RESEARCH IN PROGRESS: FATIGUE OF CFRP COMPOSITES

Similar documents
Ultimate strength prediction for reinforced concrete slabs externally strengthened by fiber reinforced polymer (FRP)

BEHAVIOR OF INFILL MASONRY WALLS STRENGTHENED WITH FRP MATERIALS

AN INNOVATIVE DUCTILE COMPOSITE FABRIC FOR STRENGTHENING CONCRETE STRUCTURES. Abstract

Performance of NSM FRP strengthened concrete slabs at low temperatures

Flexural Behavior of RC T- Section Beams Strengthened with Different Configurations of CFRP Laminates

STRENGTHENING OF UNBONDED POST-TENSIONED CONCRETE SLABS USING EXTERNAL FRP COMPOSITES

Deflection Assessment of an FRP-Reinforced Concrete Bridge. By Danielle K. Stone, Andrea Prota, and Antonio Nanni

Structural behavior of eccentrically loaded FRP confined square RC columns

INNOVATIVE HYBRID WEARING SURFACES FOR FRP BRIDGE DECKS

STRUCTURAL CHARACTERISTICS OF CONCRETE-FILLED GLASS FIBER REINFORCED COMPOSITE PILES. Abstract

EXPERIMENTAL STUDY ON DOUBLE LAP JOINTS COMPOSED OF HYBRID CFRP/GFRP LAMINATE

BEHAVIOR OF FRP SANDWICH PANELS FOR TRANSPORTATION INFRASTRUCTURE

STRENGTHENING STEEL-CONCRETE COMPOSITE BRIDGES WITH HIGH MODULUS CARBON FIBER REINFORCED POLYMER (CFRP) LAMINATES

DETERMINATION OF ULTIMATE FLEXTURAL CAPACITY OF STRENGTHENED BEAMS WITH STEEL PLATES AND GFRP INTRODUCTION

Fatigue and Overloading Behavior of Steel Concrete Composite Flexural Members Strengthened with High Modulus CFRP Materials

Behavior of Concrete-Filled FRP Tubes Under Bending, Axial Loads, and Combined Loading. Amir Fam, Bart Flisak and Sami Rizkalla

Repair of Earthquake-Damaged RC Columns with FRP Wraps

Experimental Study of Reinforced Concrete (RC) Beams Strengthened by Carbon Fiber Reinforced Polymer (CFRP): Effect of Beam Size and Length of CFRP.

AFFECT OF ENVIRONMENTAL CONDITIONS DURING INSTALLATION PROCESS ON BOND STRENGTH BETWEEN CFRP LAMINATE AND CONCRETE SUBSTRATE

Assessment of Long-Time Behavior for Bridge Girders Retrofitted with Fiber Reinforced Polymer

DISTORTION-INDUCED FATIGUE CRACKING AT WEB-GAP OF WELDED I-BEAMS

FATIGUE TESTS OF HYBRID PLATE GIRDERS UNDER CO:N'fBINED MOMENT A NO SHEAR. M. Natarajan. and. A. A. Toprac

Seismic Retrofit Of RC Columns With Inadequate Lap-Splice Length By External Post-Tensioned High-Strength Strips

Strengthening of Reinforced Concrete Beams using Near-Surface Mounted FRP Mohamed Husain 1, Khaled Fawzy 2, and Mahmoud Nasr 3

The American Institute

FLEXURAL BEHAVIOR OF RC BEAMS REINFORCED WITH NSM AFRP RODS

Strengthening of hollow core precast slabs using FRP composite materials procedure, testing and rating

LATERAL LOAD BEHAVIOR OF UNBONDED POST-TENSIONED HYBRID COUPLED WALLS. Qiang SHEN Graduate Research Assistant. Yahya C. KURAMA Assistant Professor

SMU 2113 ENGINEERING SCIENCE. PART 1 Introduction to Mechanics of Materials and Structures

Appendix D.2. Redundancy Analysis of Prestressed Box Girder Superstructures under Vertical Loads

THE EFFECT OF FATIGUE LOADING ON BOND STRENGTH OF CFRP BONDED STEEL PLATE JOINTS

CFRP STRENGTHENING OF CONCRETE BRIDGES WITH CURVED SOFFITS

Bond Characteristics of GFRP Sheet on Strengthened Concrete Beams due to Flexural Loading

MECHANICAL CHARACTERIZATION OF SANDWICH STRUCTURE COMPRISED OF GLASS FIBER REINFORCED CORE: PART 1

Chapter 2: Strain. Chapter 3: Torsion. Chapter 4: Shear and Moment Diagram

AXIAL TESTING OF CONCRETE COLUMNS CONFINED WITH CARBON FRP: EFFECT OF FIBER ORIENTATION. Abstract

Upgrading the shear strength of non-ductile reinforced concrete frame connections using FRP overlay systems

THE DESIGN OF EXTERNALLY BONDED REINFORCEMENT (EBR) FOR REINFORCED CONCRETE STRUCTURES BY MEANS OF FIBRE REINFORCED POLYMERS (FRP)

LOAD-BEARING PRECAST CONCRETE SANDWICH WALL PANELS WITH BASALT-FRP REINFORCEMENT AND TIES

Vierendeel Steel Truss / Composite Skin Hull Test

The cracking behaviour of reinforced concrete beams under static and dynamic loading

Carder 1. FABRICATION AND CYCLIC LOADING OF SUPER-ELASTIC SHAPE MEMORY ALLOY REINFORCED POLYMER Rachel Carder

NEW HYBRID GLULAM BEAM REINFORCED WITH CFRP AND ULTRA-HIGH-PERFORMANCE CONCRETE

INNOVATIVE FIBRE REINFORCED BRIDGE DECK MODULES ABSTRACT

Determination of through thickness properties for Composite thick laminate S.Vali-shariatpanahi * * Stress Engineer/Durability group leader -Airbus

DIAPHRAGM BEHAVIOR OF DECONSTRUCTABLE COMPOSITE FLOOR SYSTEMS

Tensile/Tension Test Advanced Topics

Structural Behaviour of Sandwich Panels Constructed of Foam Cores and Flax FRP Facings

R. Prokopec, K. Humer, H. Fillunger, R. K. Maix, and H. W. Weber

STRENGTH AND DUCTILITY OF STEEL BEAMS WITH FLANGE HOLES

MACHINES DESIGN SSC-JE STAFF SELECTION COMMISSION MECHANICAL ENGINEERING STUDY MATERIAL MACHINES DESIGN

SHEAR PERFORMANCE OF RC MEMBERS STRENGTHENED WITH EXTERNALLY BONDED FRP WRAPS

Sabah Shawkat Cabinet of Structural Engineering 2017

Seismic Behavior of Concrete Columns Confined with Steel and Fiber-Reinforced Polymers

Numerical Modeling of Reinforced Concrete Beams Strengthened by NSM-CFRP Technique

A PRODUCT FROM KANTAFLEX (INDIA) PVT LIMITED

Journal of Asian Scientific Research EVALUATION OF RECTANGULAR CONCRETE-FILLED STEEL-HOLLOW SECTION BEAM-COLUMNS

with Fillers Department of Civil Engineering, National Taipei University of Technology, Taiwan, R.O.C

Tests on FRP-Concrete Bond Behaviour in the presence of Steel

Nonlinear Redundancy Analysis of Truss Bridges

Metallic Structures. Zhao. Xiao-Ling. FRP-Strengthened (CJ*; CRC Press. Taylor & Francis Croup. Taylor & Francis Croup, an informa business

FINAL REPORT. Prepared by

Nonlinear Finite Element Modeling & Simulation

EXPERIMENTAL RESULTS

Ductility of Welded Steel Column to Cap Beam Connections Phase 2

The strength of a material depends on its ability to sustain a load without undue deformation or failure.

GFRP retrofitted RC frames with columns subjected to high axial stresses

Finite Element Analysis of RC Beams Strengthened with FRP Sheets under Bending

EXPERIMENTAL ANALYSIS ON THE SHEAR BEHAVIOUR OF RC BEAMS STRENGTHENED WITH GFRP SHEETS

FUNDAMENTAL CHARACTERISTICS OF HIGH MODULUS CFRP MATERIALS FOR STRENGTHENING OF STEEL-CONCRETE COMPOSITE BEAMS

Table of content of printouts:

FE MODELING OF CFRP STRENGTHENED CONCRETE BEAM EXPOSED TO CYCLIC TEMPERATURE, HUMIDITY AND SUSTAINED LOADING

CRACKING BEHAVIOR AND CRACK WIDTH PREDICTIONS OF CONCRETE BEAMS PRESTRESSED WITH BONDED FRP TENDONS

SEISMIC UPGRADING OF EXISTING RC ORDINARY MOMENT RESISTING FRAMES USING FRPS

Effect of Bar-cutoff and Bent-point Locations on Debonding Loads in RC Beams Strengthened with CFRP Plates

DESIGN GUIDELINES Partial safety factors for strengthening of metallic structures. Dr. Stuart Moy University of Southampton

Experimental investigation of the use of CFRP grid for shear strengthening of RC beams

Strengthening steel bridges with new high modulus CFRP materials

Proposed Modifications to the LRFD Design of U-Beam Bearings

RESILIENT INFRASTRUCTURE June 1 4, 2016

The use of 0.5 and 0.6 in. (13 and 15 mm) diameter

DEVELOPMENT OF DUCTILE-HYBRID COMPOSITES (DHC) BY THE BRAIDTRUSION PROCESS

Carbon-fiber Reinforced Concrete with Short Aramid-fiber Interfacial Toughening

DESIGN GUIDELINES FOR BRIDGE DECK SLABS REINFORCED by CFRP and GFRP

Structural Upgrade of Reinforced Concrete Column-Tie Beam Assembly using FRP Composites

Initial Tests of Kevlar Prestressed Timber Beams

RESEARCH ON SEISMIC RETROFIT OF EARTHQUAKE-DAMAGED AND SEISMIC-DEFICIENT STRUCTURES USING FIBRE-REINFORCED POLYMER (FRP) TECHNOLOGY

Nonlinear Finite Element Analysis of Composite Cantilever Beam with External Prestressing

Composite Solutions for the Automotive Industry

Expanding the Performance Envelope for Long Fiber Thermoplastic Composites with Unidirectional Tape Inserts

GFRP HOLLOW-CORE REBARS FOR CONCRETE BEAMS

REINFORCING LARGE DIAMETER ELBOWS USING COMPOSITE MATERIALS SUBJECTED TO EXTREME BENDING AND INTERNAL PRESSURE LOADING

Louisiana Transportation Research Center

SOLUTION IMPREGNATION OF NATURAL FIBRES/ABS MATRIX COMPOSITES

Experimental Behavior of Concrete Cylinders Confined with CFRP Composites

Reinforced Concrete Design. A Fundamental Approach - Fifth Edition

CHAPTER 23 PILES TABLE OF CONTENTS TABLE OF CONTENTS. 23.TOC Table of Contents... 30Jan Introduction... 30Jan2018

STRENGTHENING OF TUNNEL SUPPORTS USING CARBON FIBRE COMPOSITES

OLD KEYS BRIDGE REPAIRS Negative Moment Strengthening of the Rockland Channel Bridge Florida

Behavior and Strength of Slab-Edge Beam-Column Connections under Shear Force and Moment

Transcription:

RESEARCH IN PROGRESS: FATIGUE OF CFRP COMPOSITES Cornelia E. Demers, Ph.D. 1, Amir Abdelgadir 2 1 Department of Civil Engineering and Engineering Mechanics, The University of Arizona Tucson, Arizona, 85721, USA 2 Department of Civil Engineering and Engineering Mechanics, The University of Arizona Tucson, Arizona, 85721, USA SUMMARY: For bridge structures, fatigue is an important load condition. The fatigue life diagram for unidirectional CFRP composites is shown. This diagram represents the 95% lower confidence level and is useful in conservatively estimating the fatigue life of the CFRP composites when used as a sole structural material. For hybrid systems, understanding the fatigue behavior of the individual materials is relevant to understanding system behavior. The first test in a series on flexural fatigue testing of steel beams reinforced with CFRP composites adhesively bonded to the tension flange is discussed. The work in progress is presented including laboratory test results obtained to-date. This project demonstrates the positive strengthening effect of CFRP composites to steel bridge girders. KEYWORDS: CFRP composite, steel, fatigue, hybrid system INTRODUCTION In the interest of pursuing the rehabilitation/strengthening alternative for bridge structures in lieu of a larger bridge replacement program, FRP composites are viable alternative construction materials. For bridge structures subject to cyclic loading, fatigue is an important limit state in design. Traditionally, fatigue strength of a material is represented by stress category of design detail and a corresponding S-N curve (fatigue life diagram). For steel, fatigue strength is well documented in various codes such as AISC-LRFD Manual of Steel Construction or AASHTO Bridge Design Manual. For unidirectional CFRP composites in bridge application, no usable document summarizing the fatigue strength was available. The primary author therefore undertook an evaluation of existing fatigue data which had been generated in the context of aerospace, marine, and mechanical applications, for a wide range of composite material systems under various loading conditions. A review of that existing data revealed select data as suitable to bridge infrastructure application [1, 2]. A summary of that select data is a preliminary step in defining the fatigue life diagram of unidirectional CFRP composites for stress Category A detail in T-T axial fatigue with test frequency 20 Hz or less, without environmental concerns. Understanding the individual fatigue behavior of materials is relevant to understanding the fatigue behavior of a system comprising those individual

materials. A research program at the University of Arizona is currently ongoing to understand the fatigue behavior of a steel beam reinforced with CFRP composite. The test results of a hybrid beam is presented herein. The objective of the test was to observe the fatigue category of detail at the CFRP composite ends. Axial Fatigue of Unidirectional CFRP Composite Frequency of fatigue load effects internal heating of the composite, and therefore, fatigue life. The review of laboratory data suggested limiting the test frequency of fatigue load to 20 Hz with observed specimen surface heating 10 o C, or less. This controlled selecting from the aerospace, marine, and automobile industry suitable data to represent bridge application [1, 2]. The data represented a stress Category A detail in tension-tension axial fatigue. Graphing the data in Figure 1 shows a distinct data band to which a lower bound confidence level is established [1]. This lower bound represents a fatigue life diagram from which unidirectional CFRP composite fatigue strength is estimated. The S-N curve and the stress Category A detail define the tension-tension axial fatigue strength of unidirectional CFRP composite. The data is inconclusive of a fatigue limit. Figure 1. Unidirectional CFRP Composite Fatigue Life Diagram

HYBRID SYSTEM OF STEEL BEAM REINFORCED WITH CFRP COMPOSITE Hybrid System The material properties for each of the components comprising the system are given in Table 1 [3]. Monotonic testing of one layer of CFRP/epoxy composite (15 coupons each sized 254 x 25.4 x 1.5 mm) provided an ultimate tensile strength of 533.5 Mpa and an elastic modulus of 56.7 Gpa. As for the S5 x 10 A36 steel beam, two sections 914.4 mm long were groove weld connected to form one 1.83 m long beam. The groove welds were ground flush on the outer surface of both flanges (but not the inner flange surfaces or web). One layer of CFRP composite was applied (wet lay-up) to the outer surface of one flange of the S5 x 10 A36 steel beam. The CFRP composite spanned 304.8 mm centered on the steel beam groove weld and within the 508 mm distance between central load points as shown in Figure 2 [3]. The groove weld is considered beam centerline and the strain gages are referenced with respect to the centerline. The CFRP composite strengthened flange was the tension flange under fatigue loading. Table 1. Material Properties Steel Beam Carbon Fiber Epoxy (Resin and Hardener) S5x10 A36 steel Unidirectional T-250 12K Jeffco 9600AT-1 E = 29,000 ksi (200 Gpa) E = 33,000 ksi (227.5 Gpa) Tensile Modulus = 181 ksi (1.25 Gpa) Shear Modulus = 11,000 ksi (75.8 Gpa) Tensile Strength = 530 ksi (3.65 Gpa) Tensile Strength = 6-7.5 ksi (41.4-52.7 Mpa) Elongation = 25 % Elongation = 1.4 % Elongation = 7.65 % Density = 490 lb/ft 3 (7.85 g/cm 3 ) Density = 111 lb/ft 3 (1.76 g/cm 3 ) Bond Strength = > 3.05 ksi (21.13 Mpa) Coefficient of thermal expansion 6.5 x 10-6 in/in/ ο F (11.7 x 10-6 m/m/ C) Axial Coefficient of thermal expansion 0.11 x 10-6 in/in/ ο F (0.2 x 10-6 m/m/ C) Min. Application Temp. 55 ο F (12.8 C) Flexural Fatigue Four point loading defined the one-way flexural fatigue test under load control. With four point loading, the central portion of the hybrid beam was under pure bending. Other factors defining the test included a 1.5 Hz test frequency, an R ratio of 0.1, and a maximum stress of 227.5 Mpa. Stain gages were used including 350-ohm resistance for the CFRP composite and

120-ohm resistance for the steel. The strain gages were placed at various distances within the central load points on both the CFRP composite and steel beam as shown in Figures 3a-3d [3]. Figure 2. Test Set-Up for the Hybrid Beam Figure 3a. Exterior Surface of Steel Tension Flange Showing CFRP Composite and Strain Gage Locations Figure 3b. Cut (A-A) Figure 3c. Cut (B-B) Figure 3d. Cut (C-C)

DISCUSSION The hybrid beam was tested in one-way flexural fatigue with a fatigue maximum stress well below the ultimate tensile strength of the CFRP composite and the yield strength of the steel beam. Also, Figure 1 indicates that for CFRP composite to achieve one million cycle fatigue life in tension-tension axial fatigue, fatigue maximum stress is limited to 50% of ultimate tensile strength. The test fatigue maximum stress of 227.5 Mpa is below the 50% ultimate tensile strength (266.8 Mpa). This presumes that the CFRP composite on the steel tension flange acts primarily in tension (simulates tension-tension axial behavior). Therefore, failure occurs not in the main section of steel beam nor in the composite, but either in the steel flange at the CFRP composite ends or at the «toe» along the tension steel flange groove weld. In essence, the CFRP composite behaves as a cover plate that is adhesion bonded rather than welded (which is used for connecting steel cover plates to steel beam flanges). The method of using adhesion bonding rather than welding to connect the flange strengthening material eliminated the weld heat affected zone in addition to eliminating any welding discontinuities that could become a fatigue crack initiation site. Therefore, the stress concentration in the steel tension flange along the CFRP composite edge and at the composite end is lower than that due to welding. The question arises as to whether the stress concentration with adhesion bonding is significantly lower such as not to cause fatigue cracking. The first step is answering this question was to start with the above described test hybrid beam. During fatigue testing, the strain gages (1, 2, 9, 10) indicated slight rotation (torsion) of the cross-section under loading. This may be attributed to mild misalignment of the steel section and the potential for the loading placed mildly unsymmetrical. The strain gages (3, 7, 8) on tension steel flange located 152.4 mm from centerline showed similar strain over fatigue life. This indicates consistent load carrying capacity in the steel flange at the composite ends over the life of the test. Gages (9,12, 13, 14) located 76.2, 19, 57.1, 101.6 mm from centerline showed similar strain behavior over life of test. This indicated no redistribution of load over life of test. Gage 15 located 12.7 mm from composite end showed significantly lower strain throughout fatigue life. This behavior is expected as the load near the composite end would redistribute out of the composite into the steel flange. From 700,000 cycles on, gage 11 located on the composite at the centerline (over the groove weld) exhibited significantly increasing strain. This localized increase in strain indicated the growth of a fatigue crack in the steel in the vicinity of the gage. This increase in strain also indicates the capacity of the composite was reached (maximum load carrying capacity of composite reached with redistribution of load due to fatigue cracking in steel). At a fatigue life of 1.13 million cycles the test was terminated. The hybrid beam was subsequently subjected to monotonic loading to determine the residual strength. Gage 11 and 12 at centerline and 19.1 mm from centerline exhibited the greatest strain and thus lowest composite modulus of elasticity. Gage 15 exhibited the least strain and thus greatest composite modulus. The remaining gages on the composite exhibited similar behavior of moderate strain and thus similar modulus. The final failure of the hybrid beam was due to out of plane buckling accentuated by a region of fast fracture extending from the fatigue crack. The composite spanning the fatigue crack remained intact (composite did not sever).

After failure, the hybrid beam was examined for fatigue cracking. The CFRP composite was removed. The adhesion bond between composite and steel remained intact during the fatigue life and subsequent residual strength test. In fact, the adhesion surface showed few air bubbles (which were expected due to hand wet-lay-up construction process). The composite resin did show regions of distress (cracking perpendicular to flange stress) during residual strength test. The groove welded tension flange region was removed to expose the fatigue crack. Indeed, a semi-elliptical fatigue crack had formed at the toe of the groove weld on the inner surface of the steel beam tension flange. The semi-elliptical fatigue crack had grown into a throughthickness fatigue crack. Essentially the majority of fatigue life is represented at 1.13 million cycles. Figure 4 shows the hybrid beam test at 1.13 million cycles plotting at Category A detail. However, a fatigue life of 700,000 cycles is relevant with respect to transition from fatigue crack initiation site to fatigue crack and this life indicates at Category B detail. Without the composite, the steel beam with groove weld (not fully ground) is regarded as Category C. 100 Stress Range (ksi) 10 Category A Category B Category C hybrid beam 1 1.00E+05 1.00E+06 1.00E+07 1.00E+08 N Figure 4. Hybrid Beam Fatigue Life versus Category of Fatigue Life. CONCLUSIONS The steel beam with tension flange strengthened with one layer CFRP composite spanning the pure moment region was tested in one-way flexural fatigue and subsequently for residual strength. The adhesion bond between composite and steel tension flange remained intact during the fatigue test (1.13 million cycles) and residual strength test. Although the fatigue test was stopped at 1.13 million cycles, failure would have occurred due to the continued growth of and fast fracture from a fatigue crack which had initiated at the toe of the groove weld on the inner surface of the steel beam tension flange. The CFRP composite remained intact spanning the fatigue crack during fatigue testing and residual strength test. However, the amount of composite was not sufficient to prevent the growth of fatigue crack once initiated from weld discontinuities. The addition of CFRP composite to the steel beam with groove weld increased the anticipated fatigue life from Category C to essentially Category B. No fatigue cracking was observed in the steel tension flange at the ends of the CFRP composite. The stress concentration due to composite end is significantly lower that that due to groove weld

discontinuity. Further testing is currently underway whereby the thickness of CFRP composite varies and the groove weld condition (to force failure) is eliminated. REFERENCES 1. Demers, C.E., «CFRP Composite Fatigue Strength with Reinforcement: (0/90), (0/45/90), Unidirectional», paper in writing, 1999. 2. Demers, C.E., «Fatigue Strength Degradation of E-Glass FRP Composites and Carbon FRP Composites», Construction and Building Materials, Vol. 12, 1998, pp. 311-318. 3. Demers, C.E., Abdelgadir, A., «Flexural Fatigue of a Steel Beam Strengthened with CFRP Composite», paper in writing, 1999. ACKNOWLEDGEMENTS The National Science Foundation is gratefully acknowledged for support of this project.