A range of popular roof shades Spruce Acrylic Roof cannot be tinted.

Similar documents
White, a range of ready-mixed colours, and colours from the Dulux Colour System

DULUX INTERIOR LUXURIOUS SILK TECHNICAL DATA SHEET Version SEPTEMBER THIS ISSUE SUPERSEDES ALL PREVIOUS PUBLICATIONS

DULUX WEATHERGUARD FINE TEXTURED

Approx. 12 m² per litre depending on surface porosity, profile. Application methods

TECHNICAL DATA SHEET

NC Sanding Sealer Clear Clear Nitrocellulose Sanding Sealer

Property Test/Standard Description

TECHNICAL DATA SHEET

DULUX BEST PAINTING PRACTICE

Product Data Sheet Waterproofing Membrane for Ponds and Water Features Description Uses Suitable Surfaces Additional Uses Specification

FEATURES AND BENEFITS

Product Information CHEMGLAZE B 9942 A/B. Coating for Casting Pits. Easy Application Chemglaze B 9942 A/B will bond to damp and wet surfaces.

For detailed product information, visit our DeckOver, Textured DeckOver or Extra Textured Deckover product pages.

Property Test/Standard Description

Property Test/Standard Description

Property Test/Standard Description. US EPA method 24 (tested) (CARB(SCM)2007, SCAQMD rule 1113, Hong Kong)

Approved. Property Test/Standard Description. matt (0-35) Flash point ISO 3679 Method C calculated VOC-US/Hong Kong. US EPA method 24 (tested)

Normadur 65 HS. Technical Data PROPERTIES AND RECOMMENDED USAGE TECHNICAL DATA

Property Test/Standard Description. US EPA method 24 (tested) (CARB(SCM)2007, SCAQMD rule 1113, Hong Kong)

ASTEC ANTI-GRAFFITI CLEAR COATING POLYURETHANE SILICONE MODIFIED TYPE. Aliphatic 2 Pack Polyurethane Anti-graffiti coating. PRODUCT DESCRIPTION

Property Test/Standard Description

TECHNICAL DATA SHEET

DESCRIPTION FEATURES AND BENEFITS AREAS OF USE. DiamondCoat Polyurethane Concrete Floor Finish is suitable for use in the following areas:

Pre-qualification testing in accordance with NORSOK M-501, Rev. 5, System 1, suitable for exterior exposure in offshore environment, below 120 C.

Tested in accordance with ISO , high expected durability in corrosivity category C5-I. Property Test/Standard Description

Property Test/Standard Description. semi gloss (35-70) Flash point ISO 3679 Method 1

Approved. Property Test/Standard Description. high gloss (85+) Flash point ISO 3679 Method 1 30 C. US EPA method 24 (tested)

Approved. Property Test/Standard Description. matt (0-35) Flash point ISO 3679 Method F (29 C) calculated VOC-US/Hong Kong

^(ValidationDate) AE - BH - DZ - EG - KW - LY - MA - OM - QA - SA - TR Jotashield Tex Ultra

THE BRITE THING TO DO

Approved. Property Test/Standard Description. matt (0-35) Flash point ISO 3679 Method F (29 C) calculated VOC-US/Hong Kong

Property Test/Standard Description

Ganicin 2.8 ZR-E Zinc-Rich Epoxy Primer

Refer to Substrates & Surface Preparation.

Property Test/Standard Description. US EPA method 24 (tested) (CARB(SCM)2007, SCAQMD rule 1113, Hong Kong)

PRODUCT DATA SHEET Sika Unitherm Platinum

Technical Data Sheet

GRIP-GARD PLUS BRUSH / ROLL ADDITIVE

Property Test/Standard Description

Technical Data Jotamastic 80 MIO

Ganicin 2.8 ZR- U Zinc-Rich Polyurethane Primer

- Aromatic hydrocarbons - Binder 2,67 kg/dm³ (±0,06 Kg/dm³) Solid content - 80% by weight (±2%) - 58% by volume (±2%) according to ASTM D2697

Property Test/Standard Description

Property Test/Standard Description. semi gloss (35-70) Flash point ISO 3679 Method 1 32 C

Property Test/Standard Description

Approved. Property Test/Standard Description. gloss (70-85) Flash point ISO 3679 Method 1 25 C calculated VOC-US/Hong Kong. US EPA method 24 (tested)

Approved. Property Test/Standard Description. gloss (70-85) Flash point ISO 3679 Method 1 32 C calculated VOC-US/Hong Kong. US EPA method 24 (tested)

One-component, heat-resistant silicone acrylic topcoat primarily for the PPG HI-TEMP 1027 primer or the PPG HI-TEMP 222 G primer

AQUATITE. Also designed as: Crack/gap filler for masonry and unglazed ceramics Sealants against leaks Repairer for roof cracks and gutters

Property Test/Standard Description

SIGMACAP MASTIC GF. September surface tolerant coating for lower grade of steel preparation

Matte Volume Solids 80 ± 2% (ISO 3233:1998) VOC. Overcoating Data 10ºC 25ºC 35ºC Min. 10 hours 4 hours 3 hours Max. 6 months 6 months 6 months

SIDER-POOL. Product Data. Features and Uses

The Application Guide offers product details and recommended practices for the use of the product.

Approved. Property Test/Standard Description. gloss (70-85) Flash point ISO 3679 Method C VOC-US/Hong Kong. US EPA method 24 (tested)

Product Information. DiamondCoat Polyurethane Concrete Floor Finish Clear, high build, high abrasion resistant, decorative concrete floor coating

Carboguard 890 PRODUCT DATA SHEET SELECTION & SPECIFICATION DATA. Generic Type. Cycloaliphatic Amine Epoxy

ELASTOFLEX ELASTOMERIC TEXTURED ACRYLIC WALL COATING SPECIFICATION

Measured in accordance with ASTM D 2697.

Corlar LV PR 178 Series Epoxy Primer

Dulux AcraTex Roof Sealer SB Clear

Property Test/Standard Description

Construction. Pulastic Coating-221 W. 2 Component Polyurethane

Technical Data Sheet EPOXY PRIMER 3:1 Anti-corrosion epoxy primer RELATED PRODUCTS. Epoxy primer hardener EPOXY PRIMER HARDENER PROPERTIES

SikaCor 255 Epoxy-binder for mortars on concrete and steel. Protective Coatings

Refer to Substrates & Surface Preparation.

Aliphatic Acrylic-Polyester Polyurethane

YEARS WATER PROOFING AND PERFORMANCE WARRANTY*

January 2007 Product Information ENVIROBASE HIGH PERFORMANCE

Flooring and Bedding. RonaFloor SL. Self-smoothing seamless epoxy resin flooring system

two component high build amine adduct cured phenolic epoxy primer

APPLICATION GUIDELINES EXTERIOR DECK SYSTEM

1.4 kg/l (11.4 lb/us gal) Maximum 295 g/kg (Directive 1999/13/EC, SED) Maximum 420 g/l (3.5 lb/gal) 50 to 63 μm (2.0 to 2.

PPG HI-TEMP 1000 V (AMERCOAT 873) PRODUCT DATA SHEET December 10, 2014 (Revision of June 30, 2014) DESCRIPTION

The Application Guide offers product details and recommended practices for the use of the product.

Approved. Property Test/Standard Description. matt (0-35) Flash point ISO 3679 Method 1 25 C calculated VOC-US/Hong Kong. US EPA method 24 (tested)

Corlar 2.1 PR-P High Solids Productive Epoxy Primer For Use With FG-040, FG-041 or FG-042 Activators

Date of issue: 5 October 2017 Page: 1/6

The Application Guide offers product details and recommended practices for the use of the product.

PORTER S ORIGINAL LIME WASH

Application. Fuselage Fuselage Fuselage. Decoration Decoration

1.4 kg/l (11.4 lb/us gal) Maximum 272 g/kg (Directive 1999/13/EC, SED) Maximum 420 g/l (3.5 lb/gal) To 650 C (1200 F) To 538 C (1000 F)

Application Guide HI-TEMP 1027 APPLICATION GUIDE. Number: AG-3001 Revision: Page 1 of Introduction. 2. Where to apply Hi-Temp 1027

This product contributes to the Green Buildings Standard credits. Please see section Green Building Standards. Property Test/Standard Description

3MTM FireDamTM Intumescent Coating WB Installation Manual. Thinner is. Better

SECTION High Performance Coatings Field Applied Acrylic Urethanes (Solid Color, Pearl and Metallic Finishes)

DP4101 / DP4104 / DP4107 HS PRIMER

Dulux AcraTex Acraprime Water Based

Corlar 2.1 PR-P High Solids Productive Epoxy Primer

Property Test/Standard Description. gloss (70-85) Flash point ISO 3679 Method C VOC-EU EU VOC Directive 2004/42/CE (theoretical) 14 g/l

Diescolith SOL-Silikat

PRODUCT SELECTION GUIDE

Aviox CF Primer 37124

TECHNICAL DATA SHEET

Basecoat WB Technical Data Sheet 09 / 05 / 2016 L UK & Ireland Basecoats

HYDRAULIC GATE SEALS. Industrial Rubber Supply (1995) Ltd.

vinyl ester Property Test/Standard Description semi gloss (35-70) Flash point ISO 3679 Method 1 34 C calculated IED (2010/75/EU) (theoretical)

Aerodur CF Primer 37047

High Gloss Wet Look Lacquer

What is Dulux Professional DryErase?

Transcription:

TECHNICAL DATA SHEET Version 1 2017 MARCH THIS ISSUE SUPERSEDES ALL PREVIOUS PUBLICATIONS PRODUCT DESCRIPTION A quality, 100% pure acrylic paint for roofs PRODUCT USES Spruce Acrylic Roof is for application to suitably primed galvanised iron, fibre cement and cement roof tiles. Although a roof paint, it can also be applied to other areas such as side cladding, galvanised iron garage doors, gutters, downpipes and cement garden pots. FEATURES AND BENEFITS Pure Acrylic weather protection. Good adhesion to roofs. Durability against roof temperature fluctuations. UV and Weather resistant. Easy water clean-up. PRODUCT INFORMATION Appearance Colour Binder Type Matt A range of popular roof shades Spruce Acrylic Roof cannot be tinted. Pure Acrylic Density at 23 C Approx. 1.28 Solids Content By weight: Approx. 45%. By volume: Approx. 31% Packaged Viscosity Viscosity at 23 C: Approx. 110 KU Spreading Rate Approx. 7-8m² per liter on non-porous surfaces, depending on surface profile and application method. Approx. 4-5m² per liter on porous surfaces, depending on surface profile and application method. Recommended DFT per coat Min. 40µm. Max. 45µm. Recommended WFT per coat Min. 130µm. Max. 145µm. Flash Point Non-flammable

APPLICATION INFORMATION Mixing Stir until homogeneous with a flat paddle. Application Surface Conditions Surface Temperature between 10 C - 35 C. Relative Humidity between 10 % 85 % OR 2 C above dew point minimum Application Methods Brush or roller or spray application For airless spray application, the suggested Airless Spray Tip is 0.017-21 at 150 200 Bar. Thinner Thinning not recommended, however a thinned coat to a maximum of 10% with water will act as a primer coat and will need to be followed up with 2 undiluted coats of Spruce Acrylic Roof. Drying Time Touch dry 1 hour. Recoating Time 4 hours (Drying times will be extended during cold, wet or humid conditions.) Cleaning of Equipment Substrates Precautions: Coats Required After use, remove as much product as possible, and then clean immediately with water. Cement roof tiles galvanised iron and fibre cement. Other applications include side cladding, galvanised iron garage doors, gutters and downpipes. Do not apply directly to galvanised iron surfaces. Not designed for application to flat roof surfaces. Not suitable for direct application to powdery or friable surfaces whether previously painted or not. Spruce Acrylic Roof is not recommended for application to Chromadek roof sheeting or Galvanised Iron roof sheeting with insulation board OR Clay, Slurry coated tiles and slate. Under no circumstances should Dulux Trade Corrocote 3 or another Manufacturer s Water Based Etch Primer be used as a primer for this product on galvanised iron roofs. Apply two to three finishing coats to new and previously coated surfaces to achieve a closed film and solid colour. The quantity of paint required can be obtained by measuring the floor area of the house covered by the roof, including overhang. Additional allowance of + 30% must be made for the pitch of the roof, plus approx. 30% for the corrugated profile. Divide the total area by the spreading rate of the paint (see Product Information) to give an indication of the paint requirements per coat. Make allowance for thinning of the primer coat. Page 2 of 6

SURFACE PREPARATION Ensure that surfaces are sound and free from dust, oil, grease, dirt, and debris. Surfaces must be thoroughly dry - no more than 12% moisture content. NEW SURFACES Galvanised Iron (new, un-weathered) Heavy fabricator s pre-treatment oil, and other surface contaminates must be removed with Dulux Galvanised Iron Cleaner. A water-break free surface indicates thorough cleaning - running water should not form droplets. Prime with one full coat of Dulux Galvanised Iron Primer Galvanised Iron (unpainted, weathered) Remove all loose rust and white scale by means of wire brushing, sanding, chipping, or mechanical scouring - down to bright metal. To remove dirt, salts and zinc corrosion (white rust) clean thoroughly with Dulux Galvanised Iron Cleaner achieving a waterbreak free surface. Areas showing red rust must be removed back to bright galvanised iron spot primed with Dulux Galvanised Iron Primer followed by one full coat of the same primer. Galvanised Iron in aggressive/coastal conditions Remove all loose rust and scale by means of wire brushing, sanding, chipping, or mechanical scouring - down to bright metal. To remove dirt, salts and zinc corrosion (white rust) clean thoroughly with Dulux Galvanised Iron Cleaner. Apply two full coats of Dulux Galvanised Iron Primer. Cement and Fibre Cement Roof Tiles (new) To remove dust, debris and chalky residue, wash the entire roof area using highpressure washing, using a rotating nozzle at a pressure between 150 and 200 bar. Alternatively, scrub the entire roof area with a bristle brush, using water from a garden hose and allow drying. For sound cement roof tiles; prime with one coat Spruce Acrylic Roof, thinned up to 10% with water to aid absorption followed by 2 undiluted coats of Spruce Acrylic Roof. For very porous/slightly friable/chalky cement tiles and all fibre cement tiles; prime with Dulux Bonding Liquid and overcoat within 48 hours with 2 coats Spruce Acrylic Roof. Page 3 of 6

SURFACE PREPARATION NEW SURFACES Cement and Fibre Cement Roof Tiles (weathered, unpainted) To remove dust, debris and chalky residue from cement roof tiles, wash the entire roof area using high-pressure washing, using a rotating nozzle at a pressure between 150 and 200 bar. Alternatively, scrub the entire roof area with a bristle brush, using water from a garden hose. Old, weathered fibre cement is porous and may encourage the growth of fungus. Scrub these areas with either of the following solutions: 25% chlorine solution and water or 25% sodium hypochlorite and water solution. Rinse off thoroughly, removing residues of the cleaning solution, and at the same time cleaning off dust and debris from the roof. For sound cement roof tiles; prime with one coat Spruce Acrylic Roof, thinned up to 10% with water to aid absorption followed by 2 undiluted coats of Spruce Acrylic Roof. For very porous/slightly friable/chalky cement tiles and all fibre cement tiles; prime with Dulux Bonding Liquid and overcoat within 48 hours with 2 coats Spruce Acrylic Roof. Waterproofing. Were required apply at least three coats Dulux Rainshield over the primer coat, recommended minimum waterproofing dry film thickness of 1000μm. Overcoat with 2 coats Spruce Acrylic Roof. PREVIOUSLY PAINTED SURFACES Galvanised Iron Perform adhesion tests on the existing coating to cross cut test ISO 2409-2013 standards. Remove lose roof paint back to a sound surface and/or bare galvanised iron. For Galvanised Iron in poor condition, strip completely. Remove all loose rust and scale by means of wire brushing, sanding, chipping, or mechanical scouring - down to bright metal. To remove dirt, salts and zinc corrosion (white rust) clean thoroughly with Dulux Galvanised Iron Cleaner achieving a waterbreak free surface. For sound surfaces scrub the area with Dulux Pre-Paint Sugar Soap/water solution. Clean with high pressure water jet to remove Dulux Pre-Paint Sugar Soap residue and other surface contaminates. Apply two full coats of Dulux Galvanised Iron Primer to all exposed galvanised iron. Page 4 of 6

SURFACE PREPARATION PREVIOUSLY PAINTED SURFACES Cement and Fibre Cement Roof Tiles Perform adhesion tests on the existing coating to cross cut test ISO 2409-2013 standards To remove dust, debris and chalky residue and lose paint from cement roof tiles, wash the entire roof area using high-pressure washing, using a rotating nozzle at a pressure between 150 and 200 bar. Alternatively, scrub the entire roof area with a bristle brush, using water from a garden hose. Cement and Fibre Cement Roof Tiles in poor condition, strip completely. Old, weathered fibre cement is porous and may encourage the growth of fungus. Scrub these areas with either of the following solutions: 25% chlorine solution and water or 25% sodium hypochlorite and water solution. Rinse off thoroughly, removing residues of the cleaning solution, and at the same time cleaning off dust and debris from the roof. For sound cement roof tiles; prime with one coat Spruce Acrylic Roof, thinned up to 10% with water to aid absorption followed by 2 undiluted coats of Spruce Acrylic Roof. For very porous/slightly friable/chalky cement tiles and all fibre cement tiles; prime with Dulux Bonding Liquid and overcoat within 48 hours with 2 coats Spruce Acrylic Roof. Waterproofing. Were required apply at least three coats Dulux Rainshield over the primer coat, recommended minimum waterproofing dry film thickness of 1000μm. Overcoat with 2 coats Spruce Acrylic Roof. GUARANTEE Dulux offers a 7-year product guarantee on Spruce Acrylic Roof (white and standard colours). Spruce Acrylic Roof when tinted is not guaranteed, as Dulux does not offer tint bases in the Spruce Acrylic Roof range. To register your guarantee, simply call the Dulux Technical Helpline within 30 days of purchase. Simply supply your contact details, the site details, purchase details, batch number and related products used. You will receive a Guarantee Reference Number that you should record and keep in a safe place, together with your purchase slip for future reference. For terms and conditions of the guarantee, please visit www.duluxguarantee.co.za or contact Dulux Technical Helpline 0860 330 111. Page 5 of 6

HEALTH AND SAFETY INFORMATION This product contains no added lead. Avoid contact with skin or eyes. Keep out of reach of children. If accidently swallowed, seek medical advice immediately and show this container to the doctor. Dry sanding, flame cutting and/or welding of the dry paint film will give rise to dust and/or hazardous fumes. If exposure cannot be avoided by the provision of local exhaust ventilation, suitable respiratory protective equipment should be used. Do not empty into drains or watercourses. Ensure good ventilation during application and drying. It is recommended to use suitable protective clothing and equipment. To avoid the risk of spillage, always store and transport containers in a secure upright position. Refer to Material Safety Data Sheet for complete information. ADDITIONAL INFORMATION Packaging Storage Conditions Disclaimers 5lt, 20Lt Store under cool dry conditions away from direct sunlight, heat and extreme cold. Colour references are as accurate as modern printing will allow. Among others, the following factors may affect final colour appearance: product sheen and texture, colour and light reflections, application, surface texture and preparation. For best colour and sheen consistency, it is advisable to use containers of the same batch number, or to mix different batches together in a large container, or to finish in a corner before starting a new container. TDS STANDARD DISCLAIMER The recommendations contained herein are given in good faith and meant to guide the specifier or user in accordance with good painting practices. They are gained from our tests and experiences and are believed to be accurate and reliable. No warranty/guarantee is implied by the recommendations contained herein since the conditions of use; application method, substrate and cleanliness of the substrate are beyond Dulux control. Important Note; Technology may change with time, necessitating changes to this Technical Data Sheet (TDS). It is the responsibility of the user to ensure that the latest TDS is being used for reference. Dulux Technical Data Sheets are available on our website www.dulux.co.za or please contact: Dulux On-Line on 0860 330 111. Email ZA.Helpline@akzonobel.com ICI Dulux (Pty) Ltd is part of AkzoNobel. ICI Dulux (Pty) Ltd Reg No.1946/020769/07 Page 6 of 6