ANCILLARY STEEL STRUCTURES FOR INDUSTRIAL AND CIVILIAN BUILDINGS. a r c h i t e c t u r e m a d e o f s t e e l STEEL INOX

Similar documents
Steelwork and Security Kiosks

distribution Modular Scaffolding

Steelwork and Security Kiosks

STEEL GRATINGS & STAIR STEPS

DICTATOR Lift Shaft System

Advantages. - They are quick, clean and. sizes, floor types and construction systems mean the mezzanines can be adapted to meet specific client needs.

PERI PD 8 The cost-effective shoring for slab tables and high loads

MILT-Pro. Built-in units and control centres for halls

Ladders and scaffold systems

Effective Date: 14-March Table of Contents

THE EMPEROR PRODUCT SHEET

Appalachian Trail Privy Update Form Version 1.5

For all technical info.

11. Construction processes and materials Power House Maintenance Building Fuel Treatment Building...

FOURTH SCHEDULE. [Subsection 33c(1)] STANDARDS FOR CERTIFICATION OF CONSTRUCTION MATERIAL

MODULAR ACCESS SYSTEMS PRODUCT OVERVIEW

Sub-construction for Wall-mounted Longlight

Standard program overview fire doors

Sub-construction for longlight

Mezzanines. Multiply useful surface area by adding one or more additional floors

AMETank. Field Erected and Shop Built Storage Tanks Engineering Application Software

ACCIDENT INTERVETION SYSTEMS

Advantages. - The wide range of sizes, floor types and construction systems mean the mezzanines can be adapted to meet specific client needs.

Sub-construction for ridgelight

Safety Ladders: Made of Aluminium

MODULAR ACCESS SYSTEMS PRODUCT OVERVIEW

Tender specification KLAUS Multiparking TrendVario 4300

Planning and installation instructions

We store: high. wide. deep. safe. Shelving racks. System C 50 single-tier multi-tier

16. Design of Pipeline Structures.

Solutions in Steel Innovative Technologies for Smart Solutions

SMART FIXING SYSTEMS profiles pro ofilees

built build to FORMWORKS CLIMBING, RETAINING WALLS, SPECIAL

SECTION VIBRATION ISOLATION

ACO Bathroom Drainage Linear shower drains

SMART FIXING SYSTEMS

SECTION ENTRANCE FLOOR GRILLES STAINLESS STEEL GRATING

HIGH PERFORMANCE DOORS. Speed-Guardian High performance / speed doors Diverse models for various industries and applications

storage solutions Averys group PAL RACK The high quality pallet storage system for goods of all sizes and weights.

Sound-absorbing and sound-insulating barriers

INTERNSHIP REPORT GOUTHAM.J

IBC Mounting Systems. System solutions for all application areas

Moduline. Acoustic Enclosure System. Rugged Noise Control Structures Using Acoustically Rated & Field Proven Demountable Components

Doors, Windows, Stairs & Fireplaces Doors Doors Outdoor Entry Outdoor Entry Doors Doors Outdoor Entry Outdoor Entry

Distribution Center 1 + 2

Partitions. 24/7 Security

70S - 132S SUN LOUVRE. Sun Control Systems

Logistics and industry. Consignment sales

COMPETENCY ANALYSIS PROFILE General Carpenter 403A. (All unshaded skill sets must be demonstrated/completed)

mounting systems applications overview

Guardrails. A Safe Workplace

11.0 Commercial Infill

LOADING DOCK SYSTEMS HIGH SPEED DOORS LIFT TABLES DOCK SHELTERS SECTIONAL DOORS COMPL. FOOD INDUSTRY L O A D I N G D O C K S Y S T E M S

SOLUTIONS, AS SOLID AS STEEL

INDUSTRIAL GUARDRAIL SYSTEMS

SENTRY PERMANENT GUARDRAIL SYSTEM

VPL-3200B Residential Vertical Platform Lift Technical Specifications

PROTEKTOR PROFILES FOR EXTERNAL THERMAL INSULATION COMPOSITE SYSTEMS

Project s fiche INOV. Frisomat Case study project's fiche INOV

Telephone or

_spav prefabbricati s.p.a. historical notes

Mezza stow. The high quality mezzanine flooring system.

PROGRAM OVERVIEW WALKING/WORKING SURFACE INDUSTRIAL SAFETY PROGRAM REGULATORY STANDARD: OSHA - 29 CFR

CAR PARKS DURABLE SOLUTIONS FOR CAR PARKS

Non-rigit-PVC. Soft PVC strips

RISK BULLETIN. Walking & Work Surfaces: Floors, Stairs and Elevated Workstations Checklist DATE / / NAME SIGNATURE WALKWAYS YES NO ACTION ASSIGNED

Custom Made OVERHEADDOORS, the quality solution for every façade

SECTION ORNAMENTAL ALUMINUM FENCING

DRY CONSTRUCTION SYSTEMS

Established DOC. NO : SSI / PROFILE Rev-03

Product Guide Specification

Model Safety Program

Racking System. " Racking Solutions to meet all your storage needs "

General technical terms and conditions of TAIM e.v. for. M e t a l c e i l i n g s

MDS TL4 Minimum Deflection Systems

MDS TL5 Minimum Deflection Systems

CIRCULAR LETTER NO REVISED SCOPE OF CLASSIFICATION CODES 5040, 5059 & 5538 EFFECTIVE JULY 1, 2018

Newton Group CANADACAR SYSTEM. Basic Construction of the CANADACAR System. CANADACAR Module Format

ETALLODOMI S.A. Head Office: 12, Kastorias str Athens GREECE. Main Warehouse: 49, Agiou Orous str. GREECE

MEGALITE Medium duty steel panel formwork in imperial sizes

COMP ONENT CATA LO GUE FOR INDUSTRIAL BUILDINGS

SUGGESTED SPECIFICATION SECTION ENTRANCE FLOOR MATS AND FRAMES

LAYHER PROTECT SYSTEM

Cardok Sàrl CP37 CH-1295 Tannay Switzerland Phone:

Flat roof for the loading-optimized elevation (adhesive system)

system 200/205 modular hook-on tiles (concealed grid) SAS International +44 (0)

City of Richmond Zoning Ordinance Page 12-1

HOME & BUSINESS IMPROVEMENTS BE CLEVER... BE SAFE... BROCHURE 2017

Basic Design Considerations for a Laboratory. The Ministry of Health & Family Welfare, under the Drugs & Cosmetics Act, laid down

TELECOMMUNICATION TOWERS & CAMOUFLAGE SOLUTIONS CATALOGUE

Kingspan Day-Lite Klick

C. Concrete Inertia Bases: Drawings showing required concrete steel reinforcing, construction details, and dimensions.

ALGRIP Slip-Resistant Metal Trench and Expansion Joint Covers Custom fabricated, slip-resistant cover solutions for civil construction projects

Locrete Building System: the Technology Handbook

Greenhouse facilities from OTTE

Presentation of prefabricated houses. - Main equipments. - Assembly steps. - Some realisations

MCCARTY ARCHITECTS, P.A. POST OFFICE BOX 440 / 533 WEST MAIN STREET TUPELO, MS / FOR ANSWERS TO QUESTIONS CONTACT: JUSTIN HARRINGTON

Chapter 73. Articles of iron or steel

Sabah Shawkat Cabinet of Structural Engineering 2017

ifix INSTALLATION MANUAL PV flat roof installation system Version

Transcription:

meticon S T E E L S T R U C T U R E S P R O J E C T I O N - P R O D U C T I O N - A S S E M B L Y ANCILLARY STEEL STRUCTURES FOR INDUSTRIAL AND CIVILIAN BUILDINGS STEEL INOX ALUMINIUM 1517 CPD 20130021

i met con

ANCILLARY STEEL STRUCTURES FOR INDUSTRIAL AND CIVILIAN BUILDINGS 3 Draft, design, manufacture and installation of ancillary steel structures for industrial and civilian buildings built-in and technological platforms industrial stairs and railings steel structures of pipe bridges for steel pipes crane runways structure for securing technological objects, ventilation and heating units and wiring awnings and shelters fire and climbing ladders tinsmith and edging profiles auxiliary steel structures for mounting of roof and facade components auxiliary steel structures for mounting openings fillings /windows, doors, gates/ supporting structures for transparent facades other steel products /holders for advertising signs and billboards, fence parts, grilles, gates etc./ STEEL INOX ALUMINIUM

i met con Built-in and technological platforms with industrial stairs and railings From the perspective of efficient use of space in buildings and for the purpose of creating a warehouse, office and service areas, different types of built-in platforms are used. Technological platforms (constructions) are an essential part of supplying technological units that are used in various industries (chemical, metallurgical, mechanical engineering, food processing, etc.). Built-in platform can be designed according to the required parameters /size, the required load, purpose, location, etc./ not only in the new building design, but also in already operational, older building, including including ancillary structures (access stairs, railings, etc.) Horizontal elements and columns of built-in and technological platforms are usually designed and made up of steel cylindrical profiles type IPE, HEA, HEB as well as other profile materials. Steel floor gratings in FeZn version and trapezoidal metal sheets /which doubles as a hidden shuttering/ also in FeZn version combined with concrete grout are used as wear layer.

ANCILLARY STEEL STRUCTURES FOR INDUSTRIAL AND CIVILIAN BUILDINGS 5 Industrial stairs and railings Industrial stairs and railings can be supplied as part of the built-in and technology platforms. Type and layout of steel stairways and railings is consulted with customer and the general designer. When designing stair steps we choose alternative to steel floor gratings (grating) in the FeZn version or metal sheet combined with concrete grout, tile or wooden stair steps (used mainly in the spiral staircase). The staircases are standardly delivered with railings that can be made from steel closed profiles with circular or rectangular crosssection and other profile materials. For aesthetic reasons, stainless steel railings are widely used in administrative or civilian buildings.

i met con Crane runways Crane runways are mounted on the crane runway brackets of buildings column. Brackets are firmly attached to the supporting column of the building. The type and size of crane runway depends on the type, crane capacity and modular distance of columns or brackets. When designing object with a crane the most significant indicator is the lift height or hook of the crane, which determines the total height of the object and the location of crane runway. Part of every crane runway is also a rail, which is mostly designed and made of solid panel profile of a square cross-section. The size and shape of the rail is also dependent on the type and capacity of the crane. Rail is connection to the actual profile of crane runway in two ways namely fixed and non dismountable way /welding/ or dismountable way /screw connection/. Constructions for securing technological objects, ventilation and heating units, pipelines and wiring They can be used in existing buildings as well as new buildings. Proposals are based on dimensions, weight, location and possible method of attachment to the original construction of the building. All these parameters determine and influence the size and appearance of auxiliary construction.

ANCILLARY STEEL STRUCTURES FOR INDUSTRIAL AND CIVILIAN BUILDINGS 7 Awnings and shelters Awnings and shelters are not only aesthetic but also functional, providing shade covering and weather protection. They can be mounted also above entrances (gates, doors), as well as in the walls without entrances, which serve as shelters to create covered areas for example for the purpose of storing material. The material used is the open cross-section rolled profiles (U, UPE, IPE etc.) as well as a closed circular and rectangular cross-section and other profile materials. Polycarbonate sheets of various thicknesses and trapezoidal sheets are used as roofing material. Method of anchoring to the building is chosen according to the type of the original building and can be straight into the construction or the wall of a building or self supporting with individual columns. Fire and climbing ladders Essential part of every industrial and civil building in terms of security and fire protection are fire or simple climbing ladders. Number and their location is based on the design and corresponds to the relevant norms and standards. Design and production of the desired types of ladders is consistent with the project documentation with regard to their location, method of attachment and building height in compliance with the required standards and existing norms.

i met con Tinsmith and edging and curved profiles and components Edging components are produced in tandem press-brake with a total length of 2 x 3000 m (max. length of edging component is 6000 mm) with a maximum thickness of edging component 10.00 mm. Material for the production of profiles and components is sheet in FeZn version, varnished metal sheet or steel sheet without surface treatment. Edging profiles and tinsmith components are used in the construction sector (as auxiliary structures for roof and facade systems, fillers for windows, doors and gates, transparent facades etc.) as well as semi-finished products in the production of complex engineering units. Auxiliary steel structures for roof and facade components They can be used in existing buildings as well as new buildings, where the building supporting structure (skeleton) is formed by steel or reinforced concrete construction. They can be made out of open cross-section rolled profiles (U, UPE, UE) and a closed rectangular cross-sectional profile and other profile materials such as cold rolled economic profiles in FeZn finish. Design of auxiliary steel structures (type, size, spacing of profiles) depends on the static calculation, the required fire resistance and so on. Auxiliary steel structures are suitable structures for roof and facade components: roof and facade sandwich panels different types of stacked sheets roof and facade trapezoidal sheets different types of facade panels and systems

ANCILLARY STEEL STRUCTURES FOR INDUSTRIAL AND CIVILIAN BUILDINGS 9 Auxiliary steel structures for mounting openings fillings /windows, doors, gates/ They can be used in existing buildings as well as new buildings, where the building supporting structure (skeleton) is formed by steel or reinforced concrete construction. They can be made out of open cross-section rolled profiles (U, UPE, UE) and a closed rectangular cross-sectional profile and other profile materials such as cold rolled economic profiles in FeZn finish. Design of auxiliary steel structures (type, size, spacing of profiles) depends on the static calculation, the required fire resistance and so on. Auxiliary steel structures are suitable structures for mounting openings fillings: plastic, aluminum and steel windows and doors sectional and rolling industrial gates sliding and hinged steel gates skylights

i met con Supporting structures for transparent facades They are made of rolled profiles of closed rectangular crosssection and other materials. Their size, wall thickness and shape are given by static calculation. Profiles for supporting structure are normally produced in the widths of 50 or 60 mm (depending on the technical solution of buildings, also in other widths) and various building depths. Profiles can be connected by connectors or welding, and for reasons of greater stability, welded structures are preferred. It is then possible to fix (anchor) system facade elements with filling on the supporting structure.

ANCILLARY STEEL STRUCTURES FOR INDUSTRIAL AND CIVILIAN BUILDINGS 11 Other steel products holders for advertising signs and objects billboards fences, grilles, gates, railings traffic sign gantries construction of noise barriers bridging walkways racks stainless steel constructions products from perforated metal sheets and expanded metal

meticon Registered office: METICON, a.s. Osloboditeľov 4 976 67 Závadka nad Hronom SLOVAKIA Tel: +421 48 619 89 72 Fax: +421 48 619 89 71 Mobile: +421 905 494 700 E-mail: info@meticon.eu www.meticon.eu