STRUCTURAL BUILDING COMPONENTS MAGAZINE January/February 2005

Similar documents
SECTION PLATE CONNECTED WOOD TRUSSES

Repair Techniques for Metal Plated Wood Trusses

1/31/2013. OWTFA - Metal Plate Connected Wood Trusses

TRAINING. To access the Truss Store go to any of the computers at the building materials desk and click on Vendor Catalogs = > Truss Store.

Common Errors in Truss Design

Truss Technology in Building:

INSTALLATION. General. Important Note. Design. Transport

TRUSS INDUSTRY STANDARD OF CARE ISSUES

POST AND FRAME STRUCTURES (Pole Barns)

STRUCTURAL ISSUES IN RESIDENTIAL CONSTRUCTION. Presented by: Susan L. Lasecki P.E., S.E.

ACCESSORY STRUCTURE Building permit information For 1 & 2-family dwellings

TYPICAL BEARING WALL FRAMING

INTRODUCTION. GANG-NAIL Truss System

FIGURE R502.2 FLOOR CONSTRUCTION

POST AND FRAME STRUCTURES (Pole Barns)

Steel Roof Trusses. An Overview on Designing, Manufacturing, and Installing Roof Trusses. Truss Types. Southline steel Industries i

Anchor bolts ASTM F1554, Gr. 36 Wide flange beams ASTM A992, Fy = 50 ksi Misc. structural steel ASTM A36, Fy = 36 ksi

Chapter 7. Roof Framing

Repair Techniques for Metal Plated Wood Trusses

SJI Updates Expanded Load Tables for Noncomposite Joists / Joist Girders and Development of New Composite Joist Series

Open-Web Trusses. Including Red-L, Red-W, Red-S, Red-M and Red-H Trusses. Design Flexibility. Outstanding Strength-to-Weight Performance

On Cold-Formed Steel Construction. Light Gauge Steel Engineers Association Washington, D.C Toll Free (866)

2) Open ConstructionCalc ProBeam from Microsoft Excel, then File Open. 3) Part 1 General Input.

POST FRAME BUILDING STANDARDS

LPI 56 Technical Guide

The only limit to the use of truss construction is one s imagination.

Compliments of American Truss Systems

130 MPH EXPOSURE B WFCM GUIDE. Guide to Wood Frame Construction in High Wind Areas for One- and Two-Family Dwellings 2015 EDITION

GARAGES/ONE-STORY City of Grand Rapids Building Safety Division

SCREEN PORCHES 101 DEVELOPMENT RESOURCES, INC Permit Requirements

Wood Truss Restraint and Bracing Guide

Hansen Pole Buildings Planning Guide. Toll Free / Toll Free FAX

City of Republic Community Development Girder and Header Spans for Exterior Walls

PS 3000 Installation Manual Step-By-Step Procedures C.9. DOOR AND WINDOW OPENINGS C.9.1 PREPARE IN ADVANCE. C.9.2 VBUCK CONSTRUCTION.

Truss Repair and Modifications. Overview Revised 4/7/2017

WFCM 130 MPH GUIDE EXPOSURE B WOOD FRAME CONSTRUCTION MANUAL GUIDE TO WOOD CONSTRUCTION IN HIGH WIND AREAS FOR ONE- AND TWO-FAMILY DWELLINGS

The following preliminary issues may need to be addressed prior to an application for a building permit.

RESPONSIBILITIES IN THE DESIGN PROCESS INVOLVING METAL PLATE CONNECTED WOOD TRUSSES

Residential Wood Deck Design

STATE UNIVERSITY CONSTRUCTION FUND. UNIVERSITY CON DIRECTIVE 5-1 Issue date: October 2014

CARROLL COUNTY BUREAU OF PERMITS AND INSPECTIONS RESIDENTIAL CODE COMPLIANCE GUIDELINES FOR DECKS

HILLSBOROUGH TOWNSHIP CODE ENFORCEMENT

LUMBER: USE IN CONSTRUCTION

June GANG-NAIL ROOF TRUSS SYSTEM (incorporating Attic Trusses) Residential Manual

2012 Wood Frame Construction Manual: Wind Load Distribution on Buildings Load Paths

What Should Constitute a Truss Submittal Package?

FACT SHEET #2 DECK INFORMATION

CHAPTER 5 FLOORS SECTION R501

Technical Data for. Headers. and Beams

LAMINATED VENEER LUMBER

Example Hot Tub Deck Design Using ConstructionCalc Software, v2.0

INSULATION RETROFIT DESIGN ENERGY SOLUTIONS CENTRE YUKON GOVERNMENT

Detailing For Wood Shrinkage

BROCHURE # 108 CONSTRUCTION PLAN COMPONENTS

CITY OF CEDAR FALLS DEPARTMENT OF DEVELOPMENTAL SERVICES INSPECTION SERVICES DIVISION PHONE Residential Accessory Structures

Raising Garage Trusses & Sheeting The Roof

Pole Barns. Guides For Homeowners. Why Do I need a Permit? DID YOU KNOW? Charles Abbott Associates. Tips on hiring contractors.

BARN MAIN FLOOR PLAN. #G457a 12 x 20 x 8 Gentleman Bunkhouse Shed By SDS-CAD Specialized Design Systems 12'-0" 3'-0" 4'-0" 1'-6" 3'-0" 1'-6" 20'-0"

Updated references to SEI/ASCE 7 to the 2016 edition once it is available.

EXCEL Medical Waste - Equipment Installation Section SECTION GYPSUM BOARD

LVL Product Guide 2.0E LVL 1.5E LVL

CONTENTS. Using Advanced CAD to Create 2D and 3D Objects in Chief Architect 1. Introduction..2

Pole Barns. Why Do I need a Permit? D ID Y OU K N OW? What you need to apply for a building permit: Tips on hiring contractors.

COFS Mission. AISI Standards Hierarchy. North American Standards for Cold-Formed Steel Framing. Member versus System Design. Specification 10/21/2016

Temporary Construction Loads Over I-Joist Roofs And Floors

RB104-09/10 R602.7, R (New), Table R (New), Figures R (1)-(2) (New)

MAX-CORE I-JOIST DESIGN MANUAL-US

Wood Roof Truss Systems. Submission Review & Inspection

SECTION NON-STRUCTURAL METAL FRAMING

HIGHLANDVIEW CEMETERY CHAPEL

2.2E Parallam PSL Deep Beam

RESIDENTIAL WOOD DECK CONSTRUCTION GUIDE

Colorado Chapter of the International Conference of Building Officials. Building Guide. The Colorado Chapter of the International

O PEN J OIST Installation Guide

Title: Building Construction for the Fire Service. Time: 3 hours. Teaching Materials: White board Building Construction for the Fire Service (PDF)

Heel Blocking Requirements and Capacity Analysis. Overview Revised 3/22/2017

CHAPTER 6 TYPES OF CONSTRUCTION

10 EXTREME BASEMENT PANELS

RESIDENTIAL CONSTRUCTION New Dwellings and Additions

SIPs over a steel frame Raised SIP floor

Calculated Quantities and Details

Administrative Changes

CHAPTER 3 BUILDINGS WITH WOOD FRAMED EXTERIOR WALLS 301 SCOPE

BUILDING TRADES II ALTERNATIVE FRAMING TECHNIQUES TEACHER S GUIDE

There are countless ways to improve constructability on your next project. Here are 50 of them. the need for it or specify it on the design drawings.

buildings. design of post-frame gyms and multipurpose

MAT109: Introduction to the Wood Frame Construction Manual

Residential Detached Garage Handout

Modular Wood Framing Goes Vertical

2) Open ConstructionCalc ProBeam from Microsoft Excel: File Open. 3) Part 1 General Input. Here is a screenshot of Part 1 input.

2.2E Parallam PSL Deep Beam

WASHINGTON STATE ENERGY CODE, APPENDIX CHAPTERS

PENNSAFE BUILDING INSPECTION SERVICES LLC Deck and Roof Cross Section Submittal

RESIDENTIAL DETACHED GARAGE HANDOUT

Individual Truss Marking Is it a Building Code Requirement?

Structural Comparison between Pan Joist Concrete and Steel Frame Systems for UMCP Student Housing Building B

PENNSAFE BUILDING INSPECTION SERVICES LLC PERMIT APPLICATION

What Should Constitute a Truss Submittal Package?

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: STRUCTURAL PANELS REPORT HOLDER: ENERCEPT, INC.

2003 International Residential Building Code

Transcription:

STRUCTURAL BUILDING COMPONENTS MAGAZINE January/February 2005 Knowledge Is Power Rules of Good Truss Design by Rachel Smith Design is the art of gradually applying constraints until only one solution remains. Unknown Truss technicians have highly specialized truss design software that allows them to design trusses to fit even the most complicated structural framing plans. One thing every good truss technician knows is that the simplest solution for them may not be the best solution for the folks who have to manufacture or install the trusses. I contacted several engineers from truss manufacturing operations all over the country and asked them to list some of the rules of good design they ask their technicians to follow. The list is by no means comprehensive, but it certainly will give every truss technician some food for thought. RULES FOR SYMMETRY If the outside geometry is symmetrical, make the webs, plates and splices symmetrical also. If some trusses have interior bearing and others do not, or if some trusses have overhangs and others do not, run both conditions and design one truss to fit both conditions. This can be done often with little or no extra cost. Keeping it simple makes the shop and the framer happy by reducing the number of pieces in the shop and truss types in the field. RULES FOR GIRDERS & HANGERS Optimize roof girder trusses by increasing plies and decreasing webs. This can also take care of some bearing length issues. Depending on the company s pricing structure, girders with more plies and fewer webs decrease board footage and metal plate connector size. Another option is to increase bottom chord lumber size and reduce the number of webs, although this may not help bearing length issues. Try designing floor girder trusses with double chords before resorting to a two-ply floor girder because it can be difficult to implement an effective connection of two-ply members in the 4x orientation. When a girder carries another girder, make sure there is a large vertical web installed in the carrying truss capable of accepting a large hanger. Also consider building girder trusses symmetrically to avoid backward installations.

Avoid girders that are four plies or more if at all possible. No one likes to deal with the bolts and that includes the shop, the framers and the truss design engineer. Shorten truss members framing into a beam by 1/4" for each hanger location, that is, 1/4" per end for a total of 1/2" if framing is between two beams. Consider the following for floors, roofs and girders: Shorten the span of floor trusses by 1/4" when framing into beams or girders and a hanger is used as the connection. This allows beam thickness variation and still maintains a 1-1/2" truss bearing length when the hanger seat is 1-3/4" (Simpson THA422 or USP MSH422 for example). Top chord bearing floor trusses allow a maximum 1/2" gap, therefore the 1/4" provides some tolerance for the truss to slide into position. Shorten the span of roof trusses by 1/4" when framing into a girder. This allows for the hanger gauge thickness and accounts for the fact that multi-ply girders are always somewhat thicker because of the metal plates. If the truss is stubbed, contains a raised heel, is a mono or mono-style jack, then recess the end vertical by 1/2" to 1" to allow for the span to be trimmed to fit. This helps ensure the vertical is not ripped. An exception is that if the hanger height is such that fasteners are required to penetrate the wood for uplift resistance, the end vertical probably cannot be FIGURE 1. FIGURE 2.

recessed. For girder-to-girder truss connections, the amount to shorten the truss is a function of the hanger steel thickness, type of connection, and the number of plies of the supporting girder truss. The worst case is a bolted hanger which may be three gauge (1/4"). Consider shortening the truss 3/8" to 1/2" for this condition to account for the varying thickness of the supporting girder. We recommend you check first with your hanger manufacturer on shortening trusses supported by hangers. According to ASTM D1761 Standard Test Methods for Mechanical Fasteners in Wood the gap between the joist and header shall not exceed 1/8". The listed hanger capacity may be affected if the gap is greater than 1/8". FIGURE 2. The next consideration is FIGURE 2. hangers that are attached with bolts recess end verticals (if there is a raised heel) from 1" to 1-1/2" to accommodate the bolt head (see Figure 1). RULES FOR DEFLECTION & SPAN-TO-DEPTH RATIOS Keep all span-to-depth ratios in floor framing to 20 or under. Therefore, attic frame trusses with a 2x10 bottom chord would be limited to a 16' wide room. Keep span-to-depth ratios in roof trusses to around 25. This is critical in tray ceiling locations where local deflections may exceed code allowed ratios. Understand where differential deflection will create problems and know how to address it. (See Technical Q&A) One suggestion was that total load deflection should be limited to 0.25 in between adjacent roof trusses with gypsum board ceilings.

Always consider shortening the span of scissor trusses framed between two girders to account for the horizontal deflection as load is applied to the trusses. RULES FOR CHORDS & WEBS When stubbing roof or floor trusses, maintain the same web pattern as the full profile truss in order for any web bracing to run through continuously. Hold-up bottom chords of cap or piggyback trusses by 1-3/4" for the top chord continuous lateral braces of the base truss. The additional 1/4" allows for variations in lumber thickness. See if the on-center spacing of the top chord bracing can be increased from 24" (see Figure 2). Increase the web size before requiring another row of lateral bracing. Have you ever seen a truss design with 2x3 webs and two rows of continuous lateral braces? Don t be that designer. Drop top chords to allow continuous 4x2 purlins along the end slope of step-down hip trusses to eliminate the need for the contractor to have to cut blocks. Alternatively, design and provide an end-slope gable lay-in truss. For truss spans over 45', investigate the economy of bumping up to a 2x6 top or bottom chord. The design may allow wider panels and fewer webs which typically means less board footage. If you bump up the top chord, remember that the heel heights for all trusses in the entire project may need to change. Miter top chord breaks that are over 8/12 in slope typically reduce plate size (see Figure 3). Use non-structural fillers in lieu of structural members for partial vaults, small flat ceiling sections in scissor-type trusses, or at tray ceilings. This allows site modifications to the profile without interfering with the structural design (see Figure 4). Non-structural trusses with tall heels on both ends should have at least one diagonal web to keep truss square and prevent racking. Automatic web placement speeds up the design, but it can cause inefficient lumber use. An hour of extra design time can save hundreds of dollars in the shop and make your sales people and customers happier as well. RULES FOR SPLICES Keep splice locations consistent through similar truss profiles. For step down hip trusses, keep the same bottom chord splice locations and splice top chords using the overhang end as the measurement start point to maintain similar splices. Don t splice top chords in the panel next to the heel joint. Don t splice in the center of an attic room.

Don t splice within the half panel next to a pitch break. Don t allow more than one splice within an attic room. Don t splice the sloping section of an attic top chord within the room area. Locate panel splices within one quarter of the panel length (+/- 12") from the joint on 2x trusses. Don t allow top and bottom chord splices to line up; they should be spaced at least a half panel apart. RULES FOR LOADS Understanding loads and how to apply them is an epic topic that is being addressed by a current WTCA project called Guide to Good Practice for Loading Metal Plate Connected Wood Trusses. Please check www.woodtruss.com for its availability. KNOW THY CUSTOMER Think like a framer. Get out to jobsites and talk to framers about what they want. Framerfriendly design may add a little cost to the package, but they will be demanding your trusses from the decision-makers. Check out what your competition is doing. You can learn a lot from them. Have an up-to-date design policy and customer preferences/requirements manual. Don t assume anything. If there is any uncertainty, ask and get it in writing. Make sure the person you are talking to has the authority to give the answer. If you want to make changes, get approval in writing. Write down anything anyone tells you about the job with source and date including internal sources. Why is there never enough time to do the job right the first time, but always time to do it over? Avoid the rush job. If you know far enough ahead it will be a rush, price it to make it worth your while and cover the inevitable problems. Refuse to be rushed into not getting all the answers you need. The customer will be more angry when it s wrong. RULES FOR ESTIMATING & JOBS Don t sweat the details on bids. For example, overall dimensions are off by an inch, is the 12" overhang gross or net, what is the exact location of a plumbing trap, etc. You will waste your time if you don t get the job and you won t get them all. Understand the things that have a big effect on a bid price and must be correct. For example, big dead loads: is the snow load specified as ground snow or roof snow, non-standard heel heights, specs for 2x6 chords, or required minimum lumber values? Check for first floor planes getting into second floor windows. Check for heel heights that cause fascia and frieze boards to interfere with window and door openings. Just because it looks fine in the plans doesn t make the drawing a reality.

When you finish a job, step away from it a while, and then double check it. Most importantly, know when to break the rules. In order to pull this off, you have to know the purpose of the rule and have the experience to recognize when the rule is hurting the larger goals of economy, efficiency and quality. Thanks to these truss engineers who shared their design expertise with us: Scott Coffman in South Carolina, Joe Heinsman in Indiana, Steve Kennedy in Iowa, Joe Michels in Wisconsin, Stan Koehlinger in Ohio and Ian Richards in Ontario. SBC HOME PAGE Copyright 2005 by Truss Publications, Inc. All rights reserved. For permission to reprint materials from SBC Magazine, call 608/310-6706 or email editor@sbcmag.info. The mission of Structural Building Components Magazine (SBC) is to increase the knowledge of and to promote the common interests of those engaged in manufacturing and distributing of structural building components to ensure growth and continuity, and to be the information conduit by staying abreast of leading-edge issues. SBC will take a leadership role on behalf of the component industry in disseminating technical and marketplace information, and will maintain advisory committees consisting of the most knowledgeable professionals in the industry. The opinions expressed in SBC are those of the authors and those quoted solely, and are not necessarily the opinions of any of the affiliated associations (SBCC, WTCA, SCDA & STCA).