Seismic behavior of Structures with Different Diaphragms and Infill Walls

Similar documents
Comparative Study on Concentric Steel Braced Frame Structure due to Effect of Aspect Ratio using Pushover Analysis

Static Analysis of Multistoreyed RC Buildings By Using Pushover Methodology

NON-LINEAR STATIC PUSHOVER ANALYSIS FOR MULTI-STORED BUILDING BY USING ETABS

Pushover Analysis of High Rise Reinforced Concrete Building with and without Infill walls

Seismic Behavior of Soft First Storey

MODAL PUSHOVER ANALYSIS OF RC FRAME BUILDING WITH STAIRCASE AND ELEVATOR CORE

Analytical Study on Seismic Performance of Hybrid (DUAL) Structural System Subjected To Earthquake

NONLINEAR PERFORMANCE OF A TEN-STORY REINFORCED CONCRETE SPECIAL MOMENT RESISTING FRAME (SMRF)

Application of Pushover Analysis for Evaluating Seismic Performance of RC Building

IJSRD - International Journal for Scientific Research & Development Vol. 4, Issue 05, 2016 ISSN (online):

IJSRD - International Journal for Scientific Research & Development Vol. 2, Issue 09, 2014 ISSN (online):

PUSHOVER ANALYSIS FOR THE RC STRUCTURES WITH DIFFERENT ECCENTRICITY

INTERNATIONAL JOURNAL OF PURE AND APPLIED RESEARCH IN ENGINEERING AND TECHNOLOGY

IJSRD - International Journal for Scientific Research & Development Vol. 2, Issue 07, 2014 ISSN (online):

SEISMIC EVALUATION OF BUILDINGS WITH POSTTENSIONED BEAMS BY NON-LINEAR STATIC ANALYSIS

INTERNATIONAL JOURNAL OF CIVIL AND STRUCTURAL ENGINEERING Volume 2, No 2, 2011

Seismic performance assessment of reinforced concrete buildings using pushover analysis

Pushover Analysis of Steel Frame Structures with Different Types of Bracing System

SEISMIC EVALUATION OF HIGH RISE STEEL STRUCTURES WITH AND WITHOUT BRACING

Evaluation of Seismic Behavior for Low-Rise RC Moment Resisting Frame with Masonry Infill Walls

Seismic Performance Evaluation of Torsionally Asymmetric Buildings

Evaluation of Earthquake Risk Buildings with Masonry Infill Panels

Non-Linear Pushover Analysis of Flatslab Building by using Sap2000

OPTIMUM POSITION OF OUTRIGGER SYSTEM FOR HIGH RAISED RC BUILDINGS USING ETABS (PUSH OVER ANALYSIS)

Seismic Base Isolation of RC Frame Structures With and Without Infill

TO STUDY THE PERFORMANCE OF HIGH-RISE BUILDING UNDER LATERAL LOAD WITH BARE FRAME AND SHEAR WALL WITH OPENINGS

Volume 1. HOW TO MAKE A DREAM HOUSE EARTHQUAKE RESISTANT Contents

Evaluation of Seismic Behavior for Multistoried RC Moment Resisting Frame with Open First Storey

PERFORMANCE STUDY OF RETROFITTED GRAVITY LOAD DESIGNED WALL FRAME STRUCTURES (SC-140)

Effect of soft storey on multistoried reinforced concrete building frame

IJSRD - International Journal for Scientific Research & Development Vol. 4, Issue 10, 2016 ISSN (online):

Effect of Column Discontinuity on Base Shear and Displacement of Structure

Seismic Analysis and Design of Vertically Irregular RC Building Frames

Seismic Analysis of Steel Frames with Different Bracings using ETSBS Software.

NONLINEAR STATIC ANALYSIS OF R.C.C. FRAMES (Software Implementation ETABS 9.7)

CAPACITY BASED DESIGN OF COLD FORMED STORAGE RACK STRUCTURES UNDER SEISMIC LOAD FOR RIGID AND SEMI RIGID CONNECTIONS

COMPARATIVE STUDY OF REINFORCED CONCRETE SHEAR WALL ANALYSIS IN MULTI- STOREYED BUILDING WITH OPENINGS BY NONLINEAR METHODS

Pushover analysis of RC frame structure using ETABS 9.7.1

Effects Of Vertical Geometric And Mass Irregularities In Structure

PUSHOVER ANALYSIS OF A 19 STORY CONCRETE SHEAR WALL BUILDING

Analysis of G+12 Structures with different material of Shear wall using SAP2000

Seismic Assessment of an RC Building Using Pushover Analysis

Descriptive Study of Pushover Analysis in RCC Structures of Rigid Joint

Assessment of P-Delta Effect on High Rise Buildings

PUSHOVER ANALYSIS OF BUILDING WITH INFILL WALL

SEISMIC BEHAVIOR OF MULTI-STORY STRUCTURE WITH DIFFERENT TYPES OF SLABS

Performance Based Seismic Design of Reinforced Concrete Building

Available at ISSN

PERFORMANCE BASED SEISMIC EVALUATION OF MULTI-STOREYED REINFORCED CONCRETE BUILDINGS USING PUSHOVER ANALYSIS

Analysis of Reinforced Concrete Building With Different Plan Shapes Resting on Sloping Ground

EARTHQUAKE ANALYSIS OF RCC BUILDINGS ON HILLY AREAS WITH VARYING SLOPES

Comparative Study of Equivalent Static Analysis and Response spectrum analysis on Flat Slab Using Etabs

[Mohammed* et al., 5(8): August, 2016] ISSN: IC Value: 3.00 Impact Factor: 4.116

Parametric Study of Dual Structural System using NLTH Analysis Ismaeel Mohammed 1 S. M. Hashmi 2

SEISMIC VULNERABILITY ASSESSMENT OF STEEL PIPE SUPPORT STRUCTURES

ON DRIFT LIMITS ASSOCIATED WITH DIFFERENT DAMAGE LEVELS. Ahmed GHOBARAH 1 ABSTRACT

Parasiya et al., International Journal of Advanced Engineering Research and Studies E-ISSN

Analysis of Various Steel Bracing Systems using Steel Sections for High Rise Structures

SEISMIC BEHAVIOUR OF RC BUILDING RESTING ON PLAIN AND SLOPING GROUND WITH BRACINGS AND SHEAR WALL

EVALUATION OF NONLINEAR STATIC PROCEDURES FOR SEISMIC DESIGN OF BUILDINGS

Index terms Diagrid, Nonlinear Static Analysis, SAP 2000.

EARTHQUAKE ANALYSIS OF A G+12 STOREY BUILDING WITH AND WITHOUT INFILL FOR BHUJ AND KOYNA EARTHQUAKE FUNCTIONS

Seismic Retrofitting of Building with Soft Storey and Floating Column

Stability Analysis of Rigid Steel Frames With and Without Bracing Systems under the Effect of Seismic and Wind Loads

A COMPARATIVE STUDY ON SEISMIC PERFORMANCE EVALUATION OF IRREGULAR BUILDINGS WITH MOMENT RESISTING FRAMES AND DUAL SYSTEMS

STUDIES ON LOCATION OF SHEAR WALL IN BUILDINGS FOR STRUCTURAL STABILITY

Comparative Study of Static and Dynamic Seismic Analysis of a Multistoried Building

SEISMIC ANALYSIS OF SIX STOREYED RC FRAMED BUILDING WITH BRACING SYSTEMS

Seismic Behavior of High Rise Building for Soft Soil in All Seismic Zones Shaik Fayaz 1 Mrs. B.Ajitha 2

Diaphragm Flexibility in Buildings with Shear Walls

Earthquake Analysis of High Rise Building with and Without In filled Walls

REHABILITATION OF RC BUILDINGS USING STRUCTURAL WALLS

Project Title. Comparative Study of Shear wall in multistoried

Study of P-Delta Effect on Tall Steel Structure

Seismic Analysis of High-Rise Building using Response Spectrum Method Pratik Bawankar 1

Seismic Analysis of Truss Bridges with Tall Piers

Nonlinear Pushover Analysis of Steel Frame Structure Dahal, Purna P., Graduate Student Southern Illinois University, Carbondale

EFFECT OF PLACEMENT AND OPENINGS IN SHEAR WALL ON THE DISPLACEMENT AT VARIOUS LEVELS IN A BUILDING SUBJECTED TO EARTHQUAKE LOADS

ctbuh.org/papers CTBUH Recommendations for the Seismic Design of High-Rise Buildings

Comparative Study on Conventional Frame and Combined Model Frame under High Earthquake Zone Arvind Belkeri 1, N.S.Inamdar 2

INTERNATIONAL JOURNAL OF CIVIL AND STRUCTURAL ENGINEERING Volume 2, No 2, 2011

SEISMIC EVALUATION OF RC MULTISTOREY BUILDING OF ASYMMETRIC PLAN WITH VISCO-ELASTIC DAMPER

A Study of Efficient Outrigger Structural Systems for Tall Buildings

THE EXTENDED N2 METHOD IN SEISMIC DESIGN OF STEEL FRAMES CONSIDERING SEMI-RIGID JOINTS

Modelling of RC moment resisting frames with precast-prestressed flooring system

optimal design of frp retrofitting for seismic resistant rc frames C. Chisari 1, C. Bedon 2 1

Seismic Performance Assessment of RCS Building By Pushover Analysis

PERFORMANCE OF LATERAL SYSTEMS ON TALL BUILDINGS

FEASIBILITY STUDY ON SEISMIC RESPONSE ESTIMATION OF DAMAGED R/C BUILDINGS BASED ON OBSERVATION DATA AND NUMERICAL ANALYSIS

PERFORMANCE- BASED SEISMIC DESIGN OF A BUILDING

Progressive Collapse Analysis of Reinforced Concrete Framed Structure

Comparative study of Performance of RCC Multi-Storey Building for Koyna and Bhuj Earthquakes

INFLUENCE OF BNWF SOIL MODELLING ON DYNAMIC BEHAVIOUR OF PILE FOUNDATION FOR RC FRAME WITH STRUCTURAL WALL

International Journal of Advance Engineering and Research Development. Comparative study for Seismic Analysis of building using different software

SEISMIC BEHAVIOR OF RC BUILDING FRAME WITH STEEL BRACING SYSTEM USING VARIOUS ARRANGEMENTS

Council on Tall Buildings

PROGRESSIVE COLLAPSE ANALYSIS OF A REINFORCED CONCRETE FRAME BUILDING

COMPARATIVE STUDY ON REGULAR & IRREGULAR STRUCTURES USING EQUIVALENT STATIC AND RESPONSE SPECTRUM METHODS

PEER Tall Building Seismic Design Guidelines

SEISMIC STRENGTHENING OF PARTIALLY INFILL RC BUILDINGS USING BRICK INSERTS - EXPERIMENTAL INVESTIGATION ON 3D MODEL STRUCTURE

Transcription:

IJSTE - International Journal of Science Technology & Engineering Volume 3 Issue 12 June 2017 ISSN (online): 2349-784X Seismic behavior of Structures with Different Diaphragms and Infill Walls Onkar A. Chavan PG Student MGM s College of Engineering and Technology India V. G. Sayagavi Assistant Professor MGM s College of Engineering and Technology India N. G. Gore P. J. Salunke Assistant Professor Assistant Professor MGM s College of Engineering and Technology India MGM s College of Engineering and Technology India Abstract In the present study, using nonlinear static (push over) analysis an investigation has been carried out to examine the behavior of an existing RC frame structure located in moderate seismic zone (zone-iii) of India and designed as per IS code 1893-2002 part I with different diaphragms with and without infills. Slabs are modeled as shell element, membrane with rigid diaphragms, membrane with semi rigid diaphragms and without any diaphragms. Infills were modeled using equivalent strut approach. Nonlinear static (pushover) analysis were carried out considering static earthquake load as per IS1893-2002(part-I), loads from predominant modes of vibration in both longitudinal and transverse direction using ETABS 9.7.2. Results in terms of pushover curve, capacity spectrum and performance points are tabulated for the each models and comparison has been done to evaluate the performance of the structure with different diaphragms and also performance difference with and without considering the stiffness of infills with different diaphragms. Results indicate that infill frame with different diaphragms is showing high performance in terms of base shear than the bare frame with different diaphragms. But bare frames are showing very good ductile behavior than the infill frame which is suffering from brittle failure due to the failure of open ground floor columns. Keywords: Bare Frame, Infill Frame, Base Shear, Nonlinearity, Displacement, Storey Drift, Plastic Hinges and Diaphragms I. INTRODUCTION A large number of buildings in India are constructed with masonry infills for functional and architectural reasons. Masonry infills are considered as non-structural elements and their stiffness contributions are generally ignored in practice. However, infill walls tend to interact with the frame when the structure is subjected to lateral loads, and also exhibit energy-dissipation characteristics under seismic loading. The term infilled frame can be defined as a composite structure obtained by combining a moment resisting plane frame and infill walls. However, it has been observed that, in practice, the infill stiffness is commonly ignored in frame analysis. This eventually results in an under-estimation of stiffness and natural frequency. Review of Literature Panneer Selvam et al. (2015) have studied the structural seismic response of a seven storey RC building in this paper. The RC building is analysed and designed for the gravity and lateral loads using Indian code. The designed structure is then evaluated for the seismic performance under the old and the revised code of practice using Pushover Analysis. The Displacement controlled Pushover Analysis was carried out and the Pushover Curve was obtained for the building in both X and Y directions. The Capacity Spectrum, Demand Spectrum and Performance point of the building, under old and revised seismic zone classification was found in both the direction using the analysis carried out in SAP. Authors have concluded from the analysis results that, the infill can completely change the distribution of damage throughout the structure. Also, simple modeling with equivalent diagonal struts, which carry loads only in compression, are able to simulate the global seismic response of the infilled frames, and is suitable for practical applications. It has been observed that the infills can have a beneficial effect on the structural response, when they are placed regularly throughout the structure, and that they do not cause shear failures of columns. Santhosh D. et al. (2014) have carried out the method of nonlinear static analysis to calculate the force-displacement relationship, or capacity curve, for a structural element. To determine the performance of RC frame structure, pushover analysis has been conducted by using ETABS. Three RC bare frame structures with 5, 10, 15 stories respectively are analyzed and compared for the base force and displacement of RC bare frame structure for the following stories. From the analysis performed in the mentioned paper it is understood that all the plastic hinges formed in the beams, columns are within the acceptable criteria of plastic hinge. Lateral deformations at the performance point are within the target displacement of the structure. Maximum total drift, maximum All rights reserved by www.ijste.org 36

inelastic drift, and structural stability do not exceed the limitations of the performance level. Hence, the present building is onsidered safe against the revised seismic provisions. Kavita Golghate et al. (2013) have performed nonlinear static pushover analysis for a IV selected reinforced concrete building. This requires the development of the force - deformation curve for the critical sections of beams, columns. The force deformation curves in flexure obtained from the reinforcement details were assigned for all the beams and columns. The Nonlinear properties of beams and columns have been evaluated and assigned to the computer model in SAP. The flexural default hinges and shear hinges were assigned to the beams at two ends. The interacting frame hinges type a coupled hinge property also assigned for all the columns at upper and lower ends. This paper concludes that the RC bare frame analyzed for the static nonlinear pushover cases, 5 storey frame can carry higher base force and at lower displacement it fails. The RC bare frame which is analyzed for the static nonlinear pushover cases, 15 storey frame can carry lower base force and at higher displacement it fails. Uva et al. (2012) have studied the participation of masonry infill panel to overall seismic resistance of building. In this paper, the authors have modeled the infill panel as equivalent strut of width using different mathematical models including the nonlinear force displacement relationship and compared the result. They also compared the effect of single and multiple struts on the performance of the building. The study conducted by the authors has concluded that infill panels simulated with wide struts are characterized by a brittle behaviour whereas lower values of width favour a ductile behaviour. They have stated that it assess the actual seismic performance of the framed structure in the presence of infill. It is evident to do the experimental investigation for the realistic assessment of masonry mechanical parameters to be introduced in the strut models and it is crucial to adopt multiple strut systems to assess the local shear failure in the column during the interactive behaviour of masonry with the frame. Infill Wall The typical multi-storey construction in India comprises reinforced concrete (RC) frames with brick masonry infills. Unreinforced masonry infill wall panels may not contribute towards resisting gravity loads, but contribute significantly, in terms of enhanced stiffness and strength under earthquake (or wind) induced lateral loading. However, in practice, the infill stiffness is commonly ignored in frame analysis, resulting in an under-estimation of stiffness and natural frequency. Also, the infills have energy dissipation characteristics that contribute to improved seismic resistance. It is instructive to study the implications of the common practice of ignoring the infill stiffness with regard to performance under seismic loading. II. OBJECTIVES The objective of the study is determine the weak zones in the structure and achieving the desired behavior of structure under extreme lateral loads by strengthening the weak zone by ways discussed in this paper. Understanding the response of frame and capacity demands of individual structural elements by determining the realistic force demands on potentially brittle elements, such as axial force demands on columns, force demands on brace connections, moment demands on beam to column connections, shear force demands in reinforced concrete beams, etc. It facilitates to achieve economy and value engineering while designing. Estimation of deformations demands for elements that have to deform in elastically in order to dissipate the energy imparted to the structure could be determined through the study. It is also necessary to find out the consequences of the strength deterioration of individual elements on behavior of the structural system to ensure and avoid undesired form of failure. Identifying the critical regions in which the deformation demands are expected to be high and that have to become the focus through detailing to ensure the ductile behavior. Identifying the strength discontinuities in plan and elevation will lead to changes in the dynamic characteristics in elastic range. Estimates of the inter story drifts that account for strength or stiffness discontinuities and that may be used to control the damages and to evaluate P-Delta effects. In present study, 9 RC framed models are studied under Pushover analysis using ETABS program. The study includes comparative analysis to study the behavior of RC frames with rigid and semi rigid diaphragms to access which gives more realistic results, Additionally, study also focuses on capturing the additional stiffness due to infill walls and its impact on the global response of the structure. For Pushover Analysis, horizontal static load as recommended by IS1893-2002 (part-1) and loads due to predominant modes of vibration. III. METHODOLOGY Three dimensional models representing the building structure are created in ETABS 9.7.2. Material, member properties are defined and assigned to the model. Base of the models are fixed for simplicity. Slabs are modelled as shell, rigid and semi rigid diaphragms for separate models. Masonry walls are modelled as equivalent diagonal strut element. Vertical loads are assigned to the building structure. Linear and nonlinear static analysis has been carried out for various three-dimensional and two dimensional building models considered in the analysis. Models Development Table - 1 Mentions the Conditions Considered In Developing the Model Mode No. Description 1 Bare Frame with semi-rigid diaphragm. All rights reserved by www.ijste.org 37

2 Bare Frame with rigid diaphragm. 3 Bare Frame with Shell. 4 Infill Frame with semi-rigid diaphragm with considering Nonlinear behavior of the infill. 5 Infill Frame with rigid diaphragm with considering Nonlinear behavior of the infill 6 Infill Frame with Shell with considering Nonlinear behavior of the infill. 7 Infill Frame with semi-rigid diaphragm without considering Nonlinear behavior of the infill. 8 Infill Frame with rigid diaphragm without considering Nonlinear behavior of the infill. 9 Infill Frame with Shell without considering Nonlinear behavior of the infill IV. MODELLING AND ANALYSIS Typical floor plan modelled in ETABS is as shown in figure below. Fig. 1: Typical floor plan Table - 2 Description of Model Floor height 3m Depth of Slab 0.15m Grade of Concrete M30 Grade of steel Fe415 Type of Structure (SMRF) Number of Stories G+12. Height of bottom storey 3.2 m Height of Intermediate Storey 3 m Height of parapet 1 m Thickness of slab 0.125 m Thickness of External wall 0.230 m Thickness of Internal wall 0.150 m Table - 3 Specifications of Materials Grade of reinforcing steel Fe415 Density of concrete 25 kn/m 3 Density of brick 20 kn/m 3 Grade of concrete for slab M 25 Grade of concrete for beams, columns M 30 All rights reserved by www.ijste.org 38

V. RESULTS AND DISCUSSION Evaluating the Post Elastic Behavior of Bare Frame with Different Diaphragms From the Figure 2 it is clearly evident that for pushover load EQX applied in positive X-direction, Model 3 showed nearly 49% more base shear than Model 1, 44.3% more base shear than Model 2.For pushover load represented in Figure 5.2 for EQY which is applied in positive Y direction Model 3 showed 56.43% more base shear than Model 1 and 57.2% more base shear than Model 2. But Model 2 and 1 showed better ductile behavior than Model 3. Fig. 2: Post elastic behavior of Bare Frame for Pushover Load-EQX Fig. 3: Post elastic behavior of Bare Frame for Pushover Load-EQY Evaluating the Post Elastic Behavior of Infill Frame-Without Considering the Nonlinearity of Infill with Different Diaphragms In below figure for the application of pushover load applied EQX applied in positive X-direction Model 6 showed 4.5% more base shear than Model 5, 7.3% more base shear than Model 4 There is not much variation in exhibiting ductile behavior between the models. In Figure 5 for the pushover load EQY Model 6 showed 5.3% more base shear than Model 5, 9.2% more base shear than Model 4.There is not much variation in exhibiting the ductile behavior between models. Fig. 4: elastic behavior of Infill Frame without considering nonlinearity of infill for Post Pushover Load-EQX Fig. 5: elastic behavior of Infill Frame without considering nonlinearity of infill for Post Pushover Load-EQY All rights reserved by www.ijste.org 39

Evaluating the Post Elastic Behavior of Infill Frame without considering the nonlinearity of Infill with Different Diaphragms In Figure 6 for static pushover load EQX for infill considering nonlinear behavior of infill, there is no significant influence of diaphragm this is due to the significant participation of infill in resisting the horizontal load rather than the structural elements. In Figure 7 for static pushover load EQY, Model 9 shows 10.75% more base shear than Model 8, 11.8% more base shear than Model 7. Model 7 and 8 showed better ductile behavior than Model 9. Fig. 6: Elastic behavior of Infill Frame with considering nonlinearity of infill for Post Pushover Load-EQX Fig. 7: elastic behavior of Infill Frame with considering nonlinearity of infill for Post Pushover Load-EQY VI. CONCLUSIONS From the analysis result of 9 base models following conclusion are arrived. 1) When comparing the performance of the RC frame with different diaphragms for bare frame and infill frame, RC frame with slab modeled as a shell is showing better performance in terms of base shear than the other models but relatively weak in showing ductile behavior both in longitudinal and transverse direction. 2) RC frame in which the slab modeled as membrane with rigid diaphragm is showing better ductile behavior than other models. 3) Failure mechanism of RC frame with slab as shell is concentrated more in open ground floor with failure of ground floor column much before the complete failure of beams where as in other models failure mechanism is distributed throughout the height. 4) Infill frame with different diaphragms is showing high performance in terms of base shear than the bare frame with different diaphragms. But bare frames are showing very good ductile behavior than the infill frame which is suffering from brittle failure due to the failure of open ground floor columns. 5) With these conclusion remarks we can say that variation of rigidity due to provision of big openings and discontinuities in slab can majorly alter the seismic performance of the structure and affect the distribution of horizontal loads in lateral force resisting system. All rights reserved by www.ijste.org 40

REFERENCES [1] C.P. Providakis., (2008), Pushover analysis of base-isolated steel concrete composite structures under near-fault excitations, Soil Dynamics and Earthquake Engineering, vol.28: pp 293-304. 72 [2] Chopra, A., and Goel R.K., (2005), Role of Higher Mode Pushover Analysis in Seismic Analysis of Buildings, Earthquake Spectrum, Vol-21, No.4 (1027-1041). [3] Deshpande, R. S., and Surekha, A. B., (2010), Seismic Analysis of RC Frame Building with Soft First Storey, Proceedings of the Seventh Structural Engineering Convention Annamalai University, Annamalainagar, T.N, India, [4] Dolsek, M., Fajfar, P., (2008), The Effect of Masonry Infill s on the Seismic Response of a Four-Storey Reinforced Concrete Frame-A Deterministic Assessment, Science Direct, Engineering Structures, Vol. 30, pp. 1991-2001. [5] Fiore A., Porco F., Raffaele D., Uva G., (2012) About the influence of the infill panels over the collapse mechanisms actived under pushover analyses: Two case studies. Engineering Structure; vol 39:pp 11-22. [6] Habibi A.R., Izadpanah., (2014) New method for the design of reinforced concrete moment resisting frames with damage control. Scientia Iranica ; vol 19:234-241. [7] Hasan R, Xu L, Grierson DE.,(2002) Pushover analysis for performance based seismic design. Computures and Structures; vol.80:pp 2483 2493. [8] Kazem Shakeri., Karim Tarbali., Mohtasham Mohebbi.,(2013) An adaptive modal pushover procedure for asymmetric-plan buildings. Engineering Structure; vol 36:pp160-172. [9] Kiran Kamath., B.S Spoorthi., A.RAvinash and BalakrishnaRao.,(2012) Response of RC Frame Building with Varying Soft Storey Subjected to Seismic Loading, Proceedings of National Conference on Contemporary Civil Engineering Research & Practices, Manipal Institute of Technology, Manipal. [10] Krawinkler and Seneviratna, (1998), Prons and Cons of a Pushover Analysis of Seismic Performance Evaluation, Engineering Structures, Vol.20, (452-464). [11] Mehmet Inel and Hayri Bayton Ozmen., (2006) Effects of plastic hinge properties in nonlinear analysis of reinforced concrete buildings. Engineering Structure; vol.28:pp1494-1502. [12] Moghaddam H., Hajirasouliha.I.,(2005) An investigation on the accuracy of pushover analysis for estimating the seismic deformation of braced steel frames., Journal of Constructional Steel Research;vol.62:pp343-351. [13] Mohammed S (2010), Finite Element Analysis of Unreinforced Masonry Walls, A1-Rafidain Engineering, Vol.18, No.4, Mosul University. [14] Niroomandi A., Maheri A., Mahmoud R. Maheri., Mahini S.S., (2010) Seismic performance of ordinary RC frames retrofitted at joints by FRP sheets, Engineering Structure;vol-32:pp 2326-2336. [15] Poluraju.P., Nageswara rao P.V.S.,(2011) Pushover analysis of reinforced concrete frame structure using SAP 2000. International Journal of Earth Sciences and Engineering; vol-4: pp 684-690. All rights reserved by www.ijste.org 41