GENOMICS WORKFLOW SOLUTIONS THAT GO WHERE THE SCIENCE LEADS. Genomics Solutions Portfolio

Similar documents
TIME IT S PRIME. chemagic TM Prime TM instrument Streamlined Walk-away Automation. For all Human Sample Materials. Primary Sample Handling

Illumina TruSeq RNA Access Library Prep Kit Automated on the Biomek FX P Dual-Hybrid Liquid Handler

Single Cell Genomics

Scaling Up NGS Sample Preparation: Automation and Lab Preparation. Alicia Burt Sr. Product Manager

BR-10455A. Automated Multiplexed Gene Expression Profiling Process Solutions. Multiplex Quantitative High-throughput

Agilent Automation Solutions Portfolio FLEXIBLE AUTOMATION MADE EASY

Axygen AxyPrep Magnetic Bead Purification Kits. A Corning Brand

Agilent 2200 TapeStation System ACCELERATE YOUR SAMPLE QC WITH CONFIDENCE

PCR SYSTEMS. a new era in high-productivity qpcr. Applied Biosystems ViiA 7 Real-Time PCR System

Surely Better Target Enrichment from Sample to Sequencer and Analysis

SPRIworks Systems. Push button. Walk away. Fully automated library construction systems with built-in size selection and cleanup BR-15981B

2100 Bioanalyzer. Overview & News. Ralph Beneke Dec 2010

TRUSEQ RNA ON THE SCICLONE LIBRARY PREPARATION NGS LIQUID HANDLER USER S GUIDE ILLUMINA

Implementation of Automated Sample Quality Control in Whole Exome Sequencing

QIAcube HT Your Purification Expert

Agilent Automation Solutions Portfolio. FLEXIBLE AUTOMATION Made Easy

Page Bioanalyzer Assays and Applications

hamilton firefly nimbus 96

Next Generation Sequencing. Target Enrichment

Standard Products Nucleic Acid Sample Submission Guideline

ACCEL-NGS 2S DNA LIBRARY KITS

Lab methods: Exome / Genome. Ewart de Bruijn

WELCOME. Norma J. Nowak, PhD Executive Director, NY State Center of Excellence in Bioinformatics and Life Sciences (CBLS)

LabChip GXII: Antibody Analysis

SCICLONE NGS STRANDED RNA SAMPLE PREPARATION ON THE ILLUMINA TRUSEQ WORKSTATION. User Guide. Workflow: Maestro TruSeq Stranded RNA Rev1

DNA Workflow. Marine Biological Laboratory. Mark Bratz Applications Scientist, Promega Corporation. August 2016

Welcome to the NGS webinar series

CM581A2: NEXT GENERATION SEQUENCING PLATFORMS AND LIBRARY GENERATION

Sole Source Justification (SSJ) in accordance with FAR subparts or 13.5 using Simplified Acquisitions Procedures (SAP) BRAND NAME ONLY

Targeted Sequencing in the NBS Laboratory

resequencing storage SNP ncrna metagenomics private trio de novo exome ncrna RNA DNA bioinformatics RNA-seq comparative genomics

Getting the Most from Your DNA Analysis from Purification to Downstream Analysis. Eric B. Vincent, Ph.D. February 2013

MiSeq. system applications

ExiProgen Protein Synthesis RNA/DNA Prep System Introducing the world's first automated protein synthesis and RNA/DNA purification system!

Performance characteristics of the High Sensitivity DNA kit for the Agilent 2100 Bioanalyzer

IMGM Laboratories GmbH. Sales Manager

Introduction Bioo Scientific

Ion S5 and Ion S5 XL Systems

High-throughput scale. Desktop simplicity.

working with scientists to advance single cell research

Gene Regulation Solutions. Microarrays and Next-Generation Sequencing

Axygen AxyPrep Magnetic Bead Purification Kits. A Corning Brand

Next-Generation Sequencing Services à la carte

Freedom EVO - HSM Workstation

Precise quantification of Ion Torrent libraries on the QuantStudio 3D Digital PCR System

LiquidBiopsy LIQUIDBIOPSY. Automated Rare Template Isolation Platform

All your genetic analyses on a single instrument

MHC Region. MHC expression: Class I: All nucleated cells and platelets Class II: Antigen presenting cells

Accessible answers. Targeted sequencing: accelerating and amplifying answers for oncology research

NEBNext. for Ion Torrent LIBRARY PREPARATION KITS

High Cross-Platform Genotyping Concordance of Axiom High-Density Microarrays and Eureka Low-Density Targeted NGS Assays

Cancer Genetics Solutions

Maxwell RSC System. Next Generation Automated Purification and Quantitation

Evaluating the Agilent 4200 TapeStation System for High Throughput Sequencing Quality Control

NEWSLETTER Kem-En-Tec Nordic

SNP GENOTYPING WITH iplex REAGENTS AND THE MASSARRAY SYSTEM

The first and only fully-integrated microarray instrument for hands-free array processing

Impact of gdna Integrity on the Outcome of DNA Methylation Studies

Comparing the Agilent 2100 Bioanalyzer Performance to Traditional DNA Analysis Techniques

RIPTIDE HIGH THROUGHPUT RAPID LIBRARY PREP (HT-RLP)

Automated size selection of NEBNext Small RNA libraries with the Sage Pippin Prep

Rapid, High-Resolution Microfluidic Separations for Nucleic Acid Analysis

Quantitative analysis of PCR fragments with the Agilent 2100 Bioanalyzer. Application Note. Odilo Mueller. Abstract

MAXimum results. Minimum effort.

Experion Automated Electrophoresis System

Gene Expression on the Fluidigm BioMark HD

Ion S5 and Ion S5 XL Systems

Admera Health RUO Services

DNA purification and analysis

Expression Array System

scgem Workflow Experimental Design Single cell DNA methylation primer design

RT 2 Easy First Strand Handbook

GENE EXPRESSION REAGENTS MARKETS (SAMPLE COPY, NOT FOR RESALE)

High-yield, Scalable Library Preparation with the NEBNext Ultra II FS DNA Library Prep Kit

ExiProgen Protein Synthesis RNA/DNA Prep System

HiSeqTM 2000 Sequencing System

CRISPR/Cas9 Gene Editing

Exploring new frontiers with next-generation sequencing

Thermo Scientific ARM Automation Platform

Applications of Next Generation Sequencing in Metagenomics Studies

Bioinformatics Advice on Experimental Design

RNA SEQUINS LABORATORY PROTOCOL

MAXimum results. Minimum effort.

Molecular Diagnostics OEM and Commercial Supply Services. Your partners for success

LightCycler 480 qpcr Tools. Meeting the Challenge of Your Research

USER GUIDE. Ovation Rapid DR Multiplex System 1 96 PART NO. 0328

DNA Arrays Affymetrix GeneChip System

Next-Generation Sequencing. Technologies

RNA SEQUINS LABORATORY PROTOCOL

Echo-Enhanced SMART-Seq v4 for RNA Sequencing

Introducing the Applied Biosystems TM Precision ID NGS System for Human Identification

SO MUCH SCIENCE SO LITTLE BENCH SPACE. VICTOR Nivo Multimode Plate Reader. For research purposes only. Not for use in diagnostic procedures.

Procedure & Checklist - Preparing Asymmetric SMRTbell Templates

Product selection guide Ion GeneStudio S5 Series

MicroRNA profiling directly from low amounts of plasma or serum using the Multiplex Circulating mirna Assay with Firefly particle technology

Access. Access Laboratory Workstation BROCHURE READY-TO-GO ROBOTIC SYSTEMS FOR ECHO LIQUID HANDLERS. Version 2.1 MAY 2017 LABCYTE INC.

KAPA HiFi Real-Time PCR Library Amplification Kit

MAKE NO MISTAKE, IT S UV THAT EVERYONE CAN USE. LAMBDA 265 / 365 / 465 UV/Vis Solutions

User Requirement Specifications

Contact us for more information and a quotation

Transcription:

GENOMICS WORKFLOW SOLUTIONS THAT GO WHERE THE SCIENCE LEADS Genomics Solutions Portfolio

WORKFLOW SOLUTIONS FROM EXTRACTION TO ANALYSIS

Application-based answers for every step of your workflow Scientists working in genomics research know that providing higher quality DNA for downstream analysis is a critical aspect of the workflow. Our next generation of DNA analysis solutions reduces the complexity and bottlenecks of nucleic acid quantitation and analysis presented by today s sequencing technologies. We're the only partner that can offer technologies upstream and downstream of the genomics workflow, including our automation, microfluidics, and bioinformatics platforms to help scientists analyze nucleic acid efficiently, at the lowest price per sample. Standardized hardware configurations with prevalidated protocols and instrumentation to measure the fundamental characteristics of nucleic acids provide the flexibility and quality control to support novel approaches and chemistries in the NGS process. With our best-in-class nucleic acid extraction, liquid handling, sample preparation, DNA/RNA quantitation, and applications expertise, you have an ally who understands your underlying science and can provide the solutions that address the full breadth of your scientific requirements. All from a singlesource who delivers the application support you need to be up and productive right from the start. Applications Support From DNA to Data Next-generation sequencing (whole genome, exome, targeted amplicon sequencing) Epigenomics Transcriptomics cdna synthesis PCR/qPCR Sample prep from FFPE Genotyping De novo assembly and detection of structural variants Next-Generation Sequencing Workflow Isolate Sample Quantitation of Extracted Samples Generate Library Library Quality Control Sequence Analyze Automated High Yield And Purity Nucleic Acid Extraction Microliter Droplet Spectrophotometry Automated DNA/RNA Capillary Electrophoresis Automated Sample Prep Workstations Automated DNA/RNA Capillary Electrophoresis Methods for: Illumina, KAPA Pacific Biosciences Life Technologies NimbleGen Agilent TIBCO Spotfire Data Visualization GeneSifter Analysis www.perkinelmer.com/genomics 3

PRECISE, RAPID EXTRACTION AND QUANTITATION Getting the highest quality DNA is the critical first step in any genomics sample workflow. You need to be able to extract from a wide range of sample volumes and types and measure for purity, integrity, and concentration. Our solutions for extraction and quantitation ensure that only DNA/ RNA of the highest purity and integrity are used in library generation. ISOLATE SAMPLE JANUS G3 chemagic Workstation Automated high-yield nucleic acid extraction The JANUS G3 chemagic automated workstation combines bestin-class magnetic bead nucleic acid isolation technology with a fully flexible liquid handler to offer reproducible, high-throughput extraction of the highest purity from a variety of blood, plasma and saliva sample types. The system accommodates blood sample volumes from 10 µl to 4 ml with increased throughput and yield when compared to alternative platforms. Independent liquid-handling extraction enables additional flexibility for primary sample transfer, sample normalization, and PCR setup. QC OF EXTRACTED SAMPLES Fast quantitative analysis of DNA/RNA samples LabChip GX Touch Our innovative LabChip GX Touch microfluidics technology delivers unparalleled electrophoresis separation for highsensitivity DNA/RNA analysis, DNA smear analysis, and RNA and gdna integrity analysis all on one platform, in as few as 30 seconds per sample. The system is available in both a 24-sample platform, saving time and reagent expense, and in an HT platform, accommodating up to 384 wells for high-throughput workflows. You choose the right data output for your application: electropherogram, virtual gel, or data table format. And our exclusive genomic quality score (GQS) and RNA quality score (RQS) offer objective guidelines for determining sample integrity. LabChip DS Full-spectrum UV/VIS analysis of small droplets The LabChip DS system analyzes 96 samples in under five minutes, even with volumes as low as 1 µl, allowing for fast, full-spectrum assessment of sample impurities before expensive downstream processing begins. The low volume requirement and broad dynamic range (DNA/RNA: 5 ng to 5,500 ng/µl; protein 0.01 to 200 OD) enable the rapid quantitation of samples. 4

SAMPLE PREP TO ACCELERATE YOUR GENOMICS WORKFLOW Our next-generation sequencing sample preparation solutions eliminate the processing bottlenecks presented by today s sequencing technologies. Open-platform and application expertise enables support for a diverse set of vendor reagent chemistries across our sample preparation portfolio. GENERATE LIBRARY Sample prep with dozens of validated methods The Sciclone G3 NGSx workstation is the high-throughput solution for library prep, sequence capture, and normalization. The system makes it possible to prep samples for up to 480 libraries or 192 exome captures per week, with the flexibility to handle up to 96 samples per run. Plus, the Sciclone G3 NGSx Workstation is a fully enclosed system, so crosscontamination is kept to a minimum. Sciclone G3 NGSx Workstation Benchtop, adaptable liquid handling The JANUS G3 NGS Express workstation uses an intuitive library-prep interface for fragment library preparation, amplicon sequencing, target capture, and sample normalization. It s the perfect complement for benchtop sequencers such as the Ion Torrent PGM and MiSeq systems. JANUS G3 NGS Express Post-PCR NGS liquid handling made simple The Zephyr G3 liquid handling platform is a simple, easy-to-use library prep system specifically designed and preprogrammed to address post-pcr steps in next-generation sequencing sample preparation workflows magnetic bead-based purifications, qpcr setup, sample normalization, and sample pooling (multiplexing) protocols. Zephyr G3 NGS Workstation www.perkinelmer.com/genomics 5

EVERYTHING YOU NEED FROM LIBRARY PREP TO ANALYSIS SEQUENCE Eliminate library preparation bottlenecks Geared toward upfront sample preparation and tracking and downstream data analysis, our solutions offer complete front- and back-end support for commercially available DNA sequencers. We provide easy-to-understand methods to support dozens of premier DNA sequencing applications, such as exome, targeted, microbial, and whole genome. Our highly experienced staff can walk you through high-throughput library preparation, multiplex barcoding, and target capture. With state-of-the-art sequencing using Illumina HiSeq and MiSeq instrumentation, and a tiered approach to bioinformatic support, our application services can enhance your ability to focus on critical discovery. More than 50 open-platform, automation-friendly library prep sequencing methods get you up and running samples in just one week. You can choose from a large selection of available protocols for the chemistry or sequencing platforms you rely on most, including: Agilent Illumina KAPA Biosystems Life Technologies New England Bio Labs NimbleGen Nugen Pacific Biosystems And many more Methods are available for the JANUS G3 NGS Express, Sciclone G3 NGSx and Zephyr G3 workstations. ANALYZE Genomic data visualization and analysis The OmicsOffice Suite leverages TIBCO Spotfire technology's easy-to-use interface to analyze data from large genomic studies, perform comprehensive quality control and use interactive filtering and visualizations to enhance your data analysis. With OmicsOffice Suite, you can seamlessly integrate advanced statistics and annotation management extracting meaningful biological signals and easily identify biomarkers and gene signatures even from your in-house or third party analysis tools. It s an ideal solution for functional genomics, including mrna expression profiling, biomarker discovery, as well as next generation sequencing applications such as RNA- Seq and ChiP-Seq. 6

THE INTEGRATED WAY TO BETTER RESULTS cell::explorer This integrated systems includes JANUS automation, LabChip microfluidics, chemagic nucleic acid extraction, plate:handler barcode labeler and scanner, and a Roche Lightcycler. Explore the possibilities The cell::explorer robotic automation platform leverages our leading liquid-handling extraction and detection expertise to dramatically increase process throughput while improving overall data quality. The integrated cell::explorer gene pro platform provides walkaway automation for all genotyping processes everything from DNA extraction and normalization to PCR plate preparation and realtime PCR all in a compact, space-saving format. And while the cell::explorer platform is an off-the-shelf solution, it s flexible and adaptable to your changing scientific requirements. LabChip for genomic research applications Microfluidics made easy The LabChip GX Touch supports a complete portfolio of quantitative DNA and RNA assays for fragment and NGS smear analysis. Assays vary in size and sensitivity range, depending on the application. For example, the LabChip DNA NGS 3K assay offers the highest sensitivity for low-input samples at very low concentrations (5 to 500 pg/µl) exceeding that of other DNA fluorescent-labeling technologies. StorPlate-96V Application-specific consumable kits Take the hassle out of buying consumables for your Sciclone G3 NGS/NGSx Workstation with customized application-specific consumable kits. These kits provide exactly what you need to run sample preparation workflows for standard reagent platforms. That means less time and money wasted and greater productivity. Sciclone G3 NGS and NGSx workstations run from eight to 96 samples (in multiples of eight). The number of plates, lids, and reservoirs required to complete the run is constant, regardless of the number of samples. www.perkinelmer.com/genomics 7

For research use only. Not intended for diagnostic procedures. For more information, please visit www.perkinelmer.com/genomics PerkinElmer, Inc. 940 Winter Street Waltham, MA 02451 USA P: (800) 762-4000 or (+1) 203-925-4602 www.perkinelmer.com For a complete listing of our global offices, visit www.perkinelmer.com/contactus Copyright 2014-2016, PerkinElmer, Inc. All rights reserved. PerkinElmer is a registered trademark of PerkinElmer, Inc. All other trademarks are the property of their respective owners. 011734A_01 PKI