DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: COATED FOAM ROOFING REPORT HOLDER: COVESTRO, LLC

Similar documents
DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: COATED FOAM ROOFING REPORT HOLDER: NCFI POLYURETHANES

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: COATED FOAM ROOFING REPORT HOLDER: LAPOLLA INDUSTRIES, INC.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: COATED FOAM ROOFING REPORT HOLDER: BASF CORPORATION

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: CHEMICAL BROTHERS INTERNATIONAL, LLC

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION SECTION: AIR BARRIERS REPORT HOLDER:

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: MODIFIED BITUMINOUS SHEET ROOFING REPORT HOLDER:

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: DEMILEC (USA) INC.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: DEMILEC (USA) INC.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: DEMILEC (USA) INC.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: BASF CORPORATION (RIGID PU SYSTEMS)

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: DEMILEC (USA) INC.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: DEMILEC (USA) INC.

DIVISION: THERMAL AND MOISTURE SECTION: THERMAL INSULATION REPORT HOLDER: CERTAINTEED CORPORATION

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: DEMILEC (USA) LLC

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: CERTAINTEED CORPORATION

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: NATURAL POLYMERS, LLC

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: FIRESTOPPING REPORT HOLDER: PASSIVE FIRE PROTECTION PARTNERS

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: THE SPRAY MARKET, INC.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: RHINO LININGS CORPORATION

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: ROOFING AND SIDING PANELS REPORT HOLDER: KINGSPAN INSULATED PANELS, INC.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: DEMILEC (USA) INC.

REPORT HOLDER: R.L. ADAMS PLASTICS, INC CROSSROADS COMMERCE PARKWAY WYOMING, MICHIGAN EVALUATION SUBJECT: POLYCORE BRAND INSULATION

LEGACY REPORT DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: FLUID APPLIED ROOFING REPORT HOLDER: METACRYLICS

ESR-2072 Reissued September 1, 2013 This report is subject to renewal September 1, 2015.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION SECTION: WATER RESISTIVE BARRIERS/WEATHER BARRIERS

DIVISION: FINISHES SECTION: FIRE RETARDANT COATINGS REPORT HOLDER: FIRE RETARDANT COATINGS OF TEXAS, LLC

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION SECTION: WATER-RESISTIVE BARRIERS/WEATHER BARRIERS

REPORT HOLDER: CARLISLE SYNTEC POST OFFICE BOX 7000 CARLISLE, PENNSYLVANIA EVALUATION SUBJECT:

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: WATER RESISTIVE BARRIERS/WEATHER BARRIERS REPORT HOLDER: PAREX USA, INC.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION SECTION: WATER-RESISTIVE BARRIERS/WEATHER BARRIERS

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: CLAY ROOF TILES REPORT HOLDER: BORAL ROOFING LLC

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: REFLECTIX INCORPORATED

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: METAL ROOF PANELS SECTION: METAL WALL PANELS REPORT HOLDER:

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: POLYVINYL CHLORIDE ROOFING REPORT HOLDER: IB ROOF SYSTEMS

LEGACY REPORT DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: FLUID APPLIED ROOFING REPORT HOLDER: CONKLIN COMPANY INC.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: CLAY ROOF TILES REPORT HOLDER: CERAMICA LA ESCANDELLA, S.A.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: PEDESTRIAN TRAFFIC COATINGS REPORT HOLDER: WESTCOAT

REPORT HOLDER: COREV AMERICA BRITTMOORE PARK DRIVE HOUSTON, TEXAS EVALUATION SUBJECT:

REPORT HOLDER: RARE MANUFACTURING INC A AVENUE SURREY, BRITISH COLUMBIA V4N 4P2 CANADA EVALUATION SUBJECT: IRONWOOD SHAKE

REPORT HOLDER: LOUISIANA-PACIFIC CORPORATION 414 UNION STREET, SUITE 2000 NASHVILLE, TENNESSEE EVALUATION SUBJECT:

DIVISION: CONCRETE SECTION: SPECIALTY PLACED CONCRETE REPORT HOLDER: EMMEDUE S.P.A.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: METAL ROOF PANELS SECTION: ROOF PANELS REPORT HOLDER: ROSER CO., LTD.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: APPLIED FIREPROOFING REPORT HOLDER: CARBOLINE COMPANY

ESR-1655 Reissued April 2014 This report is subject to renewal April 1, 2016.

REPORT HOLDER: AEROSMITH FASTENING SYSTEMS 5621 DIVIDEND ROAD INDIANAPOLIS, INDIANA EVALUATION SUBJECT: AEROSMITH 5000 SERIES FASTENERS

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: COMPOSITE RUBBER SHAKES REPORT HOLDER: DAVINCI ROOFSCAPES, LLC

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: METAL ROOF PANELS SECTION: METAL WALL PANELS REPORT HOLDER:

REPORT HOLDER: AEROSMITH FASTENING SYSTEMS 5621 DIVIDEND ROAD INDIANAPOLIS, INDIANA EVALUATION SUBJECT: AEROSMITH 3000 SERIES FASTENERS

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: PEDESTRIAN TRAFFIC COATINGS REPORT HOLDER: PLI DEK LLC

Trusted DIVISION: 07 SYSTEM. Conformity! ICC-ES Evaluation. not specifically. Copyright 2014

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: METAL WALL PANELS REPORT HOLDER: FCP, INC.

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: STRUCTURAL PANELS REPORT HOLDER: FOUR SEASONS SOLAR PRODUCTS

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: METAL ROOF PANELS REPORT HOLDER: METAL SALES MANUFACTURING CORPORATION

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: METAL WALL PANELS REPORT HOLDER: METL SPAN, A DIVISION OF NCI GROUP, INC.

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: STRUCTURAL PANELS REPORT HOLDER: ENERCEPT, INC.

REPORT HOLDER: FEROOF CO., LTD SEONWON LI SEONNAM MYEON SUNGJU GUN KYEONGSANGBUK DO SOUTH KOREA EVALUATION SUBJECT:

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: PLASTIC SIDING REPORT HOLDER: KP BUILDING PRODUCTS

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: COMPOSITE WALL PANELS REPORT HOLDER:

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: COMPOSITE WALL PANELS REPORT HOLDER: ARCONIC ARCHITECTURAL PRODUCTS, LLC

REPORT HOLDER: INSULFOAM, A DIVISION OF CARLISLE CONSTRUCTION MATERIALS, INC TH AVENUE EAST PUYALLUP, WASHINGTON EVALUATION SUBJECT:

DIVISION: METALS SECTION: STEEL DECKING REPORT HOLDER: EPIC METALS CORPORATION 11 TALBOT AVENUE RANKIN, PENNSYLVANIA 15104

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: NAILS REPORT HOLDER: BOSTITCH FASTENING SYSTEMS

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: COMPOSITE WALL PANELS REPORT HOLDER: FUNDERMAX GMBH

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: PLASTIC SIDING REPORT HOLDER: GENTEK BUILDING PRODUCTS, INC.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: FIBER CEMENT SIDING REPORT HOLDER: RIEDER FASERBETON ELEMENTE GmbH

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: ETHYLENE PROPYLENE DIENE MONOMER ROOFING REPORT HOLDER:

DIVISION: METALS SECTION: METAL FABRICATIONS REPORT HOLDER: QUALITY WAY PRODUCTS, LLC 407 HADLEY STREET HOLLY, MICHIGAN 48442

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: STRUCTURAL PLASTICS SECTION: PLASTIC DECKING REPORT HOLDER:

REPORT HOLDER: JAACO CORPORATION NE 68 TH STREET, SUITE C 130 REDMOND, WASHINGTON EVALUATION SUBJECT:

DIVISION: FINISHES SECTION: SUSPENSION SYSTEMS REPORT HOLDER: WORTHINGTON ARMSTRONG VENTURE (WAVE)

DIVISION: METALS SECTION: STEEL DECKING SECTION: STEEL FLOOR DECKING SECTION: STEEL ROOF DECKING REPORT HOLDER:

REPORT HOLDER: GREENMAKER INDUSTRIES, LLC 697 OAKWOOD AVENUE WEST HARTFORD, CONNECTICUT EVALUATION SUBJECT: DECOPLAST DDARS NOTCHED

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: COMPOSITE WALL PANELS REPORT HOLDER: PARKLEX USA

REPORT HOLDER: OMEGA PRODUCTS INTERNATIONAL, INC CALIFORNIA AVENUE CORONA, CALIFORNIA EVALUATION SUBJECT:

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: METAL WALL PANELS DIVISION: SIDING REPORT HOLDER: VM ZINC

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: SES FOAM

DIVISION: FINISHES SECTION: PORTLAND CEMENT PLASTERING REPORT HOLDER: PROWALL BUILDING PRODUCTS, INC.

REPORT HOLDER: PAREX USA, INC EAST LA PALMA AVENUE, SUITE 250 ANAHEIM, CALIFORNIA EVALUATION SUBJECT:

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: PEDESTRIAN TRAFFIC COATINGS REPORT HOLDER: HILL BROTHERS CHEMICAL COMPANY

DIVISION: FINISHES SECTION: GYPSUM BOARD REPORT HOLDER: PANEL REY, S.A.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: PLASTIC SIDING REPORT HOLDER: KAYCAN LTD.

REPORT HOLDER: ispan SYSTEMS LP 70 BRENTWOOD DRIVE PRINCETON, ONTARIO N0J 1V0 CANADA EVALUATION SUBJECT:

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: LAPOLLA INDUSTRIES, INC.

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: FIRE RETARDANT WOOD TREATMENT REPORT HOLDER: VIANCE, LLC

ESR-1365 Reissued March 2014 This report is subject to renewal April 1, 2015.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: PLASTIC SIDING REPORT HOLDER: DERBY BUILDING PRODUCTS INCORPORATED

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: PLASTIC SIDING REPORT HOLDER: ASSOCIATED MATERIALS, INC.

REPORT HOLDER: CALIFORNIA EXPANDED METAL PRODUCTS COMPANY (CEMCO) CROSSROADS PARKWAY NORTH, SUITE 325 CITY OF INDUSTRY, CALIFORNIA 91746

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: COMPOSITE WALL PANELS REPORT HOLDER:

DIVISION: MASONRY SECTION: MASONRY ANCHORS REPORT HOLDER: POWERS FASTENERS, INC. 701 EAST JOPPA ROAD TOWSON, MARYLAND 21286

REPORT HOLDER: BLUE POINT FASTENING, INC YORBA COURT CHINO, CALIFORNIA EVALUATION SUBJECT:

REPORT HOLDER: HILTI, INC DALLAS PARKWAY, SUITE 1000 PLANO, TEXAS EVALUATION SUBJECT:

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: COMPOSITE WALL PANELS REPORT HOLDER: 3A COMPOSITES USA INC.

REPORT HOLDER: THE DOW CHEMICAL COMPANY 1501 LARKIN CENTER DRIVE MIDLAND, MICHIGAN EVALUATION SUBJECT:

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: STRUCTURAL PLASTICS SECTION: PLASTIC DECKING REPORT HOLDER:

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: METAL SHINGLES REPORT HOLDER: TEFUTE BUILDING MATERIALS COMPANY, LLC

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: WATER RESISTIVE BARRIERS/WEATHER BARRIERS SECTION: AIR BARRIERS

REPORT HOLDER: GEORGIA PACIFIC GYPSUM LLC 2861 MILLER ROAD DECATUR, GEORGIA EVALUATION SUBJECT: DENSELEMENT BARRIER SYSTEM

REPORT HOLDER: HILTI, INC DALLAS PARKWAY, SUITE 1000 PLANO, TEXAS EVALUATION SUBJECT: HILTI LOW-VELOCITY POWER-ACTUATED FASTENERS

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: ICYNENE, INC.

Transcription:

0 Most Widely Accepted and Trusted ICC-ES Evaluation Report ICC-ES 000 (800) 423-6587 (562) 699-0543 www.icc-es.org ESR-1221 Reissued 12/2017 This report is subject to renewal 12/2018. DIVISION: 07 00 00 THERMAL AND MOISTURE PROTECTION SECTION: 07 57 00 COATED FOAM ROOFING REPORT HOLDER: COVESTRO, LLC 2400 SPRING STUEBNER ROAD SPRING, TEXAS 77389 EVALUATION SUBJECT: BAYSEAL SPRAY-APPLIED POLYURETHANE ROOFING SYSTEMS Look for the trusted marks of Conformity! 2014 Recipient of Prestigious Western States Seismic Policy Council (WSSPC) Award in Excellence A Subsidiary of ICC-ES Evaluation Reports are not to be construed as representing aesthetics or any other attributes not specifically addressed, nor are they to be construed as an endorsement of the subject of the report or a recommendation for its use. There is no warranty by ICC Evaluation Service, LLC, express or implied, as to any finding or other matter in this report, or as to any product covered by the report. Copyright 2018 ICC Evaluation Service, LLC. All rights reserved.

ICC-ES Evaluation Report www.icc-es.org (800) 423-6587 (562) 699-0543 ESR-1221 Reissued December 2017 Revised January 2018 This report is subject to renewal December 2018. A Subsidiary of the International Code Council DIVISION: 07 00 00 THERMAL AND MOISTURE PROTECTION Section: 07 57 00 Coated Foam Roofing REPORT HOLDER: COVESTRO, LLC 2400 SPRING STUEBNER ROAD SPRING, TEXAS 77389 (281) 350-9000 www.polyurethanes.covestro.com EVALUATION SUBJECT: BAYSEAL SPRAY-APPLIED POLYURETHANE ROOFING SYSTEMS ADDITIONAL LISTEE: MOMENTIVE PERFORMANCE MATERIALS 260 HUDSON RIVER ROAD WATERFORD, NEW YORK 12188 PRODUCT NAME: SERIES SILICONE ROOF COATING (SERIES 3402, 3404, 3405 AND 3408) 1.0 EVALUATION SCOPE Compliance with the following codes: 2009 International Building Code (IBC) 2013 Abu Dhabi International Building Code (ADIBC) The ADIBC is based on the 2009 IBC. 2009 IBC code sections referenced in this report are the same sections in the ADIBC. Other Codes (see Section 8.0) Properties evaluated: Physical properties Impact resistance Wind resistance Fire classification Elimination of thermal barrier (roofing) 2.0 USES The spray-applied polyurethane roofing systems described in this evaluation report are used in the construction of classified roof coverings as noted in Table 1. The roof covering systems recognized in this report may be used on buildings of any type of construction. 3.0 DESCRIPTION 3.1 General: spray-applied polyurethane roofing systems consist of 2.5/3.0 series spray-applied polyurethane foam insulation covered with Bayblock II, Bayblock HT or series liquid-applied coatings. When installed as described in this report, these systems have roof classifications as set forth in Table 1. 3.2 Spray Polyurethane Foam Plastic Insulation: 3.2.1 General: 2.5/3.0 series spray-applied polyurethane foam complying with ASTM C1029 Type III, has a nominal density between 2.5 pcf (40 kg/m 3 ) and 3.0 pcf (48 kg/m 3 ). The foam plastic liquid components (designated component A and component B) are available in 55-gallon (208 L) containers and have a six-month shelf life when stored out of direct sunlight at temperatures between 50ºF and 80ºF (10 C and 27 C). 3.2.2 Surface-burning Characteristics: 2.5/3.0 series spray-applied polyurethane foam plastic has a flame-spread index of 75 or less and a smoke-developed index of greater than 450 when tested in accordance with UL 723 at a maximum thickness of 2.5 inches (63.5 mm). The classified roof assemblies noted in Table 1, containing foam plastic insulation, are recognized for use without a thermal barrier based on testing in accordance with UL 1256, as specified in IBC Section 2603.4.1.5. 3.3 Coatings: 3.3.1 Bayblock II Acrylic Roof Coating: Bayblock II acrylic roof coating is a single-component, liquid-applied, 100 percent acrylic elastomeric coating complying with ASTM D6083, produced by Covestro, LLC. It is available in 5-gallon (19 L), 55-gallon (208 L) and 275-gallon (1045 L) containers with a shelf life of twelve months when stored in factory-sealed containers at temperatures between 50 F and 100 F (10 C and 38 C). 3.3.2 Bayblock HT Acrylic Roof Coating: Bayblock HT acrylic roof coating is a single-component, liquidapplied, 100 percent acrylic elastomeric coating complying with ASTM D6083, produced by Covestro, LLC. It is available in 5-gallon (19 L), 55-gallon (208 L) and 275-gallon (1045 L) containers with a shelf life of twelve months when stored in factory-sealed containers at temperatures between 50 F and 100 F (10 C and 38 C). 3.3.3 Silicone Roof Coating: SCM 3400 series silicone roof coating is a single-component, silicone rubber liquid coating complying with ASTM D6694, produced by Momentive Performance Materials. It is available in 6-gallon pails (22.7 L) and 55-gallon (208 L) drums and has a shelf life of eighteen months when stored in factory-sealed containers at temperatures between 50 F and 100 F (10 C and 38 C). ICC-ES Evaluation Reports are not to be construed as representing aesthetics or any other attributes not specifically addressed, nor are they to be construed as an endorsement of the subject of the report or a recommendation for its use. There is no warranty by ICC Evaluation Service, LLC, express or implied, as to any finding or other matter in this report, or as to any product covered by the report. Copyright 2018 ICC Evaluation Service, LLC. All rights reserved. Page 1 of 4

ESR-1221 Most Widely Accepted and Trusted Page 2 of 4 3.4 Wind Resistance: The allowable wind uplift pressures for the coated 2.5/3.0 spray polyurethane foam insulation roof covering assemblies are set forth in Table 2 of this evaluation report. 3.5 Impact and Foot Traffic Resistance: The foam insulation roof coverings described in this evaluation report comply with the resistance to foot traffic requirements in Section 5.5 of FM 4470. 4.0 INSTALLATION 4.1 Preparation of Substrate: The substrates to be covered must be free of grease, oil, loose particles, moisture and other foreign materials. Areas not receiving a polyurethane foam plastic application must be masked off or otherwise protected from overspray, and openings in the roof covering system must be flashed in accordance with IBC Section 1503.2, and installed in accordance with the manufacturer s published installation instructions. 4.2 Substrates: 4.2.1 Combustible Substrates: Combustible substrates must be minimum 15 / 32-inch-thick (11.9 mm), codecomplying, exterior grade or Exposure 1 plywood. All plywood substrate edges must be supported by blocking or have tongue-and-groove joints as required by IBC Section 2603.4.1.5. The wood surface must be primed with a suitable primer/sealer when specifically required by the manufacturer s installation instructions. 4.2.2 Substrates: 4.2.2.1 Cementitious Substrates: Structural concrete must have a minimum compressive strength of 2500 psi (17.2 MPa). Cementitious decks must be thoroughly cured and must be subjected to specialized treatment, such as wire brushing or commercial sand blasting, or must be chemically cleaned to ensure adequate bonding when specifically required by manufacturers installation instructions. Application of suitable primer may be required before application of spray foam plastic insulation, in accordance with the manufacturer s installation instructions. 4.2.2.2 Metal Substrates: Metal decks must be minimum No. 22 gage [0.03 inch (0.76 mm)] steel. Metal decks must be cleaned of any adhesion inhibitors. If free of rust or loose scale, the steel surface may be cleaned by use of air jet, vacuum equipment, or hand or power broom to remove loose dirt. Grease, oil or other obvious contaminants must be removed by a suitable detergent or cleaner. Application of a suitable primer may be required before application of the spray foam plastic, in accordance with manufacturer s installation instructions. 4.3 Roof Slope: The polyurethane foam plastic insulation must be sprayapplied to form roof slopes that have a minimum slope of 1 / 4:12 (2 percent) and a maximum roof slope as specified in Table 1. 4.4 Foam Plastic Insulation Application: 2.5/3.0 spray polyurethane foam plastic insulation is spray-applied to the prepared substrate in minimum 1 / 2-inch- to 1-inch-thick (12.7 mm to 25.4 mm) passes to the thickness specified in Table 1, allowing a minimum of three minutes of curing time between passes. The insulation components are dispensed at a 1:1 ratio at the temperature and pressure specified in the manufacturer s installation instructions. Application of the foam plastic insulation must be performed when the substrate surface temperature is at least 50 F (10 C), the ambient temperature is at least 50 F (10 C) and the wind speed is no more than 15 miles per hour (6.7 m/s). The foam plastic must not be applied when the humidity is greater than 85 percent, when the dew point and the ambient temperature are within 5 F of one another, or when wind speeds are greater than 15 miles per hour (6.7 m/s). Adequate wind barriers are needed when wind speed is greater than 15 miles per hour (6.7 m/s). The foam plastic must not be applied to wet or damp substrates, or when dew, condensation, precipitation, or freezing temperatures are expected prior to completion of the foam and coating application. The finished foam surface must be smooth and free of voids, pinholes and crevices. At least a two-hour curing period is required prior to application of the coating. 4.5 Application of Coating: The foam plastic insulation must be dry and free of all damaged foam, dirt and foreign material before application of the coating. The coating must be applied in accordance with the coating manufacturer s application instructions, no less than two hours nor more than 72 hours following application of the foam plastic insulation. The coating may be applied with brush or roller or by using spray equipment capable of handling high-viscosity liquids at the specified rates found in Table 1. The first coating must cure before application of the second coat. The ambient temperature must be greater than 50 F (10 C) during application and above 32 F (0 C) for at least a 24-hour period after application. 4.6 Fire Classification: 4.6.1 New Construction: Roof covering systems, as noted in Table 1, when installed in accordance with this evaluation report, are Class A roof coverings in accordance with UL 790 (ASTM E108). 4.6.2 Reroofing: Prior to installation of the new roof covering system, inspection in accordance with IBC Section 1510 and approval from the code official having jurisdiction are required. This report recognizes recovering over uninsulated existing systems only, and recovering must be in accordance with IBC Section 1510. 5.0 CONDITIONS OF USE The spray-applied polyurethane roofing systems described in this report comply with, or are suitable alternatives to what is specified in, those codes listed in Section 1.0 of this report, subject to the following conditions: 5.1 The installation and application of the coated foam plastic roof covering systems must comply with the code, the report holder s published application instructions and this evaluation report. If there are any conflicts between the report holder s application instructions and this evaluation report, this report governs. 5.2 All materials must be applied by installers approved by Covestro, LLC. 5.3 Where moderate or heavy foot traffic occurs, such as for maintenance of equipment, the roof covering must be adequately protected to prevent rupture or wearing of the surface.

ESR-1221 Most Widely Accepted and Trusted Page 3 of 4 5.4 The allowable wind uplift pressures listed in Table 2 are for the roof covering only. The deck and supporting structure to which the roof covering is attached must be designed to withstand the applicable wind pressure determined in accordance with ASCE 7 or Section 1609.6 of the IBC. 5.5 Flashing when required must be installed in accordance with IBC Section 1503.2. 5.6 The 2.5/3.0 polyurethane foam plastic insulation and the Bayblock II and HT liquid-applied coatings are manufactured in Spring, Texas, and Phoenix, Arizona, under a quality control program with inspections by ICC-ES. The series liquid-applied coating is manufactured by Momentive Performance Materials in Waterford, New York, under a quality control program with inspections by ICC-ES. 6.0 EVIDENCE SUBMITTED 6.1 Data in accordance with the ICC-ES Acceptance Criteria for Spray-applied Foam Plastic Insulation (AC377), dated April 2016. 6.2 Reports of tests in accordance with ASTM D6083 and ASTM D6694. 6.3 Reports of tests in accordance with FM 4470 and FM 4474. 6.4 Reports of tests in accordance with UL 723 (ASTM E84). 6.5 Reports of tests in accordance with UL 790 (ASTM E108). 6.6 Reports of tests in accordance with UL 1256. 7.0 IDENTIFICATION Each container of 2.5/3.0 spray-applied polyurethane foam insulation bears a label with the Covestro name and address, the product name ( 2.5, 2.7 or 3.0), the component type (A or B), the lot numbers, the flame spread index, the date of manufacture, and the evaluation report number (ESR-1221). Each container of Bayblock liquid-applied coatings bears a label with the Covestro name and address, the product name (Bayblock II or Bayblock HT), the lot number, and the evaluation report number (ESR-1221). Each container of series silicone roof coating bears a label with the manufacturer s name (Momentive Performance Materials) and address, the product name ( ), the shelf life and the date of manufacture, and the evaluation report number (ESR-1221). 8.0 OTHER CODES In addition to the code referenced in Section 1.0, the roofing systems recognized in this report have also been evaluated for compliance with the requirements of the 2006 International Building Code (2006 IBC). The products comply with the 2006 IBC as described in Section 2.0 through 7.0 of the report, except wind uplift resistance under the 2006 IBC is in accordance with FM 4470.

ESR-1221 Most Widely Accepted and Trusted Page 4 of 4 SYSTEM NO. 1 1 2 3 4 5 ROOF DECK TYPE 2 15 / 32-inchthick combustible substrate TABLE 1 BAYSEAL 2.5/3.0 ROOF COVERING SYSTEMS FIRE CLASSIFICATION FOAM PLASTIC COATING TOP INSULATION 3 SURFACING Product Designation Thickness (inches) TYPE Bayblock II Bayblock HT Application Rate MAXIMUM ROOF SLOPE (in/ft) ROOF CLASSIFICATION 3:12 A 2:12 A 1:12 A Unlimited A For SI: 1 inch = 25.4 mm; 1 gallon per 100 ft 2 = 0.41 L/m 2 ; 1 gallon = 3.785 L; 1 ft 2 = 0.0929 m 2 ; 1 lb/100ft 2 = 0.0489 kg/m 2. 1 / 2:12 B 1 Roof covering systems No. 1 5 may be applied over an existing uninsulated roof covering without changing the existing roof covering fire classification. 2 When roof covering systems No. 1 4 are installed over a combustible deck (minimum 15 / 32 inch), a 1 / 4-inch-thick (6.4 mm) G-P Gypsum DensDeck roof board or DensDeck Prime roof board must be mechanically fastened over the combustible deck. The joints in the G-P gypsum board must be offset a minimum of 6 inches (152 mm) from the joints in the combustible deck. 3 The foam plastic insulation must be UL-classified. TABLE 2 WIND RESISTANCE OF COATED ROOF COVERINGS 1,4 SYSTEM NO. SUBSTRATE ALLOWABLE WIND UPLIFT (psf) FOAM THICKNESS (inches) W1 Structural concrete 990 2 W2 Steel deck 2,3 210 2 W3 Steel deck 2,3 150 2 W4 Steel deck 2,3 90 2 W5 For SI: 1 inch = 25.4 mm; 1psf = 0.0479 kpa. 15 / 32 combustible 160 1 1 Foam plastic insulations and coatings must be applied in accordance with the manufacturer s installation instructions and this report. Concrete substrate and steel deck substrate must be the same as recognized in this evaluation report and listed by FM. 2 Painted or galvanized steel deck secured to minimum 1 / 4-inch-thick (6 mm) steel supports, a maximum of 6 feet (1.8 m) on center, with ITW Buildex Teks 4 or Teks 5 fasteners at 6 inches (152 mm) on center (every rib). Side laps are secured with ITW Buildex Teks 1 fasteners a maximum of 30 inches (762 mm) on center. Deck is washed with a trisodium phosphate (TSP) and water solution, rinsed and allowed to dry. 3 Painted galvanized steel deck secured to minimum 1 / 4-inch-thick (6 mm) steel supports, a maximum of 6 feet (1.8 m) on center, with ITW Buildex Traxx/4 or 5 fasteners a maximum of 6 inches (152 mm) on center (every rib). Side laps are secured with ITW Buildex Stitch Traxx/1 fasteners a maximum of 30 inches (762 mm) on center. Deck is washed with a trisodium phosphate (TSP) and water solution, rinsed and allowed to dry. 4 Assembly must be FM-approved.