A. This Section provides information regarding vapor permeable roof underlayment for the exterior roof.

Similar documents
A. Source Limitations: Obtain each type of building insulation through one source.

SECTION 07530CP EPDM MEMBRANE ROOFING

SECTION MODIFIED BITUMINOUS MEMBRANE ROOFING Peel & Roof

E. Section Polymer Modified Cement Waterproofing. K. Section Sub drainage: Foundation perimeter drainage.

ROOFING CONTRACTORS GENERAL TRADE KNOWLEDGE EXAMINATION CONTENT INFORMATION

DuPont Tyvek Air Barrier Installation Guidelines. Canadian Version. Version 2

SECTION THERMOPLASTIC POLYOLEFIN (TPO) ROOFING PART 1 - GENERAL 1.1 RELATED DOCUMENTS

INSTALLING WATER-RESISTIVE BARRIERS & FLASHING

MASTERFORMAT SPECIFICATION

SECTION FLUID-APPLIED VAPOR PERMEABLE MEMBRANE AIR BARRIER SYSTEM ASSEMBLY (August 2013)

SECTION A. ACSE 7 Minimum Loads for Buildings and other Structures.

City of Republic Community Development Department. Residential Roofs REVISION DATE: JANUARY 2017

SECTION SLOPED TRANSLUCENT METAL SKYLIGHT SYSTEM

A. The work of this section includes, but is not limited to, the following:

PLATON RUGGED, DIMPLED HIGH-DENSITY POLYETHYLENE (HDPE) MEMBRANE THAT KEEPS FOUNDATIONS AND FLOORING DRY ADVANCED TECHNOLOGY EASY INSTALLATION

DuPont. Tyvek Sheathing Membrane Installation Guidelines. Version 2. Canadian Version

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION SECTION: WATER-RESISTIVE BARRIERS/WEATHER BARRIERS

SLATE ROOFING INSTALLATION PROPOSAL [Last updated 10/08/2017]

1. Decks, balconies, and sun porches 2. Walkways, ramps, and stairways 3. Patios and courtyards

ICC-ES Report OR-4, AND MOISTURE DIVISION: SECTION: SECTION: Reissued 11/2017 This. Report Holder:

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: RIDGE VENTS REPORT HOLDER: VERSCENE, INC.

Section Pre-Applied Sheet Membrane Waterproofing

Eclipse Energy Guard. Product Information & Installation Manual General Installation Requirements

Light-Metal Roof Edge, Raised

EcoTouch Insulation with PureFiber Technology

A. Meet at Project site <insert number> days before starting installation.

SECTION PRE-ENGINEERED BUILDING INSULATION

Weatherproofing & Sealing Systems

Recommended Design Considerations. and. Guide Specifications For. Commercial Building Insulation

INSTALLATION GUIDE.

SINGLE FAMILY USER S BULLETIN FOR INSTALLATION OF DUPONT WEATHERIZATION SYSTEMS PRODUCTS

(Project Location) (your firm's name)

Pacific Tile Counter Batten and Batten

Magnum Board Section Digicon Information Inc. Page 1

SECTION CONCRETE ROOF TILE

SECTION COLD APPLIED RUBBER MODIFIED ASPHALT WATERPROOFING

GOWANDA, NEW YORK SEPTEMBER 18, 2008 ARCH PROJECT NO

Metafor Panel System Installation Guide

ALLMET CONTINENTAL INSTALLATION GUIDE

SECTION REFLECTIVE-FACED, MASONRY CAVITY WALL INSULATION

ROOF ASSEMBLIES CHAPTER 9

Colphene BSW Training and Application Guide. Colphene BSW Waterproofing Membrane. 1. Prepare substrate

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: COMPOSITE RUBBER SHAKES REPORT HOLDER: DAVINCI ROOFSCAPES, LLC

Henry Self-Adhering Roofing Underlayments. self-adhering. roofing underlayments DESIGNED FOR: Shingles. Tile. Metal. Slate

ROOFING APPLICATION STANDARD (TAS) No. 102(A)-95

SECTION ELASTOMERIC MEMBRANE ROOFING

Installation instructions Thin, flexible multi-foil insulation

TECHNICAL INFORMATION

EVALUATION REPORT Boral Roofing 7575 Irvine Center Drive Suite 100 Irvine, CA

Air and Vapor Barrier 3015

ALLNEX DAMP PROOF AND TANKING MEMBRANES. Product. Scope. Appraisal No. 805 [2013] Appraisal No. 805 (2013) Amended 26 January 2018.

MIAMI-DADE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER)

Trusted ICC ES DIVISION: ATLANTA, CGF PRO, ENERGYS. Look. Conformity! Evaluation. ICC-ES Evaluation

REPORT HOLDER: THE DOW CHEMICAL COMPANY 1501 LARKIN CENTER DRIVE MIDLAND, MICHIGAN EVALUATION SUBJECT:

J41 Reinforced bitumen membrane roof coverings

Installation Instructions - Roofs

OREGON ROOF CONSULTING - ROOF INSPECTION FORM

INSULATION OWENS CORNING INSULATION PRODUCTS IN THIS SECTION:

Residential Building Inspections

The better way to build TM. Installation Manual FOUNDATION SIPs & FROST WALLS SIPs

SPECIFICATION GUIDELINE

ITEM 458 WATERPROOFING FOR STRUCTURES

SECTION CONCRETE TILE ROOFING. A. Section Includes: Concrete tile roofing as shown on Drawings and as specified.

Reflective Insulation Specification & Application Guide for Post Frame and Metal Building Construction

2018 British Columbia Building Code Public Review of Proposed Changes

ROOF ASSEMBLIES CHAPTER 9

Master Specification SECTION 02621

Senergy Platinum CI Stucco Typical details for an impact resistant cement plaster stucco system featuring Neopor GPS Plus Rigid Insulation Board

ThermaCal Nail Base Roof Insulation Panels (all versions) Installation Instructions

CITY OF CITRUS HEIGHTS BUILDING & SAFETY DIVISION

TEST PROCEDURE FOR AIR PERMEABILITY TESTING OF RIGID, DISCONTINUOUS ROOF SYSTEMS

SECTION COMPOSITE METAL WALL PANEL SYSTEM (Accu-Trac Low Profile DS)

Lamit Industries, Inc. 710 Marion Road Columbus, Ohio P-(614) F-(614)

REPORT HOLDER: R.L. ADAMS PLASTICS, INC CROSSROADS COMMERCE PARKWAY WYOMING, MICHIGAN EVALUATION SUBJECT: POLYCORE BRAND INSULATION

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: REFLECTIX INCORPORATED

SECTION MANUFACTURED ROOF EXPANSION JOINTS

REPORT HOLDER: RARE MANUFACTURING INC A AVENUE SURREY, BRITISH COLUMBIA V4N 4P2 CANADA EVALUATION SUBJECT: IRONWOOD SHAKE

ENKASONIC FLOOR UNDERLAYMENT 9110

application instructions

REPORT HOLDER: FEROOF CO., LTD SEONWON LI SEONNAM MYEON SUNGJU GUN KYEONGSANGBUK DO SOUTH KOREA EVALUATION SUBJECT:

Floor Insulation Underlayment Section Sound Control Matting

SECTION SHEET MEMBRANE WATERPROOFING AND CRACK ISOLATION

PLATON FOUNDATION WRAP

THE THERMAKRAFT ONE WRAP SYSTEM. Product. Scope. Appraisal No. 962 [2017] Appraisal No. 962 (2017) BRANZ Appraisals

Sarnavap 1000E is an unsupported vapour control layer based on PE-LD (Low Density Polyethylen).

Magnum Board Section Digicon Information Inc. Page 1

A. Product Data: Submit manufacturer s product data, with complete general and specific installation instructions, recommendations, and limitations.

SECTION MODIFIED BITUMINOUS SHEET WATERPROOFING

A Closer Look Inspection Service 2015 IECC Residential DFW area handout

EMPIRE SHAKE, EMPIRE PLUS SHAKE, AND EMPIRE SLATE POLYOLEFIN COMPOSITE TILES

PROJECT LOCATION SECTION COPPER METAL PLATE WALL PANELS

Standard specification for the application of Danosa Two-Layer waterproof roofing membrane to plywood & concrete surfaces.

Roof Replacement. Notes: T-1 (Title Sheet) Roof Key Plan Russell House Student Union 1400 Greene Street Columbia, South Carolina 29208

APPLICATION INFORMATION FOR RESIDENTIAL ROOFING AND RESIDENTIAL ROOFING PACKET

EXCEL Medical Waste - Equipment Installation Section SECTION GYPSUM BOARD

SPECIFICATION GUIDELINE

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: METAL ROOF PANELS SECTION: ROOF PANELS REPORT HOLDER: ROSER CO., LTD.

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017

J41 Reinforced bitumen membrane roof coverings

Transcription:

DELTA -VENT S Vapor Permeable (Breathable) Roof Underlayment Division 7 Thermal and Moisture Protection PART 1 GENERAL 1.1 SUMMARY A. This Section provides information regarding vapor permeable roof underlayment for the exterior roof. B. Related Sections include the following: 1. Division 6, Section Rough Carpentry for exterior sheathing. 2. Division 7, Section Clay Tile for roof assembly. 3. Division 7, Section Slate Tile of roof assembly. 4. Division 7, Section Concrete Tile for roof assembly. 5. Division 7, Section Wood Shakes and Shingles for roof assembly. 6. Division 7, Section Metal Roofing for roof assembly. 1.2 REFERENCES A. AATCC Test Method 42-2000 Water Resistance (Impact Penetration Test). B. CAN/CGSB-4.2 No 26.3 Resistance to water penetration. C. ASTM E96 Water Vapor Transmission of Materials. 1.3 SUBMITTALS A. Product Data: Include manufacturer s written instructions, technical data, and tested physical and performance properties of vapor permeable underlayment. B. Shop Drawings: Provide 1-1/2 scale drawings (or larger) showing relationship of underlayment to: 1. Framing or blocking member 2. Batten boards 3. Metal decking 4. Thermal insulation 5. Sheathing 6. All roofing, fascia and gable end conditions 7. Roof or attic ventilation penetrations 8. Roof curbs 9. Pipe, conduit and duct penetrations C. Samples: 1. 3 x 5 (76.2 mm x 126 mm) sample of vapor permeable underlayment membrane 2. Single sided sealing tape, compatible to underlayment 3. Rubberized (permanently elastic) caulking adhesive, compatible to underlayment 4. Provide materials and fasteners for mock-up as specified in Section

D. Manufacturer s Instructions: Provide manufacturer s instructions showing the recommended procedures and sequences of installation of vapor permeable underlayment. 1.4 QUALITY ASSURANCE A. Underlayment manufacturer shall have an on-going quality control program with inspections by a nationally recognized independent organization. DELTA -VENT S is listed with Quality Auditing Institute (www.qai.org). B. Source Limitations: Obtain all vapor permeable underlayment through one source from a single manufacturer. C. Pre-installation meeting: Conduct meeting at project site to comply with requirements in Division 1, Section Project Management and Coordination. Review requirements for underlayment, including surface preparation specified under other sections, substrate condition and pre-treatment, forecasted weather conditions, special details and flashings, installation procedures, testing and inspection procedures, protection, and repairs. 1.5 DELIVERY, STORAGE, AND HANDLING A. Deliver materials to project site in original containers with seals unbroken, wrapped in a polyethylene sleeve, labelled with manufacturer s name, and product brand name. B. Store rolls under cover, on a clean, level surface, either flat or upright PART 2 PRODUCTS 2.1 MANUFACTURERS A. Products: Subject to compliance with requirements, provide one of the following products: 1. Spun Bonded Polypropylene with embedded breathable film: Underlayment shall be furnished in standard rolls of 1.5m wide by 50m long. a. DELTA -VENT S, distributed by Cosella-Dörken Products, Inc. Phone: +1 (888) 433-5824 - www.deltavents.com b. Others as may be approved by Addendum. Note: The Architect is not aware of any other material that has the water penetration resistance and high vapor permeability of the specified product. 2.2 UNDERLAYMENT PHYSICAL PROPERTIES A. Three layer synthetic underlayment consisting of polypropylene spun fiber non-woven inner and outer layers and a polypropylene film center layer B. Weight: 2.9 lbs / 100 ft 2 (140g / m²) C. Water Penetration Resistance: CAN/CGSB-4.2 NO 26.3: 252 (642 cm) D. Water Vapor Transmission: ASTM E96, Proc. B: 120 grains/h/ft²/in Hg (perms) E. Water Impact Penetration Resistance: AATCC 42-2000: 0 g (pass) F. Flame Spread: ASTM E84-09: 25 (NFPA Class A) G. Smoke Developed: ASTM E84-09: 105 2.3 BUILDING CODE APPROVAL A. ICC ES AC188, Acceptance Criteria for Roof Underlayment B. ICC-ES AC 48, Acceptance Criteria for Use in Severe Climate Areas

C. CSA 220.1-06 Installation of Concrete Roof Tiles 2.4 AUXILIARY MATERIALS A. Single-Sided Tape: a. DELTA -MULTI-BAND, to seal DELTA -VENT S at overlaps, penetrations, and to repair tear damage; distributed by Cosella-Dörken Products, Inc. b. DELTA -FLEXX-BAND, to seal DELTA -VENT S at inner and outer connections to structural details or penetration, and to repair tear damage; distributed by Cosella-Dörken Products, Inc. B. Rubberized Caulking Adhesive (permanently elastic): a. DELTA -THAN, to seal DELTA -VENT S at overlaps; distributed by Cosella-Dörken Products, Inc. C. Fasteners: a. Roofing nails minimum 1 long, with plastic or metal cap (1 diameter). D. Flashing: a. DELTA -MULTI-BAND and DELTA -FLEXX-BAND can be used as flashing to ensure a water-tight seal until roofing and counter-flashing is completed. PART 3 EXECUTION 3.1 EXAMINATION A. Examine substrates, areas, and conditions, with installer present, for compliance with requirements and other conditions affecting performance. 3.2 SURFACE PREPARATION A. Clean and prepare substrate according to manufacturer s written recommendations. Provide clean and solid substrate for vapor permeable underlayment application. 3.3 PENETRATIONS A. Pipes and conduits: 1. Install manufactured penetration sleeves sized for the penetration and install as recommended by the manufacturer. 2. Unroll DELTA -VENT S membrane next to penetration and fold membrane back on itself. Mark and cut out penetration size out of membrane. Ensure cut out section is slightly smaller than diameter of penetration. Slide membrane over penetration. 3. Wrap DELTA -MULTI-BAND or DELTA -FLEXX-BAND around penetration. Ensure that 2 extend onto the membrane, as well as on to the penetrating subject. B. Large, curbed roof penetrations: 1. Follow roof manufacturer s and curb manufacturer s approved shop drawings for curb and roof system installation. 2. Unroll and install DELTA -VENT S around curb. Run membrane 6 up on sides of curbs, or to top if less than 6. 3. Using DELTA -MULTI-BAND seal all laps (joints) and corners together (see standard details). 3.4 VAPOR PERMEABLE UNDERLAYMENT APPLICATION

1. DELTA -VENT S is installed on the cold side of the roof assembly, below the Tile, Slate, or Metal roofing material. 2. DELTA -VENT S should be installed label side up, laid such that it forms a continuous membrane over the entire roof area, allowing any water to drain down to the gutters. Avoid blockages that would otherwise obstruct the water flow. 3. DELTA -VENT S should be fully supported to give a clear drainage path.* 4. Draping between batten boards may result in ponding, and should be avoided. If this is not practical on low slope roofs then the laps must be sealed with DELTA - THAN to prevent leakage. 5. Minimum 1 roofing nails with a minimum 1 plastic or metal cap may be used to fasten DELTA -VENT S; temporary roofing nails may be used along top and bottom edge of underlayment if vertical battens are used over the DELTA -VENT S. Ensure compatibility between fasteners and roofing material. 6. Appropriate precautions should be taken during installation in high winds. 7. At eaves, ensure that DELTA -VENT S is dressed into the gutter. 8. It is recommended to seal all vertical laps with DELTA -MULTI-BAND or DELTA - THAN. The vertical and horizontal lap width should be determined using the chart below. 9. When roof slopes are lower then 10º, we recommend a continuous bead of DELTA -THAN in the laps. 10. In severe climates it is recommended to install a self adhering membrane at the perimeter of the roof as required per IBC (International Building Code). 11. DELTA -VENT S should be laid horizontally across the rafters, starting at the eaves and secured in place. 12. When partially supported between battens, it is good practice to introduce an extra batten 1 above the bottom edge to restrain the lap from opening under wind lift. 13. Air tightness should be considered when assessing the requirement for ventilation above the underlay. A minimum ½ thick counter-batten will allow air movement above the underlay where necessary. Installation over Roof Deck Rafter Pitch Side Laps (horizontal) End Laps (vertical) 10-14 2:12 to 3:12 6 (15 cm) 8 (20 cm) > 15 4:12 and greater 4 (10 cm) 6 (15 cm) * For design consideration without a solid roof deck with draping of roof underlayment that may result in ponding, please contact our technical support team for further information. Please call 1-888-4DELTA4 (433-5824). 3.5 FIELD QUALITY CONTROL A. The owner will engage an independent inspector to observe substrate and installation. The inspector shall provide a written sign-off log on all penetrations before the underlayment is placed against them. The form of the log shall be approved by the Architect before the contract with the inspection service is approved. 3.6 PROTECTING AND CLEANING A. Protect installed vapor permeable underlayment from damage due to ultraviolet light, harmful weather exposures, physical abuse, and other causes. Manufacturer suggests a maximum of three (3) months UV exposure. B. Repair torn vapor permeable underlayment as follows:

Any rips, tears, or holes in the membrane less than 2 in diameter should be patched with DELTA -MULTI-BAND or DELTA FLEXX-BAND, centered over the tear. Any rips, tears, or holes larger than 2 in diameter should be patched with DELTA -VENT S, cut at least 6 larger in diameter than the tear. Center the patch over the tear, and fasten with DELTA - THAN. C. Remove mud and similar marks with a water scrub. If chemicals have been spilled on underlayment, treat as a tear and repair as stated above. END OF SECTION