RESIDENTIAL RE-ROOFING PERMIT APPLICATION

Similar documents
Re-Roof Permit Checklist

ROOF MITIGATION STRUCTURE EVALUATION FORM. For Single Family Residential Re-Roof Effective October 1, 2007 (Revised February 2, 2018)

Chapter 1 Scope and Administration. Chapter 2 Definitions. Florida Building Code, Residential 5 th Edition (2014) Advanced Code Overview of Changes

ACCESSORY STRUCTURE Building permit information For 1 & 2-family dwellings

Christopher North Builders, INC.

Uniform Mitigation Verification Inspection Form Maintain a copy of this form with insurance policy

COMMERCIAL WINDSTORM MITIGATION INSPECTION REPORT Prepared for: Boca Vista Condominium Association, Inc th Avenue Madeira Beach, FL 33708

POST FRAME BUILDING STANDARDS

GARAGES/ONE-STORY City of Grand Rapids Building Safety Division

Builders, Realtors, Roofers and Yourself

SCREEN PORCHES 101 DEVELOPMENT RESOURCES, INC Permit Requirements

The Loss Mitigation Grant Program Grants for Home Retrofits using Wind Resistive Devices Saturday June 2, 2007

Supplemental Concrete Tilt Up Retrofit Plan Check Correction Sheet (2014 LABC)

PERMIT APPLICATION REQUIREMENTS INTERIOR RENOVATIONS/BUILD OUTS CODES USED: ADOPTED FLORIDA BUILDING CODE & NEC

TOWN OF ROTTERDAM RESIDENTIAL BUILDING PERMIT APPLICATION Ext. 395 Needed to Obtain Permit:

TOWN OF SOUTH KINGSTOWN REQUIREMENTS FOR BUILDING PERMITS RESIDENTIAL SINGLE FAMILY

INSULATION RETROFIT DESIGN ENERGY SOLUTIONS CENTRE YUKON GOVERNMENT

Keri M. Rayborn Silver Rayborn Consultants P.O. Box 1565 Tallahassee, FL P F

Colorado Chapter of the International Conference of Building Officials. Building Guide. The Colorado Chapter of the International

STRUCTURAL ISSUES IN RESIDENTIAL CONSTRUCTION. Presented by: Susan L. Lasecki P.E., S.E.

Administrative Changes

Hurricane- Resistance. designations: WHY FORTIFIED? DESIGNATION PROCESS

BROCHURE # 108 CONSTRUCTION PLAN COMPONENTS

CHAPTER 3 BUILDINGS WITH WOOD FRAMED EXTERIOR WALLS 301 SCOPE

R Code and Commentary for 2012 NC Residential Code final 03/06/13

POST AND FRAME STRUCTURES (Pole Barns)

HATFIELD TOWNSHIP DECK/PATIO PERMIT PROCEDURES

The following preliminary issues may need to be addressed prior to an application for a building permit.

Details for Exterior Brick Masonry Veneer Supported by Metal Plate Connected Wood Trusses

Wall bracing panel requirements

POST AND FRAME STRUCTURES (Pole Barns)

Received by:* Date Received:* Zoning Approval:* Date:* PERMIT#:* *ZONING: *SETBACKS: FRONT ft/ SIDE ft/ REAR ft *FLOOD ZONE:

PERMIT APPLICATION REQUIREMENTS NEW COMMERCIAL BUILDING/CONSTRUCTION CODES USED: CURRENT ADOPTED FLORIDA BUILDING CODE AND NEC

(Project Location) (your firm's name)

Minimum Requirements For One & Two Family Structures FBC 6 th Edition (2017)

WALL CONSTRUCTION CHAPTER 6

Mobile Home Placement Guidelines

CITY OF CITRUS HEIGHTS BUILDING & SAFETY DIVISION

PENNSAFE BUILDING INSPECTION SERVICES LLC Deck and Roof Cross Section Submittal

One and Two Family Additions

Requirement checklist to obtain a building permit for a: RESIDENTIAL POLE BUILDING

PENNSAFE BUILDING INSPECTION SERVICES LLC PERMIT APPLICATION

WILL COUNTY LAND USE DEPARTMENT 2018 CONTRACTOR REGISTRATION

SIDING BUILDING PERMIT APPLICATION

COMMERCIAL WINDSTORM MITIGATION INSPECTION REPORT

INFORMATIONAL PACKAGE ACCESSORY RESIDENTIAL BUILDINGS (INCLUDING DETACHED GARAGES, STORAGE BUILDINGS & WORKSHOPS)

APPLICATION INFORMATION FOR RESIDENTIAL ROOFING AND RESIDENTIAL ROOFING PACKET

Margaret Greene Park Washroom Building 80 Westwood Road, Guelph, Ontario. Structural and Maintenance Remedial Work

Residential Building Inspections

SLATE ROOFING INSTALLATION PROPOSAL [Last updated 10/08/2017]

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: COMPOSITE RUBBER SHAKES REPORT HOLDER: DAVINCI ROOFSCAPES, LLC

City of Santa Monica Building and Safety Division Submittal Requirements Expedited Solar Photovoltaic (10 kw or Less)

Plan Check No. Checked by: An Appointment Is Required for Verification

Addendum No. 1. ITB for Emergency Management/Utilities Administration Building Renovation Addendum Release Date April 06, 2017

Roofing Policy for Commercial Buildings

City of Hughson Building Safety Division 7018 Pine Street Hughson, CA (209)

ROOFING APPLICATION STANDARD (TAS) No. 102(A)-95

SECTION CLAY BARREL TILE ROOFING. A. American Society for Testing and Materials (ASTM):

Exterior Stucco and Siding Installation

Anchor bolts ASTM F1554, Gr. 36 Wide flange beams ASTM A992, Fy = 50 ksi Misc. structural steel ASTM A36, Fy = 36 ksi

Prescriptive Design for Pole Barns Using the Larimer County Prescriptive Handout

SECTION A. ACSE 7 Minimum Loads for Buildings and other Structures.

RESIDENTIAL CONSTRUCTION New Dwellings and Additions

Building Permit Application Instructions INFORMATION REQUIRED FOR ISSUANCE OF A BUILDING PERMIT

FIGURE R502.2 FLOOR CONSTRUCTION

2003 International Residential Building Code

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: FACED PANELS REPORT HOLDER: MEXALIT INDUSTRIAL, S.A. DE C.V.

SECTION PLATE CONNECTED WOOD TRUSSES

HERNANDO COUNTY COMMUNICATION TOWER, ANTENNA & EQUIPMENT CABINET REVIEW REQUIREMENTS

BUILDING PERMIT APPLICATION

Detached Garages and Building Permits. 1 and 2 Family Dwellings

RB104-09/10 R602.7, R (New), Table R (New), Figures R (1)-(2) (New)

MIAMI-DADE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER)

Thermasheath -3. Insulation for the Building Envelope ROOF WALL SPECIALTY

SECTION NON-STRUCTURAL METAL FRAMING

Wood Decks Testing Reveals Best Wood Roof Deck Systems to Resist Wind-Uplift by Fulton Desler, senior engineer, APA The Engineered Wood Association

The Homeowner s Building Application Checklist for Constructing a Residential Addition

ATI Evaluation Service A Division of Architectural Testing Certification Services Code Compliance Research Report

"Nuts & Bolts How fast can wind destroy a home? Simple construction tips to keep yours standing

Table R (1) Allowable Spans and Loads for Wood Structural Panels for Roof and Subfloor. Sheathing and Combination Subfloor Underlayment

CHAPTER 5 FLOORS SECTION R501

RESIDENTIAL DETACHED STORAGE STRUCTURES (GARAGE)

NOTICE TO APPLICANT WARNING TO OWNER AND AFFIDAVIT

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: METAL SHINGLES REPORT HOLDER: TEFUTE BUILDING MATERIALS COMPANY, LLC

City of Republic Community Development Department. Residential Roofs REVISION DATE: JANUARY 2017

130 MPH EXPOSURE B WFCM GUIDE. Guide to Wood Frame Construction in High Wind Areas for One- and Two-Family Dwellings 2015 EDITION

APPLICATION FOR SOLAR PERMIT

BUILDING PERMIT APPLICATION

CITY OF CEDAR FALLS DEPARTMENT OF DEVELOPMENTAL SERVICES INSPECTION SERVICES DIVISION PHONE Residential Accessory Structures

Heel Blocking Requirements and Capacity Analysis. Overview Revised 3/22/2017

STATE UNIVERSITY CONSTRUCTION FUND. UNIVERSITY CON DIRECTIVE 5-1 Issue date: October 2014

SECTION STRUCTURAL RETROFIT ROOF SUB-FRAMING SYSTEM

2012 Wood Frame Construction Manual: Wind Load Distribution on Buildings Load Paths

ESR-2015P* Reissued April 2014 This report is subject to renewal April 1, 2015.

City of Margate, Florida Building Department. Minimum Permit Requirements For Roofing

ROOF ASSEMBLIES CHAPTER 9

SECTION CLAY BARREL TILE ROOFING Removals Flashing and Sheet Metal.

Residential Detached Garage Handout

RE: Notice of Propose Rule Development regarding (OIR-B "Uniform Mitigation Verification Inspection Form"

Transcription:

RESIDENTIAL RE-ROOFING PERMIT APPLICATION Effective date: October 1, 2007. Note: These requirements apply to residential structures built prior to implementation of the FBC on March 1, 2002. I. LEGAL DESCRIPTION: LOT BLOCK SUBDIVISION PARCEL NUMBER: - - - - -. (from tax notice \ receipt) JOB ADDRESS: Value of Residential Structure: $ Re-Roof Contract value: Year Built: Value: show proof of insured value of residential structure or a copy of the ad-valorem tax value. Provide copy of contract IV. PROPOSED USE (Check All That Apply) (Check All That Apply) Type Construction (Check All That Apply) X RESIDENTIAL NEW CONSTRUCTION TYPE V Combustible (All Wood Frame) COMMERCIAL ADDITION TYPE III Exterior Non-Combustible/ Interior Any Material MULTI-FAMILY X ALTERATION TYPE I or II All Non-Combustible (Specify) ACCESSORY Specify: DEMOLITION X OTHER (Sprinkler, Timber Const) Specify: RE-ROOF OWNER NAME & ADDRESS CONTACT INFORMATION Name: CONTRACTOR LICENSE NUMBER: COMP CARD NUMBER: E-MAIL: DAYTIME PHONE NUMBER: Fax: Name: E-MAIL: DAYTIME PHONE NUMBER: Fax: All re-roofs regardless of value shall comply with the following: (Exception where re-roofing over existing roofing) ROOF-OVER Re-nailing: All sheathing and decking shall be re-nailed in accordance with section 201.1 Hurricane Mitigation Manual and a secondary water barrier shall be installed. 201.1 Roof sheathing fastening for site-built single family residential structures. For site-built single family residential structures the fasteners and spacing required in Table 201.1 are deemed to comply with the requirements of Section 507.2.2 of the 2004 Florida Existing Building Code. Board roof decking secured with at least two 8d nails into roof framing members shall be deemed to be sufficiently connected. Board roof decking secured with smaller fasteners than 8d nails or with fewer than two 8d nails per board shall Page 1 of 5

be deemed sufficiently connected if two 8d clipped head, round head, or ring shank nails are in place on each framing member. Supplemental fasteners as required by Table 201.1 shall be 8d ring shank nails with round heads and the following minimum dimensions: 1. 0.113 inch nominal shank diameter 2. Ring diameter of 0.012 over shank diameter 3. 16 to 20 rings per inch 4. 0.280 inch full round head diameter 5. 2-1/4 inch nail length Table 201.1 Supplement Fasteners at Panel Edges and Intermediate Framing Existing fasteners Existing spacing Wind speed 110 mph or less supplemental fastening shall be no greater than Wind speed greater than 110 mph supplemental fastening shall be no greater than Staples or 6d Any 6 o.c. b 6 o.c. b 8d clipped head, round head, or ring shank 6 o.c. or less None necessary None necessary 8d clipped head or round head 8d round head ring shank Greater than 6 o.c. Greater than 6 o.c. 6 o.c. a 6 o.c. b 6 o.c. a 6 o.c. a a. Maximum spacing determined based on existing fasteners and supplemental fasteners. b. Maximum spacing determined based on supplemental fasteners only. Indicate below which method is to be used to satisfy the secondary water barrier requirements: All joints in roof sheathing or decking shall be covered with a minimum 4 in. wide strip of selfadhering polymer modified bitumen tape applied directly to the sheathing or decking. The deck and self adhering polymer modified bitumen tape shall be covered with one of the underlayment systems approved for the particular roof covering to be applied to the roof. The entire roof deck shall be covered with an approved self-adhering polymer modified bitumen cap sheet. No additional underlayment shall be required on top of this cap sheet for new installations. EXCEPTIONS: An asphalt impregnated 30# felt underlayment installed with nails and tin-tabs as required for the HVHZ and covered with either an approved self-adhering polymer modified bitumen cap sheet or an approved cap sheet applied using an approved hot-mop application shall be deemed to meet the requirements for the secondary water barrier. Residential Structure valued at $300,000 or more shall comply with the following: When a roof is replaced on a building that is located in the wind-borne debris region as defined in s. 1609.2 of the Florida Building Code Building (All of Indian River County) and that has an insured value of $300,000 or more or, if the building is uninsured or for Page 2 of 5

which documentation of insured value is not presented, has a just valuation for the structure for purposes of ad valorem taxation of $300,000 or more: (a) Roof to wall connections shall be improved as required by section 201.3. (b) Mandated retrofits of the roof-to-wall connection shall not be required beyond a 15 percent increase in the cost of reroofing. (c) Where complete retrofits of all the roof-to-wall connections as prescribed in Section 201.3 would exceed 15 percent of the cost of the re-roofing project, the priorities outlined in Section 201.3.5 shall be used to limit the scope of work to the 15 percent limit. 201.3 Roof-to-wall connections for site-built single family residential structures. Where required by Section 101.2, the intersection of roof framing with the wall below shall be strengthened by adding metal connectors, clips, straps, and fasteners such that the performance level equals or exceeds the uplift capacities as specified in Table 201.3. As an alternative to an engineered design, the prescriptive retrofit solutions provided in Sections 201.3.1 through 201.3.4 shall be accepted as meeting the mandated roof-to-wall retrofit requirements. 201.3.1 Prescriptive method for gable roofs on a wood frame wall. Sufficient eave sheathing shall be removed to expose a minimum of 6-feet of framing members, measured from the corner, along the exterior wall on each side of each gable end. The anchorage of each of the exposed rafters or truss shall be inspected. Wherever a strap is missing or an existing strap has fewer than four fasteners on each end, approved straps, ties or right angle gusset brackets with a minimum uplift capacity of 500 lbs shall be installed that connect each rafter or truss to the top plate below. Adding fasteners to existing straps shall be allowed in lieu of adding a new strap provided the strap is manufactured to accommodate at least 4 fasteners at each end. Wherever access makes it possible (without damage of the wall or soffit finishes), both top plate members shall be connected to the stud below using a stud to plate connector with a minimum uplift capacity of 500 lbs. 201.3.2 Prescriptive method for gable roofs on a masonry wall. Sufficient eave sheathing shall be removed to expose a minimum of 6-feet of framing members, measured from the corner, along the exterior wall on each side of each gable end. The anchorage of each of the exposed rafters or truss shall be inspected. Wherever a strap is missing or an existing strap has fewer than four fasteners on each end, approved straps, ties or right angle gusset brackets with a minimum uplift capacity of 500 lbs shall be installed that connect each rafter or truss to the top plate below or directly to the masonry wall using approved masonry screws that will provide at least a 2-1/2 embedment into the concrete or masonry. When the straps or right angle gusset brackets are attached to a wood sill plate, the sill plate shall be anchored to the concrete masonry wall below. This anchorage shall be accomplished by installing ¼-inch diameter masonry screws, each with supplementary ¼- inch washer, having sufficient length to develop a 2-1/2 inch embedment into the concrete and masonry. These screws shall be installed within 4-inches of the truss or rafter on both sides of each interior rafter or truss and on the accessible wall side of the gable end truss or rafter. 201.3.3 Prescriptive method for hip roofs on a wood frame wall. Sufficient corner eave sheathing shall be removed from the side of the hip ridge parallel to the roof ridge to provide access to a minimum 6-foot length of the exterior wall. The hip ridge board and any exposed rafters that are not anchored with a strap having at least four fasteners on each end, shall be connected to the top plate below using a strap or a right angle gusset bracket having a minimum uplift capacity of 500 lbs. Adding fasteners to existing straps shall be allowed in lieu of adding a new strap provided the strap is manufactured to accommodate at least 4 fasteners at each end. Wherever access makes it possible (without damage of the wall or soffit finishes), both top plate members shall be connected to the stud below using a stud to plate connector with a minimum uplift capacity of 500 lbs. 201.3.4 Prescriptive method for hip roofs on a masonry wall. Sufficient corner eave sheathing shall be removed from the side of the hip ridge parallel to the roof ridge to provide access to a minimum 6-foot length of the exterior wall. The hip ridge board and any exposed rafters that are not anchored with a strap having at least four fasteners on each end, shall be connected to the concrete masonry wall below using approved straps or right angle gusset brackets with a minimum uplift capacity of 500 lbs. Adding fasteners to existing straps shall be allowed in lieu of adding a new strap provided the strap is manufactured to accommodate at least 4 fasteners at each end. The straps or right angle gusset brackets shall be installed such that they connect each rafter or truss to the top plate below or directly to the masonry wall using approved masonry screws that will provide at least a 2-1/2 embedment into the concrete or masonry. When the straps or right angle gusset brackets are attached to a wood sill plate, the sill plate shall be anchored to the concrete masonry wall below. This Page 3 of 5

anchorage shall be accomplished by installing ¼-inch diameter masonry screws, each with supplementary ¼-inch washer, with sufficient length to develop a 2-1/2 inch embedment into the concrete and masonry. These screws shall be installed within 4-inches of the truss or rafter on both sides of each interior rafter or truss and on the accessible wall side of the gable end truss or rafter. 201.3.5 Priorities for mandated roof-to-wall retrofit expenditures. For houses with both hip and gable roof ends, the priority shall be to retrofit the gable end roof-to-wall connections unless the width of the hip end is more than 1.5 times greater than the width of the gable end. Priority shall be given to connecting the corners of roofs to walls below where the spans of the roofing members are greatest. Table 201.3 - REQUIRED UPLIFT CAPACITIES FOR ROOF-TO-WALL CONNECTIONS (POUNDS PER LINEAR FOOT) Notes: a. The required capacities are pounds per lineal foot of building length. For roof framing spaced at 16 inches on center multiply table values by 1.33. For roof framing spaced at 24 inches on center multiply table values by 2. b. The required capacities include an allowance for 10 pounds of dead load. c. The required capacities do not account for the effects of overhangs. The overhang loads given shall be multiplied by the overhang projection and added to the required capacities in the table. A certified or registered general, building or residential contractor permit application must accompany the re-roof permit application Page 4 of 5

Residential Structure valued over $750,000, with any construction activity of $50,000 or more: Effective: July 1, 2008 Must provide opening protection in accordance with FBC requirements for new construction A certified or registered general, building or residential or an Aluminum Specialties contractor permit application must accompany the re-roof permit application Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit, and that all work will be performed to meet the standards of all laws regulating construction, insurance, and worker s compensation. I understand that sub-contractor affidavits must be obtained for electrical, plumbing, air-conditioning, roofing, insulation, pools, irrigation systems, wells, or any other work that is allowed to be included in this permit. Properties on which earth spills or other debris falls shall be cleaned immediately. All streets, sidewalks, and curbs damaged due to this construction shall be repaired to the satisfaction of the engineering department prior to the issuance of certificate of completion. Owner s Affidavit: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. And/or_ Signature of Owner or Agent Signature of Contractor {To sign as an Agent for the Owner you must have a Florida Form Power of Attorney signed by the Owner and Notarized with two additional witnesses other than the Notary} Date: As to Owner: Date: As to Contractor: State of County of The foregoing instrument was acknowledged before me this day of, 20 by who is personally known or who has produced identification. Type identification produced:. Official Signature of Notary Public Notary s Name, Typed, Printed or Stamped State of County of The foregoing instrument was acknowledged before me this day of, 20 by who is personally known or who has produced identification. Type identification produced:. Official Signature of Notary Public Notary s Name, Typed, Printed or Stamped Notary Seal: Notary Seal: Building Permit Fee: = $ Page 5 of 5