F-SERIES: F SPECIFICATIONS Four-Fold Door Systems

Similar documents
N-SERIES: NTH3500 SPECIFICATIONS Hollow Metal Sliding Door System

LTH3700, HOLLOW METAL SLIDING FIRE DOOR

FOUR FOLD DOORS-WITH SINGLE OVERHEAD MTD OPERATOR

SECTION SECTIONAL OVERHEAD DOORS

SECTION SECTIONAL OVERHEAD DOORS 522 SERIES ALUMINUM SECTIONAL OVERHEAD DOORS. Display hidden notes to specifier. (Don't know how?

Series - 1

SECTION [ ] COILING COUNTER DOORS. Display hidden notes to specifier. (Don't know how? Click Here)

SST-II HYDRAULIC BI-FOLD SPECIFICATIONS

AJONES AIRWAYS, LLC CLEVELAND REGIONAL JETPORT Sliding Hangar Doors SBA SECTION SLIDING HANGAR DOORS

This guide can be used to prepare a specification for incorporating free standing jib cranes into a competitively bid construction project.

A. Product Data shall be provided for each type of product indicated.

FABRICOIL BASIC January 10, 2006

MODERNFOLD GWS 100SR-G MOVEABLE GLASS WALLS

This guide can be used to prepare a specification for incorporating free standing jib cranes into a competitively bid construction project.

Series - 1

UNIFIED FACILITIES GUIDE SPECIFICATIONS

SECTION OVERHEAD COILING FIRE DOORS MODEL 662 OVERHEAD COILING COUNTER FIRE DOORS WITH INTEGRAL FRAME

SECTION OVERHEAD COILING DOORS 610 SERIES SERVICE DOORS. Display hidden notes to specifier by using Tools / Options / View / Hidden Text.

SECTION ACCORDION FOLDING PARTITIONS

WALL MOUNTED ARTICULATING JIB CRANE

Section SECTIONAL INSULATED STEEL DOORS

SECTION RADIO FREQUENCY SHIELDING ENCLOSURE RF Welded System

SECTION SECTIONAL OVERHEAD DOORS

Page 1 PRODUCT DESCRIPTION SECTION SECTIONAL OVERHEAD DOORS MODEL 900 PRODUCT FEATURES

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017

Westgate Entrematic, Parking Security Gates Section OVERHEAD SECURITY GATE Prepared by: Digicon Information Inc. Page 1

SINGLE SWING DOOR PAIRED SWING DOOR

C. Section Metal Fabrications: Steel frame and supports.

SECTION ROOF ACCESSORIES

800 Series Aluminum Overhead Doors, by Northwest Door Section ALUMINUM SECTIONAL DOORS Digicon Information Inc.

DIVISION 10 SPECIALTIES SECTION OPERABLE PARTITIONS

1. Vertical reciprocating conveyor, Hydraulic straddle VRC.

FoldingAccess Series Aluminum Folding Door System

HIGH MAST CAMERA POLE ASSEMBLY GENERAL

Therma Series Insulated Overhead Doors, by Northwest Door Section SECTIONAL DOORS Digicon Information Inc.

Signature Series 5 Lap SECTION ALUMINUM WINDOWS

UNIFIED FACILITIES GUIDE SPECIFICATION

UFGS (April 2006) UNIFIED FACILITIES GUIDE SPECIFICATIONS

G. UNDERWRITERS LABORATORY, INC.: 1. UL 325: Electrical Door, Drapery, Gate, Louver, and Window Operators and Systems

COLLEGE CLASSROOM & DORMITORY SPECIFICATION SECTION 08100

SECTION CRL50 AND CRL51 HEAVY GLASS TOP HUNG SLIDING DOOR SYSTEMS

SECTION Summit Phenolic Lockers (Solid Phenolic Lockers)

ANSI/ ASME HST Performance Standard For Overhead Electric Wire Rope Hoists

VPL-3200B Residential Vertical Platform Lift Technical Specifications

HD-Swing Series 4000 Heavy Duty Aluminum Swing Door System with Electric Operator

SECTION MECHANICAL SPECIFICATION GRIT COLLECTION EQUIPMENT

A. AMERICAN ARCHITECTURAL MANUFACTURERS ASSOCIATION (AAMA): 101 Appendix Dissimilar Materials.

Series 3000 Pocket Doors

SECTION RADIATION SHIELDING ENCLOSURE Low Intensity Radiation Protection

SECTION ALUMINUM GATES

SECTION ORNAMENTAL ALUMINUM FENCING

SECTION CHAIN LINK FENCES AND GATES (PARK)

SECTION CHAIN-LINK FENCES AND GATES 02821/1

A. This Section includes automatic entrance door systems operating as follows: 1. Swinging operation.

Specifications for FL-100 Soffit Panel

SECTION ALUMINUM STORM WINDOWS

Architectural Single-Hung Aluminum Window Series L701T SH-AW130 GUIDE SPECIFICATION

SECTION ALUMINUM-FRAMED ENTRANCES AND STOREFRONTS PART 1 - GENERAL 1.1 SUMMARY. A. Section Includes:

PASSAIC COUNTY TECHNICAL INSTITUTE CCA 1422 NEW S.T.E.M. BUILDING 2017

SECTION BASIC ELECTRICAL MATERIALS AND METHODS

A. AMERICAN ARCHITECTURAL MANUFACTURERS ASSOCIATION (AAMA) 101: Appendix Dissimilar Materials.

GUIDE SPECIFICATION EXETER VERSA SHIELD SECURITY SCREEN SYSTEM

SECTION PRE-ENGINEERED MEMBRANE STRUCTURE

PF-Series Gantry Crane

SECTION RESIDENTIAL OVERHEAD DOORS SIGNATURE COLLECTION WOOD GARAGE DOORS

A. Access doors and frames are part of an access door and frame allowance.

Superior Aluminum Guide Specification 10/4/2016 Non-Welded Aluminum Pipe Railing

SECTION ENTRANCE FLOOR GRILLES STAINLESS STEEL GRATING

Model 4010 Individual Panels / Curve & Diverter

HD-Slide Series 2001 Heavy Duty Aluminum Sliding Door System with Electric Belt Drive Operator

SECTION ROLLER GATES

EDGEWATER, FLORIDA JUNE 14, 2010

Acousti-Seal Encore Paired Panel (10650) Operable Partitions

SECTION LOUVERS AND VENTS

1. Base plates, setting plates and anchor rods for columns. 8. Lintels if connected to structural steel columns.

SECTION LAGUNA SERIES TOP HUNG SLIDING DOOR SYSTEM

Central Dartmouth Section Exterior Envelope Renovations METAL-CLAD WOOD DOORS Page 1 of 5 Dartmouth, NS

SECTION VIBRATION CONTROLS FOR HVAC PIPING AND EQUIPMENT

SECTION INSULATED ROLLING SERVICE DOORS

Hardware. A. PRODUCT DATA: Submit manufacturer's technical information for each item of hardware.

SECTION METAL FABRICATIONS

Specifiers: Click on the icon in the WORD toolbar to reveal detailed instructions

SECTION TURBINE VENTILATORS

MARLIN WINDOWS, INC 3500 HC SERIES 3 3 8" SLIDING WINDOW PAGE 1

NORTH HARRIS COUNTY REGIONAL WATER AUTHORITY PIPE HANGERS, Section PIPE HANGERS, SUPPORTS, AND RESTRAINTS

SECTION MODULAR GALVANIZED RF SHIELDING SYSTEM SPECIFICATIONS

1. Section Steel Doors and Frames. 2. Section Flush Wood Doors 3. Section Aluminum Storefront Doors.

SECTION ALUMINUM-FRAMED STOREFRONTS

SECTION ACOUSTICAL PANEL CEILINGS

AMBICO Limited Section and RFI\EMI SHEILDED STEEL DOOR AND FRAME ASSEMBLIES Page 1

Specifications PRE ASSEMBLED DOOR SPECIFICATION PART 1 GENERAL 1.01 SUMMARY

Houston Community College 3200 Main Parking Garage November 15, 2010 Houston Community College

B. Polyethylene samples shall be submitted for Owner approval of color and quality.

Union County Vocational - Technical Schools Scotch Plains, New Jersey

SECTION LIGHT DUTY SLIDING AND STACKING GLASS DOOR SYSTEMS

UNIFIED FACILITIES GUIDE SPECIFICATIONS


Aluminum-Framed Entrances and Storefronts

A-Series Aluminum Gantry Crane

SECTION ACCESS PANELS

Transcription:

Version 5.22.13 F-SERIES: F100-600 SPECIFICATIONS Four-Fold Door Systems OPTIONS ARE IN BOLD, PLEASE MODIFY THESE AREAS AS NEEDED BASED ON YOUR PROJECT. CONSULT MANUFACTURER FOR ADDITIONAL OPTIONS OR MODIFICATIONS. PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 1 Specification Sections, apply to this Section. 1.2 SUMMARY A. This Section includes Four-Fold metal doors with surface mounted tube frames. B. Operation of Four-Fold metal doors includes overhead mounted electromechanical operators. 1.3 SUBMITTALS A. General: Submit each item in this Article according to the Conditions of the Contract and Division 1 Specification Sections. B. Product Data for each type of product specified consisting of manufacturer s technical Product Data and installation instructions for each type of door required, including data substantiating that products comply with requirements. C. Submittal Drawings showing fabrication and installation of Four-Fold metal doors including plans, elevations, sections, details of components, hardware, operating mechanism, and attachments to the other units of Work. Include wiring diagrams for coordination with electrical trade. D. Reference list including (5) successful installations of this type of door within the past two (2) years. 1.4 QUALITY ASSURANCE A. Doors shall be designed to withstand external or internal horizontal wind loads of 20 pounds minimum per square foot. The maximum allowable deflection shall not exceed 1/120 of the span. Fiber stresses in main members shall be limited to FF100-600 SERIES, FOUR-FOLD DOORS 1

27,000 pounds per square inch. Steel frames shall be designed in accordance with the AISC Steel Construction Manual. B. Door manufacturer shall have at least 10 years experience in manufacturing door type specified for emergency vehicle applications. 1.5 DELIVERY, STORAGE AND HANDLING A. Store delivered materials and equipment in dry locations with adequate ventilation, free from dust and water, and so as to permit access for inspection and handling. B. Handle materials carefully to prevent damage. 1.6 WARRANTY A. The door manufacturer shall provide a written standard limited warranty for material and workmanship. PART 2 - PRODUCTS 2.1 MANUFACTURERS A. Manufacturers: Four-Fold industrial metal doors manufactured by Door Engineering and Manufacturing, 400 Cherry Street, Kasota, MN 56050, (800)- 959-1352 or equal products by other manufacturers approved in advance. 2.2 MATERIALS Series (Choose one): FF100 Series: Solid Sheeted FF200 Series: Grille Inserts FF300 Series: Glazed FF400 Series: Sallyport, Solid Sheeted FF500 Series: Sallyport, Grille FF600 Series: Sallyport, Glazed A. Steel Tube: ASTM A513 and ASTM A500/A500M B. Steel Sheets: Steel sheets of commercial quality, complying with ASTM A1011/A1011M hot-rolled steel sheet. C. Hardware: Manufacturer s standard components. D. Fasteners: Zinc-coated steel. FF100-600 SERIES, FOUR-FOLD DOORS 2

2.3 FOUR-FOLD DOORS A. Construction: Door framing shall be minimum 14-gauge structural steel tube with 14-gauge steel sheet on the exterior and interior faces. Sheeting shall be formed on the vertical edges with no visible welds on the interior or exterior panel faces. All frames and framing members shall be true to dimension and square in all directions, and no door shall be bowed, warped, or out of line, in the vertical or horizontal plane of the door opening by more than 1/8 inch in 20 feet. Exposed welds and welds which interfere with the installation of various parts shall be ground smooth and flush. B. Surface Mounted Tube Frame: Supply pre-hung tube frame system constructed of minimum TS6x4x0.25, designed to anchor to masonry wall construction or weld to steel structure. All hinges, track supports and operator supports shall be factory attached. C. Factory finish: Option 1: Manufacturer s standard structural primer, field painting specified in section XXXXX. Option 2: All exposed steel shall be finished with manufacturer s standard epoxy primer and polyurethane top coat. Customer to select from Manufacturer s standard color chart. D. Operating Hardware: Hardware shall include guide tracks and brackets, trolleys, center guides, not less than three pairs of jamb and fold hinges per opening, and all bolts, nuts, fasteners, etc. necessary for complete installation and operation. Jamb hinges shall be dual shear and have two thrust bearings and two needle bearings. Jamb hinges shall be gusseted. Fold hinges shall be dual shear with two thrust bearings. All bearings shall be completely concealed within the hinge barrel and include grease zerks. All hinge pins shall be minimum ¾ diameter hardened steel. E. Weatherstripping: Material shall be adjustable and readily replaceable and provide a substantially weather-tight installation. Weatherstripping at center shall be 1/16 cloth inserted neoprene and include no exposed fasteners on the exterior face of the panel. Weatherstripping at sill shall include two 1/16 cloth inserted neoprene sweeps with an aluminum retainer. The retainer shall be attached to the door with adhesive. F. Perimeter Weatherstripping: Provide jamb and head weatherstipping of 1/16 cloth-inserted neoprene bulb (or closed cell neoprene). G. (Option) Vision Panels or Grilles: Provide 1 insulated vision panels or grilles of the size, shape and location as noted on the drawings. 2.4 OPERATOR A. Each Four-Fold door shall be operated by an overhead mounted electromechanical drive unit designed for high cycle operation. Operator consists of an electric motor, gear reducer, and rotating drive arm. The door shall be operated with connecting rods attached to the rotating drive arm on the operator and to FF100-600 SERIES, FOUR-FOLD DOORS 3

control arms attached to the jamb door section and to the door lintel. The connecting rods shall be positive drive, keeping the door under firm control at all times. The connecting rods shall be fitted with spherical bearings and control arms shall be equipped with oil impregnated bronze bearings on polished shafts. B. Operator shall be instantly reversible, open and close rapidly and start and stop gradually. Operator shall be adjustable to allow door to fully clear the opening. Operator shall automatically lock the door in the closed position. Operator shall be equipped with disengaging mechanism to convert to free wheeling mode for manual operation. C. Operator shall include a formed hood enclosing the motor, gearboxes and limit switches. D. Electric motor shall be of sufficient size to operate doors under normal operating conditions at no more than 75 percent of rated capacity. The motor shall be wound for three phase 208/230/480 VAC, 60 Hertz operation. E. Electric Controls: Controls shall be furnished by the door manufacturer and shall be complete for each door, and built in accordance with the latest NEMA standards. Incoming electrical shall be (Choose One): 120VAC single phase, 208VAC single phase, 208/230VAC 3-phase, 480VAC 3-phase. 1. Controls shall include a programmable logic controller with digital message display or LED indicators. Controller shall include programmable close timers and programmable inputs/outputs. 2. Motor starters shall be magnetic reversing, factory wired with overload and under voltage protection, and equipped with mechanical interlocks. All control components shall be enclosed in one enclosure with a wiring diagram placed on the inside of the cover. 3. If incoming voltage is single phase, control panel shall include a variable frequency drive to convert voltage to 3-phase for the motor 4. Enclosures shall be NEMA 4 with disconnect switch. 5. Pushbuttons (interior) for each door shall have one (1) momentary pressure three-button push-button station marked OPEN, CLOSE and STOP. Push button enclosure shall be NEMA 4. 6. Limit switches shall be provided to stop the travel of the door in its fully open or fully closed position. 7. Safety edges: Provide electric safety edges on leading edge of all doors to reverse door upon contact with obstruction. Provide wireless safety edge transmitters with low battery alarm 8. Photo eyes: Provide (1) exterior, jamb mounted, thru-beam type photo eyes, NEMA 4 rated. 9. (Option) Presence Sensor: Provide (1) interior, overhead mounted, presence sensor. FF100-600 SERIES, FOUR-FOLD DOORS 4

10. (Option) Radio controls: Provide one (1) radio receiver and (1) single button remotes per door. Remotes to open and close doors with single button. 11. (Option) Safety Loop Detectors: Provide safety loop detector to reverse or hold the door open when activated. G.C. to coordinate installation of preformed loop with installer prior concrete being poured. 12. (Option) Timer Activation Loop Detectors (fire station applications): Provide pulse on exit type loop detector to activate auto close timer once loop has been activated and cleared, include hand/auto switch to deactivate timer. G.C. to coordinate installation of preformed loop with installer prior to exterior apron being poured. 13. Wiring: Door manufacturer shall supply controls and components only. Electrical contractor shall install controls and furnish and install conduits and wiring for jobsite power and control wiring. PART 3 - EXECUTION 3.1 INSTALLATION A. Install Four-Fold metal doors in strict accordance with the approved drawings by qualified door erection crews. All door openings shall be completely prepared by the general contractor prior to the installation of the doors. Permanent or temporary electric wiring shall be brought to the door opening before installation is started and shall be completed so as not to delay the inspection test. B. Doors shall be set plumb, level, and square, and with all parts properly fastened and mounted. All moving parts shall be tested and adjusted and left in good operating condition. 3.2 ADJUSTING AND CLEANING A. Inspection of the doors and a complete operating test will be made by the installer in the presence of the general contractor or architect as soon as the erection is complete. Any defects noted shall be corrected. After door approval in the above test, the general contractor must assume the responsibility for any damage or rough handling of the doors during construction until the building is turned over to the owner and final inspection is made. B. Clean surfaces and repaint abraded or damaged finished surfaces to match factory-applied finish. END OF SECTION FF100-600 SERIES, FOUR-FOLD DOORS 5