NEBNext Ultra II Ligation Module

Similar documents
NEBNext Ultra II End Repair/dA-Tailing Module

NEBNext Ultra Ligation Module

NEBNext Quick Ligation Module

NEBNext End Repair Module

NEBNext Ultra II Non-Directional RNA Second Strand Synthesis Module

NEBNext Multiplex Oligos for Illumina (Index Primers Set 2)

NEBNext. Multiplex Oligos for Illumina (Dual Index Primers Set 2)

ProtoScript. First Strand cdna Synthesis Kit DNA AMPLIFICATION & PCR. Instruction Manual. NEB #E6300S/L 30/150 reactions Version 2.

LunaScript RT SuperMix Kit

II First Strand cdna Synthesis Kit

NEBNext rrna Depletion Kit (Human/Mouse/Rat)

AMV First Strand cdna Synthesis Kit

Monarch DNA Gel Extraction Kit

NEBNext Magnesium RNA Fragmentation Module

NEBNext. Multiplex Oligos for Illumina (Dual Index Primers Set 1)

NEBNext Multiplex Oligos for Illumina (Index Primers Set 3)

NEBNext Multiplex Oligos for Illumina (Index Primers Set 4)

Q5 Site-Directed Mutagenesis Kit

POLYMERASES & AMPLIFICATION One Taq RT-PCR Kit Instruction Manual NEB #E5310S be INSPIRED 30 reactions drive DISCOVERY Version 2.0 6/18 stay GENUINE

WarmStart LAMP Kit (DNA & RNA)

NEBNext Fast DNA Fragmentation & Library Prep Set for Ion Torrent

Luna Universal Probe qpcr Master Mix

Q5 High-Fidelity DNA Polymerase

High-yield, Scalable Library Preparation with the NEBNext Ultra II FS DNA Library Prep Kit

HiScribe. T7 Quick High Yield RNA Synthesis Kit RNA ENZYMES & GENE ANALYSIS. Instruction Manual NEB #S1560S. NEB #E2050S 50 reactions Version 2.

NEBNext Microbiome DNA Enrichment Kit

HiScribe. T7 ARCA mrna Kit (with tailing) RNA ENZYMES & GENE ANALYSIS. Instruction Manual. NEB #E2060S 20 reactions Version /16 NEB #S1560S

Isothermal DNA Amplification

High Fidelity (HF) Restriction Enzymes

Cut Smarter with NEB Restriction Enzymes

Automated size selection of NEBNext Small RNA libraries with the Sage Pippin Prep

NEBNext Direct Cancer HotSpot Panel

ab Post-Bisulfite DNA Library Preparation Kit (For Illumina )

Quick and easy 7 minute protocol to select for 300 bp, 200 bp, 150 bp, 100 bp, 50 bp DNA fragments or perform a double size selection

Monarch Total RNA Miniprep Kit

Protoscript II RT-PCR Kit. I n s t r u c t i o n M a n u a l NEW ENGLAND. BioLabs. Version 1.2 3/07. Catalog #E6400S Store at 20 C. Inc.

Gibson Assembly Master Mix

Library Loading Bead Kit (EXP-LLB001) NEBNext FFPE Repair Mix (M6630) Magnetic rack. NEBNext End repair / da-tailing Module (E7546)

StrataPrep PCR Purification Kit

Procedure & Checklist - Preparing SMRTbell Libraries using PacBio Barcoded Universal Primers for Multiplex SMRT Sequencing

EpiNext High-Sensitivity Bisulfite-Seq Kit (Illumina)

Guide-it sgrna In Vitro Transcription and Screening Systems User Manual

Library Loading Bead Kit (EXP-LLB001) Agencourt AMPure XP beads Vortex mixer. Freshly prepared 70% ethanol in nucleasefree

NEBNext. for Ion Torrent LIBRARY PREPARATION KITS

Single Cell 3 Reagent Kits v2 Quick Reference Cards

Library Loading Bead Kit (EXP-LLB001) Agencourt AMPure XP beads Vortex mixer. Freshly prepared 70% ethanol in nucleasefree

Fast and reliable purification of up to 100 µg of transfection-grade plasmid DNA using a spin-column.

Ren Lab ENCODE in situ HiC Protocol for Tissue

Ligation Sequencing Kit 1D (SQK-LSK108) Ice bucket with ice NEBNext End repair / da-tailing Module (E7546)

Single Cell 3 Reagent Kits v2 Quick Reference Cards

Reduced representation bisulfite sequencing Updated 5/19/16, R Kartzinel + K Brzeski Updated 9/12/16, R Kartzinel

DNA Extraction Kit INSTRUCTION MANUAL. Catalog # Revision B. For In Vitro Use Only

BIOO LIFE SCIENCE PRODUCTS

DNAse I qualification and sample treatment

1D^2 Sequencing Kit (SQK-LSK308) Pipettes P2, P10, P20, P100, P200, P1000 Freshly prepared 70% ethanol in nucleasefree

StrataPrep Plasmid Miniprep Kit

TruSeq ChIP Sample Preparation

Hybridization capture of DNA libraries using xgen Lockdown Probes and Reagents

DNA Extraction Kit INSTRUCTION MANUAL. Catalog # Revision A. For In Vitro Use Only

Procedure & Checklist - Preparing Asymmetric SMRTbell Templates

NEBNext Multiplex Small RNA Library Prep Set for Illumina (Set 1)

Genome Reagent Kits v2 Quick Reference Cards

BioResearch. RAFT 3D Cell Culture Kit Protocol

E.Z.N.A. Blood DNA Mini Kit. D preps D preps D preps

Thermo Scientific GeneJET NGS Cleanup Kit

# SimpleChIP ChIP-seq Multiplex Oligos for Illumina (Dual Index Primers) 1 Kit (96 assays) Store at -20 C

Agilent RNA Spike-In Kit

NEBNext Multiplex Small RNA Library Prep Set for Illumina (Set 1)

DRAFT. Apollo 324 System. Protocol. PrepX-32i DNA Library

TruSeq Nano DNA Library Prep Protocol Guide

E.Z.N.A. Size Select-IT Kit. D preps D preps D preps

RealLine Food Kit Turkey Detect

ab DNA-Protein Binding Assay Kit (Colorimetric)

QIAGEN GeneRead QIAact Panel Cleanup Kit Handbook

BigDye Direct Cycle Sequencing Kit

GenBuilder TM Plus Cloning Kit User Manual

SideStep Lysis and Stabilization Buffer

ab DNA Isolation Kit - Plasma/Serum

TruSeq DNA PCR-Free Library Prep Protocol Guide

Archer ALK, RET, ROS1 Fusion Detection v1 Illumina Platform

Introduction. Technical Note

RUO Edition 1, 2015/06 2 OF 36

Size-Select Kit for NGS Library Preparation Product # 53600

Absolutely RNA Microprep Kit

Chromatrap 96 DNA Micro Elution Purification Kit

FosmidMAX DNA Purification Kit

Nextera DNA Sample Prep Kit

KAPA Library Preparation Kit with Real-time PCR Library Amplification for Illumina Platforms

NEBuilder. HiFi DNA Assembly Master Mix/NEBuilder HiFi DNA Assembly Cloning Kit

Multiplex RT for TaqMan Array Human MicroRNA Panel

36 μl 90 μl 360 μl 20 C

Axygen AxyPrep Magnetic Bead Purification Kits. A Corning Brand

Great Savings! FIRST SEMESTER SPECIALS SAVE ON: Africa s Genomics Company. New England BioLabs (NEB) DNA & Protein Ladders

E.Z.N.A. Cycle Pure Kit

E.Z.N.A. Blood DNA Maxi Kit. D preps D preps

ncounter Elements TagSets General Purpose Reagents PACKAGE INSERT Molecules That Count NanoString Technologies, Inc.

Preparing Samples for Sequencing Genomic DNA Using the Genomic DNA Sample Prep Oligo Only Kit

Globin Block Modules for QuantSeq Instruction Manual

TRUSEQ RNA ON THE SCICLONE LIBRARY PREPARATION NGS LIQUID HANDLER USER S GUIDE ILLUMINA

10 RXN 50 RXN 500 RXN

Transcription:

LIBRARY PREPARATION NEBNext Ultra II Ligation Module Instruction Manual NEB #E7595S/L 24/96 reactions Version 2.0 11/17 be INSPIRED drive DISCOVERY stay GENUINE

This product is intended for research purposes only. This product is not intended to be used for therapeutic or diagnostic purposes in humans or animals. ISO 9001 Registered Quality Management ISO 14001 Registered Environmental Management ISO 13485 Registered Medical Devices This product is covered by one or more patents, trademarks and/or copyrights owned or controlled by New England Biolabs, Inc. For more information about commercial rights, please email us at gbd@neb.com. While NEB develops and validates its products for various applications, the use of this product may require the buyer to obtain additional third party intellectual property rights for certain applications. ILLUMINA is a registered trademark of Illumina, Inc. Copyright 2017, New England Biolabs, Inc; all rights reserved.

NEBNext Ultra II Ligation Module Table of Contents: Applications....2 Chapter 1 Protocol for use with NEBNext Ultra II End Repair/dA-Tailing Module...3 Chapter 2 Protocol for use with NEBNext Ultra II FS DNA Module...6 Kit Components...9 Revision History....10 The NEBNext Ultra II Ligation Module Includes: The volumes provided are sufficient for preparation of up to 24 reactions (NEB #E7595S) and 96 reactions (NEB #E7595L). All reagents should be stored at 20 C. Colored bullets represent the color of the cap of the tube containing the reagent. (red) NEBNext Ultra II Ligation Master Mix (red) NEBNext Ligation Enhancer The NEBNext Ultra II Ligation Module is Designed for use with the Following: NEBNext Ultra II End Repair/dA-Tailing Module (NEB #E7546) NEBNext Ultra II FS DNA Module (NEB #E7810) NEBNext Ultra II Q5 Master Mix (NEB #M0544) NEBNext Singleplex or Multiplex Oligos for Illumina (NEB #E7350, #E7335, #E7500, #E7710, #E7730, #E6609, #E7600 or #E7535) 1

Applications: The NEBNext Ultra II Ligation Module is optimized for use with the NEBNext Ultra II End Repair/dA-Tailing Module (NEB #E7546)/ or the NEBNext Ultra II FS DNA Module (NEB #E7810). Each module component must pass rigorous quality control standards, and for each new lot the entire set of reagents is functionally validated together with NEB #E7546 or NEB #E7810 along with NEB #M0544 to construct indexed libraries that are sequenced on an Illumina sequencing platform. For larger volume requirements, customized and bulk packaging is available by purchasing through the OEM/Bulks department at NEB. Please contact OEM@ neb.com for further information. 2

1 Protocol for use with NEBNext Ultra II End Repair/dA-Tailing Module (NEB #E7546) NEBNext Ultra II Ligation Module Instruction Manual 3

CHAPTER 1 Symbols! This caution sign signifies a step in the protocol that has multiple paths leading to the same end point but is dependent on a user variable, like the amount of input DNA. Colored bullets indicate the cap color of the reagent to be added to a reaction. SAFE STOP Stopping points in the protocol. Starting Material: 500 pg 1 µg fragmented DNA that has been end repaired and da-tailed using the NEBNext End Repair/dA-Tailing Module (NEB #E7546).! If DNA input is 100 ng, dilute the NEBNext Adaptor for Illumina in 10 mm Tris-HCl or 10 mm Tris-HCl with 10 mm NaCl as indicated in Table 1.1. 1.1. Add the following components directly to the End Prep Reaction Mixture: Table 1.1: Adaptor Dilution INPUT ADAPTOR DILUTION (VOLUME OF ADAPTOR: TOTAL VOLUME) WORKING ADAPTOR CONCENTRATION 1 µg 101 ng No Dilution 15 µm 100 ng 5 ng 10-Fold (1:10) 1.5 µm less than 5 ng 25-Fold (1:25) 0.6 µm End Prep Reaction Mixture 60 µl (red) NEBNext Ultra II Ligation Master Mix* 30 µl (red) NEBNext Ligation Enhancer 1 µl (red) NEBNext Adaptor for Illumina** 2.5 µl Total volume 93.5 µl * Mix the Ultra II Ligation Master Mix by pipetting up and down several times prior to adding to the reaction. ** The NEBNext adaptor is provided in NEBNext Singleplex (NEB #E7350) or Multiplex (NEB #E7335, #E7500, #E7710, #E7730, #E7600, #E7535 and #E6609) Oligos for Illumina. Note: The Ligation Master Mix and Ligation Enhancer can be mixed ahead of time and is stable for at least 8 hours @ 4 C. We do not recommend premixing the Ligation Master Mix, Ligation Enhancer and adaptor prior to use in the Adaptor Ligation Step. 4

E7595 NEBNEXT ULTRA II LIGATION MODULE 1.2. Set a 100 µl or 200 µl pipette to 80 µl and then pipette the entire volume up and down at least 10 times to mix thoroughly. Perform a quick spin to collect all liquid from the sides of the tube. (Caution: The NEBNext Ultra II Ligation Master Mix is very viscous. Care should be taken to ensure adequate mixing of the ligation reaction, as incomplete mixing will result in reduced ligation efficiency. The presence of a small amount of bubbles will not interfere with performance). 1.3. Incubate at 20 C for 15 minutes in a thermocycler with the heated lid off. 1.4. Add 3 µl of (red) USER Enzyme to the ligation mixture from Step 1.3. Note: Steps 1.4 and 1.5 are only required for use with NEBNext Adaptors. USER enzyme can be found in the NEBNext Singleplex (NEB #E7350) or Multiplex (NEB #E7335, #E7500, #E7710, #E7730, #E7600 and #E6609) Oligos for Illumina. 1.5. Mix well and incubate at 37 C for 15 minutes with the heated lid set to 47 C. 1.6. DNA is now ready for size selection or cleanup. Note: Please see NEB #E7645 manual for recommended size selection/cleanup and PCR amplification protocols. SAFE STOP Samples can be stored overnight at 20 C. 5

2 Protocol for use with NEBNext Ultra II FS DNA Module (NEB #E7810) NEBNext Ultra II Ligation Module Instruction Manual 66

Symbols E7595 NEBNEXT ULTRA II LIGATION MODULE! This caution sign signifies a step in the protocol that has multiple paths leading to the same end point but is dependent on a user variable, like the amount of input DNA. Colored bullets indicate the cap color of the reagent to be added to a reaction. SAFE STOP Stopping points in the protocol. Starting Material: 100 pg 500 ng fragmented, end repaired and da-tailed DNA generated using the NEBNext Ultra II FS DNA Module (NEB #E7810).! If DNA input is < 100 ng, dilute the (red) NEBNext Adaptor for Illumina in 10 mm Tris-HCl, ph 7.5 with 10 mm NaCl as indicated in Table 2.1. Note: The appropriate adaptor dilution for your sample input and type may need to be optimized experimentally. The dilutions provided here are a general starting point. Table 2.1: Adaptor Dilution INPUT ADAPTOR DILUTION (VOLUME OF ADAPTOR: TOTAL VOLUME) WORKING ADAPTOR CONCENTRATION 100 ng 500 ng No Dilution 15 µm 5 ng 99 ng 10-Fold (1:10) 1.5 µm less than 5 ng 25-Fold (1:25) 0.6 µm 2.1. Add the following components directly to the FS Reaction Mixture: COMPONENT VOLUME FS Reaction Mixture 35 µl (red) NEBNext Ultra II Ligation Master Mix* 30 µl (red) NEBNext Ligation Enhancer 1 µl (red) NEBNext Adaptor for Illumina** 2.5 µl Total volume 68.5 µl * Mix the Ultra II Ligation Master Mix by pipetting up and down several times prior to adding to the reaction. ** The NEBNext adaptor is provided in NEBNext Singleplex (NEB #E7350) or Multiplex (NEB #E7335, #E7500, #E7710, #E7730, #E7600, #E7535 and #E6609) Oligos for Illumina. 7

CHAPTER 2 Note: The Ligation Master Mix and Ligation Enhancer can be mixed ahead of time and is stable for at least 8 hours @ 4 C. We do not recommend adding adaptor to a premix in the Adaptor Ligation Step. 2.2. Set a 100 µl or 200 µl pipette to 50 µl and then pipette the entire volume up and down at least 10 times to mix thoroughly. Perform a quick spin to collect all liquid from the sides of the tube. (Caution: The NEBNext Ultra II Ligation Master Mix is very viscous. Care should be taken to ensure adequate mixing of the ligation reaction, as incomplete mixing will result in reduced ligation efficiency. The presence of a small amount of bubbles will not interfere with performance). 2.3. Incubate at 20 C for 15 minutes in a thermocycler with the heated lid off. 2.4. Add 3 µl of (red) USER Enzyme to the ligation mixture from Step 1.2.3. Note: Steps 2.4. and 2.5. are only required for use with NEBNext Adaptors. USER enzyme can be found in the NEBNext Singleplex (NEB #E7350) or Multiplex (NEB #E7335, #E7500, #E7710, #E7730, #E7600 and #E6609) Oligos for Illumina. 2.5. Mix well and incubate at 37 C for 15 minutes with the heated lid set to 47 C. 2.6 DNA is now ready for size selection or cleanup. Note: Please see NEB #E7805 manual for recommended size selection/cleanup and PCR amplification protocols. SAFE STOP Samples can be stored overnight at 20 C. 8

Kit Components NEB #E7595S Table of Components NEB # PRODUCT NAME VOLUME E7648A NEBNext Ultra II Ligation Master Mix 0.72 ml E7374A NEBNext Ligation Enhancer 0.024 ml NEB #E7595L Table of Components NEB # PRODUCT NAME VOLUME E7648AA NEBNext Ultra II Ligation Master Mix 3 x 0.960 ml E7374AA NEBNext Ligation Enhancer 0.096 ml 9

Revision History: Revision # 1.0 N/A Description 1.1 Updated "Designed for Use" to include NEB #E7710 and NEB #E7730 2.0 Updated to include a protocol for use with NEBNext Ultra II FS DNA Module (NEB #E7810). Inserted chapter one and chapter two and applied chapter numbering. 10

DNA CLONING DNA AMPLIFICATION & PCR EPIGENETICS RNA ANALYSIS LIBRARY PREP FOR NEXT GEN SEQUENCING PROTEIN EXPRESSION & ANALYSIS CELLULAR ANALYSIS USA New England Biolabs, Inc. 240 County Road Ipswich, MA 01938-2723 Telephone: (978) 927-5054 Toll Free: (USA Orders) 1-800-632-5227 Toll Free: (USA Tech) 1-800-632-7799 Fax: (978) 921-1350 e-mail: info@neb.com www.neb.com CANADA New England Biolabs, Ltd. Telephone: (905) 665-4632 Toll Free: 1-800-387-1095 Fax: (905) 665-4635 Fax Toll Free: 1-800-563-3789 e-mail: info.ca@neb.com www.neb.ca CHINA New England Biolabs (Beijing), Ltd. Telephone: 010-82378265/82378266 Fax: 010-82378262 e-mail: info@neb-china.com www.neb-china.com FRANCE New England Biolabs France Free Call: 0800-100-632 Free Fax: 0800-100-610 e-mail: info.fr@neb.com www.neb-online.fr GERMANY & AUSTRIA New England Biolabs GmbH Telephone: +49/(0)69/305 23140 Free Call: 0800/246 5227 (Germany) Free Call: 00800/246 52277 (Austria) Fax: +49/(0)69/305 23149 Free Fax: 0800/246 5229 (Germany) e-mail: info.de@neb.com www.neb-online.de JAPAN New England Biolabs Japan, Inc. Telephone: +81 (0)3 5669 6191 Fax: +81 (0)3 5669 6192 e-mail: info.jp@neb.com www.nebj.jp SINGAPORE New England Biolabs Pte. Ltd. Telephone: +65 638 59623 Fax: +65 638 59617 e-mail: sales.sg@neb.com www.neb.sg UNITED KINGDOM New England Biolabs (UK) Ltd. Telephone: (01462) 420616 Call Free: 0800 318486 Fax: (01462) 421057 Fax Free: 0800 435682 e-mail: info.uk@neb.com www.neb.uk.com