TONAL NOISE MITIGATION ON WIND TURBINES

Similar documents
MEASUREMENT AND LEVEL OF INFRASOUND FROM WIND FARMS AND OTHER SOURCES

DETAILED ANALYSIS OF MEASUREMENT RESULTS OF FLANKING TRANSMISSION ACROSS A JUNCTION COM- POSED OF DOUBLE WALLS CARRIED OUT ON A HALF SCALED TEST BENCH

INFRASOUND AND BLADE PASS FREQUENCY LEVELS IN AREAS ADJACENT TO WIND FARMS

Proposed Revisions to. Wind Energy Development Guidelines Targeted Review in relation to Noise, Proximity and Shadow Flicker December 11 th 2013

VIBRATION CONTROL FOR A 25 MW STEAM-TURBINE GENERATOR INSTALLATION NEAR ACADEMIC TEACHING AND RESEARCH LABORATORIES

DYNAMIC TEST OF MULTIPLE TUNED MASS DAMPERS FOR VIBRATION CONTROL OF HIGH-RISE BUILDINGS

Wind Turbine Noise, Infrasound and Noise Perception

Kamperman & James Nine-page summary edition Page 1 of 9

CHAPTER 3 IMPROVEMENT OF DYNAMIC CHARACTERISTICS OF CUTTING TOOL SYSTEM USING VISCOELASTIC DAMPER

Aerodynamic Noise from Wind Turbines

Rumster Wind Energy Project

WIND TURBINES. Vibration Control of: Wind Turbines APPLICATIONS POWER GENERATION - WIND TURBINES

Dynamic Design of the Foundation of Reciprocating Machines for Offshore Installations in Persian Gulf

Experimental Validation of Building Vibration Propagation Using a Four Story Laboratory Model

BARON WINDS SOUND MONITORING AND COMPLIANCE PROTOCOL

Non-Traditional Noise and Vibration Mitigation Strategies. Christopher Layman, Ph.D. Shannon McKenna Judy Rochat, Ph.D. ATS Consulting Pasadena, CA

The Clem7 Motorway Tunnel: Mechanical and Electrical Plant Acoustic Design and Performance

Fatigue Analysis of a Wind Turbine Power Train

Simplified Finite Element Modelling of Multi-storey Buildings: The Use of Equivalent Cubes

Dynamic Time History Analysis of Plane Frame with Tuned Mass Considering Soil-Structure Interaction

GE Power & Water. Improved Aeroacoustics and Noise Management Options. Saskia Honhoff, Dr. Benoît Petitjean, Dr. Roger Drobietz, Dr. Kevin W.

Synergy Wind Pty Ltd PO Box 327 Balaclava VIC 3183

DESIGN OF PASSIVE COMPOSITE ISOLATION SYSTEM FOR MACHINE FOUNDAION

VIBRATION MEASUREMENT PLAN FOR FEED-WATER PIPING SYSTEM FOR THE APR1400 COMPREHENSIVE VIBRATION ASSESSMENT PROGRAM

Spatial variability effects of the seismic action in Cable-Stayed Bridges and modelling techniques

Effectiveness of Tuned Liquid Column Dampers on Vibration Behavior of One-story Steel Structure under Harmonic Force and an Earthquake Record

Vibration Generated Due To Pile Driving In Water And Soil

DESIGN AND ANALYSIS OF WIND TURBINE NACELLE TRANSPORT FRAME FOR ROAD TRANSPORT

DYNAMIC CHARACTERISTICS ASSESSMENT OF STEEL BEAM-COLUMN CONNECTIONS WITH FLOOR SLAB

Comparison of compliance results obtained from the various wind farm standards used in Australia

Evaluating Ontario Regulations for Siting Turbines. in Context of. Findings from the Health Canada Study

inter.noise 2000 The 29th International Congress and Exhibition on Noise Control Engineering August 2000, Nice, FRANCE

PERFORMANCE OF TUNED MASS DAMPERS FOR RESPONSE REDUCTION OF STRUCTURES UNDER NEAR-FIELD AND FAR-FIELD SEISMIC EXCITATIONS

Noise and vibration control in aerospace composite structures

MODELING THE STRUCTURAL DYNAMICS OF CHOSEN COMPONENTS OF THE HORIZONTAL AXIS WIND TURBINE

WIND FARMS TECHNICAL PAPER. Environmental Noise. Prepared for. CLEAN ENERGY COUNCIL Suite 201, 18 Kavanagh Street SOUTHBANK 3006

INTERNATIONAL STANDARD

Wind Turbine Generator System Acoustic Noise Test Report. Bergey Excel Wind Turbine

OPTIMUM INSTALLATION OF VISCOUS LIQUID DAMPERS IN HIGH-RISE BUILDINGS

STRUCTURE-BORNE SOUND PROPAGATION ACROSS A DOUBLE LEAF TIMBER-FRAME WALL

Transactions, SMiRT-22 San Francisco, California, USA - August 18-23, 2013 Division V

Earthquake Analysis of Tall Building with Tuned Mass Damper.

TUNNEL BORING MACHINE VIBRATION IMPACT PREDICTION METHOD BASED ON SURFACE VIBRATION MEASUREMENTS AND TUNNEL TO SURFACE TRANSFER FUNCTION CALCULATION

Source Noise Control to Mitigate Airborne Noise at High Rise Developments - Epping to Chatswood Rail Link

A Guide to Design Load Validation

Vibration insulation of footbridges so as to reduce human discomfort

Finite Element Stress Analysis and Vibration Analysis for a Geothermal Separator

CASE STUDY OF THE SOUND REDUCTION OF VARIOUS RESIDENTIAL GLAZING TREATMENTS

Modelling the influence of building types on the building response to railway vibration

NOISE AND VIBRATIONS HIGH SPEED, LIGHT CRAFT AND NAVAL SURFACE CRAFT RULES FOR CLASSIFICATION OF DET NORSKE VERITAS

Fatigue Analysis of a Welded Structure in a Random Vibration Environment

5-MW Downwind Wind Turbine Demonstration and Work Toward Smart Operation Control

Statutory Order on noise from wind turbines

LOW-CYCLE FATIGUE FAILURE MECHANISM OF WIND TURBINE FOUNDATION DUE TO VIBRATION OF UPPER STRUCTURE

NUMERICAL MODELLING IN ACOUSTICS, DYNAMICS AND VIBROACOUSTICS M G Smith ISVR Consulting, University of Southampton, University Road, SO17 1BJ, UK

ACOUSTICAL TREATMENT OF EMERGENCY POWER GENERATOR. Dr. M.Abd El Gawad Saif

SEISMIC ANALYSIS AND DYNAMIC TESTING OF A SPILLWAY RADIAL GATE

FINITE ELEMENT ANALYSIS OF A SHAFT SUBJECTED TO A LOAD

Gibbet Hill Wind Farm Noise Monitoring Report

The DTU 10MW Reference Wind Turbine

Use of ISO measurement uncertainty guidelines to determine uncertainties in noise & vibration predictions and design risks

Seismic Considerations of Circuit Breakers

Environmental Noise Compliance Assessment Bass Point Quarry

WHY IS WIND TURBINE NOISE POORLY MASKED BY ROAD TRAFFIC NOISE? 2 GGD Amsterdam.

Variations of sound from wind turbines during different weather conditions

A NEW VIBRATION DAMPING FACILITY FOR STEEL CHIMNEYS

Noise reduction through mechanical damping in composite sandwich structures

OPTIMUM DAMPING IN ISOLATION SYSTEM

Reduction of Natural Frequency due to Flexural Cracks or Shear Cracks in Reinforced Concrete Members

Rainfall and impact noise measurements on metal roof tiles

Short Communication Infrasound Noise of Natural Sources in the Environment and Infrasound Noise of Wind Turbines

Proceedings of Meetings on Acoustics

TURBO GENERATOR MACHINE FOUNDATIONS SUBJECTED TO EARTHQUAKE LOADINGS

Linear and Nonlinear Seismic Analysis of a Tall Air Traffic Control (ATC) Tower

The Numerical Prediction and Features Analysis of Cylindrical Shell Acoustic Radiation Noise

This point intends to acquaint the reader with some of the basic concepts of the earthquake engineer:

ALPHA-OMEGA 1 MW WIND GENERATOR ALPHA OMEGA ECOLOGICAL SOLUTIONS. Direct Phones: &

Sound, Noise and Vibration

Wind farm aural and visual impact in the Netherlands

INFLUENCE OF BNWF SOIL MODELLING ON DYNAMIC BEHAVIOUR OF PILE FOUNDATION FOR RC FRAME WITH STRUCTURAL WALL

Analysis of Seismic Waves Generated by Blasting Operations and their Response on Buildings

Noise Impact Assessment

VIBSOLFRET: ground vibrations induced by freight traffic, from the track to the building

Design of large scale wind turbine towers in seismic areas

Pumping System Vibration

EARTHQUAKE RECORDS OBSERVED IN TALL BUILDINGS WITH TUNED PENDULUM MASS DAMPER

GARAGE STRUCTURE VIBRATION TRANSMISSION TO HUMAN OCCUPIED SPACES

A REPORT ON THE EFFICIENCY OF A WHALEPOWER CORP. 5 METER PROTOTYPE WIND TURBINE BLADE

VIBRATION CONTROL SYSTEMS FOR TRACKBEDS AND BUILDINGS USING COIL STEEL SPRINGS

February 7, 2017 Mr. Daniel Wolf Executive Secretary Minnesota Public Utilities Commission th Place East, Suite 350 St. Paul, MN

Ultrasonic testing of adhesive bonds of thick composites with applications to wind turbine blades

Offshore Requirements for Turbine Exhaust System Analysis and Design

Analytical Model of Vibration Transmission Through the 5M10000 Mount

SITE-SPECIFIC LOADS COST AND BENEFITS OF MONITORING. Ursula Smolka SUPERGEN Wind Hub, Cranfield, 23 November 2016

VIBRATIONS CONSULTING. OVERVIEW OF SERVICES Measurement+Evaluation Seismic+Dynamic Analysis Vibration Control Tuned Mass Damper Design

FE MODELING OF CFRP STRENGTHENED CONCRETE BEAM EXPOSED TO CYCLIC TEMPERATURE, HUMIDITY AND SUSTAINED LOADING

SOIL-STRUCTURE INTERACTION EFFECTS ON NUCLEAR STRUCTURES FOUNDED ON ROCK SITES

Fully integrated simulation and design process for offshore wind turbines including support structures

Determination of damage location in RC beams using mode shape derivatives

POWER PRESSES. Vibration Control, Mounting and Levelling of: Power Presses APPLICATIONS. Presses come in various categories including:

Transcription:

TONAL NOISE MITIGATION ON WIND TURBINES Jutta M. Stauber, Brett A. Marmo and Donald Black Xi Engineering Consultants Ltd, Edinburgh, UK email: juttastauber@xiengineering.com Free layer damping tiles were applied to the tower of a wind turbine, whose problematic tone of ~350 Hz was amplified by resonant vibrations of the tower. IEC 61400 measurements before and after the installation of the damping tiles showed that the audibility of the problematic tone was reduced by 3 db and a broadband noise reduction of 3 db was also observed. Several steps were carried out to determine that free layer damping was a suitable solution for this wind turbine. Firstly, acoustic and vibration surveys were carried out to ensure that the problematic tone was, indeed, amplified by the tower. Secondly, as a means of de-risking the application of the solution, structural-acoustic finite element models were created. These were used to predict the modal shape of the tower and consequently to determine the number and placement of tiles necessary to reduce the tone. After the installation of the tiles on the tower, acoustic and vibration measurements were carried out to determine their effectiveness on both reducing the amplitude of the resonant vibrations of the tower and the tonal and broadband noise of the turbine. Keywords: Tonality, Mitigation, Wind turbine, Free layer damping 1. Introduction Tones are very easily perceived by human hearing, so that tonal noise from wind turbines seems to increase the annoyance of receivers and has been identified as the primary cause for complaint [1]. Consequently, legislation has been put into place to regulate tonal noise emitted from wind turbines, which, if not adhered to can lead to financial penalties, curtailment and even closure of a turbine site. The risk of such economic losses has highly motivated the wind turbine industry to develop solutions to tonal noise. A tonal noise mitigation solution has been developed based on free layer damping of the wind turbine tower. This paper presents a case study where vibration measurement combined with finite element (FE) modelling showed that the principal radiation source of tonal noise was the tower wall. Polymer tiles were adhered to the walls of the wind turbine tower, thereby increasing their damping characteristics. This free layer damping solution reduced the amplitude of resonant vibrations responsible for amplifying tonal noise. A validation IEC 61400 measurement showed that the audibility of the tone was significantly reduced, and that the installation also lead to a broadband sound power level reduction. 2. Technical Background 2.1 Sources for and propagation of tonal noise produced by wind turbines Tonal noise in wind turbines is commonly caused by vibrations produced by the rotating components of the drivetrain. For example, vibration can be caused through the interlocking of gear teeth in the gearbox referred to as gear meshing. These vibrations, while causing tonal noise, [2] may not necessarily be problematic, as the drivetrain is often a considerable distance away from the nearest receiver. However, if the frequency of vibration is closely aligned with structural resonant frequen- 1

cies of the tower, then the tower s modal response can be excited, therefore amplifying and radiating tonal noise. Wind turbine towers are commonly lightly damped steel structures with very large surface areas, making them extremely efficient radiation surfaces for tonal noise. It should be noted that tonal noise can also be caused by the blades; however, in the present paper only tonal noise that is amplified by the tower shall be addressed. 2.2 Tonal mitigation solutions Tonal noise from wind turbines can be mitigated by either reducing the vibrations of the source or modifying the propagation of the noise to the receiver. Reducing the vibrations of the source can be achieved by exchanging the gearbox or other drivetrain components or setting the operating system to avoid frequency matching with the modal response of the tower. While these solutions can be very effective, they are likely to be impractical and involve significant economic investment or financial losses. There are several ways to modify the noise propagation from the turbine through the air to the receiver. This can be achieved by modifying the noise propagation through the air, for example, by restricting the turbine to operate in specific wind directions or placing acoustic barriers close to the receivers. As these solutions are also likely to be impractical and connected to significant economic losses, this paper shall focus on mitigation solutions where the propagation from the source, through the tower, i.e. the structural propagation through the tower, is modified. In particular, this is achieved by damping the tower walls, especially their modal response, so that tower wall surfaces will radiate vibration through the air, which is perceived as noise by the receiver. There are different mechanisms for damping the tower walls. One example is through the installation of a tuned mass damper (TMD) or multiple tuned mass dampers (MTMD), which are designed to reduce the vibration amplitude at the frequency they are tuned to or a range of frequencies about the tuning frequency. This is achieved by creating one (or two) new frequencies that have a higher or lower frequency than the frequency for which they are tuned [3]. Consequently, they are not broadband dampers. However, for turbines with a variable running speed this can lead to new resonances being excited and, hence, tonal noise simply being shifted to different frequencies. For turbines with a variable running speed it is, therefore, better to install a broadband damper. Examples of broadband dampers that can be applied to wind turbines are free layer damping, constrained layer damping and advanced particle damping (APD) [4]. Free layer damping is the focus of this paper and is discussed in depth below. Constrained layer damping involves the adhesion of one or more layers of damping material (commonly a polymer) to the tower wall and a rigid layer (commonly steel) adhered outside the polymer. For constrained layer damping vibration energy is dissipated via heating as the polymer layer is forced to shear between the two rigid surfaces [5]. APD involves polymer particles within a container, where vibration energy is dissipated via friction between particles and via their internal deformation [5]. An advantage of APD is that containers can be constructed with magnetic attachments that allow their installation within a wind turbine without adhesives. For narrow turbine towers a layer solution maybe more practical than the APD pods as the containers have a longer depth than the thickness of the tiles. 2.3 Free layer damping Free layer damping is very similar to constrained layer damping. However, for free layer damping (sometimes also called extensional damping) typically only a single layer of damping material is attached with a strong bonding agent to the surface of a structure. As the damping material extends and compresses due to the flexural stress of the underlying structure, energy is dissipated. Thus damping tiles are most effective when placed on areas with high displacement. The effectiveness of the damping also depends on the thickness and composition of the damping material layer. In order to protect the damping material tiles from being exposed to the elements, they should to be applied on the inside of the tower. This complicates the installation of the layers as fumes from the bonding agent may be released into a confined space. 2 ICSV24, London, 23-27 July 2017

However, as free layer damping involves less material than constraint layer damping, costs are reduced. Furthermore, the damping provided through the single layer may be enough to reduce the tonal noise sufficiently to the desired levels. For these reasons the free layer damping solution was chosen to be implemented. 3. Methodology A case study of a turbine that operates at two fixed speeds depending on the wind speed is presented. Several steps involving vibration and acoustic surveys on and FE modelling of this turbine were used to determine that free layer damping was a suitable solution for reducing the audibility of tonal noise. Finally, after the installation of the free layer damping tiles further acoustic and vibration surveys were conducted to quantify the reduction in the tower vibration and, hence, the tones in the field. Vibration measurements were used to determine vibration pathways and to determine if the measured tones were related to tower resonances. A concurrent acoustic survey was conducted. Note the acoustic measurements, calculation of the sound power level and the reporting of the tones were done in accordance with the IEC 61400-11. The surveys also showed that the problematic tones occurred for low wind speeds, when the turbine was operating at a lower fixed speed; hence results for the turbine operating in the higher fixed speed are not presented. As the vibration and acoustic survey showed that high levels of excitation of the tower levels correlated with the problematic tones, it was determined that damping the tower walls could reduce tonal noise. A broadband damping solution was desirable, as tones were noted for the turbine operating at the low and high fixed speed, albeit with the tones not being problematic when the turbine operated in the higher fixed speed. Thus, applying a TMD solution was eliminated, leaving the APD pod solution and a damping layer solution as possible candidates. As the tower had a maximum diameter of 2 m, the installation of APD pod solution was less practical due to the depth of the container. For a commercial reasons the free layer damping solution was chosen to be installed instead of the constrained layer damping solution. To de-risk the process of installing the solution by ensuring that the reduction of tones is possible, an FE model was created. A structural-acoustic model of the existing turbine was created in COMSOL Multiphysics and calibrated with the measured data. In particular, a 3D model of the turbine was created with the tower sections, blades and nacelle walls modelled as shell elements and the drivetrain components as solid elements. The model was excited using force related gear meshing, with the turbine being fixed to the ground. The tower was modelled to be steel, and the blades and nacelle walls as fibreglass composite. The material properties of the drivetrain components were modelled such that modelled properties reflected the properties of the turbine. The purpose of the model was primarily to determine the modal shape of the tower at the problematic frequency, as damping tiles are most effective when being placed on areas of with a high displacement. The model predicted that areas of high displacement for this turbine were located at the bottom of the tower. Having determined its modal shape, models were developed to quantify the effect of placing damping tiles on the tower walls. In particular, the damping tiles were modelled to be part of the tower shells with modified material properties determined through sub-modelling. Thus several different coverage strategies of the tower walls with damping tiles were modelled, including a coverage of the bottom section, the bottom and top section, and a full coverage, and the sound pressure level predicted was predicted. After the installation of the damping tiles, a survey was conducted to determine the vibration and tonal reductions and if the solution reduced the tonal audibility to the desired values. To allow for a comparison with the results before the installation the acoustic survey was also done in accordance to the IEC 61400-11 standard. ICSV24, London, 23-27 July 2017 3

4. Results 4.1 Initial acoustic and vibration survey An initial acoustic survey conducted according to the IEC 61400-11 standard showed that the turbine had a several problematic tones, including the worst near 350 Hz and its harmonic near 700 Hz. This tone is shown in the top figure in Figure 1, which shows the unscaled power spectral density of audio signal. This frequency correlates with one of the gear meshing frequencies and a prominent peak in the vibration spectra recorded the bottom of the tower (middle and bottom figures in Figure 1). Based on these correlations, it was determined that the 350 Hz tone was generated by gear meshing, transmitted into the tower and subsequently radiated into the air. The gear meshing frequency was calculated from the rotational speed and the number of gear teeth. Thus, it was concluded that a tower damping solution is likely to be very effective in reducing the audibility of the tone. Figure 1: Tone at approximately 350 Hz. This frequency is related to one of the gear meshing frequencies, resulting in high levels of vibration of the gearbox. At this frequency high levels of vibration can also be observed at the bottom of the tower. 4.2 Finite element model The finite element model was created to predict the modal response of the tower and the sound pressure level at the IEC position that is the observer position on the ground downwind from the turbine at a distance of tip height. Mitigated solutions where damping tiles were placed on different sections of the tower were also modelled to predict if the solution would be effective in the field. Figure 2 shows the predictions for the turbine with and without mitigation solutions of the structural FE model of the normal acceleration of the tower at 353 Hz, which is representative of the problematic frequency observed in the initial acoustic and vibration survey. It shows that for this frequency the modal shape of the tower is such that the bottom section of the tower has the highest acceleration and will therefore amplify the problematic tone the most. This indicates that in order to effectively mitigate the tone, the damping tiles should be installed on the bottom sections of the tower. 4 ICSV24, London, 23-27 July 2017

Free layer damping is most effective when the tile coverage is greater or equal to the wave length of the modal shape (i.e. twice the distance between nodes). The FE model was used to determine that the spatial wavelength of the 350 Hz vibration was ~ 1 m (Fig. 2). Free layer damping tiles were therefore designed such that the continuous coverage on each turbine tower panel exceeded 1 m. To determine if the tiles would be effective at decreasing the tonal noise, several mitigation solutions were modelled, namely covering the bottom, the top and the bottom and the complete tower with damping tiles. The model predicted that for frequencies between 100 and 600 Hz all the mitigation solutions applied to turbine would be effective at reducing the problematic tone (Fig. 2). For commercial reasons it was decided to install damping tiles covering the bottom and the middle section of the tower. Figure 2: Predicted normal acceleration of the tower at 353 Hz for native turbine (left), turbine with damping tiles applied on the lower sections (2 nd from left), turbine with damping tiles applied on the lower and top sections (2 nd from right) ), turbine with damping tiles applied across the whole tower (right). For the native turbine, the highest acceleration occurs in the bottom section of the tower. 4.3 Acoustic and vibration verification survey After the installation of the damping tiles, a second measurement campaign was conducted. The results of these acoustic and vibration measurements of the mitigated turbine were compared to the results from the measurements prior to the installation free layer damping tiles. The aim of this comparison was to determine the effectiveness of the damping tiles and their ability to reduce the modal response of the tower wall and the related sound power level and audibility of tonal noise. Figure 3 gives a representative example of the response of the native and mitigated towers after being excited with an impact hammer. The dotted line represents the problematic frequency (approx. 350 Hz) for which the tower was damped. It also shows that the damping is not only effective for the problematic frequency, but also for most frequencies between 200 and 600 Hz. In particular, it shows that the free layer damping material is indeed effective over a broad range of frequencies. The acoustic output of the native and mitigated turbines were measured in accordance with the IEC 61400-11 standard. Comparing the audibility of the tonal noise before and after the installation of the damping tiles shows that the audibility of tonal noise was significantly reduced after the installation (Fig. 4). An example of a comparison between the audibility of tones for the native and mitigated turbine is shown in Figure 4 for the 9 m/s wind speed bin; all wind speeds are extrapolated to hub height. The black dashed lines denote the audible tone threshold (0 db) and the threshold ICSV24, London, 23-27 July 2017 5

for when to report a tone (-3 db). The most audible tone, with an audibility of approx. 6.9 db for the native turbine, at approximately 350 Hz is reduced to 4.0 db; the other audible tone at approximately 700 Hz is also significantly reduced by 5.5 db. Figure 4 shows that the application of the damping tiles not only reduces the audibility of the tone at 350 Hz, but also reduce all other tones in the 100 to 700 Hz range to inaudible (Fig. 4). Furthermore, the tones at 3150 Hz and 3300 Hz detected for the native turbine were not detectable when the mitigated turbine was measured (Fig. 4). Note, although not shown here, the most prominent tone at 350 Hz was reduced by approximately 3 db across all wind speed bins. The reduction in tonal noise audibility was accompanied by a commensurate reduction in broadband noise. The broadband sound power level of the mitigated turbine was reduced by ~3 db across all wind speed bins measured (Figure 5). Note, for the mitigated turbine only wind speed bins between 6 m/s and 10 m/s were measured. Figure 3: Power spectral density of the bottom of the native and mitigated tower after being excited by an impact hammer. The dotted line represents the problematic frequency for which the tower was damped. 6 ICSV24, London, 23-27 July 2017

Figure 4: Tonal audibility as a function of frequency for the 9m/s wind speed bin (extrapolated to hub height). Figure 5: A-weighted sound power level as a function of wind speed bin (extrapolated to hub height) for the mitigated and native turbine. 5. Discussion The coverage of the tower with damping tiles is related to the tonal audibility reduction. The greater the area covered by the damping tiles the greater the tonal audibility reduction. Thus damping tiles can be installed stepwise. Should further reductions be required, additional tiles could be installed or the free layer damping could be modified into a constrained layer damping solution by applying metal layers onto the polymer tiles. ICSV24, London, 23-27 July 2017 7

The effectiveness of the present solution is limited to turbines for which the tones are amplified by tower resonances. In cases when the tonal noise is not amplified by tower resonances, but for example by the blades, the tower wall mitigation is likely to be not effective. 6. Conclusion A case study of the wind turbine was presented which outlined how initial acoustic and vibration surveys together with FE modelling were used to predict that free layer damping could be an effective solution to reduce the tonal audibility of the wind turbine. After the installation of damping tiles on the tower of the turbine, acoustic and vibration measurements demonstrated that the mitigation was successful. In particular, an average tonal audibility reduction of 3 db was found in the field for the most prominent tone and resulting in a broadband noise reduction also of 3 db. Results of the vibration survey found that tiles decrease vibration levels over a broadband range of frequencies (approx. 200-600 Hz) and, therefore, could be used for many tonal noise problems, especially for tonal wind turbines with a variable running speed. REFERENCES 1 ETSU-R-97. The assessment and rating of noise from wind farms, Final report of the Working Group on Noise from Wind Turbines, ETSU-R-97, ETSU, Harwell, UK (1996) 2 Burton, T., Sharpe, D. and Jenkins, N. Wind Energy Handbook, John Wiley & Sons, Chichester, England (2001). 3 Lin, C. C., Lin, G. L. and Lung H.Y. Dynamic test of multiple tuned mass dampers for vibration control of high-rise buildings, Tenth U.S. National Conference on Earthquake Engineering, Frontiers of earthquake engineering, Anchorage, USA, 21-25 July (2014). 4 Ott, M., Weisbeck, J., Gerges, S. N. Y. and Bustamante, M. The effectiveness of particle damping for use on vertical surfaces, Internoise, Melbourne, Australia, 16 19 November (2014). 5 Marmo, B. A. and Carruthers, B. J. Modelling and analysis of acoustic emissions and structural vibration in a wind turbine, COMSOL Conference Proceedings, Paris, France, 17 19 November, (2010). 6 Stauber, J., Marmo, B., Ott, M., Snaith, M. and Puff, M. Wind turbine noise attenuation using modal structural damping, Internoise, Hamburg, Germany, 21-24 August (2016). 8 ICSV24, London, 23-27 July 2017