International Journal of Scientific & Engineering Research, Volume 7, Issue 10, October ISSN Pushover Analysis of RC Building

Similar documents
Comparative Study on Concentric Steel Braced Frame Structure due to Effect of Aspect Ratio using Pushover Analysis

Performance Based Seismic Design of Reinforced Concrete Building

PUSHOVER ANALYSIS FOR THE RC STRUCTURES WITH DIFFERENT ECCENTRICITY

Static Analysis of Multistoreyed RC Buildings By Using Pushover Methodology

NON-LINEAR STATIC PUSHOVER ANALYSIS FOR MULTI-STORED BUILDING BY USING ETABS

MODAL PUSHOVER ANALYSIS OF RC FRAME BUILDING WITH STAIRCASE AND ELEVATOR CORE

SEISMIC EVALUATION OF BUILDINGS WITH POSTTENSIONED BEAMS BY NON-LINEAR STATIC ANALYSIS

Pushover Analysis of High Rise Reinforced Concrete Building with and without Infill walls

Application of Pushover Analysis for Evaluating Seismic Performance of RC Building

Seismic Assessment of an RC Building Using Pushover Analysis

NONLINEAR STATIC ANALYSIS OF R.C.C. FRAMES (Software Implementation ETABS 9.7)

PERFORMANCE STUDY OF RETROFITTED GRAVITY LOAD DESIGNED WALL FRAME STRUCTURES (SC-140)

INTERNATIONAL JOURNAL OF CIVIL AND STRUCTURAL ENGINEERING Volume 2, No 2, 2011

Nonlinear Pushover Analysis of Steel Frame Structure Dahal, Purna P., Graduate Student Southern Illinois University, Carbondale

PERFORMANCE BASED SEISMIC EVALUATION OF MULTI-STOREYED REINFORCED CONCRETE BUILDINGS USING PUSHOVER ANALYSIS

Non-Linear Pushover Analysis of Flatslab Building by using Sap2000

PERFORMANCE- BASED SEISMIC DESIGN OF A BUILDING

Pushover analysis of RC frame structure using ETABS 9.7.1

Index terms Diagrid, Nonlinear Static Analysis, SAP 2000.

We are IntechOpen, the first native scientific publisher of Open Access books. International authors and editors. Our authors are among the TOP 1%

Seismic performance assessment of reinforced concrete buildings using pushover analysis

PUSHOVER ANALYSIS FOR PERFORMANCE BASED-SEISMIC DESIGN OF RC FRAMES WITH SHEAR WALLS

A Comparison of Basic Pushover Methods

OPTIMUM POSITION OF OUTRIGGER SYSTEM FOR HIGH RAISED RC BUILDINGS USING ETABS (PUSH OVER ANALYSIS)

NONLINEAR PERFORMANCE OF A TEN-STORY REINFORCED CONCRETE SPECIAL MOMENT RESISTING FRAME (SMRF)

COMPARATIVE STUDY OF REINFORCED CONCRETE SHEAR WALL ANALYSIS IN MULTI- STOREYED BUILDING WITH OPENINGS BY NONLINEAR METHODS

SEISMIC VULNERABILITY ASSESSMENT OF STEEL PIPE SUPPORT STRUCTURES

INTERNATIONAL JOURNAL OF PURE AND APPLIED RESEARCH IN ENGINEERING AND TECHNOLOGY

A COMPARATIVE STUDY ON SEISMIC PERFORMANCE EVALUATION OF IRREGULAR BUILDINGS WITH MOMENT RESISTING FRAMES AND DUAL SYSTEMS

Performance Based Inelastic Seismic Analysis of Buildings

Non-Linear Static Analysis of RCC Frames

International Journal of Engineering Research And Management (IJERM) ISSN: , Volume-03, Issue-11, November 2016

IJSRD - International Journal for Scientific Research & Development Vol. 4, Issue 05, 2016 ISSN (online):

EVALUATION OF NONLINEAR STATIC PROCEDURES FOR SEISMIC DESIGN OF BUILDINGS

Nonlinear Static Pushover Analysis of a Shear Wall Building in Madinah

REHABILITATION OF RC BUILDINGS USING STRUCTURAL WALLS

SEISMIC BEHAVIOR OF MULTI-STORY STRUCTURE WITH DIFFERENT TYPES OF SLABS

[Mohammed* et al., 5(8): August, 2016] ISSN: IC Value: 3.00 Impact Factor: 4.116

INFLUENCE OF BNWF SOIL MODELLING ON DYNAMIC BEHAVIOUR OF PILE FOUNDATION FOR RC FRAME WITH STRUCTURAL WALL

Performance based Displacement Limits for Reinforced Concrete Columns under Flexure

DETERMINATION OF MOMENT RESISTING RC FRAMES OF RESPONSE REDUCTION FACTORS

Effect of Standard No Rules for Moment Resisting Frames on the Elastic and Inelastic Behavior of Dual Steel Systems

Progressive Collapse Analysis of Reinforced Concrete Framed Structure

Seismic Performance Assessment of RCS Building By Pushover Analysis

Seismic Performance and Design of Linked Column Frame System (LCF)

PUSHOVER ANALYSIS OF A 19 STORY CONCRETE SHEAR WALL BUILDING

Study of Inelastic Behavior of Eccentrically Braced Frames under Non Linear Range

Linear and Nonlinear Seismic Analysis of a Tall Air Traffic Control (ATC) Tower

SEISMIC RETROFIT OF A TYPICAL REINFORCED CONCRETE BUILDING THROUGH FRP JACKETING OF EXTENDED RECTANGULAR COLUMNS

Effect of Concentric Braces on the Behaviour of Steel Structure by Pushover Analysis

Inelastic Versus Elastic Displacement-Based Intensity Measures for Seismic Analysis

ANALYSIS PROCEDURES FOR PERFORMANCED BASED DESIGN

Comparative Study on Conventional Frame and Combined Model Frame under High Earthquake Zone Arvind Belkeri 1, N.S.Inamdar 2

DESIGN AND COMPARISON OF A RESIDENTIAL BUILDING (G+10) FOR SEISMIC FORCES USING THE CODES: IS1893, EURO CODE8, ASCE 7-10 AND BRITISH CODE

Department of Civil Engineering, College of Civil Engineering, Semnan branch, Islamic Azad University, Semnan, Iran.

PROGRESSIVE COLLAPSE ANALYSIS OF A REINFORCED CONCRETE FRAME BUILDING

Seismic Behavior of High Rise Building for Soft Soil in All Seismic Zones Shaik Fayaz 1 Mrs. B.Ajitha 2

Determine Seismic Coefficients of Structural Using Pushover Nonlinear Analysis

Seismic Behavior of Soft First Storey

Parametric Study of Dual Structural System using NLTH Analysis Ismaeel Mohammed 1 S. M. Hashmi 2

SEISMIC CAPACITY EVALUATION OF POST-TENSIONED CONCRETE SLAB-COLUMN FRAME BUILDINGS BY PUSHOVER ANALYSIS

IJSRD - International Journal for Scientific Research & Development Vol. 4, Issue 10, 2016 ISSN (online):

Seismic Performance Evaluation of Torsionally Asymmetric Buildings

Descriptive Study of Pushover Analysis in RCC Structures of Rigid Joint

An Investigation of Seismic Response Reduction Factor for Earthquake Resistant Design

Analysis of Reinforced Concrete Building With Different Plan Shapes Resting on Sloping Ground

Analytical Study on Seismic Performance of Hybrid (DUAL) Structural System Subjected To Earthquake

INTERNATIONAL JOURNAL OF CIVIL AND STRUCTURAL ENGINEERING Volume 2, No 2, 2011

ON DRIFT LIMITS ASSOCIATED WITH DIFFERENT DAMAGE LEVELS. Ahmed GHOBARAH 1 ABSTRACT

STUDIES ON LOCATION OF SHEAR WALL IN BUILDINGS FOR STRUCTURAL STABILITY

EARTHQUAKE ANALYSIS OF A G+12 STOREY BUILDING WITH AND WITHOUT INFILL FOR BHUJ AND KOYNA EARTHQUAKE FUNCTIONS

HYBRID MOMENT RESISTING STEEL FRAMES

Pushover Analysis of Steel Frame Structures with Different Types of Bracing System

IJSRD - International Journal for Scientific Research & Development Vol. 2, Issue 09, 2014 ISSN (online):

PUSHOVER ANALYSIS OF BUILDING WITH INFILL WALL

Volume 1. HOW TO MAKE A DREAM HOUSE EARTHQUAKE RESISTANT Contents

Seismic Analysis and Design of Vertically Irregular RC Building Frames

REINFORCED CONCRETE WALL BOUNDARY ELEMENT LONGITUDINAL REINFORCING TERMINATION

Title. Author(s)ARDESHIR DEYLAMI; MOSTAFA FEGHHI. Issue Date Doc URL. Type. Note. File Information IRREGULARITY IN HEIGHT

Effect of Column Discontinuity on Base Shear and Displacement of Structure

Concept of Earthquake Resistant Design

Span Length Effect on Seismic Demand on Column Splices in Steel Moment Resisting Frames

IJSRD - International Journal for Scientific Research & Development Vol. 3, Issue 11, 2016 ISSN (online):

International Journal of Scientific & Engineering Research, Volume 5, Issue 5, May ISSN

Comparative study of Performance of RCC Multi-Storey Building for Koyna and Bhuj Earthquakes

Prediction of Initial Column Size for Reinforced Concrete Frame Buildings with Intermediate Drift

Assessment of P-Delta Effect on High Rise Buildings

Project Title. Comparative Study of Shear wall in multistoried

RESPONSE STUDY OF MULTI-STORIED BUILDINGS WITH PLAN IRREGULARITY SUBJECTED TO EARTHQUAKE AND WIND LOADS USING LINEAR STATIC ANALYSIS

THE DEGREE OF ACCURACY OF MODAL PUSHOVER ANALYSIS ON DUAL SYSTEM STRUCTURE INCORPORATING SHEAR WALL INELASTICITY

Behaviour and design of innovative hybrid coupled shear walls for steel buildings in seismic areas

Progressive Collapse of Reinforced Concrete Building

ctbuh.org/papers Evaluation of Progressive Collapse Resisting Capacity of Tall Buildings Title:

Effect of Interstorey Drift Limits on High Ductility in Seismic Design of Steel Moment Resisting Frames

TO STUDY THE PERFORMANCE OF HIGH-RISE BUILDING UNDER LATERAL LOAD WITH BARE FRAME AND SHEAR WALL WITH OPENINGS

Seismic Analysis of Truss Bridges with Tall Piers

Evaluation of Seismic Behavior for Low-Rise RC Moment Resisting Frame with Masonry Infill Walls

SEISMIC EFFECTS ON COUPLED SHEAR WALL STRUCTURE BY COUPLING BEAMS WITH SIDE BOLTED STEEL PLATES

Study of P-Delta Effect on Tall Steel Structure

PEER/CSSC Tall Building Design Case Study Building #1. J. Andrew Fry John Hooper Ron Klemencic Magnusson Klemencic Associates

Transcription:

International Journal of Scientific & Engineering Research, Volume 7, Issue 10, October-2016 88 Pushover Analysis of RC Building Dona Mary Daniel, Shemin T. John Abstract In this study the seismic response of a ten storied reinforced concrete building is analysed by displacement controlled pushover analysis. It is assumed to be located in seismic zone 3. The building frame is simulated and analysed using the structural analysis and design software SAP2000. In non-linear analysis, moment-curvature relationship is used to model plastic hinge behaviour. Thus it was developed for modelling the user defined hinges for beam and column sections. Moment (M) and interactive P-M hinges were assigned to the both ends of beam and column sections respectively. The lateral forces were obtained as per IS 1893 (Part1):2002 and applied to the building. Top node displacement is incremented step by step up to the limiting displacement to obtain the pushover curve and the sequence of formation of plastic hinges and failure of beams and columns were recorded. The analysis results including the pushover curve and hinge formation are discussed. The maximum base shear capacity was found to be higher than the design base shear and hinges were formed in beams prior to columns. Index Terms Capacity curve, Hinge formation, Load- moment interaction curve, Moment-curvature relationship, Pushover analysis. 1 INTRODUCTION ARTHQUAKE can cause greatest damages to humanity Eamong all the natural hazards. Since earthquake forces are unpredictable and random in nature, proper analysis of the structures must be ensured to withstand such loads. The recent developments in the performance based engineering design have brought the non-linear static (NSP) or pushover analysis to the forefront. It has replaced the conventional analysis procedures due to its simplicity and proved to be a useful and effective tool for assessing the real strength of structures. Pushover analysis can be either force controlled or displacement controlled. The pushover analysis can provide significant perception and understanding about the weak links in the structure. SAP2000 can perform static or dynamic, linear or nonlinear analysis of structural systems. To perform pushover analyses in SAP2000, users can create and apply hinge properties. 2 BUILDING DESCRIPTION SAP2000 is fully equipped with US, Canadian and International Design standards and codes like ACI concrete code, AISC building codes and AASHTO specifications [1]. These integrated design code features can easily generate wind, wave and seismic loads with comprehensive automatic steel and concrete design checks. Pushover analysis is a static non-linear technique in which the magnitude of the structural loading is incremented in the lateral direction of the structure according to a certain predefined pattern. Generally, it is assumed that the behaviour of the structure is controlled by its fundamental mode and the predefined pattern is expressed in terms of either story shear Number of bays along Y- axis : 4 or fundamental mode shape. FEMA-273 and its successor FE- Spacing along X and Y axis : 4 m MA-356 describe about the non-linear static procedure (NSP) Size of column : 300 x 800 mm or pushover analysis and its uses in the structural engineering Size of beam : 200 x 600 mm field. It is recommended as a standard tool for estimating Thickness of slab : 120 mm seismic demands for buildings [2]. Thickness of infill : 200 mm Grade of concrete : M20 Dona Mary Daniel is currently pursuing masters degree program in structural engineering in University of Kerala, India E-mail:dona.dnl7@gmail.coom Shemin T. John is currently working as Assistant Professor, Mar- Baselios college of engineering and technology, University of Kerala, India, E-mail: sheminjohn123@gmail.com In SAP2000, a frame element is modelled as a line element having linearly elastic properties and nonlinear forcedisplacement characteristics of individual frame elements are modelled as hinges represented by a series of straight line segments. There are three types of hinge properties in SAP2000. They are default hinge properties, user-defined hinge properties and generated hinge properties. Studies show that user defined hinge model gives better results than default hinge model [10]. Moment-curvature relationship is used to model plastic hinge behaviour in non-linear analysis. The seismic performance of a structure can be evaluated in terms of pushover curve, plastic hinge formation etc. The maximum base shear capacity of structure can be obtained from base shear versus roof displacement curve. The building used for analysis is a non-existing structure which is a ten storied RC building with floor to floor height of 3.2 m. The building is assumed to be located at seismic zone 3. The building is designed as a frame model with infill and constraints as fixed for the ground story columns. The building details and design data are given below. The plan and elevation of the building frame is shown in Fig. 1.and the 3D model is shown in Fig. 2. All dimensions are shown in mm. 2.1 Building Details Number of bays along X- axis : 6 2.2 Design Details Live Load :1.5kN/m 2 on roof and 3kN/m 2 on other floors Earthquake Load : As per IS 1893(Part 1):2002 Type of soil site : Medium

International Journal of Scientific & Engineering Research, Volume 7, Issue 10, October-2016 89 Seismic Zone : 3 3 MOMENT-CURVATURE PARAMETERS Moment-curvature relation is a basic tool in the calculation of deformations in flexural members. It has an important role to play in predicting the behaviour of reinforced concrete (RC) members under flexure. In non-linear analysis, it is used to model plastic hinge reinforced concrete (RC) members under flexure. In non-linear analysis, it is used to model plastic hinge behaviour. The materials used in the design were M20 grade concrete and Fe415 steel reinforcements. The cross section of the beam and column used for the analysis are shown in Fig. 3 and Fig. 4 respectively. All the sections in the structure are of same cross-section and reinforcement detailing. Fig. 3. Cross-section of beam Fig. 1. Elevation and plan of the building frame Fig. 4. Cross-section of column Fig. 2. 3-D building model in SAP2000 Moment curvature curve for beam and column sections are generated for a specific confining steel using the stressstrain curves for concrete and steel as per IS 456: 2000 using an iterative algorithm [9]. The moment-curvature curve generated for the column section for an axial load of 500kN and that for beam is depicted in Fig. 5 and Fig. 6 respectively. The moment curvature curves were developed for different axial loads and the axial load-moment values were used for developing the P-M interaction curve as shown in Fig. 7. Using these relationships Moment (M3) and interactive load-moment

International Journal of Scientific & Engineering Research, Volume 7, Issue 10, October-2016 90 (P-M3) hinges were defined and were assigned at both ends of each beam and column respectively. shown in Fig. 8. The salient points in the idealized momentcurvature curve can be defined as follows: The point A corresponds to the unloaded condition. The point B corresponds to the nominal yield strength and yield rotation. The point C corresponds to the ultimate strength and ultimate rotation, following which failure takes place. The point D corresponds to the residual strength, if any, in the member. It is usually limited to 20% of the yield strength, and ultimate rotation can be taken with that. The point E defines the maximum deformation capacity and is taken as ten times that at the yield point. Fig. 5. Moment-curvature curve for column Fig. 8. Idealized moment-curvature relationship 4 RESULT AND DISCUSSION Pushover analysis is carried out by vertical loading (gravity load) followed by a gradually increasing displacement controlled lateral load in both +x and +y direction. The design base shear calculated as per IS specifications is compared with the overall capacity of the structure obtained from the pushover curve. Fig. 6. Moment-curvature curve for beam The analysis results that include pushover curves, sequence of formation of hinges are briefly discussed below. Fig. 7. Load-moment interaction curve for column Moment-curvature parameters are used as the input for modeling the hinge properties and it can be idealized as 4.1 Pushover Curve The capacity curve also known as pushover curve is a plot of base shear versus displacement of the roof of the structure. From the pushover curve the maximum displacement at the roof and base reaction of the structure during displacement controlled analysis can be obtained. The capacity curve is a good indicator of the inelastic behaviour of the building beyond the elastic stageshows The pushover curves for building when analyzed by displacement controlled pushover analysis in both +x and +y direction are shown in Fig. 9 and Fig. 10. The Pushover curve shows that the building has high base shear capacity than the design base shear. Hence the building is safe for the designed level of earthquake The design base shear (V B ) was found to be 3435 kn and 2804 kn for x and y axis loading and the corresponding capacity obtained from the pushover curves are 3884.855 kn and 3534.256 kn respectively. The base shear capacity of the building was obtained to be 13.09% and 26.04% higher than design base shear

International Journal of Scientific & Engineering Research, Volume 7, Issue 10, October-2016 91 for x and y axis loading respectively. The maximum roof displacement were 167.35mm and 240.712mm for x and y axis loading respectively. maximum displacement was obtained in 205 incremental steps. The sequence of formation of hinges show that collapse mechanism occurs in beams earlier than columns in all cases. According to the concept of strong column weak beam, this failure mechanism is adaptable. Fig. 9. Pushover curve for x axis loading Fig. 10. Pushover curve for y axis loading 4.2 Hinge Formation Pushover analysis result gives the sequence of plastic hinge formation and state of hinge at various levels of building performance. This gives the information about the weakest member in the structure. So the member which is to be strengthened in case if the building need to be retrofitted can be thus identified. The detailing of the member can be done accordingly in order to achieve the desired pattern of failure of members in case of severe earthquakes. The Acceptance Criteria IO (Immediate Occupancy), LS (Life Safety) and CP (Collapse Prevention) is indicated by different colors to indicate the state of the hinge at various stages. Pushover analysis is carried out as displacement controlled where the maximum displacement is incremented in 1200 steps. Higher value of multiple steps is chosen to get a clear perception about the formation of hinges at each stage of displacement increment. Fig. 11 and Fig. 12 show the formation of hinges for various cases. In the case of pushover analysis with respect to x axis loading maximum displacement was obtained in 288 incremental steps where as for y axis loading Fig. 11 : Hinge formation for frame loaded in x direction (Total steps=288)

International Journal of Scientific & Engineering Research, Volume 7, Issue 10, October-2016 92 LOCATION OF HINGES FOR X AND Y AXIS LOADING 5 CONCLUSION Pushover analysis is an ideal method to explore the nonlinear behaviour of structure Moment-curvature relationship is an essential tool to define the user defined plastic hinge properties of the sections Load moment interaction curve is required for defining column hinges In all cases the maximum base shear capacity was higher than the design base shear Sequence of formation of hinges showed that localized collapse occur in beams prior to columns. 77.6 % and 84.56 % of hinges were formed within life safety level for X axis and Y axis loading respectively The building is acceptable and it is safe for the assumed level earthquake in terms of base shear capacity ACKNOWLEDGMENT The authors gratefully acknowledge Ms. Indu Geevar, Researcher in the field of structural engineering for her contribution. Figure 12 : Hinge formation for frame loaded in y direction (Total steps=205) From table 1, 77.6 % and 84.56 % of hinges were formed within life safety level for X axis and Y axis loading respectively. Only 20.2% and 12.8% of hinges were formed beyond the collapse prevention level respectively for X axis and Y axis loading. TABLE 1 REFERENCES [1] SAP 2000 manual (Version 14), CSI getting started with SAP2000, Computers and Structures, Inc. Berkeley, USA. [2] ATC-40, Seismic Evaluation and Retrofit of Concrete Buildings, Applied Technology Council, California, Volume 1, 1996 [3] ASCE 41-06(2007), Seismic rehabilitation of existing buildings, American Society of Civil Engineers, Virginia, USA [4] FEMA 356, Pre-standard and Commentary for the Seismic Rehabilitation of the Buildings, Federal Emergency Management Agency & American Society of Civil Engineers, November 2000. [5] Rohit,B., Pushover Analysis of Reinforced Concrete Frame, M.tech thesis, Thapar University, 2011 [6] Hyo-Gyoung,K. and Sun-Pil,K., Nonlinear analysis of RC beams based on moment curvature relation, Computers and Structures, 2002, pp. 615-628 [7] Shinde,D.N., Veena,N.V. and Pudale,Y.M., Pushover Analysis of Multi Story Building, International Journal of Research in Engineering and Technology, Vol.3, May 2014, pp.691-693 [8] IS1893-2002, Indian Standard Criteria for Earthquake Resistant Design of Structure, Bureau of Indian Standards, Fifth revision, New Delhi [9] Devdas,M., Modelling of RC elements for non-linear analysis [10] Inel,M., Hayri,B. O., Effects of plastic hinge properties in nonlinear analysis of reinforced concrete buildings, Engineering Structures, Vol. 28,2006, pp. 1494 1502 [11] Poluraju, P. and Nageswara,R, Pushover Analysis of Reinforced Concrete Frame Structure Using SAP 2000, International Journal of Earth Sciences and Engineering, Vol.4, pp.684-690,2011