MAJESTIC FLOOR MEMBRANE PRODUCT GUIDE

Similar documents
ARDEX UNDERTILE INTERNAL LIQUID WATERPROOFING MEMBRANES. Product. Scope. Building Regulations. Appraisal No. 472 [2017]

RIW SHEETSEAL GR BENEFITS APPLICATIONS APPLIED TO

Schluter -KERDI-DRAIN

Product. Scope MAPEGUM WPS, MAPELASTIC, MAPELASTIC SMART, MAPELASTIC TURBO AND MAPELASTIC AQUADEFENSE WET AREA MEMBRANES. Appraisal No.

ALLNEX DAMP PROOF AND TANKING MEMBRANES. Product. Scope. Appraisal No. 805 [2013] Appraisal No. 805 (2013) Amended 26 January 2018.

Roofing. Carrier Membrane SA. Self-adhesive Carrier Membrane. Product Description. Tests. Product Data. Form. Storage

Gas Protection System Components

AQUABLOK INTERIOR WATERPROOFING MEMBRANES. Product. Scope. Appraisal No. 724 [2017]

Construction. S-Vap 5000E SA Self-adhesive Vapour Barrier. Product Description

SIKALASTIC-152 EXTERIOR WATERPROOFING MEMBRANE. Product. Scope. Appraisal No. 811 [2013] Appraisal No. 811 (2013) Amended 28 August 2017

CHAPTER 10: Finishes CONTENTS 10.1 PLASTERWORK 10.2 SECOND AND THIRD FIX FINISHES. Chapter 10

HYDRATHANE INTERIOR WATERPROOFING MEMBRANE. Product. Scope. Building Regulations. Appraisal No. 959 [2017] Appraisal No. 959 (2017) BRANZ Appraisals

E. Section Polymer Modified Cement Waterproofing. K. Section Sub drainage: Foundation perimeter drainage.

Construction. SikaMembran system Vapour control/waterproofing sheet system for ventilated curtain walling

SECTION CERAMIC TILE. B. Ceramic tile wall finishes including standard and custom designs.

PRODUCT SELECTION GUIDE

Start the installation at one corner of the building. Unroll the first sheet of MiraPLY-H square/parallel to the building wall, starting at one corner

Colphene BSW Training and Application Guide. Colphene BSW Waterproofing Membrane. 1. Prepare substrate

PITCHED ROOF SOLUTIONS

GypLyner. GypLyner. Metal framed wall lining system. All our systems are covered by SpecSure when using genuine Gyproc and Isover products.

System Recommendation SR0618

SECTION mil thickness COLD FLUID-APPLIED WATERPROOFING

Product Data Sheet Waterproofing Membrane for Ponds and Water Features Description Uses Suitable Surfaces Additional Uses Specification

WATERPROOFING CONSTRUCTION JOINTS

INSTALLATION METHOD STATEMENT

Waterproofing Systems for Wet areas

Construction. SikaProof A. Fully bonded FPO sheet waterproofing membrane system for basement and other below ground structures. Product Description

Eco friendly manufacture which is kind to the environment. Kind to the Environment. High Compressive Strength. Lightweight & Easy to Handle

J41 Reinforced bitumen membrane roof coverings

SECTION D Masonry Wall Systems. Contents. Introduction. Design Considerations. Installation. Components. System Specifications.

Crystoflex Max comprising of a liquid component of selected polymers and a powder component of selected cements, fillers and aggregates.

Wet Room Floor Solutions

Union County Vocational - Technical Schools Scotch Plains, New Jersey

RENEW ELASTOMERIC ACRYLIC COATING (PAINT GRADE) MANUFACTURERS SPECIFICATION / SECTION

SMARTPLY PROPASSIV - AIRTIGHT OSB

TILE TILE

VISQUEEN RADON MEMBRANE SYSTEM

IT S WHAT S UNDERNEATH THAT COUNTS. MARMOX Board PRO / ULTRA Tile Backer Boards MEMBER OF CMB GROUP

Vario XtraSafe. Airtightness and moisture management system.

SECTION SHEET MEMBRANE WATERPROOFING AND CRACK ISOLATION

Acceptable Floor Substrates: Concrete, cured mortar bed, plywood, and backer board.

Thermal Laminate Board.

Waterproofing Systems

Tidy tiles Walls, floors, stairs and tiles on tiles Building materials of brand-name quality for your home Nur im

Visqueen Ultimate HC BLOK

84 Lapping & Jointing 86 Service Pipe Penetrations 87 Sealing to Cavity Wall Constructions 88 Protecting Membranes System Components.

A100 SHOWERPROOF NON-SLIP CERAMIC TILE ADHESIVE

DURABASE CI 1/5. Underlay mats for decoupling and waterproofing tiled flooring APPLICATIONS AND FUNCTION.

Section Pre-Applied Sheet Membrane Waterproofing

Levelling compounds.... plane, smooth surfaces with Alfix

Sarnavap 1000E is an unsupported vapour control layer based on PE-LD (Low Density Polyethylen).

Products for the Tiling Industry

J41 Reinforced bitumen membrane roof coverings

Fixing elements for concept xps panels. concept xps. u./pallet

Construction. Fully bonded FPO sheet membrane waterproofing system for basement and other below ground structures. Product Description

SIKA EGYPT ENG. HOSSAM ABD ELMAGIED SPECIFICATION DEPARTMENT DEC. 2016

NEGATIVE SIDE WATERPROOFING SYSTEMS FOR MASONRY AND CONCRETE

SECTION COLD APPLIED RUBBER MODIFIED ASPHALT WATERPROOFING

SECTION SELF-ADHERING SHEET WATERPROOFING

TEKTON Flashings and TEKTON Construction Tape

FreeStyle Linear Drain with Full Mortar Bed Adapter Kit

ACOUSTIC INSULATION UNDER SCREED made from recycled rubber granules

Outline NBS Specification. Protec System to PVC Single Ply (Waterproofing Only)

Majvest. Tips and Tricks. 3-layer, tear-proof and flexible can be laid easily, quickly and securely. 3 m wide with cutting and bonding aid saves time

Over 20 years experience of high quality commercial hygienic wall and ceiling cladding supplies. Quality you can trust

Extreme Sealing Tape

A. The work of this section includes, but is not limited to, the following:

Detailing guide for senior living facilities

Air and Vapor Barrier 3015

WATERPROOFING TAMKOWATERPROOFING.COM

Mapei systems for radiating floor heating with high thermal efficiency

Waterproofing construction Joints

TECHNICAL BULLETIN TB147 THE INSTALLATION OF ARDEX DS40 SOUND REDUCTION MATTING IN INTERNAL INSTALLATIONS

NURAPLY 3PT TECHNICAL DATA SHEET

DURABASE. Systems for decoupling, sealing, drainage, sound and heat insulation. Systematic underlays. WP page 4/5. CI++ page 2/3. DD page 6.

European Technical Assessment ETA-09/0156 of 18/12/2015

STANDARD INSTALLATION GUIDELINES

SECTION 07530CP EPDM MEMBRANE ROOFING

Henry Self-Adhering Roofing Underlayments. self-adhering. roofing underlayments DESIGNED FOR: Shingles. Tile. Metal. Slate

METHOD STATEMENT 001 CONCRETE BALCONY WATERPROOFING FOR DIRECT FIXED TILES

INSTALLATION INSTRUCTIONS

European Technical Assessment ETA-11/0518 of 19/08/2015

A. Source Limitations: Obtain each type of building insulation through one source.

SECTION TILING

Balconies Information. How to waterproof and reduce efflorescence

SECTION SHEET MEMBRANE SOUND REDUCTION, CRACK ISOLATION / JOINT BRIDGING, AND WATERPROOFING

Installation Manual. ThermMAT ThermCABLE FME. Technical Helpline:

Mapesonic CR Mapesilent

ARCHITECTURAL GUIDE SPECIFICATIONS - DESCRIPTIVE

Installation Guide and Safety Manual Resilient Sound Isolation Clips (SIC Clips)

Plasterboard accessories - Products

The extra strong, extra durable, sound resistant system that you can direct fix to

Most products will act differently when installed over an UFH system than when installed on a standard unheated subfloor.

Multithane UV is designed to waterproof most applications within the building and construction industry including:

TILING SPECIFICATIONS

AQUATITE. Also designed as: Crack/gap filler for masonry and unglazed ceramics Sealants against leaks Repairer for roof cracks and gutters

Flooring Systems.

Multi-layer Insulation Blanket for Walls

DRYPROOF UNDER TILE EXTERNAL WATERPROOFING MEMBRANE. Product. Scope. Appraisal No. 887 [2015] Appraisal No. 887 (2015) Amended 17 September 2015

Installation Guide Acrylic Bath W/O Apron

Transcription:

PRODUCT GUIDE p13 p7 p9

PRODUCT DETAIL The Majestic Floor Membrane is a self-adhesive waterproof membrane designed for use prior to the application of ceramic tiles and natural stone onto timber and solid floors in wetrooms and other critical areas. Majestic Floor Membrane comprises a self-adhesive cold applied waterproof membrane which consists of a thick butyl waterproof layer incorporating a fleece on one side. Majestic Floor Membrane is quick and easy to apply, providing a consistent waterproof layer that is guaranteed not to leak. KEY FEATURES 10 year guarantee Suitable for timber and solid floors Self-adhesive - quick and easy to apply Ready to tile immediately Ideal for fast track construction Supplied as a kit Factory controlled thickness p1

KIT CONTENTS PRODUCT DETAILS Majestic Floor Membrane A self-adhesive waterproof membrane consisting of a 2mm thick butyl layer, incorporating a fleece on one side. Width 1 Metre. Reinforcing Tape A 1mm thick self-adhesive tape for reinforcing all wall and floor junctions, butt joints and other detail work in the membrane. Width 125mm. Primer A quick drying acrylic primer for use prior to the application of the membrane and Reinforcing Tape. Jointing Compound A high quality polymer based sealant for use at all butt joints, pipe entries, wall and floor junctions. Putty A non-setting self-supporting putty for filling small gaps or voids around pipe entries etc. MEMBRANE KIT IMAGE DESCRIPTION 5m² Membrane kit Kit contains 5m x 1m roll of Membrane, 10m Reinforcing Tape, 500ml Primer, 310ml Jointing compound, 500g Putty 10m² Membrane kit Kit contains 10m x 1m roll of Membrane, 15m Reinforcing Tape, 1Ltr Primer, 310ml Jointing compound, 500g Putty PRE-FORMED CORNERS Pre-Formed Corners Designed to simplify the installation of the membrane. Manufactured from tough but flexible polyethylene, the corner unit is placed into a corner prior to the installation of Reinforcing Tape at wall/floor junctions. PRE-FORMED CORNERS For timber floors we recommend that the Majestic Floor Membrane is applied to the entire wetroom floor. For solid floors we recommend that the Majestic Floor Membrane is applied to the shower area plus an additional one metre in either direction. Majestic Wall Membrane should then be applied to the walls of the shower area and overlapped onto the Reinforcing Tape. Care should be taken to ensure the temperature is at least 10 C. Conditioning of the membrane in a warm area prior to use will enhance its adhesion properties during application. REINFORCING TAPE Reinforcing Tape 125mm wide self-adhesive waterproofing tape for sealing critical detail such as wall junctions, soap recesses, pipe boxing and other such areas prior to tiling. REINFORCING TAPE p2 p3

IN DETAIL TYPICAL WATERPROOFING DETAIL Majestic Floor Membrane is a unique, pre-formed flexible self-adhesive waterproof membrane. It is ideal for use on substrates, such as timber, masonry, concrete, plasterboards, gypsum and existing ceramic or natural stones. Once applied, Majestic Floor Membrane is ready to tile immediately. Majestic Floor Membrane is cold applied, consisting of a 1mm thick butyl waterproof layer, incorporating a fleece on one side. It has been developed for use prior to the fixing of ceramic tiles and natural stone, applied using a flexible rapid-set tile adhesive, which keys to the fabric. As the adhesive dries it forms a strong permanent bond to the membrane. Majestic Floor Membrane and ancillary products should be stored in the original cartons, upright and out of direct sunlight, below 35 C. Protect from frost. Cartons should not be over stacked. The membrane may be tiled onto immediately, however it will take 48 hours to achieve it's full bond strength. PERFORMANCE & COMPOSITION Membrane thickness Joint Tape thickness Tensile Strength (ASTM D3759) Elongation at break (ASTM D3579) Peel Adhesion at 180 angle (ASTM 3330) 1mm 1mm 140N /5cm - (Cross Direction) 120% - (Cross Direction) 11N/mm TIMBER FLOORS (SMALL EN-SUITE) LARGE TIMBER FLOORS AND SOLID FLOORS Majestic Floor Membrane to be applied, in accordance entire floor area. Additional Reinforcing Tape to be applied to all wall to wall junctions, soap recesses etc, within the shower area. Majestic Wall Membrane to be applied, in accordance walls within the shower area finishing a minimum of 2 metres high and overlapping onto the floor Membrane. All pipe penetrations to be sealed with Jointing Compound. For steam rooms, Majestic Wall Membrane should be applied full height to all walls. Majestic Floor Membrane to be applied, in accordance floor area finishing a minimum of 1 metre outside the shower area in all directions. Additional Reinforcing Tape to be applied to all wall to wall junctions, soap recesses etc, within the shower area. Majestic Wall Membrane to be applied, in accordance walls within the shower area finishing a minimum of 2 metres high and overlapping onto the floor Membrane. All pipe penetrations to be sealed with Jointing Compound. For steam rooms, Majestic Wall Membrane should be applied full height to all walls. RIW TILESAFE 4.1 p4 p5

Majestic Shower Company Ltd Harlow Office Two North Place Edinburgh Way Harlow, Essex CM20 2SL Telephone: +44 (0)844 800 1500 Facsimile: +44 (0)1279 635074 Barnsley Office Unit C, Shortwood Court Shortwood Business Park Barnsley, South Yorkshire S74 9NW Telephone: +44 (0)1226 360300 Facsimile: +44 (0)1226 749900 info@majesticshowers.com