Start with ME. LEAVE A LEGACY OF EXCELLENT OUTCOMES WITH PEACE OF MIND. TECNIS MONOFOCAL IOL WITH TECNIS itec PRELOADED DELIVERY SYSTEM

Similar documents
IT S A GLOBAL LEADER. IT S PROVEN.

MATERIAL & DESIGN MAKE THE DIFFERENCE

Introducing the envista IOL. Dr Kerrie Meades PersonalEYES Pty Ltd

Instructions For Use 1stQ Basis IOL - Preloaded

The effects of three-piece or single-piece acrylic intraocular lens implantation on posterior capsule opacification

Intraocular Lens (IOL): Market Shares, Strategies, and Forecasts, Worldwide, Nanotechnology, 2013 to 2018

Laser Cataract Refractive Surgery. Robert Maloney, MD

Build With VICTUS. Build Your Patient Offerings. Build Your Premium Practice.

Considerations in IOL standards and design:

Build With VICTUS. Build Your Patient Offerings. Build Your Premium Practice.

CHECK OUT THESE KEY TOPICS

CAUTION: U.S. Federal law restricts this device to sale by or on the order of a licensed physician.

Minimally Invasive Glaucoma Surgical Procedures: Should I Incorporate Them Into My Practice?

TRELLIS COLLAGEN RIBBON

The IVIS Suite is an integrated ensemble of hardware and software devices, individually named Precisio, pmetrics, Cipta, Clat, RoMa and Ires.

A systematic approach to micro-coaxial phaco surgery. What the science says

Processed from Donated Human Tissue by LifeCell Corporation for KCI USA, Inc.

Femtosecond laser assisted cataract surgery

Targeting Better Visual Outcomes

Advanced Lasers. and Imaging for Cataract Surgery

Q: How can medical molders help device designers achieve compliance with the upcoming UDI rule? Fox:

MYTH BUSTERS. Cataract Refractive Surgery. Optimizing Procedures with the LenSx Laser. Published as a promotional supplement to SEPTEMBER 2015

LABORATORY SCIENCE. Biocompatibility of intraocular lens power adjustment using a femtosecond laser in a rabbit model

03/25/2014 FSL CATARACT SURGERY: CHANGES IN THE CLINIC AND ASC. Cataract Surgery Today. Financial Disclosure. Agenda: Laser Cataract Surgery

get more out of life. It s the value of professional advice.

Assessment of a new hydrophilic acrylic supplementary IOL for sulcus fixation in pseudophakic cadaver eyes

Repliform. Tissue Regeneration Matrix. Instructions for Use. Distributed by:

ISHE Issues. In this Issue: RTLS Location Accuracy and Its Affect on Hospital ROI

Guide for Cleaning, Sterilization and Storage of Introducers for Caldera Medical Implants

MITRAL VALVE REPAIR BACKGROUND

JEFFERIES HEALTHCARE CONFERENCE

Entellus Medical Sinuscope INSTRUCTIONS FOR USE

Innovations in Torsional Phaco and Micro-Coaxial Technologies

CapSure Permanent Fixation System

ROUTINE SPECIMEN COLLECTION BY SPECIMEN TYPE

Cataract is a consequence of the ageing of the lens and is the

Each year, the ASCRS Clinical

Supercritical Drug Impregnation onto Intraocular Lenses Abir BOULEDJOUIDJA a, Yasmine MASMOUDI a, *, Baoguang JIANG b,c,wei HE b,c, Elisabeth BADENS a

DuraGen Secure. Dural Regeneration Matrix

MEL 90 EXCIMER LASER. Proven experience and exciting advancement intelligently combined. Supplement to July/August 2014

Comprehensive Solutions

A Legacy of Serving the Surgical Community

What is in a posterior chamber intraocular lens? A review of the basic properties, materials and designs

The LenSx Laser COVER STORY

CHECK OUT THESE KEY TOPICS

Growth Fuel Rethinking trade spending in consumer products

SMALL-INCISION surgery for phacoemulsification

RapidPort EZ Port Applier DIRECTIONS FOR USE (DFU)

The heyelight in ophthalmic surgery MEGATRON

H5NA 04 (SCDHSC 0021) Support Effective Communication

H5NG 04 (SCDHSC0027) Support Individuals in Their Daily Living

Guidelines for the use of blood warming devices(aabb) Reference: 2002 AABB

Ask your surgeon for more information about Natrelle and visit GummyImplants.com

Infor Supply Chain Execution for Chemicals

Customizable VAD Power & Control Technology

Early Adopters Experiences With Laser Cataract Surgery

ALLODERM SELECT ALLODERM SELECT RESTORE

A PROGRESSIVE LEGACY OF PRECISION PERFORMANCE

The Integration and Application of ISO 9001 and the NIAHO Requirements In Medical Equipment Management

Products and Guidelines for Enhanced Office Safety

WHERE WILL THE WORKFORCE MOBILITY REVOLUTION TAKE YOU?

BRIC Surgical Sutures Market Outlook to 2020

Product Catalog (US) Conventional Needles I.V. Catheters Micro-Collection Products Safety Products Winged Infusion Sets

The technologies behind next-gen neuromodulation devices

MIIG INJECTABLE Graft The following languages are included in this packet:

IMAGINE IT. BUSINESS TRANSFORMATION. REAL CUSTOMER RETURNS. Done. Imagine it

Overcome inventory management challenges with our comprehensive suite of solutions

ISO Ophthalmic optics Contact lenses and contact lens care products Guidance for clinical investigations

Stericool H 2 O 2. plasma sterilizers Affordable low temperature solution

Image guided therapy. Azurion 7. With Azurion, performance and superior care become one

Review Article. Toxic anterior segment syndrome Moudgil T 1, Bansal Y 2

Product Catalog (Canada) Conventional Needles I.V. Catheters Micro-Collection Products Safety Products Winged Infusion Sets

Instructions for Use Reprocessed Ethicon ENDOPATH XCEL TM Dilating Tip Trocar with OPTIVIEW Technology

Scrum & Business Intelligence

Why Do I Need an Equipment Planner?

Frequently Asked Questions 01. Why do I see prices for some items and not others? How do I get pricing on items that I want to buy?

Getinge da Vinci Solution

Instructions for Use Reprocessed Ethicon ENDOPATH XCEL TM Universal Trocar Stability Sleeve. Reprocessed Device for Single Use.

Putting Workforce Analytics to Work: Achieving Objectives and Realizing Outcomes

MAKING PEOPLE S LIVES HEALTHIER, SAFER AND MORE FULFILLING.

Winning in Retail With RFID: Today and Tomorrow SML RFID is a division of SML Group Limited

MODEL EXPOSURE CONTROL PLAN

Meaningful Use - Stage 2 scorecard (in RevolutionEHR: Reports > Administration > Providers > Meaningful Use - Stage 2)

Inventory Control Maturity Continuum

Cranio-caudal Fixation Unit CC-GE MR10063-CC-GE

RIGID ENDOSCOPE OPERATING INSTRUCTIONS

MicroFunnel Filter Funnels

Platelet Concentrate in Total Knees BIOLOGICS. This brochure is for International use only. It is not for distribution in the United States.

Viscoelastics in Ophthalmic Surgery

Strategic Plan. Uniting to care & cure

Symposium INTERNATIONAL SCIENTIFIC SYMPOSIUM: WHAT S NEW IN REFRACTIVE EYE SURGERY

EyeGate Pharmaceuticals, Inc.

in Ultrasound-guided breast biopsy

Meeting the Challenges of Designing Medical Devices for Minimally Invasive Surgery

MedSC 2014 Spring Meeting. Managing Field and Consignment Inventory. June 4, 2014

Transcription:

LEAVE A LEGACY OF EXCELLENT OUTCOMES WITH PEACE OF MIND. Start with ME. TECNIS itec PRELOADED DELIVERY SYSTEM INDICATIONS: AMO TECNIS 1-Piece Lenses are indicated for the visual correction of aphakia in adult patients in whom a cataractous lens has been removed by extracapsular cataract extraction. These devices are intended to be placed in the capsular bag. See Indications and Important Safety Information on page 16.

THE LEGACY YOU LEAVE IS THE LIFE YOUR PATIENTS LIVE. And it begins with your choice. The IOL you choose is the one thing left behind after cataract surgery. It s the vision your patients take with them. It s also your confidence in the operating room. With the TECNIS Monofocal 1-Piece IOL and TECNIS itec Preloaded Delivery System, you can give your patients the sharpest vision, enhanced functionality and long-term sustainability and give yourself peace of mind by having safety and efficiency in every procedure. CHOOSE THE THE FOR: SHARPEST VISION ENHANCED FUNCTIONALITY LONG-TERM SUSTAINABILITY SAFETY & EFFICIENCY The sharpest vision and excellent acuity Enhanced functionality and outstanding low-light performance Long-term sustainability backed by sophisticated lens material Maximized patient safety and cost-effective efficiency pg 2

THE LENS YOU TRUST, PRELOADED FOR SAFETY AND EFFICIENCY. Add proven optical excellence and controlled, touch-free IOL delivery to your everyday procedures with the TECNIS Monofocal 1-Piece IOL, available with the TECNIS itec Preloaded Delivery System. Excellent outcomes for life Safety and efficiency now come preloaded pg 3

SHARPEST VISION LEAVE A LEGACY OF EXCELLENT OUTCOMES. Even the best surgical technique can t compensate for an inferior IOL. So when it comes to cataract procedures, give your patients a lens you can trust. The TECNIS Monofocal 1-Piece IOL is engineered for a higher standard of optical excellence so you can leave each patient with the sharp, high-quality vision they deserve. 20/16 or better visual acuity* in 70 % of patients. 1 20/20 or better visual acuity* in 96 % of patients. 1 *Best corrected binocular distance. pg 4

OUTSTANDING IMAGE CONTRAST Every patient wants to see extraordinary results, even from a monofocal lens. The TECNIS Monofocal 1-Piece IOL delivers the sharpest vision so you can leave a legacy that s anything but ordinary. Reduces chromatic aberration to maintain excellent image contrast 2 Corrects spherical aberration to essentially zero for outstanding visual performance 2 BEST-FOCUS MTF** 3 MTF at 50 c/mm 0.60 0.50 0.40 0.30 0.20 BEST-FOCUS MTF White Light MTF (50 c/mm) 14% 35% 14 35 % improved image contrast compared to another leading IOL 3 0.10 0.00 3 mm 5 mm Pupil Size TECNIS Monofocal (ZCB00) AcrySof (SN60WF) **Modular Transfer Function (MTF) is a measure of the amount of contrast transferred by the optics in a visual system. The higher the MTF value, the more contrast transferred to the image, resulting in higher image contrast. pg 5

ENHANCED FUNCTIONALITY LEAVE A LEGACY OF LIVING. Your legacy is your patients vision but also all the things it empowers them to do. Optimized for peak functional vision, TECNIS IOLs deliver high-quality, real-world performance so your patients can get back to their daily activities, even in low-light conditions. EXCELLENT LOW-LIGHT PERFORMANCE The TECNIS Monofocal 1-Piece IOL delivers improved patient safety under low-visibility conditions for driving and beyond. 4 TECNIS IOLs are likely to have meaningful safety benefits for elderly drivers as well as drivers and pedestrians sharing the road. 4 The IOLs improve functional vision, which can increase patient safety in other low-visibility situations as well. 4 *As compared to AcrySof IQ IOL. pg 6

35 % improvement in image contrast with large pupil (5 mm)* 3 pg 7

LONG-TERM SUSTAINABILITY LEAVE A LASTING LEGACY. Your patients sight is everything to them and they trust you to deliver results that are just as incredible tomorrow as they are today. TECNIS IOLs are made with a special material not associated with glistenings, so you can deliver excellent clarity. Give each patient excellent, enduring vision with a lens that s built to last. NOT ASSOCIATED WITH GLISTENINGS Glistenings can have a negative impact on your patient s vision by causing light scatter. This can mean a reduction in image contrast. 6,7 DARK FIELD IMAGES OF COMPETITOR IOL 7 10X 40X pg 8

TECNIS IOLs are made using a sophisticated material that is not associated with glistenings, unlike another leading IOL. 5-10 pg 9

LEAVE A LEGACY THAT DELIVERS. TECNIS itec Preloaded Delivery System Your outcomes come down to the lens you choose to leave behind and the way you deliver it. Start your legacy of excellent outcomes with the TECNIS Monofocal 1-Piece IOL, available with the TECNIS itec Preloaded Delivery System for sterile, controlled and touch-free IOL delivery. 11 PRELOADED IOL Conveniently loaded with the TECNIS Monofocal 1-Piece IOL PATIENT-FRIENDLY MATERIAL Not made with natural rubber latex FULL DIOPTER RANGE Lenses from +5.0 D to +34.0 D in 0.5 D steps PLUNGER MARKINGS Clear guidance to ensure consistent delivery BEVEL TIP Planar delivery via 2.2 mm 2.4 mm incision across all diopters CLEAR CARTRIDGE Visual check of IOL and OVD PRODUCT LABELING Verification of model and power prior to implantation SCREW-STYLE INSERTION MECHANISM Consistent, controlled advance and delivery pg 10

SAFETY & EFFICIENCY PREDICTABILITY FOR YOUR PROCEDURE. Your legacy begins with the IOL, so choose a delivery method preloaded for safety and efficiency. The TECNIS itec Preloaded Delivery System helps protect your patients by minimizing the risk of infection and inflammation and gives you the assurance of highly controlled, predictable delivery. MINIMIZE INFECTION RISK Support excellent outcomes in every procedure with a single-use system designed to maximize patient safety through minimal infection risk. MINIMIZE THE RISK OF INFECTION AND INFLAMMATION associated with contamination 12 ELIMINATE IOL TOUCHES 12 there s no need to directly touch the lens outside of the eye ELIMINATE LOADING ERRORS WARNINGS: When used according to the Directions for Use, the TECNIS itec Preloaded Delivery System minimizes the risk of infection and/or inflammation associated with contamination. The reuse/resterilization/reprocessing of AMO single-use devices may result in physical damage to the medical device, failure of the medical device to perform as intended, and patient illness or injury due to infection, inflammation, and/or illness due to product contamination, transmission of infection, and lack of product sterility. See Indications and Important Safety Information continued on page 16. pg 11

SAFETY & EFFICIENCY PRODUCTIVITY FOR YOUR PRACTICE. The TECNIS Monofocal 1-Piece IOL now comes preloaded, and that can mean big things for your practice. The TECNIS itec Preloaded Delivery System eliminates the need for injectors and separate cartridge inventories, which streamlines your inventory management. And without the need to load manually, you ll have faster, more efficient procedures 10 and more time to focus on your patients. MEAN TOTAL CASE TIMES BY STUDY SITE 10 MEAN TOTAL CASE TIMES BY STUDY SITE Up to 12 % reduction in total case time* 12 Reduced Total Case Time: In study sites across the world, the TECNIS itec Preloaded Delivery System led to statistically significant reduction in total case times. Total Case Time Min. (mean) 35 30 25 20 15 10 5 0-12% -6.2% Canada France U.S.A. -9.4% Manual itec Study Sites *Individual results may vary. pg 12

IMPROVED CASE THROUGHPUT With an additional monofocal cataract case per surgery day, it was estimated that a relatively low-volume, one-or setup could increase annual throughput by 36 cases or 9.9% while moderate- to high-volume, two-or sites could increase annual throughput by 90 96 cases or 4 6% annually. 13 TOTAL SURGEON LENS TIMES BY STUDY SITE** 10 Up to 44 % reduction in total surgeon lens time* 10 Reduced Total Surgeon Lens Time: TECNIS itec Preloaded Delivery System reduces serial steps and eliminates manual lens loading, resulting in significant total surgeon lens time reduction across study sites. 1 additional surgery per day 13 Total Surgeon Time Min. (mean) 2:00 1:45 1:30 1:15 1:00 0:45 0:30 0:15-43.7% -31.9% -17.4% Manual itec Up to 10 % increase in total annual throughput of cases 12 **Total surgeon lens time is defined as the time the surgeon spends loading, inserting, and positioning the lens in the eye. 0 Canada France U.S.A. Study Sites pg 13

TECHNICAL SPECIFICATIONS TECNIS itec Preloaded Delivery System (PCB00) Incision Size: Delivery System: Injector Type: 2.2 mm 2.4 mm Screw-style Disposable TECNIS Monofocal 1-Piece IOL (ZCB00) OPTIC CHARACTERISTICS Power Range: +5.0 D to +34.0 D in 0.5 diopter increments Diameter: 6.0 mm Shape: Biconvex, anterior aspheric surface, square optic edge Material: UV-blocking hydrophobic acrylic Refractive Index: 1.47 Edge Design: ProTEC frosted, continuous 360 posterior square edge BIOMETRY A-constant: HAPTIC CHARACTERISTICS Overall Length: Style: Material: Design: 119.3 (Optical Biometry)* 118.8 (Ultrasound Biometry-Contact) 13.0 mm C UV-blocking hydrophobic acrylic Haptics offset from optic pg 14 *Derived from clinical evaluation results of the TECNIS 1-Piece IOL platform. Value theoretically derived for a typical 20.0 D lens. Johnson & Johnson VISION recommends that surgeons personalize their A-constant based on their surgical techniques and equipment, experience with the lens model, and postoperative results. REFERENCES 1. Data On File, Abbott Medical Optics Inc., 2015. 2. Data On File, Abbott Medical Optics Inc., 2015. 3. Data On File, Abbott Medical Optics Inc., 2015. 4. TECNIS Foldable Posterior Chamber Intraocular Lens [package insert]. Santa Ana, Calif. Abbott Medical Optics Inc. 5. Data On File, Abbott Medical Optics Inc., 2013. 6. Van der Mooren M, Franssen L, Piers P. Effects of glistenings in intraocular lenses. Biomed Opt Express. 2013 Jul 11;4(8):1294-3041. 7. Nagata M, et al. Clinical evaluation of the transparency of hydrophobic acrylic intraocular lens optics. J Cataract Refract Surg. 2010 Dec;36(12):2056-60. 8. Christiansen G, et al. Glistenings in the AcrySof intraocular lens: pilot study. J Cataract Refract Surg 2001;27:728-33. 9. Gunenc U, et al. Effects on visual function of glistenings and folding marks in AcrySof intraocular lenses. J Cataract Refract Surg. 2001; 27(10):1611-1614. 10. Colin J, et al. Incidence of glistenings with the latest generation of yellow-tinted hydrophobic acrylic intraocular lenses. J Cataract Refract Surg. 2012; 38:(7)1140-1146. 11. TECNIS Monofocal IOL with itec Preloaded Delivery System [package insert]. Santa Ana, Calif. Abbott Medical Optics Inc. 12. Data On File, Abbott Medical Optics Inc., 2015. 13. Data On File, Abbott Medical Optics Inc., 2015.

WHAT WILL YOUR LEGACY BE? Your patients vision is only as good as the IOL you leave behind. Your legacy isn t decided after the procedure is done. It begins with a choice. Your patients expect remarkable vision, delivered both quickly and with minimized risk of infection and inflammation, 9 so make sure your IOL and delivery method are up to the challenge. Choose to back your outcomes with the TECNIS Monofocal 1-Piece IOL and TECNIS itec Preloaded Delivery System for the sharpest vision, highly functional and sustainable performance with safety and efficiency in every procedure. Don t wait to leave a legacy of excellent outcomes with peace of mind. Start now with the TECNIS Monofocal 1-Piece IOL and TECNIS itec Preloaded Delivery System.

INDICATIONS AND IMPORTANT SAFETY INFORMATION FOR THE TECNIS 1-PIECE MONOFOCAL IOL Rx Only ATTENTION: Reference the Directions for Use for a complete listing of Indications and Important Safety Information. INDICATIONS: AMO TECNIS 1-Piece Lenses are indicated for the visual correction of aphakia in adult patients in whom a cataractous lens has been removed by extracapsular cataract extraction. These devices are intended to be placed in the capsular bag. PRECAUTIONS: Do not resterilize the lens. Most sterilizers are not equipped to sterilize the soft acrylic material without producing undesirable side effects. Do not soak or rinse the intraocular lens with any solution other than sterile balanced salt solution or sterile normal saline. Do not store the lens in direct sunlight or at a temperature greater than 113 F (45 C). Do not autoclave the intraocular lens. Please refer to the specific instructions for use provided with the insertion instrument or system for the amount of time the IOL can remain folded before the IOL must be discarded. When the insertion system is used improperly, the haptics of the TECNIS 1-Piece Lens may become damaged. WARNINGS: Physicians considering lens implantation should weigh the potential risk/benefit ratio for any conditions described in the TECNIS 1-Piece IOL Directions for Use that could increase complications or impact patient outcomes. These conditions include recurrent severe anterior or posterior segment inflammation or uveitis; patients in whom the intraocular lens may affect the ability to observe, diagnose, or treat posterior segment diseases; surgical difficulties at the time of cataract extraction, which may increase the potential for complications (e.g., persistent bleeding, significant iris damage, uncontrolled positive pressure or significant vitreous prolapse or loss); a compromised eye due to previous trauma or developmental defects in which appropriate support of the IOL is not possible; circumstances that would result in damage to the endothelium during implantation; suspected microbial infection; or patients in whom neither the posterior capsule nor the zonules are intact enough to provide support for the IOL. Children under the age of 2 years are not suitable candidates for intraocular lenses. The TECNIS 1-Piece IOL should not be placed in the ciliary sulcus. ADVERSE EVENTS: In 3.3% of patients, reported adverse events of cataract surgery with the 1-Piece IOL included macular edema. Other reported reactions occurring in less than 1% of patients were secondary surgical intervention (pars plana vitrectomy with membrane peel) and lens exchange (due to torn lens haptic). IMPORTANT SAFETY INFORMATION FOR THE TECNIS MONOFOCAL 1-PIECE IOL WITH Rx Only ATTENTION: Reference the Directions for Use for a complete listing of Indications and Important Safety Information. INDICATIONS: The TECNIS 1-Piece Lens is indicated for the visual correction of aphakia in adult patients in whom a cataractous lens has been removed by extracapsular cataract extraction. These devices are intended to be placed in the capsular bag. WARNINGS: Physicians considering lens implantation under any of the following circumstances should weigh the potential risk/benefit ratio: Patients with recurrent severe anterior or posterior segment inflammation or uveitis; patients in whom the intraocular lens may affect the ability to observe, diagnose or treat posterior segment diseases; surgical difficulties at the time of cataract extraction, which may increase the potential for complications (e.g., persistent bleeding, significant iris damage, uncontrolled positive pressure or significant vitreous prolapse or loss); a compromised eye due to previous trauma or developmental defect in which appropriate support of the IOL is not possible; circumstances that would result in damage to the endothelium during implantation; suspected microbial infection; patients in whom neither the posterior capsule nor the zonules are intact enough to provide support for the IOL; children under the age of 2 years are not suitable candidates for intraocular lenses. Do not attempt to disassemble, modify or alter this device or any of its components, as this can significantly affect the function and/or structural integrity of the design. Use of methylcellulose viscoelastics is not recommended as they have not been validated for use with the TECNIS itec Preloaded Delivery System. Do not implant the lens if the rod tip does not advance the lens or if it is jammed in the cartridge. Do not push the plunger forward to fully advance the lens until ready for lens implantation. Discard the device if the lens has been fully advanced for more than 1 minute. AMO single-use medical devices are labeled with instructions for use and handling to minimize exposure to conditions which may compromise the product, patient, or the user. The TECNIS 1-piece IOL should be placed entirely in the capsular bag. Do not place the lens in the ciliary sulcus. PRECAUTIONS: Do not resterilize the lens or the TECNIS itec Preloaded Delivery System. Most sterilizers are not equipped to sterilize the soft acrylic material and the preloaded inserter material without producing undesirable side effects. Do not store the device in direct sunlight or at a temperature under 5 C (41 F) or over 35 C (95 F). Do not autoclave the device. Do not advance the lens unless ready for lens implantation. The contents are sterile unless the package is opened or damaged. The recommended temperature for implanting the lens is at least 17 C. The combination of low operating room temperatures and high IOL diopter powers may require slower delivery. The use of viscoelastics is required when using the TECNIS itec Preloaded Delivery System. For optimal performance, use the AMO HEALON Family of Viscoelastics. The use of balanced salt solution alone is not recommended. Do not use if the TECNIS itec Preloaded Delivery System has been dropped or if any part was inadvertently struck while outside the shipping case. ADVERSE EVENTS: The most frequently reported adverse event that occurred during the clinical trial of the TECNIS 1-Piece IOL was cystoid macular edema, which occurred at a rate of 3.3%. Other reported events occurring in less than 1% of patients were secondary surgical intervention (0.8%, vitrectomy) and lens exchange (0.8%, due to torn lens haptic). TECNIS, TECNIS itec, and ProTEC are trademarks owned by or licensed to Abbott Laboratories, its subsidiaries or affiliates. AcrySof is a trademark owned by or licensed to Novartis AG Corp., its subsidiaries or affiliates. 2017 Abbott Medical Optics Inc. www.vision.abbott.us PP2017CT0398 TEC15-16