Kuhlman Electric Corporation Volt Instrument Transformers

Similar documents
SECTION HIGH EFFICIENCY DISTRIBUTION TRANSFORMERS

Standard of Practice - Campus Electrical Distribution System

SECTION MEDIUM VOLTAGE TRANSFORMERS

CONSOLIDATED EDISON COMPANY OF NEW YORK, INC Van Dam Street Long Island City, NY ELECTRIC METER SHOP DEPARTMENT

DISTRIBUTION TRANSFORMER SPECIFICATION #

B. Provide liquid-filled secondary substation transformers as indicated on drawings.

2/2 % ) Direct Acting Subminiature Solenoid Valves. 1/8" and 1/4" NPT. Features. Construction. Electrical

roduct Scope: Substation

Unit Price Labor. INSTALL 138KV DISCONNECT SWITCH WITH MOTOR OPERATOR AND AUXILIARY SWITCHES ON EXISTING STRUCTURE 1 ea.

Important Considerations for Specifying MV Mining Switchgear Western Mining Electrical Association Edmonton, Canada June 13, 2008

UNDERGROUND SERVICES SECONDARY

SECTION HEAT TRACING FOR PLUMBING PIPING

PLANNING GUIDE FOR SINGLE CUSTOMER SUBSTATIONS SERVED FROM TRANSMISSION LINES

S. C. Electric Cooperative s Specification for a Single-Phase, Two Bushing Overhead Distribution Transformer (Revised 10/2013)

Point Eight Power, Inc. Switchgear Specification Low Voltage UL 1558 Metal-Enclosed Switchgear

Narayan Group. Supplying to in countries. Blue- Manufacturing units Green- Supply countries. Export business & Total Business

6. SECONDARY SERVICES (under 600 volts) 6.1 AVAILABILITY For the electrical characteristics of available secondary services see Section 3.4.

Details of technical leaflets/write-up on various pieces of equipment.

Metering Requirements 750 Volts or Less

Switch Rack Assemblies

CLARK PUBLIC UTILITIES TECHNICAL SPECIFICATIONS SINGLE-PHASE PADMOUNTED TRANSFORMERS

SECTION GROUNDING AND BONDING FOR ELECTRONIC SAFETY AND SECURITY

thermoweld The Contractors Choice GREAT PRODUCTS GREAT SERVICE GREAT PEOPLE

INDUSTRIAL TEMPERATURE SENSORS

ELECTRICAL INSPECTION BULLETIN (Effective )

Customer Owned Meter Enclosures for Self-Contained Watthour Meters

OPERATING TEMP RANGE: -40 TO 80 C -40 TO 105 C with optional UL2722 lead wires

UFGS (August 2010) UNIFIED FACILITIES GUIDE SPECIFICATIONS

OPERATING PROCEDURE NO. 310

MPM 100 Monitor Product Description Guide

Fusing Equipment. Capacitor Expulsion Fuse FUSE TUBE DESIGN FEATURES EJECTOR SPRING DESIGN FEATURES

PLCC Sockets Through Hole - M43 Series

Title: YALE OFFICE OF FACILITIES PROCEDURE MANUAL Chapter: 01 - Yale Design Standard Division: Electrical Standards

Welcome to Douglas County PUD

4CS12 4CS-1/2 4X1-7/8D Handybox. Features. Dimensions and Weight. Long Description. Catalog Number

SECTION SUBSTATION BUS ASSEMBLIES ERGLE SUBSTATION

Title: YALE OFFICE OF FACILITIES PROCEDURE MANUAL Chapter: 01 - Yale Design Standard Division: Electrical Standards

DISTRIBUTION SILICONE INSULATORS Deadend / Suspension 15 kv to 69 kv

MV Product Specifications

A. This Section includes the following types of dry-type transformers rated 600 V and less, with capacities up to 1000 kva:

SECTION LOW-VOLTAGE SWITCHGEAR

Installation Instructions

DESIGN GUIDELINES WIRING AND CONDUITS PAGE 1 of 7

Wall studs. Wall Studs

Moulded Case Current Transformers

DOWNTOWN UNDERGROUND NETWORK SECONDARY SERVICES GUIDELINES

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017

Brugg Cables High Voltage Accessories. Swiss solutions for independent applications.

8.1.2 Under no circumstances shall a service entrance be left unmetered. Notify the Company if an unmetered service is encountered.

FAST POWER FACTOR REGULATOR. Computer-14df - xx - 144a INSTRUCTION MANUAL ( M / 00A ) (c) CIRCUTOR S.A.

ROLINX Laminated Busbar. Design Rules Version 01 (12/2015)

3M Cold Shrink Silicone Rubber Connector Insulators 8440 Series

ARC WELD STUDS & ARC STUD WELDING EQUIPEMENT

OVERHEAD SERVICE. Table of Contents - Section 400

Service Entrance Cable Fittings

CFFWA-20-1-U Chilled/Hot Water Universal Mount Fan Coil 2-Pipe Heat / Cool Fan Coil 60,000 BTUH

TABLE OF CONTENTS. Throughout the catalog you will notice blue highlighted items. These are the most frequently ordered BURNDY Products.

Installation Instructions Self-Regulating (sr) roof and gutter

CONSOLIDATED EDISON COMPANY OF NEW YORK, INC. 4 IRVING PLACE NEW YORK, NY ORANGE & ROCKLAND UTILITIES 390 WEST ROUTE 59 SPRING VALLEY, NY 10977

Power Zone Center. Your solution for power distribution and control systems

1-1/2 LB FM7 CND BD ELECTRO ZINC PLATED DICHROMATE EPOXY POWDER COATED

MGO INSULATED THERMOCOUPLES INDEX

Phone: Fax:

TABLE OF CONTENTS. Type HFB-P1... A-22. Type HFB-N... A-23. Types KA-U, KKA-U... A-24. Type K2A-U... A-25. Types K3A-U, KK3A-U...

2008 NEC Guide Lines for Home Owner Doing Electrical Work on their Property

Permitting and Inspecting PV Systems. PV Codes and Standards 101. Photovoltaic System Basics

(Condensed from National Electric Code)

NEC 2017 Code Changes Chapter 1 - General

Type FLX Freezer Floor Frost Heave Protection DESIGN GUIDE

nicrom e l e c t r o n i c

The complete guide to transformers and packaged substations

RoHS Compliant (6/6) according to Directive 2002/95/EC when ordered with 100% Sn solder.

Fixed Demand (Block Demand) The utility company sends a signal to synchronize the start of the Maximum Demand period.

About Matt Piantedosi

Install and commission high voltage (HV) electricity current transformer metering

SECTION 16496A MTS MANUAL TRANSFER SWITCH (MANUAL CONTROL ONLY) Note to Spec Writer: { } Denotes EATON Feature reference number

MHWW-09-H-1 Chilled/Hot Water Hi-Wall Fan Coil. Heat / Cool Fan Coil 9,000 BTUH. Rev. 1.3

General Information, Industrial Thermocouple Section

UNIVERSITY OF WASHINGTON Facilities Services Design Guide. Electrical. Medium Voltage Switchgear. Basis of Design.

660 Volts 630 & 800AMP

Schmidthammer. 06 High current carbon brushes. Elektrokohle GmbH. Transmission systems with linear adjustable telescope holders p.

Thermocouple Reference Table

DIVISION MEDIUM VOLTAGE VAULT DESIGN Contents MEDIUM VOLTAGE VAULT DESIGN... 2 DIVISION LIST OF FIGURES...

UNIFIED FACILITIES GUIDE SPECIFICATIONS

Flexible Printed Circuits Design Guide

BUSWAY LOW VOLTAGE (POW-R-WAY III) SECTION SECTION 16466

Fixings, bonds and clamps

1. Telecommunications mounting elements. 2. Backboards. 3. Telecommunications equipment racks and cabinets. 4. Grounding.

SnoTrace TM RGS TM Systems for Roof and Gutter Snow and Ice Melting

Contents. SuperPlate. Tubes Technology. Through Holes Technology. Milled Channels Technology. Thermal Analysis. SuperPlate

A. All materials shall be tested and listed by an OSHA approved Nationally Recognized Testing Laboratory (NRTL).

product specifications e

Will accommodate up to 35 conductors while maintaining separation required to withstand instrumentation voltages

DC-DC Converters MI-J00

Specifications for Residential Overhead Electric Service Installation

GENERAL USE VISE TYPE ALUMINUM SINGLE BOLT ALUMINUM TO ALUMINUM OR ALUMINUM TO COPPER

*** Supercedes: BECO E and COM , , & ***

SECTION GROUNDING AND BONDING

TECHNICAL SPECIFICATION FOR 11KV INDOOR/OUTDOOR & 22KV/33KV OUTDOOR METERING CUBICLE SPEC NO.CE (DIST)/MM-IV/09/ INDEX

Minimum Transmission Design Standards f or Competitive Upgrades Rev 2

Transcription:

Kuhlman Electric Corporation 5000 Volt Instrument Transformers

5000 Volt Table of Contents Description Model Page 3 ½ Window CT Single, Dual & Multi Ratio (High Accuracy Available) TD-994 3-4 3 ½ Window CT Single, Dual & Multi Ratio (High Accuracy Available) RMB(X)-631 5-6 Indoor, Wound, Dry-Type VT Y Burden U/VCD-7 7-8 Indoor, Wound, Dry-Type CT Standard Range CID-7 9-10 2

TD 994 Current Transformer Indoor/Outdoor 5kV, 60kV BIL, Single, Dual & Multi Ratios Molded Resin, Window Type, Metering/Relaying application The TD-994 indoor/outdoor, window-type current transformer is rated for use on 5,000 volt systems with 60kV BIL. Primary current ratios are available from 50:5 to 4000:5 at 60 Hertz (Hz) with a of up to 4.0. This dry-type, solid-cast current transformer will operate with high accuracy for metering or relay applications. 5000 Volt mechanical description The core and coil assembly is wound and encapsulated in a molded cast resin with a standard 3.44 window to provide high withstand capabilities. An optional primary bus bar with NEMA 4-hole pads can also be provided (4000A max). The secondary terminals are ¼ -20 copper studs with associated hardware located inside a removable terminal box with two (2) 1 NPT conduit hubs. accuracy performance The TD-994 will operate with 0.3 Class accuracy for metering with burdens of B0.1 to B1.8 and up to C400 for some relay applications. The transformer is accurate through its, and can be used continuously to this level. testing The unit is individually tested per the IEEE C57.13 standard, including applied and induced voltage, accuracy and polarity. Partial discharge testing is performed to guarantee the unit is free of partial discharge through 120% of the nominal system voltage. The unit is tested above operating voltage for traces of corona. A corona free label is bonded to the completed transformer as a guarantee of trouble-free service. mounting The TD is designed for mounting in an upright, underhung or cantilever position. Mounting slots are provided on the aluminum base. ORDERING INFO FOR TD-994 Ratio Catalog Number* Accuracy/Burden Metering Relay options The TD is available with a primary bus bar kit. The unit can be offered in single or dual core designs. Contact factory for other needs. HIGH ACCURACY N/A Catalog Number 0.15/0.3 @ Burden Accuracy Range 100:5 B130100S1 0.3 B0.1 C10 2.0 -- -- -- -- 200:5 B130200S1 0.3 B0.2 C20 2.0 -- -- -- -- 300:5 B130300S1 0.3 B0.2 C50 2.0 -- -- -- -- 400:5 B130400S1 0.3 B0.5 C75 2.0 -- -- -- -- 500:5 B130500S1 0.3 B0.5 C100 2.0 -- -- -- -- 600:5 B130600S1 0.3 B0.5 C100 2.0 -- -- -- -- 800:5 B130800S1 0.3 B0.9 C150 2.0 -- -- -- -- 1000:5 B131000S1 0.3 B1.8 C200 2.0 -- -- -- -- 1200:5 B131200S1 0.3 B1.8 C200 2.0 -- -- -- -- 1500:5 B131500S1 0.3 B1.8 C200 2.0 -- -- -- -- 2000:5 B132000S1 0.3 B1.8 C200 2.0 -- -- -- -- 2500:5 B132500S1 0.3 B1.8 C200 2.0 -- -- -- -- 3000:5 B133000S1 0.3 B1.8 C200 1.0 -- -- -- -- 4000:5 B134000S1 0.3 B1.8 C200 1.0 -- -- -- -- 200/400:5 B130200D1 0.3 B0.2/B0.5 C20/C40 2.0/2.0 -- -- -- -- 300/600:5 B130300D1 0.3 B0.2/B0.5 C50/C100 2.0/2.0 -- -- -- -- 400/800:5 B130400D1 0.3 B0.5/B0.9 C75/C150 2.0/2.0 -- -- -- -- 600/1200:5 B130600D1 0.3 B0.5/B1.8 C100/C200 2.0/2.0 -- -- -- -- 1000/2000:5 B131000D1 0.3 B1.8/B1.8 C100/C200 2.0/2.0 -- -- -- -- 1500/3000:5 B131500D1 0.3 B1.8/B1.8 C100/C200 2.0/1.0 -- -- -- -- 2000/4000:5 B132000D1 0.3 B1.8/B1.8 C100/C200 2.0/1.0 -- -- -- -- - Available in multi-ratio designs (full tap ratings same as single ratio above). - 1 Second Thermal/Mechanical s: 60x full winding I nom / Unlimited mechanical. - Available with a primary bar kit (maximum 4000A). Change last digit of catalog from 1 to 3. * IC Approval AE-1335 is noted by bold catalog number. 3

5000 Volt TD 994 Current Transformer 4 NOTE: OUTLINES ARE FOR REFERENCE ONLY. CONTACT FACTORY FOR ACTUAL DESIGN DRAWINGS.

RMB(X) 631 Current Transformer Indoor/Outdoor 5kV, 60kV BIL, Single, Dual & Multi Ratios Molded Resin, Window Type, Metering/Relaying application The RMB(X)-631 indoor/outdoor, window-type current transformer is rated for use on 5,000 volt systems with 60kV BIL. Primary current ratios are available from 200:5 to 4000:5 at 60 Hertz (Hz) with a of up to 4.0. This dry-type, solid-cast current transformer will operate with high accuracy for metering or relay applications. 5000 Volt mechanical description The core and coil assembly is wound and encapsulated in a molded cast resin with a standard 3 ½ window (other sizes from 2 to 6 ) to provide high withstand capabilities. An optional primary bus bar with NEMA 4-hole pads can also be provided (4000A max). The secondary terminals are ¼ -20 copper studs with associated hardware located inside a removable terminal box with two (2) 1 NPT conduit hubs. accuracy performance The RMB-631 will operate with 0.3 Class accuracy for metering with burdens of B0.1 to B1.8 and up to C800 for some relay applications. The transformer is accurate through its, and can be used continuously to this level. The RMBX-631 will operate with 0.15 Class high accuracy for metering applications with burdens of B0.1 to B1.8. The transformer maintains 0.3 accuracy from 1% of I nom through its, and can be used continuously to this level (for 0.15 accuracy range, see ratings specifi c to each ratio). mounting The RMB is designed for mounting in an upright, underhung or cantilever position. Open end slots are provided on the aluminum mounting legs. ORDERING INFO FOR RMB-631 Catalog Accuracy/Burden (3.5 ID) Ratio* Number* Metering Relay* testing The unit is individually tested per the IEEE C57.13 standard, including applied and induced voltage, accuracy and polarity. Partial discharge testing is performed to guarantee the unit is free of partial discharge through 120% of the nominal system voltage. The unit is tested above operating voltage for traces of corona. A corona free label is bonded to the completed transformer as a guarantee of trouble-free service. options The RMB is available with a primary bus bar kit. Contact factory for other needs. HIGH ACCURACY RMBX-631 Catalog 0.15/0.3 @ Number Burden 0.15/0.3 Acc Range 200:5 B180200S1 0.3 B0.2 C100 3.0 -- -- -- -- 300:5 B180300S1 0.3 B0.5 C200 3.0 -- -- -- -- 400:5 B180400S1 0.3 B0.9 C250 3.0 B180400X1 B0.5/B0.9 400/4 to 1200A 3.0 500:5 B180500S1 0.3 B1.8 C300 3.0 B180500X1 B0.5/B1.8 500/5 to 2000A 4.0 600:5 B180600S1 0.3 B1.8 C400 3.0 B180600X1 B0.9/B1.8 600/6 to 2400A 4.0 800:5 B180800S1 0.3 B1.8 C400 2.0 B180800X1 B0.9/B1.8 800/8 to 3200A 4.0 1000:5 B181000S1 0.3 B1.8 C400 2.0 B181000X1 B1.8 10 to 4000A 4.0 1200:5 B181200S1 0.3 B1.8 C400 2.0 B181200X1 B1.8 12 to 4800A 4.0 1500:5 B181500S1 0.3 B1.8 C400 2.0 B181500X1 B1.8 15 to 4500A 3.0 2000:5 B182000S1 0.3 B1.8 C400 2.0 B182000X1 B1.8 20 to 4000A 2.0 2500:5 B182500S1 0.3 B1.8 C400 2.0 -- -- -- -- 3000:5 B183000S1 0.3 B1.8 C800 2.0 -- -- -- -- 4000:5 B184000S1 0.3 B1.8 C800 1.5 -- -- -- -- 600:5 MR B180600M1 0.3 B1.8 C400 2.0 -- -- -- -- 1200:5 MR B181200M1 0.3 B1.8 C400 2.0 -- -- -- -- 2000:5 MR B182000M1 0.3 B1.8 C400 2.0 -- -- -- -- 3000:5 MR B183000M1 0.3 B1.8 C400 2.0 -- -- -- -- 4000:5 MR B184000M1 0.3 B1.8 C400 2.0 -- -- -- -- - Available in dual-ratio designs (ratings same as single ratio above, change catalog digit S to D ). * Units can also be supplied with C800 ratings (add -512 to the end of the catalog number). - 1 Second Thermal/Mechanical s: 80x full winding I nom / Unlimited mechanical. - Available with a primary bar kit (maximum 4000A). Change last digit of catalog from 1 to 3. 5

5000 Volt RMB(X) 631 Current Transformer 6 NOTE: OUTLINES ARE FOR REFERENCE ONLY. CONTACT FACTORY FOR ACTUAL DESIGN DRAWINGS.

U/VCD 7 Voltage Transformer Indoor 5kV, 60kV BIL, Single Ratios Molded Epoxy, Wound Type, Metering/Relaying application The U/VCD-7 indoor voltage transformer is rated for use on 5,000 volt systems with 60kV BIL. Primary voltage ratios are available from 20:1 to 40:1 for use on 5,000 volt systems, at 60 Hertz (Hz). This dry-type, solid-cast voltage transformer will operate with high accuracy for metering or relay applications. 5000 Volt mechanical description The core and coil assembly is wound and encapsulated in a high dielectric strength epoxy resin to provide high withstand capabilities. The primary terminal(s) are screw-type, tin-plated, for #12 to #8 AWG conductors. The clamp-type post secondary terminals have ¼ -20 slotted screws and associated hardware embedded in epoxy resin on the front side of the transformer. In addition, a ground terminal is provided near the secondary terminals on the base plate. accuracy performance The U/VCD-7 will operate with 0.3 Class accuracy for metering and relay applications with burdens of 0, W, X, M and Y. The transformer is accurate from 90% to 110% of rated primary voltage. mounting The U/VCD is designed for mounting inside switchgear or other indoor applications in an upright, underhung or cantilever position. testing The unit is individually tested per the IEEE C57.13 standard, including applied and induced voltage, accuracy and polarity. Partial discharge testing is performed to guarantee the unit is free of partial discharge through 120% of the nominal system voltage. options Units are available in single or double bushing models. Primary terminal(s) can be equipped with fuse clip(s) and fuse(s). The unit can be offered in switchgear format with primary terminal(s) toward the back. Contact factory for other needs. ORDERING INFO FOR U/VCD-7 Ratio Primary Secondary HIGH ACCURACY N/A Catalog Number* Accuracy/ Catalog Number Accuracy/ 1 Bushing 2 Bushing Burden 2 Bushing Only Burden 20:1 2400 120 B916G020S0 B916020S0 0.3 0,W,X,M,Y -- -- 30:1 3600 120 -- B916030S0 0.3 0,W,X,M,Y -- -- 35:1 4200 120 -- B916035S0 0.3 0,W,X,M,Y -- -- 40:1 4800 120 -- B916040S0 0.3 0,W,X,M,Y -- -- - Thermal Burden (Typical): 750VA. - Overvoltage : 1.1x cont. - For fuse clips, add a C per clip needed at the end of the catalog. - For fuses, add an F per fuse needed at the end of the catalog. * IC Approval AE-1378 noted by bold catalog number. 7

5000 Volt U/VCD 7 Voltage Transformer 8 NOTE: OUTLINES ARE FOR REFERENCE ONLY. CONTACT FACTORY FOR ACTUAL DESIGN DRAWINGS.

CID 7 Current Transformer Indoor 5kV, 60kV BIL, Single Ratios Molded Epoxy, Wound Type, Metering/Relaying application The CID-7 indoor current transformer is rated for use on 5,000 volt systems with 60kV BIL. Primary current ratios are available from 5:5 to 600:5 at 60 Hertz (Hz) with a of up to 1.5. This dry-type, solid-cast current transformer will operate with high accuracy for metering or relay applications. 5000 Volt mechanical description The core and coil assembly is wound and encapsulated in a high dielectric strength epoxy resin to provide high withstand capabilities. The primary terminals are fl at, tin-plated copper with standard NEMA 2-hole pattern suitable for various size conductors. The clamp-type post secondary terminals have ¼ - 20 slotted screws and associated hardware embedded in epoxy resin on the front side of the transformer. The ground terminal is provided near the secondary terminals on the base plate. accuracy performance The CID-7 will operate with 0.3 Class accuracy for metering with burdens of B0.1 to B0.5 and C50 for relay applications. The transformer is accurate through its, and can be used continuously to this level. mounting The CID is designed for mounting inside switchgear or other indoor applications in an upright, underhung or cantilever position. testing The unit is individually tested per the IEEE C57.13 standard, including applied and induced voltage, accuracy and polarity. Partial discharge testing is performed to guarantee the unit is free of partial discharge through 120% of the nominal system voltage. options Contact factory for other needs. ORDERING INFO FOR CID-7 Catalog Ratio Number* Accuracy/Burden Metering Relay HIGH ACCURACY N/A Catalog Number Accuracy/ Burden 5:5 B9150005S0 0.3 B0.5 C50 1.5 -- -- -- 10:5 B9150010S0 0.3 B0.5 C50 1.5 -- -- -- 15:5 B9150015S0 0.3 B0.5 C50 1.5 -- -- -- 20:5 B9150020S0 0.3 B0.5 C50 1.5 -- -- -- 25:5 B9150025S0 0.3 B0.5 C50 1.5 -- -- -- 30:5 B9150030S0 0.3 B0.5 C50 1.5 -- -- -- 40:5 B9150040S0 0.3 B0.5 C50 1.5 -- -- -- 50:5 B9150050S0 0.3 B0.5 C50 1.5 -- -- -- 75:5 B9150075S0 0.3 B0.5 C50 1.5 -- -- -- 100:5 B9150100S0 0.3 B0.5 C50 1.5 -- -- -- 150:5 B9150150S0 0.3 B0.5 C50 1.33 -- -- -- 200:5 B9150200S0 0.3 B0.5 C50 1.5 -- -- -- 300:5 B9150300S0 0.3 B0.5 C50 1.5 -- -- -- 400:5 B9150400S0 0.3 B0.5 C50 1.5 -- -- -- 500:5 B9150500S0 0.3 B0.5 C50 1.5 -- -- -- 600:5 B9150600S0 0.3 B0.5 C50 1.33 -- -- -- - 1 Second Thermal/Mechanical Minimum: 69x/186x I nom (37.8kA/102kA for above 300:5). Contact factory for actuals. * IC Approval AE-1392 noted by bold catalog number. 9

5000 Volt CID 7 Current Transformer 10 NOTE: OUTLINES ARE FOR REFERENCE ONLY. CONTACT FACTORY FOR ACTUAL DESIGN DRAWINGS.