HID Real-Time PCR Analysis Software v1.1

Similar documents
Validation Using SDS Software Version on the Applied Biosystems 7500 Real-Time PCR System and the ABI PRISM 7000 Sequence Detection System

Applied Biosystems 7500 Fast Real-Time PCR System

Protocol for Creating Custom RT and Preamplification Pools using TaqMan MicroRNA Assays

User Bulletin. Veriti 96-Well Thermal Cycler AmpFlSTR Kit Validation. Overview

TaqMan Protein Assays Probe Development

Applied Biosystems TaqMan Array Microfluidic Cards

Quantifiler Human DNA Quantification Kit Quantifiler Y Human Male DNA Quantification Kit

User Bulletin. ABI PRISM 7000 Sequence Detection System DRAFT. SUBJECT: Software Upgrade from Version 1.0 to 1.1. Version 1.

SUBJECT: System Software Patch Provides Support for Fast SYBR Green Master Mix and RNA-to-C T

Applied Biosystems 7900HT Fast Real-Time PCR System. Performing Fast Gene Quantitation with 384-Well Plates DRAFT

Procedure for DNA Quantitation with Quantifiler Duo

PCR SYSTEMS. a new era in high-productivity qpcr. Applied Biosystems ViiA 7 Real-Time PCR System

Applied Biosystems 7500 Fast, 7500 and 7300 Real-Time PCR Systems

Same TaqMan Assay quality, new format

Perform an HRM Methylation Study

RapidFinder Quant Multi-Meat Set

Data Analysis on the ABI PRISM 7700 Sequence Detection System: Setting Baselines and Thresholds. Overview. Data Analysis Tutorial

Protocol. Path-ID Multiplex One-Step RT-PCR Kit Protocol TaqMan probe-based multiplex one-step real-time RT-PCR detection of RNA targets

AccuSEQ Real-Time PCR Detection Software

Multiplex RT for TaqMan Array Human MicroRNA Panel

Plexor HY System for the Applied Biosystems 7500 and 7500 FAST Real-Time PCR Systems

Georgia Bureau of Investigation - Division of Forensic Sciences DNA Procedures Manual DNA QUANTIFICATION USING QUANTIFILER HUMAN / Y HUMAN MALE KIT

ReadMe Software v2.0.1 For Applied Biosystems 7500 and 7500 Fast Real-Time PCR Systems

TaqMan Bacillus anthracis Detection Kit

Tali Viability Kit Dead Cell Green

TaqMan Pseudomonas aeruginosa Detection Kit

User Bulletin. Applied Biosystems 3400 DNA Synthesizer. New Features in 3400 DNA Synthesizer Firmware v In This User Bulletin

Relative Quantification (Mono-Color) Unknown samples (purified total RNA, mrna or cdna or genomic DNA)

TaqMan OpenArray MicroRNA Panels

RapidFinder Sheep ID Kit

NRAS Codon 61 Mutation Analysis Reagents

Custom dye calibration for StepOne and StepOnePlus Real-Time PCR Systems

TaqMan GMO Maize Quantification Kit

Investigator Quantiplex HYres Kit

NRAS Mutation Analysis Reagents (Codons 12 and 13)

PrepSEQ Residual DNA Sample Preparation Kit

Data Quality Worth Sharing

quantitate host cell DNA with high sensitivity and throughput resdnaseq Host Cell DNA Quantitation Systems: CHO, E.

Applied Biosystems Real-Time PCR Rapid Assay Development Guidelines

Dynabeads Antibody Coupling Kit

M. tuberculosis_mpb64/is61 10 genesig Standard Kit

TaqMan Cytokine Gene Expression Plate I Protocol

Silencer Select Pre-designed sirna Silencer Select Validated sirna Silencer Select Custom Designed sirna Custom Select sirna

AmpFlSTR NGM SElect PCR Amplification Kit. User Guide

User Bulletin #2. ABI PRISM 7700 Sequence Detection System. Introduction. Contents. December 11, 1997

AmpFlSTR NGM PCR Amplification Kit

Genomic DNA quantification assay. Quantification of genomic DNA by real-time PCR

User Manual. NGS Library qpcr Quantification Kit (Illumina compatible)

TQ RXN 2X Q-PCR Master Mix (SYBR, no ROX) 1 ml x 2 TQ RXN 2X Q-PCR Master Mix (SYBR, no ROX) 1 ml x 5

Introducing a new generation of affordable choices from the leader in real-time PCR. Applied Biosystems 7500 Fast Real-Time PCR System

TaqMan PreAmp Master Mix Kit. Protocol

Setting Up a Multiplex (two probe) Real Time 5 Nuclease Reaction on the ABI PRISM 7700 Sequence Detection System

Real-Time PCR ABI Prism 7500 (PSC 563, NSC 338) Real-Time PCR StepOne (PSC 563)

KAPA Library Quantification Kit Ion Torrent Platforms

Reliable. answers, significant savings. Applied Biosystems QuantStudio 5 Real-Time PCR System for Human Identification

Eureka Genotyping Assay

M. tuberculosis_mpb64/is611. genesig Advanced Kit. 150 tests. Primerdesign Ltd. For general laboratory and research use only

Validation of a Multiplexed System for Quantification of Human DNA and Human Male DNA and Detection of PCR Inhibitors in Biological Samples

APPLICATION NOTE. The QuantStudio 12K Flex Real-Time PCR System

Applied Biosystems QuantStudio 12K Flex Real-Time PCR System

Bacteriophage MS2. genesig Standard Kit. Phage MS2 genome. 150 tests. Primerdesign Ltd. For general laboratory and research use only

Accurately and reproducibly quantify as little as 20 fg of human DNA using real-time PCR.

Troubleshooting Chemistry and Assay Runs

Real-Time PCR Validations

myt KRAS qpcr primers for detection of seven human KRAS codon 12/13 mutations:

SYBR Green Realtime PCR Master Mix

KAPA Human Genomic DNA Quantification and QC Kit

HID Validation: The 3500 Series Genetic Analyzers

DNA Genotyping from Human FFPE Samples Reliable and Reproducible

Acinetobacter baumannii

Evaluation with RNA ScreenTape Assays

Mycobacterium Tuberculosis

Intracellular ph (phi) Detection

Gadus morhua Cod speciation kit. genesig Easy Kit. for use on the genesig q reactions. Primerdesign Ltd

Human Herpes Virus 1 (Herpes simplex type 1)

AccuSEQ v2.1 Real-Time PCR Detection and Analysis Software

TaqPath ProAmp Master Mixes

Phosphate buffered saline (PBS) for washing the cells TE buffer (nuclease-free) ph 7.5 for resuspending the SingleShot RNA control template

TaqMan Bacillus anthracis Detection Kit

Human Papillomavirus 16

Syphacia obvelata. genesig Standard Kit. 28S ribosomal RNA. 150 tests. Primerdesign Ltd. For general laboratory and research use only

Epstein Barr Virus (Human Herpes virus 4)

Oncomine cfdna Assays Part III: Variant Analysis

Single Cell 3 Reagent Kits v2 Quick Reference Cards

Internal DNA extraction control

Relative Quantification Applied Biosystems 7300/7500/7500 Fast Real-Time PCR System

BuccalQuick. Buccal Cell DNA extraction. User Manual V1.2

Stratagene QPCR Mouse Reference Total RNA

Dengue Virus subtypes 1,2 3 and 4

Acinetobacter baumannii

Arachis hypogaea A.hypogaea. genesig Allergen detection Kit. 100 tests. Primerdesign Ltd. For general laboratory and research use only

BigDye Direct Cycle Sequencing Kit

The Seed Health Toolbox II. Molecular Seed Testing Methods and Processes: What are the sources of variability?

SCIEX Anion Analysis Kit For P/ACE MDQ and P/ACE MDQ plus Capillary Electrophoresis Systems. Instruction Guide

Application Note Detecting low copy numbers. Introduction. Methods A08-005B

Trichomonas vaginalis

Acinetobacter baumannii

Helicobacter pylori. genesig Standard Kit. RNA polymerase beta-subunit (rpob) gene. 150 tests. Primerdesign Ltd

Enterococcus faecium. genesig Standard Kit. groes heat shock protein. 150 tests. Primerdesign Ltd. For general laboratory and research use only

Single Cell 3 Reagent Kits v2 Quick Reference Cards

Transcription:

HID Real-Time PCR Analysis Software v1.1 USER BULLETIN NOVEMBER 2010 SUBJECT: Validation and new features In this user bulletin This user bulletin covers: Validation........................................................... 2 1 Materials and methods.............................................. 2 2 Experimental setup................................................. 3 3 Data collection..................................................... 4 4 Data analysis...................................................... 4 5 Results........................................................... 5 6 Discussion........................................................ 10 7 Conclusions...................................................... 11 8 References....................................................... 11 New features of v1.1 software......................................... 12 Overview The HID Real-Time PCR Analysis Software v1.1 was designed specifically for the 7500 Real-Time PCR System and for the Quantifiler Human, Quantifiler Y Human Male, and Quantifiler Duo DNA Quantification Kits. Quantifiler -specific templates and quality flags, as well as STR reaction and dilution calculation tools, enable streamlined data and sample assessment within the software. New features of the HID Real-Time PCR Analysis Software v1.1 include streamlined sample entry, enhanced reporting and export capability, and improved data analysis tools. Validation consisted of the experiments listed below, comparing Quantifiler Human, Y Human Male, and Duo kit data collected and analyzed with the HID Real-Time PCR Analysis Software v1.1 to data collected and analyzed using the HID Real-Time PCR Analysis Software v1.0. The data generated by the validation experiments demonstrates that the HID Real- Time PCR Analysis Software v1.1 is reliable and reproducible in performing HID Quantifiler kit assays. Our experiments with the kit demonstrated some difference between software versions C T values and quantity values for the in Quantifiler Duo kit, and also in C T values for the Quantifiler Human and Y Human Male kit. However, this variability could be a result of factors such as instrument, assay setup, or time between assay runs. Validation studies performed Precision and Accuracy Reproducibility and Sensitivity

Validation Validation 1 Materials and methods 1.1 Reagents To minimize variation due to hand pipetting and lot-to-lot differences, the following setup procedures were employed throughout the study. One lot of the Quantifiler Human, Y Human Male, and Duo kits was used for all validation studies. A master mix consisting of the primer set and PCR reaction buffer was made daily for all of the plates run on that day. A master mix of each sample dilution was prepared before pipetting into the plate wells. Quantifiler Duo kit For the precision and accuracy study, 12 replicates of the eight serial dilutions of standards, ranging from 23 pg/µl to 50 ng/µl, were prepared and run with each software version and instrument for the Quantifiler Duo kit only. The reproducibility and sensitivity study used standard DNA sample 007 in these concentrations: 10, 5, 2.5, 1.25, 0.625, 0.312, 0.156, and 0.078 ng/µl. Quantifiler Human and Male kits A sensitivity study compared results of the new Quantifiler Human and Y Human Male (hybrid) plate assay using both versions of the software. The samples on the hybrid plate consisted of replicate standard curve dilution series for each kit as well as four replicate serial dilutions of standard control DNA 007 in these concentrations: 10, 5, 2.5, 1.25, 0.625, 0.312, 0.156, and 0.078 ng/µl. Note: For all validation studies, identical sample dilutions were prepared and analyzed with each software version. 1.2 Instruments Two Applied Biosystems 7500 Real-Time PCR System instruments with thermocycler firmware G2.10 were used for the validation. Each 7500 instrument used for the validation was connected to two computers, one with each version of the software (v 1.0 and v1.1). The setup of the computer with v1.1 tested both the upgrade pathway and fresh installation for HID Real-Time PCR Analysis Software v1.1. After software installation, each instrument was calibrated using standard protocols to run the Regions of Interest (ROI), background, optical, and pure dye calibrations, in addition to the TaqMan RNase P Instrument Verification Plate with both HID Real-Time PCR Analysis Software v1.0 and v1.1. 2 HID Real-Time PCR Analysis Software v1.1 User Bulletin

2 Experimental setup 2 Experimental setup 2.1 Quantifiler Duo kit precision and accuracy study Eight serially diluted samples prepared from the Quantifiler Duo kit stock standard were analyzed. Figure 1 shows the plate setup for the Quantifiler Duo kit. Each of the eight standard dilutions was run 12 times on each plate, then C T values were compared. In addition, six standard curves were generated per plate for slope, Y-intercept, and R 2 comparisons. Figure 1 Precision and accuracy plate layout for Quantifiler Duo kit A B C D E F G H 1 2 3 4 5 6 7 8 9 10 11 12 Standard DNA dilution 50 ng/µl 16.7 ng/µl 5.56 ng/µl 1.85 ng/µl 0.62 ng/µl 0.21 ng/µl 0.068 ng/µl 0.023 ng/µl 2.2 Quantifiler Duo, Human, and Y Human Male kit reproducibility and sensitivity study Control DNA sample 007 was diluted and tested, using the Quantifiler Duo, Human, and Y Human Male kits and each software version. A single standard curve dilution series was prepared and used to test each software version with the diluted control DNA samples. As Figure 2 and Figure 3 show, eight dilutions of sample DNA 007 were prepared in these concentrations: 10, 5, 2.5, 1.25, 0.625, 0.312, 0.156, and 0.078 ng/µl. C T values of each sample concentration and each calculated quantity were compared between the two software versions tested (v1.0 and v1.1). Figure 2 Reproducibility and sensitivity plate layout for Quantifiler Duo samples A B C D E F G H 1 2 3 4 5 6 7 8 9 10 11 12 Standard DNA dilution 50 ng/µl 16.7 ng/µl 5.56 ng/µl 1.85 ng/µl 0.62 ng/µl 0.21 ng/µl 0.068 ng/µl 0.023 ng/µl 007 Sample DNA dilution 10 ng/µl 5 ng/µl 2.5 ng/µl 1.25 ng/µl 0.625 ng/µl 0.312 ng/µl 0.156 ng/µl 0.078 ng/µl HID Real-Time PCR Analysis Software v1.1 User Bulletin 3

3 Data collection Figure 3 Reproducibility and sensitivity plate layout for Quantifiler Human and Y Human Male samples A B C D E F G H 1 2 3 4 5 6 7 8 9 10 11 12 Standard DNA dilution 50 ng/µl 16.7 ng/µl 5.56 ng/µl 1.85 ng/µl 0.62 ng/µl 0.21 ng/µl 0.068 ng/µl 0.023 ng/µl Sample DNA dilution 10 ng/µl 5 ng/µl 2.5 ng/µl 1.25 ng/µl 0.625 ng/µl 0.312 ng/µl 0.156 ng/µl 0.078 ng/µl Quantifiler Human Quantifiler Y Human Male 2.3 User interface evaluation The HID Real-Time PCR Analysis Software v1.1 was tested to verify the accuracy of the HID-specific quality flags as well as the plate setup and run monitoring. The HID flags were analyzed to determine if samples were flagged correctly given the thresholds set. Plate setup and performance were evaluated during the course of data collection and setup. 3 Data collection Run methods for each Quantifiler kit were configured as outlined in the respective Quantifiler kit user manuals. Although there is no 9600 Emulation mode checkbox in HID Real-Time PCR Analysis Software v1.1 or v1.0, a calculated ramp-up of 64% and ramp-down of 100% was used in all validation experiments to mimic the 9600 Emulation mode in SDS v1.2.3. 4 Data analysis All runs were analyzed using the manual analysis mode in each software version, with the baseline set to start at cycle 3 and end at cycle 15. The manual C T threshold was set to 0.2. 4 HID Real-Time PCR Analysis Software v1.1 User Bulletin

5 Results 5 Results 5.1 Precision and accuracy For the precision and accuracy studies, the following values were determined: Average C T IPC C T values Slope Y-Intercept R 2 C T Results Figure 4 Mean C T values for the Quantifiler Duo kit with human and Internal PCR Control (IPC) targets generated by each software version at each DNA standard concentration. Error bars indicate standard deviations. Overall, the two versions of the software produced data that was highly similar or identical. Statistical analysis showed no significant difference between the Duo Human and Duo Male targets (data not shown). Statistical analysis of the IPC C T values demonstrated a statistically significant difference between data produced by the two versions of the software. However, the mean difference was 0.14 C T between software versions, only slightly more than the mean difference of 0.12 C T between instruments. HID Real-Time PCR Analysis Software v1.1 User Bulletin 5

5 Results Standard curve metrics Figure 5 shows the average slope and Y-intercept values for the Quantifiler Duo kit generated by each software version. Differences in slope, Y-intercept, and R 2 standard curve metrics between the software versions were statistically insignificant (R 2 data not shown). Figure 5 Mean slope and Y-intercept values for the Quantifiler Duo kit generated by each software version 5.2 Reproducibility and sensitivity Sensitivity differed slightly between the two software versions in studies using the 007 DNA standard with each of the Quantifiler kits. Quantifiler Duo kit C T values for the human target in the 007 dilution series indicated a small though statistically significant mean difference of 0.05 C T between the software versions in studies with the Quantifiler Duo kit (data not shown). Mean C T values for the male target did not differ significantly between the software versions. As shown in Figure 6 and Figure 7, human and male target quantities calculated with HID Real-Time PCR Analysis Software v1.1 differed slightly (0.49 ng/µl for the human target; 0.54 ng/µl for the male target). Because the mean C T values were nearly identical, we attribute the difference in target quantities to the differences in the standard curves. No statistical difference was observed in the IPC C T values of the 007 dilution series. 6 HID Real-Time PCR Analysis Software v1.1 User Bulletin

5 Results Quantifiler Human and Male kits We observed more variable sensitivity between the software versions in studies with the Quantifiler Human and Y Human Male kit. As shown in Figure 8 and Figure 9, the HID Real-Time PCR Analysis Software v1.1 reported lower mean C T values and higher calculated quantities with the Quantifiler Human kit, and higher mean C T values and lower calculated quantities with the Quantifiler Y Human Male kit. In addition, v1.1 of the software reported a higher IPC C T value than v1.0. Figure 6 Mean quantities of human target DNA determined with the Quantifiler Duo kit by each version of the software. Error bars indicate standard deviations. HID Real-Time PCR Analysis Software v1.1 User Bulletin 7

5 Results Figure 7 Mean quantities of male target DNA determined with the Quantifiler Duo kit by each version of the software. Error bars indicate standard deviations. Figure 8 Mean C T of human target DNA determined with the Quantifiler Human kit by each version of the software. Error bars indicate standard deviations. 8 HID Real-Time PCR Analysis Software v1.1 User Bulletin

5 Results Figure 9 Mean C T of human male target DNA determined with the Quantifiler Y Human Male kit by each version of the software. Error bars indicate standard deviations. HID Real-Time PCR Analysis Software v1.1 User Bulletin 9

6 Discussion 6 Discussion 6.1 Quantifiler Duo kit: precision and accuracy 6.2 Quantifiler Duo, Human, and Male kits: sensitivity The data generated with the Quantifiler Duo kit did not demonstrate statistically significant differences between v1.0 and v1.1 for the human and the male targets. The maximum mean C T difference observed was 0.21 C T for both the human (50 ng/µl standard) and male (0.023 ng/µl standard) targets. The mean difference in IPC C T values was 0.14 C T, which is small but statistically significant. A similar difference between the two 7500 Real-Time PCR Systems used in the study suggests that the instruments might have introduced variability. Statistical analysis of the standard curve metrics (slope, Y-intercept, and R 2 ) did not demonstrate statistically significant differences between the two versions of the software. Quantifiler Duo kit C T values for the 007 dilution series showed a small but statistically significant difference for the human target only (0.05 C T ), while the male and IPC targets showed no significant difference in these C T values. Calculated mean quantities showed more variability between versions of the software for both human (0.49 ng/µl) and male (0.54 ng/µl) targets. We observed a similar difference between instruments, suggesting that both the instruments and the individual standard curves introduced variability. Quantifiler Human and Y Human Male kits Sensitivity differed more between software versions in studies using the Quantifiler Human and Y Human Male kits. The HID Real-Time PCR Analysis Software v1.1 reported values that were 0.7 C T less for the Human kit, and 0.4 C T more for the Y Human Male kit, than the HID Real-Time PCR Analysis Software v1.0. As a result, mean differences in quantity calculations were 0.33 ng/µl for the Quantifiler Human kit and 0.16 ng/µl for the Quantifiler Y Human Male kit. Re-analysis of raw data from each run with each version of the software produced identical C T values, demonstrating that there is no difference between the C T algorithms used by the two versions of the software. The differences in data generated by v1.0 and v1.1 may be attributable to small differences in plate preparation and sample run during different experiments. 10 HID Real-Time PCR Analysis Software v1.1 User Bulletin

7 Conclusions 7 Conclusions This validation study demonstrated the reliability and reproducibility of the new HID Real-Time PCR Analysis Software v1.1 for performing quantitation using the Quantifiler Human, Quantifiler Y Human Male, and Quantifiler Duo DNA quantification kits and the 7500 Real-Time PCR System. HID Real-Time PCR Software v1.1 generated C T values and standard curve metrics (slope, Y-intercept, and R 2 values) with the Quantifiler Duo kit that were nearly identical to data generated with HID Real-Time PCR Analysis Software v1.0. Quantity values demonstrate a statistically significant difference, but that difference is attributable to differences in the individual standard curves. Quantifiler Human and Y Human Male kit assay results demonstrated some variability between the software versions (v1.0 and v1.1). Further re-analysis of the raw data with each software version produced identical results. Thus, the variability could be a result of factors such as instrument, assay setup, or time between assay runs. All workflows, run methods, HID quality flags, and dilution calculations were defined and utilized identically for each version of the software. 8 References Federal Bureau of Investigation (2000) Quality assurance standards for forensic DNA testing laboratories, Forensic Science Communications [Online]. (July 2000). Available at: http://www.fbi.gov/hq/lab/fsc/backissu/july2000/ codis2a.htm Scientific Working Group on DNA Analysis Methods (SWGDAM) Revised validation guidelines (approved July 2003). Available at:http://www.fbi.gov/hq/ lab/fsc/backissu/july2000/codis2a.htm Applied Biosystems HID Real-Time PCR Analysis Software v1.1 Getting Started Guide (PN 4401644). Applied Biosystems Quantifiler Kits User Bulletin, Validation Using SDS Software Version 1.2.3 on the Applied Biosystems 7500 Real-Time PCR System and the ABI PRISM 7000 Sequence Detection System (PN 4374659). Applied Biosystems Quantifiler Kits User s Manual (PN 4344790). Applied Biosystems Quantifiler Duo DNA Quantification Kit User s Manual (PN 4391294). Applied Biosystems HID Real-Time PCR Analysis Software v1.0 Validation User Bulletin (PN 4401643). HID Real-Time PCR Analysis Software v1.1 User Bulletin 11

New features of v1.1 software New features of v1.1 software Software function New feature User interface Hybrid template access Adding a sample to a well Start-up preferences Default settings Plate layout view Show in wells screen Analysis tools Omitting targets Selecting samples Sorting results The Hybrid (Quantifiler Human and Male) plate option is available as a template on the home screen. Double-clicking the well in the plate layout view opens the Add Sample dialog box, so you can add a sample without returning to the Define Samples area (See Figure 10). You can specify more start-up preferences. Save settings as defaults in the plate layout view in addition to the well table view, and also in the Show in Wells screen. The new default settings, and column arrangement in the well table view, persist each time you open the software. Setup and analysis settings can be different. Omit either the human or male target from the standard curve during standard curve analysis in the Quantifiler Duo assay by selecting the well of interest, then omitting the target (See Figure 11). Select all unknown samples for STR kit selection and dilution calculations with one click. You can sort data by column or row in the Results table. The exported data file shows data sorted the way you chose for the Results table. Exporting and reporting options Exporting.jpg of standard Includes slope, Y-intercept, and R 2. curve Standard curve The standard curve includes data points for standard samples only. Well selection You can export and print results for specific wells, or for all wells. Results table Printed Results Table contains all report data (in v1.0, reports contained a Report Table and Report Summary, each with some of the data). Long sample names A sample name in a report can be up to 100 characters long. 12 HID Real-Time PCR Analysis Software v1.1 User Bulletin

New features of v1.1 software Figure 10 One-step sample addition and well assignment Figure 11 Omitting a single target of the Quantifiler Duo kit assay HID Real-Time PCR Analysis Software v1.1 User Bulletin 13

For Research Use Only. Not intended for any animal or human therapeutic or diagnostic use. Information in this document is subject to change without notice. Life Technologies Corporation assumes no responsibility for any errors that may appear in this document. APPLIED BIOSYSTEMS DISCLAIMS ALL WARRANTIES WITH RESPECT TO THIS DOCUMENT, EXPRESSED OR IMPLIED, INCLUDING BUT NOT LIMITED TO THOSE OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. IN NO EVENT SHALL APPLIED BIOSYSTEMS BE LIABLE, WHETHER IN CONTRACT, TORT, WARRANTY, OR UNDER ANY STATUTE OR ON ANY OTHER BASIS FOR SPECIAL, INCIDENTAL, INDIRECT, PUNITIVE, MULTIPLE OR CONSEQUENTIAL DAMAGES IN CONNECTION WITH OR ARISING FROM THIS DOCUMENT, INCLUDING BUT NOT LIMITED TO THE USE THEREOF. Limited Use Label License: Product Disclaimer The products in this Bulletin may be covered by one or more Limited Use Label License(s). Please refer to the respective product documentation or the Applied Biosystems website under www.appliedbiosystems.com for the comprehensive license information. By use of these products, the purchaser accepts the terms and conditions of all applicable Limited Use Label Licenses. These products are sold for research use only, and are not intended for human or animal diagnostic or therapeutic uses unless otherwise specifically indicated in the applicable product documentation or the respective Limited Use Label License(s). For information on obtaining additional rights, please contact outlicensing@lifetech.com outlicensing@lifetech.com or Out Licensing, Life Technologies, 5791 Van Allen Way, Carlsbad, California 92008. Purchase of this software product alone does not imply any license under any process, instrument or other apparatus, system, composition, reagent or kit rights under owned or otherwise controlled by Life Technologies, either expressly, or by estoppel. 2010 Life Technologies Corporation. All rights reserved. The trademarks mentioned herein are the property of Life Technologies Corporation or their respective owners. TaqMan is a registered trademark of Roche Molecular Systems, Inc. Part Number 4460964 Rev. A 11/2010 Headquarters 5791 Van Allen Way Carlsbad, CA 92008 USA Phone 760.603.7200 www.lifetechnologies.com Technical Resources and Support For the latest technical resources and support information for all locations, please refer to our Web site at www.appliedbiosystems.com