EVALUATION OF SPLIT TENSILE STRENGTH OF HIGH STRENGTH FIBER IN REINFORCED CONCRETES

Similar documents
Evaluation of Residual Strength Properties of Steel Fiber Reinforced Concrete

Studies on ductility of RC beams in flexure and size effect

FIBER ADDITION AND ITS EFFECT ON CONCRETE STRENGTH

FAILURE MODE AND STRENGTH CHARACTERISTICS OF NON-GRADED COARSE AGGREGATE CONCRETE BEAMS

Strength of Normal Concrete Using Metallic and Synthetic Fibers Vikrant S. Vairagade* a and Kavita S. Kene b

EFFECT OF SILICA FUME ON VARIOUS PROPERTIES OF FIBRE REINFORCED CONCRETE

An Experimental Investigation on Mechanical Behavior of Macro Synthetic Fiber Reinforced Concrete

AN EXPERIMENTAL STUDY ON GLASS FIBRE REINFORCED CONCRETE

MECHANICAL PERFORMANCE OF RECYCLED PET FIBER REINFORCED CONCRETE WITH LOW VOLUME FRACTION

A Case Study on Strength Properties of Partially Replaced Recycled Aggregate and Steel Fibers to a Nominal Concrete

SUITABILITY OF SINTERED FLY ASH LIGHTWEIGHT AGGREGATE IN STRUCTURAL CONCRETE

STUDY OF RUBBER AGGREGATES IN CONCRETE: AN EXPERIMENTAL INVESTIGATION

Malaysian Journal of Civil Engineering 26(3): (2014) Department of Civil Engineering, Tripoli University, Tripoli, Libya 2

Energy Absorption Characteristics of Steel, Polypropylene and Hybrid Fiber Reinforced Concrete Prisms

Fracture Parameters of Coir Fibre Reinforced Concrete

Experimental Study of Reinforced Concrete (RC) Beams Strengthened by Carbon Fiber Reinforced Polymer (CFRP): Effect of Beam Size and Length of CFRP.

LIGHT WEIGHT CONCRETE WITH STEEL FIBER TO IMPROVE DUCTILE BEHAVIOUR

Physical Properties of Steel Fiber Reinforced Cement Composites Made with Fly Ash

STRENGTH AND BEHAVIOUR OF GEOPOLYMER CONCRETE BEAMS

EXPERIMENTAL STUDY ON FLEXURAL BEHAVIOUR OF REINFORCED CONCRETE HOLLOW CORE SANDWICH BEAMS

EFFECT OF REPLACEMENT OF CEMENT BY SILICA FUME ON THE STRENGTH PROPERTIES OF SIFCON PRODUCED FROM WASTE COILED STEEL FIBRES

MECHANICAL PROPERTIES OF FIBER REINFORCED CONCRETE BY PARTIAL REPLACEMENT OF FINE AGGREGATE WITH SEA SHELLS

Properties of Concrete Incorporating Recycled Post-Consumer Environmental Wastes

Cyclic behaviour of RC beams using SIFCON Sections

INTERNATIONAL JOURNAL OF CIVIL AND STRUCTURAL ENGINEERING Volume 4, No 2, 2013

Mix Design For Concrete Roads As Per IRC:

Behavior of Steel Fiber Reinforced Concrete for M-25 Grade

Properties of Fly Ash Based Coconut Fiber Composite

Experimental Study on Concrete and Cement Plaster Using Partial Replacement of Quarry Rock Dust as Fine Aggregate

DUCTILITY PERFORMANCE OF HIGH STRENGTH LIGHTWEIGHT CONCRETE PRODUCED FROM A MIXTURE OF OIL PALM SHELL AND PALM OIL CLINKER

Advance Concrete-Aggregate replaced by Coconut Shell

Behaviour of Fiber Reinforced Concrete Beams with Spliced Tension Steel Reinforcement

Experimental Investigation on Self Compacting Concrete by Partial Replacement of Fine Aggregate with Quarry Dust and Cement with Fly Ash

Fiber Reinforced Concrete (FRC)

INTERNATIONAL JOURNAL OF CIVIL AND STRUCTURAL ENGINEERING Volume 2, No 1, 2011

SELF COMPACTING CONCRETE WITH QUARRY DUST AS PARTIAL REPLACEMENT FOR FINE AGGREGATE AND FLYASH FOR CEMENT WITH FIBRE REINFORCEMENT

EFFECT OF COAL BOTTOM ASH AS SAND REPLACEMENT ON THE PROPERTIES OF CONCRETE WITH DIFFERENT W/C RATIO

An Experimental Investigation on Strength Properties of Concrete Replacing Natural Sand by M-Sand Using Silica Fume as an Admixture

A. HIGH-STRENGTH CONCRETE (HSC)

CONSTRUCTION AND DEMOLISION WASTE AS A REPLACEMENT OF FINE AGGREGATE IN CONCRETE

Effect of Chipped Rubber Aggregates on Performance of Concrete

BEHAVIOUR OF SPIRAL REINFORCED LIGHTWEIGHT AGGREGATE CONCRETE COLUMNS

STRENGTH AND PERMEABILITY RELATIONSHIP OF STEEL FIBROUS CONCRETE

Experimental Investigation on High Performance Concrete Using Silicafume And Flyash

A Study on Preparing Of High Performance Concrete Using Silica Fume and Fly Ash

EXPERIMENTAL STUDY ON PARTIAL REPLACEMENT OF CEMENT WITH METAKAOLIN AND SAND WITH QUARRY DUST OF REINFORCED CONCRETE BEAM.

Use of steel slag in concrete mixtures

STRENGTH PROPERTIES OF STEEL FIBER CONCRETE BY PARTIAL REPLACEMENT OF SILICA FUME

CONCRETE MIX DESIGN. Dr. B.N. KRISHNASWAMI TECHNICAL MEETING ON ORGANISED BY CIVIL ENGINEERS & ARCHITECTS ASSOCIATION, KUMBAKONAM

Effect of Different Types of Coarse Aggregates on Physical Properties of Mostly Used Grades M20, M25, M30 of Concrete

Nonlinear Analysis of Shear Dominant Prestressed Concrete Beams using ANSYS

Study of Fracture Properties of Cement Stabilized Macadam

Investigations on Some Properties of no-fines Concrete

STRENGTH PERFORMANCE AND BEHAVIOR OF CONCRETE CONTAINING INDUSTRIAL WASTES AS SUPPLEMENTARY CEMENTITIOUS MATERIAL (SCM)

Study of Modulus of Elasticity of Steel Fiber Reinforced Concrete

Impact of Admixture and Rice Husk Ash in Concrete Mix Design

CYCLIC BEHAVIOUR OF SANDWICH CONCRETE BEAM UNDER FLEXURAL LOADING

Effect of silica fume on the resistance to chloride ion penetration in high performance concrete

EFFECT OF WATER CEMENT RATIO ON THE WORKABILITY AND STRENGTH OF LOW STRENGTH QUARRY DUST CONCRETE

Abstract Concrete is most used construction material. enhance the strength to the concrete. Fibers act as crack

Effect of Magnesium Sulfate Attack on Basalt Fiber Reinforced Concrete with Partial to Full Replacement of Natural Sand by M - Sand

BEHAVIOR OF REINFORCED CEMENT CONCRETE BEAM WITH BAMBOO AS PARTIAL REPLACEMENT FOR REINFORCEMENT

PENETRATION RESISTANCE OF HYBRID FIBRE REINFORCED CONCRETE UNDER LOW VELOCITY IMPACT LOADING

Studying of Floating Concrete Report Fall

Statistical Modeling and Prediction of Compressive Strength of High Performance Concrete

IJSRD - International Journal for Scientific Research & Development Vol. 2, Issue 07, 2014 ISSN (online):

MATHEMATICAL MODELING FOR DURABILITY CHARACTERISTICS OF FLY ASH CONCRETE

Strength Characteristics of Concrete Mix by Replacing Fine Aggregates with Industrial Sand

A Study on Mechanical Properties of Sisal Fiber Reinforced Concrete

A DESIGN-BASED APPROACH TO ESTIMATE THE MOMENT-CURVATURE RELATIONSHIP OF FIBER REINFORCED ELEMENTS FAILING IN BENDING. Report A0.T0.UM.

Mix Design For Concrete Roads As Per IRC

DETERMINATION OF WORKABILITY OF FRESH CONCRETE BY SLUMP TEST

INVESTIGATION ON MECHANICAL BEHAVIOR OF CONCRETE WITH FIBERS MADE OF RECYCLED MATERIALS

NATURAL POLYMER AS WATERPROOFING COMPOUND IN CEMENT CONCRETE

Mechanical Properties of Block Masonry Units Manufactured From Different Kinds of Recycled Materials

Destructive and Non- Destructive Testing for Concrete in Sudan - A Comparative Study

The Mechanical Properties of High Strength Concrete for Box Girder Bridge Deck in Malaysia

Effect of High Performance Concrete Mixture on Behavior of Passive and Active Confined CFT

Effect of Steel Fibers on Plastic Shrinkage Cracking of Normal and High Strength Concretes

Experimental Studies on the Effect of Ceramic fine aggregate on the Strength properties of Concrete

Improvement of Self-Compacting Cement Slurry for Autoclaved SIFCON Containing High Volume Class C Fly Ash

STRENGTH PERFORMANCE OF CONCRETE USING BOTTOM ASH AS FINE AGGREGATE

Stress-Strain Behaviour of Structural Lightweight Concrete under Confinement

Effect of Calcium Nitrate on the Pozzolanic Properties of High Early Strength Concrete

Study of GFRG Panel and Its Strengthening

Study of Concrete Involving Use of Quarry dust as Partial Replacement of Fine Aggregates

Experimental Behaviour of Glass Fiber in Mechanical Properties of Slag Concrete

THE EFFECT OF ADDITION OF LIMESTONE POWDER ON THE PROPERTIES OF SELF-COMPACTING CONCRETE

STUDY ON SILICA FUME REPLACED CONCRETE WITH SUPER PLASTICIZER

Course Concrete Technology Course Code Theory Term Work POE Total Max. Marks Contact Hours/ week

BEHAVIOR OF REINFORCED CONCRETE BEAM WITH OPENING

Retrofitting of Reinforced Concrete Beam with Externally Bonded CFRP

Fundamentals of Concrete

Effect of Compressive Strength on Bond Behaviour of Steel Reinforcing Bar in Fiber Reinforced Concrete

Ultimate strength prediction for reinforced concrete slabs externally strengthened by fiber reinforced polymer (FRP)

Effect of Aggregate Size and Gradation on Compressive Strength of Normal Strength Concrete for Rigid Pavement

SHEAR BEHAVIOR OF RC BEAMS USING U-SHAPED UFC PERMANENT FORMWORK WITH SHEAR KEYS OR BOLTS

FLEXURAL IMPROVEMENT OF PLAIN CONCRETE BEAMS STRENGTHENED WITH HIGH PERFORMANCE FIBRE REINFORCED CONCRETE

CENTURION UNIVERSITY OF TECHNOLOGY AND MANAGEMENT LAB MANUAL CONCRETE STRUCTURE LAB. Department of civil engineering 1st EDITION

Transcription:

International Journal of Civil Engineering and Technology (IJCIET) Volume 9, Issue 4, April 2018, pp. 1664 1671, Article ID: IJCIET_09_04_184 Available online at http://www.iaeme.com/ijciet/issues.asp?jtype=ijciet&vtype=9&itype=4 ISSN Print: 0976-6308 and ISSN Online: 0976-6316 IAEME Publication Scopus Indexed EVALUATION OF SPLIT TENSILE STRENGTH OF HIGH STRENGTH FIBER IN REINFORCED CONCRETES N. Deepa M.Tech., PRIST University, Thanjavur, Tamilnadu, India A. Belciya Mary M.E., PRIST University, Thanjavur, Tamilnadu, India ABSTRACT This paper deals with the results of an experimental investigation of the split tensile strength with steel fiber blended with the high strength concrete (M60). The fiber content varied from 0.5 to 5 % by weight of cement at the interval of 0.5 %. Beams of 150mm x 150mm x 700 mm were tested for the flexural strength which was failed and broken in between middle third. The smaller broken piece was taken and tested for the split tensile test. A circular bar of 6mm diameter was placed at a distance 150mm from the finished end and loaded till the failure and the tensile strength was found. Results and expressions by regression analysis are obtained. A significant improvement in the split tensile strengths is observed due to inclusion of steel fibers in the concrete. A significant improvement in the split tensile strengths is observed due to inclusion of steel fibers in the concrete. Key words: High strength concrete, Steel Fiber, Volume fraction of fibers, SFRC, Split. Cite this Article: N. Deepa and A. Belciya Mary, Evaluation of Split Tensile Strength of High Strength Fiber in Reinforced Concretes, International Journal of Civil Engineering and Technology, 9(4), 2018, pp. 1664 1671. http://www.iaeme.com/ijciet/issues.asp?jtype=ijciet&vtype=9&itype=4 1. INTRODUCTION 1.1. General High strength concrete (HSC) is generally used for concrete with compressive strength higher than 42mpa (6000psi) which leads to the design of smaller sections. this in turn reduces the dead weight, allowing longer spans and more usable area of buildings. The increase in concrete strength reduces its ductility. the higher strength of concrete, the lower is its ductility. this inverse relation between strength and ductility is a serious drawback for the use of high strength concrete and a compromise between these two characteristics of concrete can be obtained by adding discontinuous fibers. also high strength concrete is known to manifest a http://www.iaeme.com/ijciet/index.asp 1664 editor@iaeme.com

N. Deepa and A. Belciya Mary more brittle behavior than normal strength concrete. when concrete cracks, the randomly oriented fibers arrest a micro-cracking mechanism and limit crack propagation, thus improving strength and ductility. Development of such type of concrete that has to meet special requirements and performance cannot be always achieved by using only conventional materials and procedure. The requirements may be the enhancement of characteristics such as placement and compaction without segregation, mechanical properties, toughness, durability and serviceability in severe environments. To improve properties of concrete, a new type of concrete known as fiber reinforced concrete is introduced. Fiber Reinforced Concrete (FRC) is a relative new composite material in which fibers are introduced in the matrix as micro reinforcement, so as to improve the tensile, cracking and other properties of concrete. Fiber reinforced concrete may be defined as the composite materials made with Portland cement, aggregate, and incorporating short discrete discontinuous fibers. Plain reinforced concrete is a brittle material due to this the structure having low ductility, low tensile strength and a low strain capacity. 2. LITERATURE REVIEW 2.1. General Balendran, Zhoe, Nadeem and Leung [1] Investigated the effectiveness of fiber inclusion in the improvement of mechanical performance of concrete with regard to concrete type and specimen size. Lightweight aggregate concrete, the limestone aggregate concrete with and without steel fibers were used in the study. The compressive strength of the concrete mixes varied between 90 and 115 MPa and the fiber content was 1% by volume. The increase in spitting tensile strength, flexural strength and toughness index for lightweight concrete seems much higher than that of normal aggregate concrete. BarrosandFigueiras[2] established flexural behavior of SFRC with fiber content of the concrete ranged from 0 to 60 kg/m3. Ghugal[3] studied effect of steel fibers on various strength of concrete. Author takes various percentage of steel fiber with four grades of mixes. For each mix cube, cylinder, beams and shear specimens are casted. GiuseppeCampion[4] he reported that an analytical model was proposed that is able to determine the flexural response of supported beams under four point bending tests. A simplified analytical model is presented that is able to calculate the load deflection curves and the maximum and ultimate deflections occurring in the case of shear or flexure failure. LokandXiao[5] demonstrated that how the first crack flexural strength Fcr and the ultimate flexural strength Fult can be derived from a constitutive stress- strain mode. The model is described in a separate study both strength Fcr and Fult are dependent on material and composite properties. Further stories are then conducted to derive a simplified form to asses the ultimate flexural strength of SFRC. Parviz Soroushian and Ziad Bayasi, [6] Investigated the flexural behavior of reinforced concrete beams containing steel fibers. They indicated that the ductility and the ultimate resistance are remarkably enhanced due to the addition of steel fibers. The design implication of fiber-reinforced concrete beams is also discussed & method for incorporating fiber effects in the flexural analysis of singly reinforced concrete beams. Sawant, Khan, Aher and Bundele [7] did comprehensive study of high strength fiber reinforced concrete under pullout strength and reported considerable improvement in the pullout strength. Sawant, http://www.iaeme.com/ijciet/index.asp 1665 editor@iaeme.com

Evaluation of Split Tensile Strength of High Strength Fiber in Reinforced Concretes Khan, Khan and Waykar [8] studied the behaviour of high strength fiber reinforced concrete under shear and observed that the inclusion of fiber has comparatively increased the shear strength of the concrete. 3. PRELIMINARY INVESTIGATION AND MIX DESIGN 3.1. Preliminary Investigation In this preliminary investigation tests was conducted for concrete materials, cement, fine aggregate, coarse aggregate, and water. based on the test results concrete mix design was designed. it was explained by the following chapters. Materials used The ingredients of concrete i.e. cement, fine aggregate and coarse aggregate are tested before put them in the work. The various tests have been conducted according to relevant Indian standard code of practice. All cement, sand, coarse aggregate (20mm), and coarse aggregate (10mm) measured with digital balance. The water is measured with measuring cylinder of capacity 1 liter and measuring jar of capacity 1000ml, 200ml. The Crimped Steel fiber is measured with digital balance of accuracy 1mg. Cement Ordinary portland cement of 53 grade. All the properties of cement are tested according to IS 12269-1987 [9] specifications having 7 days compressive strength of 45.20Mpa. Potable water Water available in the laboratory is used for mixing and curing of concrete. Natural sand Source from local Godavari river is used confirming to IS 383-1970 [10]. Aggregate Crushed black trap basalt rock of aggregate size 20mm down and 10mm down were used confirming to IS 383-1970 [10]. The fineness modulus of sand was 2.803 and those of 10mm and 20mm coarse aggregates were 7.52 Tests on fine aggregate As per IS code provision the following tests were carried out and test results are tabulated here. the discussions also mentioned here with 3.2. Fineness modulus of fine aggregate Fineness modulus is defined as the empirical value obtained by adding the cumulative percentage of the material retained by weight in each of a series of sieves and dividing the total thus obtained by 100. For good concrete, the value of fineness for the fine aggregate should be up to 2-3.50 1. 1kg of dry sand is taken. The sieves are arranged in the order as given in the observation table. 2.Pan is placed at the bottom. now, the aggregate is transfered to the top sieves and lip is kept. 3. The whole arrangement is kept in the mechanical sieve shaker and sieved for 15 min. 4. The arrangement retained in each sieve is weighted and noted down. 5. The fineness modulus is calculated as, http://www.iaeme.com/ijciet/index.asp 1666 editor@iaeme.com

N. Deepa and A. Belciya Mary 6. Fineness modulus = Total cumulative % retained / 100 Fineness modulus of coarse aggregate Fineness modulus is defined as the empirical volume obtained by adding the cumulative percentage of the material retained (by weight) in each of the sieves and dividing the total thus obtained by 100. 1. 2kg of coarse aggregate that passes through the 40mm sieves is taken. 2. Sieves are set in order 40mm, 20mm, 12.5mm, 10mm, 4.75mm, 2.36mm,1.18, 0.6, and pan. 3. Sieving is carried out manually not less than 2min. 4. The shaking is done with a varied motion. So that the material is kept moving over the sieve surface in frequently changing direction 5. The coarse aggregate, retained on each sieve is weighed 3.3. Mix Design (IS 10262-1982 ) Grade of concrete Design stipulations Grade designation : Types of cement : OPC 53 grade Maximum size of aggregate : 20mm Degree of supervision : good Type of exposure : mild Maximum water cement ratio : 0.3 Method of concrete placing : manual Chemical admixtures : not required Minimum cement condition : 380 kg/m3 Tests data for materials Specific gravity of cement ( ) = 3.15 Specific gravity of coarse aggregate ( ) = 2.78 Specific gravity of fine aggregate ( ) = 2.6 Water absorption of fine aggregate = 1.6% Water absorption of coarse aggregate = 1.21% Free moisture content of coarse aggregate = NIL Free moisture content of fine aggregate = NIL Target mean strength = 20 + 1.65* 4 = 26.60 N/ Water cement ratio From table 5 of IS 456-2000, maximum water cement ratio = 0.3 (mild exposure) w/c = 0.3 Cement content Water cement ratio = 0.3 http://www.iaeme.com/ijciet/index.asp 1667 editor@iaeme.com

Evaluation of Split Tensile Strength of High Strength Fiber in Reinforced Concretes Cement content = 129/0.3 =430 kg/ Water content From table 2, Water content = 129 liters 4. EXPERIMENTAL PROGRAM The present work is made to investigate experimentally and the following tests are carried out, namely compressive strength, split tensile strength and flexural strength tests. These experimental investigations comprises the addition of steel fiber with 0.5, 1.0, 1.5 and 2.0 percentages by total volume and have been attempted over the concrete specimens such as cubes, cylinders and beams respectively. The program consists of casting and testing of specimens for various mixes. A detailed test program and results of testing are presented in this paper. 4.1. Specimen Details Cube specimen of size 150mm x 150mm x 150mm for compressive strength, Cylinder specimen of diameter 150 mm diameter x 300 mm height and prism of size 100mm x 100mm x 500mm were cast to study the mechanical strength properties such as compressive, split tensile and flexural strength according to Indian standards. 5. TESTING OF CONCRETE Concrete is tested for both fresh and hardened concrete. in this project it has been conducted following tests are given. 1. Compression test 2. Residual strength test 3.Split tensile strength test 5.1. Compression Test A total of 45 cubes for compression test and 45 cylinders for split tensile test were tested in ASTM Compression testing machine of 3000 KN capacity in according to ASTM C39, the load was applied at the rate of 2.9 kn/sec. The test was conducted on 7, 14 and 28 days. The compressive strength values are taken as the average of three values for different mixers are shown in Figure1. Flexural strength test The Beams (Prism) was tested in Flexural strength testing machine of 100 kn capacity accordance with ASTM C 78 to determine the flexural strength of concrete with and without steel fiber under three point loading. The centre distance between supporting rollers for Beams (prism) as 400 mm and centre distance between loading rollers as 133 mm. The strength values at 28 days are shown in Figure 4. Durability characteristics such as sorptivity according to ASTM C 1585, sulphate and chloride resistance were studied by making cylinder and cube specimens for different percentage of steel fiber in volume fractions is done for 28 days curing according to ASTM C 267 and control concrete were compared with concrete specimens with steel fibers. 5.2. Residual Strength Test The Residual strength of fiber reinforced concrete was determined as per ASTM C 1399 07a procedure. A steel plate of 12mm thickness was kept below the specimen. The steel plate was used to help control the rate of deflection when the beam cracks. After the beam cracked in a http://www.iaeme.com/ijciet/index.asp 1668 editor@iaeme.com

N. Deepa and A. Belciya Mary specified manner, the steel plate was removed and the cracked beam was reloaded to obtain data to plot a reloading load deflection curve. If cracking had not occurred after reaching a deflection of 0.20 mm the test was discarded. The average residual strength (ARS) for each beam was calculated using the loads determined at reloading curve deflections of 0.50, 0.75, 1.00, and 1.25 mm. ARS= ((PA+PB+PC+PD)/4) X k Where: k=l/bd2 PA+PB+PC+PD = Sum of recorded loads at specified deflections L= Span length b= Average width of the beam d= Depth of the beam 5.3. Split Tensile Strength Test The tensile splitting strength was determined using broken half of a prism (beam) after it has been tested for flexural strength. The flexural beam brakes in between the middle third. The smaller piece of the broken specimen is taken and a 6mm mild steel bar is placed at a distance of 150mm from a finished end and loaded on the compression testing machine till the failure. The tests were conducted according to standard procedures. In this test, compressive line loads are applied along a vertical symmetrical plane setting up tensile stresses normal to plane, which causes splitting of specimen. The formula derived using theory of elasticity has been used to calculate the tensile strength of the time of splitting. The split tensile is well known indirect test used to determine the tensile strength of concrete. The indirect split tensile strength is calculated by the following formula. For Prism split tensile where ft = Tensile Strength P = Load at failure in D = Diameter of Cylinder or side of the cube Lc = length of the specimen At 28 days mathematical regression analysis equation for the split tensile strength is given as = -0.119 2 + 0.610 + 4.117 (2) 6. RESULT Experimental results and results of regression analysis by Eq. (1) and Eq. (2) at 28 days along with the percentage variation in split tensile strength are presented in Table 4.1 http://www.iaeme.com/ijciet/index.asp 1669 editor@iaeme.com

Evaluation of Split Tensile Strength of High Strength Fiber in Reinforced Concretes Table 4.1 Split tensile strength of concrete Mpa S.no Fiber content (%) Split tensile strength in N/ equivalent cubes % variation in split tensile strength at 28 days 28 days 1 0.0 4.05 0.00 2 0.5 4.24 4.65 3 1.0 4.61 13.72 4 1.5 5.17 27.68 5 2.0 4.95 22.10 6 2.5 4.83 19.31 7 3.0 4.72 16.52 8 3.5 4.64 14.42 9 4.0 4.55 12.33 10 4.5 4.44 9.54 11 5.0 4.32 6.75 From Table 4.1, it is observed that, the 28 days spilt tensile strength increased continuously up to 1.5 % Fiber content. The increase in strain is more than 50% which is significant. Hence the Fibers are best suitable for improving the spilt tensile strength of structural concrete. The variation of 28 days, spilt tensile Strength with respect to Fiber content is presented in Figure. 6. The percentage variation of spilt tensile strength over controlled concrete with respect to fiber content at 28 days is presented. 7. CONCLUSIONS Following conclusion are drawn based on the result discussed in the previous chapter. 1. The maximum percentage increase in split tensile strength, 27.68 %, with 1.5 % at 28 days of water curing. 2. Empirical expressions have been established to predict the values of flexural strength for SFRC in terms fiber content. 3. After testing the cubes under split the specimen were further stressed and broken into two pieces. It was observed that about 40% of the fibers were slipped and 20 % were broken. 4. For all fiber content, mode of failure was changed from brittle to ductile failure when subjected to all types of strengths in this study. 5. In general, the significant improvement in various strengths is observed with the inclusion of steel fibers in the plain concrete. However, maximum gain in flexural strength of concrete is found to depend upon the amount of fiber content. 6. The optimum fiber content to impart maximum gain in strength varies with type of the strength. REFERENCES [1] Balendran R.V., Zhou F.P., Nadeem A., A.Y.T. Leung, Influence of Steel Fibers on Strength and Ductility of Normal and Lightweight High Strength Concrete, Building and environment 37 (2002) 1361-1367. [2] Barros J.A.O. and Figuerias J.A., Flexural Behavior of SFRC: Testing and Modeling, Journal of materials in civil engineering Vol 11, No. 4, November 1999. [3] Ghugal, Y. M., Effects of Steel Fibers on Various Strengths of Concrete, Indian Concrete Institute Journal, Vol. 4, No. 3, 2003, pp. 23-29. http://www.iaeme.com/ijciet/index.asp 1670 editor@iaeme.com

N. Deepa and A. Belciya Mary [4] Campion G., Simplified Flexural Response of Steel Fiber-Reinforced Concrete Beams, Journal of materials in Civil Engineering. Vol 20, No. 4 ASCE / April 2008. [5] Lok T.S., Xiao J.R.,(1999), Flexural Strength Assessment of Steel Fiber Reinforced Concrete, Journal of materials in civil engineering Vol 11 No. 3, August 1999. [6] Parviz Soroushian and Ziad Bayasi, Fiber- Type Effects on the Performance of Steel Fiber Reinforced Concrete, ACI materials journal, Vol 88, No. 2, March-April 1991. [7] Sawant R.M., Khan Jabeen, Aher Minal, Bundele Akash, Comprehensive Study of High Strength Fiber Reinforced Concrete Under Pull Out Strength, International Journal Of Civil Engineering And Technology, volume 6, Issue 1, January 2015, PP:14-20. [8] Sawant R.M., Khan Junaid, Khan Jabeen, Waykar Satish, Behavior Of High Strength Fiber Reinforced Concrete Under Shear International Journal Of Civil Engineering And Technology, volume 6, Issue 4, April 2015, PP:46-54. [9] ASTM A 820 type-i Standard Specification for Steel Fibers for Fiber-Reinforced Concrete, American Society for Testing and Materials, west Conshohocken, Pennsylvania [10] Syambabu Nutalapati, Dr. D. Azad and Dr. G. Swami Naidu, Effect of Welding Current on Welding Speed and Ultimate Tensile Strength (UTS) of Mild Steel. International Journal of Mechanical Engineering and Technology, 7(5), 2016, pp. 156 176. [11] J. Santhakumar, U.Mohammed Iqbal and M.Prakash, Investigation on the Effect of Tensile Strength on Fdm Build Parts Using Taguchi-Grey Relational Based Multi- Response Optimization, International Journal of Mechanical Engineering and Technology 8(12), 2017, pp. 53 60. http://www.iaeme.com/ijciet/index.asp 1671 editor@iaeme.com