CEM Gilles Gonnet Ecomesure, B.P. 13, F Briis Sous Forges, France telephone: fax:

Similar documents
WBEA Standard Operating Procedure

REAL-TIME DUST MONITOR TEOM 1405-F

DETERMINATION OF CONCENTRATION AND MASS FLOW OF PARTICULATE MATTER IN FLUE GAS FOR STATIONARY SOURCE EMISSIONS

Emissions Testing Report 2015

CAM does have exemptions for certain emission units as follows: Page 1 of 8

ABSTRACT INTRODUCTION

2nd Quarter Emissions Testing Report 2013

Comparison of Dry Sorbent Injection of Sodium Bicarbonate, Lime, and Carbon and Their Control of Dioxins/Furans, Mercury, Chlorides and Sulfur Dioxide

Air Quality Measurement Methods. Tim Morphy Regional Manager Thermo Electron October 20 th, 2006

TECHNICAL DATA SHEET

Mercury Sampling: A Comparison of Common Test Methods

2nd Quarter Emissions Testing Report 2016

PRODUCT CONFORMITY CERTIFICATE

Particulate Matter (PM) CEMS

Title: Operation of ACCU System Particulate Matter sampler in Ambient Air in conjunction with the Tapered Element Oscillating Microbalance (TEOM)

Emissions Testing Report

EPA Method 1 Field Procedures Example:

BetaGuard PM Measuring Particulate Continuously

A Comparison of Proposed PM CPMS Limits

June 8, Submitted to: The Environmental Protection Agency Research Triangle Park, NC. Prepared by:

Ambient Air Monitoring

INTHUU MEASUREMENTS CC

John Downs Environmental Manager, B&W PGG, KVB-Enertec Products. January 29, 2015

Cambridge Environmental Technologies 105 Goodwill Road Cambridge, MD Tel:

WEATHER MONITORING. Competitive rates available for long term hire. Hire rate Per week Per month

Sorbents Evaluation Testing Facilities. 95% removal efficiency or an emission standard of lbs/gw h by 2012, while

: Industrial Boiler MACT: CEM Requirements. Dan Kietzer: SICK Process Automation

Kendal Power Station Units No. 2 & 6 Particulate Emission Monitor Correlations. 30th September 2016 Report No. RSL224

CHAPTER 1 INTRODUCTION

This document is a preview generated by EVS

Particulate and Emission Monitoring Solutions

Particulate Monitors and Samplers

Compact flue gas analyser: testo 300 M-I

New Measurement Engineering For Monitoring Emissions In Industry

testo 350 M testo 350 XL

PM Compliance Options for MACT and MATS Rules. Ed McCall PCME

Proposed Guidelines for the Reduction of Nitrogen Oxide Emissions from Natural Gas fuelled Stationary Combustion Turbines

metals temperature limits.

CEMS for Measurement of Ammonia, SO 3, and Low Level NOx

Fully Extractive Vs. Dilution Extractive CEMS

Prima PRO process mass spectrometer

PORTABLE FLUE GAS ANALYZER

Training for Personnel to the MCERTS standard Level 1 Technician and Level 2- Team Leader. Syllabus

Highly efficient flue gas analyzer

Guidelines for Continuous Emission Monitoring Systems

Improving Steel Reheat Furnace Performance with the ZoloSCAN-RHT Combustion Monitoring System

Southwest Clean Air Agency NE 99 th St, Suite 1294, Vancouver, WA 98682

Fine particle measuring system

THE LEADER IN PERFORMANCE INDOOR AIR QUALITY MEASUREMENTS

LANCOM4 PORTABLE FLUE GAS MONITORING. NO NO2 NOx CO2 H2S SO2 CxHy. CO low CO high O 2 QUALITY CUSTOMER SOLUTIONS

TUV Certified FTIR CEM and Ultra Low Level HCl CEM for Combustion Facilities

GAS 3050P NDIR FLUE GAS

27.0 SAMPLING AND TESTING METHODS

Flow Test Data Book and Flow Handbook for 405 Compact Orifice Series and 1595 Conditioning Orifice Plate

PRODUCT CONFORMITY CERTIFICATE

Mercury Monitoring in a Cement Kiln

Compilation and Evaluation of NSSGA Haul Road PM10 and PM2.5 Emission Factor Test Data

Peerless Europe. Separation and Filtration

INVENTION ON SAMPLING BY YUNEL

METHOD 3 - GAS ANALYSIS FOR THE DETERMINATION OF DRY MOLECULAR WEIGHT. NOTE: This method does not include all of the

TruePeak TDLS200. NH 3 Slip Measurement. <Document Number> Copyright Yokogawa Electric Corporation <date/time>

CHAPTER 2 - Air Quality Trends and Comparisons

Federal Ministry for the Environment, Nature Conservation and Nuclear Safety

Particulate Matter Measurements Made using the Filter Dynamics Measurement System (FDMS), 2005

Transfield Services Limited

METHOD 201A - DETERMINATION OF PM EMISSIONS. 1.1 Applicability. This method applies to the in-stack measurement of

Sampler with PM 2.5 pre-separator

Performance Standards for Indicative Ambient Particulate Monitors Environment Agency July 2012 Version 2

TEST REPORT. EVALUATION CENTER Intertek Testing Services NA Inc Murphy Drive Middleton, WI 53562

Flow Rate Measurement In Emissions Monitoring

Guido Baum Dr. Peter Wilbring

COLow COHigh COLow/H comp NO NOx NO2 CO2 H2S SO2 CXHY LANCOM 4. Portable Flue Gas Monitoring.

Coal Fired Boiler Optimization and the Impact on Emission Control Devices

Modified Draft Indian Standard METHODS FOR CHEMICAL ANALYSIS OF STEELS

ABB Measurement & Analytics Monitoring cement plant stack emissions using FTIR

Combustion Control and Safety A comparison between Zirconium Oxide/Catalytic and Tunable Diode (TDL) Technologies Dr Stephen Firth / Rhys Jenkins

COLow COHigh COLow/H 2 NO 2 CO 2 H 2 S SO 2 C X H Y LANCOM 4. Portable Flue Gas Monitoring. comp NO NOx

Pulverized Coal Extractive Testing Methods Evaluation at the EPRI Coal Flow Loop

The Paradigm Case Method of Flowmeter Selection

PM2.5/10. APEX INSTRUMENTS, INC. Method for Determination of PM10 / PM2.5 Emissions (Constant Sampling Rate Procedure) Operator s Manual

Ambient Air Monitoring

EMISSION MEASUREMENT TECHNICAL INFORMATION CENTER NSPS TEST METHOD. Method 10 - Determination of Carbon Monoxide Emissions from Stationary Sources

DR1000 Flying Laboratory, Drone Environmental Monitoring

Advanced Instrumentation for Improved Plant Operation

Alabama Department of Environmental Management Air Division Planning Branch Emission Measurement Section

Preliminary Field Evaluation of EPA Method CTM-039 (PM2.5 Stack Sampling Method) Michael D. Buser and Derek P. Whitelock

Online data sheet MCS100E HW-C CEMS SOLUTIONS

PRODUCT CONFORMITY CERTIFICATE

Calibration of Light Scatter PM-CEMs to Satisfy PS-11 on Wet Stacks in Coal Fired EGUs

NEW ANALYZER FOR VISCOSITY MEASUREMENT AT REFERENCE TEMPERATURE

testo 330 Flue gas analysis with increased convenience and safety

ENERGY EFFICIENCY AND EMISSION REDUCTION OF TPM, PM 2.5, AND SO 2 FROM NATURAL GAS AND FUEL OIL FIRED BOILER EXHAUSTS

FACILITY PROFILE. New Brunswick Power Corporation for the Belledune Thermal Generating Station

EXAMPLE CALCULATIONS ASSOCIATED WITH THE MEASURMENT OF PHASE PARTITIONED SPECIES

LANCOM4 PORTABLE FLUE GAS MONITORING. NO NO2 NOx CO2 H2S SO2 CxHy. CO low CO high O 2 QUALITY CUSTOMER SOLUTIONS

An investigation into the use of EN for the determination of mass concentration of sulphur dioxide in stack emissions

MODEL 3340 LASER AEROSOL SPECTROMETER

PRODUCT CONFORMITY CERTIFICATE

Fpollutant-free zero air for analytical

Transcription:

CEM 2004 Real Time Measurement Of Particulate At Low Concentration From The Emission Of Stationary Source In The Steel And Power Industries Using a TEOM based Emissions Monitor Edward C. Burgher Rupprecht & Patashnick Co., Inc., 25 Corporate Circle, Albany, New York 12203 telephone: 518 452-0065 fax: 518 452-0065 email: eburgher@rpco.com Gilles Gonnet Ecomesure, B.P. 13, F-91640 Briis Sous Forges, France telephone: 33 1 6490 5555 fax: 33 1 6490 5566 email: ecomesur@aol.com Abstract Historically, measurements of particulate matter emissions from large stationary sources to comply with regulatory standards have employed a variety of methods depending on local agency requirements. More recently, with the establishment of regulatory norms for member states of the European Union, new methods have been established to provide a common basis for evaluating emission sources. In the USA, measurement of PM in emissions sources must be performed in accordance with U.S. EPA Method 5 or, in some cases, Method 17. As with the historical methods used in Europe and the USA, one of the newer methods, EN 13284-1 is based on filtration of particulate matter from a sample collected in-situ and isokinetically and requires the filter to be analyzed in a laboratory. The repeatability of a measurement made with any of the manual methods can be influenced adversely by factors including handling and transport of the filter, conditioning the filter before and after the sampling, and filter weighing. Also, because the measurement using the manual methods can only represent the average emission over the time period sampled, some important data like transitory concentration, stratification in the duct being sampled and the influence of the variation in parameters such as velocity, temperature and pressure on the particulate concentration is difficult or impossible to determine. Consequently, these limitations prompted customers of Rupprecht and Patashnick Company to request the company to develop a new method based on its patented Tapered Element Oscillating Microbalance (TEOM ) technology. While this new method, named the TEOM Series 7000 Source Particulate Monitor, provides an in-situ measurement collected by filtering source gases at isokinetic sampling conditions, the filter handling and weighing processes are completely different. A filter is placed on the top of the hollow-tube, oscillating element that is housed in a temperature controlled mass transducer assembly. As a carefully controlled vacuum is applied to the opposite end of the tapered element, source gases are extracted from the stack isokinetically and passed through the filter thereby capturing any particulate matter that was entrained in the sample gases. As the filter weight increases with the accumulation of particulate matter, the frequency of oscillation decreases. The change in frequency can be determined in real-time and converted to mass. Tracking mass change with collected sample volume over time permits calculation of mass concentration measurements that can be continuously reported and/or reported as an average over a user specified time period. The 1

method also incorporates procedures to dry the sample filter prior to and after the test in-situ and to recover any residual particulate matter left in the sample inlet during sampling thereby eliminating measurement errors introduced by filter handling, transport, etc. The ability of the Series 7000 method to measure and report data in real-time, can increase the amount of information available for characterization of process or control system variability or for calibration/correlation of indirect source measurement techniques such as triboelectric, optical or beta attenuation. Since it is important to understand the agreement between the different methods, and characterize the performance of the new, TEOM-based method this paper reports on a series of tests comparing the TEOM Series 7000 method to NF EN 13284-1 (for low concentration emissions), and NFX 44052 (for high concentration emissions). Results of the twelve test runs performed at the steel mill indicate that the Series 7000 provides a valid measurement equivalent to the reference methods and confirms the conclusion of other laboratories like the TÜV Rheinland who evaluated the Series 7000 in 2001. The evaluation also allowed evaluation of the Series 7000 for calibrating or auditing indirect automatic measuring systems for PM. Results of the tests also found that the Series 7000 method is well suited for the calibration of continuous measuring system using light scattering, transmissiometry or beta attenuation methods. The evaluation also showed that the monitor was robust and well adapted to the industrial environment while being easy to use and reliable. In a second series of tests, conducted at a large, coal-fired power plant located in the mid-western U.S., paired TEOM Series 7000 s were used to evaluate the systems capacity to make precise, real-time measurements with very short measurement time response. This precision evaluation was conducted in conjunction with assessment of stratification of a PM emissions source with respect to PM at the stack s normal sampling locations. This series of tests found excellent agreement between in the paired Series 7000 trains and showed how the Series 7000 method can be used to rapidly provide detailed information regarding stratification in a sampling plane. Results indicate that the sampling location would be suitable for installation of a PM AMS. Keywords: particulate matter, source sampling, stack sampling, real-time isokinetic PM measurement 2

Introduction As reported in a paper presented at CEM 2002 [Burgher, 2002], Rupprecht & Patashnick Co., Inc. developed a new instrumental method for measuring the particulate matter concentration in emission sources. This method, named the TEOM Series 7000 Source Particulate Monitor ( TEOM SPM ), incorporates R&P s patented TEOM technology and significantly enhances the amount of particulate matter emissions information that can be achieved from conducting an emissions testing program. For instance, when siting particulate matter continuous automatic measuring systems ( PM AMS ) it is important that the monitor is installed such that it will collect a representative sample regardless of the emission unit operating load. Secondly, as currently available PM AMS do not directly measure particulate matter mass, it is necessary to establish and verify the PM CEMS monitor accuracy over a range of operating conditions using methods such as EN-13284-1, EPA Method 5, ISO 9096 or the TEOM Series 7000. While TEOM SPM method provides an in-situ measurement collected by filtering source gases at isokinetic sampling conditions, as does recognized reference methods, the filter handling and weighing processes are completely different. With a TEOM SPM, a filter is placed on the top of the hollow-tube, oscillating element that is housed in a temperature controlled mass transducer assembly. The mass transducer is affixed to the end of a long sample probe that allows the mass transducer to be positioned in an emission source. By applying a carefully controlled vacuum to the opposite end of the tapered element, source gases are extracted from the stack isokinetically and passed through the sample filter. The filter captures any particulate matter present in the sample gas stream. As particulate matter accumulates, the filter weight increases which results in decreasing the tapered element oscillating frequency. The change in frequency can be determined in real-time and converted to mass. The result is mass concentration measurements that can be continuously reported and/or reported as an average over a user specified time period. Sample filter conditioning prior to and after the test can also be accomplished in-situ thereby eliminating measurement errors introduced by filter handling, transport, etc. The ability of the Series 7000 method to measure and report data in real-time, can increase the amount of information available for characterization of process or control system variability or for calibration/correlation of indirect source measurement techniques such as triboelectric, optical or beta attenuation. Since it is important to understand the agreement between the different methods used to make source PM emissions measurements, this paper reports on a series of tests designed to evaluate the performance of the Series 7000 method in comparison to NF EN 13284-1 (for low concentration emissions) and NFX 44052 (for high concentration emissions). In the first set of tests conducted by the laboratory LECES with the support of Ecomesure, the TEOM SPM method was compared to NF EN 13284-1 and to NFX 44052 in three different sources at a steel mill. Following the methods comparison tests, the Series 7000 was then used to calibrate an opacitybased continuous emissions monitor. It is also important that the reference method used to calibrate or audit an automatic measuring system for PM be inherently precise regardless of source conditions or test operators, etc. For example, while European standards such as EN 14181 and U.S. standards such as Performance Specification 11 (PS-11) do not explicitly include precision requirements for reference method measurements, the correlation of the automatic measurement system to the reference method can be significantly influenced by the precision of the reference method measurements. To demonstrate the precision of the TEOM Series 7000 method when used in real-world test 3

conditions, a second series of tests, conducted in the fall of 2003, were devised testing to evaluate the precision of method in an emission source produced by a coal-fired, power plant. This series of test were also designed to investigate particulate matter emissions stratification at two sampling locations normally used for emissions permit limit compliance determinations. Background - Series 7000 Measurement Theory, Configuration and Operation The Series 7000 allows sample collection inside a stack or duct through a filter while automatically maintaining isokinetic sampling conditions. The filter is affixed to one end of the mass transducer thereby allowing the collected particles to be weighed continuously resulting in a real-time measurement of the particle mass concentration. The TEOM mass transducer uses a short, straight inlet nozzle tube to isokinetically sample the flue gas transporting it just a few millimeters to the filter. The mass transducer is a hollow tube, clamped on one end and free to vibrate at the other. An exchangeable filter cartridge is place over the tip of the free end. This "tapered element" vibrates precisely at its natural resonant frequency. A precise electronic counter measures the frequency that has a direct relationship with mass. The relationship, expressed below, between mass and frequency can be derived from the simple harmonic oscillator equation [Patashnick, et.al, 1991]. f2 = K0 / m (1) where, f = frequency of oscillation K0 = calibration constant m = mass The calibration constant of the tapered element can be established by measuring the frequency of the tapered element with a filter of known mass installed and without a filter. Applying the relationship described by equation 1, the value of K0 can be calculated as shown below: K0 = (m2 - m1) / (1/f22-1/f12) (2) The tapered element system is constructed using non-fatiguing inert material and since K0 is a function of the (non-changing) physical characteristics of the tapered element system, the tapered element retains its calibration indefinitely. Once K 0 has been determined for a particular tapered element, it can be used for mass measurements. If the element is oscillating at the frequency of fa and has a frequency response of fb after an unknown mass is collected on the filter ( m ), m can be obtained as a function of fa, fb and Ko using the following equation: m = K 0 (1/f b 2-1/f a 2 ) (3) Tracking frequency with time provides the mass rate. When the mass rate is combined with the sample flow rate through the filter, mass concentration of the sampled gases can be directly calculated and in real-time. During normal operation, the temperature of the mass transducer is maintained a few degrees above the stack temperature to provide the frequency stability necessary for measurement of very small mass changes with high temporal resolution. To automatically control isokinetic sampling rates, the system incorporates measurement of source gas velocity, temperature and gas density / molecular weight. Velocity is measured with a "S" type Pitot tube assembly while the gas temperature is measured with a "K" type thermocouple. The gas density / molecular weight determination is provided by 4

measuring carbon dioxide with a non-dispersive, infrared monitor, oxygen with a paramagnetic monitor and moisture using a differential flow technique patented by R&P. All of these parameters are measured in real-time and input into the system's onboard computer to automatically perform the necessary calculations for computing isokinetic sampling rates. This information is then used to set and control the sampling rate using a measurement-control feedback loop. Case Study 1: R&P TEOM Series 7000 Evaluation in Steel Mill Source Emissions The major objectives of this study were: 1. Compare R&P TEOM Series 7000 to the European and French Manual Standard Method (FR EN 13284). 2. Evaluate TEOM 7000 real-time data output, ease of use for conducting emissions tests, and investigate capability for generating complete results on-site. 3. Evaluate TEOM 7000 as a method to calibrate an opacimeter as a PM mass emissions monitor. A series of twelve test runs in three different sources at a steel mill were conducted by the laboratory LECES with the support of Ecomesure to compare the TEOM SPM method to NF EN 13284-1 and to NFX 44052. All tests were performed under normal operating conditions of each emission unit. One TEOM SPM and one (1) manual reference method sampling train were operated such that simultaneous, co-located samples were collected. The TEOM SPM was operated in the continuous mode following the method instructions that are integrated into the system s computerized operating system. All Series 7000 test measurements and analyses were performed on-site. The manual method trains were operated in accordance with the NF EN13284-1 procedures. Results of the tests are shown below. Table 1 - Agglomeration Plant Test Results Test Run Dust Concentration (mg/m3) Relative Difference Automatic Method Manual Method (%) (TEOM SPM) (NF EN 13284-1) 1 79.9 85.5-6.5 2 123.1 115 7.0 3 88.4 101-12.5 4 74.4 83.3-10.7 Test Average 91.5 96.2-4.9 Test Conditions: Ave. stack temperature: 80 C Stack diameter: 2 m Ave. stack gas velocity 9 m/s Test Run Table 2 Coke Oven Test Results Dust Concentration (mg/m3) Automatic Method (TEOM SPM) Manual Method (NF EN 13284-1) Relative Difference (%) 5 3.0 3.5-14.3 6 4.0 4.6-13.0 Test Average 3.5 4.1-13.6 Test Conditions: Condition 5: Stack temperature: 35 C Stack diameter: 2 m Gas velocity: 18 m/s 5

Condition 6: Ave. stack temperature: Stack diameter: Ave. stack gas velocity: 184 C 4 m 5.3 m/s Table 3 - Electric Arc Furnace Test Results Test Run Dust concentration (mg/m3) Relative Difference Automatic Method Manual Method (%) (R&P 7000) (EN 13284-1) 7 6.8 6.0 13.3 8 56.2 56.9-1.2 9 5.4 5.0 8.0 10 0.9 0.7 28.6 11 2.1 1.8 16.7 12 2.2 2.0 10.0 Test Average 12.3 12.1 1.7 Test Conditions: Ave. stack temperature: 115 C Stack diameter: 2.5 m Ave. stack gas velocity: 11 m/s In a second set of tests conducted at the steel mill on an agglomeration unit, the TEOM SPM was used to calibrate two Oldham EP1000 Opacimeters. The Series 7000 was installed so that the sample extraction points were near the laser path area of the EP1000. The number of TEOM SPM sampling points on the sampling traverse axis was determined per the procedures specified in EN 13284-1. The duration of each TEOM SPM sample point was approximately five (5) minutes per point. Following the completion of each sample traverse line, the EP 1000 was adjusted to agree with the traverse average reported by the TEOM SPM. This process was repeated until the EP 1000 and R&P 7000 agreed. Result of each calibration test run are shown in the following tables. Time R&P 7000 (mg/m^3) Table 4 - Agglomerator Stack 1 Oldham EP 1000 (mg/m^3) Temperature ( C) Humidity (%) 8:29 to 9:41 42 81 124 4.7 10:05 to 11:12 31 61 121 8.8 13:40 to 14:38 58 45 123 4.7 15:22 to 16:24 53 34 127 5.5 10:33 to 10:48 37 46 121 6.6 11:28 to 11:41 28 40 114 10.1 13:44 to 14:13 43 45 116 6.5 Time R&P 7000 (mg/m^3) Table 5 - Agglomerator Stack 2 Oldham EP 1000 (mg/m^3) Temperature ( C) Humidity (%) 9:25 to 9:51 11 4 50 4.4 10:21 to 10:36 14 21 51 4.6 10:48 to 11:09 10 17 50 4.7 6

11:22 to 11:45 14 14 51 2.2 11:56 to 12:45 10 11 52 6.1 Case Study 2 : Comparison of TEOM SPM to EPA Method 5 and Stratification Analysis To illustrate the use of the TEOM SPM for conducting stratification studies to support siting of particulate matter automatic measurement systems (PM AMS), one set of paired train test runs was performed to investigate the degree of stratification in the sampling lines normally used for compliance testing. Prior to the stratification test runs, a set of paired train tests were conducted with the monitor s sample probes positioned at fixed locations near the center area of the stack for the purposes of evaluate the precision of the monitors used for stratification testing. Testing was conducted at a utility plant in the Mid-western U.S. that primarily uses a subbituminous coal from the Powder River Basin (PRB) in the State of Wyoming. During testing, the plant was operating at normal base load conditions. For the stratification tests, both TEOM SPM systems were operated in the traverse mode following the method instructions that are integrated into the system s computerized operating system. Stack gas velocity and temperature, sample gas molecular weight and gas density measurements used for calculation and setting of isokinetic sampling rates were determined using the TEOM SPM onboard measurement systems. For the precision test, both TEOM SPM systems were operated in the continuous mode. Stack gas velocity and temperature and sample gas density and molecular weight determinations were also made using the onboard measuring systems. All Series 7000 test measurements and analyses were performed on-site. First, to investigate the precision of the co-located TEOM SPM systems, two identically configured TEOM SPM systems were installed in adjacent sampling ports. The sample probes were inserted so that the probe nozzles were located at the centermost point of the stack as described in EPA Method 1. After each system s sample filter was desiccated to a stable mass, sample collection was started and test measurements were taken for approximately 1.5 hours. Care was taken to start and end the test period for each monitor simultaneously to minimize the potential for temporal changes in the PM emission rate to influence the precision analysis. For the second test investigating PM stratification, the monitors were installed and configured to measure PM concentrations at three discrete locations along the sample traverse lines for each test port. The probes for each monitor were installed in the same ports that were used for the co-location test. Sample measurements were taken for about 20 minutes at each traverse point for a total test time of approximately one hour. As with the precision test, each monitor was programmed to start and end sampling at the same time. Results from the co-located precision (co-located) test indicate that the difference between the two monitors, when located within the centroid area of the stack, is less than 8%, on average. Results for the traverse test found close agreement between the monitors at all points including the third traverse points were the same points used for the precision test. Since the two monitors showed good agreement during the fixed sample location test, and again at all three traverse point locations, it can be concluded that stratification of particulate matter is not present, at least in the areas tested. Results are summarized below in Table 6 and Figures 1 and 2. The charts shown in Figures 1 and 2 are constructed using the two-minute rolling average mass 7

concentration for each system clearly demonstrating the precision of the method even for very short term measurements. Test Type Traverse Point Table 6 - TEOM SPM Stratification Analysis Coal-fired Power Plant Midwestern U.S. Distance from Wall (m) TEOM SPM Unit 20102 conc. (mg/m 3 ) TEOM SPM Unit 20111 conc. (mg/m 3 ) Rel. % Diff. Co-located 2.76 21.1 19.6 7.7% Traverse 1 0.41 14.83 15.10-1.8% " 2 1.36 14.38 15.22-5.7% " 3 2.76 15.46 15.70-1.5% " Traverse Test Averages 17.54 16.77 4.5% Test Conditions: Co-located Test: Ave. stack temperature: 160.0 C Stack diameter: 9.3 m Ave. stack gas velocity: 19.7 m/s Traverse Test: Ave. stack temperature: 152.8 C Stack diameter: 9.3 m Ave. stack gas velocity: 19.0 m/s 40 Figure 1 - Fixed Sampling Location (Co-located) Test Coal-fired Power Plant Emission Source (Midwest U.S.) Precision Analysis 35 TEOM SPM Unit 20111 TEOM SPM Unit 20102 Mass Concentration (mg/m 3 ) 30 25 20 15 10 5 0 13:33 13:48 14:02 14:16 14:31 14:45 15:00 15:14 Time (hh:mm) 8

25 Figure 2 - Traverse Test Coal-fired Power Plant Emission Source (Midwest U.S.) Stratification Analysis TEOM SPM Unit 20102 TEOM SPM Unit 20111 20 Mass Concentration (mg/m 3 ) 15 10 5 Traverse Point 1 Unit 20102 ave. 14.8 mg/m 3 Unit 20111 ave. 15.1 mg/m 3 location: 0.41 m from wall Traverse Point 2 Unit 20102 ave. 14.4 mg/m 3 Unit 20111 ave. 15.2 mg/m 3 location: 1.36 m from wall Traverse Point 3 Unit 20102 ave. 15.5 mg/m 3 Unit 20111 ave. 15.7 mg/m 3 location: 2.76 m from wall 0 11:05 11:12 11:19 11:26 11:34 11:41 11:48 11:55 12:02 12:10 Time (hh:mm) Conclusions The evaluation found that the Series 7000 method is well suited for the calibration of continuous measuring systems using light scattering, transmissiometry or beta attenuation methods. The evaluation also showed that the monitor was robust and well adapted to the industrial environment while being easy to use and reliable. Results of the test runs performed at the steel mill indicate that the Series 7000 provides a valid measurement equivalent to the reference methods and confirms the conclusion of other laboratories like the TÜV Rheinland who evaluated the Series 7000 in 2001. The evaluation also showed that the monitor was robust and well adapted to the industrial environment while being easy to use and reliable. Results of the testing conducted in the coal-fired power plant emission source showed excellent agreement between co-located Series 7000 monitors while also showing the sampling locations to be essentially non-stratified with respect to particulate matter. Furthermore, testing using the Series 7000 found that stratification analysis could be conducted very rapidly with high reliability thereby, minimizing impacts on plant operations while potentially reducing the overall costs of conducting these types of test programs. References 1. Burgher, E. Rupprecht E. Validation of a TEOM - based Source Particulate Monitor According to European Reference Method pren13284-1. Paper presented at CEM 2002 Conference 2. Patashnick, H.; Rupprecht, E. Continuous PM-10 Measurements Using the Tapered Element Oscillating Microbalance, J. Air Waste Management Association 1991, 41, 1079-1083. 9