REScheck Compliance Certificate Massachusetts Energy Code REScheck Software Version 3.6 Release 1 Data filename: O:\REScheck 38\38258.

Similar documents
Compliance Certificate

Plan Check & Field Inspection Guide

1998 and 2000 International Energy Conservation Code Version 3.0 April 2000

Hardin County Planning and Development Commission

New Hampshire Residential Energy Code

Fenestration Components: Mechanical Summary. Water heater energy factor: Ef Fuel type: Gas Electric Other

Boulder City NV Prepared by (Print Name) Signature Date

2015 Michigan Residential Code Energy Worksheet for New Single-family Residential Building

A Closer Look Inspection Service 2015 IECC Residential DFW area handout

Instructions for the Residential Building Data Collection Checklist 2009 International Energy Conservation Code with 2011 Georgia Amendments

Date Rater Verified. Rater Verified. Slab / Pre-Drywall / Thermal Inspection

Single Family Residence Building Permits

Feature Zone IECC 2009 IECC

Interpretation Variables and Common Areas of Confusion. Of the 2009 IECC

CHAPTER 1: OVERVIEW OF ENERGY EFFICIENT CONSTRUCTION

APPROVED. Acceptable to the code official for compliance with the provisions of the applicable Code or referenced Standard.

Prescriptive Checklist for the 2015 Washington State Energy Code

Michigan Energy Code Training and Implementation Program

THE GEORGIA ENERGY CODE: 2009 IECC + AMENDMENTS

RESIDENTIAL ENERGY EFFICIENCY

RESIDENTIAL ENERGY EFFICIENCY

Questar ThermWise Duct Technical Specifications

BUILDING ENERGY CODES UNIVERSITY

A LOOK INTO THE 2015 IECC RESIDENTIAL PROVISIONS. Presented by: Shaunna Mozingo, Colorado Code Consulting

SAN MIGUEL COUNTY & TOWN OF MOUNTAIN VILLAGE BUILDING DEPARTMENTS PRESCRIPTIVE ENERGY CODE & GREEN BUILDING STANDARD

Montana Homebuilder Brief: Residential Energy Code 1

IECC 2015 with Hawaii Amendments COMMERCIAL DESIGN CHECKLIST

Michigan Energy Code Training and Implementation Program

2012 IECC Residential with State Adopted Changes

Recommended Amendments to the 2012 International Residential Code (IRC)

CERTIFICATE OF FIELD VERIFICATION & DIAGNOSTIC TESTING (Page 1 of 8)

Subject: Energy Subcode Compliance. Reference: N.J.A.C. 5: (f)1.vi, 2.18(b) and 3.18

Energy Code Basics for Residential Buildings. Presented by Newport Ventures NEWPORT VENTURES

IECC Commercial Significant Changes Summary Tier I

Inspection of New One- and Two- Family Dwellings

Module number 6 provides an on-line, self-paced training seminar on energy efficiency and energy conservation for residential buildings.

Only required in new home construction

Vermont Residential Building Energy Code. Handbook. A Guide to Complying with Vermont s Residential Building Energy Standards (30 V.S.A.

Energy Efficiency Programs

Insulation, Fireblocking, Draftstopping and Crawl Space Requirements REVISION DATE: JANUARY 2017

Oregon High Performance Home Requirements

If you are choosing a limited glazing area prescriptive option, completing the Glazing Schedule will be the first task.

CHAPTER 11 ENERGY EFFICIENCY

RESIDENTIAL ENERGY CHAPTER 4

2010 National Building Code Adoption and Associated Process Changes

Low-cost Construction for High-energy Savings. Brian J. Wimmer Construction Manager Rochester Area Habitat for Humanity

10 Steps to Save Energy in Your House

2015 IECC Residential Basic Principles Updates with State Amendments

IRC 2012 Key Changes

Part IV Energy Conservation

Village of Glen Ellyn Basement Remodeling Project Guidelines

Chapter 2: Foundation

Manitoba Energy Code for Buildings. Part 3 Building Envelope

INSIDE RESCheck / COMCheck

Chapter Above code programs. Deleted. Chapter 2

The Energy Audit National Weatherization Training Conference Priority Lists Experiences and Impacts Nick Milano

Energy Efficiency: Designing Wood-Frame Buildings for Occupant Comfort

Training Certification Categories

Is Yours? Homes Across Missouri are Being Built to the Latest National Energy Efficiency Standards

Chapter 1: Compliance

Green Remodeling Illustrations GREEN REMODELING ILLUSTRATIONS GREEN BUILDING GUIDELINES FOR HOME REMODELING

Design & Construction Standards, Revised January

A. GENERAL INFORMATION

Vermont Residential Building Energy Code. Handbook

2018 WEATHERIZATION SPECIFICATIONS MANUAL

NCAT. Energy Code Evolution

Lock In Energy Savings For Life

General Residential Code Requirements

ENERGY EFFICIENCY CERTIFICATION

fort collins building & zoning

Crawl Space Moisture Control

PREP + INSULATION. DISCLAIMER: These tools are for illustrative purposes only and

1) For the purpose of this Section, the term common space shall mean all spaces required to

Construction Report NYSERDA Residential Performance Challenge

2006 INTERNATIONAL ENERGY CONSERVATION CODE

This page has been left blank intentionally.

1. When using the REScheck software, the compliance report submitted by the permit holder shall indicate that the applicable code is.

One and Two Family Additions

BASEMENT FINISH PERMIT AND BUILDING CODE REQUIREMENTS (REVISED 3/6/2018)

SPARTANBURG COUNTY BUILDING CODES DEPARTMENT

HCM UNIVERSITY OF ALASKA FAIRBANKS Building Challenges in Alaska UNIVERSITY OF ALASKA FAIRBANKS

2012 CLEAResult All rights reserved. Residential Energy Efficiency

City of High Point Airport Overlay District Noise Level Reduction Design Standards

5. AMCA 301 Method of Publishing Sound Ratings for Air Moving Devices. 6. AMCA 500 Test Methods for Louver, Dampers, and Shutters

Deliverable for task 1.2 Side by Side tests of HUD code Homes, September 27, Zero Energy Manufactured Home Project (ZEMH)

NEW HAMPSHIRE CODE OF ADMINISTRATIVE RULES

RESIDENTIAL 1 & 2 FAMILY PERMIT APPLICATION

ALASKA ENERGY BUILDING STANDARD EFFICIENCY

REQUIREMENTS FOR SUBSTANTIALLY DAMAGED AND SUBSTANTIALLY IMPROVED STRUCTURES

Florida HERO Program Residential Eligible Product List All Products

2011 NORTHERN NEVADA ENERGY CODE AMENDMENTS

Presentation Overview: NC Energy Code RESNET Standards HERS Index HERS Verification Process

Technical Bulletin. No. 21 : Insulating Basements and Crawl Spaces (Revised 7/04) hwinsulation CONTRACTORS ASSOCIATION OF AMERICA

ORDINANCE. APPROVED EMERGENCY: (Yes) (No) VETOED: Date

HVAC INSULATION. A. General Requirements for Flexible Elastomeric Insulation: 3. Use pre-molded roll on pipe sizes 3.5" and below.

Connecticut 2011 Baseline Study of Single-Family Residential New Construction. Final Report

Quick Reference Guide for 2009 IECC Residential Energy Efficiency Climate Zone 6

Attached Solar Greenhouse Plans for a solar heated greenhouse attached to your home

Building & Ductwork Airtightness Standards

WEB BASED APPLICATION SPECIFIC INSTALLATION INSTRUCTIONS

Transcription:

Permit Number REScheck Compliance Certificate Massachusetts Energy Code REScheck Software Version 3.6 Release 1 Data filename: O:\REScheck 38\38258.rck Checked By/Date PROJECT TITLE: All American / Whalen 3 CITY: New Bedford STATE: Massachusetts HDD: 5426 CONSTRUCTION TYPE: 1 or 2 Family, Detached HEATING SYSTEM TYPE: Other (Non-Electric Resistance) WINDOW / WALL RATIO: 0.14 DATE: 02/01/05 DATE OF PLANS: 2-1-05 PROJECT DESCRIPTION: Job Number: 38258 Prepared by: John Koehler DESIGNER/CONTRACTOR: Premier Builders, A Division of Muncy Homes, Inc. 1567 PA Route 442 East, P.O. Box 337 Muncy, PA 17756 PROJECT NOTES: 1- Calculations reflect only that portion of unit assembled in the factory. 2- Builders or contractors may supply and install the required floor and/or foundation wall insulation. 3- For basements remaining unconditioned spaces, the builder shall enclose the basement stairs. The walls surrounding the basement stairs shall be insulated and protected with a vapor barrier. The builder is responsible for supplying all materials. COMPLIANCE: Passes Maximum UA = 164 Your Home UA = 137 16.5% Better Than Code (UA) Gross Glazing Area or Cavity Cont. or Door Perimeter R-Value R-Value U-Factor UA Ceiling 1: Flat Ceiling or Scissor Truss 663 38.0 0.0 20 Wall 1: Wood Frame, 16" o.c. 827 19.0 0.0 40

Window: 34 x 49 W: Vinyl Frame, Double Pane with Low-E 116 0.330 38 Door: 36 x 80 Blank: Solid 42 0.200 8 Floor 1: All-Wood Joist/Truss, Over Unconditioned Space 663 19.0 0.0 31 COMPLIANCE STATEMENT: The proposed building design described here is consistent with the building plans, specifications, and other calculations submitted with the permit application. The proposed building has been designed to meet the Massachusetts Energy Code requirements in RES check Version 3.6 Release 1 (formerly MECcheck) and to comply with the mandatory requirements listed in the RES check Inspection Checklist. The heating load for this building, and the cooling load if appropriate, has been determined using the applicable Standard Design Conditions found in the Code. The HVAC equipment selected to heat or cool the building shall be no greater than 125% of the design load as specified in Sections 780CMR 1310 and J4.4. Builder/Designer Date

REScheck Inspection Checklist Massachusetts Energy Code REScheck Software Version 3.6 Release 1 DATE: 02/01/05 PROJECT TITLE: All American / Whalen 3 Bldg. Dept. Use Ceilings: [ ] 1. Ceiling 1: Flat Ceiling or Scissor Truss, R-38.0 cavity insulation Comments: Above-Grade Walls: [ ] 1. Wall 1: Wood Frame, 16" o.c., R-19.0 cavity insulation Comments: Windows: [ ] 1. Window: 34 x 49 W: Vinyl Frame, Double Pane with Low-E, U-factor: 0.330 For windows without labeled U-factors, describe features: # Panes Frame Type Thermal Break? [ ] Yes [ ] No Comments: Doors: [ ] 1. Door: 36 x 80 Blank: Solid, U-factor: 0.200 Comments: Floors: [ ] 1. Floor 1: All-Wood Joist/Truss, Over Unconditioned Space, R-19.0 cavity insulation Comments: Air Leakage: [ ] Joints, penetrations, and all other such openings in the building envelope that are sources of air leakage must be sealed. [ ] When installed in the building envelope, recessed lighting fixtures shall meet one of the following requirements: 1. Type IC rated, manufactured with no penetrations between the inside of the recessed fixture and ceiling cavity and sealed or gasketed to prevent air leakage into the unconditioned space. 2. Type IC rated, in accordance with Standard ASTM E 283, with no more than 2.0 cfm (0.944 L/s) air movement from the the conditioned space to the ceiling cavity. The lighting fixture shall have been tested at 75 PA or 1.57 lbs/ft2 pressure difference and shall be labeled. Vapor Retarder: [ ] Required on the warm-in-winter side of all non-vented framed ceilings, walls, and floors. Materials Identification: [ ] Materials and equipment must be identified so that compliance can be determined. [ ] Manufacturer manuals for all installed heating and cooling equipment and service water heating

equipment must be provided. [ ] Insulation R-values and glazing U-factors must be clearly marked on the building plans or specifications. Duct Insulation: [ ] Ducts shall be insulated per Table J4.4.7.1. Duct Construction: [ ] All accessible joints, seams, and connections of supply and return ductwork located outside conditioned space, including stud bays or joist cavities/spaces used to transport air, shall be sealed using mastic and fibrous backing tape installed according to the manufacturer's installation instructions. Mesh tape may be omitted where gaps are less than 1/8 inch. Duct tape is not permitted. [ ] The HVAC system must provide a means for balancing air and water systems. Temperature Controls: [ ] Thermostats are required for each separate HVAC system. A manual or automatic means to partially restrict or shut off the heating and/or cooling input to each zone or floor shall be provided. Heating and Cooling Equipment Sizing: [ ] Rated output capacity of the heating/cooling system is not greater than 125% of the design load as specified in Sections 780CMR 1310 and J4.4. Circulating Hot Water Systems: [ ] Insulate circulating hot water pipes to the levels in Table 1. Swimming Pools: [ ] All heated swimming pools must have an on/off heater switch and require a cover unless over 20% of the heating energy is from non-depletable sources. Pool pumps require a time clock. Heating and Cooling Piping Insulation: [ ] HVAC piping conveying fluids above 120 ºF or chilled fluids below 55 ºF must be insulated to the levels in Table 2.

Table 1: Minimum Insulation Thickness for Circulating Hot Water Pipes. Insulation Thickness in Inches by Pipe Sizes Heated Water Non-Circulating Runouts Circulating Mains and Runouts Temperature ( F) Up to 1" Up to 1.25" 1.5" to 2.0" Over 2" 170-180 0.5 1.0 1.5 2.0 140-160 0.5 0.5 1.0 1.5 100-130 0.5 0.5 0.5 1.0 Table 2: Minimum Insulation Thickness for HVAC Pipes. Fluid Temp. Insulation Thickness in Inches by Pipe Sizes Piping System Types Range ( F) 2" Runouts 1" and Less 1.25" to 2" 2.5" to 4" Heating Systems Low Pressure/Temperature 201-250 1.0 1.5 1.5 2.0 Low Temperature 120-200 0.5 1.0 1.0 1.5 Steam Condensate (for feed water) Any 1.0 1.0 1.5 2.0 Cooling Systems Chilled Water, Refrigerant, 40-55 0.5 0.5 0.75 1.0 and Brine Below 40 1.0 1.0 1.5 1.5 NOTES TO FIELD (Building Department Use Only)