EVW 2 Hynds Commercial Wastewater Systems April 2013

Similar documents
Severn Trent Services Wastewater Solutions End-to-End Wastewater Treatment Solutions

Environmental Septic Tank systems

by M k h GROVER Degremont

Sanitary Sewer Systems. Sewage Collection System. Types of Sewage 10/12/2016. General Overview

DISCUSSION PAPER. 1 Objective. 2 Design Flows and Loads. Capital Regional District Core Area Wastewater Management Program

Evaluation of Conventional Activated Sludge Compared to Membrane Bioreactors

BEING GOOD STEWARDS: IMPROVING EFFLUENT QUALITY ON A BARRIER ISLAND. 1.0 Executive Summary

membrane bioreactor performance compared to conventional wastewater treatment

Reclaimed Waste Water for Power Plant Cooling Tower Water & Boiler Feed Make-up. Richard Coniglio, Business Product Manager

Activated Sludge Treatment Extended Aeration (EA) and Sequencing Batch Reactor (SBR) Systems

demand special treatment SAF range techflo TM SAF single stream techflo TM SAF multi stream

SAF SAF SUBMERGED AERATED FILTER THE PARTNER OF CHOICE

SAF SAF SUBMERGED AERATED FILTER THE PARTNER OF CHOICE

Reducing Inputs: Irrigating with Winery Wastewater Mai Ann Healy, Regional Manager - BioFiltro

Recycling of Food Processing Wastewater to Potable Water Standards

Best practice in monitoring process, operation and maintenance of wastewater treatment plants 12 September 2011, Bucharest

MEMBRANE BIOREACTORS (MBR)

Traditional Treatment

W O C H H O L Z R E G I O N A L W A T E R R E C L A M A T I O N F A C I L I T Y O V E R V I E W

Operation of a small scale MBR system for wastewater reuse

AQUAROBIC MINI-PLANT TM

OPERATION OF AN STP FOR RECYCLED WATER PRODUCTION PLANT. Iain Fairbairn. Iain Fairbairn, Plant Manager, Sydney Water

Sulaibiya world s largest membrane water reuse project

- 1 - Retrofitting IFAS Systems In Existing Activated Sludge Plants. by Glenn Thesing

Aerofloat specialises in the treatment of greywater and industrial wastewater from a range of industries.

Puraflo Peat Fiber Biofilter for Clean Water

ONSITE SEWAGE SYSTEMS*

WASTEWATER TREATMENT SYSTEM

DELPHIN container. Mobile wastewater treatment plants. DELPHIN Water Systems GmbH & Co. KG The experts for fi xed-bed technology

Sustainable, Reliable, Affordable

WPL Diamond. Environmental Wastewater Solutions. EN approval Compact design No odours. Low visual impact Easy to install

Lagoons Operation and Management in New Brunswick

City of Redlands Wastewater Treatment Plant. Redlands, CA LOCATION: Carollo Engineers; CH2M HILL MBR MANUFACTURER: COMMENTS:

Remote Waste. (AOWMA) is the provincial, not-for profit, organization established to educate, train and certify industry professionals.

BIO-CEL -Modules. The Solution for state-of-the-art MBR-Technology. Backwashable - Self-Healing - Mechanically Cleanable

Water Technologies. The AGAR Process: Make Your Plant Bigger Without Making it Bigger

MBR MRI BIO-CEL. Ultra-Effective, Ultra-Filtration. MRI Bio-Cel MBR. Meurer Research, Inc Joyce Drive (303) FAX (303)

AquaPASS. Aqua MixAir System. Phase Separator. System Features and Advantages. Anaerobic. Staged Aeration. Pre-Anoxic.

Alexandria Sewage Lagoon Treatment Facility Municipal Class C Environmental Assessment Public Information Centre #2 Welcome!

NITROGEN REMOVAL USING TERTIARY FILTRATION. Suzie Hatch & Colum Kearney. Sydney Water Corporation

Dr Martin Peter *, Joachim Scholz & Victor Ferre. Contents

AquaNereda Aerobic Granular Sludge Technology

Tour of Regional Water Reclamation Facility

Winery FAST & Floating FAST

BIOMAG/COMAG FREQUENTLY ASKED QUESTIONS

Let us help! Free professional site visit with friendly support and advice. to make the right decision or call

COMPARISON STUDY BETWEEN INTEGRATED FIXED FILM ACTIVATED SLUDGE (IFAS), MEMBRANE BIOREACTOR (MBR) AND CONVENTIONAL ACTIVATED SLUDGE (AS) PROCESSES

Sustainable, Reliable, Affordable

Air Connection on Rack. Filtrate Connection on Rack

DEVELOPMENT OF THE. Ken Mikkelson, Ph.D. Ed Lang Lloyd Johnson, P.E. Aqua Aerobic Systems, Inc.

Watertown Wastewater Facility Plan. August 11, 2015

DELTA ENVIRONMENTAL ECOPOD SERIES

Membrane Bioreactors

RECYCLE, REUSE AND RECOVERY TECHNOLOGY WASTEWATER, BIOSOLIDS & WASTE MANAGEMENT

WASTEWATER TREATMENT. Nelson Environmental Inc. Nelson Environmental Inc.

Modular Effluent Treatment Plants

Membrane Bio-Reactors (MBRs) The Future of Wastewater Technology, Science and Economy Aspects

ISAM INTEGRATED SURGE ANOXIC MIX

MBBR Pack. The modular plug & play wastewater treatment solution WATER TECHNOLOGIES

THE USE OF MEMBRANE BIOREACTOR FOR WASTEWATER TREATMENT

Aqua MSBR MODIFIED SEQUENCING BATCH REACTOR

Lowering The Total Cost Of Operation

CHAPTER 7 WASTEWATER MANAGEMENT SYSTEMS FIVE OPTIONS

CITY OF OXFORD WASTEWATER TREATMENT FACILITY ANNUAL PERFORMANCE REPORT FOR THE CALENDAR YEAR OF 2012

THE NEW DUBBO SEWAGE TREATMENT PLANT UPGRADE. Glenn Clifford. Dubbo City Council

WASTEWATER TREATMENT

Diamond. Sewage Treatment. Small package sewage treatment plants for domestic and commercial properties

Module 17: The Activated Sludge Process - Part III Answer Key

Wastewater Treatment Works... The Basics

Regional Municipality of Halton Skyway Wastewater Treatment Plant Expansion Municipal Class Environmental Assessment Study

NON-ELECTRIC SEPTIC SYSTEMS

Flocculation Flotation Pretreatment Improves Operation of MBR Installed to Treat Snack Food Manufacturing Wastewater

COMPARISON OF SBR AND CONTINUOUS FLOW ACTIVATED SLUDGE FOR NUTRIENT REMOVAL

Environmental BA-BD. Envirosafe. Advanced Sewage Treatment Systems. Sustainable, Reliable, Affordable

6 WASTEWATER. 6.1 Overview. 6.2 Darvill Wastewater Works

Water Specialists for the Food & Beverage Sector creating value in water through innovation, creativity and expertise. ovivowater.

/ /

Fixed-Film Processes

solutions technology available in HDPE with competitive pricing, to produce the cleanest, Featuring our innovative Bio-Film Reactor

OWNER S, OPERATIONAL, AND MAINTENANCE MANUAL

BioWin 3. New Developments in BioWin. Created by process engineers.. for process engineers

Biotec 1-4 Package Sewage Treatment Plants

Nutrient Removal Processes MARK GEHRING TECHNICAL SALES MGR., BIOLOGICAL TREATMENT

Wastewater Treatment Processes

Nutrient Removal Optimization at the Fairview WWTP

Outline Introduction Membrane Issues Other Issues

STRUCTURAL AND OPERATIONAL STUDY OF 339 MLD SEWAGE TREATMENT PLANT AT AMBERPET

Appendix D JWPCP Background and NDN

Innovating Water Treatment Technologies in Managing Water-Energy Demand

Unit Treatment Processes in Water and Wastewater Engineering

Dealing with Unexpected Wastewater Treatment Plant Disruptions. February 16, 2017

Membrane Filtration Technology: Meeting Today s Water Treatment Challenges

AMMONIA REMOVAL USING MLE PROCESS EXPERIENCES AT BALLARAT NORTH. David Reyne. Central Highlands Water Authority

Pilot Studies on Performance of Membrane Bio-Reactor in Treating Hong Kong Freshwater and Saline Sewage and Its Virus Rejection Ability and Mechanism

Kirill Ukhanov, GE Water & Process Technologies, Russia, describes how advanced membrane technology is helping a Russian refinery to meet stringent

NON-ELECTRIC SEPTIC SYSTEMS

SMALL SEWAGE TREATMENT PLANTS WITH LOW RUNNING COSTS. Michael Nakulski. Michael Nakulski, General Manager, Kelair Pumps Australia

Tour of Altamonte Springs Regional Water Reclamation Facility

Application of MBR for the treatment of textile wastewater

Advanced Wastewater Treatment Plant Plant Profile

Transcription:

Hynds Commercial Wastewater Systems High quality sewage treatment systems Fully designed by qualified engineers Small footprint EVW 2 Hynds Commercial Wastewater Systems April 2013 0800 425 433 www.hyndsenv.co.nz

EVW 2 Hynds Commercial Wastewater Systems April 2013 Hynds Aerated Wastewater Systems The Hynds Submerged Aerated Filtration (SAF) Wastewater System is an advanced, modular sewage treatment system ideal for large residential and commercial developments requiring on-site secondary wastewater treatment. Utilising proven submerged aerated filtration technology, Hynds engineers can custom design your Hynds SAF Wastewater System to meet wastewater treatment and land application requirements. SAF technology incorporates primary anaerobic treatment followed by secondary submerged aerated filtration to produce an effluent quality typically better than 20 mg/l BOD 5 and 20 mg/l Suspended Solids. Tertiary treatment can be added to this process if a higher level of effluent is required. SAF systems are modular and can be sized for any application. The system can also be expanded at a later date if required to suit an expanding location. Applications Hynds SAF Wastewater Systems are suitable for any commercial site requiring on-site secondary wastewater treatment. Typical applications include: Subdivisions Schools Community halls Marae Campgrounds Factories Wineries and restaurants Parks and resorts Typical flows for Hynds Commercial Wastewater Systems range from 3,000 to 500,000 litres per day. A clear, odourless effluent is produced suitable for discharge to the surrounding countryside. Features Utilises proven technology Fully designed by qualified engineers Small footprint Modular design to suit varying capacities Protection for the system against surge flows Effluent is easily disinfected Simple retrofit for the upgrading of an existing system Alarmed system with full 24-hour emergency storage capacity Installed and fully maintained by trained personnel Low operation and maintenance costs 2

Hynds Aerated Wastewater Systems How it Works The Hynds SAF Wastewater System is a multiple-stage treatment process incorporated into modular tanks. Incoming wastewater is initially treated in a primary anaerobic treatment tank before passing through a biological solids filter and into a balance tank. Here, an advanced electronic control system regulates the flow into the main treatment tanks, protecting the system from surge loading and scouring of the filter media. Effluent then enters the submerged aerated filtration stage of the treatment process. Here, oxygen is infused into the water though fine bubble diffusers to create an aerobic environment. This oxygen sustains the micro-organisms, contained in unique biomass media, which cleans and filters the effluent. Hynds SAF Wastewater Systems utilise a dual aeration/filtration process to maximise the treatment of the wastewater. The effluent is then polished using a clarifier system before being pumped out via a drip irrigation network that automatically dose loads a suitably designed area. Commonly used areas for disposal are shrub landscaping, native bush, or tree stands. Irrigated areas are barked and landscaped. EVW 2 Hynds Commercial Wastewater Systems April 2013 Sizing and Design Hynds Environmental offers an engineering service to design the optimal solution for your site. Sizing of commercial wastewater systems is based on the peak flows expected. Typical flows for a Hynds SAF Wastewater System range from 3,000 to 150,000 litres per day. The system can be delivered to site in modules for quick and simple installation. To provide an accurate quotation to design and install a Hynds SAF Wastewater System, a trained technician will assess the physical requirements of the landowner and develop an understanding of the site s location, landscaping, and drainage requirements. For Hynds Environmental to complete the final design of the wastewater system, the owner will need to supply site plans and a geotechnical report for the site. Hynds Aerated Wastewater Systems 3

EVW 2 Hynds Commercial Wastewater Systems April 2013 Primary settling plus anaerobic treatment and return of activated sludge to primary tank Submerged treatment of the Performance System Maintenance Hynds SAF Wastewater Systems produce an effluent quality typically better than 20 mg/l BOD 5 and 20 mg/l Suspended Solids and remove over 99% of Faecal Coliforms. Hynds Pipe Systems Ltd manufactures all of the concrete components in a Telarc registered ISO9001 factory. Operation of the Hynds SAF Wastewater System is continuous and an advanced electronic alarm system is installed on site to alert the owner to the service requirements of the system. Hynds Environmental offers an annual contract to service the system. This will be completed by a trained technician. 4

Hynds Mbr Wastewater Systems The Hynds Membrane Bioreactor (MBR) Wastewater System is a state of the art, modular sewage treatment system ideal for large residential and commercial developments requiring on-site tertiary wastewater treatment. Utilising membrane bioreactor technology, Hynds MBR Wastewater Systems combine suspended growth biological treatment with immersed membrane technology to produce a tertiary level effluent quality that exceeds traditional treatment methods. EVW 2 Hynds Commercial Wastewater Systems April 2013 The effluent quality is typically better than 5:5:5 mg/l BOD 5 : Suspended Solids : Ammonia and the effective pore size of 0.01 microns (ultra filtration) removes viruses and pathogenic micro-organisms so further disinfection is not required. Its automatic operation, easy cleaning process and integral sludge storage coupled with small size, low odour and low noise generation ensures minimal environmental impact. MBR technology was developed as a result of a Japanese government initiative to produce high quality effluent from treatment plants with small footprints. Initially designed for commercial, municipal and industrial wastewater treatment applications, MBR technology can also be successfully applied to subdivisions, schools, campgrounds, parks and resorts. Applications Hynds MBR Wastewater Systems are suitable for any commercial site requiring on-site tertiary wastewater treatment. Typical applications include: Sub-divisions Schools Community halls Marae Campgrounds Factories Wineries and restaurants Parks and resorts Typical flows for Hynds Commercial Wastewater Systems range from 3,000 to 500,000 litres per day. A clear, odourless effluent is produced suitable for discharge to the surrounding countryside or may be reused in certain applications. Features The advantages of choosing a Hynds MBR Wastewater System include: Most advanced wastewater technology available Fully designed by qualified engineers Viruses are removed through ultra filtration so no further disinfection required Treated permeate may be available for reuse Simple retrofit for the upgrading of an existing system Alarmed system with full 24-hour emergency storage capacity Small plant footprint Not restricted by conventional limits of mixed liquor suspended solids (MLSS) concentrations can operate in the range 12 000 mg/l 20 000 mg/l Modular design that is easily expandable Low operation and maintenance costs 5

EVW 2 Hynds Commercial Wastewater Systems April 2013 Hynds Aerated Wastewater Systems Sizing and Design Hynds Environmental offers an engineering service to design the optimal solution for your site. The sizing of a Hynds MBR Wastewater System is based on the peak flows expected. Typical flows range from 3,000 to 500,000 litres per day. To provide an accurate quotation to design and install a Hynds MBR Wastewater System, a trained technician will assess the physical requirements of the landowner and develop an understanding of the site s location, landscaping and drainage requirements. For Hynds Environmental to complete the final design of the wastewater system, the owner will need to supply site plans and a geotechnical report for the site. How it Works The Hynds MBR Wastewater System produces a high quality disinfected effluent. The incoming wastewater generally only requires screening and de-gritting prior to entering the membrane bioreactor tank. The process requires no primary or secondary settlement stages and no additional tertiary treatment or UV stages. A very high effluent quality is achieved, typically better than 5:5:5 mg/l BOD 5 : Suspended Solids : Ammonia. Hynds MBR wastewater technology employs simple flat sheet membrane panels housed in stainless steel units and aerated by a coarse bubble system below each unit. A series of these membranes are submerged within an activated sludge treatment tank. The aeration generates an upward cross-flow over the membranes, essential to keep fouling of the filtration surface to a minimum. The membrane panels are securely retained and do not touch or abrade each other. The units also act as a flume to ensure effective tank mixing and even distribution of the biomass. The membrane panels are manufactured with a pore size in the range of 0.1 to 0.4 microns. In operation these panels become covered by a dynamic layer of protein and cellular material, providing an effective pore size of less than 0.01 microns. This is within the ultra filtration range. The treated permeate is then stored in a pump chamber where it is discharged, either directly into a receiving waterway or through a drip irrigation network. 6

Performance System Maintenance Hynds MBR technology treats wastewater at an ultra filtration level, ensuring that the following standards are met: Very high effluent quality is achieved, typically better than 5:5:5 mg/l BOD 5 : Suspended Solids : Ammonia Faecal Coliforms typically less than 5/100ml Effluent is rendered free of pathogens, viruses and bacteria Total nitrogen and total phosphorus removal can also be incorporated if required Operation of the MBR system is continuous and an advanced PLC alarm system is installed on site to alert the owner to the service requirements of the system. Hynds Environmental offers an annual contract to service the system. This will be completed by a trained technician. EVW 2 Hynds Commercial Wastewater Systems April 2013 Membrane Panel from fouling while water permeates through the membrane. MicroStructure During operation, the membrane panels provide an effective pore size of 0.01 micron. This is 7

EVW 2 Hynds Commercial Wastewater Systems April 2013 Hynds Environmental Systems Limited North Island PO Box 58142, Botany 2163, Auckland, New Zealand T +64 9 271 9503 F +64 9 272 7485 ni.sales@hyndsenv.co.nz South Island PO Box 16552, Hornby 8441, Christchurch, New Zealand T +64 3 344 1370 F +64 3 344 1375 si.sales@hyndsenv.co.nz 0800 425 433 www.hyndsenv.co.nz Disclaimer Users of the Hynds products within this document must make their own assessment for suitability for their particular circumstances. Product dimensions and specifications may vary according to factory of manufacture or changes from product improvement. No warranty either expressed or implied or statutory is made by Hynds in this document unless expressly stated in any sale and purchase agreement entered into between Hynds and the user.