NCMA TEK RESIDENTIAL DETAILS FOR HIGH WIND AREAS. TEK 5-11 Details (2003)

Similar documents
STRUCTURAL ISSUES IN RESIDENTIAL CONSTRUCTION. Presented by: Susan L. Lasecki P.E., S.E.

NCMA TEK TEK 19-5A FLASHING DETAILS FOR CONCRETE MASONRY WALLS

CHAPTER 3 BUILDINGS WITH WOOD FRAMED EXTERIOR WALLS 301 SCOPE

ACCESSORY STRUCTURE Building permit information For 1 & 2-family dwellings

130 MPH EXPOSURE B WFCM GUIDE. Guide to Wood Frame Construction in High Wind Areas for One- and Two-Family Dwellings 2015 EDITION

ASD OF CONCRETE MASONRY LINTELS BASED ON THE 2012 IBC/2011 MSJC. TEK 17-1D Structural (2011) Related TEK: 14-7C, 14-13B, 17-1C, 17-2A

WFCM 130 MPH GUIDE EXPOSURE B WOOD FRAME CONSTRUCTION MANUAL GUIDE TO WOOD CONSTRUCTION IN HIGH WIND AREAS FOR ONE- AND TWO-FAMILY DWELLINGS

Wall bracing panel requirements

Anchor bolts ASTM F1554, Gr. 36 Wide flange beams ASTM A992, Fy = 50 ksi Misc. structural steel ASTM A36, Fy = 36 ksi

R Code and Commentary for 2012 NC Residential Code final 03/06/13

Colorado Chapter of the International Conference of Building Officials. Building Guide. The Colorado Chapter of the International

GARAGES/ONE-STORY City of Grand Rapids Building Safety Division

Details for Exterior Brick Masonry Veneer Supported by Metal Plate Connected Wood Trusses

2012 Wood Frame Construction Manual: Wind Load Distribution on Buildings Load Paths

2003 International Residential Building Code

CALCULATING WIND LOADS ON LOW-RISE STRUCTURES PER 2015 WFCM ENGINEERING PROVISIONS (STD342-1)

BROCHURE # 108 CONSTRUCTION PLAN COMPONENTS

POST FRAME BUILDING STANDARDS

TYPICAL BEARING WALL FRAMING

Wood Frame Construction Manual for One- and Two-Family Dwellings 2015 EDITION WORKBOOK

TOWN OF SOUTH KINGSTOWN REQUIREMENTS FOR BUILDING PERMITS RESIDENTIAL SINGLE FAMILY

Frame Wood Systems. Prepared for Forest Product Laboratory, Forest Service, U.S. Department of Agriculture National Association of Home Builders

Minimum Requirements For One & Two Family Structures FBC 6 th Edition (2017)

Heel Blocking Requirements and Capacity Analysis. Overview Revised 3/22/2017

ALLOWABLE STRESS DESIGN OF CONCRETE MASONRY LINTELS. TEK 17-1C Structural (2009) Related TEK: Uniform load. Triangular load. Concentrated loads

POST AND FRAME STRUCTURES (Pole Barns)

FACT SHEET #2 DECK INFORMATION

INSULATION RETROFIT DESIGN ENERGY SOLUTIONS CENTRE YUKON GOVERNMENT

R CODE CHANGE PROPOSAL FORM (See instructions on page 2)

Proposed Modification to the Florida Building Code

RB104-09/10 R602.7, R (New), Table R (New), Figures R (1)-(2) (New)

Custom 24 x 26 Garage Plan Roy Hartmann Plan #g218 By SDS-CAD Specialized Design Systems CLIENT

Chapter 2 EARTHQUAKE-RESISTANCE REQUIREMENTS

Administrative Changes

1 AND 2 FAMILY DWELLING REQUIREMENTS

fifteen design for lateral loads Lateral Load Resistance Load Direction Lateral Load Resistance

FEMA P-593 STEP-BY STEP PRESCRIPTIVE RETROFIT FOR CRIPPLE WALL BRACING & ANCHORAGE TO FOUNDATION

City of Hughson Building Safety Division 7018 Pine Street Hughson, CA (209)

HILLSBOROUGH TOWNSHIP CODE ENFORCEMENT

10 EXTREME BASEMENT PANELS

Interior Hangers. Application

Structural System. Design Criteria Fire Resistance Concrete designed for 2 HR rating (worst case) Geotechnical Report Allowable Bearing Capacity

The Structural Redesign of Boyds Bear Country and its Related Systems. Boyds Bear Country, Pigeon Forge, Tennessee

Foundations in Coastal Areas

SECTION PLATE CONNECTED WOOD TRUSSES

Contents. 1.1 Introduction 1

DETAIL DRAWINGS. RASTRA is a stay-in-place insulated concrete. form that is structurally strong, energy-efficient,

See the IRC for additional information. See CPD-DS Information Bulletin 100 for Requirements for 1 & 2 Family Dwelling plan submittals.

Structural Inspection

WALL CONSTRUCTION CHAPTER 6

Prepared for Forest Product Laboratory, Forest Service, U.S. Department of Agriculture Norbord Inc., Toronto, Ontario, Canada

BARN MAIN FLOOR PLAN. #G457a 12 x 20 x 8 Gentleman Bunkhouse Shed By SDS-CAD Specialized Design Systems 12'-0" 3'-0" 4'-0" 1'-6" 3'-0" 1'-6" 20'-0"

4.6 Procedures for Connections

POST AND FRAME STRUCTURES (Pole Barns)

ESR-2894 Reissued April 2014 This report is subject to renewal April 1, 2016.

SCREEN PORCHES 101 DEVELOPMENT RESOURCES, INC Permit Requirements

Open-Web Trusses. Including Red-L, Red-W, Red-S, Red-M and Red-H Trusses. Design Flexibility. Outstanding Strength-to-Weight Performance

A Guide for the Interpretation of Structural Design Options for Residential Concrete Structures

MBOIA IRC Wall Bracing. Mark Halverson. Maine Building Officials and Inspectors Association. First Last

Statement of Special Inspections Michigan Building Code 2012 (MBC 2012)

Brick Veneer / Wood Stud Walls

SIPs over a steel frame Raised SIP floor

Plan Check No. Checked by: An Appointment Is Required for Verification

FIGURE R502.2 FLOOR CONSTRUCTION

On Cold-Formed Steel Construction. Light Gauge Steel Engineers Association Washington, D.C Toll Free (866)

two structural systems, planning and design Structural Organization Bearing Walls Structural Components

CALIFORNIA COMMERCIAL BUILDING INSPECTOR CONTENT OUTLINE 01. GENERAL ADMINISTRATION 6% Project Administration 1%

EMERGENCY MANAGEMENT PREPAREDNESS AND ASSISTANCE TRUST FUND ARC 4496 Evaluation Questionnaire

1/31/2013. OWTFA - Metal Plate Connected Wood Trusses

CITY OF CEDAR FALLS DEPARTMENT OF DEVELOPMENTAL SERVICES INSPECTION SERVICES DIVISION PHONE Residential Accessory Structures

A Simple Solution for Meeting

Table of Contents. Page Title

Calculated Quantities and Details

Prescriptive Design for Pole Barns Using the Larimer County Prescriptive Handout

Lateral load basics Code acceptance of Standard. Standard Overview 2008 Wind & Seismic Standard. Wind. Wind Load Path. IBC Section 1604.

4 EXTREME FOUNDATION PANELS

One and Two Family Additions

MAT109: Introduction to the Wood Frame Construction Manual

WASHINGTON STATE ENERGY CODE, APPENDIX CHAPTERS

Diaphragms 2. Design Process. Design Process. Diaphragms are the roofs and floors of the upper stories

Residential Building Inspections

REPORT HOLDER: FASTENING SPECIALISTS, INC. 726 CENTRAL FLORIDA PARKWAY ORLANDO, FLORIDA EVALUATION SUBJECT:

Supplemental Plan Check Corrections Sheet for Structural Design - General (2011 LABC)

REINFORCING TABLES INSTALLATION MANUAL

City of Republic Community Development Girder and Header Spans for Exterior Walls

Water Penetration Resistance - Design and Detailing

STRATEGIES FOR TERMITE RESISTANCE TEK 3-9A

Copyright. magazine. CFS Load Bearing Construction

2012 International Building Code Errata (Portions of text and tables not shown are unaffected by the errata)

Gold Bond BRAND Gypsum Sheathing

Technical Notes 28 - Anchored Brick Veneer, Wood Frame Construction Rev August 2002

The better way to build TM. Installation Manual FOUNDATION SIPs & FROST WALLS SIPs

Technical Notes 24G - The Contemporary Bearing Wall - Detailing [Dec. 1968] (Reissued Feb. 1987) INTRODUCTION

REPORT HOLDER: HILTI, INC DALLAS PARKWAY, SUITE 1000 PLANO, TEXAS EVALUATION SUBJECT:

SECTION UNIT MASONRY SYSTEM

Building Guide. Colorado Chapter of the International Code Council

SEISMIC STRENGTHENING PROVISIONS FOR UNREINFORCED MASONRY BEARING WALL BUILDINGS

STRUCTURAL DESIGN CRITERIA TABLE OF CONTENTS

Technical Notes 11B - Guide Specifications for Brick Masonry, Part 3 Rev [Feb. 1972] (Reissued Sept. 1988) INTRODUCTION

APPENDIX. WOOD JOIST/RAFTER MAXIMUM SPANS ( for 16 o.c. spacing) WITH SINGLE ROW OF PV PANELS AT MIDSPAN (ft.) AND PANEL SUPPORT AT 32 o.c.

Transcription:

NCM TEK National Concrete Masonry ssociation an information series from the national authority on concrete masonry technology RESIDENTIL DETILS FOR HIGH WIND RES TEK 5-11 Details (2003) Keywords: architectural details, construction details, continuous load path, high winds, reinforced concrete masonry, residential INTRODUCTION High winds subject buildings to large horizontal forces as well as to significant uplift. Reinforced concrete masonry is well suited to resist the large uplift and overturning forces due to its relatively large mass. High wind provisions generally apply to areas where the design wind speed is over 100 mph (161 km/hr) and over three second gust as defined by SCE 7 (ref. 10). The enclosed details represent prescriptive minimum requirements for concrete masonry buildings, based on Standard for Hurricane Resistant Residential Construction (ref. 3). CONTINUOUS LOD PTH Connections between individual building elements roof, walls, floors and foundation are critical to maintaining structural continuity during a high wind event. The critical damage to buildings in such events typically occurs due to uplift on the roof, resulting in the loss of crucial diaphragm support at the top of the wall. primary goal for buildings subjected to high winds is to maintain a continuous load path from the roof to the foundation. This allows wind uplift forces on the roof to be safely distributed through the walls to the foundation. If one part of the load path fails or is discontinuous, building failure may occur. Proper detailing and installation of mechanical connectors is necessary for maintaining continuous load paths. Note that in order for connectors to provide their rated load capacity, they must be installed according to the manufacturer s or building code specifications. In coastal areas, corrosion protection is especially important due to the corrosive environment. Note that water penetration details are not specifically highlighted in the following details. The reader is 1 No. 5 (M # 16) min. at each end of shear segments Beams spanning openings Shear segment 2 ft (610 mm) min. 1 No. 5 (M #16) min. at each side of opening having a horizontal dimension greater than 6 ft (1,829 mm) Top course reinforced bond beam continuous around perimeter Standard 90 hook at each vertical bar, typ. 1 No. 5 (M #16) min. at each corner and at each change in wall direction Vertical wall reinforcement at 4 to 32 ft (1,219 to 9,745 mm) o.c. depending on wall height, design wind speed and roof span. Footing dowel not always. Figure 1 Typical Reinforcement for High Wind reas Footing dowels at corners, openings wider than 6 ft (1,829 mm) and ends of shear segments, min. TEK 5-11 2003 National Concrete Masonry ssociation

Bond beam Horizontal reinforcement, Concrete masonry bond beam unit with part of interior face shell removed 8 ft (2,438 mm), max. Engineered wood roof trusses or rafters at 24 in. (610 mm) o.c., max. 12 Standard hook extended 6 in. (152 mm) into bond beam (min.) at each vertical wall reinforcement, typ. 1 4 in. (6 mm) expansion joint material and sealant Concrete slab Reinforced concrete footing Roof sheathing 12 max. Truss anchor rated for vertical uplift and horizontal loads perpendicular and parallel to the wall 24 in. (610 mm) max. overhang Concrete masonry wall Vertical reinforcement, 40 bar diameter lap, min. for Grade 40, 48 bar diameters for Grade 60. Grout, Figure 2 Exterior Loadbearing Wall Concrete masonry wall Concrete slab with 6 x 6, W 1.4 x W 1.4 (152 x 152 mm, MW 9 x MW 9) WWF*, extending at least 10 ft (3,050 mm) into slab and at least 6 in. (152 mm) into masonry bond beam Concrete footing Ceiling height 3 ft (914 mm), max. 8 ft (2,438 mm) when top of stem wall is tied to slab (see Figure 3) Vapor retarder * lternate: use No. 3 minimum at 4 ft (M# 10 at 1,219 mm) o.c. maximum extending into slab 10 ft (3,050 mm) min. and hooked into bond beam Reinforcement, Figure 3 Slab Connection for Foundation Wall 3 to 8 ft (914-2,440 mm) bove Grade referred to references 7 through 9 for more information on preventing water penetration in concrete masonry walls. In addition to a continuously reinforced bond beam at the top of the wall around the entire perimeter of the building, vertical reinforcement must be placed throughout a wall to resist the high uplift loads and provide continuity, including: at corners and wall intersections; on each side of openings wider than 6 ft (1,829 mm); at the ends of shear segments; and where girders or girder trusses bear on the concrete masonry wall (refs. 3, 4). Each of the exterior walls on all four sides of the building and all interior walls designed as shear walls must have at least one 2 ft (610 mm) minimum section of wall identified as a shear segment to resist the high lateral loads. Longer shear segments are more effective and are recommended where possible or by design. See Figure 1 for a summary of reinforcement requirements (ref. 3). Reinforcement must be properly spliced to provide load path continuity. Using allowable stress design, a splice length of 40 bar diameters is by Building Code Requirements for Masonry Structures (ref. 1) for Grade 40 reinforcement and 48 bar diameters for Grade 60 reinforcement. If the wall was designed assuming Grade 40 and Grade 60 was used for construction, however, the 40 bar diameter lap splice may still be used. See Steel Reinforcement for Concrete Masonry, TEK 12-4C (ref. 5) for standard hook requirements. DETILS Exterior Loadbearing Wall Figure 2 shows a typical loadbearing wall with a floating floor slab. Vertical reinforcement should be placed in the center of the concrete masonry cores to adequately resist both positive and negative wind pressures. Bond beam depth and minimum horizontal reinforcement varies with design wind velocity, ceiling height, roof truss span and spacing of vertical wall reinforcement. Since wind suction forces on the leeward side of a building can be

essentially as high as the pressure forces on the windward side, limitations are placed on the height above grade. However, if the slab is laterally supported and tied to the concrete masonry foundation wall as shown in Figure 3, the foundation wall may be extended to 8 ft (2,440 mm) above grade (ref. 3). Roof Truss nchor Figure 4 shows a typical roof truss anchor cast into the bond beam of a concrete masonry bearing wall. The anchor load capacity depends on the design wind speed as well as the roof truss span. In addition to being rated for uplift, the anchor must be rated for horizontal forces parallel to the wall (in-plane) and perpendicular to the wall (out-of-plane). Often, the direct embedded roof truss anchor method of connecting the roof to walls is preferred over the bolted top plate and hurricane clip method, as it generally has greater capacity and fewer connections. dditionally, the nail area available for the hurricane clip is limited by the thickness of the top plate. Bolted Top Plate s an alternate to the roof truss anchor, a bolted top plate may be used for the roof to wall connection (see Figure 5); however, anchor bolt spacing must be reduced (24 in. (610 mm) maximum) because the top plate is loaded in its weak direction. The detail illustrates several different connector types that are commonly used to connect the truss to the top plate. Gable End Walls Because of their exposure, gable end walls are more prone to damage than are hipped roofs unless the joint at the top of the end wall and the bottom of the gable (see Figure 6b) is laterally supported for both inward and outward forces. Figure 6a shows a continuous masonry gable end wall using either a raked concrete bond beam or a cut masonry bond beam along the top of full height reinforced concrete masonry gable end walls. s an alternative, a braced gable end wall can be constructed as shown in Figure 6b by stopping the masonry of the gable end at the eave height and then using conventional wood framing to the roof diaphragm. However, unless the end wall is properly braced to provide the necessary lateral support as shown in Figure 6b, this results in a weak point at the juncture of the two materials with little capacity to resist the high lateral loads produced by high winds. The number and spacing of braces depends on design wind speed, roof slope and roof span (ref. 2, 3, 6). Bond beam Grout stop F 2 Note: F 1, F 2 and F 3 are forces that must be accommodated in the design of the roof/wall connection. Connector (typ.) Connector may be bent and prenailed on bottom side if additional nailing area is F 3 F 1 Concrete masonry wall Figure 4 Roof Truss nchor Pressure treated Southern pine #2 or better top plate, as (2 x 4 min.) F1 F 2 Note: F 1, F 2 and F 3 are forces that must be accommodated in the design of the roof/wall connection. F 3 Figure 5 Bolted Top Plate Direct embedded roof truss anchor installed per manufacturers specifications 1 2 in. (13 mm) anchor bolt at 18 to 24 in. (457 to 610 mm) o.c., or as Roof truss at 24 in. (610 mm) o.c., max. Moisture barrier Horizontal reinforcement, Oversized washer per design, typ. Bond beam

Standard 90 hook with lap 4 in. (102 mm) min. Maintain minimum cover Reinforced cast-in-place or cut masonry rake beam at roof line 2 x 4 in. (38 x 89 mm) min. wood nailer with 1 2 in. (13 mm) anchor bolts Foundation at one-story building or bond beam at multistory 6a Continuous Gable End Wall Reinforcement 12 in. (305 mm) max. 8d nails at 6 in. (152 mm) o.c. 2 x 4 (38 x 89 mm) at 32 in. (813 mm) o.c., or Facia Soffit 2 (38 mm) x ladder framing at 24 in. (610 mm) o.c. max. 7 16 in. (11 mm) rated structural panels, 8d nails 6 in. ( 152 mm) o.c. at edges, 12 in. (305 mm) o.c. in field Oversized washer 2 x 6 (38 x 140 mm), pressure treated or use moisture barrier 8d nails at 6 in. (152 mm) o.c. 8 in. (203 mm) Bond beam 2 x 6 (38 x 140 mm) at 16 in. (406 mm) o.c. 1 1 Uplift strap, 100 lb. (0.44 kn) at each stud or per design Double 2 x 4 (38 x 89 mm) at 32 in. (813 mm) o.c. (1 each side of stud) or 5-8d nails each side or 5 8 in. (16 mm) diameter thru-bolt Uplift strap, 100 lb (0.44 kn) at each stud or 1 2 in. (13 mm) anchor bolt at 48 in. (1,219 mm) o.c. or proprietary anchor Mesh or other grout stop device Concrete masonry wall with vertical reinforcement as 5-8d nails each side or 5 8 in. (16 mm) diameter thru-bolt 2-8d toenails into brace 2 x 4 (38 x 89 mm) continuous nailed to truss webs (one per truss) Note: brace can be similarly used with a sloped beam at the top of a masonry end wall that terminates at the bottom of a vaulted ceiling (i.e., scissors truss) Joint in gable end wall 6b Braced Gable End Wall Figure 6 Gable End Wall Construction

Pressure treated 2 x 4 (38 x 89 mm) at 24 in. (610 mm) o.c., max. Roof sheathing Facia Soffit 24 in. (610 mm), max. overhang 90 standard hook Grout, as 8 in. (203 mm) Wood roof truss concrete rake beam with 1 No. 5 (M #16) bar min. (4 in. (102 mm) minimum depth) Concrete masonry wall Vertical wall reinforcement, Grout stop location 7a Section -, Concrete Rake Beam With Outlooker Type Overhang Facia Standard hook with lap, typ. 12 in. (305 mm) max. overhang Soffit 2 x 4 (38 x 89 mm) at 24 in. (610 mm) o.c. max. 2 x 4 (38 x 89 mm) (min.) pressure treated wood nailer 1 2 in. (13 mm) anchor bolt at 3 ft. (1,829 mm) o.c. max or per design Moisture barrier Cut concrete masonry units to match slope. Beam height varies, 4 in. (102 mm) min. Notch webs 2 3 4 in. (70 mm) for reinforcement Continuous reinforcement, 1 No. 5 (M #16) or Mesh or other grout stop device for cells not reinforced Concrete masonry wall Vertical reinforcement, Grout, Cut masonry rake beam 7b Section -, Cut Concrete Masonry Rake Beam With Ladder Type Overhang Figure 7 Gable End Wall Gable End Wall Overhangs Figure 7a shows a continuously reinforced cast-in-place concrete rake beam along the top of the gable end wall. The beam is formed over uncut block in courses successively shortened to match the slope of the roof. minimum of 4 in. (102 mm) is needed from the highest projected corner of block to the top of the beam. Reinforcement that is continuous with the bond beam reinforcement in the side walls is placed in the top of the beam. In this detail, an outlooker type overhang is shown where the rake beam is constructed 3 1 /2 in. (89 mm) lower than the trusses so that a pressure treated 2 x 4 (38 x 89 mm) can pass over it. ladder type overhang detail also can be used with the concrete rake beam where the beam is constructed to the same height as the trusses similar to that shown for the cut masonry rake beam in Figure 7b. Figure 7b shows a continuously reinforced cut masonry rake beam along the top of the gable end wall. Masonry units are cut to conform to the roof slope at the same height as the roof trusses. 2 3 /4 in. (70 mm) deep notch is cut into the tops of the concrete masonry webs to allow placement of reinforcement that is continuous with the bond beam reinforcement in the side walls. minimum of height of 4 in. (102 mm) is needed for the cut masonry bond beam. In this figure, a ladder type overhang is shown. However, an outlooker type overhang detail can be used similar to that shown for the cast-in-place concrete rake beam in Figure 7a.

REFERENCES 1. Building Code Requirements for Masonry Structures, CI 530-02/SCE 5-02/TMS 402-02. Reported by the Masonry Standards Joint Committee, 2002. 2. The Guide to Concrete Masonry Residential Construction in High Wind reas. Florida Concrete & Products ssociation, Inc., 1997. 3. Standard for Hurricane Resistant Residential Construction, SSTD 10-99. Southern Building Code Congress International, Inc., 1999. 4. 2000 International Building Code. International Code Council, 2000. 5. Steel Reinforcement for Concrete Masonry, TEK 12-4C. National Concrete Masonry ssociation, 2002. 6. nnotated Design and Construction Details for Concrete Masonry, TR 90B. National Concrete Masonry ssociation, 2003. 7. Design for Dry Single-Wythe Concrete Masonry Walls, TEK 19-2. National Concrete Masonry ssociation, 2002. 8. Flashing Strategies for Concrete Masonry Walls, TEK 19-4. National Concrete Masonry ssociation, 2003. 9. Flashing Details for Concrete Masonry Walls, TEK 19-5. National Concrete Masonry ssociation, 2003. 10.Minimum Design Loads for Buildings and Other Structures, SCE 7-02. merican Society of Civil Engineers, 2002. NTIONL CONCRETE MSONRY SSOCITION To order a complete TEK Manual or TEK Index, 13750 Sunrise Valley Drive, Herndon, Virginia 20171 contact NCM Publications (703) 713-1900 www.ncma.org