Customer Responsibilities

Similar documents
Author to add specific customer activities or additional help, information, or guidance for the customer to follow prior to installation.

Markes International Thermal Desorption G8125A, G8126A, G8127A, G8128A, G8131A, G8132A, G8136A, G8133A, MKI-MicroC Site Preparation Checklist

Customer Responsibilities

Gerber M Series Site Requirements

Site Preparation Guide. Stratasys J750 3D Printing System. DOC Rev. D1

Pre-installation Manual CONCEPT 301 D/401 D/501 D

Site Preparation Guide. Objet500/350 3D Printing System. DOC Rev. E

Installation plan. Tumble dryer. PT 8807 EL (Electrically heated) en - US Mat. NR / 02

medixx Series Installation Guidelines medixx 50 medixx 60 medixx 70 Suitable for the following Siemens MRI Systems, or similar models:

SYSTEM 1E LIQUID CHEMICAL STERILANT PROCESSING SYSTEM

MNL, SEL DIMENSIONS, SITE AW PLANNING GUIDE ARTWORK SIZE A SHEET 1 OF 1

! CAUTION: Read and follow these instructions.

RapID Raw Materials Verification System

FT-IR Purge Gas Generators

Gerber CAT UV. Site Requirements, Operating Performance Requirements and Warranty Limitations

Applied Biosystems QuantStudio 12K Flex Real-Time PCR System

3M Intelligent Return Plus and Sorter System SL. Architect/Contractor's Package

Endoscope Reprocessor Specification Installation Instructions

Installation plan. Washer-extractor PW 6107 EL. en - GB M.-Nr / 01

Proudly serving laboratories worldwide since 1979 CALL for Refurbished & Certified Lab Equipment Parker N2-04

Gas Generators. Parker Balston

Pre-installation Manual LightCELL Advanced Laser Machining Center

Versatile Research Heat Exchanger

Perkin Elmer HGA-600/ HGA-700 Graphite Furnaces

Model FDL 115 Safety drying chambers for limited quantities of solvent

Laboklav. Type 55 to 195 Liter. Technical Datasheet. Dampfsterilisatoren Steam sterilizers

ENCORE 2G MEDIUM LABORATORY STERILIZER SPECIFICATION/DATA SHEET

MHWW-09-H-1 Chilled/Hot Water Hi-Wall Fan Coil. Heat / Cool Fan Coil 9,000 BTUH. Rev. 1.3

Installation recommendations. Washer-extractor PW 6080 EL AV/LP. en - GB Mat. no / 01

OxiPRO Q2.0 Microbial Control Technology

Installation Instructions

Facility Requirements Guide Viper Pro SLA System Preparing Your Facility to Install the Viper Pro SLA System

Technical Specification Industrial Series - IS2 to IS48 Systems. CapDI Benefits. Feed Water Quality. Design and Scope of Supply.

Product data sheet DUMATHERM N Pro. for the automatic serial determination of NITROGEN

Hydrogen Generators. for GC combustion detector applications. Product Features: Contact Information: ENGINEERING YOUR SUCCESS.

General Plan OXYGEN SERVICE CONTAINER 2005 Version 1.02

CFFWA-20-1-U Chilled/Hot Water Universal Mount Fan Coil 2-Pipe Heat / Cool Fan Coil 60,000 BTUH

Gas Generator ULTRA HIGH PURE - HIGH FLOW. Gas Generator

INSTALLATION INSTRUCTIONS

Chlorinated Organics Closed Loop Unloading of Solvent Tank Trailers

UL RATED HEAT SHRINK TUBING

DIN Panels and Accessories

July P Wide Format Stacker User Guide

Thermo Scientific ThermoFlex Recirculating Chillers. Your success circulates at every degree

300828TWP INSTALLATION INSTRUCTIONS MODEL SUBMERSIBLE SUMP PUMP

Ecologix Environmental Systems, LLC

INSTALLATION INSTRUCTIONS. MODEL Version W SUBMERSIBLE SUMP PUMP

Zip Freestanding Chilled Water Systems

CH88 In Situ Flue Gas Oxygen Transmitter

OmniCenter/Color Touch

SPIRIT. Water purifier. Complete User Manual

PURELAB CHORUS SYSTEMS

ENVIRONMENTAL NOISE CONTROL FOR SEMICONDUCTOR MANUFACTURING FACILITIES

Agilent 2100 Bioanalyzer. Installation and Safety Guide

Ultra High Purity Hydrogen Generators

RHM80. High Flow Coriolis Mass Flow Meter. Features. Applications. Benefits

Your local nitrogen generation partner. i-flow. Nitrogen gas generation solutions for manufacturing & processing industries.

MODELS PH PH PH

SECTION Manufactured Metal Casework FLEXIBLE LABORATORY FURNITURE SYSTEM (OPTIMA) USA VERSION

Imperial Series. Model IMP-425/525/625/825/1000AP IMD-425/525/625/825/1000AP IMP-1025/1200/1500/2000AP IMD-1025/1200/1500/2000AP

Ventum Series. The new Generation Wood Gasification Boilers. Europe s Fastest Selling Wood Gasification Boiler.

Custom Systems Built to Exacting Client Specification

MASTER. Water Conditioning Corp. OPERATION MANUAL. PURO PRO 1200 SC Series Modular Reverse Osmosis System. January 2012 Version

ABB MEASUREMENT & ANALYTICS DATA SHEET. PGC5009 Fast process gas chromatograph

MV Product Specifications

ELVORON LU/LA ELEVATOR

Model BF 260 Incubators Avantgarde.Line with forced convection

Chloride/Sulfate Analyzer

Large University Central Chiller Plant Design Considerations

SMS 100 MERCURY ANALYZER SMS 100. Mercury analysis directly on solid samples from the undisputed leader in Atomic Spectroscopy

TriStar II Plus Surface Area and Porosity Analyzer

The Wrapper Experts! 220 Bayview Drive, Unit 16

configurable, innovative, performance Thermo Scientific ThermoFlex Series Recirculating Chillers Typical Applications Analytical Biotech Industrial

Model 140MX Flowmeter Functional Overview

MAX300-RTG PRODUCT NOTE. Real-Time Gas Analysis Process Automation and Control Product Quality Analysis. Industrial Process Mass Spectrometer

Nitrogen production plants HPN

Model FD 115 Drying and heating chambers Avantgarde.Line with forced convection

135 Prime Emissions level: EPA NSPS Stationary Emergency Tier 3

APPLICATIONS BENEFITS INTELLIGENT

BINAR Quick-Lift System

SECTION 1000 ENGINEERING SPECIFICATION: AIR STRIPPER (REMOVABLE TRAY)

REACTOR E-10. plural-component propor t i o n e r s

HAZADOUS LOCATION LED FLOOD LIGHT

VIBRAPAC 3 AT A TIME INSTALLATION MANUAL F9801US OCTOBER 1999 US$250

3.3 Guidelines for Performing Building Inspections All building inspectors should read and understand the following information:

AP-25 Plasma System AP-25 PLASMA THERMAL SPRAY SYSTEM

TYPICAL INSTALLATION INSTRUCTIONS

Agilent 8490G Coaxial Attenuators

SECTION PACKAGE BOOSTER PUMP STATIONS

Thermal Shock Chambers Air-to-Air

1400 Prime 1125 Continuous Emissions level: EPA NSPS Stationary Emergency Tier 2 2g TA Luft

Silica Analyzer. Automated Silica Measurement Dependable and Sensitive

Wrap for Round Module of Cotton specially designed for John Deere 7760, CP690, CS690 Cotton Harvesters. 360 of Wrapping Technology

PRODUCT INFORMATION. DWS Pallet MEASURING AND WEIGHING PALLETS AND OTHER BULKY FREIGHT ITEMS. Track and trace systems

MASTER. Water Conditioning Corp. OPERATION MANUAL. PURO PRO 1200 SCP Series Modular Reverse Osmosis System. January 2012 Version

SECTION VIBRATION ISOLATION

DATA SHEET PART NO. : C-552SRD-A G/W REV : A / 2

Rack Power Distribution Unit AP7562, AP7563, AP7564 General Information

MATERIALS OF CONSTRUCTION

Quick-Start Operating Guide Document No Process Gas Cooler Copyright 2010 Terra Universal Inc. All rights reserved. Revised October 2010

Transcription:

Thank you for purchasing an Agilent instrument. To get you started and to assure a successful and timely installation of your Agilent ICP-OES, please refer to this site preparation checklist. Correct site preparation is the key first step in ensuring that your instruments and software systems operate reliably over an extended lifetime. This document is a checklist that outlines the space, utilities, supplies and consumable requirements for your equipment for your site. This checklist includes information on these products G8010AA, G8011AA, G8012AA G8014AA, G8015AA and G8016AA Customer Responsibilities Make sure your site meets the following specifications before the installation date. For details, see specific sections within this checklist, including: The necessary laboratory bench space is available The environmental conditions for the lab and exhaust venting Laboratory gases and plumbing The power requirements related to the product (e.g., number & location of electrical outlets) The required operating supplies necessary for the product and installation Please consult Other Requirements section below for other product-specific information. Please follow the site preparation instructions provided in the 5100 and 5110 ICP-OES Site Preparation Guide, part number G8010-90001. This document is only an overview of the main requirements. Agilent Technologies service providers will not install your Agilent ICP-OES system until an adequate exhaust system is present and functioning. See Environmental Conditions section. If Agilent is delivering installation and familiarization services, users of the instrument should be present throughout these services; otherwise, they will miss important operational, maintenance and safety information. Important Customer Information 1. If you have questions or problems in providing anything described as a Customer Responsibilities above, please contact your local Agilent or partner support/service organization for assistance prior to delivery. In addition, Agilent and/or its partners reserve the right to reschedule the installation dependent upon the readiness of your laboratory. 2. Should your site not be ready for whatever reasons, please contact Agilent as soon as possible to reschedule any services that have been purchased. 3. Other optional services such as additional training, operational qualification (OQ) and consultation for user-specific applications may also be provided at the time of installation when ordered with the system, but should be contracted separately. 1 Page 1 of 6

Dimensions and Weight Identify the laboratory bench space before your system arrives based on the table below. Pay special attention to the total height and total weight requirements for all system components you have ordered and avoid bench space with overhanging shelves. Also, pay special attention to the total weight of the modules you have ordered to ensure your laboratory bench can support this weight. 1. The Agilent ICP-OES, its data system and accessories will be delivered to your site in large and small shipping containers. Note the size of the largest shipping container below. 2. The containers will be delivered in a large truck. You must furnish a forklift, or other suitable lifting device, and make arrangements to unload the truck and transport the containers to your site. All doorways, hallways, floors and elevators must be able to accommodate the largest, heaviest container. Do not open any of the shipping containers unless a representative of Agilent Technologies is present. Instrument Description Weight Height Depth Width Kg lbs mm in mm in mm in Largest shipping container 152 335 1225 48.2 910 35.8 945 37.2 5100, 5110 ICP-OES Mainframe 106 234 940 37 740 29.5 800 31.5 2 Page 2 of 6

Environmental Conditions Operating your instrument within the recommended temperature ranges ensures optimum instrument performance and lifetime. 1. Performance can be affected by sources of heat and cold (e.g., direct sunlight, heating/cooling from air conditioning outlets, drafts and/or vibrations). The site s ambient temperature conditions must be held constant to within ±2 C for optimum performance. 2. Maximum altitude up to 3000 m. 3. Recommended exhaust and venting requirements include: 2.5 m 3 /min > flow < 6.0 m 3 /min minimum (90 ft 3 /min > flow < 200 ft 3 /min) for 150mm diameter ducting. Exhaust flow must be continuous as long as the plasma is ON. Exhaust flow must be stable: maximum fluctuation of ±5% of flow. The ventilation ducting must have an ID of 150mm (5.9 inches). Flexible ducting must be used for easy removal during instrument maintenance. 4. User safety requires that the exhaust gases from the plasma be vented externally to the building and not re-circulated by the environmental control system. Health hazards include chemical toxicity of solvents and samples. 5. The customer is responsible for supplying the ductwork between the instrument and the lab extraction system. Instrument Description Operating temp range C (F) Operating humidity range (%) Heat Dissipation (Watts) Heat Adsorbed (Watts) 5100, 5110 ICP-OES 15-30 C (59-86 F) 25-80, non-condensing, non-corrosive 870 Maximum to room PC Monitor 430 (PC:365, Monitor:65) Agilent Chiller (G8481A) 2,000 max 1400 DV 900 Radial Extraction Vent 2030 max 3 Page 3 of 6

Power Consumption 1. If a computer system is supplied with your instrument, be sure to account for those electrical outlets. 2. Installation requires an isolated, noise free ground. 3. A power cable will be supplied based on your region. Please ensure the appropriate wall receptacle is provided. Part number Description Wall receptacle Length m (ft) 8120-8620 Power cord UK, Sing, Malay, HK, C19, 13A BS1363 2.5 m (8.2) 8120-8619 Power Cord, Australia, C19, 16 amp AS 3112 2.5 m (8.2) 8121-1222 Power Cord, Europe/Korea, C19, 16 amp CEE7/V11 2.5 m (8.2) 8120-8623 Power Cord, 250V US/Canada 15A NEMA 6-15R 2.5 m (8.2) 8120-6903 Power Cord, Japan, C19, 20 amp NEMA L6-20P 4.5 m (14.7) 8120-8622 Power Cord, Swiss/DK, C19, 16 amp Swiss/Denmark 1302 2.5 m (8.2) 8121-0710 Power Cord, India/S.Africa, C19, 15 Amp BS 546 2.5 m (8.2) 8121-0161 Power Cord, Israel, C19, 16 Amp Israeli SI32 2.5 m (8.2) 8121-0675 Power Cord, Argentina, C19, 20 amp AS 3112 2.5 m (8.2) 8121-0070 Power Cord, China, C19, 15 amp, Fast GB 1002 4.5 m (14.7) 8120-6360 Power Cord, Taiwan/S America, C19, 20A NEMA 5-20P 2.5 m (8.2) 8121-1301 Power Cord, Thai 220V, 15 A, 1.8M, C19 NEMA 5-15 1.8 m (5.9) 8121-1787 Power Cord, Brazil, C19 250V 16A Brazil 2.5 m (8.2) 4. Do not use extension cords with Agilent Technologies equipment. They cannot provide enough power to the system and can be a safety hazard. If the desired location of equipment does not permit its standard power cord to reach an electrical outlet, your electrician should install additional outlets. Otherwise, you should relocate the equipment closer to existing electrical outlets. Instrument Description 5100, 5110 ICP-OES, PC Monitor Printer Agilent Chiller (G8481A) Line Voltage & Frequency (V, Hz) 200-240 VAC ±10%, 50/60Hz Single phase 100-127VAC 200-240VAC 220-240 VAC, 50Hz 120 VAC, 60Hz Maximum Power Consumption (A) Nominal rating (VA) 15 2900 10 5 8.9 16 1000 1000 2140 1920 SPS 4 Autosampler 100-240 VAC 47-63Hz <1 60 SPS 3 Autosampler 100-240 VAC ±10%, 50-60 Hz <1 220 4 Page 4 of 6

Cooling Water Requirements 1. The preferred cooling system is the Agilent Chiller (G8481A), filled with Poly-Clear Fluid (G3292-80010). 2. If you are not using the preferred system, and another type of water re-circulator is used, the reservoir should be filled with distilled water having a conductance in the range of 50-150 µs. 3. Distilled water will keep the system clean. Do not use tap water as it will contaminate the system and do not use deionized water as it will corrode the system. Cooling Water Parameter Heat to be dissipated Flow Rate Pressure Temperature Conductivity Connections 1,400W for dual view instruments 900W for radial view instruments Specification 2.0 L/min (0.3 us gallons/min) minimum Inlet pressure 230-400kPa (33-58psi) 15-28 C, 20 C recommended at water inlet of ICP-OES 50-150μS at the chiller reservoir Hoses 5m (16.4 feet) long, 12mm ID, with 1/2 inch NPT male connectors 5 Page 5 of 6

Gas Requirements 1. The gas regulators should be within 3 meters (9.8 feet) of the ICP-OES. Compressed gas Purity Compressed Gas Assoc. Standard Argon 99.995% CGA 580 Nitrogen, Optional Polychromator Purge Gas Option Gas (If required for application) 99.995% CGA 580 Oxygen 20% Argon 80% 99.995% CGA 540 Typical Working Pressure kpa (psi) 500-600kPa (73-88psi) Recommended 550kPa (80 psi) 500-600kPa (73-88psi) Recommended 550kPa (80 psi) 500-600kPa (73-88psi) Recommended 550kPa (80 psi) Important Customer Web Links For additional information about our solutions, please visit our web site at http://www.agilent.com Need to know more? Customer Education http://www.agilent.com/crosslab/university/ Need supplies? - www.agilent.com/chem/supplies Document part number: G8010-90071 6 Page 6 of 6