Fire Safety with Concrete Products

Similar documents
Fire Safety with Concrete Masonry Products. NCMA/AIA CES COURSE C202a

FIRE RESISTANCE OF NORLITE EXPANDED SHALE CONCRETE MASONRY

Exception: All layers of single and multilayer reflective plastic core foil insulation shall comply with Section 2604.

Fire Inspection and Code Enforcement, 7 th Edition. Chapter 6 Building Construction: Components Inspector II

FCIA Webinar Gypsum Wall Patching

Engineering Analysis of NFPA 285 Tested Assemblies

2012 IBC Inspection of Fire-Resistance Rated Floors, Ceilings and Roofs

Protecting Penetrations in Fire Rated Construction

CHAPTER 26 PLASTIC SECTION BC 2601 SECTION BC 2603 GENERAL FOAM PLASTIC INSULATION

Building Codes and Ordinances ARC 227

2012 IBC Inspection of Fire-Resistance Rated Floors, Ceilings and Roofs

2015 IBC Inspection of Fire-Resistance Rated Floors, Ceilings and Roofs

FIRE AND SMOKE PROTECTION FEATURES

CHAPTER 26 PLASTIC SECTION 2601 SECTION 2603 GENERAL FOAM PLASTIC INSULATION

65% Waste Output. 12% Water Use. 70% Electricity Consumption. What is the size of your footprint? Concrete Masonry Sustainable Construction

Fire Resistance and Protection of Structures


Combustible Exterior Wall Cladding Systems: An ICC Perspective

FIRESTOP 101: An Introduction to Firestopping

ALLOWABLE STRESS DESIGN OF CONCRETE MASONRY LINTELS. TEK 17-1C Structural (2009) Related TEK: Uniform load. Triangular load. Concentrated loads

FIRE AND SMOKE PROTECTION FEATURES

The Building Codes A.R.E. Building Design and Construction Exam Prep

FIRE ENDURANCE RATINGS CLAY BRICK MASONRY

FIRE AND SMOKE PROTECTION FEATURES

FS , 712, 713, 714

INTERIOR FINISHES CHAPTER 8

CANADA SPECIFIC FIRESTOPPING REQUIREMENTS

Managing Vertical Fire Spread in Multi-Story Buildings Through Effective Perimeter Fire Barrier Systems

Module 8: Ontario Building Code Fire and Spatial Separations

Comparison of the life safety elements of the 1997 UBC and the IBC 2000.

PRESCRIPTIVE COMPLIANCE METHOD

INTERIOR FINISHES CHAPTER 8

First Revision No NFPA [ Section No ]

Jean Vaillancourt Fire Protection Specialist Hilti (Canada) Corp.

SPECIAL DETAILED REQUIREMENTS BASED ON USE AND OCCUPANCY

Fire Resistive Construction

SECTION : FIRE WALL AND FIRE SUPPRESSION REGULATIONS FOR R1-Z, R-2, R-3 ZONING AND PDD CATEGORIES

SPECIFICATION DIVISION 7 NUMBER SECTION DESCRIPTION DIVISION 07 THERMAL AND MOISTURE PROTECTION SECTION THROUGH-PENETRATION FIRESTOP SYSTEMS

Outcomes of ICC Tall Wood Ad Hoc Committee: Proposals and Discussion

HOT SPRINGS FIRE DEPARTMENT EVALUATION OF DOWNTOWN LEGACY STRUCTURES Savoy Hotel Thompson Building Dugan Stewart Building May 16, 2012

Applying the Building Code During Design

First Revision No NFPA [ Section No ]

INTERIOR FINISHES CHAPTER 8

Building Code 8 th Edition

CALIFORNIA COMMERCIAL BUILDING INSPECTOR CONTENT OUTLINE 01. GENERAL ADMINISTRATION 6% Project Administration 1%

June 7, 2012 PARTIES INTERESTED IN HVAC DUCT ENCLOSURE ASSEMBLIES

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: WATER RESISTIVE BARRIERS/WEATHER BARRIERS SECTION: AIR BARRIERS

SPECIFICATION GUIDE. thin glazed brick

NCMA TEK TEK 19-5A FLASHING DETAILS FOR CONCRETE MASONRY WALLS

What is a Won-Door FireGuard Door?

APPLICATION AND CERTIFICATE FOR PAYMENT

SPECIFICATION GUIDELINE

WOOD USE IN NONCOMBUSTIBLE BUILDINGS

IBC FIRE SAFETY. Code Change No: FS1-07/08. Original Proposal SECTION 702 DEFINITIONS

Responsibilities: Effective Date: November Revision Date: January 27, VP, Facilities and Construction Management

Plan Check No. Checked by: An Appointment Is Required for Verification

HCD DSA OSHPD 1 2 1/AC AC SS SS/CC CALIFORNIA BUILDING CODE 301

DIVISION 04 MASONRY. Section Title Number MASONRY Maintenance of Masonry Masonry Mortaring Masonry Accessories

SECTION THROUGH-PENETRATION FIRESTOP SYSTEMS

Special Inspector Examinations (continued)

1. Frozen food warehouses used solely for storage of Class I and II commodities where protected by an approved automatic sprinkler system.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: ICYNENE, INC.

Statement of Special Inspections Michigan Building Code 2012 (MBC 2012)

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION SECTION: WATER-RESISTIVE BARRIERS/WEATHER BARRIERS

Accessible Means Of Egress

ESR-2072 Reissued September 1, 2013 This report is subject to renewal September 1, 2015.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: DEMILEC (USA) INC.

Code Compliance Research Report CCRR-0228

DURRELL DESIGN GROUP, PLLC ROOF REPLACEMENT BARR ELEMENTARY SCHOOL JACKSON PUBLIC SCHOOL DISTRICT JACKSON, MISSISSIPPI.

780 CMR: 9 th Edition Massachusetts State Building Code. Presented to: BSA Codes Committee. DATE: January 20, 2016

Code Requirements for Existing Buildings. R. W. Sullivan, Inc. 529 Main St., Suite 203 Charlestown, MA (617)

October 12, Yours very truly, Gary G. Nichols, P.E., SECB Vice President. GGN/md Enclosure Evaluation Committee

Fire Behaviour in Different Building Types

Publications & Technical Reference Material

Code Requirements for Existing Buildings. R. W. Sullivan, Inc. 529 Main St., Suite 203 Charlestown, MA (617)

CTP STITCH-TIE AGAIN! Quick and easy way to re-anchor existing veneers to back-up structures.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: METAL WALL PANELS REPORT HOLDER: METL SPAN, A DIVISION OF NCI GROUP, INC.

FS103 06/ (New), (New), (New), (New)

Definition of Wall. A continuous, vertical structure Thin relatively to its length and height

DIVISION: MASONRY SECTION: MANUFACTURED BRICK MASONRY SECTION: MANUFACTURED STONE MASONRY REPORT HOLDER:

DIVISION: CONCRETE SECTION: SPECIALTY PLACED CONCRETE REPORT HOLDER: EMMEDUE S.P.A.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: WATER RESISTIVE BARRIERS/WEATHER BARRIERS SECTION: AIR BARRIERS

SPECIFICATION GUIDELINE

JC Code & Construction Consultants, Inc. Advanced 2010 FBC Update Ch. 1 to 16

BICSI March 19 th, 2009 Canadian Regional Meeting NBCC Moncton, New Brunswick. Firestop, it s not Magic It s understanding!

Building Standard V1.1

Image courtesy of KTGY, Inc. ENGINEERED FOR FIRE CODE COMPLIANCE AND DESIGN FLEXIBILITY

REFLECTIVE FACE CONCRETE MASONRY UNITS

SPACE TYPE: OUTSIDE PARKING (STRUCTURE)

Appendix 3G Wood First Matrix

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: ROOFING AND SIDING PANELS REPORT HOLDER: KINGSPAN INSULATED PANELS, INC.

REPORT HOLDER: HILTI, INC DALLAS PARKWAY, SUITE 1000 PLANO, TEXAS EVALUATION SUBJECT: HILTI LOW-VELOCITY POWER-ACTUATED FASTENERS

St. Monica Food Pantry

UNIFIED FACILITIES GUIDE SPECIFICATIONS

MCCARTY ARCHITECTS, P.A. POST OFFICE BOX 440 / 533 WEST MAIN STREET TUPELO, MS / FOR ANSWERS TO QUESTIONS CONTACT: JUSTIN HARRINGTON

DIVISION 7 THERMAL AND MOISTURE PROTECTION SECTION PENETRATION FIRESTOPPING

Transcription:

Fire Safety with Concrete Products by Bill McHugh & Rich Walke representing National Concrete Masonry Association May 12, 2014 FCIA TJC ASHE UL Barrier Management Symposium King of Prussia, PA

Referenced NCMA TEK TEK 5-8B: Detailing Concrete Masonry Fire Walls TEK 7-1C: Fire Resistance Rating of Concrete Masonry Assemblies TEK 7-2: Balanced Design Fire Protection TEK 7-3A: Firestopping for Concrete Masonry Walls TEK 7-4A: Foam Plastic Insulation in Concrete Masonry Walls All available free on line see www.ncma.org for list of sponsors and links

Components of Balanced Design 1 Automatic Detection Systems (Alarms) 2 Automatic Suppression Systems (Sprinkler Systems) 3 Compartmentation - using noncombustible materials (Concrete Masonry)

Firewall Performance

Firewall Performance

Firewall Performance

Consequence of No Firewalls

New Orleans Fire

Independent Support and Breakaway Connectors to revent Firewall Collapse

Robustness Egress Protection Exit Hardened walls Stair and Elevator Shafts

Concrete Fire Ratings ASTM E 119 Three methods for determining ratings: 1. Fire Testing 2. Listing Service 3. Calculation Method

Concrete Fire Ratings Per the Building Code Three methods for determining ratings: 1. Fire Testing 2. Listing Service 3. Calculation Method Underwriter s Laboratories UL 618 UL Standard for Safety for Concrete Masonry Units

ASTM E119 Fire Rating Criteria Structural failure to support load Passage of heat or flame sufficient to ignite cotton waste Temperature rise on the unexposed surface 250 degrees F over ambient Failure under hose stream - walls and partitions

Concrete Masonry Fire Ratings Fire Test Data - Calcareous and Siliceous Aggregate 3. Calculation Method Equivalent thickness (in) 9.00 8.00 7.00 6.00 5.00 4.00 3.00 2.00 1.00 0.00 0 50 100 150 200 250 Fire Resistance (minutes)

Calculated Fire Resistance Method Fire ratings for concrete products are a function of: Aggregate type Equivalent thickness

ACI 216.1 / TMS 216 Applicable to: Concrete Concrete masonry Clay brick and tile masonry Effects of finish materials on fire resistance Incorporated into the I- Codes

Equivalent Thickness Equivalent Thickness, T e, is the solid thickness that would be obtained from the same volume of concrete without cores. T e = % solid x actual thickness

Applicable NCMA TEK on Fire Resistance* TEK 7-1C: Fire Resistance Rating of Concrete Masonry Assemblies TEK 7-3A Firestopping for Concrete Masonry Walls TEK 7-5B: Evaluating Fire Exposed Concrete Masonry Walls TEK 7-6: Steel Column Fire Protection *All are available free on-line through www.ncma.org

Filling Cores When the hollow cores of concrete masonry are filled, the equivalent thickness is considered to be the actual thickness of the concrete masonry unit. Thus all filled 8-inch and many 6-inch CMU have 4 hour ratings.

Finishes Finishes are an excellent way of increasing the fire resistance rating of existing assemblies

Repairs to Concrete and Masonry Concrete, mortar, and grout are generic listed fire resistant materials that can be used for repairs and firestopping within the limitations of the code.

Control Joints TEK 7-1C

Control Joints 4 hour rated joints for masonry Concrete similar to top figure Chart indicates amount of insulation TEK 7-1C

Glazed Units The calculated fire resistance rating procedure for a glazed unit is the same as for conventional units- Same charts based on equivalent thickness and aggregate type.

Clay Brick and Tile The IBC and ACI/TMS 216 standard also address calculated fire resistance rating for clay brick and tile masonry wall assemblies (very similar to the concrete masonry tables and procedures).

IBC NFPA 285 Requirement IBC 2603.5.5 Vertical and lateral fire propagation. The exterior wall assembly shall be tested in accordance with and comply with the acceptance criteria of NFPA 285. TEK 7-4A

IBC NFPA 285 Requirement Exception: 1. One-story buildings complying with Section 2603.4.1.4. 2. Wall assemblies where the foam plastic insulation is covered on each face by a minimum of 1-inch (25 mm) thickness of masonry or concrete and meeting one of the following: a. there is no air space between the insulation and the concrete or masonry; or b. the insulation has a flame spread index of not more than 25 as determined in accordance with ASTM E 84 or UL 723 and the maximum air space between the insulation and the concrete or masonry is not more than 1-inch (25 mm). TEK 7-4A

Exterior Generated Fires

Monte Carlo Hotel Las Vegas Jan. 24, 2008

Cost Comparison Study

Cost Comparison Study The original study was conducted in MA, PA, MD, NY. However, supplements were issued later for 31 additional cities across the US.

Cost Comparison Study Conclusion Cost of compartmentalized construction using a concrete based material is generally less than 5 percent of the overall construction cost and in some cases there is no increased cost. See: http://www.pafscac.org/

Summary Concrete products provide robustness and added protection Fire ratings are easily determined by the various methods available. Compartmentation is effective and it doesn t cost as much as people think.

Questions Thank you for your time! 13750 Sunrise Valley Drive Herndon Virginia 20171 Phone 703-713-1900 Fax 703-713-1900 www.ncma.org