RHEOLOGICAL PROPERTIES ROSAND RH2000 RHEOLOGICAL INSTRUMENTS BACKED WITH RHEOLOGICAL EXPERIENCE

Similar documents
RHEOLOGICAL PROPERTIES ROSAND RH7 & RH10 RHEOLOGICAL INSTRUMENTS BACKED WITH RHEOLOGICAL EXPERIENCE

Polymers and plastics

HIGH PRESSURE CAPILLARY RHEOMETERS RHEOGRAPH 20, 25, 50, 75, 120

Five compelling reasons to replace sieve analysis with laser diffraction

Optimizing Rheology for Paint and Coating Applications

Adeno-Associated Virus titer and aggregation characterization

Particle size analysis of cement using the technique of laser diffraction

3.5.7 Flow Through Simple Dies

Determining fluorescence Limit of Detection with Nanoparticle Tracking Analysis (NTA)

Melt tension measurement (Haul-Off)

Rheological Studies on Radiation Modified Polyethylene Resins. Song Cheng* and Ed Phillips

MICROCAL PEAQ-DSC BIOMOLECULAR STABILITY ANALYSIS FOR THE REGULATED ENVIRONMENT LABEL-FREE ANALYSIS MICROCALORIMETRY

Monitoring Microfiltration Processes for Water Treatment

zahnrad_neu_gb :46 Uhr Seite 1 Gear Pumps

PREPARED BY: DR. RAHIMAH OTHMAN FOOD ENGINEERING (ERT 426) SEMESTER 1 ACADEMIC SESSION 2016/17

Rheological Indicators to Predict the Extrusion Coating Performance of LDPE. Per-Åke Clevenhag and Claes Oveby Tetra Pak Carton Ambient AB ABSTRACT

Examination of the Performance of a High Speed Single Screw Extruder for Several Different Extrusion Applications

Extrusion. Key Issues to Address. Lecture 2. Process. Process Variants. Process Analysis. Problem Solving

Performance and productivity.

THE EFFECTS OF VISCOELASTIC BEHAVIOR ON COATING

ESTIMATION OF ELONGATIONAL VISCOSITY OF POLYMERS FOR ACCURATE PREDICTION OF JUNCTURE LOSSES IN INJECTION MOLDING

Direct visualization, sizing and concentration measurement of fluorescently labeled nanoparticles using NTA

Characterisation of the flow properties of filled materials and update on standards

Versatile Research Heat Exchanger

Influence of extrusion coating processing conditions on structure and tensile properties of some polyethylene grades

Rheological Techniques for Yield Stress Analysis

Flow Behaviour and Viscoelasticity of Polypropylene-Kaolin Composites Extruded at Different Temperatures

CRIMP TOOLING WHERE FORM MEETS FUNCTION

Calcium Carbonate in Blown HDPE Film

Thermoforming packaging machine R 145 with MULTIVAC Clean Design. Maximum process reliability and cleanroom suitability

How Will It Mold? Brand-New Test Method Relates Material, Mold & Machine. feature mold design

Lab Scale Bicomponent Extruder Fed Spinning Machine Model LBS

Infrared Temperature Measurement Systems. Designed for the Aluminium Extrusion Industry

Drop Weight Impact Testing Machine DIT183E 1800J

Contents. 1. Introduction to Materials Processing Starting Materials 21. Acknowledgements

MECHANICS OF PASTE FLOW IN RADIAL SCREEN EXTRUDERS

Understanding Extrusion

Endex Foam Extrusion General Information Guide

Thermal and Rheological Evaluation of Pharmaceutical Excipients for Hot Melt Extrusion

A Novel Extrusion Microns Embossing Method of Polymer Film

Lubricating grease shear flow and boundary layers in a concentric. cylinder configuration

A class of its own JUMAG STEAM BOILER COMPACT INFORMATION STEAM BOILER WATER SUPPLY MODULES BLOW DOWN VESSEL COMPACT STEAM SYSTEM.

exceptional DesiGn enhanced performance DMA 8000 Dynamic Mechanical Analyzer

Processing PET bottle flakes into nonwovens with fully-automatic filtration and online IV monitoring Dr. Monika Gneuss Gneuss Kunststofftechnik GmbH

3. Mechanical Properties of Materials

Sensortherm. Digital Pyrometer. Temperature Measurement and Control. com

3M Electrically Conductive Adhesive Transfer Tape 9707

Product Capacity of HDPE plant

PoDFA The complete solution for inclusion measurement Inclusion identification and quantification analysis

Products Capacity of HDPE plant

Combustion Laboratory Unit C492

DIE FLOW CHANNEL DISTRIBUTION

Our technology makes an impact. BIG-MIX Model 35 Model 48 Model 60 Model 80 Model 110 Model 120. PUMPE BIG-Mix 1

Dekati. ELPI Electrical Low Pressure Impactor. Real-time particle size distribution Wide particle size range Wide range of applications

Pinnacle Automation, LLC

SCREW & BARREL METALLURGY & SERVICE LIFE. Mrunal Sanghvi Regional Sales Manager Nordson Xaloy Asia (Thailand) Ltd.

Test instruments for paints and coatings

Diaphragm seal with flange connection With internal diaphragm Model

Separation and Purification Sciences Division. Betapure AU Series Rigid Filter Media Cartridges

TAILORING THE RHEOLOGY OF AQUEOUS ACRYLIC PSA-DISPERSIONS

Thermo Scientific Twin-Screw Extruders Comprehensive Compounding and Extrusion Solutions for Materials Science

New bio-based rheological additives for low-temperature process

Size quality report for the Zetasizer Nano

A MODEL FOR RESIDUAL STRESS AND PART WARPAGE PREDICTION IN MATERIAL EXTRUSION WITH APPLICATION TO POLYPROPYLENE. Atlanta, GA 30332

In the world market for 25 years...

Gelimat Technology. Ultrahigh-Speed Thermokinetic Mixing, Compounding & Fluxing. Processing Excellence in Motion DUSATEC DUSATEC, INC.

Determining Asphalt Binder Bond Strength by Means of the Binder Bond Strength (BBS) Test

CELCON M25 POM Unfilled

P. Pereira, C. N. Barbosa, J. C. Viana. University of Minho, Portugal

SIZE REDUCTION TECHNOLOGY

Compounding and Processing Additives for Woodfiber-Plastic Composites

Polymers and Plastics Technology Handbook

INTRODUCTION. Table 1. Typical applications for LDPE and Ateva EVA copolymers. Category Typical Applications Advantages

X-RAY FOOD INSPECTION SYSTEMS DYMOND X-RAY INSPECTION SYSTEM

ISO 4575 INTERNATIONAL STANDARD. Plastics Poly(vinyl chloride) pastes Determination of apparent viscosity using the Severs rheometer

Development of Advanced Structural Foam Injection Molding. Kye Kim. A thesis submitted in partial fulfillment of the requirements for the degree of

APN029. The SER2 Universal platform for material testing. A.Franck TA Instruments Germany

special hot work tool steel CR7V-L

MonTech RP 3000 Rapid Plastimeter for Polymers and Natural Rubber

Magnesium hydroxide [Mg(OH)2] Application Data Sheet for Ethylene-Vinyl Acetate copolymer (EVA)

Laser Sintering Solutions

BLOW MOULDING. Blow moulding is a process used to produce hollow objects from thermoplastic.

SCION GC Series. The Gas Chromatographers Choice for Separations

Journal of Advances in Agricultural Science and Technology

Sullair Water Chillers. Precision Chilled Water

High Density Polyethylene (HDPE) As a Marine Material. Written by: Tobias Clarke

Co-Rotating Twin-Screw Extruder Herausgegeben von Klemens Kohlgrüber

LARGE CAPACITY IN A COMPACT AND ERGONOMIC FORMAT FIXED TABLE TRAVELLING COLUMN MILLING MACHINES SLP

introduction Introduction.1 contents Irrigation Warehouse Group Pty Ltd Ph

Advances in Twin Screw Compounding Technology

Brochure. Equator gauging systems

Ultimate Flexibility enhance your material development. Thermo Scientific HAAKE PolyLab Modular torque rheometer platform

Practical 2P6 Extrusion

COMPARISON OF CAST FILM AND BLOWN FILM 9 - LAYER BARRIER FILM

Binder Optimization for the Production of Tungsten Feedstocks for PIM

SUCCIPACK Development of active, intelligent and sustainable food PACKaging using Polybutylenesuccinate

OPTIMA EXTRUDER. The next generation Single Screw Extruder for Petfoods and Aquatic Feeds.

MSE-226 Engineering Materials

Relative humidity as a new parameter in rheological testing

Laboratory-Platen-Presses Types P/M

Transcription:

RHEOLOGICAL PROPERTIES ROSAND RH2000 RHEOLOGICAL INSTRUMENTS BACKED WITH RHEOLOGICAL EXPERIENCE

ADVANCED BENCH-TOP CAPILLARY RHEOMETERS FOR RESEARCH, PRODUCT DEVELOPMENT AND QUALITY CONTROL The RH2000 series of bench top capillary rheometers are compact systems capable of most testing requirements encountered in capillary rheometry. The series is available in both single bore or twin bore configurations, the RH2100 and RH2200 respectively. Both versions incorporate many of the features and attributes found in the floor standing models (Rosand RH7&10). A new digital drive system gives the RH2000 series unsurpassed speed control, accuracy, and dynamic operating range. This new hardware is supported by the latest generation of Windows based software, Flowmaster, offering many new experimental possibilities. 2 www.malvern.com

KEY FEATURES AND BENEFITS Rosand Twin Bore Principle (RH2200 model) Rosand capillary rheometers were the first to introduce the twin bore measurement principle to the commercial market. Simultaneous measurements can be made on both long and short dies to determine the inlet pressure drop at the die and, therefore, absolute viscosity, using the Bagley method. More commonly, Rosand zero length dies are used to directly measure the inlet pressure drop and measure the extensional viscosity using the Cogswell method. The twin bore technique gives obvious experimental advantages including improved throughput, since both experiments are preheated simultaneously. Alternatively, the software can be configured to run a two material test which allows measurement of the viscosity of two different materials simultaneously. Rigid frame design Rigid one-piece cantilever frame design provides extreme mechanical strength and stiffness for a compact bench top unit. Swivel head design A unique, safety interlock protected, swivel design means that the actuated part of the rheometer can be moved to one side affording ease of access for cleaning and sample loading. Bi-modal speed control Bi-modal digital speed control technology has been developed for the latest generation of capillary rheometers. The technology uses different speed control algorithms suited to high and low speed operation to optimize performance. This gives the rheometer an impressive dynamic range in speed control. In practice, the lower limit is determined only by long experimental times at low shear rates but a dynamic range in speed of in excess of 200,000:1 is available if required. This greatly enhances the system s flexibility and means that a wider range of shear rates can be covered using any particular die. 3

FLOWMASTER SOFTWARE Continuous development of the Rosand Flowmaster software has produced a comprehensive data acquisition and analysis package with a wide range of measurement options and an extensive help system. Constant shear and extensional tests Measurement of shear or extensional stress and shear or extensional viscosity as a function of shear rate. Extensional tests are carried out with an orifice die. Die swell Measurement of the extrudate diameter close to the die exit. Directly interfaced with the control software and die swell is stored as part of the measurement data file. Melt fracture/flow instability Accelerated shear rate ramp with continuous monitoring of the pressure to detect flow instabilities, such as melt fracture which may occur during flow through a capillary die. Software modules and analysis functions include: Software options Constant shear test Extensional test Manual control Flow/no flow Non-Newtonian index Bagley correction by orifice die and extrapolation methods Rabinowitsch correction Hagenbach correction for fluid inertia Cogswell convergent flow model and extensional viscosity assessment Extensive plot and print options Data export Wall slip analysis Melt fracture/flow instability Die swell Material degradation/thermal stability Low speed degradation Eta-0 (Intrinsic Melt Viscosity) Stress relaxation Low level scripting 4 www.malvern.com

OPTIONS The Rosand RH2000 capillary rheometers can be configured with a variety of options to provide complete measurement solutions across all applications. High Force Extends the maximum force (summed over both barrels if applicable) to 20kN. High Speed Extends the upper speed limit of the unit to 1200mm/min for high shear rate measurement with no loss in speed sensitivity or available force. The high speed option is fully compatible with the high force option. Barrel Materials and Dimensions For aqueous or aggressive materials, stainless steel or Hastelloy barrels are available in place of the standard Nitrided steel version. The wide dynamic range in speed means that the standard 15mm diameter barrel is suitable for the vast majority of testing applications. However, barrels are available with 9.5mm, 12mm, 19mm and 24mm bores as an option. Low Temperature For applications that require sub-ambient measurements, a special cooling coil option is available. Accessories Several accessories are available to suit particular applications or enhance the testing capability of the base units. The main accessories are listed below Alternative test dies Alternative pressure transducers Nitrogen purge Die and melt cutters Laser die swell measurement 5

APPLICATIONS POLYMERS COATINGS CERAMICS METALS PHARMACEUTICALS SEALANTS FOODS INKS Characterization of polymer or suspension rheology across a range of shear rates and temperatures Simulation of extensional viscosity dominated processes such as fibre spinning, blow moulding, film blowing and thermoforming Assessment of extrusion behaviour for processes such as injection moulding and hot melt extrusion Evaluation of material behaviour at process relevant shear rates such as high speed coating and printing applications Detection of polymer instabilities such as melt fracture and thermal degradation Measurement of material elasticity and related properties such as die swell 6 www.malvern.com

RHEOMETER SPECIFICATIONS Overview Rosand RH2000 - Comprehensive rheological analysis Number of bores Maximum force Frame stiffness Maximum speed Dynamic range in speed Single (RH2100) Double (RH2200) 12kN standard (20kN option) 100kN 600mm/min standard (1200mm/min high speed option) >120000:1 (240000:1 with high speed option) Speed uncertainty <0.1% Temperature range Temperature control Bore diameter Barrel bore length Barrel material Pressure transducer ranges Ambient to 400ºC (500ºC option) 5ºC to 200ºC (Low temperature cooling coil option) <±0.1ºC 15mm standard (9.5, 12, 19 and 24mm bore options) 250mm Nitrided steel standard (Hastelloy or stainless steel options) 30000, 20000, 10000, 5000, 1500 or 500 psi Pressure transducer accuracy <0.5% Dies Die diameter Height Width Depth Weight Power requirements Tungsten carbide, precision ±5µm 0.5 to 2mm (in 0.5mm increments) and 3mm standard (other diameters, including fine bore dies, available to special order) Rheometer 1.1m Electronics box 0.65m Rheometer 0.55m (without accessories) Electronics box 0.34m Rheometer 0.65m (without accessories) Electronics box 0.53m Rheometer 120kg (without accessories) Electronics box 30kg Single phase AC 230V 50Hz 16A Rheological support made easy. Every Rosand RH2000 from Malvern is backed with the technical and sales support of Malvern Instruments, the only material characterization company with the resources and equipment to measure particle size and shape, zeta potential and molecular weight as well as the expertise to advise on how these parameters influence rheological properties. 7

Malvern Instruments Limited Grovewood Road, Malvern, Worcestershire, UK, WR14 1XZ Tel +44 1684 892456 Fax +44 1684 892789 www.malvern.com Malvern Instruments is part of Spectris plc, the Precision Instrumentation and Controls Company. Spectris and the Spectris logo are Trade Marks of Spectris plc. Malvern Solutions: Advanced technology made simple - distributor details All information supplied within is correct at time of publication. Malvern Instruments pursues a policy of continual improvement due to technical development. We therefore reserve the right to deviate from information, descriptions, and specifications in this publication without notice. Malvern Instruments shall not be liable for errors contained herein or for incidental or consequential damages in connection with the furnishing, performance or use of this material. Malvern and the hills logo and Rosand are International Trade Marks owned by Malvern Instruments Ltd. 2016 MRK0678-04