Determination of the sound reduction and sound absorption of a railroad noise barrier

Similar documents
Laboratory measurements of the reduction of transmitted impact sound by floor coverings on a heavyweight reference floor (According to ISO )

Evidence of Performance Joint sound reduction of filling material

LABORATORY MEASUREMENT OF AIRBORNE SOUND INSULATION OF PIR ROOF PANELS (According to ISO )

KINETICS NOISE CONTROL TEST REPORT #AT001110

LABORATORY MEASUREMENTS OF THE SOUND REDUCTION INDEX ROCKWOOL ABLATIVE COATED BATTS

Evidence of Performance Airborne sound insulation of building components

ASTM E 90-09: Laboratory Measurement of Airborne Sound Transmission of Building Partitions and Elements

KINETICS NOISE CONTROL TEST REPORT #AT001021B

KINETICS NOISE CONTROL TEST REPORT #AT001067

Evidence of Performance Joint sound reduction of filling material

Testing Procedure: AS ISO

Classification report Airbourne sound insulation of building elements

THE FRAME RESIDENTIAL DEVELOPMENT, SPORTCITY, MANCHESTER THE CONCRETE CENTRE LTD 1.0 INTRODUCTION...2

TEST REPORT NO

Testing Procedure: AS ISO

KINETICS NOISE CONTROL TEST REPORT # AT001084

KINETICS NOISE CONTROL TEST REPORT #AT001035

Report Number BTC 13236A

Analysis Joint sound insulation of filler materials

Signatures are required on this document for an official laboratory test report. Copies of this document without signatures are for reference only.

Evidence of Performance Joint sound reduction of filling material

Façade sound insulation of residential houses within Hz

Important Notice. QuietRock by PABCO Gypsum Cherry Street Newark, CA

Important Notice. QuietRock by PABCO Gypsum Cherry Street Newark, CA

BELLOTI, S.p.a. Via San Francesco, Cermenate (CO) - ITALY TEST REPORT

Report. Laboratory for Acoustics Determination of the insertion loss or sound power insulation of Arma-Chek Sound Insulation

RIVERBANK ACOUSTICAL LABORATORIES

inter.noise 2000 The 29th International Congress and Exhibition on Noise Control Engineering August 2000, Nice, FRANCE

TEST REPORT. Report Number : / Report Date : 27 / 07 / 2015

RIVERBANK ACOUSTICAL LABORATORIES

RIVERBANK ACOUSTICAL LABORATORIES

NOISE BARRIER AT WELDING WORKPLACE

RIVERBANK ACOUSTICAL LABORATORIES

E R0 ACOUSTICAL PERFORMANCE TEST REPORT ASTM E90. Rendered to: PAC INTERNATIONAL, LLC

C R0 ACOUSTICAL PERFORMANCE TEST REPORT ASTM E 90 AND ASTM E 492. Rendered to. ECORE International. Series/Model: Base 10

E R0 ACOUSTICAL PERFORMANCE TEST REPORT ASTM E 492 AND ASTM E Rendered to REGUPOL AMERICA

White Paper. A guide to the acoustic performance of Smarts Systems Products. Building Regulations Document E Resistance to the passage of sound

CONDUCTED: 26 November 2013 Page 1 of 6

VTT Technical Research Centre of Finland VTT GROUP 2017 Place for a photo (no lines around photo) Mikko Nyman VTT Expert Services Ltd

E R0 ACOUSTICAL PERFORMANCE TEST REPORT ASTM E 90 AND ASTM E 492. Rendered to SENECA RADIANT TECHNOLOGIES

E R0 ACOUSTICAL PERFORMANCE TEST REPORT ASTM E90. Rendered to: GAMCO CORPORATION. Series/Model: CW250

ASTM E 90 SOUND TRANSMISSION LOSS TEST REPORT. Rendered to: THERMA-TRU DOORS. SERIES/MODEL: Slimline. TYPE: 8/0 Sliding Patio Door

KINETICS NOISE CONTROL TEST REPORT #AT001108

Sound Insulation for Glass and Panel

-Letter - Tables 1 and 2 - Figure 1 - Exhibits 1 through 6

Sound Insulation Test Easterton of Duntelchaig, Farr, Inverness, IV2 6AW

IAC Acoustics Noise-Foil Sound Absorption Panels for Industrial Applications. Dan O Brien

CONDUCTED: 26 November 2013 Page 1 of 6

ASTM E 90 SOUND TRANSMISSION LOSS TEST REPORT. Rendered to: MI WINDOWS AND DOORS, LLC. SERIES/MODEL: 1650 Polyvinyl Chloride (PVC)

Rainfall and impact noise measurements on metal roof tiles

ACOUSTICAL TREATMENT OF EMERGENCY POWER GENERATOR. Dr. M.Abd El Gawad Saif

E R0 ACOUSTICAL PERFORMANCE TEST REPORT ASTM E90. Rendered to: THERMA-TRU CORPORATION

600 Series 56 STC. Results Apply to 600 Series; Individual and Pairs. Quentin J. Schrader. Lab Code: /17/2014

Report. Draft. Laboratory for Acoustics

148th MEETING OF THE ACOUSTICAL SOCIETY OF AMERICA November 15-19, 2004 (San Diego, California, USA)

ACOUSTIC DESIGN OF THE AUDITORIUM IN THE CHURCH OF RISPESCIA

FLOOR CEILING ASSEMBLY

TIMBER REFLECTIVE NOISE BARRIER - ACOUSTIC FENCING. Acoustic Barriers. Gramm Barrier Systems Registered in England and Wales No:

Edition October May (always refer to the latest manual as set out on

Delia Chamberlain, Vice President, Kolay Floors Steve Hedback and Joel Esselstrom, SSA Acoustic, LLP

Conducting A Sound Insulation Test

RC CHANNEL ACOUSTIC ASSEMBLY

RIVERBANK ACOUSTICAL LABORATORIES

RIVERBANK ACOUSTICAL LABORATORIES

Hudson Series 200 Acoustic Louvre

H R0 ACOUSTICAL PERFORMANCE TEST REPORT ASTM E 90 AND ASTM E 492. Rendered to AMORIM CORK COMPOSITES

Hudson Series 300 Acoustic Louvre

inter.noise 2000 The 29th International Congress and Exhibition on Noise Control Engineering August 2000, Nice, FRANCE

Acoustic design of industrial spaces. The reduction of noise levels and increase of production

CASE STUDY OF THE SOUND REDUCTION OF VARIOUS RESIDENTIAL GLAZING TREATMENTS

Acoustic properties of green walls: Absorption and insulation

The effect of additional thermal lining on the acoustic performance of a wall

Effective Noise Barrier Design and Specification

Acoustics in wooden buildings Measurements in the Laboratory and in Single Family Houses

Acoustical characterization of the underground chapels of the new Holy Trinity church in the Fatima shrine, Portugal

Proceedings of Meetings on Acoustics

Acoustic Louvres. Product and Technical Data

SWEDISH STANDARD SS

VALIDATION REPORT No

Enhancing Acoustic Performance through the use of Window Shade Fabric White Paper

Solutions for industrial pipe work insulation

CJ Buma. To: Steelform Building Products Inc. Wednesday, 2007 May Avenue Edmonton, AB, T6B 2V2. Attn: Mr.

Fjardaal Smelter Project

IMPACT NOISE TESTING TIMBER FLOORING & ACOUSTIC UNDERLAY TESTING SCHNEID FLOORING AUSTRALIA PTY LTD

Kinetics Noise Control

CGV/RGV. Sound attenuating transfer units

Statutory Order on noise from wind turbines

inter.noise 2000 The 29th International Congress and Exhibition on Noise Control Engineering August 2000, Nice, FRANCE

ABSORPTION PANELS FOR THE BEST POSSIBLE ACOUSTICS

Airborne sound insulation evaluation and flanking path prediction of coupled room

RSIC-1 ACOUSTIC ASSEMBLY

RMF Intercell. NBS Specification 2013 K41

Community and Environmental Noise Measurement

slimlite Double Glazed Units BS EN 1279 Certificate Double Glazed Units

Acoustics Rating of sound insulation in buildings and of building elements. Part 1: Airborne sound insulation

This page was. intentionally. left blank

Freeze-thaw cycling with de-icing salt immersion, EN PAGEL V1/160 (0-16 mm)

J. A. FERREIRA, F. B. DINIZ, A. FERREIRA and P. H. T. ZANNIN

Acoustics and Classrooms BARD MANUFACTURING COMPANY REGISTERED AIA PRESENTER VAUGHAN SMITH

Transcription:

TEST REPORT No. VTT-S-04940-14 October 29, 2014 Determination of the sound reduction and sound absorption of a railroad noise barrier Requested by: Soundim Oy

TEST REPORT No. VTT-S-04940-14 1 (3) Requested by Order Contact person Soundim Oy Pakkaskuja 1 01390 Vantaa Email by 21.10.2014 Jukka Näräkkä / confirmation of order VTT-O-159133-14. VTT Expert Services Ltd Veijo Sivonen P.O. Box 1001, FI-02044 VTT, Finland Tel. + 358 20 722 6985, Fax + 358 20 722 7003 Email: veijo.sionen@vtt.fi Task Determination of the airborne sound insulation and sound absorption of railroad noise barrier Structure of the Photos of the measurements and the structure and details of the noise barrier specimen are show in Appendix 2. Date and place of testing Installation and measuring The sound insulation of the noise barrier was tested 13.10.2014 and sound absorption was tested 10.10.2014 by the personnel of VTT Expert Services Ltd at VTT Expert Services Ltd:s research hall 1. The airborne sound insulation test specimen was installed by VTT Expert Services Ltd:s personnel into the measurement opening (with dimensions 1210 x 1030 mm) between two reverberation rooms. The sound absorption test specimen (with size 3 m x 4 m) was installed client onto the floor of a reverberation room KH 3. The airborne sound reduction index of the specimen was determined by means of two-channel sound pressure level measurement with two fixed sources and moving microphones. The measurement we carried out by Technical Expert Veijo Sivonen. Method and equipment The sound reduction index R was measured in accordance with EN ISO 10140 2:2010 1 in one third octave bands and the single number rating DL R and categorisation was determined in accordance with EN 1793 2 and EN 1793 3 2 and 3. Sound insulation of the barrier was measured specimen area, which was smaller than that 12 m 2 provided by the standard. It can be approximated that the sound reduction index of the smaller specimen is a baud 2 db higher than that of specimen with area of 12 m2. However, this has no effect on the achieved classification.

TEST REPORT No. VTT-S-04940-14 2 (3) Sound absorption and sound absorption coefficients Si in one third octave bands were measured according to standard EN 20352 4. The single number rating DL and categorisation was determined in accordance with EN 1793 1 5. Reverberation room dimensions and measuring equipment are presented in Appendix 3. Results The individual measuring result are presented in Appendix 1. The categorisation of the railroad noise barrier is as follows: Noise barrier Aluminium frame / insulation (Evona 36 kg/m 2 ) / metal cladding Sound insulation Sound absorption DL R db(a) Category DL α Category 30 B3 13 A4 Espoo October 29, 2014 Pekka Sipari Senior Expert Veijo Sivonen Technical Expert VTT Expert Services Ltd. is notified body No. NB 0809. FINAS Finnish Accreditation Service has accredited our laboratory (T001, VTT Expert Services Ltd) to perform the tests mentioned.

TEST REPORT No. VTT-S-04940-14 3 (3) Appendices Appendix 1 Results Appendix 2 Structure of the noise barrier and photos from measurements Appendix 3 Reverberation rooms and equipments Distribution Customer Original Archive Original References [1] EN ISO 10140-2:2010 Acoustics - Measurement of sound insulation in buildings and of building elements - Part 2: Laboratory measurements of airborne sound insulation of building elements 2 EN 1793-2 Road traffic noise reducing devices. Test method for determining the acoustic performance. Intrinsic characteristics of airborne sound insulation 3 EN 1793-3 Road traffic noise reducing devices. Test method for determining the acoustic performance. Normalized traffic noise spectrum 4 EN ISO 354 Acoustics - Measurement of sound absorption in a reverberation room 5 EN 1793-1 Road traffic noise reducing devices. Test method for determining the acoustic performance. Intrinsic characteristics of sound absorption

Sound reduction index, R, db TEST REPORT No. VTT-S-04940-14 APPENDIX 1 1 (2) Results sound insulation Client: Soundim Oy Product identification: Railroad noise barrier Vantaa Aluminium frame / insulation (Evona 36 kg/m2) / metal cladd Test specimen mounted by: VTT Expert services Oy Date of test: 13.10.2014 Areas of test specimen: 1,3 m² Air temp. in the test rooms: 21 C Air humidity in the test rooms: 46 % Source room volume: 102 m³ Receiving room volume: 131 m³ Frequency range acording to the curve of reference values ISO 717-1 0 Frequency One-third f octave Hz db 50 20,9 63 22,5 80 15,4 100 13,8 125 18,0 160 20,0 200 23,3 250 27,4 315 29,7 400 31,5 500 34,3 630 35,9 800 37,2 1000 38,0 1250 39,6 1600 39,7 2000 39,4 2500 37,4 70 60 50 40 30 20 3150 37,9 4000 40,5 5000 44,9 10 63 125 250 500 1000 2000 4000 Frequency f, Hz Rating according to ISO 717-1: According to EN1793-2 and EN1793-3: R w (C ;C tr ) = 36 (-2 ; -6) db; DL R = 30 db(a) CATEGORY: B3 Evaluation based on laboratory measurement results obtained by an engineering method

Absorption coefficient s (ISO 354:1985) TEST REPORT No. VTT-S-04940-14 APPENDIX 1 2 (2) Determination and classification of sound absorption Customer: Soundim Oy Pakkaskuja 1, 01390 Vantaa Reverberation room: Order: Jukka Näräkkä Volume : 201 m 3 Surf. area: 209 m 2 Test site: VTT/TH1 Otaniemi Sample: 12,1 m 2 Date of test: 10.10.2014 Temperature and relative humitidy: Commission: Determination and classification of absorption coefficient Empty 21 C 59 % (ISO 354-2003, E and EN 1793-1:1998) Sample 21 C 59 % Specimen: Area: Mass: Installation: Railroad noise barrier: aluminium frame / insulation (Evona 36 kg/m2) / metal cladding 12,1,8 m2 60 kg/m2 Sample on the floor RESULTS: 1,2 1 0,8 0,6 0,4 0,2 0 100 200 400 800 1600 3150 Frequency (Hz) Freq. T 1 T 2 S (Hz) (s) (s) 100 4,86 2,27 0,63 125 5,21 2,47 0,57 160 5,43 2,12 0,77 200 5,10 1,95 0,85 250 5,25 1,90 0,90 315 5,06 1,93 0,86 400 4,37 1,80 0,87 500 4,46 1,74 0,94 630 4,79 1,73 0,99 800 5,02 1,73 1,01 1000 5,04 1,77 0,98 1250 4,73 1,74 0,97 1600 4,23 1,66 0,98 2000 3,83 1,59 0,98 2500 3,51 1,53 0,99 3150 3,03 1,49 0,91 4000 2,57 1,42 0,84 5000 2,15 1,31 0,80 DL = 13 Class A4

TEST REPORT No. VTT-S-04940-14 APPENDIX 2 1 (3) Structure of the noise barrier and photos from measurement

TEST REPORT No. VTT-S-04940-14 APPENDIX 2 2 (3)

TEST REPORT No. VTT-S-04940-14 APPENDIX 2 3 (3) Photo 1. Airborne sound measurement Photo 2. Absorption measurement

TEST REPORT No. VTT-S-04940-14 APPENDIX 3 1 (1) Measuring equipment and reverberation room dimensions / Sound insulation Measuring equipment Name Serial No. Condenser microphone B&K (Brüel&Kjær) 4134 2415044 Condenser microphone B&K (Brüel&Kjær) 4134 2527717 Microphone preamplifier B&K 2639 2025241 Microphone preamplifier B&K 2639 2554550 Rotating microphone boom B&K 3923 1678216 Rotating microphone boom B&K 3923 2630663 Power amplifier Yamaha MX-1000 Loudspeakers Sinmarc V121L Real-time analyser Norsonic 830 12717 Sound calibrator B&K 4228 1704462 Reveberation room dimensions Floor Height Volume Source room KH1 4.7 m x 5.8 m 3.7 m 102 m 3 Receving room KH2 5.0 m x 6.5 m 4.0 m 131 m 3 Thickness of the concrete walls, floors and ceilings of the reverberation rooms is 0.25 m Measuring equipment and reverberation room dimensions / Sound absorption Measuring equipment Name Serial No. Condenser microphone B&K (Brüel&Kjær) 4134 2527717 Microphone preamplifier B&K 2660 2554550 Rotating microphone boom B&K 3923 2630663 Power amplifier Peavey PV 2600 Loudspeakers Sinmarc V121L Real-time analyser Norsonic 830 12717 Sound calibrator B&K 4228 1704462 Reveberation room dimensions Floor Height Volume Reveberation room KH3 5.95 m x 7.20 m 4.70 m 201 m³ Thickness of the concrete walls, floors and ceilings of the reverberation rooms is 0.25 m