Table of Contents... 1, 2. (EF) Equipment Floor... VISR EF 102 Water Heater VISR EF 104 Chiller VISR EF 105 End Suction Pump...

Similar documents
Seismic Installation Manual

SECTION VIBRATION CONTROLS FOR HVAC PIPING AND EQUIPMENT

KINETICS Pipe & Duct Seismic Application Manual

SECTION HANGERS AND SUPPORTS FOR PLUMBING

SECTION VIBRATION ISOLATION

SECTION VIBRATION ISOLATION FOR PLUMBING PIPING AND EQUIPMENT

C. Concrete Inertia Bases: Drawings showing required concrete steel reinforcing, construction details, and dimensions.

SECTION SEISMIC CONTROL OSHPD

SEISMIC RESTRAINTS Multi-Directional Bracing For Electrical Conduit, Cable Tray And Mechanical Piping Systems

DARTMOUTH COLLEGE DESIGN September 15, 2004 &CONSTRUCTION GUIDELINES

KINETICS Seismic & Wind Design Manual Section D9.0

A. Pipe Supports: ANSI B 31.1, Power Piping. B. Automatic Sprinkler Pipe Supports: Refer to Section

SECTION HANGERS AND SUPPORTS FOR PLUMBING PIPING AND EQUIPMENT. A. ASME B31.1 (American Society of Mechanical Engineers) - Power Piping

B. American Society for Testing and Materials: 1. ASTM F708 - Standard Practice for Design and Installation of Rigid Pipe Hangers.

SECTION HANGERS AND SUPPORTS FOR HVAC PIPING AND EQUIPMENT

1.2 ACTION AND INFORMATIONAL SUBMITTALS.1 Provide submittals in accordance with Section Submittal Procedures.

Seismic Installation Manual

UNIFIED FACILITIES GUIDE SPECIFICATIONS

SECTION VIBRATION AND SEISMIC CONTROLS FOR ELECTRICAL SYSTEMS

SECTION HANGERS AND SUPPORTS FOR PLUMBING PIPING AND EQUIPMENT

KINETICS Pipe & Duct Seismic Application Manual

Seismic Installation Manual

DIVISION 15-MECHANICAL SECTION SUPPORTS AND ANCHORS PN PART 1 - GENERAL 1.01 SECTION INCLUDES. A. Pipe and equipment support systems.

NORTHWESTERN UNIVERSITY PROJECT NAME JOB #

Seismic Restraints. Cent-R-Rail Supplement* SYSTEMS THAT MAKE SENSE

OSU PROJECT NO PAGE 1 02 NOV 2006 SECTION SUPPORTS AND ANCHORS

FEDERAL EMERGENCY MANAGEMENT AGENCY FEMA 414/January 2004 INSTALLING SEISMIC RESTRAINTS FOR DUCT AND PIPE

SECTION SEISMIC RESTRAINT REQUIREMENTS FOR NON-STRUCTURAL COMPONENTS REVISED PART 1 GENERAL 1.1 DESCRIPTION:

SECTION HANGERS AND SUPPORTS FOR ELECTRICAL SYSTEMS

SEISMIC CONTROL MEASURES By Richard Lévesque, ing., P.Eng., LEED AP

HANGERS AND SUPPORTS FOR HVAC PIPING AND EQUIPMENT SECTION HANGERS AND SUPPORTS FOR HVAC PIPING AND EQUIPMENT

NORTH HARRIS COUNTY REGIONAL WATER AUTHORITY PIPE HANGERS, Section PIPE HANGERS, SUPPORTS, AND RESTRAINTS

2005 Seismic Bracing System. Kindorf Modular Metal Framing

SECTION HANGERS AND SUPPORTS FOR HVAC PIPING AND EQUIPMENT

Fig. 1 - Standard Clevis Hanger

SECTION HANGERS AND SUPPORTS FOR ELECTRICAL SYSTEMS. 1. Hangers and supports for electrical equipment and systems.

SECTION HANGERS AND SUPPORTS FOR PLUMBING PIPING AND EQUIPMENT

1.2 DEFINITIONS, REFERENCES, AND OVERALL STANDARDS Follow 07500

Large cable sizes stronger than pipe/strut

SECTION VIBRATION ISOLATION AND SEISMIC RESTRAINT

SECTION VIBRATION AND SEISMIC CONTROL FOR PLUMBING

SECTION HANGERS AND SUPPORTS FOR PLUMBING PIPING AND EQUIPMENT

Structural Tests and Special Inspections Form. Inspection of Fabricators (1704.2)

SECTION HANGERS AND SUPPORTS FOR PLUMBING PIPING AND EQUIPMENT

REV. 9/08. Mounting Structure PRE-INSTALLATION GUIDE for Ergon Skybooms

Smarter. Safer. Leaner.

Materials Carbon Steel is used in the manufacturing of riser and pipe clamps. Stainless Steel and other materials are available.

SECTION HANGERS AND SUPPORTS FOR PLUMBING PIPING AND EQUIPMENT

IBC Compliant Seismic Rated Isolators

KINETICS Pipe & Duct Seismic Application Manual

1. Hangers and supports for electrical equipment and systems. 2. Construction requirements for concrete bases.

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017

TOLCO Fire Protection Support Systems. Pipe Hangers Supports Seismic Bracing. UL Listed FM Approved for Fire Sprinkler Installations

Pre-Fabricated Roof Curbs

E. Manufacturers Standardization Society of the Valve and Fittings Industry:

University of Delaware

HANGERS AND SUPPORTS FOR HVAC PIPING AND EQUIPMENT

UNIFIED FACILITIES GUIDE SPECIFICATIONS

UNIVERSITY SERVICES ANNEX James Madison University Harrisonburg, Virginia State Project Code: Architect s Project Number:

SECTION HANGERS AND SUPPORTS FOR PLUMBING PIPING AND EQUIPMENT

CITY OF LOS ANGELES CALIFORNIA

Fig Beam Clamp Retaining Strap (B-Line B3367)

SECTION HANGERS AND SUPPORTS FOR HVAC PIPING AND EQUIPMENT

VIBRATION TRANSMISSIBILITY CURVE FOR AN ISOLATED SYSTEM

SECTION PLATE CONNECTED WOOD TRUSSES

Daytona Beach Pier Building Renovation Jun 2010

SECTION HANGERS AND SUPPORTS PART 1 - GENERAL. A. Drawings and Division 1 Specification Sections, apply to this Section.


Flotation Docking Systems, Inc.

ROOFTOP EQUIPMENT Guide

SECTION COOLING TOWER

Installing Seismic Restraints for Electrical Equipment

SECTION HVAC DUCTS AND CASINGS

SECTION ROTARY SCREW WATER CHILLERS

SECTION NON-PENETRATING PORTABLE ROOFTOP SUPPORTS AND WALKWAYS. For best results, display hidden notes to specifier.

E. Manufacturers Standardization Society of the Valve and Fittings Industry:

SECTION NON-STRUCTURAL METAL FRAMING

Light-Metal Roof Edge, Raised

Standard Installation Fire Damper Models: 119, 119(F), 119(SS), D19

Suspension Systems for Acoustical Lay-in Ceilings Seismic Design Categories D, E & F

VMA C (Revision 2)

B-LINE SERIES. DURA-BLOK rooftop supports BRTS-17 DURA-BLOK. A complete rooftop support solution

WALL MOUNTED ARTICULATING JIB CRANE

Industry Standard Terms & Definitions Of The Steel Deck Institute

DDI + (DECK INSERT) Threaded Insert for Metal Deck

FIREPRO FIRE DUCT SYSTEMS Single layer fire protection for rectangular, circular and oval ducts.

TEST REPORT. Rendered to: SENTINEL FENCE AND RAIL. For: 120 in by 42 in Fully-Welded Aluminum Guardrail Assembly with Intermediate Support Post

Support Systems for Rooftop Building Services. ecosupportproducts.com. protect the roof. protect the warranty. protect the environment.

E-LINESEISMIC 2017/1. Seismic Bracing Systems

NUSIG / BADGER INDUSTRIES and ANVIL INTERNATIONAL LLC.,

B. Polyethylene samples shall be submitted for Owner approval of color and quality.

HILLSBOROUGH TOWNSHIP CODE ENFORCEMENT

Administrative Changes

Student Services & Classroom Addition

WIND SPEED AND DESIGN CRITERIA FOR FLEXIBLE FACE SIGNS CONSTRUCTED OF ABC EXTRUSIONS

DURA-BLOK Rooftop Supports

QuakeLoc. Seismic Cable Restraint Connector for piping, duct, electrical cable trays, and suspended equipment. MADE IN THE USA MADE IN THE USA

Item 442 Metal for Structures

SPECIFICATIONS - DETAILED PROVISIONS Section Stainless Steel Sluice Gates C O N T E N T S

Cantilevered Rail System

Transcription:

VISR Standard Details - TOC VISR-SD File No: T-VISR-SD-00 Supersedes: New Date: 6-Mar-204 Date: New VISR Standard Details: Table of Contents Table of Contents..., 2 (EF) Equipment Floor... VISR EF 0 Tank... 3 VISR EF 02 Water Heater... 4 VISR EF 03 AHU... 5 VISR EF 04 Chiller... 6 VISR EF 05 End Suction Pump... 7 VISR EF 06 Inline Pump... 8 VISR EF 07 Floor Mtd. Equip. (Generic)... 9 VISR EF 08 Gen Set... 0 VISR EF 09 Heat Exchanger... VISR EF 0 Cooling Tower... 2 VISR EF Air Compressor... 3 VISR EF 2 Vacuum Pump... 4 VISR EF 3 Transformer... 5 VISR EF 4 Double Suction Pump... 6 (ER) Equipment Roof... VISR ER 0 Cooling Tower... 7 VISR ER 02 RTU with VCR... 8 VISR ER 03 Fans... 9 VISR ER 04 Air Cooled Chiller... 20 VISR ER 05 Condensing Unit... 2 (ES) Equipment Suspended... VISR ES 0 Suspended Equipment (Generic)... 22 VISR ES 02 Inline Pump... 23 VISR ES 03 Axial Fan... 24 VISR ES 04 Air Separator... 25 VISR ES 05 Chilled Beam... 26 VISR ES 06 Unit Heater... 27 VISR ES 07 Kitchen Hood... 28 (EW) Equipment Wall...

VISR Standard Details - TOC VISR-SD File No: T-VISR-SD-00 Supersedes: New Date: 6-Mar-204 Date: New VISR EW 0 Panel Board... 29 VISR EW 02 Exp.Tank (small)... 30 (PF) Pipe Floor... VISR PF 0 Pipe Riser (spring)... 3 VISR PF 02 Pipe Riser (pad)... 32 VISR PF 03 Pipe Riser (pad)... 33 (PR) Pipe Roof... VISR PR 0... 34 (DR) Duct Roof... VISR DR 0... 35 (PS) Pipe Suspended... VISR PS 0... 36 (DS) Duct Suspended... VISR DS 0... 37 Disclaimers, Assumptions & Directive Statements....38

TANK RESTRAINT BRACKET FASTENED TO TANK SKIRT. V-A TYPE SRB ANCHOR PER SEISMIC CALCULATION 20 HOUSEKEEPING PAD TO BE DOWELED TO THE STRUCTURE AND SIZED TO ACCEPT SEISMIC ANCHORAGE PLAN VIEW. ALL PRODUCT SIZES AND CAPACITIES TO BE DETERMINED AFTER EQUIPMENT IS APPROVED AND CALCULATIONS HAVE BEEN PERFORMED. SEISMIC BRACING - FLOOR MOUNTED TANK VISR-EF-0

WH ANCHOR STRUT TO STRUCTURAL WALL PER SEISMIC CALCULATION WH STRUT STAND. ALL CONNECTIONS MADE WITH A307 BOLTS MIN. STRAP STRUT STRAP 2/3 HT. MIN. 2/3 HT. MIN. ANCHOR PER SEISMIC CALCULATION CROSS BRACE @ 35-55 ANGLE STRAP TO WRAP AROUND TANK STRAP TO WRAP AROUND TANK KICKER @ 35-55 ANGLE TO SLAB PLAN VIEW PLAN VIEW OPTION # - WALL ATTACHMENT OPTION #2 - STAND ATTACHMENT. THESE OPTIONS MAY REQUIRE ADDITIONAL BRACING FOR SEISMIC FORCES (Fp) GREATER THAN 500 LBS. 2. ALL PRODUCT SIZES AND CAPACITIES TO BE DETERMINED AFTER EQUIPMENT IS APPROVED AND CALCULATIONS HAVE BEEN PERFORMED. 3. REFERENCE PRODUCT DATA SHEETS FOR ADDITIONAL INFORMATION. SEISMIC BRACING - FLOOR MOUNTED WATER HEATER VISR-EF-02

RESTRAINT BRACKET FASTENED TO AHU BASE. V-A TYPE SRB WITH GROMMET WASHER FLEXIBLE CONNECTOR AT ALL PIPING CONNECTIONS ANCHOR PER SEISMIC CALCULATION HOUSEKEEPING PAD TO BE DOWELED TO THE STRUCTURE AND SIZED TO ACCEPT SEISMIC ANCHORAGE NEOPRENE PAD. V-A TYPE NSN. ALL PRODUCT QUANTITIES, SIZES AND CAPACITIES TO BE DETERMINED AFTER EQUIPMENT IS APPROVED AND CALCULATIONS HAVE BEEN PERFORMED. VIBRATION & SEISMIC CONTROL - FLOOR MOUNTED AHU VISR-EF-03

FLEXIBLE CONNECTOR AT PIPING CONNECTIONS FLEXIBLE CONNECTOR AT ALL PIPING CONNECTIONS ANCHOR PER SEISMIC CALCULATION WITH RUBBER GROMMET NEOPRENE PAD. V-A TYPE NSN HOUSEKEEPING PAD TO BE DOWELED TO THE STRUCTURE AND SIZED TO ACCEPT SEISMIC ANCHORAGE RESTRAINED SPRING ISOLATOR. V-A TYPE CSR/SCSR ANCHOR PER SEISMIC CALCULATION HOUSEKEEPING PAD TO BE DOWELED TO THE STRUCTURE AND SIZED TO ACCEPT SEISMIC ANCHORAGE OPTION # - NEOPRENE PAD ISOLATORS (GRADE) OPTION #2 - SPRING ISOLATORS (UPPER FLOORS). ALL PRODUCT QUANTITIES, SIZES AND CAPACITIES TO BE DETERMINED AFTER EQUIPMENT IS APPROVED AND CALCULATIONS HAVE BEEN PERFORMED. VIBRATION & SEISMIC CONTROL - FLOOR MOUNTED CHILLER VISR-EF-04

DOUBLE SPHERE NEOPRENE FLEX CONNECTOR WITH CONTROL UNITS. V-A TYPE NNDCU ANCHOR AND RUBBER WASHER WHEN SEISMIC RESTRAINT IS REQ'D PER CALCULATION NEOPRENE PAD. V-A TYPE NSN OPTION # - NEOPRENE PAD ISOLATORS (GRADE) DOUBLE SPHERE NEOPRENE FLEX CONNECTOR WITH CONTROL UNITS. V-A TYPE NNDCU CONCRETE INERTIA BASE V-A TYPE CIB OPEN SPRING ISOLATOR V-A TYPE FS OPTION #2 - SPRING ISOLATORS (UPPER FLOORS) DOUBLE SPHERE NEOPRENE FLEX CONNECTOR WITH CONTROL UNITS. V-A TYPE NNDCU ANCHOR PUMP TO BASE CONCRETE INERTIA BASE V-A TYPE CIB SEISMIC SPRING ISOLATOR V-A TYPE SFS HOUSEKEEPING PAD TO BE DOWELED TO THE STRUCTURE AND SIZED TO ACCEPT SEISMIC ANCHORAGE OPTION #3 - SEISMIC SPRING ISOLATORS (UPPER FLOORS). ALL PRODUCT QUANTITIES, SIZES AND CAPACITIES TO BE DETERMINED AFTER EQUIPMENT IS APPROVED AND CALCULATIONS HAVE BEEN PERFORMED. VIBRATION & SEISMIC CONTROL - END SUCTION PUMPS VISR-EF-05

DOUBLE SPHERE NEOPRENE FLEX CONNECTOR WITH CONTROL UNITS. V-A TYPE NNDCU PUMP STAND V-A TYPE SIPS ANCHOR AND RUBBER WASHER WHEN SEISMIC RESTRAINT IS REQ'D PER CALCULATION NEOPRENE PAD V-A TYPE NSN OPTION # - NEOPRENE PAD ISOLATORS (GRADE) DOUBLE SPHERE NEOPRENE FLEX CONNECTOR WITH CONTROL UNITS. V-A TYPE NNDCU PUMP STAND V-A TYPE SIPS CONCRETE INERTIA BASE V-A TYPE CIB OPEN SPRING ISOLATOR V-A TYPE FS OPTION #2 - SPRING ISOLATORS (UPPER FLOORS) DOUBLE SPHERE NEOPRENE FLEX CONNECTOR WITH CONTROL UNITS. V-A TYPE NNDCU PUMP STAND V-A TYPE SIPS CONCRETE INERTIA BASE V-A TYPE CIB SEISMIC SPRING ISOLATOR V-A TYPE SFS HOUSEKEEPING PAD TO BE DOWELED TO THE STRUCTURE AND SIZED TO ACCEPT SEISMIC ANCHORAGE OPTION #3 - SEISMIC SPRING ISOLATORS (UPPER FLOORS). ALL PRODUCT QUANTITIES, SIZES AND CAPACITIES TO BE DETERMINED AFTER EQUIPMENT IS APPROVED AND CALCULATIONS HAVE BEEN PERFORMED. VIBRATION & SEISMIC CONTROL - INLINE PUMPS VISR-EF-06

RESTRAINT BRACKET FASTENED TO UNIT BASE. V-A TYPE SRB WITH GROMMET WASHER. NOTE: RESTRAINT BRACKETS MAY NOT BE REQUIRED IF FACTORY MOUNTING HOLES ARE AVAILABLE AND ARE ADEQUATE. ANCHOR PER SEISMIC CALCULATION HOUSEKEEPING PAD TO BE DOWELED TO THE STRUCTURE AND SIZED TO ACCEPT SEISMIC ANCHORAGE. ALL PRODUCT QUANTITIES, SIZES AND CAPACITIES TO BE DETERMINED AFTER EQUIPMENT IS APPROVED AND CALCULATIONS HAVE BEEN PERFORMED. SEISMIC RESTRAINT - FLOOR MOUNTED EQUIPMENT VISR-EF-07

ANCHOR PER SEISMIC CALCULATION WITH RUBBER GROMMET RESTRAINED SPRING ISOLATOR. V-A TYPE CSR/SCSR NEOPRENE PAD. V-A TYPE NSN ANCHOR PER SEISMIC CALCULATION HOUSEKEEPING PAD TO BE DOWELED TO THE STRUCTURE AND SIZED TO ACCEPT SEISMIC ANCHORAGE HOUSEKEEPING PAD TO BE DOWELED TO THE STRUCTURE AND SIZED TO ACCEPT SEISMIC ANCHORAGE OPTION # - NEOPRENE PAD ISOLATORS (GRADE) OPTION #2 - SPRING ISOLATORS (ABOVE FLOORS). ALL PRODUCT QUANTITIES, SIZES AND CAPACITIES TO BE DETERMINED AFTER EQUIPMENT IS APPROVED AND CALCULATIONS HAVE BEEN PERFORMED. VIBRATION & SEISMIC CONTROL - GENSET VISR-EF-08

ANCHOR PER SEISMIC CALCULATION ANCHOR PER SEISMIC CALCULATION STAND BY OTHERS HOUSEKEEPING PAD TO BE DOWELED TO THE STRUCTURE AND SIZED TO ACCEPT SEISMIC ANCHORAGE HOUSEKEEPING PAD TO BE DOWELED TO THE STRUCTURE AND SIZED TO ACCEPT SEISMIC ANCHORAGE PLATE & FRAME SHELL &TUBE. ALL PRODUCT QUANTITIES, SIZES AND CAPACITIES TO BE DETERMINED AFTER EQUIPMENT IS APPROVED AND CALCULATIONS HAVE BEEN PERFORMED. VIBRATION & SEISMIC CONTROL - HEAT EXCHANGER VISR-EF-09

ANCHOR PER SEISMIC CALCULATION WITH RUBBER GROMMET NEOPRENE PAD. V-A TYPE NSN HOUSEKEEPING PAD TO BE DOWELED TO THE STRUCTURE AND SIZED TO ACCEPT SEISMIC/WIND ANCHORAGE FLEXIBLE CONNECTOR AT ALL PIPING CONNECTIONS. ALL PRODUCT QUANTITIES, SIZES AND CAPACITIES TO BE DETERMINED AFTER EQUIPMENT IS APPROVED AND CALCULATIONS HAVE BEEN PERFORMED. VIBRATION & SEISMIC CONTROL - COOLING TOWER VISR-EF-0

FLEXIBLE CONNECTOR ANCHOR AND RUBBER WASHER WHEN SEISMIC RESTRAINT IS REQ'D PER CALCULATION NEOPRENE PAD. V-A TYPE NSN HOUSEKEEPING PAD TO BE DOWELED TO THE STRUCTURE AND SIZED TO ACCEPT SEISMIC ANCHORAGE OPTION # - NEOPRENE PAD ISOLATORS (GRADE) FLEXIBLE CONNECTOR CONCRETE INERTIA BASE V-A TYPE CIB OPEN SPRING ISOLATOR V-A TYPE FS OPTION #2 - SPRING ISOLATORS (UPPER FLOORS) FLEXIBLE CONNECTOR CONCRETE INERTIA BASE V-A TYPE CIB SEISMIC SPRING ISOLATOR V-A TYPE SFS HOUSEKEEPING PAD TO BE DOWELED TO THE STRUCTURE AND SIZED TO ACCEPT SEISMIC ANCHORAGE OPTION #3 - SEISMIC SPRING ISOLATORS (UPPER FLOORS). ALL PRODUCT SIZES AND CAPACITIES TO BE DETERMINED AFTER EQUIPMENT IS APPROVED AND CALCULATIONS HAVE BEEN PERFORMED. 3. ANY PIPING CONNECTIONS SHALL BE MADE WITH FLEXIBLE HOSES WITH SUFFICIENT CAPACITY FOR DIFFERENTIAL MOVEMENT. VIBRATION & SEISMIC CONTROL - AIR COMPRESSOR VISR-EF-

ANCHOR AND RUBBER WASHER WHEN SEISMIC RESTRAINT IS REQ'D PER CALCULATION NEOPRENE PAD. V-A TYPE NSN HOUSEKEEPING PAD TO BE DOWELED TO THE STRUCTURE AND SIZED TO ACCEPT SEISMIC ANCHORAGE OPTION # - NEOPRENE PAD ISOLATORS (GRADE) CONCRETE INERTIA BASE V-A TYPE CIB OPEN SPRING ISOLATOR V-A TYPE FS OPTION #2 - SPRING ISOLATORS (UPPER FLOORS) CONCRETE INERTIA BASE V-A TYPE CIB SEISMIC SPRING ISOLATOR V-A TYPE SFS HOUSEKEEPING PAD TO BE DOWELED TO THE STRUCTURE AND SIZED TO ACCEPT SEISMIC ANCHORAGE OPTION #3 - SEISMIC SPRING ISOLATORS (UPPER FLOORS). ALL PRODUCT SIZES AND CAPACITIES TO BE DETERMINED AFTER EQUIPMENT IS APPROVED AND CALCULATIONS HAVE BEEN PERFORMED. 3. ANY PIPING CONNECTIONS SHALL BE MADE WITH FLEXIBLE HOSES WITH SUFFICIENT CAPACITY FOR DIFFERENTIAL MOVEMENT. VIBRATION & SEISMIC CONTROL - VACUUM PUMP VISR-EF-2

ANCHOR AND RUBBER WASHER WHEN SEISMIC RESTRAINT IS REQ'D PER CALCULATION NEOPRENE PAD. V-A TYPE NSN HOUSEKEEPING PAD TO BE DOWELED TO THE STRUCTURE AND SIZED TO ACCEPT SEISMIC ANCHORAGE. ALL PRODUCT SIZES AND CAPACITIES TO BE DETERMINED AFTER EQUIPMENT IS APPROVED AND CALCULATIONS HAVE BEEN PERFORMED. 3. ANY CONDUIT CONNECTIONS SHALL BE MADE WITH FLEXIBLE HOSES WITH SUFFICIENT CAPACITY FOR DIFFERENTIAL MOVEMENT. VIBRATION & SEISMIC CONTROL - TRANSFORMER VISR-EF-3

DOUBLE SPHERE NEOPRENE FLEX CONNECTOR WITH CONTROL UNITS. V-A TYPE NNDCU ANCHOR AND RUBBER WASHER WHEN SEISMIC RESTRAINT IS REQ'D PER CALCULATION NEOPRENE PAD. V-A TYPE NSN OPTION # - NEOPRENE PAD ISOLATORS (GRADE) DOUBLE SPHERE NEOPRENE FLEX CONNECTOR WITH CONTROL UNITS. V-A TYPE NNDCU CONCRETE INERTIA BASE V-A TYPE CIB OPEN SPRING ISOLATOR V-A TYPE FS HOUSEKEEPING PAD OPTION #2 - SPRING ISOLATORS (UPPER FLOORS) DOUBLE SPHERE NEOPRENE FLEX CONNECTOR WITH CONTROL UNITS. V-A TYPE NNDCU ANCHOR PUMP TO BASE CONCRETE INERTIA BASE V-A TYPE CIB SEISMIC SPRING ISOLATOR V-A TYPE SFS HOUSEKEEPING PAD TO BE DOWELED TO THE STRUCTURE AND SIZED TO ACCEPT SEISMIC ANCHORAGE OPTION #3 - SEISMIC SPRING ISOLATORS (UPPER FLOORS). ALL PRODUCT QUANTITIES, SIZES AND CAPACITIES TO BE DETERMINED AFTER EQUIPMENT IS APPROVED AND CALCULATIONS HAVE BEEN PERFORMED. VIBRATION & SEISMIC CONTROL - DOUBLE SUCTION PUMPS VISR-EF-4

ANCHOR ISOLATOR TO CONCRETE PER SEISMIC/WIND CALCULATION RESTRAINED SPRING ISOLATOR. V-A TYPE CSR/SCSR BOLT OR WELD ISOLATOR TO STEEL PER SEISMIC/WIND CALCULATION CONCRETE STRUCTURE STEEL STRUCTURE TO BE SIZED TO ACCEPT SEISMIC/WIND LOADS AND ANCHORAGE. BY OTHERS. FLEXIBLE CONNECTOR AT ALL PIPING CONNECTIONS CONCRETE PIERS TO BE SIZED TO ACCEPT SEISMIC/WIND LOADS AND ANCHORAGE. BY OTHERS FASTENED UNIT TO STEEL BASE PER SEISMIC/WIND CALCULATION FULL PERIMETER STEEL BASE FOR SEISMIC/WIND LOADS. V-A TYPE SB. ALL PRODUCT QUANTITIES, SIZES AND CAPACITIES TO BE DETERMINED AFTER EQUIPMENT IS APPROVED AND CALCULATIONS HAVE BEEN PERFORMED. 3. FLEX CONNECTIONS ARE REQUIRED ON ATTACHED PIPING. NOT SHOWN. VIBRATION & SEISMIC CONTROL - COOLING TOWER VISR-ER-0

RTU SEISMIC/WIND RATED SPRING ISOLATION CURB V-A TYPE VCR ATTACH UNIT TO CURB PER SEISMIC/WIND CALCULATION ROOFING ATTACH CURB TO STRUCTURE WITH CONCRETE ANCHOR PER SEISMIC/WIND CALCULATION CONCRETE ATTACHMENT ATTACH UNIT TO CURB PER SEISMIC/WIND CALCULATION ROOFING BOLT OR WELD CURB TO STRUCTURE PER SEISMIC/WIND CALCULATION STEEL ATTACHMENT. ALL PRODUCT SIZES AND CAPACITIES TO BE DETERMINED AFTER EQUIPMENT IS APPROVED AND CALCULATIONS HAVE BEEN PERFORMED. 3. ANY PIPING/DUCT CONNECTIONS SHALL BE MADE WITH FLEXIBLE CONNECTIONS WITH SUFFICIENT CAPACITY FOR DIFFERENTIAL MOVEMENT. 02 VIBRATION & SEISMIC CONTROL - RTU WITH VCR VISR-ER-02

ATTACH UNIT TO CURB PER SEISMIC/WIND CALCULATION MANUFACTURER'S CURB TO BE CAPABLE OF ACCEPTING SEISMIC/WIND LOADS ROOFING ATTACH CURB TO ROOF PER SEISMIC/WIND CALCULATION EXHAUST FAN WIRE/CABLE PER MANUFACTURER'S REQUIREMENTS ATTACH UNIT TO CURB PER SEISMIC/WIND CALCULATION MANUFACTURER'S CURB TO BE CAPABLE OF ACCEPTING SEISMIC/WIND LOADS ROOFING ATTACH CURB TO ROOF PER SEISMIC/WIND CALCULATION LAB EXHAUST FAN STEEL BASE V-A TYPE SB ATTACH UNIT TO BASE PER SEISMIC/WIND CALCULATION SEISMIC SPRING ISOLATOR V-A TYPE SFS ATTACH ISOLATORS TO RAIL PER SEISMIC/WIND CALCULATION ROOFING ATTACH RAIL TO ROOF PER SEISMIC/WIND CALCULATION RAIL TO BE CAPABLE OF ACCEPTING SEISMIC/WIND LOADS CENTRIFUGAL FAN. ALL PRODUCT SIZES AND CAPACITIES TO BE DETERMINED AFTER EQUIPMENT IS APPROVED AND CALCULATIONS HAVE BEEN PERFORMED. 3. ANY PIPING/DUCT CONNECTIONS SHALL BE MADE WITH FLEXIBLE CONNECTIONS WITH SUFFICIENT CAPACITY FOR DIFFERENTIAL MOVEMENT. VIBRATION & SEISMIC CONTROL - ROOF MOUNTED FANS VISR-ER-03

FLEXIBLE CONNECTOR AT ALL PIPING CONNECTIONS ANCHOR ISOLATOR TO CONCRETE PER SEISMIC/WIND CALCULATION RESTRAINED SPRING ISOLATOR. V-A TYPE CSR/SCSR BOLT OR WELD ISOLATOR TO STEEL PER SEISMIC/WIND CALCULATION CONCRETE STRUCTURE STEEL STRUCTURE TO BE SIZED TO ACCEPT SEISMIC/WIND LOADS AND ANCHORAGE. BY OTHERS. CONCRETE PIERS TO BE SIZED TO ACCEPT SEISMIC/WIND LOADS AND ANCHORAGE. BY OTHERS FASTEN UNIT TO ISOLATOR PER SEISMIC/WIND CALCULATION. ALL PRODUCT SIZES AND CAPACITIES TO BE DETERMINED AFTER EQUIPMENT IS APPROVED AND CALCULATIONS HAVE BEEN PERFORMED. 3. ANY PIPING CONNECTIONS SHALL BE MADE WITH FLEXIBLE CONNECTORS. 4. UNIT MANUFACTURER TO DETERMINE IF THE UNIT IS CAPABLE OF BEING POINT LOADED BY ISOLATORS. OTHERWISE A STEEL BASE MAY BE REQUIRED BETWEEN THE UNIT AND THE ISOLATORS. VIBRATION & SEISMIC CONTROL - AIR COOLED CHILLER VISR-ER-04

ANCHOR PER SEISMIC/WIND CALCULATION WITH RUBBER GROMMET NEOPRENE PAD. V-A TYPE NSN RAIL TO BE CAPABLE OF ACCEPTING SEISMIC/WIND LOADS ROOFING ATTACH RAIL TO ROOF PER SEISMIC/WIND CALCULATION OPTION # - NEOPRENE PAD ISOLATORS SEISMIC RUBBER MOUNT. V-A TYPE SRD ANCHOR PER SEISMIC/WIND CALCULATION WITH RUBBER GROMMET RAIL TO BE CAPABLE OF ACCEPTING SEISMIC/WIND LOADS ROOFING ATTACH RAIL TO ROOF PER SEISMIC/WIND CALCULATION OPTION #2 - SEISMIC RUBBER MOUNT. ALL PRODUCT SIZES AND CAPACITIES TO BE DETERMINED AFTER EQUIPMENT IS APPROVED AND CALCULATIONS HAVE BEEN PERFORMED. 3. ANY PIPING CONNECTIONS SHALL BE MADE WITH FLEXIBLE CONNECTORS. VIBRATION & SEISMIC CONTROL - CONDENSING UNIT VISR-ER-05

ISOLATOR WITH STOPWASHER WHEN REQUIRED ANCHOR TO ABOVE STRUCTURE PER SRK-AL 45-60 CABLE RESTRAINT TYPE SRK/BB ROD STIFFENER PER RS- OPTIONAL CABLE POSITIONS. CABLES MUST BE INSTALLED IN OPPOSING DIRECTIONS 45 (+/- 0 ) ATTACH SUPPORTING MEMBER TO EQUIPMENT PLAN VIEW. ALL PRODUCT SIZES AND CAPACITIES TO BE DETERMINED AFTER EQUIPMENT IS APPROVED AND CALCULATIONS HAVE BEEN PERFORMED. SEISMIC BRACING - SUSPENDED EQUIPMENT VISR-ES-0

ISOLATOR WITH STOPWASHER WHEN REQUIRED ANCHOR TO ABOVE STRUCTURE PER SRK-AL 45-60 CABLE RESTRAINT TYPE SRK/BB ROD STIFFENER PER RS- ATTACH CABLE RESTRAINT TO PIPE FLANGE OR PIPE CLAMP OPTIONAL CABLE POSITIONS. CABLES MUST BE INSTALLED IN OPPOSING DIRECTIONS 90 (+/- 5 ) PLAN VIEW. ALL PRODUCT SIZES AND CAPACITIES TO BE DETERMINED AFTER EQUIPMENT IS APPROVED AND CALCULATIONS HAVE BEEN PERFORMED. SEISMIC BRACING - SUSPENDED INLINE PUMP VISR-ES-02

ISOLATOR WITH STOPWASHER WHEN REQUIRED ANCHOR TO ABOVE STRUCTURE PER SRK-AL 45-60 CABLE RESTRAINT TYPE SRK/BB ROD STIFFENER PER RS- OPTIONAL CABLE POSITIONS. CABLES MUST BE INSTALLED IN OPPOSING DIRECTIONS 45 (+/- 0 ) PLAN VIEW. ALL PRODUCT SIZES AND CAPACITIES TO BE DETERMINED AFTER EQUIPMENT IS APPROVED AND CALCULATIONS HAVE BEEN PERFORMED. SEISMIC BRACING - SUSPENDED AXIAL FAN VISR-ES-03

ANCHOR TO ABOVE STRUCTURE PER SRK-AL 45-60 CABLE RESTRAINT TYPE SRK/BB ROD STIFFENER PER RS- ATTACH CABLE RESTRAINT TO PIPE FLANGE OR PIPE CLAMP OPTIONAL CABLE POSITIONS. CABLES MUST BE INSTALLED IN OPPOSING DIRECTIONS 90 (+/- 5 ) PLAN VIEW. ALL PRODUCT SIZES AND CAPACITIES TO BE DETERMINED AFTER EQUIPMENT IS APPROVED AND CALCULATIONS HAVE BEEN PERFORMED. SEISMIC BRACING - SUSPENDED AIR SEPARATOR VISR-ES-04

ANCHOR TO ABOVE STRUCTURE PER SRK-AL 45-60 ROD STIFFENER PER RS- CABLE RESTRAINT TYPE SRK/BB OPTIONAL CABLE POSITIONS. CABLES MUST BE INSTALLED IN OPPOSING DIRECTIONS 45 (+/- 0 ) PLAN VIEW. ALL PRODUCT SIZES AND CAPACITIES TO BE DETERMINED AFTER EQUIPMENT IS APPROVED AND CALCULATIONS HAVE BEEN PERFORMED. 3. ANY PIPING CONNECTIONS SHALL BE MADE WITH FLEXIBLE HOSES WITH SUFFICIENT CAPACITY FOR DIFFERENTIAL MOVEMENT. SEISMIC BRACING - CHILLED BEAM VISR-ES-05

ISOLATOR WITH STOPWASHER WHEN REQUIRED ANCHOR TO ABOVE STRUCTURE PER SRK-AL 45-60 CABLE RESTRAINT TYPE SRK/BB ROD STIFFENER PER RS- OPTIONAL CABLE POSITIONS. CABLES MUST BE INSTALLED IN OPPOSING DIRECTIONS 90 (+/- 5 ) PLAN VIEW (2 ROD ATTACHMENT) OPTIONAL CABLE POSITIONS. CABLES MUST BE INSTALLED IN OPPOSING DIRECTIONS 90 (+/- 5 ) PLAN VIEW (4 ROD ATTACHMENT). ALL PRODUCT SIZES AND CAPACITIES TO BE DETERMINED AFTER EQUIPMENT IS APPROVED AND CALCULATIONS HAVE BEEN PERFORMED. 3. ANY PIPING CONNECTIONS SHALL BE MADE WITH FLEXIBLE HOSES WITH SUFFICIENT CAPACITY FOR DIFFERENTIAL MOVEMENT. SEISMIC BRACING - SUSPENDED UNIT HEATER VISR-ES-06

OPTIONAL CABLE POSITIONS. CABLES MUST BE INSTALLED IN OPPOSING DIRECTIONS 35-60 CABLE RESTRAINT TYPE SRK/BB PLAN VIEW FASTEN UNIT TO WALL PER MANUFACTURER'S INSTRUCTIONS 35-60 ROD STIFFENER PER RS- SIDE VIEW. ALL PRODUCT SIZES AND CAPACITIES TO BE DETERMINED AFTER EQUIPMENT IS APPROVED AND CALCULATIONS HAVE BEEN PERFORMED. SEISMIC BRACING - SUSPENDED KITCHEN HOOD VISR-ES-07

ANCHOR UNIT TO STRUT WITH A307 BOLT OR EQUAL. INSTALL ISOLATION GROMMET WASHER WHEN REQUIRED BY SPECIFICATION. STRUT ANCHOR STRUT TO WALL PER SEISMIC CALCULATION SIDE VIEW PANEL BOARD (SMALL) - WALL MOUNTED ANCHOR UNIT TO STRUT WITH A307 BOLT OR EQUAL. INSTALL ISOLATION GROMMET WASHER WHEN REQUIRED BY SPECIFICATION. STRUT ANCHOR STRUT TO WALL PER SEISMIC CALCULATION SIDE VIEW PANEL BOARD (LARGE) - WALL MOUNTED. ALL PRODUCT QUANTITIES, SIZES AND CAPACITIES TO BE DETERMINED AFTER EQUIPMENT IS APPROVED AND CALCULATIONS HAVE BEEN PERFORMED. SEISMIC BRACING - PANEL BOARD VISR-EW-0

ANCHOR STRUT TO FULL HEIGHT WALL PER SEISMIC CALCULATION STRAP STRUT STRAP TIGHT TO TANK PLAN VIEW. ALL PRODUCT SIZES AND CAPACITIES TO BE DETERMINED AFTER EQUIPMENT IS APPROVED AND CALCULATIONS HAVE BEEN PERFORMED. SEISMIC BRACING - WALL MOUNTED EXPANSION TANK VISR-EW-02

PIPE RISER RISER CLAMP (BY OTHERS) SPRING ISOLATOR TYPE FS SEE DATA SHEETS FOR MORE INFORMATION CONCRETE SLAB SUPPORT STEEL FASTEN TO SUPPORT STEEL ANCHORING TO CONCRETE IS NOT REQ'D WHEN RISER IS SLEEVED THROUGH FLOOR INSULATION PIPE RISER W/ FS TYPE ISOLATORS SUPPORT DETAIL PIPE RISER RISER CLAMP WELDED TO ISOLATOR (BY OTHERS) SPRING ISOLATOR TYPE FST SEE DATA SHEETS FOR MORE INFORMATION CONCRETE SLAB SUPPORT STEEL FASTEN TO SUPPORT STEEL ANCHORING TO CONCRETE IS NOT REQ'D WHEN RISER IS SLEEVED THROUGH FLOOR INSULATION PIPE RISER W/ FST TYPE ISOLATORS SUPPORT DETAIL. REFERENCE SUBMITTAL DRAWINGS FOR RISER MOVEMENT CALCULATIONS, DIAGRAMS AND ISOLATOR LOCATIONS. 2. REFERENCE ISOLATOR DATA SHEETS FOR ADDITIONAL INFORMATION. PIPE RISER SUPPORT DETAIL - SPRING ISOLATORS VISR-PF-0

PIPE RISER RISER CLAMP WELDED TO ISOLATOR (BY OTHERS) PAD ISOLATOR TYPE NSNS SEE DATA SHEETS FOR MORE INFORMATION SUPPORT STEEL CONCRETE SLAB INSULATION PIPE RISER WITH PAD TYPE ISOLATORS SUPPORT DETAIL. REFERENCE SUBMITTAL DRAWINGS FOR RISER MOVEMENT CALCULATIONS, DIAGRAMS AND ISOLATOR LOCATIONS. 2. REFERENCE ISOLATOR DATA SHEETS FOR ADDITIONAL INFORMATION. PIPE RISER SUPPORT DETAIL - PAD ISOLATORS VISR-PF-02

PIPE RISER RISER CLAMP (BY OTHERS) RESTRAINED SPRING ISOLATOR TYPE SFS/CSR. SEE DATA SHEETS FOR MORE INFORMATION CONCRETE SLAB SUPPORT STEEL BOLT OR WELD TO SUPPORT STEEL ANCHOR TO CONCRETE INSULATION PIPE RISER ANCHOR W/ ISOLATORS DETAIL PIPE RISER RISER BRACKET WELDED TO ANCHOR PLATE (BY OTHERS) ANCHOR PLATE (BY OTHERS) SUPPORT STEEL ANCHOR TO CONCRETE BOLT OR WELD TO SUPPORT STEEL CONCRETE SLAB INSULATION PIPE RISER ANCHOR DETAIL. REFERENCE SUBMITTAL DRAWINGS FOR RISER MOVEMENT CALCULATIONS, DIAGRAMS AND ISOLATOR LOCATIONS. 2. REFERENCE ISOLATOR DATA SHEETS FOR ADDITIONAL INFORMATION. PIPE RISER SUPPORT DETAIL - ANCHORS VISR-PF-03 0

U-BOLT/STRAP (BY OTHERS) U-BOLT/STRAP (BY OTHERS) SEISMIC PIPE STAND V-A TYPE SPS/SPSA ROOF MEMBRANE SEISMIC PIPE STAND V-A TYPE SPS/SPSA ROOF MEMBRANE INSULATION INSULATION BACKING ANGLE (AS REQ'D) 2 PIECES PER STAND (BY OTHERS) A307 BOLT WITH DOUBLE NUT BACKING ANGLE (AS REQ'D) 2 PIECES PER STAND (BY OTHERS) A307 BOLT WITH DOUBLE NUT SIDE VIEW - SEISMIC PIPE STAND WITH METAL DECK ATTACHMENT SIDE VIEW - SEISMIC PIPE STAND WITH METAL DECK ATTACHMENT U-BOLT/STRAP (BY OTHERS) U-BOLT/STRAP (BY OTHERS) ADDED SUPPORT MEMBER (BY OTHERS) SEISMIC PIPE STAND V-A TYPE SPS/SPSA SEISMIC PIPE STAND V-A TYPE SPS/SPSA SEISMICALLY RATED CONCRETE ANCHOR BOLT SEISMICALLY RATED CONCRETE ANCHOR BOLT - SEISMIC PIPE STAND WITH CONCRETE ATTACHMENT - SEISMIC PIPE STAND WITH CONCRETE ATTACHMENT OPTION # - SINGLE PIPE OPTION # - SINGLE PIPE. REFERENCE SEISMIC CALCULATIONS FOR ANCHOR BOLT REQUIREMENTS. ROOFTOP PIPE RESTRAINT DETAIL VISR-PR-0

DUCT STRAP ATTACHED TO DUCT WITH #0 TEK SCREWS AT 6" O.C. ALL SIDES (BY OTHERS) SEISMIC STAND V-A TYPE SPS/SPSA ROOF MEMBRANE INSULATION BACKING ANGLE (AS REQ'D) 2 PIECES PER STAND (BY OTHERS) A307 BOLT WITH DOUBLE NUT SIDE VIEW - SEISMIC STAND WITH METAL DECK ATTACHMENT ATTACH DUCT TO SUPPORT MEMBER WITH #0 TEK SCREWS AT 6" O.C. (BY OTHERS) STRAP ATTACHED TO DUCT WITH #0 TEK SCREWS AT 6" O.C. ALL SIDES (BY OTHERS) ADDED SUPPORT MEMBER (BY OTHERS) SEISMIC STAND V-A TYPE SPS/SPSA SEISMICALLY RATED CONCRETE ANCHOR BOLT - SEISMIC STANDS WITH CONCRETE ATTACHMENT. REFERENCE SEISMIC CALCULATIONS FOR ANCHOR BOLT REQUIREMENTS. ROOFTOP DUCT RESTRAINT DETAIL VISR-DR-0 0

Detail - Transverse Cable Restraint BY CHECK SCALE 45-60 Max 4" Max 4" 45-60 45-60 45-60 45-60 45-60 45-60 45-60 Seismic Restraints - Piping SIDE VIEW HANGER ROD STIFFENER CLAMP WHERE REQ'D V-A TYPE VAC ANCHOR BOLT TO STRUCTURE SEISMIC RESTRAINT CABLE KIT V-A TYPE SRK/BB PIPE CLEVIS HANGER ISOMETRIC VIEW SIDE VIEW HANGER ROD STIFFENER CLAMP WHERE REQ'D ANCHOR BOLT V-A TYPE VAC TO STRUCTURE CLEVIS HANGER SEISMIC RESTRAINT CABLE KIT V-A TYPE SRK/BB PIPE PIPE CLAMP ISOMETRIC VIEW SIDE VIEW CLEVIS HANGER HANGER ROD ANCHOR BOLT STIFFENER CLAMP WHERE REQ'D V-A TYPE VAC SEISMIC RESTRAINT CABLE KIT V-A TYPE SRK/BB NOTE: AN ADDITIONAL CABLE KIT SHALL BE INSTALLED IN THE OPPOSING DIRECTION ON PIPE RUN TO BE EFFECTIVE PIPE PIPE CLAMP ISOMETRIC VIEW SEISMIC RESTRAINT CABLE KIT V-A TYPE SRK/BB PIPE SECURED TO SUPPORT ISOMETRIC VIEW SIDE VIEW HANGER ROD STIFFENER CLAMP WHERE REQ'D V-A TYPE VAC ANCHOR BOLT TO STRUCTURE PIPE SUPPORT (angle or strut channel) SEISMIC RESTRAINT CABLE KIT V-A TYPE SRK/BB NOTE: AN ADDITIONAL CABLE KIT SHALL BE INSTALLED IN THE OPPOSING DIRECTION ON PIPE RUN TO BE EFFECTIVE PIPE SIDE VIEW PIPE SECURED TO SUPPORT SUPPORT ISOMETRIC VIEW 45-60 ANCHOR BOLT TO STRUCTURE HANGER ROD STIFFENER CLAMP WHERE REQ'D V-A TYPE VAC Criteria: Seismic restraints shall be installed for all piping in accordance with the current edition of the International Building Code (IBC). Piping shall be restrained to resist horizontal seismic loads (Fp) in all directions and vertical seismic loads (Fpv). All seismic loads shall be transferred by the restraints from the piping to the building structure. Restraint sizes and their attachments shall be designed and installed to resist site specific seismic loads (Fp) as determined by the IBC. Restraint strengths shall be proven by calculation to withstand such loads. For all restraints, the maximum allowable load shall be based on the weakest component of the restraint with safety factors. Restraint calculations shall be stamped by a professional engineer licensed in the state in which the project is located. Transverse restraint spacing for ductile (e.g. steel) piping shall not exceed a maximum interval of 40 ft (2.2 m) on center. The distance between the last restraint and the end of the pipe shall not exceed 6 ft (.8 m). Transverse restraints shall be allowed to act as longitudinal restraints if they are within 24 in. (60 mm) of the centerline of the piping restrained longitudinally and the transverse restraint is on a pipe of equal or greater size than the pipe being restrained longitudinally. For non-ductile or brittle (e.g. cast iron) piping, all spacing criterion shall be divided by a minimum of two. 45-60 Max 4" Detail 2 - Longitudinal Cable Restraint 45-60 Max 4" Detail 3 - Combination Cable Restraint 45-60 45-60 Detail 4 - Transverse Cable Restraint (Trapeze) Detail 5 - Combination Cable Restraint (Trapeze) 45-60 45-60 Longitudinal restraint spacing for ductile (e.g. steel) piping shall not exceed a maximum interval of 80 ft (24.4 m) on center. The distance between the last restraint and the end of the pipe shall not exceed 40 ft (2.2 m). Longitudinal restraints shall be allowed to act as transverse restraints if they are within 24 in. (60 mm) of the centerline of the piping restrained transversely. For non-ductile or brittle (e.g. cast iron) piping, all spacing criterion shall be divided by a minimum of two. SIDE VIEW SIDE VIEW SIDE VIEW SIDE VIEW SIDE VIEW Rigid restraint systems shall only be used for piping that are not supported by vibration isolators and/or not thermally active. ANCHOR BOLT TO STRUCTURE -5/8" STRUT HANGER ROD STIFFENER CLAMP WHERE REQ'D V-A TYPE VAC HANGER ROD STIFFENER CLAMP WHERE REQ'D V-A TYPE VAC -5/8" STRUT ANCHOR BOLT TO STRUCTURE HANGER ROD ANCHOR BOLT TO STRUCTURE ATTACHMENT BRACKET V-A TYPE RRK STIFFENER CLAMP WHERE REQ'D V-A TYPE VAC ANCHOR BOLT TO STRUCTURE ANCHOR BOLT TO STRUCTURE ATTACHMENT BRACKET V-A TYPE RRK PIPE SECURED TO SUPPORT HANGER ROD STIFFENER CLAMP WHERE REQ'D V-A TYPE VAC ANCHOR BOLT TO STRUCTURE ATTACHMENT BRACKET V-A TYPE RRK PIPE SECURED TO SUPPORT HANGER ROD STIFFENER CLAMP WHERE REQ'D V-A TYPE VAC ATTACHMENT BRACKET V-A TYPE RRK CLEVIS HANGER ATTACHMENT BRACKET V-A TYPE RRK -5/8" STRUT CLEVIS HANGER ATTACHMENT BRACKET V-A TYPE RRK -5/8" STRUT -5/8" STRUT PIPE CLEVIS HANGER PIPE PIPE CLAMP PIPE PIPE CLAMP PIPE PIPE ISOMETRIC VIEW ISOMETRIC VIEW ISOMETRIC VIEW ISOMETRIC VIEW ISOMETRIC VIEW Detail 6 - Transverse Rigid Restraint Detail 7 - Longitudinal Rigid Restraint Detail 8 - Four-Way Rigid Restraint Detail 9 - Transverse Rigid Restraint (Trapeze) Detail 0 - Longitudinal Rigid Restraint (Trapeze) 45-60 45-60 45-60 45-60 SIDE VIEW SIDE VIEW ANCHOR BOLT TO STRUCTURE ANCHOR BOLT TO STRUCTURE -5/8" STRUT PIPE SECURED TO SUPPORT HANGER ROD STIFFENER CLAMP WHERE REQ'D V-A TYPE VAC -5/8" STRUT PIPE SECURED TO SUPPORT HANGER ROD STIFFENER CLAMP WHERE REQ'D V-A TYPE VAC LT XX NTS VISR-PS-0 Rev.2 ATTACHMENT BRACKET V-A TYPE RRK ATTACHMENT BRACKET V-A TYPE RRK SEISMIC BRACING DETAILS - PIPING - PIPE PIPE ISOMETRIC VIEW ISOMETRIC VIEW Detail - Transverse & Longitudinal Rigid Restraint (trapeze) Detail 2 - Transverse & Longitudinal Rigid Restraint (trapeze) (for reduced spaces) Detail 3 - Not Used Detail 4 - Not Used Detail 5 - Not Used

45-60 Detail - Transverse Cable Restraint (Option #) Detail 2 - Transverse Cable Restraint (Option #2) Detail 3 - Combination Cable Restraint (Option #) BY CHECK SCALE Seismic Restraints - Duct ANCHOR BOLT TO STRUCTURE HANGER ROD #0 SELF DRILLING SCREWS AT 6" O.C. STIFFENER CLAMP WHERE REQ'D V-A TYPE VAC HANGER ROD ANCHOR BOLT TO STRUCTURE STIFFENER CLAMP WHERE REQ'D V-A TYPE VAC ANCHOR BOLT TO STRUCTURE #0 SELF DRILLING SCREWS AT 6" O.C. HANGER ROD STIFFENER CLAMP WHERE REQ'D V-A TYPE VAC HANGER ROD #0 SELF DRILLING SCREWS AT 6" O.C. ANCHOR BOLT TO STRUCTURE STIFFENER CLAMP WHERE REQ'D V-A TYPE VAC HANGER ROD ANCHOR BOLT TO STRUCTURE STIFFENER CLAMP WHERE REQ'D V-A TYPE VAC Criteria: Seismic restraints shall be installed for all duct in accordance with the current edition of the International Building Code (IBC). Ductwork shall be restrained to resist horizontal seismic loads (Fp) in all directions and vertical seismic loads (Fpv). All seismic loads shall be transferred by the restraints from the ductwork to the building structure. SEISMIC RESTRAINT CABLE KIT V-A TYPE SRK/BB ALTERNATE CABLE ATTACHMENT LOCATION (NO TOP ANGLE BRACE REQUIRED) SEISMIC RESTRAINT CABLE KIT V-A TYPE SRK/BB #0 SELF DRILLING SCREWS AT 6" O.C. CABLE RESTRAINTS INSTALLED AT COMPOUND 45 ANGLE IN VERTICAL AND HORIZONTAL PLANES. SEISMIC RESTRAINT CABLE KIT V-A TYPE SRK/BB NOTE: AN ADDITIONAL CABLE KIT SHALL BE INSTALLED IN THE OPPOSING DIRECTION ON DUCT RUN TO BE EFFECTIVE ALTERNATE CABLE ATTACHMENT LOCATION (NO TOP ANGLE BRACE REQUIRED) CABLE RESTRAINTS INSTALLED AT COMPOUND 45 ANGLE IN VERTICAL AND HORIZONTAL PLANES. SEISMIC RESTRAINT CABLE KIT V-A TYPE SRK/BB NOTE: AN ADDITIONAL CABLE KIT SHALL BE INSTALLED IN THE OPPOSING DIRECTION ON DUCT RUN TO BE EFFECTIVE CABLE RESTRAINTS INSTALLED AT COMPOUND 45 ANGLE IN VERTICAL AND HORIZONTAL PLANES. SEISMIC RESTRAINT CABLE KIT V-A TYPE SRK/BB NOTE: AN ADDITIONAL CABLE KIT SHALL BE INSTALLED IN THE OPPOSING DIRECTION ON DUCT RUN TO BE EFFECTIVE #0 SELF DRILLING SCREWS AT 6" O.C. Restraint sizes and their attachments shall be designed and installed to resist site specific seismic loads (Fp) as determined by the IBC. Restraint strengths shall be proven by calculation to withstand such loads. For all restraints, the maximum allowable load shall be based on the weakest component of the restraint with safety factors. Restraint calculations shall be stamped by a professional engineer licensed in the state in which the project is located. Transverse restraint spacing for duct shall not exceed a maximum interval of 30 ft on center. Longitudinal restraint spacing for duct shall not exceed a maximum interval of 60 ft on center. Detail 4 - Combination Cable Restraint (Option #2) Detail 5 - Combination Cable Restraint (Round) Detail 6 - Not Used Detail 7 - Not Used Detail 8 - Not Used Detail 9 - Not Used Detail 0 - Not Used LT 8/4/202 XX NTS VISR-DS-0 SEISMIC BRACING DETAILS - DUCT- Detail - Not Used Detail 2 - Not Used Detail 3 - Not Used Detail 4 - Not Used Detail 5 - Not Used

VIBRATION ISOLATION & SEISMIC/WIND RESTRAINT SUBMITTAL Project: Date: Project No.: Disclaimers, Assumptions and Directive Statements:. Seismic and/or wind calculations will be provided for non structural components as per Vibro Acoustics scope of work and provided in accordance with the specified edition of applicable building codes (e.g., International Building Code with local amendments). In cases where the required seismic and wind factors are not provided, the currently adopted code used in the region will be used and factors will be assumed as applicable to the region. 2. Equipment weights and dimensions used in Vibro Acoustics work will be taken from approved submittals provided by the contractor to Vibro Acoustics. The contractor shall communicate any deviations or changes to Vibro Acoustics for review; significant changes to equipment after time of release may result in additional fees. 3. All restraint attachments to building structure will be defined by Vibro Acoustics. Where information is not provided to Vibro Acoustics as to the type of building material at the point of attachment, Vibro Acoustics will make a reasonable assumption. Additional work to change from these assumptions due to lack of provided information at time of release may be considered additional scope of services and may result in additional fees. It is the responsibility of the contractor to communicate seismic loads determined by Vibro Acoustics to the project s structural engineer of record. 4. Unless included in Vibro Acoustics scope of work, housekeeping pads will be assumed to be adequately dowelled to the supporting structure and reinforced to withstand seismic loads. 5. Unless included in Vibro Acoustics scope of work, all suspended equipment and all floor mounted equipment installed on vibration isolators will be assumed to be flexibly connected to associated conduit, piping and/or ductwork to prevent failure or damage from seismic loads on the equipment. 6. The contractor shall install all concrete anchor bolts to the manufacturers recommended torque. Vibro Acoustics will assume that the concrete depth and edge distances shall be sufficient for proper installation as noted in the appropriate calculations. The contractor must review the work and if anchorage requirements cannot be satisfied, the contractor shall inform Vibro Acoustics for review and rework as appropriate. The installing contractor shall comply with all special inspection requirements. 7. All equipment and components supplied by others, including ductwork or piping, concrete housekeeping pads, customized support structures and building structure components are not certified by Vibro Acoustics analyses as capable to withstand the applied seismic loads. Mounting supports, brackets, or other means of attachment not provided by Vibro Acoustics must be certified by others. Unless otherwise noted, calculations provided by Vibro Acoustics apply only to components provided by Vibro Acoustics such as seismic spring isolators, brackets and restraints and their attachments to structure. 8. Vibro Acoustics assumes the following as part of standard building design criteria: Steel structure provided by others between the equipment and isolators is determined by others and is considered sufficiently rigid to transfer seismic loads. The building support structure will have at least ten times the stiffness of the specified isolators. The building support structure natural frequency will be at least three times the natural frequency of the specified isolators. 9. Vibro Acoustics will consider worst case loading scenarios for seismic/wind calculations for groups of identical or similar pieces of equipment. 0. All drawings included in Vibro Acoustics submittals are not to scale unless otherwise noted.