E-FT-5, E-FT-6 & FFT4

Similar documents
Part E robustdetails. robustdetails. January 2017 Update Pack. Dear Colleague,

Acoustic Cradle Levelling System

Part E robustdetails. robustdetails. January 2018 Update Pack

September Saddle Flooring Systems

ROCKWOOL FLEXI Insulation Application Guide

ACOUSTIC SUPPLIES. For Acoustic Solutions you can SHOUT about

SOUND SOLUTIONS TO MEET THE APPROVED DOCUMENT E (2003 EDITION) August 2008

Most products will act differently when installed over an UFH system than when installed on a standard unheated subfloor.

E-Cousti Solutions Guide

Underfloor Heating System

Jabfloor 70, 100, 150, 200, 250

FIRE PROTECTION. GTEC Shaftwall systems 244 GTEC Shaftwall Stairwell systems 248 GTEC Horizontal Shaftwall systems 249 GTEC Encasement systems 250

Garage Conversion - Between and Under Joist Applications

Specialists in Acoustic Flooring and House to Flat Conversions

June Residential Refurbishment Exposed soffit floors

June Residential Refurbishment Separating walls

Floating Floor Constructions

Loadbearing timber joist floors

GypLyner. GypLyner. Metal framed wall lining system. All our systems are covered by SpecSure when using genuine Gyproc and Isover products.

SOUND INSULATION TESTING IN DWELLINGS

URSA MINERAL WOOL URSA Acoustic Roll

An introduction to Part L U-values

GypLyner UNIVERSAL Metal framed wall lining system

GypLyner UNIVERSAL Metal framed wall lining system

The extra strong, extra durable, sound resistant system that you can direct fix to

C05. S03. P02 P08 FireWall

F L O O R S A N D C E I L I N G S

C04. S05. P02 P14 GypWall quiet sf

This page was. intentionally. left blank

Staggered stud acoustic partition system

Part E robustdetails. robustdetails. April 2017 Update Pack. Dear Colleague,

Xtratherm Thin-R Thermal Liner (XT/TL Grade)

Thermal Laminate Board.

Acoustic Detailing For Steel Construction

The Passive Fire Protection Handbook

MONARFLOOR ACOUSTIC SYSTEMS MONAFLOOR 9, 18 AND 22 ACOUSTIC DECK SYSTEMS

SECTION D Masonry Wall Systems. Contents. Introduction. Design Considerations. Installation. Components. System Specifications.

Floors Walls Roofs. Jabfloor Premium board Jablite Premium board Jabfloor board Jablite board. APPLICATION: Basements PRODUCTS: Vencel Resil Limited

URSA MINERAL WOOL URSA Timber Frame Roll & URSA Timber Frame Slab

Floors Walls Roofs. Jabroll. APPLICATION: Flat and Curved Roofs PRODUCTS: Vencel Resil Limited

June Non - Residential Refurbishment Internal lining walls

Section 11 FIRE STOPPING

Bavaria. PowerFloor. PhoneStar. SYSTEM SOLUT ions FOR TIMBER FRAME HOUSES AND REFURBISHMENTS DRY SCREED UNDERFLOOR HEATING SOUND INSULATION

TILING SPECIFICATIONS

The ultimate free-flowing floor screed

GenieMat FF. Floating Floor Systems for Airborne & Impact Sound and Vibration Isolation. It s not magic, it s engineering. Impact Sound Control

BBA 001 Documents included under the scope of BBA s ISO UKAS accreditation

EcoHome-Insulation.com. Aluminium Foil Bubble Insulation. General Purpose Insulation. Dry Lining. Cavity Wall. Insulation System.


June Residential Refurbishment Basements

Part E robustdetails. robustdetails. September 2017 Update Pack. Dear Colleague,

OS Thermal System Installation Guide


SINTEF Building and Infrastructure confirms that. Separating floors with Hunton Silencio 36 / Hunton Silencio Thermo

FIRESTOP JOINT SPRAY CFS-SP WB. 2mm (0.079") WET FILM ± 7.5 ± 5

SoundPro CDM-ISO-LAT. Acoustic solution for floating isolated floors

Cavity fire barriers. Cavity fire barriers. Fire separation within concealed spaces. C06 Floors and ceilings

BEAM & BLOCK SYSTEM. 108mm. 175mm Deep (160mm) Wide Beam. 160mm

June Residential New Build Timber Frame Walls

Benefits.

T-Barrier System. Masonry Applications. Satisfying Fire, Thermal and Acoustic Requirements at the Combined Party Wall and Pitched Roof Junction

CERTIFICATE OF APPROVAL No CF 517 FSI LIMITED

CasoLine MF Concealed grid MF suspended ceiling system

Section Sound Control

Tiling Tiling Finishes C08

Separating walls. Countryside Properties, Lock 38, Stoke-on-Trent

Construction Technology Revision Guide

CasoLine MF Concealed grid MF suspended ceiling system

Schluter -KERDI-BOARD Substrate, building panel, bonded waterproofing

Civil Engineering Construction Chapter 5

Dow Building Solutions Insulating lightweight inverted roofs with STYROFOAM Solutions

Tehnical Data Sheet Astro Intu Mastic. UIC of product-type: INTUM CPR-JA5015

THERMAL LAMINATES. for roofs, walls, floors and soffits

energy saving for the future

Ceiling Attenuation Class Systems SYSTEMS 280

Acoustic Testing of CLT and Glulam Floor Assemblies Nordic Engineered Wood Report No. A August 2016 CONSTRUCTION

Day Night Day Night Day Night Residential site and amphitheatre Green Non residential site boundary Red

Floors Walls Roofs. Jablite Premium board Jablite board. APPLICATION: Internally Lined Pitched Roof PRODUCTS: Vencel Resil Limited

SUBSTRATES FOR WOOD FLOOR SETTING

FIRE PROTECTION AND PERFORMANCE DRY LINING BOARD THE ULTIMATE IN FIRE PROTECTION! 91 mins fire integrity and 86 mins fire insulation on 9mm board

SECTION E Ceiling Systems. Contents. Introduction. Design Considerations. Installation. Components. System Specifications. Floor/Ceiling Systems

TW50. Insulation STANDARD DETAILS FOR 50 MM INSULATION BOARD IN A 100 MM CAVITY. Low Energy Low Carbon Buildings. Wall lining. Inner leaf blockwork

URSA MINERAL WOOL URSA Cavity Batts

External Steel Stud and Top Hat Walls. Details SYSTEMS 176 NON-FIRE RATED SYSTEMS 176 FIRE RATED SYSTEMS 178 BRICK VENEER SYSTEMS 183 INSTALLATION 185

PLYWOOD FLOATING FLOOR

Aircrete blocks product guide

Structural Products. Multideck 50-V3 Galvanised Steel Floor Decking System

C05. S02. P02 P30 ShaftWall

04 ENCLOSURE 0472p CSR BRADFORD in acoustic insulation

84 Lapping & Jointing 86 Service Pipe Penetrations 87 Sealing to Cavity Wall Constructions 88 Protecting Membranes System Components.

DIVISION: FINISHES SECTION: ACOUSTIC TREATMENT REPORT HOLDER: ECORE INTERNATIONAL, INC.

The better way to build TM. Installation Manual FOUNDATION SIPs & FROST WALLS SIPs

HOLLOW CORE FLOORS SPEED AND STRENGTH

Technical Data Sheet. Astro HPE Sealant. UIC of product-type: AFHPE

1. The subfloor must be structurally sound and able to withstand live and dead loads with a deflection limitation of L/360.

BISON PRECAST FLOORING SPECIFICATION

FIRESTOP AND FIRE PROTECTION

Promat PROMASEAL Fire Barrier

Thermablok Aerogel Isolation Strips Thermablok Aerogel Isolation Strips

HP Partial Fill. Robust, long-lasting protection

Transcription:

CI/SfB (.9) n7 (M) March 01 ScreedBoard The Ultimate Floor Board for Sound and Underfloor Heating obust detail Acoustic Treatment E-FT-5 & E-FT-6 Excellent acoustic performance on all floor types Maximises the efficiency of underfloor heating systems obust detail E-FT-5, E-FT-6 & FFT4 Compliant Cellecta I N N O V A T I O N I N I N S U L A T I O N E V D I D F I BBA A E T D A THE CODE FO SUSTAINABLE HOMES NHBC Accepted NO SCEWS PAT E Solution

Cellecta I N N O V A T I O N I N I N S U L A T I O N ScreedBoard The ultimate floor board... Videos News New Build efurb More Cellecta ScreedBoard The ultimate overlay board for acoustic and underfloor heating applications ScreedBoard s are manufactured from recycled calcium sulphate and reinforced with cellulose fibres. The boards have a very high density, high impact resistance, hard wearing surface and interlocking edges making them ideal for acoustic and underfloor heating applications. ScreedBoard8 ScreedBoard 8 is the ultimate single layer acoustic overlay treatment, featuring interlocking edges for installation convenience. Its high density and unique resilient layer provides unrivalled acoustic performance. ScreedBoard 8 is the only single layer system to carry obust detail status ( E-FT-5 & 6). ScreedBoard 8 Applications Mat 1 Pol 1 Hea 1 Mat 1 Pol 1 Hea 1 Pol 1 Hea 1 Timber I-Joist Separating Floors obust detail E-FT-5 Metal-Web Separating Floors obust detail E-FT-6 Metal Joist Separating Floors PCT Solution PHYSICAL POPETIES Properties esilient layer / slab composition Type and thickness of facing/batten esilient layer thickness Overall thickness Board size / roll size / slab size Weight Long term water absorption (esilient layer) Unit - - mm mm m kg/m kg/ roll/board %_ vol. ScreedBoard 0 N/A 0mm HD Gypsum N/A 0 0.6 x 1.0 5.00 8 ecycled PES fibre board 0mm HD Gypsum 8 8 0.6 x 1.0 6.00 18.00 18.7 - - Benefits of ScreedBoard 8 (1) (1) High acoustic performance: Airborne 51dB and Impact 55dB obust detail system E-FT-5 & 6 and FFT4 compliant Code credits available: Mat 1, Pol 1 & Hea Only 8mm thick Doesn't contract or expand like chipboard when exposed to water High impact resistance Interconnecting edge detail - no screws required educes the number of brick courses required Quick and easy to install Can be cut with a hand or skill saw Accepts ceramic tiles Weighs only 18.7kg per sheet (1) Typical performance of E-FT-5. *Code credits are subject to appropriate weighting. NO SCEWS Global warming potential (GWP) 0 0 (1) Note Percentage of water absorption after 8 days fully E V I F I BBA E D A D D A T obust detail Acoustic Treatment Cellecta App

ScreedBoard 0 ScreedBoard 0 Applications Pol 1 1 Mat 1 Hea Cellecta ScreedBoard 0is the ideal product for floors featuring an underfloor heating system due to its low thermal resistance and rapid heat transfer characteristics. ScreedBoard 0is also suitable for acoustic flooring applications incorporating an underfloor heating system, when combined with FIBEfon 8. Pol 1 Hea 1 Pol 1 Hea 1 Timber Joist Separating Floors with Under Floor Heating System obust detail E-FT-5 & 6 Benefits of ScreedBoard 0 Low thermal resistance (0.05m /kw) Metal Joist Separating Floors with Under Floor Heating system Ideal for underfloor heating systems () (1) (1) High acoustic performance : Airborne 51dB and Impact 55dB obust detail treatment - E-FT-5 & 6 (when used with FIBEfon8) Code credits available: Mat 1, Pol 1 & Hea Only 0mm thick Doesn't contract or expand like chipboard when exposed to water High impact resistance Interconnecting edge detail - no screws required Quick and easy to install Accepts ceramic tiles Weighs only 18.00kg per sheet (1) () Typical performance of E-FT-5. When used in conjunction with FIBEfon8 resilient sheets. NO SCEWS Ground Floors with Under Floor Heating System THEMAL ESISTANCE ScreedBoard 0 has the lowest thermal resistance when compared to the most commonly used floor finishes, allowing ground water heat pumps and heat recovery systems to work at maximum efficiency. Intensity of heat flow obust detail FFT1 m /kw 0.7 ScreedBoard 0 m /kw 0.05 18mm Chipboard m /kw 0.18 ScreedBoard 0 m /kw 0.05 75mm Screed m /kw 0.065 Thermal and acoustic applcations Thermal applications

Videos News New Build efurb More Design & installation details - Cellecta ScreedBoard 8 The acoustic performance of the floor structure will be compromised if the ScreedBoard s are not completely isolated from the timber sub-floor, soil pipes, door frames, surrounding walls and their treatments. To address this risk, each potential problem area needs to be detailed accordingly. 7 6 8 Cellecta I N N O V A T I O N I N I N S U L A T I O N ScreedBoard The ultimate floor board... Installation video on the Cellecta app 5 4 YELOfon FS strip MUST be placed around floor perimeter, including around all walls that are built off the structural floor 1 9 Stairwell/ communal area A D B C E E Fixing tools A. Club hammer B. Hand or skill saw C. ScreedBoard Pull bar D. ScreedBoard Fixing batten E. ScreedBoard SB adhesive Packing shims (not shown) 1 Door threshold Metal frame partition built off the floor treatment Timber stud partition built off the floor treatment Stairwell/ communal area rd w + C tr = 14dB Leave a 5-10mm expansion gap between the habitable area and the communal area ScreedBoards. rd w+ C tr = 14dB Non-load bearing metal frame or timber stud walls can be built directly off the ScreedBoard 8. Care should be taken to ensure screws DO NOT penetrate the resilient layer. 4 Baths, shower trays and sanitary ware built off floor treatment. 5 6 Baths, shower trays and sanitary ware built off the structural floor Metal frame partition built off the structural floor Baths, shower trays and sanitary ware can be built directly off the ScreedBoard 8. Under no circumstance should screws penetrate the resilient layer. Baths. shower trays and sanitary ware built off the structural floor should be isolated from the ScreedBoard 8 and any floor finished. Lightweight partition walls built off the structural floor MUST be isolated from the ScreedBoard with YELOfon FS50 strip. 7 Wall treatment installed before the ScreedBoard 8 8 9 Wall treatment installed after the ScreedBoard 8 Timber stud partition built off the structural floor 4 Wall treatments MUST be isolated from the ScreedBoard 8 with YELOfon FS50 strip. Wall treatments MUST be isolated from the ScreedBoard 8 with YELOfon FS50 strip. Lightweight Internal walls built off the structural floor MUST be isolated from the ScreedBoard with YELOfon FS strip.

Timber Separating Floors Introduction By nature, timber floors are low in mass, making them more susceptible to poor acoustic performance and therefore more challenging to ensure compliance. ScreedBoard will add mass and dramatically reduce impact sound transmission at source. The addition of plasterboards, a dry screed board or proprietary screed will add further mass. esilient ceiling bars will de-couple the ceiling and a fibrous slab or quilt will absorb sound in the ceiling void. When correctly installed with a perimeter flanking strip the system will exceed the legislative acoustic standards. Cellecta efurbishment & Conversion Projects Existing timber floors typically have a low mass and sometimes unknown construction details, making them inherently difficult to achieve the prescribed acoustic values without addressing a number of areas. The floor s mass can be increased by the introduction of additional plasterboard layers. Cellecta FIBEfon Micro 50 or mineral wool placed in the ceiling void will defuse airborne sound. esilient bars will de-couple the ceiling, and ScreedBoard can reduce the impact sound at source. Historical Buildings With some historical buildings undergoing a material change of use, it may not be practical to achieve the prescribed sound values. In these cases, Building Control bodies should be satisfied that everything reasonable has been done to improve the sound performance of the structure. Pre-completion tests are normally required and the results submitted accordingly. FEATUED POJECT POJECT NAME Apartments, Caddington oad, Luton PODUCT INSTALLED ScreedBoard 8 POJECT SIZE 5,500m² TYPE OF CONSTUCTION Timber Frame obust Detail E-FT-5 POJECT COMPLETION July 01 d Compliant Treatment E-FT-5 For other projects please visit 5

Structural separating floor - Timber obust detail E-FT-5 Cellecta ScreedBoard 8 laid on timber sub-floor Timber I-joists Use with timber frame walls only Floating floor treatment Floor decking Joists Absorbing material Ceiling (1) 18mm(min) required for obust detail applications Cellecta ScreedBoard 8 (See Table TF4 for full details) (1) 15 mm thick (min) wood based board, density 600kg/m (min) 40mm (min) timber I-joists 100mm (min) quilt insulation (10-6kg/m ) between joists See Table TF4 for ceiling treatment Fig. TF4 FASTACKCAD ACHITECTUAL CAD DATABASES Table TF4 obust detail Detail E-FT-5 E-FT-1 floating compliant floor floating treatment floor treatment Perimeter resilient flanking strip required Ceiling treatment ScreedBoard 8 High density composite resilient overlay treatment Additional layers required to complete treatment Mineral wool quilt laid between joists - 100mm (min) 10-kg/m No need for screws Interlocking edges glued together with Cellecta SB joint adhesive Product information Board dimensions: 8mm x 600mm x 100mm Edge profile: Interlocking tongue & groove Weight: 6.00kg/m / 18.7kg per board Cellecta SB joint adhesive: 1L to every m of boards obust Detail mean performance D nt,w + C tr = 51dB L nt,w = 55dB Typical PCT () performance D nt,w + C tr = 51dB L nt,w = 55dB Benefits of ScreedBoard 8 over an acoustic batten system (FFT1) Grey dry screed finish Only 8mm thick educes number of brick courses required Able to accept ceramic tiles Only one component to install (+ edge strip) Interlocking edge detail - no screws req d Weighs only 18.7kg per board (0.7m ) Weighs less per/m than FFT1 treatment No need to employ a specialist contractor Quick and easy to install Pol 1 1 Mat 1 107mm 8mm Hea YELOfon FS50 Pre-formed polyethylene foam flanking angle: 6 mm x 50mm x 0mm x m installed around the perimeter of the flooring board to isolate floor from walls and skirting. 40mm (min) Ceiling board fixings must not penetrate or touch the floor joists 16mm (min) metal resilient bars mounted at right angles to the joist at 400mm centres. Primary ceiling: CT1-Two layers of gypsum-based board, composed of 19mm (nominal 1.5kg/m ) fixed with mm screws and 1.5mm (nominal 10kg/m ) fixed with 4mm screws, with all joists staggered. CT -Two layers of gypsum-based board, composed of 15mm (nominal 1.5kg/m ) fixed with 5mm screws and a second layer of 15mm (nominal 1.5kg/m ) fixed with 4mm screws, with all joists staggered. Sacrificial ceiling: Metal ceiling system with a 150mm (min) void fixed to underside of primary ceiling. One layer of nominal 8kg/m gypsum based board. 150mm (min) Service void Construction notes Services must not puncture primary ceiling lining (except cables, which should be sealed with flexible sealant) * Code for Sustainable Homes (CSH) credits quoted are typical. Mat 1 value taken from the BE Green Guide. Pol 1 credit is only awarded if all the other insulation products used have a GWP of <5. Hea credits are based on the floor being pre-completetion tested and the separating wall performing to at least the same acoustic standard. Credits subject to relevant category weighted value. See page 5 for further information. Acoustic values () Values quoted are typical, based on the treatment being installed correctly and pre-completion tested. Airborne performance tested in accordance with BS EN ISO 140-4:1998 Impact performance tested in accordance with BS EN ISO 140-7: 1998 6

Structural separating floor - Timber Joists Absorbing material Ceiling (1) 18mm(min) required for obust detail applications obust detail E-FT-5 Cellecta ScreedBoard 0 laid on underfloor heating system Cellecta FIBEfon 8 acoustic layer laid on timber sub-deck Timber I-joists and timber frame walls only Floating floor treatment UFH thermal insulation Acoustic layer Floor decking Cellecta ScreedBoard0 (See Table TF5 for full details) 1mm (min) routed extruded or routed/moulded expanded polystyrene insulation Cellecta FIBEfon 8 (1) 15 mm thick (min) wood based board, density 600kg/m (min) 40mm (min) timber I-joists 100mm (min) quilt insulation (10-6kg/m ) between joists See Table TF5 for ceiling treatment Fig. TF5 Table TF5 obust detail Detail E-FT-5 E-FT-1 floating compliant floor floating treatment floor treatment FASTACKCAD ACHITECTUAL CAD DATABASES Perimeter resilient flanking strip required Ceiling treatment ScreedBoard 0 High density thermally conductive floor board Option 1: Underfloor heating thermal board XFLOO 50 High performance extruded polystyrene boards Option : outed or moulded expanded polystyrene (EPS) panel FIBE fon 8 ecycled resilient layer NO SCEWS YELOfon FS50 Pre-formed polyethylene foam flanking angle: 6 mm x 50mm x 0mm x m installed around the perimeter of the flooring board to isolate floor from walls and skirting. Ceiling board fixings must not penetrate or touch the floor joists 16mm (min) metal resilient bars mounted at right angles to the joist at 400mm centres. Primary ceiling: CT1-Two layers of gypsum-based board, composed of 19mm (nominal 1.5kg/m ) fixed with mm screws and 1.5mm (nominal 10kg/m ) fixed with 4mm screws, with all joists staggered. CT-Two layers of gypsum-based board, composed of 15mm (nominal 1.5kg/m ) fixed with 5mm screws and a second layer of 15mm (nominal 1.5kg/m ) fixed with 4mm screws, with all joists staggered. Additional layers required to complete treatment Mineral wool quilt laid between joists - 100mm (min) 10-kg/m Sacrificial ceiling: Metal ceiling system with a 100mm (min) void fixed to underside of primary ceiling. One layer of nominal 8kg/m gypsum based board. Product information ScreedBoard 0 Board dimensions: 0mm x 600mm x 100mm Edge profile: Interlocking tongue & groove Weight: 5.00kg/m / 18.00kg per board Thermal resistance: 0.40m K/W FIBEfon 8 acoustic fleece; 8mm x 600mm x 100mm Cellecta SB joint adhesive: 1L for every m of boards obust Detail mean performance D nt,w + C tr = 51dB L nt,w = 55dB Typical PCT () performance D nt,w + C tr = 51dB L nt,w = 55dB Pol 1 1 Mat 1 Hea 40mm (min) 150mm (min) Service void Construction notes Materials must be installed in accordance with manufacturers instructions to achieve stated acoustic values. Wall treatments MUST be isolated from the floating floor with YELOfon FS50 flanking strip. Ensure services do not bridge the resilient layer. Services must not puncture primary ceiling lining (except cables, which should be sealed with flexible sealant). * Code for Sustainable Homes (CSH) credits quoted are typical. Mat 1 value taken from the BE Green Guide. Pol 1 credit is only awarded if all the other insulation products used have a GWP of <5. Hea credits are based on the floor being pre-completetion tested and the separating wall performing to at least the same acoustic standard. Credits subject to relevant category weighted value. Acoustic values () Values quoted are typical, based on the treatment being installed correctly and pre-completion tested. Airborne performance tested in accordance with BS EN ISO 140-4:1998 Impact performance tested in accordance with BS EN ISO 140-7: 1998 7

Structural separating floor - Timber obust detail E-FT-6 Cellecta ScreedBoard 8 laid on timber sub-floor MiTeK Posi-Joist, Prestaplan Presweb metal web joists Use with timber frame walls only Floating floor treatment Floor decking Cell ecta ScreedBoard 8 (See Table TF6 for full details) (1) 15 mm thick (min) wood based board, density 600kg/m (min) Joists Absorbing material Ceiling 5mm (min) Posi-Joist, PresWeb () metal web joists 100mm (min) quilt insulation (10-6kg/m ) between joists See Table TF6 for ceiling treatment (1) 18mm(min) required for obust detail applications ( ) Alternative joist may be used but will be subject to pre-completion testing Fig. TF6 FASTACKCAD ACHITECTUAL CAD DATABASES Table TF6 obust detail E-FT-6 floating floor treatment Perimeter resilient flanking strip required Ceiling treatment ScreedBoard 8 High density composite resilient overlay treatment Additional layers required to complete treatment Mineral wool quilt laid between joists - 100mm (min) 10-kg/m No need for screws Interlocking edges glued together with Cellecta SB joint adhesive Product information Board dimensions: 8mm x 600mm x 100mm Edge profile: Interlocking tongue & groove Weight: 6.00kg/m / 18.7kg per board Cellecta SB joint adhesive: 1L for every m of boards obust Detail mean performance D nt,w + C tr = 5dB L nt,w = 55dB Typical PCT () performance D nt,w + C tr = 5dB L nt,w = 55dB Benefits of ScreedBoard 8 over an acoustic batten system (FFT1) Grey dry screed finish Only 8mm thick educes number of brick courses required Able to accept ceramic tiles Only one component to install (+ edge strip) Interconnecting edge detail - no screws req d Weighs only 18.7kg per board (0.7m ) Same weight/m as FFT1 treatment No need to employ a specialist contractor Quick and easy to install Pol 1 1 Mat 1 107mm 8mm Hea YELOfon FS50 Pre-formed polyethylene foam flanking angle: 6mm x 50mm x 0mm x m placed around the perimeter of the flooring board to isolate floor from walls and skirting. 5mm (min) Ceiling board fixings must not penetrate or touch the floor joists 16mm (min) metal resilient bars mounted at right angles to the joist at 400mm centres. Primary ceiling: CT1-Two layers of gypsum-based board, composed of 19mm (nominal 1.5kg/m ) fixed with mm screws and 1.5mm (nominal 10kg/m ) fixed with 4mm screws, with all joists staggered. CT -Two layers of gypsum-based board, composed of 15mm (nominal 1.5kg/m ) fixed with 5mm screws and a second layer of 15mm (nominal 1.5kg/m ) fixed with 4mm screws, with all joists staggered. Sacrificial ceiling: Metal ceiling system with a 150mm (min) void fixed to underside of primary ceiling. One layer of nominal 8kg/m gypsum based board. 100mm (min) Service void Construction notes Services must not puncture primary ceiling lining (except cables, which should be sealed with flexible sealant). * Code for Sustainable Homes (CSH) credits quoted are typical. Mat 1 value taken from the BE Green Guide. Pol 1 credit is only awarded if all the other insulation products used have a GWP of <5. Hea credits are based on the floor being pre-completetion tested and the separating wall performing to at least the same acoustic standard. Credits subject to relevant category weighted value. See page 5 for further information. Acoustic values () Values quoted are typical, based on the treatment being installed correctly and pre-completion tested. Airborne performance tested in accordance with BS EN ISO 140-4:1998 Impact performance tested in accordance with BS EN ISO 140-7: 1998 8

Structural separating floor - Timber Cell ecta ScreedBoard 0 laid on underfloor heating system Cell ecta FIBEfon 8 laid acoustic layer laid on timber sub-deck MiTeK Posi-Joist, Prestaplan Presweb metal-web joists and timber frame walls only Floating floor treatment Floor decking Joists Absorbing material Ceiling obust detail E-FT-6 Cellecta ScreedBoard 0 (See Table TF7 for full details) Under floor heating 1mm (min) routed extruded or thermal insulation routed/moulded expanded polystyrene insulation Acoustic layer Cellecta FIBEfon 8 (1) 15 mm thick (min) wood based board, density 600kg/m (min) 5mm (min) Posi-Joist, PresWeb () metal web joists 100mm (min) quilt insulation (10-6kg/m ) between joists See Table TF7 for ceiling treatment (1) 18mm(min) required for obust detail applications ( ) Alternative joist may be used but will be subject to pre-completion testing Fig. TF7 Table TF7 obust detail Detail E-FT-6 E-FT-1 floating compliant floor floating treatment floor treatment Perimeter resilient flanking strip required Ceiling treatment ScreedBoard 0 High density thermally conductive floor board Option 1: Underfloor heating thermal board Cellecta XFLOO 50 Option : outed or moulded expanded polystyrene (EPS) panel FIBE fon 8 ecycled resilient layer High performance extruded polystyrene boards NO SCEWS YELOfon FS50 Pre-formed polyethylene foam flanking angle: 6 mm x 50mm x 0mm x m installed around the perimeter of the flooring board to isolate floor from walls and skirting. Ceiling board fixings must not penetrate or touch the floor joists 16mm (min) metal resilient bars mounted at right angles to the joist at 400mm centres. Primary ceiling: CT1-Two layers of gypsum-based board, composed of 19mm (nominal 1.5kg/m ) fixed with mm screws and 1.5mm (nominal 10kg/m ) fixed with 4mm screws, with all joists staggered. CT -Two layers of gypsum-based board, composed of 15mm (nominal 1.5kg/m ) fixed with 5mm screws and a second layer of 15mm (nominal 1.5kg/m ) fixed with 4mm screws, with all joists staggered. Additional layers required to complete treatment Mineral wool quilt laid between joists - 100mm (min) 10-kg/m ScreedBoards interlocking edges glued together with Cellecta SB adhesive Sacrificial ceiling: Metal ceiling system with a 150mm (min) void fixed to underside of primary ceiling. One layer of nominal 8kg/m gypsum based board. Product information ScreedBoard 0 Board dimensions: 0mm x 600mm x 100mm Edge profile: Interlocking tongue & groove Weight: 5.00kg/m / 18.00kg per board Thermal resistance: 0.40m K/W FIBEfon 8 acoustic fleece; 8mm x 600mm x 100mm Cellecta SB joint adhesive: 1L for every m of boards obust Detail mean performance D nt,w + C tr = 5dB L nt,w = 55dB Typical PCT () performance Pol 1 1 Mat 1 Hea 5mm (min) D nt,w + C tr = 5dB L nt,w = 55dB 100mm (min) Service void Construction notes Materials must be installed in accordance with manufacturers instructions to achieve stated acoustic values. Wall treatments MUST be isolated from the floating floor with YELOfon FS50 flanking strip. Ensure services do not bridge the resilient layer. Services must not puncture primary ceiling lining (except cables, which should be sealed with flexible sealant). * Code for Sustainable Homes (CSH) credits quoted are typical. Mat 1 value taken from the BE Green Guide. Pol 1 credit is only awarded if all the other insulation products used have a GWP of <5. Hea credits are based on the floor being pre-completetion tested and the separating wall performing to at least the same acoustic standard. Credits subject to relevant category weighted value. Acoustic values () Values quoted are typical, based on the treatment being installed correctly and pre-completion tested. Airborne performance tested in accordance with BS EN ISO 140-4:1998 Impact performance tested in accordance with BS EN ISO 140-7: 1998 9

Structural separating floor - Timber PCT solution Cellecta ScreedBoard 8 laid on timber sub-floor Solid timber joists Use with timber frame walls only Floating floor treatment Floor decking Joists Absorbing material Ceiling Cellecta ScreedBoard 8 (See Table TF8 for full details) 15mm thick (min) OSB 0mm (min) solid timber joists 100mm (min) quilt insulation (10-6kg/m ) between joists See Table TF8 for ceiling treatment Fig. TF8 FASTACKCAD ACHITECTUAL CAD DATABASES Table TF8 PCT obust floating Detail floor E-FT-1 treatment compliant floating floor treatment Perimeter resilient flanking strip required Ceiling treatment ScreedBoard 8 High density composite resilient overlay treatment Additional layers required to complete treatment Mineral wool quilt laid between joists - 100mm (min) 10-kg/m No need for screws Interlocking edges glued together with Cellecta SB joint adhesive Product information Board dimensions: 8mm) x 600mm x 100mm Edge profile: Interlocking tongue & groove Weight: 6.00kg/m / 18.7kg per board Cellecta SB joint adhesive: 1L for every m of boards Typical PCT () performance D nt,w + C tr = 50dB L nt,w = 50dB Benefits of ScreedBoard 8 over an acoustic batten system (FFT1) Grey dry screed finish Only 8mm thick educes number of brick courses required Able to accept ceramic tiles Only one component to install (+ edge strip) Interconnecting edge detail - no screws req d Weighs only 18.7kg per board (0.7m ) Same weight/m as FFT1 treatment No need to employ a specialist contractor Quick and easy to install 107mm 8mm Pol 1 1 Mat 1 Hea YELOfon FS50 Pre-formed polyethylene foam flanking angle: 6mm x 50mm x 0mm x m placed around the perimeter of the flooring board to isolate floor from walls and skirting. 0mm (min) Ceiling board fixings must not penetrate or touch the floor joists 16mm (min) metal resilient bars mounted at right angles to the joist at 400mm centres. Primary ceiling: CT1-Two layers of gypsum-based board, composed of 19mm (nominal 1.5kg/m ) fixed with mm screws and 1.5mm (nominal 10kg/m ) fixed with 4mm screws, with all joists staggered. CT-Two layers of gypsum-based board, composed of 15mm (nominal 1.5kg/m ) fixed with 5mm screws and a second layer of 15mm (nominal 1.5kg/m ) fixed with 4mm screws, with all joists staggered. Sacrificial ceiling: Metal ceiling system with a 100mm (min) void fixed to underside of primary ceiling. One layer of nominal 8kg/m gypsum based board. 100mm (min) Service void * Code for Sustainable Homes (CSH) credits quoted are typical. Mat 1 value taken from the BE Green Guide. Pol 1 credit is only awarded if all the other insulation products used have a GWP of <5. Hea credits are based on the floor being pre-completetion tested and the separating wall performing to at least the same acoustic standard. Credits subject to relevant category weighted value. See page 5 for further information. Acoustic values () Values quoted are typical, based on the treatment being installed correctly and pre-completion tested. Airborne performance tested in accordance with BS EN ISO 140-4:1998 Impact performance tested in accordance with BS EN ISO 140-7: 1998 10

Structural separating floor - Timber PCT solution Cellecta ScreedBoard 0 laid on underfloor heating system Solid timber joists Use with timber frame walls only Floor finish Under floor heating thermal insulation Acoustic layer Floor decking Joists Absorbing material Ceiling Cellecta ScreedBoard 0 (See Table TF9 for full details) 1mm (min) routed extruded or routed/moulded expanded polystyrene insulation bonded to Cellecta FIBEfon 8 resilient layer 15mm thick (min) OSB 0mm (min) solid timber joist 100mm (min) quilt insulation (10-6kg/m ) between joists See Table TF9 for ceiling treatment Fig. TF9 FASTACKCAD ACHITECTUAL CAD DATABASES Table TF9 PCT obust floating Detail floor E-FT-1 treatment compliant floating floor treatment Perimeter resilient flanking strip required Ceiling treatment options ScreedBoard 0 High density low resistance floor board Option 1: Underfloor heating thermal board XFLOO 50 High performance extruded polystyrene boards Option : outed or moulded expanded polystyrene (EPS) panel FIBE fon 8 ecycled resilient layer NO SCEWS YELOfon ES5/10 Polyethylene foam flanking strip: 5mm x 10mm x 50m installed around the perimeter of the flooring board to isolate floor from walls and skirting. Ceiling board fixings must not penetrate or touch the floor joists 16mm (min) metal resilient bars mounted at right angles to the joist at 400mm centres. Primary ceiling: CT1-Two layers of gypsum-based board, composed of 19mm (nominal 1.5kg/m ) fixed with mm screws and 1.5mm (nominal 10kg/m ) fixed with 4mm screws, with all joists staggered. CT-Two layers of gypsum-based board, composed of 15mm (nominal 1.5kg/m ) fixed with 5mm screws and a second layer of 15mm (nominal 1.5kg/m ) fixed with 4mm screws, with all joists staggered. Additional layers required to complete treatment Mineral wool quilt laid between joists - 100mm (min) 10-kg/m ScreedBoards glued together with Cellecta SB joint adhesive Sacrificial ceiling: Metal ceiling system with a 100mm (min) void fixed to underside of primary ceiling. One layer of nominal 8kg/m gypsum based board. Product information ScreedBoard 0 Board dimensions: 0mm x 600mm x 100mm Edge profile: Interlocking tongue & groove Weight: 5.00kg/m / 18.00kg per board Thermal resistance: 0.0m K/W FIBEfon 8 acoustic fleece; 8mm Cellecta SB joint adhesive: 1L for every m of boards XFLOO 50: see page 60 for further information EPS: refer to manufacturers technical data obust Detail mean performance D nt,w + C tr = 51dB L nt,w = 55dB Typical PCT () performance D nt,w + C tr = 51dB L nt,w = 55dB Pol 1 1 Mat 1 Hea 0mm (min) 100mm (min) Service void Construction notes Materials must be installed in accordance with manufacturers instructions to achieve stated acoustic values. Wall treatments MUST be isolated from the floating floor with YELOfon ES5/10 flanking strip. Ensure services do not bridge the resilient layer. Services must not puncture primary ceiling lining (except cables, which should be sealed with flexible sealant). * Code for Sustainable Homes (CSH) credits quoted are typical. Mat 1 value taken from the BE Green Guide. Pol 1 credit is only awarded if all the other insulation products used have a GWP of <5. Hea credits are based on the floor being pre-completetion tested and the separating wall performing to at least the same acoustic standard. Credits subject to relevant category weighted value. See page 5 for further information. Acoustic values () Values quoted are typical, based on the treatment being installed correctly and pre-completion tested. Airborne performance tested in accordance with BS EN ISO 140-4:1998 Impact performance tested in accordance with BS EN ISO 140-7: 1998 11

Structural separating floor - Timber PCT solution Cell ecta ScreedBoard 8 laid on timber sub-floor Timber I-joists, solid timber, metal web or timber web joists Use with timber frame walls only Floating floor treatment Floor decking Joists Absorbing material esilient bar Ceiling Cellecta ScreedBoard 8 (See Table TF10 for full details) 15mm thick (min) wood based board, density 600kg/m (min) 0mm (min) solid timber joist 40mm (min) timber I-joists 5mm (min) metal web joists 54mm (min) timber web joists 100mm (min) quilt insulation (10-6kg/m ) between joists Cellecta HP0 deep resilient bar fixed to timber joists at 600mm (max) centres (See Table TF10 for full details). Table TF10 PCT obust floating Detail floor E-FT-1 treatment compliant floating floor treatment FASTACKCAD ACHITECTUAL CAD DATABASES Perimeter resilient flanking strip required Ceiling treatment options ScreedBoard 8 High density composite resilient overlay treatment Additional layers required to complete treatment Mineral wool quilt laid between joists - 100mm (min) 10-kg/m No need for screws Interlocking edges glued together with Cellecta SB joint adhesive YELOfon FS50 Pre-formed polyethylene foam flanking angle: 6 mm x 50mm x 0mm x m installed around the perimeter of the flooring board to isolate floor from walls and skirting. Ceiling board fixings must not penetrate or touch the floor joists 0mm Cellecta HP0 esilient Bars mounted at right angles to the joist at 600mm (max) centres. CT1-Two layers of gypsum-based board, composed of 19mm (nominal 1.5kg/m ) fixed with mm screws and 1.5mm (nominal 10kg/m ) fixed with 4mm screws, with all joists staggered. CT-Two layers of gypsum-based board, composed of 15mm (nominal 1.5kg/m ) fixed with 5mm screws and a second layer of 15mm (nominal 1.5kg/m ) fixed with 4mm screws, with all joists staggered. Product information Board dimensions: 8mm x 600mm x 100mm Edge profile: Interlocking tongue & groove Weight: 6.00kg/m / 18.7kg per board Cellecta SB joint adhesive: 1L to every m of boards 0mm (min) Typical PCT () performance D nt,w + C tr = 50dB L nt,w = 57dB Pol 1 1 Mat 1 Hea 0mm Construction notes Materials must be installed in accordance with manufacturers instructions to achieve stated acoustic values. Wall treatments MUST be isolated from the floating floor with YELOfon FS50 flanking strip. Ensure services do not bridge the resilient layer. Services must not puncture primary ceiling lining (except cables, which should be sealed with flexible sealant). * Code for Sustainable Homes (CSH) credits quoted are typical. Mat 1 value taken from the BE Green Guide. Pol 1 credit is only awarded if all the other insulation products used have a GWP of <5. Hea credits are based on the floor being pre-completetion tested and the separating wall performing to at least the same acoustic standard. Credits subject to relevant category weighted value. See page 5 for further information. Acoustic values () Values quoted are typical, based on the treatment being installed correctly and pre-completion tested. Airborne performance tested in accordance with BS EN ISO 140-4:1998 Impact performance tested in accordance with BS EN ISO 140-7: 1998 1

Structural separating floor - Timber (existing) PCT solution Existing timber joists Acoustic treatment laid on sub-floor Ceiling on resilient boards Floating floor treatment options Cellecta ScreedBoard 8 (See Table TF15 for full details) Floor decking Joists Absorbing material Ceiling 15mm thick (min) OSB or existing floor boards (with all gaps sealed with suitable flexible mastic) Solid timber joists 50mm Cellecta FIBEfon Micro 50 100mm (min) mineral wool insulation (45kg/m ) between joists See Table TF15 for ceiling treatment Fig. TF15 FASTACKCAD ACHITECTUAL CAD DATABASES Table TF15 PCT floating floor treatment options Perimeter resilient flanking strip required Ceiling treatment ScreedBoard 8 High density composite resilient overlay treatment No need for screws Interlocking edges glued together with Cellecta SB joint adhesive Typical PCT () performance w + C tr = 5dB L n,w = 54dB YELOfon FS50 Pre-formed polyethylene foam flanking angle: 6mm x 50mm x 0mm x m installed around the perimeter of the flooring board to isolate floor from walls and skirting. Ceiling boards must not penetrate or touch the floor joists 16mm (min) metal resilient bars mounted at right angles to the joist at 400mm centres. Ceiling treatment Two layers of gypsum-based board, composed of 15mm (nominal 1.5kg/m ) fixed with 5mm screws and a second layer of 15mm (nominal 1.5kg/m ) fixed with 4mm screws, with all joists staggered. Product information Board dimensions: 8mm x 600mm x 100mm Edge profile: Interlocking tongue & groove Weight: 6.00kg/m / 18.7kg per board Cellecta SB joint adhesive: 1L (to suit m board coverage) Underfloor heating below floating floor treatment (option 1) oute XFLOO 50 High performance extruded polystyrene boards (option ) outed or moulded expanded polystyrene (EPS) panel Typical Typical PCT PCT performance () () performance w + C tr = 5dB L n,w = 54dB () YELOfon ES5/100 Polyethylene foam flanking strip: 5mm x 100mm x 50m installed around the perimeter of the flooring board to isolate floor from walls and skirting. Construction note Services must not puncture ceiling linings (except cables, which should be sealed with flexible sealant). Construction notes Materials must be installed in accordance with manufacturers instructions to achieve stated acoustic values. Wall treatments MUST be isolated from the floor treatment with YELOfon FS50 or ES5/100 flanking strip. Ensure services do not come into contact with the floor treatment. Acoustic values () Test data quoted was conducted in a UKAS accredited laboratory in accordance with Approved Document E: Annex B: Procedures for sound insulation testing. Airborne results tested in accordance with BS EN ISO 140-:1995 Impact results tested in accordance with BS EN ISO 140-6: 1998 1

Masonry separating wall with timber separating floor Patent Pending Cellecta composite acoustic wall lining system Suitable for aircrete and aggregate block cavity walls Cellecta ScreedBoard 8 laid on timber sub-floor Masonry wall (Inside skin) Wall Floating treatment finish floor Treatment Absorbing material Floor decking Floor treatment Masonry wall Joists Floor decking Joists Absorbing material PCT solution 100mm (min) aircrete block 600-800kg/m 100mm (min) aggregate block 150-00kg/m Cellecta FIBEfon FFT1 - DECKfon Hi FIBEfon GYP Batten fixed Baffle 70to 16mm strips stuck resilient (See Table horizontally bars 11 set for at full at 600mm details) the head (max) and centres base of (See the Table wall, MW1 and vertically for treatment 600mm options) (max) centres 15mm FIBEfon MICO SLAB 15 Cellecta fitted in resilient FIBEfon bar void HiGYP 0TM fixed through the Baffle strips, to the wall with Cellecta AF10 fixings 11mm thick (min) OSB or Walker Cellecta perforated deck ScreedBoard system 8 (See Table TM1 for full details) 15mm thick (min) OSB 40mm (min) timber I-joists 5mm (min) metal web joists 100mm (min) quilt insulation (10-6kg/m ) in ceiling cavity Ceiling See Table TM1 for ceiling treatment Fig. TM1 FASTACKCAD ACHITECTUAL CAD DATABASES Proposed obust detail o Application N 181 & 18 Table TM1 PCT flanking wall, floating floor and ceiling treatment ScreedBoard 8 YELOfon FS50 High density composite resilient overlay treatment Preformed flanking angle FIBEfon HiGYP 0TM High performance composite acoustic wall lining FIBEfon Baffle Strips High performance sound absorption strips Additional layers required to complete treatment Mineral wool quilt placed in ceiling cavity - 100mm (min) 10-kg/m Typical PCT (4) performance D nt,w + C tr = 5dB L nt,w = 5dB No need for screws Interlocking edges glued together with Cellecta SB joint adhesive Code credits Pol 1 Hea 1 Construction notes Materials must be installed in accordance with manufacturers instructions to achieve stated acoustic values. Wall treatments MUST be isolated from the floating floor with YELOfon FS strip. Ensure services do not come into direct contact with the floor treatment. Acoustic values () Values quoted are typical, based on the treatments being installed correctly and pre-completion tested. Airborne performance tested in accordance with BS EN ISO 140-4:1998 Impact performance tested in accordance with BS EN ISO 140-7: 1998 Ceiling board fixings must not penetrate or touch the floor joists 0mm Cellecta HP esilient bars resilient bars mounted at right angles to the joist at 600mm (max) centres. Primary ceiling: CT1-Two layers of gypsum-based board, composed of 19mm (nominal 1.5kg/m ) fixed with mm screws and 1.5mm (nominal 10kg/m ) fixed with 4mm screws, with all joists staggered. CT-Two layers of gypsum-based board, composed of 15mm (nominal 1.5kg/m ) fixed with 5mm screws and a second layer of 15mm (nominal 1.5kg/m ) fixed with 4mm screws, with all joists staggered. Optional sacrificial ceiling: Metal ceiling system with a 100mm (min) void can be fixed to the underside of primary ceiling. One layer of nominal 8kg/m gypsumbased board. 14

Masonry flanking wall with timber separating floor Patent Pending Absorbing material PCT solution Cellecta composite acoustic wall lining system Suitable for aircrete and aggregate block cavity walls Cellecta ScreedBoard 8 laid on timber sub-floor Masonry wall (Inside skin) Floating Wall finish treatment floor Treatment Absorbing material Floor decking Floor treatment Masonry wall Joists Floor decking Joists 100mm (min) aircrete block 600-800kg/m 100mm (min) aggregate block 150-00kg/m Cellecta FIBEfon FFT1 - DECKfon Hi FIBEfon GYP Batten fixed Baffle 70to 16mm strips stuck resilient (See Table horizontally bars 11 set for at full at 600mm details) the head (max) and centres base of (See the Table wall, MW1 and vertically for treatment 600mm options) (max) centres 15mm FIBEfon MICO SLAB 15 Cellecta fitted in resilient FIBEfon bar void HiGYP 0TM fixed through the Baffle strips, to the wall with Cellecta AF10 fixings 11mm thick (min) OSB or Walker Cellecta perforated deck ScreedBoard system 8 (See Table TM1 for full details) 15mm thick (min) OSB 40mm (min) timber I-joists 5mm (min) metal web joists 100mm (min) quilt insulation (10-6g/m ) in ceiling cavity Fig. TM Ceiling Cavity insulation See Table TM for ceiling treatment 75mm (min) full fill mineral wool to address thermal bypass effect (10-6kg/m ) FASTACKCAD ACHITECTUAL CAD DATABASES Table TM Proposed obust detail o Application N 181 & 18 PCT separating wall, floating floor and ceiling treatment ScreedBoard 8 YELOfon FS50 High density composite resilient overlay treatment Preformed flanking angle FIBEfon HiGYP 0TM High performance composite acoustic wall lining FIBEfon Baffle Strips High performance sound absorption strips Additional layers required to complete treatment Mineral wool quilt placed in ceiling cavity - 100mm (min) 10-kg/m Product information ScreedBoard 8: 8mm x 600mm x 100mm YELOfon FS50: 50mm x 0mm x 000m HiGYP 0TM: 0mm x 100mm x 400mm Thermal resistance: 0.51m K/W Baffle Strips: 15mm x 75mm x 100mm AF10 fixings: 10mm x 8mm Typical PCT (4) performance D nt,w + C tr = 5dB L nt,w = 5dB Code credits Pol 1 Hea 1 Construction notes Materials must be installed in accordance with manufacturers instructions to achieve stated acoustic values. Wall treatments MUST be isolated from the floating floor with YELOfon FS strip. Ensure services do not come into direct contact with the floor treatment. Acoustic values () Values quoted are typical, based on the treatments being installed correctly and pre-completion tested. Airborne performance tested in accordance with BS EN ISO 140-4:1998 Impact performance tested in accordance with BS EN ISO 140-7: 1998 Ceiling board fixings must not penetrate or touch the floor joists 0mm Cellecta HP esilient bars resilient bars mounted at right angles to the joist at 600mm (max) centres. Primary ceiling: CT1-Two layers of gypsum-based board, composed of 19mm (nominal 1.5kg/m ) fixed with mm screws and 1.5mm (nominal 10kg/m ) fixed with 4mm screws, with all joists staggered. CT-Two layers of gypsum-based board, composed of 15mm (nominal 1.5kg/m ) fixed with 5mm screws and a second layer of 15mm (nominal 1.5kg/m ) fixed with 4mm screws, with all joists staggered. Optional sacrificial ceiling: Metal ceiling system with a 100mm (min) void can be fixed to the underside of primary ceiling. One layer of nominal 8kg/m gypsumbased board. 15

Cellecta I N N O V A T I O N I N I N S U L A T I O N ScreedBoard The ultimate floor board... Videos News New Build efurb More Cellecta Concrete and Steel Separating Floors Introduction In most cases, the mass of a concrete based floor accounts for the airborne sound that needs to be eliminated to conform with the required acoustic values, which leaves impact sound to be resolved. This can be addressed with ScreedBoard or one of Cellecta s extensive range of acoustic treatments, which have been specifically designed to suit each application. Each treatment combines a high performance resilient layer and perimeter flanking strip that, when installed correctly, will exceed the acoustic standards of Approved Document E of the 00 edition of the Building egulations, with the majority also being obust detail compliant. Key Benefits of Cellecta Acoustic Floor Insulation Excellent acoustic performance Cost effective, proven constructions Wide range of obust details and Pre-completion solutions BBA verified data Code for Sustainable Homes Pol.1 compliant Environmentally friendly Cellecta App E V D I F I BBA D A T E D A obust detail Acoustic Treatment FEATUED POJECT POJECT NAME Shenley Wood Care Village Milton Keynes PODUCT INSTALLED ScreedBoard 8 POJECT SIZE 17,000m² TYPE OF CONSTUCTION LGS Steel Frame POJECT COMPLETION June 01 For other projects please visit 16

Separating floor - Steel-concrete composite obust detail E-FS-1 In-situ concrete slab supported by profiled metal deck Floor Treatment Cellecta ScreedBoard 8 Cellecta ScreedBoard 0 + routed or mouled UFH insulation panel and Cellecta FIBEfon8 resilient layer Fig. SF shows ScreedBoard 8 and FS50 pre-formed flanking strip Structural floor Ceiling In-situ concrete slab supported by profiled metal decking: Shallow or deep profiled metal decking Overall distance from top surface of concrete to underside of ceiling treatment 00mm (min) Concrete thickness 80mm (min) at shallowest point and 10mm at deepest point Concrete density 00kg/m (min) See Table SF1a for ceiling treatment options Table SF1a FASTACKCAD ACHITECTUAL CAD DATABASES Ceiling treatment options for E-FS-1 (can be used with any FFT detailed in Table FS1b) Any ceiling system One layer of nominal 8kg/m gypsum-based board 00mm (min) Construction notes Materials must be installed in accordance with manufacturers and obust detail instructions to achieve required acoustic performance values. Wall treatments MUST be isolated from the floating floor with YELOfon ES or FS flanking strip. 17

Separating floor - Concrete obust detail E-FC-1 Pre-cast concrete plank with fully bonded screed Floating Floor Treatment floor Cellecta ScreedBoard 8 treatment options Cellecta ScreedBoard 0 + routed or mouled UFH insulation panel and Cellecta FIBEfon8 resilient layer Screed Structural floor Ceiling 40mm (min) screed directly applied to plank Sand: cement or proprietary screed 80kg/m (min) mass per unit area 150mm (min) precast concrete floor plank slab 00kg/m (min) mass per unit area See Table CF1a for ceiling treatment options Fig. CF1 shows FIBEfon 8C and FS0 pre-formed flanking strip FASTACKCAD ACHITECTUAL CAD DATABASES Table CF1a Ceiling treatment options for E-FC-1 (can be used with any FFT detailed in Table CF1b) CT1- Metal ceiling - 100mm void 100mm (min) One layer of nominal 8kg/m gypsum-based board CT-Timber batten & counter battens One layer of nominal 8kg/m gypsum-based board 100mm (min) CT- Metal ceiling - 75mm void 75mm (min) One layer of nominal 10kg/m gypsum-based board CT4-Timber batten & metal resilient bars 65mm (min) One layer of nominal 10kg/m gypsum-based board Construction notes Materials must be installed in accordance with manufacturers and obust detail instructions to achieve required acoustic performance values. Wall treatments MUST be isolated from the floating floor with YELOfon ES or FS flanking strip. 18

Separating floor - Concrete obust detail E-FC- In-situ concrete slab Only use with reinforced concrete frame construction Floating Floor Treatment floor Cellecta ScreedBoard 8 treatment options Cellecta ScreedBoard 0 + routed or mouled UFH insulation panel and Cellecta FIBEfon8 resilient layer Structural floor Ceiling 50mm (min) in-situ concrete slab, 400kg/m density without screed 00mm (min) in-situ concrete slab 400kg/m density with screed: 40mm sand & cement screed or 80kg/m (min) proprietary screed directly applied to slab See Table CFa for ceiling treatment options FASTACKCAD ACHITECTUAL CAD DATABASES Table CFa Ceiling treatment options for E-FC- (can be used with any FFT detailed in Table CFb) Any ceiling system - 75mm void 75mm (min) One layer of nominal 10kg/m gypsum-based board Any ceiling system - 100mm void 100mm (min) One layer of nominal 8kg/m gypsum-based board Construction notes Materials must be installed in accordance with manufacturers and obust detail instructions to achieve required acoustic performance values. Wall treatments MUST be isolated from the floating floor with YELOfon ES or FS flanking strip. 19

Separating floor - Metal Joists PCT solution Cellecta ScreedBoard 8 laid on sub-floor Metal joists C-section joists Use with lightweight metal frame walls only Floating floor treatment Floor decking Joists Absorbing material Ceiling Cellecta ScreedBoard8 (See Table SF for full details) 0mm thick (min) wood based board, density 600kg/m (mm) 54mm (min) deep metal C-section joists 100mm (min) mineral wool quilt insulation (10-6g/m ) between joists See Table SF for ceiling treatment options Fig. SF FASTACKCAD ACHITECTUAL CAD DATABASES Table SF PCT floating floor treatment Perimeter resilient flanking strip required Ceiling treatment options ScreedBoard 8 High density acoustic composite overlay board Ceiling board fixings must not penetrate or touch the floor joists Additional layers required to complete treatment Mineral wool quilt laid between joists - 100mm (min) 10-kg/m No need for screws, interlocking edges glued together with Cellecta SB joint adhesive YELOfon FS50 Pre-formed polyethylene foam flanking angle: 6 mm (t) x 50mm (w) x 0mm (h) x m(l) placed around the perimeter of the flooring board to isolate floor from walls and skirting. 5mm (min) 16mm (min) metal resilient bars mounted at right angles to the joist: Two layers of gypsum-based board, composed of 19mm (nominal 1.5kg/m ) fixed with mm screws and 1.5mm (nominal 10kg/m ) fixed with 4mm screws, with all joists staggered. Product information Board dimensions: 8mm (t) x 600mm x 100mm Edge profile: Interlocking tongue & groove Weight: 6.00kg/m / 18.7kg per board Cellecta SB joint adhesive: 1L to every m of boards Typical PCT () performance D nt,w + C tr = 51dB L nt,w = 56dB Pol 1 Hea 1 Two layers of gypsum-based board, composed of 15mm (nominal 1.5kg/m ) fixed with 5mm screws and a second layer of 15mm (nominal 1.5kg/m ) fixed with 4mm screws, with all joists staggered. 5mm (min) metal resilient bars mounted at right angles to the joist: Two layers of gypsum-based board, composed of 10mm (nominal 1kg/m ) fixed with 0mm screws and a second layer of 10mm (nominal 10kg/m ) fixed with 0mm screws, with all joists staggered. Construction notes Materials must be installed in accordance with manufacturers instructions to achieve required acoustic performance values. Wall treatments MUST be isolated from the floating floor with YELOfon ES50 perimeter flanking strip. * Code for Sustainable Homes (CSH) credits quoted are typical. Mat 1 value taken from the BE Green Guide. Pol 1 credit is only awarded if all the other insulation products used have a GWP of <5. Hea credits are based on the floor being pre-completetion tested and the separating wall performing to at least the same acoustic standard. Credits subject to relevant category weighted value. See page 5 for further information. Acoustic values () Values quoted are typical, based on the treatment being installed correctly and pre-completion tested. Airborne performance tested in accordance with BS EN ISO 140-4:1998 Impact performance tested in accordance with BS EN ISO 140-7: 1998 0

Ceiling Treatments Introduction The resistance to airborne sound depends mainly on the mass per unit area of the structural floor and partly on the ceiling s construction. It is therefore important to choose a ceiling treatment that complements the performance of the chosen structural floor, to produce an overall structure that exceeds the required db values. De-coupling the ceiling from the structural floor is an effective way of reducing the contact path that impact sound can follow. Adding mass in the way of plasterboard to the floor structure and filling the ceiling void with a mineral wool will also improve the acoustic performance of the structure. Listed below are three types of ceiling treatments available in order of performance. Ceiling Treatment A: Independent ceiling Ceiling Treatment B: Plasterboard on proprietary resilient bars with absorbing material 1. Proprietary resilient bars fixed to timber battens Cavity filled with 50mm Cellecta FIBEfon Micro 50 or 100mm mineral wool (10kg/m ). Up to 450mm centres Cellecta. Cellecta HP0 resilient bars fixed to timber Cavity filled with 50mm Cellecta FIBEfon Micro 50 or 100mm mineral wool (10kg/m ). 1) Independent joists Cavity filled with 50mm Cellecta FIBEfon Micro 50 or 100mm mineral wool (10kg/m ). Up to 600mm centres (A). Proprietary metal frame suspended ceiling system (A) ) Proprietary metal frame suspended ceiling system Cavity filled with 50mm Cellecta FIBEfon Micro 50 or 100mm mineral wool (10kg/m ). Ceiling Treatment C: Plasterboard on timber battens or proprietary resilient channels with absorbing material Cavity filled with 50mm Cellecta FIBEfon Micro 50 or 100mm mineral wool (10kg/m ). 1. Timber battens (A) ) Proprietary metal frame suspended ceiling system Cavity filled with 50mm Cellecta FIBEfon Micro 50 or 100mm mineral wool (10kg/m ).. Proprietary resilient channels Notes (A) The use of a better performing ceiling is permitted provided there is no significant flanking transmission. Professional advice should be sort to ensure the overall floor construction complies with current fire regulations. Further guidance is given in Approved Document E, Section 5 of the Scottish Building Standards and the obust details handbook. The manufacturer of the proposed ceiling system should also be consulted. 1

Cellecta I N N O V A T I O N I N I N S U L A T I O N ScreedBoard The ultimate floor board... Videos News New Build efurb More Cellecta Under Floor Heating Introduction In applications such as concrete ground floors where acoustic performance is not essential but an underfloor heating system is to be installed, ScreedBoard 0 is the ideal solution. ScreedBoard 0 features very low thermal resistance properties (0.05W/mk) which allows underfloor heating systems to work at their optimum efficiency. Typically this equates to a 0% increase in the efficiency of the heat pump over using timber based flooring products (i.e chipboard), giving the home owner greatly reduced running cost for the duration of the buildings life. Key Benefits ScreedBoard 0 Low thermal resistance (0.05m /kw) Doesn't contract or expand when exposed to water High impact resistance Interconnecting edge detail - no screws required Quick and easy to install Accepts ceramic tiles FASTACKCAD ACHITECTUAL CAD DATABASES Cellecta App Thermal esistance of Typical Overlay Floor Treatments Scree db oard 0 0.05 ScreedBoard 0 outperforms other overlay floor treatments traditionally used in underfloor heating applications

Under Floor Heating In-situ concrete slab Floating Floor Treatment floor Cellecta ScreedBoard 0 + routed treatment options or moulded UFH insulation panel Structural floor Concrete or timber base structural sub floor with a levelness in line with the S standard (+/- mm over m straight edge) Pol 1 Hea 1 FASTACKCAD ACHITECTUAL CAD DATABASES Floating Floor Treatment floor Cellecta ScreedBoard 0 + routed treatment options or moulded XFLOO 50 UFH insulation panel Structural floor Concrete or timber base structural sub floor with a levelness in line with the S standard (+/- mm over m straight edge) Pol 1 Hea 1 FASTACKCAD ACHITECTUAL CAD DATABASES THEMAL ESISTANCE ScreedBoard 0 has the lowest thermal resistance when compared to the most commonly used floor finishes, allowing ground water heat pumps and heat recovery systems to work at maximum efficiency. Intensity of heat flow obust detail FFT1 m /kw 0.7 ScreedBoard 0 m /kw 0.05 18mm Chipboard m /kw 0.18 ScreedBoard 0 m /kw 0.05 75mm Screed m /kw 0.065 Thermal and acoustic applcations Thermal applications

Cellecta Eliminating Acoustic Flanking The acoustic efficiency of the floor or wall will be adversely affected should acoustic bridging between the acoustictreatment and the surrounding structures occur (known as flanking transmission). All floor finishes must be isolated from the surrounding walls (including plaster finish and skirting boards), door linings, services and other structural elements. To address acoustic flanking, Cellecta manufactures an extensive range of flexible extruded polyethylene edge strips to suit each specific treatment. DO NOT secure the floating floor treatment to the sub-deck or floor joists. DO NOT sit the skirting board or allow the plaster or plasterboard to make direct contact with the floor treatment. Ensure the acoustic floor treatment is free floating and not fixed to the sub-structure. Use YELOfon flanking strip to isolate the floating floor treatment from the wall and its finishes. Acoustic treatment Flanking strip required Flanking strip dimensions ScreedB oard 0 ScreedB oard 8 YELOfon FS50 (Profiled flanking strip) 6mm (t) x 50mm (w) x 0m (h) x 000mm (L) Note. All Cellecta edge strips have a global warming potential (GWP) of <5 and are Green Guide Pol 1 compliant.! Caution Failure to install a perimeter flanking strip correctly will result in acoustic failure 4

Cellecta Tools & Accessories ScreedBoard Fixing Batten ScreedBoard Pull Bar SB Adhesive - 1 litre bottle Coverage: m/ltr of ScreedBoard ScreedBoard Primer - 5 litre bottle Use to seal the Screedboards prior to adhering ceramic tiles Cellecta HP0 Deep esilient Bar Size: 0mm deep x 000mm long Spacing: > 600mm centres Cellecta fon Adhesive - 1 litre bottle Coverage: m/ltr of acoustic boards Further Information 5

Videos News New Build efurb More Cellecta obust detail ScreedBoard Specification Clauses Architects, designers and specifiers can quickly and easily insert one of Cellecta s acoustic treatments into their specification document, either by copying one of the specifications listed below, download the NBS clause from Cellecta s websire or by contacting Cellecta s technical team who will email the specific product s specification clause in a Word file. esilient overlay platform floor system (obust detail FFT4, E-FT-5, E-FT-6) The acoustic treatment shall be ScreedBoard 8 (obust detail FFT4, E-FT-5, E-FT-6 ) Sheet thickness: 8 Sheet size: 600mm x 100mm Perimeter edge strip: YELOfon FS50 strip Manufactured by: Cellecta Limited, Unit D Norman Close, Medway Valley Park, ochester, Kent. ME JU Tel. 08456 71-71-74 Email: technical@cellecta.co.uk Fit in accordance with manufacturer s instructions. esilient overlay platform floor system (obust detail FFT4, E-FT-5, E-FT-6) The acoustic treatment shall be a combination of ScreedBoard 0, UFH thermal insulation board and FIBEfon 8 (obust detail FFT4, E-FT-5, E-FT-6) Sheet thickness: ScreedBoard 0-0mm. FIBEfon 8-8mm Sheet size: ScreedBoard 0 & FIBEfon 8-600mm x 100mm Perimeter edge strip: YELOfon FS50 strip Manufactured by: Cellecta Limited, Unit D Norman Close, Medway Valley Park, ochester, Kent. ME JU Tel. 08456 71-71-74 Email: technical@cellecta.co.uk Fit in accordance with manufacturer s instructions. FASTACKCAD ACHITECTUAL CAD DATABASES ScreedBoard Installation Videos Installing ScreedBoard has never been easier, thanks to Cellecta s new installation videos. Featuring in-depth information on laying the boards, interlocking, adhesives and acoustic flanking the videos provide the best way to learn more about the ScreedBoard systems. Videos for both ScreedBoard 8 and ScreedBoard 8 have been developed for acoustic and under floor heating applications and are available to view at, via the Cellecta app or request a DVD. Cellecta I N N O V A T I O N I N I N S U L A T I O N ScreedBoard The ultimate floor board... 6