FIBRE-FREE DUCT INSULATION WITH A DURABLE AND AESTHETIC SILVER FINISH

Similar documents
NEW! THE FLEXIBLE PROFESSIONAL INSULATION WITH REVOLUTIONARY CHARACTERISTICS. even easier to use

Economically Priced Insulation For Domestic Heating & Plumbing Economically priced insulation for domestic heating and plumbing

NEW THE FLEXIBLE INSULATION WITH ANTIMICROBIAL PROTECTION

Praval Adhaulia K-FLEX INDIA PVT LTD

Tube Insulation. Fiber Free

PRODUCT SELECTION GUIDE

armaflex cryogenic systems

Pipe Supports Comparison

REFERENCE ARMA-CHEK SILVER

GUIDE SPECIFICATION: DUCT LINER

Thermasheath-XP. Insulation for Exposed Use

Insulwhite. Insulation WHITE-FACED THERMO REFLECTIVE INSULATION

DSC BUILDING 1200 ALTERATIONS OCTOBER 2011 SECTION DUCT INSULATION

EKVÜ seminar 11 mar 2016 Armacell/ Armaflex. Tallinn/ Estonia Petri Ojanen

Product Data Sheet. Product: Benchmark Wall Liner System

A. Deliver material to job site in original, nonbroken, factory packaging, labeled with manufacturer's density and thickness.

Controlled Environments. Product Data Sheet. Controlled Environment Panel System KS1100 CS

THE FLEXIBLE INSULATION SYSTEM TO PREVENT CONDENSATION AND ENERGY LOSSES

Permifloor. Insulation WATER-PERMEABLE UNDERFLOOR INSULATION

Design & Construction Standards, Revised January

Distributor : DAI VIET TRADING & TECHNICAL SERVICES COMPANY.,Ltd

Armacell Product Selection Guide

Redi-Klad 1000 Pipe Insulation

EcoTouch Insulation with PureFiber Technology

Eclipse Air Duct Board

Permicav XV TM NEXT GENERATION OF VAPOUR-PERMEABLE INSULATION FOR WALLS WITH CAVITIES

DUCTWRAP AND DUCTSLAB For the thermal insulation of ductwork and water storage tanks.

Retroshield XL TM. Insulation THERMO REFLECTIVE INSULATION

HVAC INSULATION. A. General Requirements for Flexible Elastomeric Insulation: 3. Use pre-molded roll on pipe sizes 3.5" and below.

SECTION PIPING INSULATION

The thickness of ROCKWOOL insulation

K8 Cavity Board. Insulation CAVITY WALL INSULATION

Highlights of DANA Insulated Sandwich Panels

Environmental credentials. Energy efficiency and environmental protection with KIMMCO glass mineral wool

SECTION HVAC INSULATION

K-FLEX K-FLEX ST 74 A NEW GENERATION OF INSULATION MATERIALS

University of Delaware

KoolthermTM FM. Project Specification. HVAC & Building Services Pipe Insulation

Controlled Environments. KS1100 CS Data Sheet. Controlled Environment Panels. Insulated Panels

Technical Guide. Adhesive Tapes

K-FLEX. K-FLEX Tapes. for HVAC and industrial application

SECTION HVAC PIPING INSULATION

Insulation Board. Knauf Data Sheet PE-DS

Originally Issued: 05/03/2013 Revised: 06/06/2016 Valid Through: 05/31/2017

Standard and Mini Split Line Sets

K-FLEX K-FLEX ST 84 A N E W G E N E R A T I O N O F I N S U L A T I O N M A T E R I A L S

ACOUSTIC INSULATION UNDER SCREED made from recycled rubber granules

HVAC-R & PROCESS SPECIFICATION GUIDE MAKING A DIFFERENCE AROUND THE WORLD. HVAC-R & Process Specification Guide

Technical Information Phonotherm 200

HVAC SPECIFICATION DETAIL GUIDE. A guide to specifying ROCKWOOL insulations for HVAC applications

Double Brick Cavity Walls

Thermablok Aerogel Isolation Strips Thermablok Aerogel Isolation Strips

K12 Framing Board. Insulation INSULATION FOR USE BEHIND WALL LINING AND FRAMED WALLS

Knauf Data Sheet PE-DS-2e Insulation Board. with ECOSE Technology

K12 Framing Board. Insulation

ARMACELL UK PRODUCT CATALOGUE HVAC-R & INDUSTRIAL

Brick Veneer Walls. Insulation

SEALING & BONDING SIKA FIRE PROTECTION SOLUTIONS

DRAFT - MOCA STANDARD for Fiber-Reinforced Magnesium Cement Board

ROOFS ROOFS WALLS FLOORS. Energy efficiency for constructions... Always environment-friendly...

KIMMCO CLEAN LINER (KCL)

DUKE UNIVERSITY CONSTRUCTION STANDARDS

Insulated Roof & Wall Panels. Foilback KS1000 FB Insulated Roof Panels. Product Data Sheet

TECHNICAL BULLETIN 0214 (update of 0111) PERFORMANCE/COST COMPARISON OF POLYISO vs. XPS PIPE INSULATION SYSTEMS

Insuliner. Insulation REFLECTIVE INSULATION FOR USE WHERE

K5 External Wall Board

SEALING & BONDING SIKA FIRE PROTECTION SOLUTIONS FOR JOINTS AND PENETRATIONS

Ammonia. Product performance for insulation of ammonia piping

MITIGATING CORROSION UNDER INSULATION (CUI) SPREAD OF CORROSION ASSESSMENT ON ARMAFLEX INSULATION SYSTEMS IN A CONTINUOUS SALT-WATER SPRAY ENVIRONMENT

Earthwool Redi-Klad 1000 Pipe Insulation

EDITION: EXPORT - PUBLISHED: 11/2013 NEW PRODUCT NAMES. ProRox. Product catalogue. Industrial insulation

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: REFLECTIX INCORPORATED

ROCKWOOL Board Insulation Section Master Guide Specification (ROCKBOARD 80) Page 1 January 2017

Dynamic Bonding Systems B.V. A division of Dutch Bonding Group B.V.

Thermal Laminate Board.

FIBER GLASS INSULATION. Thermal. Acoustical. Fire Resistant. Moisture Control. Recycled Content. Formaldehyde-free. Air Control FIBER GLASS INSULATION

AESTUVER fire-protection mastic For the AESTUVER expansion joint M

Insulation TECHNICAL DATA SHEET. Low Energy Low Carbon Buildings. CI/SfB (57.9) In7 (M2) First Issue April 2016

Construction. S-Vap 5000E SA Self-adhesive Vapour Barrier. Product Description

Regupol CONSTRUCTION. Regupol BA. Heavy duty screed isolation. Regupol BA. Excellent impact performance.

K5 External Wall Board

Insulbreak. Insulation. thermal break solution

ACOUSTICAL DUCT & PIPE LAGGING INDUSTRIAL NOISE CONTROL PRODUCTS

Ductslab and Ductwrap

Roofing. Carrier Membrane SA. Self-adhesive Carrier Membrane. Product Description. Tests. Product Data. Form. Storage

Residential Product Selector Guide

energy Solar reflective surfaces

EFRIGERATION INSTALLATION GUIDE

Type II Environmental Declaration according ISO 14021:2001/A1:2011

Eclipse Energy Guard. Product Information & Installation Manual General Installation Requirements

Polystyrene underlays (XPS)

Thermasheath -3. Insulation for the Building Envelope ROOF WALL SPECIALTY

Phenolic foam thermal insulation products for buildings and building services end use applications

Xtratherm Thin-R Partial Fill Cavity Wall Board (XT/CW Grade)

Earthwool Insulation Board with ECOSE Technology

Knauf Data Sheet PE-DS-1e Earthwool TM 1000 Pipe Insulation

Vinaflex Noise Barrier (VN)

Transcription:

FIBRE-FREE DUCT INSULATION WITH A DURABLE AND AESTHETIC SILVER FINISH Fibre-free to prevent potential air-quality problems Low thermal conductivity f ective energy saving Closed-cell insulation to provide a continuous barrier to water vapor Optimal surface design for lasting aesthetic impression Easy to apply exibility f Washable surface to support hygiene maintenance

Armaflex Duct Class 0 self-adhesive sheets, pre-covered Width 1.22 m and Length 1.0 m, foil faced Code Insulation thickness [mm] Width [m] Pieces/carton m²/carton ICO13122SZA 13.0. 1.22. 15. 18.3. ICO19122SZA 19.0. 1.22. 10. 12.2. ICO25122SZA 25.0. 1.22. 8. 9.76. Armaflex Duct Class 0 continuous sheets, pre-covered Width 1.22 m, foil faced Code Insulation thickness [mm] Width [m] Roll length [m] Pieces/carton m²/carton ICO13122SA0 13.0. 1.22. 8. 1. 9.76. ICO19122SA0 19.0. 1.22. 6. 1. 7.32. ICO25122SA0 25.0. 1.22. 4. 1. 4.88. Remarks For trimmed foiled-faced Armaflex Duct Class 0, the width tolerance is 1.18m - 0mm/ + 30mm. For untrimmed foiled-faced Armaflex Duct Class 0, the width tolerance is 1.2m - 0mm/ + 30mm. 2013 Armacell Enterprise GmbH Subject to alterations without prior notice. Our general conditions of sales & delivery shall apply. 3

Technical data - Armaflex Duct Class 1 Description Material Type Colour Applications Armaflex Duct Class 1 is a black, closed-cell insulation material available with a bright silver finish. It is especially designed and produced for the thermal and acoustic insulation of air-conditioning ducts. Armaflex Duct Class 1 insulation reduces heat losses and the closed-cell structure prevents water vapor transmission, thus avoiding the risk of corrosion. Aluminum foil covered sheets made of foamed synthetic rubber. Black/ Silver Insulation / protection for air ducts to prevent condensation and save energy. Property Value/ Assessment Special remarks Temperature Range Temperature Range max. service temperature min. service temperature + 85 C - 50 C For temperature above +85 C, please consult our Technical Department. Thermal Conductivity Thermal Conductivity Water Vapour Diffusion Resistance Water Vapour Diffusion Resistance m +/-0 + 20 + 40 [ C] Tested acc. to 0.034. 0.036. 0.038. W/(m K) ASTM C518 < 0.08 perm-inch Tested acc. to ASTM E96 Method A Fire Performance Reaction to fire Surface Spread of Flames Class 1 Tested acc. to BS 476 Part 7: 1997 Practical Fire Behaviour Self-extinguishing, no fire dripping Health Aspects Dust free & fibre free Water Absorption 0.2% by volume Tested acc. to ASTM C209 Environmental Aspects ODP zero, GWP zero All statements and technical information are based on results obtained under typical conditions. It is the responsibility of the recipient to verify with us that the information is appropriate for the specific use intended by the recipient. For outside use, Armaflex should be protected within 3 days, eg. with Armafinish Paint 99 or Arma-Chek covering. 4 2013 Armacell Enterprise GmbH & Co. KG Subject to alterations without prior notice. Our general conditions of sales & delivery shall apply.

Armaflex Duct Class 1 self-adhesive sheets, pre-covered Width 1.5 m and Length 1.0 m, Foil faced Code Insulation thickness [mm] Width [m] Pieces/carton m²/carton IC113150SZA 13.0. 1.5. 15. 22.5. IC119150SZA 19.0. 1.5. 10. 15. IC125150SZA 25.0. 1.5. 8. 12. Armaflex Duct Class 1 continuous sheets, pre-covered Width 1.5 m, Foil faced Code Insulation thickness [mm] Width [m] Roll length [m] Pieces/carton m²/carton IC113150SA0 13.0. 1.5. 8. 1. 12. IC119150SA0 19.0. 1.5. 6. 1. 9. IC125150SA0 25.0. 1.5. 4. 1. 6. Remarks For trimmed foiled-faced Armaflex Duct Class 1, the width tolerance is 1.18m - 0mm/ + 30mm. For untrimmed foiled-faced Armaflex Duct Class 1, the width tolerance is 1.2m - 0mm/ + 30mm. 2013 Armacell Enterprise GmbH & Co. KG Subject to alterations without prior notice. Our general conditions of sales & delivery shall apply. 5

Technical data - Armaflex Duct MC Description Material Type Colour Applications Armaflex Duct MC is a black, closed-cell insulation material also available with a bright silver finish. It is especially designed and produced for the thermal and acoustic insulation of air-conditioning ducts. Armaflex Duct MC insulation reduces heat losses and the closed-cell structure prevents water vapor transmission, thus avoiding the risk of corrosion. Aluminum foil covered sheets made of foamed synthetic rubber. Black/ Silver Insulation / protection for pipes, air ducts of air-conditioning / refrigeration and chilled water to prevent condensation and save energy. Property Value/ Assessment Special remarks Temperature Range Temperature Range max. service temperature min. service temperature + 85 C - 50 C For temperature above +85 C, please contact our Technical Department. Thermal Conductivity Thermal Conductivity Water Vapour Diffusion Resistance Water Vapour Diffusion Resistance m -20 +/- 0 24. 32. 40. [ C] Tested acc. to 0.032. 0.034. 0.036. 0.037. 0.039. W /(m K) ASTM CS18 ASTM C177 0.230. 0.240. 0.250. 0.260. 0.270. > 0.02 perm-in. Tested acc. to ASTM E96 Method > 2.8 x 10-11 Moisture Resistance ctor 7,000 A EN 12086 DIN 52615 Reaction to fire V-0, HB (TBC after testing) Tested acc. to UL 94 ASTM D635 (TBC after testing) Self-extinguishing, no fire dripping Behaviour Health Aspects Dust free & fibre free Water Absorption Tested acc.to ASTM D1056 ASTM C209 Environmental Aspects OD zero, GW zero All statements and technical information are based on results obtained under typical conditions. It is the responsibility of the recipient to verify with us that the information is appropriate for the specific use intended by the recipient. 6 2013 Armacell Enterprise GmbH & Co. KG Subject to alterations without prior notice. Our general conditions of sales & delivery shall apply.

Armaflex Duct MC continuous sheets, pre-covered Width 1.0 m and 1.22 m, Foil faced Code Insulation thickness Width [m] Roll length [m] Pieces/carton m²/carton [mm] AD-06122CS-15 6.0. 1.22. 15. 1. 18.3. AD-09122CS-10 9.0. 1.22. 10. 1. 12.2. AD-09122CS-15 9.0. 1.22. 15. 1. 18.3. AD-13122CS-15 13.0. 1.22. 15. 1. 18.3. AD-13122CS-8 13.0. 1.22. 8. 1. 9.76. AD-19122CS-15 19.0. 1.22. 15. 1. 18.3. AD-19122CS-6 19.0. 1.22. 6. 1. 7.32. AD-25122CS-15 25.0. 1.22. 15. 1. 18.3. AD-25122CS-4 25.0. 1.22. 4. 1. 4.88. AD-32122CS-6 32.0. 1.22. 6. 1. 7.32. AD-38122CS-6 38.0. 1.22. 6. 1. 7.32. AD-50122CS-6 50.0. 1.22. 6. 1. 7.32. Remarks For trimmed foiled-faced Armaflex Duct MC, the width tolerance is 1.18m - 0mm/ + 30mm. For untrimmed foiled-faced Armaflex Duct MC, the width tolerance is 1.2m - 0mm/ + 30mm. Self Adhesive Armaflex Duct Mc available on request. 2013 Armacell Enterprise GmbH & Co. KG Subject to alterations without prior notice. Our general conditions of sales & delivery shall apply. 7

c to ro a continuous barrier to water v si h giene R c thickness for ce Easy to apply (*) Step 1: ean surfaces using eaner to remove grease, oi, rt, etc. Measure surface cut ex sheet to mm. so that mat c ression. bottom of the Step2: the cut sheets at either s e of the ct. Step 3: Fin insu te the to of the ct. Step 4: a wet sea ication with esive to the c resse butt joints. using ta eaong the e ges of the insu te ct. Armacell (Thailand) Limited 88 Mu 4, Donkr Rat www.armac c f c com Armacell Asia Limited (Singapore Branch) r r rchar R ow re www.armac c f r c com Armacell Asia Limit reet War s www.armac c f c com Armacell Asia Ltd. (Indonesia Representativ ce) Menara Kar R ock X v kart www.armac c f c com Armac IPRN-0131-130809-en(TH, ID, VN, PH) www.armac c f c com c t K