain real property located at the following address, and legally described as follows: Qtr: Qtr: Section: Township: Range: Plat or Short Plat: Tax Parcel No.: and is within the area served by Kitsap County sewer system, and, WHEREAS, the sewer trunk line is at an elevation adjacent to the real property of Owner that it cannot be served by gravity and necessitates the use of a sewer pump, and WHEREAS, Owner agrees with the County to install an approved pump according to specifications of the County and to keep and maintain said pump and associated equipment in good working order. In the event repairs and maintenance of said pump and associated equipment is required of the County for any reason whatever not the fault of the County, the reasonable cost of said work shall be charged back against the Owner and may become a lien upon said real property. The parties understand the foregoing, and do now therefore AGREE: 1. That Owner shall furnish and install approved sewer pump and associated equipment according to specifications and subject to installation approval of the County. KCPWFORM 4318 IF-2.130 (REV3/08)

2. That said pump and associate equipment shall be maintained in operating condition by the Owner and in the event the County is called upon to maintain, repair or replace said pump or associated equipment, said County may charge back the cost of said work performed, it being the understanding that the total cost of installation, maintenance and operation of said pump and associated equipment shall be at the risk of Owner. This agreement shall bind the Owner, his heirs or assigns of said property and is designed to hold the County harmless. EXECUTED this day of,. Owner STATE OF WASHINGTON) ss) COUNTY OF KITSAP) I certify that I know or have satisfactory evidence that signed this instrument, on oath, and acknowledged it to be his/her free and voluntary act for the uses and purposes mentioned in this instrument. SUBSCRIBED AND SWORN before me this day of,. NOTARY PUBLIC Title: Residing at:. My appointment expires:. KCPWFORM 4318 IF-2.130 (REV3/08)