Thermasheath -3. Insulation for the Building Envelope ROOF WALL SPECIALTY

Similar documents
Thermasheath -3. Insulation for the Building Envelope ROOF WALL SPECIALTY

Thermasheath-XP. Insulation for Exposed Use

TSX Insulation for Exposed Use ROOF WALL SPECIALTY

Thermasheath -3. Insulation for the Building Envelope ROOF WALL SPECIALTY

Thermasheath -3. Insulation for the Building Envelope

Roofing Insulation Products The Trusted Leader in Polyiso Roofing Insulation Solutions

REPORT HOLDER: THE DOW CHEMICAL COMPANY 1501 LARKIN CENTER DRIVE MIDLAND, MICHIGAN EVALUATION SUBJECT:

Gold Bond BRAND Gypsum Sheathing

REPORT HOLDER: R.L. ADAMS PLASTICS, INC CROSSROADS COMMERCE PARKWAY WYOMING, MICHIGAN EVALUATION SUBJECT: POLYCORE BRAND INSULATION

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION SECTION: WATER-RESISTIVE BARRIERS/WEATHER BARRIERS

Trusted ICC ES DIVISION: ATLANTA, CGF PRO, ENERGYS. Look. Conformity! Evaluation. ICC-ES Evaluation

Incorporating Insulating Sheathing into the Design of the Thermal and Moisture Management System of the Building Enclosure

REPORT HOLDER: JOHNS MANVILLE TH STREET DENVER, COLORADO EVALUATION SUBJECT:

ESR-2072 Reissued September 1, 2013 This report is subject to renewal September 1, 2015.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: WATER RESISTIVE BARRIERS/WEATHER BARRIERS SECTION: AIR BARRIERS

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: WATER RESISTIVE BARRIERS/WEATHER BARRIERS SECTION: AIR BARRIERS

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION SECTION: WATER-RESISTIVE BARRIERS/WEATHER BARRIERS

2013 COMMERCIAL PRODUCTS

ESR-1826 Reissued February 1, 2013 This report is subject to renewal February 1, 2015.

BUILDING CODES Presented by CORUM ENGINEERING

for New Construction Applications

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION SECTION: WATER-RESISTIVE BARRIERS/WEATHER BARRIERS

ACFoam-II HCFC Free "Green" Polyiso Specification

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: DEMILEC (USA) LLC

DIVISION: FINISHES SECTION: PORTLAND CEMENT PLASTERING REPORT HOLDER: PROWALL BUILDING PRODUCTS, INC.

SPECIFICATION GUIDELINE

REPORT HOLDER: INSULFOAM, A DIVISION OF CARLISLE CONSTRUCTION MATERIALS, INC TH AVENUE EAST PUYALLUP, WASHINGTON EVALUATION SUBJECT:

ESR-1655 Reissued April 2014 This report is subject to renewal April 1, 2016.

Reflective Insulation Specification & Application Guide for Post Frame and Metal Building Construction

REPORT HOLDER: ATLAS EPS, A DIVISION OF ATLAS ROOFING CORPORATION 8240 BYRON CENTER SOUTHWEST BYRON CENTER, MICHIGAN EVALUATION SUBJECT:

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: ICYNENE, INC.

DIVISION: FINISHES SECTION: PORTLAND CEMENT PLASTERING REPORT HOLDER: SOMAR INDUSTRIES LTD LUCKETT COURT EL PASO, TEXAS 79932

INSTALLATION MANUAL. ZIP System R12 Sheathing. Contents. 07 ZIP System R12 Sheathing Window Installation 08 ZIP System R12 Sheathing Siding Guidelines

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: CERTAINTEED CORPORATION

DIVISION: FINISHES SECTION: PORTLAND CEMENT PLASTERING REPORT HOLDER: SUPERWALL MANUFACTURING, INC.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: DEMILEC (USA) INC.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION SECTION: WATER RESISTIVE BARRIERS/WEATHER BARRIERS

REPORT HOLDER: OMEGA PRODUCTS INTERNATIONAL, INC CALIFORNIA AVENUE CORONA, CALIFORNIA EVALUATION SUBJECT:

Eclipse Energy Guard. Product Information & Installation Manual General Installation Requirements

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: THE SPRAY MARKET, INC.

DIVISION: FINISHES SECTION: ACOUSTIC TREATMENT REPORT HOLDER: ECORE INTERNATIONAL, INC.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: DEMILEC (USA) INC.

ESR-1365 Reissued March 2014 This report is subject to renewal April 1, 2015.

DuPont Tyvek Air Barrier Installation Guidelines. Canadian Version. Version 2

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: LAPOLLA INDUSTRIES, INC.

SECTION REFLECTIVE-FACED, MASONRY CAVITY WALL INSULATION

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION SECTION: AIR BARRIERS REPORT HOLDER:

SPECIFICATION GUIDELINE

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: STRUCTURAL PANELS REPORT HOLDER: ENERCEPT, INC.

COMMERCIAL ROOFING PRODUCTS

DIVISION: FINISHES SECTION: PORTLAND CEMENT PLASTERING REPORT HOLDER: BONSAL AMERICAN, INC.

NOVABRIK MORTARLESS CONCRETE BRICK VENEER SPECIFICATION. MASTERFORMAT SECTION (Mortarless Concrete Brick Veneer)

Legacy report on the 1997 Uniform Building Code, the 2000 International Building Code and the 2000 International Residential Code. *Revised July 2006

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: BASF CORPORATION (RIGID PU SYSTEMS)

DIVISION: FINISHES SECTION: PORTLAND CEMENT PLASTERING REPORT HOLDER: ULTRAKOTE PRODUCTS, LLC

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: SHOP-APPLIED WOOD COATINGS SECTION: SHEATHING REPORT HOLDER:

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: CHEMICAL BROTHERS INTERNATIONAL, LLC

ProGUARD DP The Game-changing Wall System

Firestone Polyiso Boards

DIVISION: FINISHES SECTION: PORTLAND CEMENT PLASTERING REPORT HOLDER: AMERICAN EAGLE MATERIALS, LLC

Sept 30, 2004 Page 1 PRODUCT DESCRIPTION PRODUCT FEATURES

DuPont. Tyvek Sheathing Membrane Installation Guidelines. Version 2. Canadian Version

2006 INTERNATIONAL ENERGY CONSERVATION CODE

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: ICYNENE, INC.

Anchor bolts ASTM F1554, Gr. 36 Wide flange beams ASTM A992, Fy = 50 ksi Misc. structural steel ASTM A36, Fy = 36 ksi

HammerStone Manufactured stone veneers for commercial & residential applications

Trusted ICC ES APA TH STREET. Conformity! subject of the

DIVISION: FINISHES SECTION: PORTLAND CEMENT PLASTERING REPORT HOLDER: OMEGA PRODUCTS INTERNATIONAL, INC.

Trusted DIVISION: 07 SYSTEM. Conformity! ICC-ES Evaluation. not specifically. Copyright 2014

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: RHINO LININGS CORPORATION

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: METAL ROOF PANELS SECTION: METAL WALL PANELS REPORT HOLDER:

PinkWood Ltd. Revised September 29, 2017

REPORT HOLDER: THE DOW CHEMICAL COMPANY 1501 LARKIN CENTER DRIVE MIDLAND, MICHIGAN EVALUATION SUBJECT:

application instructions

General. Moisture. Secondary Water-Resistive Barrier. Storage. Gaps & Sealants. Stud Spacing. Flashing, Windows, Doors & Openings

REPORT HOLDER: PAREX USA, INC EAST LA PALMA AVENUE, SUITE 250 ANAHEIM, CALIFORNIA EVALUATION SUBJECT:

Recommended Design Considerations. and. Guide Specifications For. Commercial Building Insulation

EcoTouch Insulation with PureFiber Technology

Figures 1A-1C Light frame and mass wall systems with continuous insulation for codecompliant. commercial building construction.

(Project Location) (your firm's name)

WATERPROOFING TAMKOWATERPROOFING.COM

ACCESSORY STRUCTURE Building permit information For 1 & 2-family dwellings

INSULATION OWENS CORNING INSULATION PRODUCTS IN THIS SECTION:

TER No Cultured Stone & ProStone Applications Over Continuous Insulation

2003 International Residential Building Code

Technical Bulletin. No. 21 : Insulating Basements and Crawl Spaces (Revised 7/04) hwinsulation CONTRACTORS ASSOCIATION OF AMERICA

TER No Attachment of Exterior Wall Coverings Through Kingspan GreenGuard Extruded Polystyrene (XPS) Sheathing to Wood or Steel Wall Framing

Inspection of New One- and Two- Family Dwellings

Exterior Stucco and Siding Installation

The better way to build TM. Installation Manual FOUNDATION SIPs & FROST WALLS SIPs

Attachment of Exterior Wall Coverings Through Polyiso to Wood or Steel Wall Framing

REPORT HOLDER: HUBER ENGINEERED WOODS, LLC ONE RESOURCE SQUARE DAVID TAYLOR DRIVE, SUITE 300 CHARLOTTE, NORTH CAROLINA 28262

Cladding Attachment Solutions for Exterior Insulated Commercial Walls

SECTION PERMANENT FORMS Insulating Concrete Forms Rev

ESR-2894 Reissued April 2014 This report is subject to renewal April 1, 2016.

SECTION MODIFIED BITUMINOUS MEMBRANE ROOFING Peel & Roof

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: NATURAL POLYMERS, LLC

Administrative Changes

DIVISION: MASONRY SECTION: MANUFACTURED BRICK MASONRY SECTION: MANUFACTURED STONE MASONRY REPORT HOLDER:

Transcription:

Insulation for the Building Envelope ROOF WALL SPECIALTY PRODUCT DESCRIPTION Rmax Thermasheath-3 is an energy-efficient thermal insulation board composed of a closed-cell polyisocyanurate (polyiso) foam core bonded to reinforced aluminum foil facers on each side. Thermasheath-3 utilizes a CFC-, HCFC- and HFC-free blowing agent that has zero Ozone Depletion Potential (ODP) and negligible Global Warming Potential (GWP). This insulation is suitable for use in walls, ceilings and some limited roofing applications in new construction for commercial, residential, agricultural and industrial buildings and in thermal retrofit construction within existing buildings. COMPLIANCES ASTM C289 Type I, Class International Building Code (IBC) Section 2603, Foam Plastic ASHRAE 90. ESR-864, ICC Evaluation Service International Energy Conservation Code (IECC) Miami-Dade County Product Control Approved RR 25322, City of Los Angeles Research Report California Code of Regulations, Title 24 Canadian Construction Materials Centre Evaluation #CCMC 338-L, manufactured to conform to CAN/ULC-S704-03 Type, Class Air Barrier Material per ASTM E278 CONSTRUCTION APPLICATIONS Stud walls; cavity walls; masonry walls; exterior stucco; re-siding; vaulted ceilings; attics and crawl spaces; concrete foundations; limited roofing applications PRODUCT BENEFITS Reduces energy costs Contributes toward LEED credits Offers tax credits, where applicable THERMAL PROPERTIES / PRODUCT DATA R means resistance to heat flow. The higher the R-value, the greater the insulating power. Nominal Thickness Thermal R-Value System R-Value 2 Pcs/Bdl Inches F ft 2 hr/btu F ft 2 hr/btu 0.50 3.2 5.97 96 0.75 5.0 7.77 60.00 6.0 8.77 48.50 9.6 2.37 32 2.00 3. 5.87 24 2.50 6.7 9.47 9 3.00 20.3 23.07 6 3.50 23.9 26.67 3 4.00 27.4 30.7 2 4.50 3.0 33.77 0 Thermal values are determined by using ASTM C58 test method at 75 F mean temperature on material conditioned according to PIMA Technical Bulletin No. 0. 2 Includes the ASHRAE assigned 2.77 R-value of a 3/4 inch dead-air space against a reflective foil in a typical wall assembly. Additional thermal R-values can be found on the insert to this document. Thermasheath-3 is shipped in bundles that are approximately 48 inch high and wrapped in plastic for easy handling. Visit www.rmax.com for a complete list of thicknesses and packaging information. TYPICAL PHYSICAL PROPERTIES Physical properties shown are based on data obtained under controlled conditions and are subject to normal manufacturing tolerances. Property Test Method Results Density, Overall, Nominal ASTM D622 2.0 pcf Compressive Strength ASTM D62 20 psi Flame Spread, Core 2 ASTM E84 75 or Less Smoke Developed, Core 2 ASTM E84 < 450 Water Vapor Transmission ASTM E96 < 0.3 perm Water Absorption ASTM C209 < % Vol. Dimensional Stability ASTM D226, 7 days, 58 F, 98% rh Service Temperatures < 2% Linear Change -40 F to +250 F Also available in 25 psi upon request. Less than inch is only available at 6psi. 2 Flame spread and smoke numbers are shown for comparison purposes only and are not intended to represent the performance of Thermasheath-3 and related components under actual fire conditions. 204-09

APPLICATION / INSTALLATION Stud Wall Construction - Thermasheath-3 applied to the exterior or interior face of studs, to cover all studs, sills, plates and header constructions, provides a layer of continuous insulation (ci) over details not normally covered by insulation products. It may be secured to the framing or structural sheathing with bugle-head screws, galvanized roofing nails or common nails driven through cap washers. Quality-grade construction adhesives may also be used to secure the Thermasheath-3 on interior applications. Exterior facades may include brick/stone veneer, exterior siding and stucco. Thermasheath-3 must be covered on the interior with a minimum /2 inch gypsum wallboard interior finish that is mechanically attached. Masonry Wall Construction - Thermasheath-3 is applied to either the exterior or interior face of concrete or concrete masonry walls to provide a layer of continuous insulation (ci) over the entire surface. It may be secured to the inside face of a concrete or concrete masonry wall, over or under the furring strips, and covered with a minimum /2 inch gypsum wallboard interior finish. Adhesives, screws or nails may be used to hold the Thermasheath-3 in place against the wall temporarily, until the furring strips and gypsum wallboard are installed. The furring strips and gypsum wallboard must be secured with suitable screws or nails. END CAP FURRING 6" O.C. AIR / WATER RESISTIVE BARRIER CMU WALL /2" GYSUM WALL BOARD BRICK TIES AS REQ. BRICK VENEER (Provide weeps as required) THRU-WALL FLASHING (Metal) FURRING AT BASE. Stud walls must be properly braced for lateral loads Stud Wall Construction (Brick Veneer) 02 Cavity Wall Construction Thermasheath-3 (Brick Veneer) Exterior Application - Thermasheath-3 A.00 is an excellent cavity insulation product fitting between the masonry block and finished brick veneer of any residential or commercial project. It may be secured to the dry face of the masonry block wall with a quality grade construction adhesive. Thermasheath-3 can be cut to fit between masonry joint reinforcements placed to tie the brick veneer to the concrete block back-up and installed horizontally in strips to allow the wall ties to extend beyond the face of the insulation leaving the proper air spaces as required. Exterior Stucco Construction - Thermasheath-3 may be used as the insulative sheathing under hard coat stucco finishes. It may be secured to the studs with bugle-head screws, galvanized roofing nails or common-nails driven through cap washers. Cover the Thermasheath-3 with a suitable separation layer such as an organic or inorganic felt. Then, attach conventional metal wire lath and expansion joints with appropriate fasteners as dictated by the local Building Code. Rmax does not recommend the direct attachment of stucco, such as Portland cement or polymer-modified types, directly to the face of the insulation product. Consult stucco manufacturers for details. CMU WALL 6" OR 24" WIDTHS AVAILABLE TO FIT BETWEEN MASONRY WALL TIES OR IMPALE INSULATION OVER WALL TIE PENTILES BRICK VENEER (Provide weeps as required) ORGANIC / INORGANIC FELT METAL LATHE HARD COAT STUCCO METAL FLASHING THRU-WALL FLASHING (Metal) BRICK LEDGE. Stud walls must be properly braced for lateral loads Cavity Wall Construction (Brick Veneer) 04 Thermasheath-3 Exterior Application A.00 Stucco Construction 06 Thermasheath-3 Exterior Application A.00

Re-Siding Construction - Thermasheath-3 may be used in retrofit construction provided the existing siding is sound and solidly attached. It is secured with galvanized nails of sufficient length to penetrate the old sidings, sheathings below and at least one inch into the existing wall studs. Then, cover the Thermasheath-3 with a suitable new siding of aluminum, vinyl, fiber cement, wood or wood fiber based products. EXISTING SHEATHING AND SIDING SEE NOTE # Roofing Construction - Thermasheath-3 is laid over a suitable roof deck such as tongue-and-groove timber, plywood or metal deck and covered with a suitable layer of plywood, wafer board or OSB. Asphalt or wood shingles, concrete or clay tiles or a standing seam metal roof may be installed over the insulated roof deck according to the roofing system instructions. NOTE: It may not be necessary to cover the insulation with a nailable surface when used under a standing seam metal roof assembly, consult manufacturer for details. AIR / WATER RESISTIVE BARRIER ASPHALT SHINGLE ROOFING SYSTEM EXTERIOR SIDING UNDERLAYMENT METAL FLASHING NAILABLE SURFACE FOUNDATION Vaulted Ceiling Construction - Thermasheath-3 may Thermasheath-3 Exterior Application A.00 be applied to the inside face of the roof rafters in vaulted ceiling construction to provide a layer of continuous insulation (ci) and increase the R-value of the roof. Simply nail the Thermasheath-3 to the face of the rafter, cover with a minimum /2 inch gypsum wallboard and finish.. Refer to local building codes for requirements on proper ventilation 2. Stud walls must be properly braced for lateral loads according to the requirements of local Building Codes.. Existing siding must be inspected and re-nailed to provide for solid back-up to attach new sheathing and siding materials. Deteriorated or rotted areas of existing siding must be removed and replaced to restore original thickness. 2. Stud walls must be properly braced for lateral loads Re-Siding Construction ROOF JOIST / RAFTER STUD WALL EXTERIOR WOOD SHEATHING Attics and Crawl Spaces - Thermasheath-3 may be applied to Stud Wall & Vaulted Ceiling Construction 07 the interior face of stud walls or roof Thermasheath-3 rafters Interior within Application attics A.00 and crawl spaces to provide a layer of continuous insulation (ci). Simply nail the Thermasheath-3 to the framing members and cover with an approved ignition barrier such as 3/8 inch gypsum wallboard or /4 inch wood structural panel, particle board or hardboard. Concrete Foundations - Thermasheath-3 may be installed horizontally under foundations and vertically inside of the footings. A separate vapor retarder sheet should be installed directly against the crushed stone base and well tamped backfill or undisturbed earth. Then simply lay in the insulation with tightly butted joints. While not required, taping the joints is acceptable using Rmax R-SEAL 3000, Rmax R-SEAL Construction Tape, or equivalent. 03 STRUCTURAL ROOF DECK. Consult shingle manufacturer for above deck roofing ventilation requirements. LIMITATIONS FASCIA WOOD RAFTER OR TRUSS Thermasheath-3 is not recommended, nor warranted, for use as a commercial roof insulation directly under membrane systems. Consult Rmax Sales for suitable commercial roof insulation products. Thermasheath-3 is not a structural panel. It must not be used as a nailing base for any other building products. Furthermore, stud walls insulated with Thermasheath-3 must be properly braced for lateral loads according to the requirements of local Building Codes. WARNING DO NOT leave Thermasheath-3 exposed. Polyiso foam is an organic material which will burn when exposed to an ignition source of sufficient heat and intensity and may contribute to flames spreading. Installations utilizing Thermasheath-3 must be fully protected on the interior side of the building by a thermal barrier such as a minimum of /2 inch gypsum wallboard. Masonry or concrete that is a minimum of one inch thick, plywood that is a minimum of /2 inch thick and wood that is a minimum of one inch nominal thickness may also be recognized as suitable thermal barriers. Consult your local Building Official for specific governing codes and requirements. The interior and/or exterior of the building should be protected with a suitable vapor retarder and/or a water resistive barrier, if required, based on local Building Codes and climate zone. WARRANTY See Rmax Sales Policy for warranty conditions. Rmax does not assume any responsibility or liability for the performance of any products other than those manufactured by Rmax. NOTE: All Rmax products must be tarped, placed on skids and kept dry before and throughout construction.

Thermasheath-3 Doing one thing well in so many ways... Rmax is a U.S. owned company that only manufactures polyiso insulation. Thermasheath-3 is manufactured in the U.S. and is offered through an extensive distribution network. It is available in standard four foot wide panels, with standard panel lengths of eight or nine feet. Custom lengths are available for special orders. Contact Rmax Sales at your regional Customer Service Center for product availability, pricing information, and your nearest distribution center. Corporate & Technical Rmax Operating, LLC 3524 Welch Road Dallas, Texas 75244-529 Phone: (972) 387-4500 Fax: (972) 387-4673 Email: rmax@rmax.com Web: www.rmax.com Customer Service & Plant Locations Central Region Dallas, Texas (800) 527-0890 Ext. 02 Eastern Region Greer, South Carolina (800) 845-4455 Ext. 56 Western Region Fernley, Nevada (800) 762-9462 Ext. 56 ADDITIONAL THERMAL R-VALUES R means resistance to heat flow. The higher the R-value, the greater the insulating power. According to the ASHRAE Handbook of Fundamentals, the reflective foil facing of Thermasheath-3 contributes additional R-value to the overall assembly when installed against a dead air space. For example, ASHRAE assigns a 2.77 R-value to a 3/4 inch dead-air space against a reflective foil in a typical wall assembly. This value is in addition to the R-value of the polyiso foam - see Sytem R-Value below. Nominal Thickness Thermal R-Value System R-Value Inches F ft 2 hr/btu F ft 2 hr/btu Pcs/Bdl 0.50 3.2 5.97 96 0.75 5.0 7.77 60.00 6.0 8.77 48.25 7.8 0.57 38.50 9.6 2.37 32.55 0.0 2.77 30.75.4 4.7 27 2.00 3. 5.87 24 2.25 4.9 7.67 2 2.30 5.3 8.07 20 2.50 6.7 9.47 9 2.75 8.5 2.27 7 3.00 20.3 23.07 6 3.25 22. 24.87 4 3.50 23.9 26.67 3 3.75 25.7 28.47 2 4.00 27.4 30.7 2 4.25 29.2 3.97 4.50 3.0 33.77 0 Thermal values are determined by using ASTM C58 test method at 75 F mean temperature on material conditioned according to PIMA Technical Bulletin No. 0. Thermasheath-3 is shipped in bundles that are approximately 48 inch high and wrapped in plastic for easy handling. Visit www.rmax.com for a complete list of thicknesses and packaging information. 204-09

Improving Your Design. For warranties, limitations and conditions refer to Rmax Sales Policy and applicable warranties. All documents are located at www.rmax.com. For technical and sales support, email rmax@rmax.com or call (800) 527-0890. Proudly Made and Engineered in the U.S.A. Rmax Sales Offices and Plant Locations Central: 3524 Welch Road Dallas, Texas 75244 East: 649 South Batesville Road Greer, South Carolina 29650 West: 20 Lyon Drive Fernley, Nevada 89408 Phone: 972-387-4500 Phone: 864-297-382 Phone: 775-575-4849 Fax: 972-387-4673 Fax: 864-234-7548 Fax: 775-575-5035 Toll Free: -800-527-0890 Toll Free: -800-845-4455 Toll Free: -800-762-9462 E-mail us at rmax@rmax.com or visit our website www.rmax.com