Limited Use/Limited Application Elevator DESIGN GUIDE. ASME A17.1, Part V, Section 5.2. LU/LA Hydraulic Drive. symmetryelevator.com

Similar documents
ELVORON LU/LA ELEVATOR

Introduction. Disclaimer. Table of contents

Beautifully Crafted, Expertly Engineered, Thoughtfully Constructed

SPECIFICATIONS. Part 1- General

Residential Elevator Design Guide

V1504 VERTICAL PLATFORM LIFT PLANNING GUIDE

VPL-3200B Residential Vertical Platform Lift Technical Specifications

SECTION HYDRAULIC DRIVE MACHINE ROOM (MR) RESIDENTIAL ELEVATORS

2. Cab, interior finishes, control panel and facings including cab doors. 3. Fire rated hoistway doors, sills, and frames.

Union County Vocational - Technical Schools Scotch Plains, New Jersey

Planning Guide (Imperial)

PART 2. PRODUCTS 2.01 Traction Elevators A. Traction elevators shall be Hollister - Whitney Elevator Company equipment.

SECTION INCLINE WHEELCHAIR LIFT PART 1 GENERAL 1.1 SECTION INCLUDES. A. Stair wheel chair lift. 1.2 RELATED SECTIONS

SECTION SECTIONAL OVERHEAD DOORS 522 SERIES ALUMINUM SECTIONAL OVERHEAD DOORS. Display hidden notes to specifier. (Don't know how?

UNIVERSITY OF ALASKA FAIRBANKS DIVISION 14 - CONVEYING EQUIPMENT DESIGN STANDARDS SECTION

ELEVATORS, LULAS AND PLATFORM LIFTS

Accessibility, Safety & Platform Lifts and Elevators v2

Savaria Eclipse Home Elevator

SECTION LAGUNA SERIES TOP HUNG SLIDING DOOR SYSTEM

Elevating your standard of living

ANSI/ ASME HST Performance Standard For Overhead Electric Wire Rope Hoists

Freight Elevator Series GFM-T

1. Vertical reciprocating conveyor, Hydraulic straddle VRC.

LTH3700, HOLLOW METAL SLIDING FIRE DOOR

Training Certification Categories

SECTION SECTIONAL OVERHEAD DOORS

LIFT APPLICATION GUIDELINES ACCESSTAIR MODEL VMH-08

UNIFIED FACILITIES CRITERIA (UFC) ELEVATORS

SECTION ENTRANCE FLOOR GRILLES STAINLESS STEEL GRATING

You dream it. We build it. ELEVATORS

SECTION OVERHEAD COILING FIRE DOORS MODEL 662 OVERHEAD COILING COUNTER FIRE DOORS WITH INTEGRAL FRAME

Revision 1 RAM ELEVATORS. Elevator Electrical Planning Guide. RAM Manufacturing Ltd

Telecommunication Spaces

Model 5200 Cargo Lift Installation and Operation Manual

3M Intelligent Return Plus and Sorter System SL. Architect/Contractor's Package

SECTION [ ] COILING COUNTER DOORS. Display hidden notes to specifier. (Don't know how? Click Here)

FABRICOIL BASIC January 10, 2006

Page 1 PRODUCT DESCRIPTION SECTION SECTIONAL OVERHEAD DOORS MODEL 900 PRODUCT FEATURES

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017

ELEVATORS & SERVICE LIFTS FREIGHT HOIST MAST LIFTS FREIGHT HOIST SCISSOR LIFTS ELEVATING DOCK SCISSOR LIFTS DOCK LEVELLERS

Model 5200 Cargo Lift Installation and Operation Manual

800 Series Aluminum Overhead Doors, by Northwest Door Section ALUMINUM SECTIONAL DOORS Digicon Information Inc.

Riser and Tread Dimensions Riser Tread inches (mm) inches (mm)

Series - 1

A/E Design Deliverable Checklist

HIGH MAST CAMERA POLE ASSEMBLY GENERAL

N-SERIES: NTH3500 SPECIFICATIONS Hollow Metal Sliding Door System

Westgate Entrematic, Parking Security Gates Section OVERHEAD SECURITY GATE Prepared by: Digicon Information Inc. Page 1

Model 5000 Cargo Lift Installation and Operations Manual

Therma Series Insulated Overhead Doors, by Northwest Door Section SECTIONAL DOORS Digicon Information Inc.

CONTRACT DOCUMENTS REVIEW PACKAGE CHECKLIST

June 2017 Draft for Public Review. A X, Safety Code for Elevators and Escalators (Proposed Revisions of ASME A17.

V1504 Planning Guide Dec. 2006

This guide can be used to prepare a specification for incorporating free standing jib cranes into a competitively bid construction project.

A. This Section includes automatic entrance door systems operating as follows: 1. Swinging operation.

REQUIREMENTS FOR INDOOR INSTALLATION OF PADMOUNTED TRANSFORMERS

FoldingAccess Series Aluminum Folding Door System

Machine-roomless holeless hydraulic elevator

Specifications for Residential Overhead Electric Service Installation

Standard program overview fire doors

Series Sump and Sewage Systems

SECTION VIBRATION AND SEISMIC CONTROL FOR PLUMBING

UNDERGROUND SERVICES (RESIDENTIAL) SINGLE FAMILY RESIDENTIAL, DUPLEXES, OR TOWNHOUSES

Electric Service Standards

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017

Repair or replace section of driveway, approach, or sidewalk that are a trip hazard.

On-Call General Contractor Specifications University of Maryland College Park June 2013

Section SECTIONAL INSULATED STEEL DOORS

1. American Architectural Manufacturers Association (AAMA): 2. American Society of Mechanical Engineers (ASME):

Series - 1

1. Florida Building Code (FBC), with special attention to the following:

FAIRBANKS NIJHUIS SUBMERSIBLE SOLIDS HANDLING PUMPS.

This guide can be used to prepare a specification for incorporating free standing jib cranes into a competitively bid construction project.

2. Water Pressure Booster Systems. 3. Duplex Pedestal Type Sump Pumps.

A/E Design Deliverable Checklist

SECTION HEAVY GLASS TOP HUNG SLIDING BI-FOLD DOOR SYSTEMS

SECTION HYDRAULIC ELEVATORS

SECTION CRL50 AND CRL51 HEAVY GLASS TOP HUNG SLIDING DOOR SYSTEMS

SECTION Manufactured Metal Casework FLEXIBLE LABORATORY FURNITURE SYSTEM (OPTIMA) USA VERSION

Please check with your local inspection authority for any additional requirements before installation.

HD-Swing Series 4000 Heavy Duty Aluminum Swing Door System with Electric Operator

A. AMERICAN ARCHITECTURAL MANUFACTURERS ASSOCIATION (AAMA) 101: Appendix Dissimilar Materials.

SECTION ACTIVE VEHICLE BARRIERS

CONSTRUCTION REQUIREMENTS

SECTION TRACTION ELEVATORS

C. Section Metal Fabrications: Steel frame and supports.

Aluminum-Framed Entrances and Storefronts

MINIMUM SPECIFICATIONS

SECTION PACKAGE BOOSTER PUMP STATIONS

SECTION ALUMINUM GATES

Data Sheet Wöhr Combilift 552-2,6

MODERNFOLD GWS 100SR-G MOVEABLE GLASS WALLS

DIVISION 14 CONVEYING SYSTEMS

HD-Slide Series 2001 Heavy Duty Aluminum Sliding Door System with Electric Belt Drive Operator

MIAMI UNIVERSITY PHYSICAL FACILITIES DEPARTMENT BACHELOR HALL ELEVATOR RENOVATION TABLE OF CONTENTS TABLE OF CONTENTS... TOC-1-2

Residential Elevators

FOUR FOLD DOORS-WITH SINGLE OVERHEAD MTD OPERATOR

1 AND 2 FAMILY DWELLING REQUIREMENTS

DIVISION MEDIUM VOLTAGE VAULT DESIGN Contents MEDIUM VOLTAGE VAULT DESIGN... 2 DIVISION LIST OF FIGURES...

Design Guidelines Technology

Transcription:

Limited Use/Limited Application Elevator DESIGN GUIDE ASME A17.1, Part V, Section 5.2 LU/LA Hydraulic Drive symmetryelevator.com 877.375.1428

Table of Contents Elevation Limited Use/Limited Application Elevator... 3 Roped Hydraulic Drive Component Identification... 4 Common Specifications for LU/LA Elevator Equipment... 5 Hoistway Configurations Limited Use/Limited Application Elevator... 6 Left-Hand Entrance Frame... 7 Right-Hand Entrance Frame... 8 Machine Room for Hydraulic Drive Standard & Compact... 9 Hoistway Typical Rail Backing Construction and Construction Outline... 10-11 Hoistway Single Opening... 12 Hoistway Opposite Opening... 13 Hoistway 90 Degree Opening... 14 Notes... 15 About Symmetry Elevating Solutions Symmetry is a beautifully crafted, expertly engineered accessibility-related product line proudly made in the U.S.A. at the Bella Elevator LLC manufacturing plant. Promoted and sold by our exclusive nationwide network of carefully selected Symmetry partners and associates, Symmetry offers residential elevators, vertical platform lifts and Limited Use/Limited Application (LU/LA) elevators. Strictly following national code guidelines and adhering to local jurisdiction requirements and variances, Symmetry products are ADA and ASME compliant and manufactured to meet the end users specific needs. Symmetry Elevating Solutions representatives possess a wealth of knowledge and experience and are committed to excellence for the life of the product before, during and after project completion. With dealer locations spanning North America, we are equipped to meet the accessibility needs of a wide spectrum of clients, from home and business owners, to schools, municipalities and other governmental entities. Please note that this guide is for planning purposes only, applies exclusively to national code and should not be used for construction. Prior to construction, please contact your local Symmetry Elevating Solutions representative and request a job-specific set of elevator plans to ensure that you obtain the accurate dimensions and requirements for your project. Your representative will also assist you to identify resources to ensure that your project plans will comply with the applicable state and local codes and the permitting authorities. 2 symmetryelevator.com 877.375.1428

Elevation Limited Use/Limited Application Elevator What is a Limited Use/Limited Application Elevator? The LU/LA elevator is designed to meet the requirements of the Americans with Disabilities Act (ADA) and to provide access for low occupancy/low rise commercial buildings where a traditional passenger elevator is not feasible or required by code. When only the highest level of safety is your standard, the Elevation LU/LA elevator is the optimal product for your project. Leading the industry in quality, style and design, Elevation by Symmetry is engineered and designed for limited commercial, as well as residential, use. The Elevation is ideal for applications up to six stops and up to 50 feet of travel (with travel variance) and is designed for use in schools (and other educational settings), churches, multi-family housing units, libraries and more. Symmetry LU/LA elevators are available with: Shallowest pit depth required in the industry 13" pit with elastomeric bumpers (ASME A17.1 year 2013 & prior) 14" pit with buffer springs (ASME A17.1 year 2016) Shortest overhead required in the industry for existing buildings 106" with alternate means All light sources are powered by energy-efficient LED technology Including car operating panel (COP), car lights and directional indicators symmetryelevator.com 877.375.1428 3

Roped Hydraulic Drive Component Identification Ram's Header 8 lb. T-Rail Rail Bracket Hydraulic Cylinder Car Frame ⅜" 7 x 19 Galvanized Aircraft Cable Pedestal Post Controller Pedestal Base Power Unit 4 symmetryelevator.com 877.375.1428

Common Specifications for LU/LA elevator equipment Standard Features Automatic self-leveling 2:1 roped hydraulic drive system Smooth start and stop Two-stop operation 36"-wide doors, automatic horizontally sliding, two speed hoistway and car door; full-height light curtain Pit depth: - ASME A17.1 year 2013 & prior standard 13" with elastomeric bumpers and alternative means (bottom car clearance device) - ASME A17.1 year 2016 standard 14" with buffer springs and alternative means (bottom car clearance device) Overhead: 11'0" standard or 8'10" (106") with alternative means (top car clearance device) Selective Collective Programmable Logic Controller (PLC) Car-mounted directional indicator with audible signals 4 hp submersible pump and motor for quiet operation Two-speed control valve Low oil protection Single-stage hydraulic jack and two ⅜" aircraft cables using wedge sockets 8 lb. T-rail Heavy-duty rollers and guides 7'0" standard car height Homing timer Digital position indicator ADA hands-free phone Passing chime Optional Features Up to six stops Custom wood cars Stainless steel cars Laminate applied car panels Overspeed governor Speed: 40 fpm with variance 50'0" travel with variance and derated capacity Three-phase motor & controller (208/230 VAC; 3 ph, 20 amp, 5 hp) Buffer springs (minimum 14" pit required) Landing position indicator Hoistway access Phase 1 and Phase 2 fire service Phone line monitoring system Green drive system by adding environmentally friendly hydraulic oil Safety Features Keyed in-car stop switch and alarm button Emergency lighting in car interior Uninterruptible Power Supply (UPS) for car lowering and operation of car and hoistway doors in the event of a power failure Emergency manual lowering Slack/broken cable safety brake device Overspeed valve ETL, UL or CSA certified components Tactile/braille characters Elastomeric bumpers (ASME A17.1 year 2013 & prior) or buffer springs (ASME A17.1 year 2016) Platform Sizes 48"W x 54"D standard 42"W x 54"D standard 42"W x 60"D optional 51"W x 51"D 90 optional Specifications Power supply: 208/230 VAC, 1 ph, 30 amp, 60 hz Capacity: 1400 lb. (635 kg) Speed: 30 fpm (.15 m/s) Travel: up to 25'0" standard Three-year limited parts warranty Standard Warranty Provides a three-year limited warranty covering replacement of defective parts and excluding labor.* * Preventative maintenance agreement required. Symmetry LU/LA elevators are designed to comply with ASME A17.1 Section 5.2 and the Americans with Disabilities Act (ADA). All LU/LA elevators are limited by speed, travel and capacity in order to comply with applicable code. Please note that this guide is for planning purposes only, applies exclusively to national code and should not be used for construction. Prior to construction, please contact your local Symmetry Elevating Solutions representative and request a job-specific set of elevator plans to ensure that you obtain the accurate dimensions and requirements for your project. Your representative will also assist you to identify resources to ensure that your project plans will comply with the applicable state and local codes and the permitting authorities. symmetryelevator.com 877.375.1428 5

Hoistway Configuration Limited Use/Limited Application Elevator Notes: 1) Hoistway must be free of any obstructions unrelated to the elevator operation (i.e. pipes, ducts, etc.). Refuge Space 43" Minimum 2) The minimum floor-to-floor travel between any two entrances on the same wall is 98½ inches (8'2½"). 3) The minimum floor-to-floor travel between any two landings is 16 inches. 4) The minimum pit depth is 13 inches (14 inches if buffer springs are required). Overhead 80" Clear Opening 3" Overtravel 80" Clear Opening 5) The minimum overhead is 9'6" for existing construction or 11'0" for new construction. Work by General Contractor: A) Pit Light Switch installed 4'0" above the lower finished floor B) Pit G.F.I. Duplex Receptacle C) Pit Light Floor to Floor Pit Depth 80" Clear Opening 2" Minimum Undertravel 80" Clear Opening Overall Hoistway A B C 6 symmetryelevator.com 877.375.1428

Left-Hand Entrance Frame 54" Minimum Rough Opening 40" Overall Frame Width 36" Clear Opening Notes: 1) Hoistway entrances are manufactured in accordance with 1½ hour fire-rated construction. 2) Hoistway walls to have a fire endurance rating not less than required by Section 110 (1996) or Section 2.1 (2000+) ASME A17.1 Elevator Safety Code. 9¾" 42" Hall Call Centerline 2¾" 60" Centerline for Jamb Braille Door C/L (from Hoistway Overview Drawing) Door Slides to Open Door Slides to Open 80" Clear Opening 82" Overall Frame Height 92" Minimum Rough Opening 3) Furnishing, installing and maintaining the required fire rating of elevator hoistway walls, including the penetration of the fire wall by elevator fixture boxes, is not the responsibility of the elevator contractor or manufacturer. 4) The interface of the hoistway wall with the hoistway entrance shall be in strict compliance with the entrance manufacturer's requirements in order to retain fire rating and label validity of the elevator hoistway doors and frame. 5) Hoistway walls at entrances should be left open for the full width of the shaft until after door sills and frames are set in place. If this is not feasible, leave a 54"W x 92"H rough opening. 6) Filling and grouting by General Contractor. 25½" Minimum Strike Side Rough Opening 28½" Minimum Return Side Rough Opening Double ⅜" Sheetrock Minimum Double 2 x 10 Header 1" Sheetrock 6" Typical Hoistway Sill Line 2" 1" Sheetrock Double ⅜" Sheetrock Masonry Construction Sill Anchors: (6) ⅜" x 3" Wedge Concrete Anchors Wood/Drywall Construction Sill Anchors: (6) ⅜" x 4" Lag Bolts, Zinc Finished Flooring 6" ¾" Finished Flooring 6" 4⅞" 8⅛" 4⅞" 92" Above Finished Floor 8⅛" ¾" 2½" 2½" Concrete Slab Hoistway Sill Line Two 2 x 10s Behind Sheetrock Hoistway Sill Line symmetryelevator.com 877.375.1428 7

Right-Hand Entrance Frame 54" Minimum Rough Opening 40" Overall Frame Width 36" Clear Opening Notes: 1) Hoistway entrances are manufactured in accordance with 1½ hour fire-rated construction. 2) Hoistway walls to have a fire endurance rating not less than required by Section 110 (1996) or Section 2.1 (2000+) ASME A17.1 Elevator Safety Code. 92" Minimum Rough Opening 82" Overall Frame Height 80" Clear Opening Door C/L (from Hoistway Overview Drawing) Door Slides to Open Door Slides to Open 60" Centerline for Jamb Braille 9¾" 2¾" 42" Hall Call Centerline 3) Furnishing, installing and maintaining the required fire rating of elevator hoistway walls, including the penetration of the fire wall by elevator fixture boxes, is not the responsibility of the elevator contractor or manufacturer. 4) The interface of the hoistway wall with the hoistway entrance shall be in strict compliance with the entrance manufacturer's requirements in order to retain fire rating and label validity of the elevator hoistway doors and frame. 5) Hoistway walls at entrances should be left open for the full width of the shaft until after door sills and frames are set in place. If this is not feasible, leave a 54"W x 92"H rough opening. 6) Filling and grouting by General Contractor. 28½" Minimum Return Side Rough Opening 25½" Minimum Strike Side Rough Opening Double ⅜" Sheetrock Minimum Double 2 x 10 Header 1" Sheetrock 6" Typical Hoistway Sill Line 2" 1" Sheetrock Double ⅜" Sheetrock 92" Above Finished Floor Masonry Construction Sill Anchors: (6) ⅜" x 3" Wedge Concrete Anchors Wood/Drywall Construction Sill Anchors: (6) ⅜" x 4" Lag Bolts, Zinc Finished Flooring 2½" 6" ¾" Finished Flooring 6" ¾" 4⅞" 8⅛" 4⅞" 8⅛" 2½" Concrete Slab Hoistway Sill Line Two 2 x 10s Behind Sheetrock Hoistway Sill Line 8 symmetryelevator.com 877.375.1428

Machine Room for Hydraulic Drive Standard & Compact Hydraulic Drive Standard Machine Room Hydraulic Drive Compact Machine Room Hydraulic Line & Electrical to Hoistway ½" ¾" Plywood Backing Behind Drywall 48" ½" ¾" Plywood Backing Behind Drywall Hydraulic Line & Electrical to Hoistway 48" Main Control Box Main Line & Car Light Disconnects Main Line & Car Light Disconnects 48" Hydraulic Power Unit 24" Light Hydraulic Power Unit Light Switch & Duplex Receptacle Light Light Switch & Duplex Receptacle 6" 3'0" Minimum Self-Closing, Self-Locking Door 6" Motor Controller 3'0" Minimum Self-Closing, Self-Locking Door Main Line Disc. SINGLE PHASE 208/230 VAC, 30 amp, Single Phase (3-Wire Dedicated Circuit)* or THREE PHASE 208 VAC, 20 amp, Three Phase (4-Wire Dedicated Circuit)* Motor Controller Main Line Disc. Car Lighting Disc. SINGLE PHASE 208/230 VAC, 30 amp, Single Phase (3-Wire Dedicated Circuit)* or THREE PHASE 208 VAC, 20 amp, Three Phase (4-Wire Dedicated Circuit)* 115 VAC, 15 amp, Single Phase (Dedicated Circuit)* Telephone Service for Elevator Travel Cable Car Lighting Disc. 115 VAC, 15 amp, Single Phase (Dedicated Circuit)* *Feeding breaker must not be a G.F.I. Telephone Service for Elevator Travel Cable *Feeding breaker must not be a G.F.I. Notes: 1) The Elevator Machine Room location and layout must meet the code requirements defined by the local authority having jurisdiction. 2) 30"W x 36"D clear working space in front of the Motor Controller and Disconnects as required by National Electrical Code (NFPA 70). 3) The Disconnects and Light Switch must be located on the strike side of the Machine Room Door. 4) The Hydraulic Power Unit must be located within 40'0" of the Cylinder. 5) The Machine Room must be free of all equipment not related to the Elevator. 6) The minimum Machine Room headroom is 7'0". 7) The Machine Room must be maintained between 50 F and 80 F, with relative humidity from 5 to 95%, non-condensing. Hydraulic Power Unit Motor Controller 22"W x 30"H x 8"D Hydraulic Power Unit 33½"W x 24¼"H x 12¾"D Main Line Disconnect Single Phase Square D H322N or Equivalent 2 Pole with Auxiliary Contact or 3 Pole Three Phase Square D H321N or Equivalent 3 Pole with Auxiliary Contact Car Light Disconnect Square D G221N or Equivalent symmetryelevator.com 877.375.1428 9

Hoistway Typical Rail Backing Construction Each backing member is constructed of three 2 x 12s and two 2 x 6s on each end, laminated using wood glue and #8 x 2¾" screws (minimum). Each backing member constructed of three 2 x 12s and two 2 x 6s on each end, laminated using wood glue and #8 x 2¾" screws (minimum) Finished Flooring Overhead (Finished Floor to Finished Ceiling) Typical rail backing constructed of three 2 x 12s laminated between two 2 x 6s using wood glue and screws. 18" 18" 10⅜" Bumpers Ram T-Rails 4½" 15" 15" 5¾" -¼ +¾ Finished Flooring Total Car Travel (Finished Floor to Finished Floor) 44⅞" 40⅞" 36" Drywall flush to Pit Wall Pit Depth (From Finished Floor) R1 191# Static Rail Reaction (per rail) R2 498# 10 symmetryelevator.com 877.375.1428

Hoistway Construction Outline Rail Backing & General Hoistway Provide adequate rail backing per drawings. For vertical spans between floor systems that exceed 10'0", please consult a structural engineer. The wall must be capable of supporting the loads without deflecting more than ⅛". The hoistway must be constructed square and plumb within ⅛" tolerance throughout. The hoistway must be free of any obstructions not related to the operation of the elevator (i.e. sprinklers, pipes, ducts, etc.). The structure of the hoistway must allow for installation of a chain hoist to transfer materials during installation. The maximum rail bracket spacing is 6'0". Pit Floor Provide a pit floor at a minimum of 13" (14 inches with buffer springs) from the top of the finished floor to the highest point in the pit. If required, the pit shall have means to prevent the collection of ground water. If provided with fire service, a drain or sump pump shall be provided to remove 3,000 gallons of water per hour. Provide a pit floor capable of supporting the loads below: - The maximum vertical force imposed on each guide rail upon application of the safety is approximately 4,800 lbs. for a total floor impact of 9,600 lbs. This load is applied at the respective T-rail locations on the base plate. - The impact load imposed on each buffer or bumper assembly is approximately 3,300 lbs. for a total floor impact load of 6,600 lbs. This load is applied at the respective buffer or bumper floor plate locations. - The approximate overall static net vertical load from the elevator system is 3,760 lbs. This value includes the capacity, car, sling, ram, ram's header and fluid weights and is applied at the ram location on the base plate. Overhead Provide a minimum overhead of 8'10" (106") for existing construction. Provide a minimum overhead of 11'0" for new construction. Please note that this guide is for planning purposes only, applies exclusively to national code and should not be used for construction. Prior to construction, please contact your local Symmetry Elevating Solutions representative and request a job-specific set of elevator plans to ensure that you obtain the accurate dimensions and requirements for your project. Your representative will also assist you to identify resources to ensure that your project plans will comply with the applicable state and local codes and the permitting authorities. symmetryelevator.com 877.375.1428 11

Hoistway Single Opening Depth Rail C/L 54" Minimum Rough Opening 7½" 36" Clear Opening 10½" Door C/L C D B COP A Width Single Opening Rail Left, Right-Hand Door (shown) Rail Right, Left-Hand Door (opposite) Car Size Width* Depth Rail C/L Door C/L 42x54 66" 72" 40¾" 40½" 42x60 66" 78" 43¾" 40½" 48x54 68" 72" 40¾" 42½" 2017 Bella Elevator LLC. All rights reserved. 202.12/17 *Add 2 inches to width if a Pit Ladder is required. 12 symmetryelevator.com 877.375.1428

Hoistway Opposite Opening Depth Rail C/L 54" Minimum Rough Opening 7½" 36" Clear Opening 10½" Door C/L C D B COP A Door C/L 7½" 36" Clear Opening 10½" 54" Minimum Rough Opening Width Opposite Opening Rail Left, Right-Hand Door, Left-Hand Door Rail Right, Left-Hand Door, Right-Hand Door Car Size Width* Depth Rail C/L Door C/L 42x54 66" 81½" 40¾" 40½" 42x60 66" 87½" 43¾" 40½" 48x54 68" 81½" 40¾" 42½" *Add 2 inches to width if a Pit Ladder is required. symmetryelevator.com 877.375.1428 13

Hoistway 90 Opening Depth Rail C/L COP C D B A Width Door A C/L 9" 36" Clear Opening 9" 54" Minimum Rough Opening Door B C/L 90 Opening Rail Right, Left-Hand Doors (shown) Rail Left, Right-Hand Doors (opposite) Car Size Width* Depth Rail C/L Door A C/L Door B C/L 51x51 79" 73½" 40" 36½" 47½" *Add 2 inches to width if a Pit Ladder is required. 14 symmetryelevator.com 877.375.1428

Notes symmetryelevator.com 877.375.1428 15

AIA Continuing Education symmetryelevator.com/aia Symmetry offers in-person and online course options to obtain continuing education credits. Each completed course is worth 1 (one) LU/A HSW/SD credit and provides a detailed review of residential elevators, vertical wheelchair lifts and limited use/limited application (LU/LA) elevators. Our continuing education AIA courses also address specification, code application, suitability of product type and the direct governance and guidelines of the ADA, ANSI and ASME. symmetryelevator.com 877.375.1428