Model 140MX Flowmeter Functional Overview

Similar documents
Target Inline Flowmeter

Pro-V Multivariable Flowmeter Model M23 Insertion Vortex

Pro-V Multivariable Flowmeter Model M23 Insertion Vortex

Sentinel LNG. Panametrics Ultrasonic Flowmeter for Cryogenic Liquids. GE Sensing & Inspection Technologies. Benefits. Applications

Battery-Powered Magnetic Flow Meter

Vortex EX DELTA lowmeter Technical Specifications

VERIS Accelabar. Superior Flow Measurement Accuracy

DIVA flowmeter. for saturated steam flow measurement

Rosemount 1152 Alphaline Nuclear Pressure Transmitter

Gilflo flowmeters. for steam, liquids and gases

KRAL Volumeter - OMG Series Universal Flowmeters

RHM80. High Flow Coriolis Mass Flow Meter. Features. Applications. Benefits

Data Sheet. Measuring System trikon Vortex Flow Meter EDZ 420 in Microprocessor Technology. Vortex meter trikon EDZ 420.

XMP i. Precision Pressure Transmitter for the Process Industry with HART -Communication. Stainless Steel Sensor

Flanged Water Meters (non-continuous flow)

Product Datasheet July Liquid Ultrasonic Flow Meters. Daniel 3812 Liquid Ultrasonic Flow Meter

XMP i. Precision Pressure Transmitter for the Process Industry with HART -Communication. Stainless Steel Sensor

SITRANS F X SITRANS F. Answers for industry. Vortex flowmeter The optimum measurement device for steam, gases and liquids

Rosemount 1154 Alphaline Nuclear Pressure Transmitter

Solar Flat Plate Thermal Collector

CH88 In Situ Flue Gas Oxygen Transmitter

F Series Flow Meter F300. User Manual

Plastic tube flowmeters Series PT/PS Variable area flowmeter for liquids and gases

OPTIMASS 7400 Technical Datasheet

DS-4018 English Rev. FA. ProPlate Flowmeter Mass ProPlate Flowmeter Model 1195 Integral Orifice

Rotameter. Series 134 glass tube variable area flowmeter. Data sheet Principle of operation. Philosophy. process measurement solutions

VENTURI FLOWMETERS. Your First Choice in Intelligent Flow Management...

Vortex Mass Flowmeter

VENTURI FLOW METER CALIBRATIONS SERIAL NUMBERS: , , , Prepared for. Imperial Flange and Fitting.

Insertion Flow Meters. The only hot tap Full Profile Insertion Flow Meter.

Technical Specifications and General Guidelines for Mass Flow Meters at Petroleum Oil Installations. Note:

Products Solutions Services. Vortex. Prowirl

FLUIDISTOR GAS FLOWMETER GD 100 (EX)

Alpha VSRD Multiphase Flowmeter

PARTS & ACCESSORIES: EATON DUPLEX BASKET STRAINERS FEATURES OPTIONS MODEL 53BTX DUPLEX (3/4 TO 4 ) MODEL 50 DUPLEX (5, 6, 8 )

Thermal Mass Flow Meters Help Reduce Energy Costs and Enhance Emissions Monitoring Systems

8.27/210 * 7.28/ / / /108. n x d. b f ML00343b. Dimensions are in inches/millimeters *8.86/225 for Pg 13.5 with adapter 2.

BM SERIES COMPACT GUIDE WAVE GUIDED WAVE RADAR LEVEL INSTRUMENTS

Vortex Flowmeter FV4000 (TRIO-WIRL V) Swirl Flowmeter FS4000 (TRIO-WIRL S)

VersaFlow Coriolis 1000 Mass Flow Sensor Specifications

Calculate the Costs of Piping System Elements

STANDARD TECHNICAL SPECIFICATION FOR ELECTROMAGNETIC FLOW METER with ACCESSORIES

x act i Precision Pressure Transmitter for Food Industry, Pharmacy and Biotechnology Stainless Steel Sensor accuracy according to IEC 60770: 0.

VersaFlow Coriolis 1000 Mass Flow Sensor Specifications

ABB Kent-Taylor. Turbine Meter PTF. PTF meter for guaranteed reliability and high accuracy in a turbine meter. Wide flow range up to 40:1

Liquid level switch BW 17

Permanent Pressure Loss Comparison Among Various Flowmeter Technologies

WP-SDC COPPER CAN REGISTER WOLTMAN WATER METER

Peerless Pump Company Handbook of Engineering Data

THE MICROFLOW SENSOR MICROFLOW SENSOR WITH A WIDE RANGE OF APPLICATIONS THANKS TO THE AVAILABILITY OF DIFFERENT CONNECTION TYPES

Shur-Shot X-Proof Hydrogen Fluoride Alarm Operations Manual

TVA Target Variable Area Flowmeter

heliflu tm The Dedicated Turbine Flowmeter for Custody Transfer Measurement Proven Performance Main Applications

VersaFlow Coriolis 6000 Sensor for Mass Flow Specifications

HELIFLU TM TZN. The Dedicated Turbine Flowmeter for Custody Transfer Measurement. Proven Performance. Main Applications

Industrial Solutions. Quality is Our Driving Force. interfaceforce.com

x act i Precision Pressure Transmitter for Food Industry, Pharmacy and Biotechnology Stainless Steel Sensor accuracy according to IEC 60770: 0.

ILMK 382. Stainless Steel Probe. Ceramic Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % FSO.

Regulating valves REG 6-65, REG-SS 15-40

Industrial Flowmeters

KEy FEATuRES. Virtually maintenance free. No interference from glycol, methanol or amine contaminants (vapor phase) Fast and accurate realtime

heliflu tm The Dedicated Turbine Flowmeter for Custody Transfer Measurement Proven Performance Main Applications

VersaFlow Coriolis 1000 Mass Flow Sensor Specifications

FGA 300 Panametrics Flue Gas Oxygen Analyzer. GE Sensing. Features. Applications

QSE MAG FLOW METER OM SERIES OVAL GEAR METER. Water Water-Based Liquid Solutions. Oils Molasses

ZDM POSITIVE DISPLACEMENT FLOW METER

QSE MAG FLOW METER OM SERIES OVAL GEAR METER. Water Water-Based Liquid Solutions. Oils Molasses

TEMPERATURE SWITCHES AND THERMOSTATS

Flowmeters. Positive Displacement meter. Coriolis mass flowmeter. Turbine flowmeter. Ultrasonic flowmeter

Fractional Pressure Gauge Heavy Duty Pressure Gauge Homogenizer Pressure Gauge High Accuracy Pressure Transmitter Homogenizer Pressure Transmitter

DIRECT READING FLOWMETERS FOR LIQUIDS AND GASES ISO-9001 CERTIFICATED FIRM

Flow Test Data Book and Flow Handbook for 405 Compact Orifice Series and 1595 Conditioning Orifice Plate

GUIDANCE NOTE. Performance of Electromagnetic Meters Designed for Use in Part-Filled Pipes.

Superior Performance. Vortex Shedding Products

Dorot Irrigation Meter

Float Flow Meters series NF

Index. Hydraulic Data Chapter 1. Formulas & Conversions Chapter 2. Friction Loss Chapter 3. Viscous Fluids & Slurries Chapter 4

NUFLO Liquid Turbine Flow Meters

Pressure transducers DMU 02 Vario (flush)

Industrial Electrolytic Conductivity Cells for UDA2182 Series and APT Series

February 5, 2013 Roy Ratcliffe, President RM Controls, Inc.

Red Eye Multiphase Water-Cut Meter

Utility Flow Metering for Steam and Heated/Chilled Water: A Tutorial. Richard Gruskos Flow Products Manager Kessler Ellis Products

NRF CAPACITANCE LEVEL TRANSMITTER

S E N S O R D A T A S H E E T. Extreme Environment. For high pressure, low temperature, and high temperature applications

Model B. Thermostatic Control Valves. Typical applications

nicrom e l e c t r o n i c

Turbidity Colour Oil in Water Water in Oil Oil on Water Ultrasonic Particle Monitoring

APlus-QMC LLC. Catalog 2017

Long-term Evaluation of Ultrasonic Flowmeters

Certified according to DIN EN ISO 9001 Technical Datasheet TRICOR Series Mass Flow Meters

Model 1159 Remote Diaphragm Seals

Flow Meter Hire QUICK REFERENCE GUIDE

SECTION PRESSURE AND DIFFERENTIAL PRESSURE GAUGES

Fuji Electric France S.A. DIFFERENTIAL PRESSURE (FLOW) TRANSMITTER FEATURES SPECIFICATIONS FKC...5 DATA SHEET. Functional specifications.

Selection Guide for Conductivity Cells and Compensators 4973 Should be quoted whenever possible for constants 0.01 to 10 cm -1.

YARWAY HANCOCK CONTINUOUS BLOWDOWN GLOBE VALVE SERIES 5505

R-100 Series GLASS TUBE FLOWMETER SIMPLE, BUT RELIABLE BEST COST PERFORMANCE GENERAL FEATURES MODEL CODE

1301 Series High-Pressure Regulators

Transcription:

A higher level of performance Model 14MX Flowmeter Functional Overview DESCRIPTION The Model 14MX Flowmeter (Figure 1) works on the fluid phenomenon of momentum exchange (see page 6 for details), providing accurate flow measurement for difficult to handle, high viscosity, and/or low flowrate applications. It features: Accurate and repeatable flow measurement High turndown (typically 12 to 1) No moving parts to damage or wear Withstands flow overranges of up to 4% of full scale Two-wire transmitter or remote signal converter for installation flexibility No meter body calibration shift, minimizing maintenance requirements Output linear with flowrate Rugged and reliable sensors Highly immune to shock and vibration No piping run requirements, simplifying installation The Model 14MX consists of a meter body and a twowire transmitter; a remotely-mounted signal converter is also available as an alternative to the two-wire transmitter. The rugged meter body includes a selfcontained strain gage sensor for direct, in-line installation into new or existing piping. The Model 14MX Flowmeter is constructed to resist harsh industrial environments. It can be subjected to flow overranges and the resulting pressure surges of up to 4% of full scale with no damage to the meter body or sensor and no shift in calibration. The Model 14MX Flowmeter also contains no moving parts, which minimizes maintenance and service needs. This design eliminates the need for costly, periodic meter recalibration. In addition, there are no gears that can bind or jam, resulting in interruption of flow. The design of the 14MX does not require a maintained turbulent flow in the pipe for operation. This allows it to be used with high viscosity fluids and/or low flowrates. It operates within its specified accuracy at Reynolds Numbers as low as 4 and will continue to provide an output signal at Reynolds Numbers as low as 75. Fluids with viscosities up to 8 centistokes can be metered. FIGURE 1 Model 14MX Flowmeter The Model 14MX Flowmeter is well suited for use with viscous fluids, such as fuel oils #2 through #6, and has proven itself in combustion applications, metering of hot/cold mixes, and sensor coating problems could be encountered. PERFORMANCE SPECIFICATIONS METER BODY Accuracy +2% of flowrate. Includes the combined effects of conformity, hysteresis, deadband, and repeatability errors. Table 1 lists minimum required Reynolds Number for stated accuracy. TABLE 1 Minimum Reynolds Number Meter Size (in/mm) R D Number ¾ (19) 4 1 (25) 5 1 ½ (38) 5 The Reynolds Number (R D ) is based on pipe diameter and can be determined from the following equation: R D = VD v R D = Reynolds Number V = Velocity in ft/s or m/s D = Actual inside pipe diameter in ft or m v = Kinematic viscosity in ft 2 /s or m 2 /s

For convenience, R D can be determined from the following hybrid equation: R D = 3162 (GPM) (Pipe ID. In.) (Centistokes) Repeatability.25% of flow rate Ambient Temperature Effect 1% of flowrate per 167 C (3 F) Flow Overrange Protection Flow overranges of up to 4% of full scale will not damage the meter body or the sensor. Position Effect The flowmeter can be mounted in horizontal, vertical, or inclined pipelines having an upwards direction of flow with no effect on performance. It is important that the pipe be kept full of fluid for accurate flow measurement. Minimum Flowrates ¾ (19 mm) Meter:.35 GPM/ Sp. Gr. or.2 GPM/cSt, whichever represents the larger flowrate of the fluid being measured 1 (25 mm) Meter:.75 GPM/ Sp. Gr. or.4 GPM/cSt, whichever represents the larger flowrate for the fluid being measured 1 ½ (39mm) Meter: 2 GPM/ Sp. Gr. or.1 GPM/cSt, whichever represents the larger flowrate for the fluid being measured. Minimum Flowrate vs. Liquid Viscosity Figures 2 through 4 depict the effect of viscosity on the minimum linear flowrate and minimum operating flowrate. As the viscosity increases above 2 cst, the minimum flowrate also increases. Kinematic Viscosity (cst) 8 6 4 2 3.3 FIGURE 2 Minimum Flowrate vs. Liquid Viscosity for ¾ (19 mm) Meter R D = 75 Non-Operating R egion R D = 4 Non-Linear Region Accuracy = 2% of Rate.35 2 4 6 8 Kinematic Viscosity (cst ) Kinematic Viscosity (cst) 8 6 4 2 8 6 4 2 FIGURE 3 Minimum Flowrate vs. Liquid Viscosity for 1 (25 mm) Meter R egion Non-Operating.75 5 1 15 2 FIGURE 4 Minimum Flowrate vs. Liquid Viscosity for 1 ½ (38 mm) Meter R egion Non-Operating R D = 12 R D = 2 Non Linear Region R D = 5 Non-Linear Region R D = 5 Accuracy = 2% of Rate Accuracy = 2% of Rate 2. 12.5 25 37.5 5 ELECTRONICS Accuracy.1% of full scale for both the two-wire transmitter and the signal converter. Includes the combined effects of conformity, hysteresis, deadband, and repeatability errors. Supply Voltage Effect Two-Wire Transmitter: None within the transmitter s operating range Signal Converter: Less than.1% per 1 Vac FUNCTIONAL SPECIFICATIONS METER BODY Flowrate Limits The flowrates in Table 2 are for water with a viscosity of 1. cst. For fluids with other viscosities, use the relationships in the minimum flowrate section to determine the minimum flowrate. Table 3 lists the upper range limits (URL) for a 2 ma output; for example, a 1 ½ (38 mm) meter can be calibrated to have a 4-2 ma output for flow ranges from -15 to -5 GPM. 2

TABLE 2 Flowrate Limits TABLE 3 Upper Range Limits Static Pressure Limits Maximum working pressure is equal to the flange ratings. Meters are available with 15 or 3 lb. flanges. Flange ratings are based on ANSI B16.5. K Factor The K factor is the ratio of pulses to gallons of flowing fluid. Nominal K factors are listed in Table 4. K factors will vary slightly from meter to meter. The K factor for a meter is determined by averaging its K factor over the operating range. Actual K factors are supplied for each flowmeter. Figure 5 shows a typical K factor vs. R D curve for a 1 (25 mm) meter. K Factor Pulses/Gallon Flow Units GPM L/S Flow Units GPM L/S Meter Size (IN/mm) K Factor (Pul/Gal) Meter Size (in/mm) ¾ (19) 1 (25) 1 ½ (38) Min Max Min Max Min Max.35.22 2-8 8.55.12-.55 TABLE 4 Nominal K Factors ¾ (19) 133.75.47 5-17 1 (25) 44 FIGURE 5 Typical K Factor vs. R for 1 (25 mm) Meter 17 1.7 Meter Size (in/mm).315-1.7 2..126 ¾ (19) 1 (25) 1 ½ (38) 15-5.95-3.15 1 ½ (38) 1 D Curve 5 3.15 Operating Temperatures Standard: -4 to 176 C (-4 to 35 F) With Optional Cryogenic Sensor: -196 to 176 C (-32 to 35 F) NOTE: Optional Cryogenic Sensor requires use of fourwire signal converter. Pressure Loss Figure 6 is a graph of pressure loss vs. flowrate. These pressures are for water with a density of 62.43 lb.ft. The pressure loss for water with other densities, or other fluids, can be found by using the following equation: P = X 1 Q 2 y P = Pressure loss in PSI or kpa X 1 = Pressure loss coefficient from Table 5 Q y = Flowrate in GPM or l/s = Density at flowing conditions in lb/ft 3 or N/m 3 TABLE 5 Pressure Loss Coefficients Meter Size (IN/mm) ¾ (19) 1 (25) 1 ½ (38) Press. Loss Coef. English 4.93 x 1-3 1.15 x 1-3 1.2 x 1-4 Press. Loss Coef. Metric 5.3 x 1-2 1.129 x 1-2 1.14 x 1-3 Minimum Back Pressure The minimum back pressure required to ensure proper operation of the flowmeter can be found by using the equation below. If the actual downstream pressure is less than the minimum back pressure, flashing may occur. Any condition that contributed to flashing or cavitation should be avoided because faulty signals may occur. P G = (1.5 P) + (1.25) (P V ) (P ATM ) P G = Gauge pressure in PSI or kpa five pipe diameters downstream of flowmeter P = Calculated pressure loss P V = Vapor pressure at line conditions in PSI or kpa absolute P ATM = Atmospheric pressure in PSI or kpa absolute Reynolds Number 3

FIGURE 6 Pressure Loss vs. Flowrate Flowrate (L/S).63.631 6.31 1 PHYSICAL SPECIFICATIONS MATERIALS OF CONSTRUCTION Process Wetted Parts Meter Body: 316 LSS Sensor: 316 L SS with Hastelloy O-Ring: Viton A C Pressure Loss (PSI) 1. 1. ¾ (19.5 mm) 1 (25.4 mm) 1 ½ (38.1 mm) Non-Wetted Parts Meter Body: Cover: 18-8 SS Gasket: Neoprene Two-Wire Transmitter: Cover: Aluminum Gasket: Neoprene Housing: Low Cu Cast Aluminum Signal Converter: Enclosure: Carbon Steel Gasket: Neoprene.1 1. 1. 1 ELECTRONICS Operating Temperature Two-Wire Transmitter: -4 to 85 C (-4 to 185 F) Signal Converter: -3 to 5 C (-22 to 122 F) Output Signal Two-Wire Transmitter: The analog output is 4-2 ma with a maximum load of 15 ohms. Signal Converter: The signal converter provides a pulse and analog output. The pulse has a rise/fall time of 1 µsec with a maximum of 5 µf. The scaled pulse width is 5-7 msec. The analog output is 4-2 ma with a maximum load of 6 ohms. NOTE: This converter must be used with Optional Cryogenic Sensor. Power Requirements Two-Wire Transmitter: Compliance voltage is 1 Vdc. See Figure 7 for operating range. Signal Converter: 12 Vac, +1%, 5-6 Hz, 13 W (max.) FIGURE 7 Load Requirements Weights Meter Body: See Table 6. Meter Size (in/mm) TABLE 6 Meter Body Weights Flange Rating (lb) 15 24 Weight lb (kg) (1.9) ¾ (19) & 1 (25) 3 27 (12.2) Two-Wire Transmitter: 3 lbs. (1.86 kg) Signal Converter: 12 lbs. (5.44 kg) Electrical Connections Meter Body: ½ NPT connection Two-Wire Transmitter: Two ½ NPT conduit connections Signal Converter: Three ½ conduit connections Enclosure Specification Meter Body: NEMA 4/IP 65 Two-Wire Transmitter: NEMA 4/IP 65 Signal Converter: NEMA 4/IP 65 1 ½ (38) 15 56 (25.4) Process Connections Standard 15 or 3 lb. raised face flanges. ratings are based on ANSI B16.5 3 61 (27.7) Flange Load (Ohms) 15 1 5 Operating Range HAZARDOUS AREA CLASSIFICATIONS Model 14MX Flowmeter FM approved for Class I, Division 1, Groups A, B. C & D; Class II, Division 1, Group s E, F & G; and Class III, Division 1 when connected per drawing number 1532-1419 or 1532-142 and installed per manufacturer s instructions. 1 2 3 4 Supply Voltage (Vdc) Max. Load = (V S 1) Volts.2 Amps 4

Model 14 Deflection Sensor Signal Converter FM approved for Class I, Division 2, Groups A, B, C & D; NEMA 4. The Model 14 Converter acts as a barrier for flowmeter equipment locat ed in hazardous locations as follows: Class I, Division 1, Groups A, B, C & D; Class II, Division 1, Groups E, F & G; and Class III, Division 1 when connected per drawing number 1532-1419 and installed per manufacturer s instructions. Model 14 Two-Wire Transmitter (P/N 15973-1) FM approved for Class I, division 1, Groups A, B, C & D; Class II, division 1, Groups E, F & G; and Class III, Division 1 when connected per drawing number 1532-142 and installed per manufacturer s instructions. FM approved without barriers for Class I, Division 2, Groups A, B, C & D; NEMA 4. FLOWMETER SELECTION PROCEDURE Use the following procedure to select the proper flowmeter. Step 1 TABLE 7 Fluid Specifications Fluid: Flowrates (GPM): Max. Min. Normal Temperature ( F): Max. Min. Normal Viscosity (centistokes) @ Normal Temp: Specific Gravity: Pressure (PSIG): Max. Step 4 Determine the minimum measurable flow. By using the performance specifications, calculate the minimum measurable flowrate for the meter body chosen. If a larger flowmeter is needed, try the Model 141 general service flowmeters. Step 5 Verify the remaining specifications. Check the temperature and pressure requirements with the functional specifications. Step 6 Define the model and part numbers required using the catalog model selection guides. The full catalog and the Fluidic Flowmeter section are only available for downloading on our web site, FIGURE 8 Two-Wire Transmitter Step 2 Determine which electronics are best suited for the process. The choices are the two-wire transmitter and the deflection sensor signal converter. The two-wire transmitter is the most economical and provides a 4-2 ma analog signal. If a pulse output or a pulse output and a 4-2 ma signal are required, the deflection sensor signal converter is required. FIGURE 9 Deflection Sensor Signal Converter Step 3 Determine which size meter is required. To do this, compare the maximum flowrate with the values listed in Table 3. The best meter body to use is the smallest one that will handle the maximum flow. For example, a maximum flow of 15 GPM can be handled by a 1 (25 mm) or 1 ½ (38 mm) meter body. However, choosing the 1 (25 mm) meter body will provide the lowest minimum flowrate, which will result in the highest turndown, and is the most economical choice. 5

OSCILLATORY FLOWMETERS Oscillatory Flowmeters utilize specially designed geometric shapes to create an environment selfinduced, sustained oscillations will occur. Oscillating flowmeters are inherently digital devices, that is, the basic measurement they read is a frequency. In a properly executed flowmeter, the frequency of its oscillations is proportional to volumetric flowrate. There are several categories of oscillatory flowmeters, each with a unique shape. Volumetric Flowrate vs. Frequency For any point in the operating region of the flowmeter, the frequency of oscillation will be related to the volumetric flowrate by the following equation: F = KQ F is the frequency of oscillation K is the calibration factor of the meter Q is the volumetric flowrate K Factor It has been found that the K factor of oscillatory meters varies with Reynolds number. Because of this, it is convenient to plot the K factor versus the Reynolds number. If the meter was perfect, it would have a constant K factor at the Reynolds numbers, but this is not the case. All oscillatory meters exhibit a K factor curve that looks similar to Figure 1. exchange flowmeter is similar to the Coanda flowmeter, but differs in the mechanism used to produce oscillations. The geometric design of the momentum exchange meter body produces a continuous, self-induced oscillation at a frequency that is linearly proportional to volumetric flowrate. The fluid oscillations are developed by the fluidic phenomenon of Momentum Exchange (MX). The geometric shape of the meter body creates a main flow of fluid, which passes through the nozzle, and is directed toward one side of the meter body or the other. The force of the jet of fluid will create a flow pulse in a feedback passage. This flow pulse will travel through the feedback passage and exert a force on the main jet. The momentum of the feedback fluid will deflect the main flow in such a manner that it will exert a force on the fluid in the other feedback passage, while the feedback action is repeated and results in a sustained oscillation. The sensor located in the feedback passage detects the fluid pulses, and the sensor signal is conditioned by a signal converter. Figure 11 shows the cross-section of a momentum exchange flowmeter. FIGURE 11 Cross-section of a Momentum Exchange Flowmeter FIGURE 1 K Factor vs. Reynolds Number 11 18 16 PUL/GAL 14 12 1 98 96.1.1 1. 1. GPM/CKS How well the actual meter performs is a function of the design of the meter as well as the influence of the fluid flowing through it. There is a region on the curve the K factor is essentially constant. This is the normal operating region for oscillating flowmeters. In this region, the accuracy is good enough to be stated as a percent of instantaneous flowrate. Momentum Exchange Flowmeters Momentum Exchange flowmeters are based on the fluid phenomenon of momentum exchange. The momentum 6