FRANK MILLS INFECTION RATES HVAC ISSUES HVAC IN HEALTHCARE. Developments in ASHRAE and CIBSE

Similar documents
Complying with the Minimum Energy Efficiency Standards (MEES)

Air Conditioning Inspections for Buildings Assessing Equipment Sizing

DISPLACEMENT VENTILATION

Attaining Thermal Comfort in. Buildings with Predominantly. Glazed Facades. presented to: ANSYS Boston Regional Conference

Demonstration of modeling of radiant cooling system in design builder. Prashant Bhanware & Bharath Reddy

The Art of Thermal Mass Modeling for Energy Conservation in Buildings, Part 2

CHAPTER 3. BUILDING THERMAL LOAD ESTIMATION

ASHRAE - COLD-CLIMATE BUILDINGS DESIGN GUIDE (CCBDG)

ASHRAE s Initiatives for Energy Conservation in Existing Buildings

Chilled Beams. The new system of choice?

Green Star Shopping Centre Design PILOT Energy Calculator Guide

Great Ocean Rd Ice Creamery

Principles of Ventilation and Air Conditioning Design & Installation

Deep energy retrofit An Analysis of Energy Efficient Retrofit Strategies for Office Buildings in China

The Creative and Performing Arts High School (CAPA) Pittsburgh, PA 9/30/2002 Andrew Tech Mechanical Option Prof. S. A. Mumma

Assessment of the energy demand in energy-saving office buildings from the viewpoint of variations of internal heat gains

CFD Simulation of a High Tech Operating Room (OR) with Star-CCM+ Star Global Conference 2014

CIBSE LOW CARBON CONSULTANTS REGISTER SESSION 10 ENERGY EFFICIENCY IN BUILDINGS. I Prophets energy services

Draft Indoor Air Quality Regulations

EnergyPro Building Energy Analysis. Single-story School Building

NEW FOUR STORY MEDICAL CENTER OWNER S PROJECT REQUIREMENTS

Thermal comfort in a 21st century climate

Walter Reed National Military Medical Center Bethesda, MD

ENERGY CALCULATOR & MODELLING PROTOCOL

2001 National Workshop on State Building Energy Codes July th, 2001 Burlington, Vermont

Sustainable Chilled Beam Design

WEST VIRGINIA UNIVERSITY ALUMNI CENTER Morgantown, West Virginia

EDEM detail description part 1: inputs and outputs

The pros and cons of chilled beams

VE-Toolkits User Guide <VE> 6.0

Energy-Efficient Passive House using thermal mass to achieve high thermal comfort

THE REVISION OF STANDARD 62: WHAT A DIFFERENCE A DECADE MAKES

ARCH-MEDES (I) CONSULTANTS PVT. LTD. Green Park Delhi

LEED v4 Building Design and Construction Quiz #8 EQ

Updates to ANSI/ASHRAE/ASHE Standard , Ventilation of Health Care Facilities

Planning for Biomed Facility Puts Energy Efficiency Under Microscope

PassiveDesign.org. Passive Construction. Name:...

ENGINEERING UPDATE WHITE PAPER: BUILDING PERFORMANCE METRICS. price-hvac.com. May 2013 Vol. 10

DTS & ENERGY MODELLING PROTOCOL GUIDE Version 1.0

Senior Design Project for UNO. Design of the International Studies Building: An Environmental Analysis

Optimisation of an HVAC system for energy saving and thermal comfort in a university classroom

Asset Energy Calculator Guidance

The Palestra Building London, England

FEDERATION TOWER MOSCOW DIFFERENT ROOM CLIMATES UNDER ONE ROOF

Energy modeling in IDA ICE according to ASHRAE , app. G

General Specifications for HVAC System Cleaning

Building regulations now in force

THERMAL MASS IMPACT ON ENERGY PERFORMANCE OF A LOW, MEDIUM, AND HEAVY MASS BUILDING IN BELGRADE

International Health Facility Guidelines

Bruck an der Mur. Project summary. Energy concept: Background for the renovation reasons

Energy Trigger (A Existing Building Upgrade Mechanism Model)

Varennes Net-Zero Library City of Varennes

ApacheView user guide

Mission Critical Commissioning for Healthcare Facilities

Modeling Energy Consumption Effects of Glazing

COMMERCIAL LOAD ESTIMATING. Load Estimating Level 3: Block and Zone Loads. Technical Development Program

Construction Indoor Air Quality (IAQ) Management Plan

COMFORT DRIVEN ADAPTIVE WINDOW OPENING BEHAVIOR AND THE INFLUENCE OF BUILDING DESIGN

A Solar Wall System Utilized in Rural Houses of Northeast China

Volume 13, Issue 5/ Medtech

Modelling Analysis of Thermal Performance of Internal Shading Devices for a Commercial Atrium Building in Tropical Climates

Fresh Air Ideas SUPPORTING GREEN INITIATIVES WITH INNOVATION

CIBSE Application Manual AM11 Building Performance Modelling Chapter 4: Energy Modelling. Dr David Williams WSP Parsons Brinckerhoff

Available online at ScienceDirect. Energy Procedia 91 (2016 )

Can we feel safe in this building?

High Technology Energy Savings Guide

RETScreen ICE AND CURLING RINKS Model

ARPAN JOHARI. Architect. 13/08/10 AW Design. Ahmedabad

Engineering Evaluation of Generic New Build Health Buildings

Ceiling Radiant Cooling Panels

Available online at ScienceDirect. Energy Procedia 91 (2016 ) Esam Elsarrag and Yousef Alhorr

Energy Efficiency. best in class

Trane IntelliPak 2. Rooftop Comfort System

Design Strategies and Guide lines for Tropical Coast of Pakistan, Using Climate Consultant

Chilled Beams Selection BY DAN INT-HOUT, FELLOW ASHRAE; AND LILLI WILBAR

Update to ASHRAE Ventilation Standards. William P. Bahnfleth, PhD, PE, FASHRAE, FASME The Pennsylvania State University University Park, PA, USA

An Evaluation of the Total Energy Consumption of Educational Buildings: Prototype Case Studies in Saudi Arabia

Using CFD to Wring Out Energy Efficiency in Laboratory Settings

Ventilation standards EN15251 and ANSI/ASHRAE 62.1 Professor Bjarne W. Olesen, Ph.D.

Building Energy Analysis for a Multi-Family Residential Building (Multi V III VRF Heat-Pump System)

5. AMCA 301 Method of Publishing Sound Ratings for Air Moving Devices. 6. AMCA 500 Test Methods for Louver, Dampers, and Shutters

AIRCOOL VENTILATORS FURTHER INFORMATION

Save with Business Programs and Services

Italcementi Center for Research and Innovation

Updates on ANSI/ASHRAE/ASHE Standard , Ventilation of Health Care Facilities

Green Building Guideline of Jordan

RENOVATIONS & REFURBISHMENTS

The optimization of the mechanical night cooling system in the office building

LEED. Leadership in Energy and Environmental Design

Optimizing Indoor Environments for Occupant Satisfaction. Presented by: Kelli Goldstone April 2016

Available online at ScienceDirect. Procedia Engineering 145 (2016 ) 18 25

Thermo Active Building Systems Using Building Mass To Heat and Cool

2013 Nonresidential Energy Standards Overview

Work Package 2: Performance of naturally ventilated buildings

Promoting Building Energy Efficiency through Performancebased Standards: Is it a Challenge? By Priyantha Bandara

Voyager kw rooftop units Plug and Play comfort in commercial applications

Tate Laboratory of Physics Building Analysis

Earth, Wind & Fire Natural Airconditioning [1] Research objectives and Methods

INTEGRAL BUILDING AND ENERGY DESIGN OF AN OFFICE BUILDING COMPARISON OF INITIAL DESIGN IDEAS WITH MONITORED RESULTS

Transcription:

HVAC IN HEALTHCARE Developments in ASHRAE and CIBSE FRANK MILLS ENVIRONMENTAL DESIGN CONSULTANTS, CHORLEY, LANCASHIRE FRANK MILLS VICE CHAIR, CIBSE HEALTHCARE GROUP MEMBER ASHRAE TC 9.6 HEALTHCARE TECH COMMITTEE MEMBER DRAFTING COMMITTEE ASHRAE DESIGN GUIDE HVAC IN HOSPITALS MEMBER OF NHS EKNG HVAC ISSUES IAQ INFECTION CONTROL ENERGY USE RESILIENCE CAPITAL COST RUNNING COSTS SUSTAINABILITY INFECTION RATES In December 2000, Robert Bezell of NBC News reported It s a danger of staggering proportions. Every year 1 in 20 Americans 8 million people develop an infection, with 88,000 of them dying. The biggest threat : supergerms resistant to bacteria. 1

ASHRAE /ASHE IAQ 2004 A JOINT CONFERENCE HELD IN TAMPA TO DISCUSS HOSPITAL AIR QUALITY NIH RESEARCH DR FARHAD MEMARZADEH CFD AND PRACTICAL STUDIES LOOKED AT DIFFERENT AIRFLOW STRATEGIES RESULTS USED IN GUIDE ASHRAE DESIGN GUIDE HVAC DESIGN MANUAL FOR HOSPITALS AND CLINICS PUBLISHED IN 2003 FOREWORD INFORMATIVE BACKGROUND CASE FOR CONTROLLED VENTIALTION 2

PURPOSE VENTILATION SYSTEM DESIGN COMFORT ASEPSIS ODOUR CONTROL SCOPE HOSPITALS, NURSING FACILITIES, OUTPATIENT NEW BUILDINGS, EXTENSIONS, CHEMICAL,PHYSICAL, BIOLOGICAL CONTAMINANTS, DEFINITIONS REFER TO LIST FOR SCOPE. NON-ASPIRATING DIFFUSER 3 CLASSES OF SURGERY CLASS A CLASS B CLASS C ADMINISTRATION COMPLIANCE REQS NEW BUILD EXTENSIONS PLANT REPLACEMENT/SYSTEM UPGRADES SPACE ALTERATIONS 3

SYSTEMS AND EQUIPMENT COMFORT REMOVAL OF CONTAMINANTS AIRBORNE INFECTION CONTROL NFPA 99 EMERGENCY POWER HEATING SOURCES N + 1? ONLY MENTIONS HEAT SOURCE WHAT ABOUT REST OF SYSTEM? COOLING SOURCES NOT MENTIONED NO MENTION OF ALTERNATE SOURCES NOT n+1 4

FILTRATION SPECIFIC SEE TABLE 5.1 COOLING SYSTEMS AND DRAIN PANS REFERS TO APPENDIX C WHICH IS PART OF STANDARD. QUITE SPECIFIC IN PLACES, eg drain levels, trap depths, water carry over. THIS SECTION USES METRIC RATHER THAN IMPERIAL UNITS. HUMIDIFIERS BANS RESERVOIR AND EVAPORATIVE TYPES AIR DISTRIBUTION TABLE 5.2 CONCERNS SUPPLY DIFFUSERS SPECIFIC TYPES NON ASPIRATING FOR OPERATING THEATRES AND PROTECTIVE ENVIRONMENTS (LAMINAR FLOW) 5

LAMINAR AIR FLOW STANDARD PROPOSES A STANDARD DESIGN SOLUTION PRESCRIPTIVE APPROACH LOCATION OF SUPPLIES AND EXTRACTS SPECIFIES DIFFUSER TYPES orf.od.nih.gov/docs/or_esarticle.pdf SPACE VENTILATION TABLE 6.1 TEMPS, HUMIDITY, AIR CHANGE RATES THIS IS THE HEART OF THE STANDARD IN TERMS OF VENTILATION UNITS ARE MAINLY IMPERIAL FAN COILS VIRTUALLY OUTLAWED REIRC PERMITTED IN MOST ROOMS eg ORs can have 4 fresh air and 16 recirc airchanges per hour NATVENT not permitted due to pressure requirements, temperature, humidity or airchange rate reqs AIR CLEANERS UV SYSTEMS NOT MENTIONED LOCAL RECIRC HEPAFILTERS NOT MENTIONED BUT RULED OUT BY BAN ON IN ROOM UNITS 6

Airborne infections Where are the infections coming from? What are they? How can we stop them? What is the role of ventilation? Are our designs right? Are our installations right? DESIGN OBJECTIVES What is the design trying to achieve? There is no Internationally agreed standard There are very big differences between so called advanced countries Why? What about developing countries? Ventilation engineers do not have a clear view on modern hospital ventilation requirements UK PRACTICE NHS GUIDANCE EFFECTIVELY A REQUIREMENT BEFORE PFI- BUT NOT SO NOW. HTM 2025 IN PROCESS OF REVISION FULL FRESH AIR NO RECIRCULATION NATVENT ENERGY RISING COSTS FUEL AVAILABILITY CARBON EMISSIONS KYOTO COMMITMENT SUSTAINABILITY HEALTH AND WELLBEING 7

LOW ENERGY HOSPITAL STUDY, 1990 Gain an understanding of the key functional and comfort related factors that influence energy use. Establish an energy datum against which energy saving meassures can be evaluated. Examine measures that reduce the energy demand of environmental and process systems at the point of use. Determine the grades of energy required to satisfy the reduced energy demand. Examine the possibilities for the recovery of heat as a means of offsetting energy demand. Consider energy supply options, taking into account fuel characteristics and availability, patterns and grades of residual energy demand and the overall integration of systems. HEAT RECOVERY Examination of patterns and grades of energy shows that a large proportion of a hospital demand is for low grade heat. Also heat from recovery sources such as exhaust air, refrigeration condensers and from solar energy can provide a substantial part of the low grade heat required. Some of the systems for example, run around coils, can be described as dedicated systems. That is, a direct transfer of heat occurs from the exhaust to the supply of a particular ventilation system. In dedicated systems of this type the recovered heat is only useful when there is a demand for that grade of heat within that same system. Heat recovery can redirect surplus heat to areas needing heat WHY HAVE BOILERS? PART L 2005 REDUCES CARBON EMISSIONS BY 28% BUILDING FABRIC KEEPS HEAT IN HEAT PRODUCED BY PROCESSES WITHIN LINACS,MRIs,MEDICAL EQUIPMENT OCCUPANCY IS 24 HRS/DAY/365 DAYS/YEAR HEAT SURPLUS DUE TO USE OF BUILDINGS UK HTM2025 REQUIRES FULL FRESH AIR THEREFORE BIG AIR HEATING LOAD USE HEAT RECOVERY TO GET HEAT BACK FROM EXHAUST AIR 8

ENERGY TARGET The Minister of State for Health in April 2001 stated target for new hospitals 35 to 55 GJ per 100m³. BENCHMARKING Current hospitals Large Hospitals (greater than 25,000m3) Low Consumption Less than 70 Medium Consumption 70 to 80 High Consumption Above 80 CALCULATING VOLUME UNCLEAR ERICs EnCode 2005 This EXCLUDES untreated space such as:- ceiling voids Risers Plant rooms Non-heated, non ventilated stores Volume EXCLUDES ceiling voids unless ceiling is not insulated (and therefore void is heated). REAL ENERGY CONSUMPTION MUST INCLUDE SYSTEM LOSSES Ductwork distribution and plant losses + 10%. Commissioning, Balancing + 10%. The plant duties are therefore +20% of the room calculated 9

THERMAL SIMULATION The computer model has information on the construction of the building the floor, walls, windows, roofs and internal partitions. Each element of the of the construction plaster, blockwork, concrete, glass etc has physical properties which enable the programme to calculate:- thermal insulation rates of heat flows thermal energy stored in the structural mass amount of solar radiation (solar gain) THERMAL SIMULATION The building services engineering systems are also described:- type of heating natural ventilation mechanical type of cooling lighting electrical power. HOURS OF USE Each department has occupancy profiles which establish the times at which engineering systems operate, when occupants use rooms, the set point, and permitted control band which systems follows. WEATHER DATA The simulation then uses actual weather data compiled into a typical year to model operation of the computer generated building from midnight on 1st January to midnight on 31st December. CIBSE has produced a number of test years to use, including predicted climate change effects 10

Annual energy (at point of use) and CO2 output Gas19098 MWh = 68760 GJ Electricity16169 MWh = 58208 GJ (of which 2232 is from CHP) Annual Carbon Emissions (allowing for CHP benefit) Gas = 3,850,000kg Electricity = 8,3789,24kg TOTAL12,228,924 = 12,229, Metre Tonnes C02. This equates to 6473 kg C02/100m3 The tables summarise the energy used in the hospital on a monthly basis under the following headings:- Heating Cooling Humidification De-humidification Ventilation re - heating Ventilation re cooling Hot Water Catering Electrical Power incl. medical equipment Lifts Lighting 11

GJ/m3 CONCLUSIONS Total Energy Total Area 35267 69961 JOIN THE CIBSE HEALTHCARE GROUP JOIN ASHRAE TC 9.6 kwh/m2 504 GJ/100m3 67.04 12