[PPT PDF] Pharmaceutical Water System Design Validation - Microbial Testing of Water is discussed in detail in this article.

Similar documents
Lab 2-Microbial Enumeration

Chapter 6: Microbial Growth

á61ñ MICROBIOLOGICAL EXAMINATION OF NONSTERILE PRODUCTS: MICROBIAL ENUMERATION TESTS

USP <1116> and Contamination

Overview of a sterility assurance program for PET drugs

Microbiological Quality: Understanding Drinking Water Quality and Management

Media Fill A Process Simution. Presented By Shikha Chauhan

Solutions for All Your Aseptic Parenteral Drug Formulation/Filling Needs. BUBBLE-FREE FILLING : A New Option in Prefilled Syringe Filling

á62ñ MICROBIOLOGICAL EXAMINATION OF NONSTERILE PRODUCTS: TESTS FOR SPECIFIED MICROORGANISMS

MICROBIOLOGICAL TOOLS FOR QUALITY ASSURANCE IN HATCHERY: Laboratory Methods

Review Validation of aseptic processes for pharmaceuticals

The Parenteral Drug Association

The Most Probable Number Method and Its Use in QC Microbiology

IDEXX Summary. IDEXX Laboratories. Date: April Report Highlights:

Tests to Support Sterility Claim. Imtiaz Ahmed

Final text for addition to The International Pharmacopoeia

Effect of holding time on E.coli Densities in Wastewater Samples

Microbial Growth. Phases of Growth. Pariporina: Bakteerien kasvukäyrä kuvaajana - Piirrä bakteerien klassinen kasvukäyrä - Nimeä kasvun eri vaiheet

TESTING SERVICES by Analyte

Microbiological tests not just for safe drinking water. PRACTICE REPORT MICROBIOLOGY Author: Dr. Elmar Grabert, HACH LANGE GmbH, Germany

Test Method for Efficacy of Copper Alloy Surfaces as a Sanitizer

Bacterial Counts - Quantitative Analysis of Microbes

Efficacy Report Summarization for SoClean 2

MICROBIAL GROWTH. Dr. Hala Al-Daghistani

Modified mtec Agar, Colilert, and M-FC Agar - Field Trial Comparison of Bacteria Enumeration Methods in Surface Waters of Eastern Wyoming

Microbial Growth. PowerPoint Lecture Presentations prepared by Bradley W. Christian, McLennan Community College C H A P T E R

Aseptic Process Validation

characterized and identified as part of a study of heterotrophic

ISO INTERNATIONAL STANDARD. Cleanrooms and associated controlled environments Biocontamination control Part 1: General principles and methods

TRYPTIC SOY AGAR (TSA) WITH LECITHIN AND TWEEN 80

UNDER SECRETARY FOR HEALTH S INFORMATION LETTER MICROBIOLOGICAL ASSESSMENT OF PHARMACEUTICAL CLEANROOMS

Environmental Monitoring of Aseptic Processing Areas - 1

EZ-Fluo System. For rapid detection of spoilage organisms in wine

Annex A2. Guidance on Process Validation Scheme for Aseptically Processed Products

2.4 TYPES OF MICROBIAL CULTURE

Microbiological Cleaning Method Validation

Final text for addition to The International Pharmacopoeia

MODULE 2D ENVIRONMENTAL MICROBIOLOGICAL LABORATORY ACCREDITATION PROGRAM (EMLAP) ADDITIONAL REQUIREMENTS

Microbial Growth. PowerPoint Lecture Presentations prepared by Bradley W. Christian, McLennan Community College C H A P T E R

VALIDATION GUIDE - ASTM F Challis Ag+ Tap MicroFilter - Terminal disposable microfilter for Tap with incorporated anti-bacterial filter

A24 CALA Checklist for Microbiology Revision 4.1 February 16, 2018

USP Chapter 823 USP 32 (old) vs. USP 35 (new)

ALTERNATIVE METHODS FOR CONTROL OF MICROBIOLOGICAL QUALITY

Bioburden Contamination Control: A Holistic Overview

2018 North America Lab Services Fee Schedule

Handbook of Microbiological Quality Control

A Comparison of the Bacteriological Quality of Drinking Water for the City of Johannesburg in the Wet and Dry Season

MicroFunnel Filter Funnels

INTRODUCTION Sanitization sterilization Antibiotics Bactericidal Bacteriostatic Antiseptics disinfectants

The Most Probable Number Method and Its Use in QC Microbiology

2. 47 mm grid marked, white sterile 0.45 micron membranes (Millipore or equivalent) 4. Vacuum pump capable of inches of vacuum

ASSESSMENT OF THE MICROBICIDAL ACTIVITY OF AN ACCELERATED HYDROGEN PEROXIDE- BASED FORMULATION (AHP-5) AGAINST VRE AND MRSA

Creating a Culture of Data Integrity Using an Automated Detection and Enumeration Method

J. Serb. Chem. Soc. 79 (12) S186 S190 (2014) Supplementary material

Laboratory Procedure October 1999 HEALTH PROTECTION BRANCH OTTAWA ANALYSIS OF SPROUTS FOR COLIFORMS, ESCHERICHIA COLI, AND KLEBSIELLA PNEUMONIAE..

Outline. Sampling purpose D-2 standard Ballast water biology Indicative vs detailed analysis Organisms detection methods Viability Minimum dimension

TECHNICAL NOTENo. 6 DECEMBER Authors: - Olivier MOLINIER - Mylène MARECHAL

Environmental Biotechnology. CE421/521 Tim Ellis October 25, 2007

EZ-Fit Filtration Units Ready-to-use sterilized filtration devices for microbial enumeration

V1. VALIDATION GUIDE - ASTM F SAFETap of POLYMEM - Terminal disposable microfilter for Tap with incorporated anti-bacterial filter

Cell Growth and DNA Extraction- Technion igem HS

Microbiological Consideration for Non-Sterile Pharmaceutical

REQUIREMENTS FOR MEMBRANE FILTERS FOR MICROBIOLOGICAL CULTURE METHODS ACCORDING TO ISO 7704 XEBIOS DIAGNOSTICS GMBH

21.4 Recombinant DNA technology Calculation worksheet. AQA Biology. Calculating the efficiency of DNA transfer during genetic engineering

Lab Exercise: Examining Water Quality: Most Probable Number & Colilert Test Kit Lab

Validation Guide USTR 2114 (2) Validation Guide for Pall Emflon PFR Filter Cartridges

Environmental. National Legionella Conference Sample Taking Workshop. Right Solutions Right Partner

Biosand filters in schools: can they be restarted after abandonment over the long holidays?

Microbial measurement the inconvenient truth

3M Microbiology. Food safety. maximized. Safety. Processing

MICROBES are microorganisms that are ever present

BASIC MICROBIOLOGY HANDOUT 2

FDA s Guidance for Industry

Water quality Enumeration of Legionella

THANKS TO T.C. SOLI, Ph.D. T. C. Soli, President, Consulting & Training Services since 2004 after 25 years in big pharma

Evaluation of the genesig q16 quantitative PCR unit

Dentistry Test methods for dental unit waterline biofilm treatment

Guidance. Media Fills for Validation of Aseptic Preparations for Positron Emission Tomography (PET) Drugs DRAFT GUIDANCE

Immobilization and Death of Bacteria by Flora Seal Microbial Sealant

INTRODUCTION water-soluble Figure 1.

Automated methods in the Microbiology Lab-Issues and Troubleshooting! Presented By: Dr B. Oboudi

Microbiologic Sampling of the Environment

Quality Control Microorganism Product Guide. Convenience with Confidence

Background Legionella bacteria 4/13/2017. The Impact of The ASHRAE Standard for Legionella Control In Building Water Systems.

MANNITOL SALT AGAR 1/5

Hot Topics in Drug Product Process Validation: A Reviewer s Perspective

Rapid Microbiological Methods Understanding the Technologies and Regulatory Expectations for Validation and Implementation

Adapted from Biology 15 Laboratory Manual Supplement: Wrightsman, Ininns and Cannon-Moloznic, Saddleback College, CA 92692

BBL QualiSwab Quality Control Culture Devices

PRESERVATIVE EFFICACY TEST FOR COSMETIC PRODUCT

Microbiological Standards for Reusable Plastic Containers within Produce Grower Facilities

BACTERIA SENSITIVE TO NUTRIENT BROTH MEDIUM IN TERRESTRIAL ENVIRONMENTS

Inoculate: Media. Physical State of Media: Liquid. The Five I s: Basic Techniques to Culture Microbes Tools of the Microbiology Laboratory

CERTIFICATE OF ACCREDITATION

Compounding Pharmacies and Water

Study Summary. Results: All tested media-filled vials were negative for growth of any microorganisms.

MICROBIOLOGICAL CULTURE MEDIA

PURE CULTURE TECHNIQUES

The Biology of Composting

Transcription:

[PPT PDF] Pharmaceutical Water System Design Validation - Microbial Testing of Water is discussed in detail in this article. Pharmaceutical Water System: Classical Culture Approach for microbial testing of water Classical culture approaches for microbial testing of water include but are not limited to pour plates, spread plates, membrane filtration, and most probable number (MPN) tests. These methods are generally easy to perform, are less expensive, and provide excellent sample processing throughput. Method sensitivity can be increased via the use of larger sample sizes. This strategy is used in the membrane filtration method. Culture approaches are further defined by the type of medium used in combination with the incubation temperature and duration. This combination should be selected according to the monitoring needs presented by a specific water system as well as its ability to recover the microorganisms of interest: those that could have a detrimental effect on the product or process uses as well as those that reflect the microbial control status of the system. There are two basic forms of media available for traditional microbiological analysis: high nutrient and low nutrient. High-nutrient media such as plate count agar (TGYA) and m-hpc agar (formerly m-spc agar), are intended as general media for the isolation and enumeration of heterotrophic or copiotrophic bacteria. Low-nutrient media such as R2A agar and NWRI agar (HPCA), may be beneficial for isolating slow growing oligotrophic bacteria and bacteria that require lower levels of nutrients to grow optimally. Often some facultative oligotrophic bacteria are able to grow on high nutrient media and some facultative copiotrophic bacteria are able to grow on low-nutrient media, but this overlap is not complete. Lownutrient and high-nutrient cultural approaches may be concurrently used, especially during the validation of a water system, as well as periodically thereafter. This concurrent testing could determine if any additional numbers or types of bacteria can be preferentially recovered by one of the approaches. If so, the impact of these additional isolates on system control and the end uses of the water could be assessed. Also, the efficacy of system controls and sanitization on these additional isolates could be assessed. Duration and temperature of incubation are also critical aspects of a microbiological test method. Classical methodologies using high nutrient

media are typically incubated at 30 to 35 for 48 to 72 hours. Because of the flora in certain water systems, incubation at lower temperatures (e.g., 20 to 25 ) for longer periods (e.g., 5 to 7 days) can recover higher microbial counts when compared to classical methods. Low-nutrient media are designed for these lower temperature and longer incubation conditions (sometimes as long as 14 days to maximize recovery of very slow growing oligotrophs or sanitant injured microorganisms), but even high-nutrient media can sometimes increase their recovery with these longer and cooler incubation conditions. Whether or not a particular system needs to be monitored using high- or low-nutrient media with higher or lower incubation temperatures or shorter or longer incubation times should be determined during or prior to system validation and periodically reassessed as the microbial flora of a new water system gradually establish a steady state relative to its routine maintenance and sanitization procedures. The establishment of a steady state can take months or even years and can be perturbed by a change in use patterns, a change in routine and preventative maintenance or sanitization procedures, and frequencies, or any type of system intrusion, such as for component replacement, removal, or addition. The decision to use longer incubation periods should be made after balancing the need for timely information and the type of corrective actions required when an alert or action level is exceeded with the ability to recover the microorganisms of interest. The advantages gained by incubating for longer times, namely recovery of injured microorganisms, slow growers, or more fastidious microorganisms, should be balanced against the need to have a timely investigation and to take corrective action, as well as the ability of these microorganisms to detrimentally affect products or processes. In no case, however, should incubation at 30 to 35 be less than 48 hours or less than 96 hours at 20 to 25. Normally, the microorganisms that can thrive in extreme environments are best cultivated in the laboratory using conditions simulating the extreme environments from which they were taken. Therefore, thermophilic bacteria might be able to exist in the extreme environment of hot pharmaceutical water systems, and if so, could only be recovered and cultivated in the laboratory if similar thermal conditions were provided. Thermophilic aquatic microorganisms do exist in nature, but they typically derive their energy for growth from harnessing the energy from sunlight, from oxidation/reduction reactions of elements such as sulfur or iron, or

indirectly from other microorganisms that do derive their energy from these processes. Such chemical/nutritional conditions do not exist in high purity water systems, whether ambient or hot. Therefore, it is generally considered pointless to search for thermophiles from hot pharmaceutical water systems owing to their inability to grow there. The microorganisms that inhabit hot systems tend to be found in much cooler locations within these systems, for example, within use-point heat exchangers or transfer hoses. If this occurs, the kinds of microorganisms recovered are usually of the same types that might be expected from ambient water systems. Therefore, the mesophilic microbial cultivation conditions described later in this chapter are usually adequate for their recovery. Instrumental Approaches for microbial testing of water : Pharmaceutical Water System Examples of instrumental approaches include microscopic visual counting techniques (e.g., epifluorescence and immunofluorescence) and similar automated laser scanning approaches and radiometric, impedometric, and biochemically based methodologies. These methods all possess a variety of advantages and disadvantages. Advantages could be their precision and accuracy or their speed of test result availability as compared to the classical cultural approach. In general, instrument approaches often have a shorter lead time for obtaining results, which could facilitate timely system control. This advantage, however, is often counterbalanced by limited sample processing throughput due to extended sample collection time, costly and/or labor-intensive sample processing, or other instrument and sensitivity limitations. Furthermore, instrumental approaches are typically destructive, precluding subsequent isolate manipulation for characterization purposes. Generally, some form of microbial isolate characterization, if not full identification, may be a required element of water system monitoring. Consequently, culturing approaches have traditionally been preferred over instrumental approaches because they offer a balance of desirable test attributes and post-test capabilities. Suggested Methodologies : Pharmaceutical Water System The following general methods were originally derived from Standard Methods for the Examination of Water and Wastewater, 17th Edition,

American Public Health Association, Washington, DC 20005. Even though this publication has undergone several revisions since its first citation in this chapter, the methods are still considered appropriate for establishing trends in the number of colony-forming units observed in the routine microbiological monitoring of pharmaceutical waters. It is recognized, however, that other combinations of media and incubation time and temperature may occasionally or even consistently result in higher numbers of colony-forming units being observed and/or different species being recovered. The extended incubation periods that are usually required by some of the alternative methods available offer disadvantages that may outweigh the advantages of the higher counts that may be obtained. The somewhat higher baseline counts that might be observed using alternate cultural conditions would not necessarily have greater utility in detecting an excursion or a trend. In addition, some alternate cultural conditions using low-nutrient media tend to lead to the development of microbial colonies that are much less differentiated in colonial appearance, an attribute that microbiologists rely on when selecting representative microbial types for further characterization. It is also ironical that the nature of some of the slow growers and the extended incubation times needed for their development into visible colonies may also lead to those colonies being largely nonviable, which limits their further characterization and precludes their subculture and identification.

Methodologies that can be suggested as generally satisfactory for monitoring pharmaceutical water systems are as follows. However, it must be noted that these are not referee methods nor are they necessarily optimal for recovering microorganisms from all water systems. The users should determine through experimentation with various approaches which methodologies are best for monitoring their water systems for in-process control and quality control purposes as well as for recovering any contraindicated species they may have specified. Pharmaceutical Water System: Drinking Water: POUR PLATE METHOD OR MEMBRANE FILTRATION METHOD1 Sample Volume 1.0 ml minimum2 Growth Medium Plate Count Agar3 Incubation Time 48 to 72 hours minimum Incubation Temperature 30 to 35 Purified Water: POUR PLATE OR MEMBRANE FILTRATION METHOD1 Sample Volume 1.0 ml minimum2 Growth Medium Plate Count Agar3 Incubation Time 48 to 72 hours minimum Incubation Temperature 30 to 35 Water for Injection: MEMBRANE FILTRATION METHOD

Sample Volume 100 ml minimum2 Growth Medium Plate Count Agar3 Incubation Time 48 to 72 hours minimum Incubation Temperature 30 C to 35 C 1 A membrane filter with a rating of 0.45 µm is generally considered preferable even though the cellular width of some of the bacteria in the sample may be narrower than this. The efficiency of the filtration process still allows the retention of a very high percentage of these smaller cells and is adequate for this application. Filters with smaller ratings may be used if desired, but for a variety of reasons the ability of the retained cells to develop into visible colonies may be compromised, so count accuracy must be verified by a reference approach. 2 When colony counts are low to undetectable using the indicated minimum sample volume, it is generally recognized that a larger sample volume should be tested in order to gain better assurance that the resulting colony count is more statistically representative. The sample volume to consider testing is dependent on the user's need to know (which is related to the established alert and action levels and the water system's microbial control capabilities) and the statistical reliability of the resulting colony count. In order to test a larger sample volume, it may be necessary to change testing techniques, e.g., changing from a pour plate to a membrane filtration approach. Nevertheless, in a very low to nil count scenario, a maximum sample volume of around 250 to 300 ml is usually considered a reasonable balance of sample collecting and processing ease and increased statistical reliability. However, when sample volumes larger than about 2 ml are needed, they can only be processed using the membrane filtration method. 3 Also known as Standard Methods Agar, Standard Methods Plate Count Agar, or TGYA, this medium contains tryptone (pancreatic digest of casein), glucose and yeast extract.