FieldLink for PROFIBUS Applications

Similar documents
Cable solutions for Automation & Drives

Construction guideline

BUS CABLES. Content. IBL 600 PVC Interbus-Loop cable... E/11. S IBL 605 PUR Interbus-Loop cable for cable tracks... E/11

HELUKABEL CC-Link Certified Cables

Comparison of BS 5308, PAS 5308 and BS EN

Content HYBRID AND SPECIAL CABLES G 2 NEW NEW NEW NEW. page. Applications... G/3. Construction examples of special cables

The Company by Peter Bröckskes sen. an independent, middle sized company

Single core conductor BETAtherm 145

Instrumentation and Thermocouple Cables


Nominal Core OD Materials. Conductor (stranding) Diameter Nom. DCR

Content. PV1-F Halogen-free cable for photo-voltaic systems... G/11. PV1-F dual Halogen-free twin cable for photo-voltaic systems...

Compact Module. Enhanced Category 5 FTP Cabling System

Una e mpre sa Vi akab l e GLOSSARY.

Content. Festoon 715 P PUR cable for flexible application in festoon systems... G/21

Tailor-Made Cable Solutions

Cables & Accessories for Wind Turbines 2013 /

Industrial LSZH Loose Tube, Gel-Free, Double-Jacket Cable

Cables for Drag Chains

CONTENT. Robot cables. page. < The company < W - worldwide < Certifications < Clientele / supplier numbers... 6

H-FLEX CABLES 10/2017


Section ARMORED MEDIUM VOLTAGE CABLES SHIELDED 3 CONDUCTOR POWER CABLE - INTERLOCKED ARMOR

Instrumentation Cables

PRODUCT SELECTION LOCATOR

Your Partner for Custom Interconnectivity Solutions. ISO 9001 AS9100C ISO ISO Qualified

Conductor Shield A combination of semi-conducting tape and extruded thermosetting semi-conducting material meeting UL 1309, IEEE 1580 and UL1072.

FLEXIBLE CONDUITS AND CONNECTORS

Inside Wire. Wire & Cable. Category 6 Plus Plenum. Category 6 Plus Riser. PREMIER Category 6 CMP/CMR

SECTION INSULATED WIRE AND CABLE

3M Round, Shielded/Jacketed, Flat Cable.050" 28 AWG Stranded, Mass Terminatable, PVC/PVC 3659 Series

IEEE 1580 Type P MOR Polyrad XT-125 Multi Conductor

PHOTOVOLTAIC CABLES. Energy and Fiber Optical Cables for Solar Energy Systems.

SECTION LOW-VOLTAGE ELECTRICAL POWER CONDUCTORS AND CABLES (24 Volt AC/DC or Less)

D Side lap. Side lap screw spacing < 500mm factory-installed seals on side lap. Decoupling tape > 60mm

etwork etwork-/ethernet-/foc-cable

Ceramic Ceramic No. of Lead/Wire Lead Allied RS order Dia Ø Length Wires Type Length Code code

15 Pin DSUB - MALE 15 Pin DSUB - FEMALE 9 Pin DSUB - MALE 9 Pin DSUB - FEMALE

Mineral Insulated Platinum Resistance Thermometer PT100 Sensor - Available in 3mm or 6mm diameter x 150mm or 250mm probe lengths

Platinum Resistance Pt100 Autoclave Drain Probe, 4 Wire Compatible with most common makes of Autoclaves

Glossary Of Terms M-1

Armoured Instrumentation Cables to BS7917

Insulation in decks and bulkheads PYROLIQ sealing compound system

Detailed Specifications & Technical Data

Pipe Protection Tape System

ENGINEERING COMMITTEE Interface Practices Subcommittee AMERICAN NATIONAL STANDARD. ANSI/SCTE (Formerly IPS SP 100)

DESIGN GUIDELINES WIRING AND CONDUITS PAGE 1 of 7

catalog Copper Wires

*** Supercedes: BECO E and COM , , & ***

ANSI/NEMA WC ICEA S Standard for Control, Thermocouple Extension, and Instrumentation Cables

Platinum Resistance Pt100 & Pt1000 Silicone Patch Sensors Element Encapsulated in A Silicone Rubber Patch with Self-Adhesive Aluminium Foil Backing

ABOUT US. Unit II: Halol, Gujarat. (Semi conductive compounds) (HFFR Halogen Free Flame Retardant)

ENGLISH Datasheet Platinum Resistance Pt1000 Class B Sensor with Teflon insulated lead

Product Selection Guide. Color & Additives - Europe. Color & Additives. Concentrates for the Wire & Cable Industry

Datasheet Platinum Resistance Pt100 Dual Element Industrial Sensor Probe 6mm diameter x 150mm or 250mm probe lengths

ANSI/NEMA WC 71 ICEA S Nonshielded Cables Rated V for Use in the Distribution of Electric Energy

FLAMABILITY TESTS FOR ELECTRICAL CABLES

ENGLISH. 1metre 7/.02mm Teflon insulated twin twisted lead

ENGLISH Datasheet Platinum Resistance Pt100 Hygienic Thermometer, 1.5'' RJT style fitting

NUCLEAR POWER CORPORATION OF INDIA LTD. (A GOVT. OF INDIA ENTERPRISE) SPECIFICATION NO.PB-E-542/REV. No.0

America s Wire Company

MEDIUM VOLTAGE XLPE INSULATED POWER CABLES [6.35/11kV Copper XLPE Three-Core HDPE Sheathed]

Cables for Railway Signalling Applications General Requirements

Tubes et tuyaux techniques Polígono Indutrial O Rebullón s/n Mos - España -

7. EXTENSION LEADS AND COMPENSATING CABLE

FINOLEX FLAME RETARDANT (FR) PVC INSULATED INDUSTRIAL CABLES FINOLEX FLAME RETARDANT (FR) PVC INSULATED INDUSTRIAL CABLES - PROJECT PACKING

Specifications: Ice point resistance: Fundamental interval (0 C to 100 C): 38.5Ω (nominal)

PLASTIC CONDUIT SYSTEMS 1 MADE FROM PVC 4 2 MADE FROM HALOGEN FREE RAW MATERIALS 18 3 WITH ANTIMICROBIAL PROTECTION 30 4 BURIED UNDERGROUND 42

3M Electromagnetic Compatible Products

PT. KABELINDO MURNI Tbk SHIPBOARD CABLE WIRE AND CABLE MANUFACTURER. No. EMS No. OSH No. QCS 00152

Shipboard and Offshore Cables

Fibre optic cables CTC LSZH 1,2kN

ENGLISH Datasheet Platinum Resistance Pt100 & Pt1000 Thin Film Detectors Platinum Sensing Resistors Thin Film (Pt100 & Pt1000 Ohm)

3M Ground Plane Cable.050" 28 AWG Stranded, One Drain, PVC 3476 Series

TEWA ELECTRONICS GROUP HIGH PRECISION NTC THERMISTORS AND TEMPERATURE SENSORS

SECTION WIRE AND CABLE Raceways and Conduit Motor Power and Control Wiring.

DMRC ELECTRICAL STANDARDS & DESIGN WING (DESDW)

Technical Tubing and Hose

SECTION HEAT TRACING FOR PLUMBING PIPING

UNIFIED FACILITIES GUIDE SPECIFICATIONS

Single-Jacketed Tubing

DETAIL SPECIFICATION SHEET CABLE, ELECTRICAL, TYPE LSC5FS (INCLUDING VARIATIONS LSC5FSW, LSC5OS, AND LSC5OSW)

CONSTRUCTION SPECIFICATION FOR INSTALLATION OF CABLE

Cable accessories for shipbuilding and off-shore units

USB Connectors. USB Connectors. Interconnect Solutions Worldwide. D38999 Derived USB-A & USB-B Connector Assemblies for Harsh Environments

1. Division 23 Section "Hangers and Supports for HVAC Piping and Equipment" for pipe insulation shields and protection saddles.

Engineering Data for Copper and Aluminum Conductor Electrical Cables

Protective Tubing. Comprehensive range of HEAT-SHRINKABLE and COLD APPLIED TUBING

FIRESTOP AND FIRE PROTECTION

SECTION HVAC INSULATION

Technical Bulletin #27 Wiring for Architectural Applications

11-SDMS-01 REV. 02 SPECIFICATIONS FOR LOW VOLTAGE POWER AND CONTROL CABLES

SECTION THROUGH-PENETRATION FIRESTOP SYSTEMS

BASIC CONCEPTS IN ELECTRICAL DESIGN. Prepared by Engr. John Paul Timola

IPC A Guideline for Defining "Low- Halogen" Electronic Products. Working Draft. IPC-4903 August August 2010

TS 804 CABLES TABLE OF CONTENTS TRAFFIC SIGNAL EQUIPMENT POLE WIRING DIAGRAM LOCATIONS WITH CENTRE MEDIANS

O Coaxial/Fiber/Microduct Hybrid Buried Cable. Serves businesses in a new commercial serving area. Mitigates future cost of fiber installation

STATE UNIVERPROGRAM DIRECTIVES

INTERNATIONAL STANDARD

Transcription:

FieldLink for PROFIBUS s The Automation & Drives business unit of LEONI has developed FieldLink bus cables in accordance with the PROFIBUS specifications. The FieldLink bus cable product range for PROFIBUS systems comprises shielded twisted pair cables with circular cross-section as standard type; with Polyethylene or Polyurethane jacket, halogen-free versions, buried or drum cables, cables specially made for hazardous areas or cables with double jackets separated by a steel-tape armour offering total rodent protection. FieldLink ES cables (easy to strip) for PROFIBUS standard can be quickly and easily cut to length and terminated on site with the PROFIBUS ES system for fast installation. For this, LEONI offers a stripping tool with the help of which installation time can be significantly reduced. FieldLink bus cables are developed for PROFIBUS DP and PROFIBUS PA applications. PROFIBUS DP is optimized for factory automation whereas PROFIBUS PA is made for the process automation in hazardous and intrinsically safe areas. : Flame retardant Weld splatter resistant Highly flexible Permanent installation Halogen free Silicon free Sunlight resistant Oil resistant Cold resistant Chemical resistant Insulation integrity (90 min) Direct burial EMC cable for electromagnetic compatibility Festoon cable Torsional stress cable Trailing cable with up to 5 million bending cycles RoHS compliant LEONI Special Cables is a member of PROFIBUS International www.profibus.com 14 LEONI

PROFIBUS DP ES PROFIBUS DP ES PROFIBUS DP ES ES cable for permanent installation ES cable for permanent installation ES sturdy cable for chemical (easy to strip) (easy to strip, FRNC) and mechanical stress (easy to strip, FRNC) UL listed: CMG and CL3 UL listed: CM UL listed: CMX inner jacket: FRNC Thermoplastic copolymer (FRNC) violet Polyurethane (PUR) violet Flame retardant acc. to IEC 60332-3-24 Flame retardant acc. to. IEC 60332-1-2, and UL 1685 (CSA FT 4), halogen free, cold bending resistant acc. to IEC 60811-1-4, cold bending resistant acc. to IEC 60811-1-4, sunlight resistant acc. to UL 1581, Sec. 1200, sunlight resistance acc. to UL 1581 Sec. 1200, limited oil resistant, mineral oil and fat resistant, UL-File E119100 Vol. 1 Sec. 16 Page 7, UL 1685 (vertical tray), UL-File E119100 Vol. 1 Sec. 8 Page 1 UL-File E116441 Vol. 1 Sec. 6 Page 7, corrosivity of fire gases acc. to IEC 60754-2, UL-File E119100 Vol. 1 Sec. 11 Page 1 02YSY(ST)CY 1x2x0.64/2.55-150 VI KF40 FR 02YSH(ST)CH 1x2x0.64/2.55-150 VI KF25 FRNC 02YSY(ST)C11Y 1x2x0.64/2.55-150 VI KF40 FR L45467-G16-C185 L45467-G16-C286 L45467-G16-C118 LEONI 15

PROFIBUS DP ES PROFIBUS DP ES PROFIBUS DP ES ES cable for food industry (easy to strip) ES cable for direct burial (easy to strip) ES trailing cable (easy to strip, FRNC) Similar to 1x2x23AWG 19 UL listed: CMX (0.006 in), Ø 0.65 mm (0.026 in), Polyethylene (PE) black Inner jacket: Polyurethane (PUR) petrol Outer jacket: Polyethylene (PE) black Ø 10.8 ± 0.5 mm (0.425 ± 0.020 in) Cold bending resistant acc. to IEC 60811-1-4, Cold bending resistant acc. to IEC 60811-1-4, cold bending resistant acc. to IEC 60811-1-4, limited mineral oil and fat resistant limited mineral oil and fat resistant mineral oil and fat resistant, UL-File E119100 Vol. 1 Sec. 8 Page 1 also available as a CMG version 02YSY(ST)C2Y 1x2x0.64/2.55-150 KF40 02YSY(ST)CY2Y 1x2x0.64/2.55-150 KF40 02YY(ST)C11Y 1x2x0.65/2.56-150 LI KF40 FR petrol L45467-G16-C246 L45467-G16-C236 L45467-G16-C98 16 LEONI

PROFIBUS DP ES PROFIBUS DP PROFIBUS DP ES cable for flexible installation (easy to strip) Cable for permanent installation Cable for permanent installation (FRNC) Similar to 1x2x23AWG 19 UL listed: CMG and CL3 UL listed: CMG and PLTC (0.006 in), Ø 0.67 mm (0.026 in), Ø 2.56 mm (0.101 in) 2 wires twisted to a pair with fillers in gaps 2 wires twisted to a pair with fillers in gaps Thermoplastic copolymer (FRNC) violet Flame retardant acc. to IEC 60332-3-24 Flame retardant acc. to IEC 60332-3-24 Flame retardant acc. to IEC 60332-3-24, and UL 1685 (CSA FT 4), and UL 1685 (CSA FT 4), halogen free, cold bending resistant acc. to cold bending resistant acc. to IEC 60811-1-4, DIN VDE 50290-2-22, smoke density acc. to IEC 61034 limited oil and fat resistant, UL-File E119100 Vol. 1 Sec. 16 Page 7, UL-File E119100 Vol. 1 Sec. 16 Page 7, UL-File E116441 Vol. 1 Sec. 6 Page 7, UL-File E116441 Vol. 1 Sec. 6 Page 7, 02YSY(ST)CY 1x2x0.65/2.55-150 LI VI 02YS(ST)CY 1x2x0.64/2.55-150 VI KF40 FR 02Y(ST)CH 1x2x0.64/2.55-150 VI FRNC KF25 L45467-G16-C375 L45467-G16-C145 L45467-G16-C206 LEONI 17

PROFIBUS DP PROFIBUS DP PROFIBUS DP Cable for permanent installation (FRNC) High temperature cable Cable with rodent protection (FE90: insulation integrity 90 minutes) for permanent installation for permanent installation insulation of foamed FEP flame protection foil overlapped Ø 2.75 mm (0.108 in) 2 wires twisted to a pair with fillers in gaps 2 wires twisted to a pair with fillers in gaps 2 wires twisted to a pair with fillers in gaps of tinned copper wires Ø 0.15 mm (0.06 in),, violet, Ø 8.0 ± 0.4 mm flame protection foil overlapped (0.315 ± 0.016 in), armouring: 2 layers galvanized steel tape, intercalated tapes Thermoplastic copolymer (FRNC) grey Perfluorethylenepropylene (FEP) violet Polyethylene (PE) black Ø 8.8 ± 0.4 mm (0.346 ± 0.016 in) Ø 7.2 ± 0.25 mm (0.283 ± 0.010 in) Ø 10.8 ± 0.5 mm (0.425 ± 0.020 in) Insulation effect under fire Oil resistant, Sunlight resistant, conditions acc. to IEC 60331, limited mineral oil and fat resistant halogen free high temperature range (up to 180 C) 02YS(ST)CH 1X2X0.64/2.55-150 06Y(ST)C6Y 1x2x0.64/2.55-150 VI 02YS(ST)CYB2Y 1x2x0.64/2.55-150 (2B0.1VZK) GR FRNC FE 90 L45467-G16-C266 L45467-G16-N17 L45467-G16-C276 18 LEONI

PROFIBUS DP PROFIBUS DP PROFIBUS DP EMC cable for permanent installation (electro- Trailing Cable (FRNC) Festoon cable magnetic compatibility) or for direct burial Similar to 1x2x23AWG 19 Similar to 1x2x23AWG 19 UL listed: CMX UL listed: CMG and CL3 (0.006 in), Ø 0.64 mm (0.025 in), (0.006 in), Ø 0.65 mm (0.026 in), Ø 2.56 mm (0.101 in) 2 wires twisted to a pair with fillers in gaps, tinned copper drain wire 2 wires twisted to a pair with fillers in gaps 2 wires twisted to a pair with fillers in gaps copper tape longitudinal welded and spiral corrugated of tinned copper wires Ø 0.1 mm (0.004 in) Polyurethane (PUR) petrol Polyvinylchloride (PVC) petrol Ø 11.1 ± 0.3 mm (0.437 ± 0.012 in) Ø 8.5 ± 0.4 mm (0.335 ± 0.016 in) Ø 8.0 ± 0.3 mm (0.315 ± 0.012 in) Flame retardant acc. to UL 1685 (CSA FT4), sunlight resistant halogen free, oil resistant acc. to UL 758 Sec. 15, oil resistant acc. to DIN EN 60811-2-1, UL-File E119100 Vol. 1 Sec. 16 Page 6, smoke density acc. to IEC 61034, UL-File E116441 Vol. 1 Sec. 6 Page 6, UL-Style E119100 Vol. 1 Sec. 8 Page 1 02YS(ST)WKY 1x2x0.64/2.55-150 VI KF40 FR 02YS(ST)C11Y 1X2X0.64/2.55-150 02YS(ST)CY 1x2x0.65/2.56-150 LI petrol FR LI FRNC petrol L45467-G16-C355 L45467-G16-C88 L45467-G16-C255 LEONI 19

PROFIBUS DP PROFIBUS DP-Desina PROFIBUS DP-Desina Torsional stress cable (FRNC) Hybrid cable for trailing application Hybrid cable for trailing application (FRNC) 9 1x2x24AWG 19 + 4x1.5 mm² (0.059 square in) 1x2x24AWG 19 + 4x1.5 mm² (0.059 square in) UL listed: CMX UL listed: CMG and CL3 UL recognized: AWM Stranded bare copper wire 19x0.16 mm Wire LIY 1.5/2.4 Wire LIH 1.5/2.4 (0.006 in), Ø 0.8 mm (0.031 in), Stranded bare copper wire 84x0.15 mm Stranded bare copper wire 84x0.15 mm (0.006 in), Ø 1.6 mm (0.063 in), (0.006 in), Ø 1.55 mm (0.061 in), Ø 2.56 mm (0.101 in) insulation of PVC Ø 2.4 mm (0.094 in) insulation of FRNC Ø 2.4 mm (0.094 in) Wire 02Y 0.65/2.56 LI Wire 02Y 0.65/2.56 LI (0.006 in), Ø 0.65 mm (0.256 in), (0.006 in), Ø 0.65 mm (0.256 in), Screened pair 02Y(ST)C Screened pair 02Y(ST)C alulaminate foil over- alulaminate foil over- lapped, of tinned copper wires lapped, of tinned copper wires Ø 0.15 mm (0.006 in) Ø 0.15 mm (0.006 in) 2 wires twisted to a pair with fillers in gaps 1 screened pair, 4 wires 1 screened pair, 4 wires 2 layers of plastic tape conductive, Polyurethane (PUR) violet Polyurethane (PUR) violet Ø 11.0 ± 0.3 mm (0.433 ± 0.012 in) Ø 11.0 ± 0.3 mm (0.433 ± 0.012 in) Flame retardant acc. to UL 1685 (CSA FT4), halogen free, oil resistant acc. to IEC 60811-2-1 oil resistant acc. to UL 1581 Sec. 480, oil resistant acc. to IEC 60811-2-1, and UL 1581 VW 1, UL-File E119100 Vol. 1 Sec. 16 Page 1, UL-File E119100 Vol. 1 Sec. 8 Page 1 UL-File E116441 Vol. 1 Sec. 6 Page 1, UL-Style 21198 02YS(ST)C11Y 1x2x0.8/2.56-150 LI FR VI 02Y(ST)C 1x2x0.65/2.56-150 LI 02Y(ST)C 1x2x0.65/2.56-150 LI LIY-ZY 4x1x1.5 VI LIH-Z 11Y 4x1x1.5 VI FRNC L45467-G18-C18 L45467-G116-W45 L45467-G116-W58 20 LEONI

PROFIBUS DP-ET 200X PROFIBUS DP-ET 200C Hybrid cable for trailing application (FRNC) 9 + 3x0.75 mm 2 (0.030 square in) UL recognized: AWM Hybrid cable for permanent and flexible installation, 9 + 3x0.75 mm 2 (0.030 square in), UL recognized: AWM Wire LIY 0.75/1.7 Stranded bare copper wire 24x0.2 mm (0.008 in), Ø 1.15 mm (0.045 in), insulation of PVC Ø 1.7 mm (0.067 in) Wire 02Y 0.65/2.56 LI Stranded bare copper wire 19x0.13 mm (0.005 in), Ø 0.65 mm (0.256 in), Screened pair 02Y(ST)C alulaminate foil overlapped, of tinned copper wires Ø 0.15 mm (0.006 in) Wire LIY 0.75/1.7 Stranded bare copper wire 24x0.2 mm (0.008 in), Ø 1.15 mm (0.045 in), insulation of PVC Ø 1.7 mm (0.067 in) Wire 02YS 0.25/2.56 LI Stranded bare copper wire 19x0.13 mm (0.005 in), Ø 0.65 mm (0.256 in), Pair 02YS 2 wires twisted to a pair 1 pair twisted, 3 wires 1 pair twisted, 3 wires braiding of tinned copper wires Ø 0.15 mm (0.006 in) Polyurethane (PUR) petrol, Ø 9.5 ± 0.5 mm (0.374 ± 0.020 in), also available with PVC jacket for permanent and flexible installation Polyvinylchloride (PVC) petrol, Ø 8.0 ± 0.4 mm (0.315 ± 0.016 in), also available with PUR jacket for trailing applications oil resistant acc. to IEC 60811-2-1, UL-Style 20351 UL-Style 2464 02Y(ST)C 1x2x0.65/2.56-150 LI LIY-J 11Y 3x1x0.75 petrol 02Y 1x2x0.65/2.56-150 LI LIY-J CY 3x1x0.75 petrol L45467-G116-W38 L45551-W59-W15 LEONI 21