INFOTEXT. OKALUX Light Diffusing Insulating Glass. Physical properties

Similar documents
OKASOLAR. Glazing with Integral Daylight Control

Product information Vertical window element VFE

OKATECH. Insulating Glass with Functional Metal Insert

Product information Additional window element GIU

Visionary Façade Concepts with Solar-Control Glazing. x ipasol x Stopray x Sunergy x Stopsol

OPTIWIN MOTURA. Technical Description. Synopsis:

Solar-Control Glazing. Visionary Façade Concepts

ENERGY EFFICIENT GLASS LESS ENERGY, MORE SAVINGS, BETTER FUTURE

Product information Centre-pivot white-painted roof window GGL

Product information Roof terrace GEL + VEA/VEB/VEC

Product information Roof balcony CABRIO GDL

Multi-Cavity Insulating Glass Units

real DAYLIGHTING solutions SOLERA

European Timber Windows & Doors

Acid-etched Glass for Exterior Applications A Unique Way to Move Light!

SageGlass. SageGlass Product Guide. Dynamic glass for a changing world

NEED FOR A CORRECT GLASS DESCRIPTIVE CODE: ENERGY-CODING

SOLAR PHOTOVOLTAIC ASI GLASS E. ASI Glass. Integrated Architecture Powered by the Sun

INTELLIGENT GLASS SYSTEMS

More space, more light, a better quality of life: The high insulated folding sliding doors from Schweizer.

OKASOLAR W Insulating Glass with Integral Sun Control Louvres. type and thickness of glass according to static requirements

Observation of Liquid-filled Window without Presence of Liquid in Test Chamber

PRIVA-LITE PRIVACY DESIGN COMFORT INNOVATIVE SOLUTION FOR YOUR BUILDING BUILDING GLASS UK & IRELAND SAINT-GOBAIN BUILDING GLASS UK & IRELAND / 1

ClimaGuard Neutral 70

SCREEN NATURE ULTIMETAL

Domes Pyramids Opening Rooflights Flatglass Rooflights

Report for the U-value of a Door System in Accordance with BS EN ISO :2006. Product description:

Columbia Skylights may qualify your project for LEED points in the following categories: Columbia Skylights - Potential Contribution to LEED projects

SGG PLANITHERM TOTAL New generation advanced performance low-e glass

PRACTICAL GUIDE MULTIVER RESIDENTIAL GLASS. Quebec. Version 2.0

This panel with its unique optic has a wide variety of outdoor application possibilities due to special top sheets.


OKAWOOD. Glass with Functional Timber Insert

EDITION AUGUST 2016 PRIVA-LITE COMFORT INTIMACY DESIGN INNOVATIVE SOLUTION FOR MODERN ARCHITECTURE SAINT-GOBAIN BUILDING GLASS EUROPE / 1

Product information VELUX INTEGRA flat roof window CVP with curved glass cover ISD

SILVERSTAR-Solar control glass

Product information Fixed flat roof window CFP

Between you and nature...

PART 1 - GENERAL 1.01 SUMMARY 1.02 REFERENCES. Section Glazing. JE Berkowitz, L.P

slimlite Double Glazed Units BS EN 1279 Certificate Double Glazed Units

Solar control. Applications. solutions meet functional and styling demands (second part) Automotive glass

movable walls Space Optimal Solutions

SECTION SPECIAL FUNCTION GLAZING

A Case Study on the Daylighting and Thermal Effects of Fixed and Motorized Light Louvers

STEADY STATE AND DYNAMIC THERMOPHYSICAL PARAMETERS OF TRANSPARENT BUILDING COMPONENTS

Product information VELUX INTEGRA centre-pivot roof window GGL

Product information Flat roof smoke ventilation window CSP

Selecting Energy Efficient New Windows in Tennessee

World s best-performing glass curtain wall

Lexan*Thermoclear* Solar Control IR Sheet

Selecting Energy Efficient New Windows in Nevada

SECTION DYNAMIC GLAZING PART 1 - GENERAL 1.1 SUMMARY

WEEDOO - SA CONSTRUCTION TECHNOLOGY

ASSESSMENT T-STRIPE. Rautenweg Wien

Selecting Energy Efficient New Windows in Illinois

Insulated double and triple glass units, custom-built to specification and manufactured to the highest standards. Insulated glass units

Selecting Energy Efficient Replacement Windows in Arizona

POLYGAL Multiwall Sheets. commitment

The more intelligent way to insulate: Thermix TX.N plus Warm edge spacers for insulating glass

Solar Shading System Based on Daylight Directing Glass Lamellas

SECTION Structured Polycarbonate Panel Assemblies. Series 3500 BPC System with 40mm Tongue and Groove

Clear float glass. Pilkington OptiView. Anti-reflective Glass

SCREEN DESIGN NATURA COLLECTION INTELLIGENT FABRICS FOR SOLAR PROTECTION. Width: 250 cm

Introduction to basics of energy efficient building design

An enhancement of the daylighting from side-window using two-section venetian blind

DAYLIGHT PANELS A WIND AND WATERPROOF SYNTHETIC GLAZING SYSTEM

Architect: YATLAOL 55 (Y+Y, Atlanta, Atelier 55, Eole)

PART 1 - GENERAL 1.01 SUMMARY 1.02 REFERENCES. Section Glazing. JE Berkowitz, L.P

Available online at ScienceDirect. Procedia Engineering 146 (2016 ) 60 68

CI/Sf/B. (31) Ro5 (M5) April The width of single glazing. The warmth of double glazing. Pilkington Spacia Revolutionary vacuum glazing.

THE LABAN DANCE CENTRE DEPTFORD, LONDON, UK

SCHOTT UK Ltd Sales Office Drummond Road Stafford ST16 3EL Phone: Fax:

HOW CURRENT TRENDS IN THE DESIGN OF FACADES INFLUENCE THE FUNCTIONAL QUALITY OF INTERIOR SPACES

Architect: Joël Claisse, Photographer: Geraldine Claisse

Extended pilot study of an energy efficient glazed office building during pre-design and design. Åke Blomsterberg (WSP och LTH)

LUXAR. Anti-reflective glass

ENERGY STAR Qualifying Criteria for Residential Windows, Doors, and Skylights Sold in Canada Version 3.0 October 1, 2010

Guide Specifications Section

Lexan* Thermopanel Sheet LTP30B4RS36. Property Profile Value Test Method. Lexan*

STRUCTURAL GLASS FACADE ALL GLASS FINS & BEAMS

HNG Float Glass. Corporate Head Office Mumbai Plant Location Halol (45 Kms from Vadodara) Regd Office Kolkata

Homes. for living WINDOWS DOORS CONSERVATORIES TO HELP YOU REALISE YOUR DREAM

Thermal Bridging and Whole Building Energy Performance

OPACI-COAT Water-base Silicone Glass Coating

3 Specification 3.1 Dimensions Lites of overall dimensions ( x ) inches / mm.

Evidence of Performance Calculation of thermal transmittance

Radiation Shielding Glass RD 30 RD 50

Triple glazed windows Enhanced energy efficiency

Insulated Glass Units

Thermal Characteristics and Energy Performance of Double Skin. Façade System in the Hot Summer and Cold Winter Zone

Vengen 28. There s a much bigger picture to be found at Ruskin Air Management. Double Glazed Thermal Break Louvre Window. naco.

A. Manufacturer: A firm that produces primary glass or fabricated glass as defined in referenced glazing publications.

Laminating Division Technical Committee. Superwide Laminates and ASTM C1172

SCHOTT Architecture + Design. Building Integrated Photo Voltaic Wall Element Glass

A STUDY OF DAYLIGHTING TECHNIQUES AND THEIR ENERGY IMPLICATIONS USING A DESIGNER FRIENDLY SIMULATION SOFTWARE

5.0 Daylighting Analysis (Breathe Study)

LAMILUX PASSIVE HOUSE DAYLIGHT SYSTEMS MAXIMUM EFFICIENCY FOR ACTIVE ENERGY MANAGEMENT

The Technical Merit of Double Facades for Office Buildings in Cool Humid Climates

Coated Glass. Stopsol Sunergy Planibel G

Coupled windows in the current guise

Transcription:

OKALUX Light Diffusing Insulating Glass The challenge for OKALUX Light Diffusing Insulating Glass: to make daylight useful. With the use of a translucent light diffusing capillary insert (OKAPANE) both sides covered with additional glass fibre tissues in the cavity, OKALUX achieves optimum, uniform light transmittance into the room, irrespective of irradiation conditions light transmission and total solar energy transmittance as required very good colour rendering index good heat insulation UV protection as required sound insulation as required vision protection and glare protection attractive appearance in daylight and in artificial light visibility for birds Physical properties Thermal insulation The OKAPANE insert reduce the heat transfer in the cavity between panes in terms of convection and heat radiation. The thicker the OKAPANE, therefore, the better the Ug value. For OKAPANE thicknesses of 24 mm and over, we recommend the use of our OKALUX EVO product, which enables Ug values of 1.3 W/(m²K) to be achieved. With the triple pane make (OKALUX K product variant) it is possible to achieve Ug values of 0.8 W/(m 2 K). The Ug value of insulating glass in accordance with DIN EN 673 or DIN EN 674 always relates to vertical installation. If the insulating glass is at an angle, e.g. as in roof glazing, the Ug value increases, because the rising convection level in the cavity. Duplex insulating glass with a standard value of Ug = 1.1 W/(m²K) has an actual value of approx. 1.7 W/(m²K) if used for horizontal roof glazing. OKAPANE in the cavity between panes prevents convection, which means that the Ug value of OKALUX is constant whatever the installation position. For roof glazing, OKALUX glass with a 24 mm capillary slab achieves the same Ug value as insulating glass with a Ug of 1.1 W/(m²K). IT_E_OKALUX_170828 1 (5)

2,2 Ug [W/(m²/K) following DIN EN 673] 2,0 1,8 1,6 1,4 1,2 1,0 0,8 0,6 0,4 0,2 0,0 90 75 60 45 30 Air 16 mm Argon 16 mm Krypton 10 mm OKALUX 24 mm OKALUX K OKALUX+ OKALUX EVO 40 mm 15 0 inclination (90 = vertical) Sound insulation OKAPANE decouple the panes of the insulating glazing and provide improved sound insulation. Spectral properties The special light diffusing properties of the OKAPANE insert provide an optimized, uniform distribution of light in the room, regardless of irradiation conditions. The special geometry of the OKAPANE capillary material results in improved heat insulation with an increased thickness, but without any notable reduction in light transmission. The g value and the light transmission are dependent on the make-up of the light diffusing inserts. Other g values and light transmission values can be provided on request with the use of special make-ups. UV protection Very low UV transmission possible on request. Technical values of standard types The following details apply to glass make-ups with a 6 mm outer pane and a 8 mm laminated safety glass as inner glass pane (0.76 PVB foil). IT_E_OKALUX_170828 2 (5)

Table 1. Spectral properties OKALUX Tv Type direct Tv diffuse TSET direct SC 45/47 45 34 47 55 38/40 38 29 40 47 32/36 32 25 36 42 28/32 28 22 32 37 25/28 25 19 28 33 22/26 22 17 26 30 Table 2. U g value and Rw value Capillary slab [mm] 8 12 16 20 24 32 40 Ug [W/(m²K)] 2.7 2.5 2.2 1.9 1.7 1.5 1.3 Ug [Btu/(hr ft² F)] 0.48 0.44 0.39 0.34 0.30 0.26 0.23 Rw [db] 38 40 41 42 43 44 45 Legend and related values: unit standard technical term Ug W/(m 2 K) DIN EN 673 DIN EN 674 Thermal transmittance TSET DIN EN 410 Total solar energy transmittance or solar heat gain coefficient Tv DIN EN 410 Light transmission (direct/hemispheric resp. diffuse/ hemispheric) Rw db DIN EN 20140 Sound reduction coefficient FC DIN 4108 Reduction factor of a solar control system, FC=TSET/TSETreference SC GANA Manual Shading coefficient, SC=TSET/0.86 The above data are approximate data. They are based on measurements of approved test institutes and calculations derived from these measurements. Values determined on a project-specific basis may vary from the above values. Direct transmission relates to direct incidence of light, generally vertical (model situation for direct sunlight). Diffuse transmission applies to homogeneous, diffuse incidence of light from the outer hemisphere (model situation for an overcast sky). All values were measured hemispherically. A low-e coating or a combined sun-control and low-e coating at position 2 changes the color appearance when viewed from outside. The specified values may change as a result of technical developments. No guarantee is therefore given for their correctness. Ph.: +1 914 202-0274 Fax:+1 914 607-7977 www.okaluxna.com info@okaluxna.com IT_E_OKALUX_170828 3 (5)

Make-up What makes OKALUX light diffusing insulating glass so special is the OKAPANE inserted in the cavity between the panes. The glass type and thickness vary according to static requirements and design requirements. Standard make-up: Outer pane additional glass fibre tissues OKAPANE 8-24 mm (Special make-up > 24 mm capillary slab size on application) additional glass fibre tissues Inner pane Variations in the density of the capillary slab and the diameters of the OKAPANE may be visible, as can joints which are necessary for production reasons. These "variations" in appearance give the product a lively appearance.under certain light conditions it may also be possible that fine lines and wrinkling of the tissues, also the result of the production process, can be seen within the OKAPANE. The physical characteristics of OKALUX are not adversely affected by the above. Dimensions larger glass dimension up to 4500 mm no restrictions smaller glass dimension smaller than 1500 mm no restrictions 1500 mm to 2000 mm light transmission not more than 32 Larger than 2000 mm subdivision by joint with aluminium profile For tolerance reasons and due to differing temperature expansion, the insert may be exhibit an expansion gap of up to 2.0 mm on each side. This can lead to a visible gap between the insert and the spacer bar. For this reason, the edge cover must amount to at least the required overall seal width plus 5 mm or be covered using an edge screen print (spacer bar + secondary bar). In the case of a polysulphide as secondary seal, it may be necessary to use a exceed cover in order to provide sufficient UV protection. In the case of a frameless glazing system, it is generally recommended that the edge areas are covered using a screen print. Depending on loading, the required sealant width can be considerably greater than that of conventional insulating glazing. Planning instructions Builder-owners and architects must be able to technically assess the effect of glazing in daylight terms. Okalux offers such calculations as a voluntary extra service without obligation. The daylight-relevant properties of the room to be examined must be known; in particular, these are: room geometry, window dimensions approximate degree of reflection of the surfaces forming the room boundaries The so-called daylight coefficient (D) in accordance with DIN 5034, Part 3, is relevant for the evaluation of the ambient daylight. This gives the ratio between the horizontal luminous intensity indoors and out of doors, under a completely overcast sky. This value can be calculated for different glazing variants using the existing simulation tools. The customer can thus assess the light-directing effects of special IT_E_OKALUX_170828 4 (5)

products, in comparison with normal glazing as well. In addition to the assessment in accordance with DIN, virtual images can visualise the light distribution in the rooms. Installation instructions OKALUX light diffusing insulating glass is used for glazing like normal insulating glass. For instructions and recommendations for the installation of our insulating glazing, please refer to our information and instructions for customers contained in "Delivery of OKALUX Glass Products" and "General Information on Glazing". Other printed matter If you do not have the following printer matter, please request it directly from OKALUX or download it from the Internet at www.okalux.com: General terms and conditions of business Product-specific information texts As well as these, there are the following customer notes: Customer notes on offers Customer notes on delivery Customer notes alarm glass Customer notes screen printing Customer notes Structural Glazing / Edge deletion Customer notes on heat-soak test Customer notes on glazing Customer notes SIGNAPUR Customer notes OKAWOOD tolerances Cleaning instructions for OKALUX gen. Cleaning instructions OKACOLOR Guideline for visual quality IT_E_OKALUX_170828 5 (5)