Agilent 4200 Microwave Plasma-Atomic Emission Spectrometer CHANGE IS IN THE AIR

Similar documents
Runs On Air. AGILENT 4100 MICROWAVE PLASMA ATOMIC EMISSION SPECTROMETER

Agilent 5100 ICP-OES DUAL VIEW ICP-OES MINUS THE WAIT

Common Challenges facing Laboratories doing Elemental Analysis Today

Analysis of steel and its alloys using the GB/T standard and an Agilent 5100 ICP-OES in dual view mode

The Agilent Atomic Spectroscopy portfolio for Environmental applications AA, MP-AES, ICP-OES, ICP-MS & ICP-QQQ

icap 7000 Plus Series ICP-OES Streamlined performance and ultra-low ICP-OES detection limits for routine laboratories

Agilent 200 Series AA Systems AGILENT ATOMIC ABSORPTION SPECTROMETERS

DETERMINATION OF ELEMENTS IN DRINKING WATER AS PER BUREAU OF INDIAN STANDARDS 10500, & USING THE AGILENT 5100 ICP-OES

Agilent Resources for Workflow Compliance MEASURING ELEMENTAL IMPURITIES IN PHARMACEUTICAL MATERIALS

ICP Expert software. Technical Overview. Introduction

ICP-OES. Varian Vista-MPX CCD Simultaneous ICP-OES

Increase your lab ROI. Operating cost analysis Resource requirements

Thermo Scientific icap 7000 Plus Series ICP-OES. Gain more power. experience more performance

AMAZINGLY CAPABLE REMARKABLY AFFORDABLE. Avio 200 ICP Optical Emission Spectrometer. For research use only. Not for use in diagnostic procedures.

Agilent 5100 ICP-OES DUAL VIEW ICP-OES MINUS THE WAIT

Sprint analysis of lubricating oils using the Thermo Scientific icap 7600 ICP-OES

Agilent 720/725 ICP-OES RELIABLE. PRODUCTIVE. ROBUST.

Agilent 7820A GC System THE EASY CHOICE FOR ROUTINE ANALYSES

Analysis of Environmental Samples with the Agilent 730-ES Following US EPA Guidelines

Analysis of Stainless Steel by Dual View Inductively Coupled Plasma Spectrometry

PinAAcle 500. Flame Atomic Absorption Spectrometer

SMS 100 MERCURY ANALYZER SMS 100. Mercury analysis directly on solid samples from the undisputed leader in Atomic Spectroscopy

The Determination of Trace Elements in Stainless Steel by Forked Platform GFAAS

Thermo Scientific icap 7000 Series ICP-OES. Low cost ICP-OES analysis high quality data

Flame Atomic Absorption Spectrometer (FAAS) Brand : PERKINALMER Model : PinAAcle 900T Custodian : PRADUP MESAWAT SOOKRUTHAI WONGSUBIN

High matrix tolerance of the Thermo Scientific icap 7000 Plus Series ICP-OES with the radial Ceramic D-Torch and the sheath gas adaptor

Composition Analysis of Animal Feed by HR ICP-OES

High performance radio frequency generator technology for the Thermo Scientific icap 7000 Plus Series ICP-OES

Trace Metals in Waters by GFAAS, in Accordance with U.S. EPA and Health Canada Requirements

Agilent 7693A Series Automatic Liquid Sampler. Inject new performance into your gas chromotography

Avio 200 ICP-OES Flat Plate

PinAAcle 900 AA Flame AA

easy. HPLC has never been so Agilent 1120 Compact LC Our measure is your success.

PinAAcle 900 Series. Atomic Absorption Spectrometers

Agilent 2200 TapeStation System ACCELERATE YOUR SAMPLE QC WITH CONFIDENCE

Agilent 7693A Series Automatic Liquid Sampler INJECT NEW PERFORMANCE INTO YOUR GAS CHROMATOGRAPHY

US EPA Method using the Thermo Scientific icap 7600 ICP-OES Duo

Agilent 7693A Series Automatic Liquid Sampler INJECT NEW PERFORMANCE INTO YOUR GAS CHROMATOGRAPHY

The image part with relationship ID rid4 was not found in the file. Welcome

Agilent InfinityLab LC/MSD Series EXTEND THE BOUNDARIES OF YOUR ANALYSIS

STUDY OF ELEMENT FINGERPRINTING IN GOLD DORÉ BY GLOW DISCHARGE MASS SPECTROMETRY

Thermo Scientific icap 6000 Series ICP Emission Spectrometer

Agilent 8355 Sulfur Chemiluminescence Detector REIMAGINED. REDESIGNED.

Accuracy and Precision. Dilution Error in Error in Factor Accuracy Precision 200 <2% <2%

EU Water Analysis Using the Thermo Scientific icap 7400 ICP-OES Duo

The Determination of Trace Elements in Waters using the US EPA Method and the Thermo Scientific icap 6500 ICP-OES (Duo)

Thermo Scientific icap RQ ICP-MS. Simplicity, productivity and robustness for routine labs

IR READY TO GO. Spectrum Two FT-IR Spectroscopy

World-leading LC/MS/MS technology for quantitation and identification API LC/MS/MS System

Analysis of Trace Metals in Surface and Bottled Water with the Optima 7300 DV ICP-OES

Assaying and Analysis Choices in Practice

HIGHER IMPACT LC/MS DIAGNOSTICS AGILENT IN VITRO DIAGNOSTIC MEDICAL DEVICES FOR CLINICAL LABORATORIES

// XPLORER-NS. Full range Total Nitrogen, Total Sulfur instrument for the modern Laboratory.

NovaWAVE. A new category of Automated Microwave Digestion

TurboMatrix. Thermal Desorption Solutions

Utilizing Glow Discharge in Optical Emission Spectroscopy

Agilent 6400 Series Triple Quadrupole LC/MS. Breakthrough sensitivity now routine for your lab

TANGO. ANALYSIS TO GO. Innovation with Integrity. The next generation FT-NIR spectrometer. FT-NIR

Agilent OpenLAB Chromatography Data System IT S TIME TO ACHIEVE MORE

Perkin Elmer HGA-600/ HGA-700 Graphite Furnaces

PMI-MASTER Compact. Cost-effective, rugged and precise mobile metal analyser. Routine analysis at entry level. Easy and fast testing

Sorting and Drying Code Price Unit. Sorting and Boxing of Samples, received as pulps SORTBOX 0.00 Sample

The next generation FT-NIR spectrometer. Innovation with Integrity FT-NIR

The Determination of Toxic Metals in Waters and Wastes by Furnace Atomic Absorption

Analysis of 14 Trace Elements in Stainless Steel

S4 T STAR Biopharmaceutical production: Rapid nutrient and contaminant analysis of cell culture media by TXRF spectroscopy

Analysis of Trace Elements in Seawater Using the Thermo Scientific icap 7000 Series ICP-OES Duo

Determination of Elemental Bad Actors (As, Hg and Si) in Petrochemical Samples Using ICP-AES and ICP-MS

Agilent 6490 Triple Quadrupole LC/MS System REACH ULTIMATE SENSITIVITY WITH BREAKTHROUGH IFUNNEL TECHNOLOGY

XDS TM Multipurpose NIR-analyser for Laboratories

TurboMass GC/MS Software

Elemental Analysis. Choose the EAsy Way compeact

Agilent OpenLAB CDS. Manage your chromatography better than ever before

Featuring Analyst software under Windows NT for enhanced performance and ease of use. API 150EX. LC/MS System

MAKE NO MISTAKE, IT S UV THAT EVERYONE CAN USE. LAMBDA 265 / 365 / 465 UV/Vis Solutions

Wavelength-dispersive X-ray fluorescence spectrometer

// XPLORER-NS. Total Nitrogen and Sulfur Analyzer

Agilent solutions for contract research and manufacturing organizations

On site heavy metal testing and monitoring using monochromatic XRF methods

Spectroscopy Solutions for Pharmaceuticals:

MAX300-RTG PRODUCT NOTE. Real-Time Gas Analysis Process Automation and Control Product Quality Analysis. Industrial Process Mass Spectrometer

Analysis of elemental impurities in drug products using the Thermo Scientific icap 7400 ICP-OES Duo

The Agilent StreamSelect LC/MS Solution: Increasing the Throughput of a Triple Quadrupole Mass Spectrometer

INTRODUCTION. Journal of International Scientific Publications Ecology & Safety ISSN , Volume 9, 2015

Agilent 1220 Infinity II LC GET ON THE FAST TRACK TO HIGHEST EFFICIENCY AT A PRICE YOU CAN AFFORD

Faster, easier, flexible proteomics solutions

Agilent Resolve Raman. Handheld Through-Barrier Identification

ABSTRACT. This study investigates the use of inductively coupled plasma-optical emission spectrometry

NIRS DS2500 flour analyser

Don t Settle for just any Mercury Analyzer...Go with the Experts in Mercury Analysis...Go with Teledyne Leeman Labs

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

SCOPE OF ACCREDITATION TO ISO GUIDE 34:2009

GB Translated English of Chinese Standard: GB

Comprehensive Service Options for Your Lab

Ultima Expert Ultimate ICP-OES Spectrometer Best Performance & Ease-of-Use

Evaluation of Energy-Dispersive X-Ray Fluorescence for Mobile Analysis of Hazardous Metals in Transuranic Waste

ANALYTICAL GAS GENERATORS

Atomic Absorption Spectrometry. Quality is the Difference novaa

XRF DRIFT MONITORS DATA CALIBRATION MATERIAL

Transcription:

Agilent 4200 Microwave Plasma-Atomic Emission Spectrometer CHANGE IS IN THE AIR

RUNS ON AIR Analyze a broader range of samples while benefiting from the lowest cost of ownership. The safer, cost efficient Agilent 4200 MP-AES has higher sensitivity, detection limits down to sub ppb levels, speed that goes beyond flame Atomic Absorption (AA), and no combustible gases. Best of all, the next generation Agilent 4200 MP-AES runs on air. The Agilent 4200 MP-AES delivers: Lowest cost of ownership the Agilent 4200 MP-AES runs unattended without flammable or expensive gas supply, dramatically reducing your operating costs Improved laboratory safety in addition to eliminating flammable and oxidizing gases, the 4200 MP-AES eliminates the need to plumb multiple gases into the laboratory, or manually transport and handle gas cylinders High-performance magnetically excited microwave plasma source provides superior detection limits to flame AA Ease of use application-specific software applets plus plug-and-play hardware ensure any user can set up quickly without method development or alignment, and with minimal training Robustness and reliability ideal for industries such as mining, food and agriculture, chemicals, petrochemicals, manufacturing, and for remote locations Resource conservation protocols save time and gas and can even help save the environment. The Agilent 4200 MP-AES eliminates combustible gas usage, gas transportation, and standby power consumption. So you can use less gas and electricity, and help conserve our natural resources. www.agilent.com/chem/runsonair 2

PROVEN MP-AES TECHNOLOGY Our users talk about the benefits of MP-AES technology for their laboratory. With the MP-AES instrument Agilent seems to have hit a homerun for both gold analysis and base metal analysis. It provides superior detection limits and vastly expanded calibration range this enables quick easy analysis at trace levels as well as eliminates the need for time consuming dilutions of higher grade samples. All of this at an affordable price of well below that of ICP-OES and only slightly higher than top of the line AA units. BOBBY JOE REICHEL NEWMONT MINING CORPORATION, USA The results we have seen for our aqua regia soil extract samples are convincing, and those results are in very good agreement with the round robin, which was performed Europewide on those samples. FRANK SYMOSSEK SACHSENFORST, GERMANY Two important advantages of this instrument are its low running costs and laboratory safety, as no expensive or flammable gases are required. Considering cost, performance and multi-element capabilities, the Agilent MP-AES is a suitable and efficient alternative to flame AA for this application (determination of silicon in diesel and biodiesel) and presents better performance for critical elements such as the one investigated here. PROF. JOAQUIM A. NÓBREGA FEDERAL UNIVERSITY OF SÃO CARLOS, BRAZIL For your application Agilent is committed to providing solutions for your application. We have the technology, platforms, and expert guidance you need to be successful. FOOD & AGRICULTURE GEOCHEMICAL CHEMICAL & PETROCHEMICAL ENVIRONMENTAL Common applications for the Agilent 4200 MP-AES Major elements in foods, beverages and agricultural samples Cations in soils Nutrients in soils Metals in soil extracts Metals in agricultural soil samples Analysis of fertilizers Geochem samples in aqua regia digests Trace elements in geological samples Trace level gold in cyanide leach Analysis of high purity gold Platinum group elements in ore grade material Various elements in plating solutions Additives in lubricating oils Wear metal contaminants in used oils Analysis of coolant Analysis of petroleum, diesel and biodiesel fuel Major elements in polymers Analysis of raw chemicals for contaminant levels Hg, Pb, Cd and Cr in electronics and plastics (for WEEE/RoHs compliance) Heavy metals in soils As, Sb and Se in sediments and waste Analysis of waste waters, sediments and soils Analysis of plant waste products 3

MAKE THE CHANGE TO AIR The Agilent 4200 MP-AES is the next generation of proven MP-AES technology, offering significantly lower cost of ownership and safe, unattended analysis without the need for flammable or expensive gases. Lowest cost of ownership Gas supply is one of the highest costs associated with elemental analysis. Because the 4200 MP-AES runs on air, it vastly reduces the cost of ownership and eliminates the need for ongoing supply of flammable or expensive gases. Using the Agilent 4107 Nitrogen Generator, nitrogen is extracted from the air to provide a continuous nitrogen supply for plasma operation Increase sample throughput with safe, reliable, unattended multi-element analysis Eliminate hollow cathode lamps, deuterium lamps for background correction, and burner blockage Eliminate standby operating costs. When the Agilent 4200 MP-AES is off, no gas or power is used. Simply switch it on again when needed for analysis. Safety you can rely on No expensive acetylene and nitrous oxide gases, and no danger of flammable gas leaks No need to plumb multiple gases into the laboratory, making it ideal for remote locations such as mine sites or environmental monitoring stations No need to order, connect or replace cylinders, reducing your ongoing operating and servicing costs No transport or manual cylinder handling risks, and no risk of frozen regulators in cold climates No greenhouse gas emissions the Agilent 4200 MP-AES has zero fuel-based carbon emissions Cost saving US$ 200,000 US$ 150,000 US$ 100,000 US$ 50,000 US$ 0 MP-AES cost savings versus flame AA Saving you money For example, for the analysis of five elements in 100 samples measured three days per week, savings start within eight months. After 36 months, you ll save* over $80,000 in operating costs! * Savings may vary depending on factors including local gas costs, number and type of elements, etc. Visit the online MP-AES cost savings estimator to review your potential cost savings at www.agilent.com/chem/runsonair. US$ -50,000 0 20 40 60 80 Months www.agilent.com/chem/runsonair 4

REDEFINING ELEMENTAL ANALYSIS The Agilent 4200 MP-AES makes at-site analysis a reality. With rugged, reliable hardware, and intuitive software, any user can quickly become an expert. High performance for difficult samples Robust, magnetically excited microwave plasma source handles difficult matrices with ease, including fuels and organic solvents, geochemical samples, fertilizers and foods The Agilent 4200 MP-AES produces sensitivity, linear dynamic range, detection limits and analysis speed superior to flame AA Innovative torch design is vertically positioned for best performance with difficult samples, and features end-on axial viewing for excellent detection limits Fast and easy to use Easy-to-use, application-specific software applets automatically load a pre-set method so you can start analysis immediately without method development or alignment, and with minimal training Reliable torch loader automatically aligns the torch and connects gases for fast start up and reproducible performance Easy access to sample introduction components aid routine maintenance and troubleshooting, minimizing downtime The optional inert MP-AES torch enables direct measurement of HF digests, eliminating the need for a neutralization step, improving productivity and efficiency Lowest cost of ownership, improved laboratory safety, higher throughput, and easy to use it s time to switch to the Agilent 4200 MP-AES. Torch installation in three easy steps 1Open the torch loader 2Insert the torch 3Close the torch loader 5

INTUITIVE SOFTWARE THAT SAVES YOU TIME Application-specific software simplifies your workflow. With a familiar worksheet interface, automated method development, and software applets that include pre-set method templates, the Agilent MP Expert software saves you time. Wavelength and optimum parameters are preset and automatically recalled as you select the elements you need The comprehensive spectral library highlights potential interferences as you select each wavelength Spectral interferences are easily corrected for using the well characterized Inter Element Correction (IEC) technique established on ICP-OES, or the powerful Fast Linear Interference Correction (FLIC) technique Results are clearly displayed on screen, with large format number results for the current sample enabling easy tracking, even across a busy laboratory The instrument status display provides a comprehensive overview of current status and diagnostics for easy trouble shooting Recall and review previously stored data at any time, even while an analysis is in progress Quality control standards can be easily included to verify and confirm results during analysis Easily transfer results to a LIMS or other application using the flexible data exporting options MP Expert software is available in your choice of nine languages, so anybody can be confident running the system Three steps to analysis 1Click the icon. The applet automatically loads the pre-set method 2Enter sample labels, sample type, and weight/volume correction factors 3Load samples and run the analysis www.agilent.com/chem/runsonair 6

HOW IT WORKS The excitation source of the Agilent 4200 MP-AES is unique a magnetically excited microwave plasma. Robust and reliable At the heart of this plasma generation system is a robust and reliable industrial magnetron technology long proven in millions of microwave ovens around the world. By using the magnetic field rather than the electric field to couple the microwave energy into the plasma, the Agilent 4200 MP-AES produces a robust plasma expanding your application range. Light emission from the plasma is directed to a wide range, low noise charge coupled device (CCD) detector measuring spectra and background simultaneously while providing excellent detection limits and precision. Expanded Application Range The tuned waveguide and the mass flow control on the nebulizer gas enable a broader range of applications to be performed. Enhanced stability and precision Solid state CCD detector provides simultaneous background or interference correction. Lowest cost of ownership The nitrogen generator eliminates on-going gas requirements, dramatically reducing operating costs. Safe and efficient By running on air, the Agilent 4200 MP-AES eliminates flammable or oxidizing gases and the safety concerns of gas handling in your lab. Plug-and-play hardware Torch loader eliminates time consuming torch alignment and gas connections, getting you up and running fast. Rugged The standard sample introduction components can can handle almost all sample types from organics to acidic aqueous solutions. Organic capabilities Analyze organic samples quickly and efficiently using the external gas control module (EGCM), which injects air into the plasma, eliminating carbon buildup and reducing background. Reliable The optional optics purge and the innovative wavelength drive makes the 4200 MP-AES perfect for repeatable analysis in harsh on-site laboratory environments. 7

FOOD AND AGRICULTURE APPLICATIONS With high sample throughput and fast sequential measurement, the Agilent 4200 MP-AES is ideal for food screening laboratories. The Agilent 4200 MP-AES is ideal for contract laboratories where fast turn around is key, including small to mid-sized screening laboratories needing to determine essential nutrients and elements at major levels, and toxic elements at trace levels. With the lowest cost of ownership, the Agilent 4200 MP-AES will give you the edge over your competition by reducing your cost per analysis and improving performance Eliminate downtime waiting for gas refills, and achieve fast sample turn around with safe, reliable unattended analysis Reduce sample preparation. The axially viewed vertical plasma handles your toughest samples from food and soil digests to high salt soil extractions Achieve more than twice the sample throughput of conventional flame AA systems and never have to change burners/gases for different elements again Rapid method development and fast start-up means any user can achieve optimum performance Use the MultiCal feature in MP Expert software to analyze elements at high and low levels in the same analysis Complete wavelength coverage means you can avoid spectral interferences from majors by simply choosing another wavelength Include P and S in your elemental analysis suite with better detection limits using the MP-AES plasma emission technology Measured value and % recovery Certified Reference Material Ca % (% Recovery) Mg % (% Recovery) K % (% Recovery) Cu mg/kg (% Recovery) Fe mg/kg (% Recovery) Zn mg/kg (% Recovery) NIES No 7 Tea Leaves 0.314 (98) 0.15 (98) 1.86 (100) 7 (100) NIES No 10c Rice Flour 0.0095 (100) 0.127 (102) 0.279 (101) 4 (98) 10.6 (93) 21.8 (94) NIST 1577 Bovine Liver 0.0131 (106) 0.0625 (103) 1.000 (103) 185 (96) 266 (99) 125 (96) T0842QC Grapefruit Juice 0.0158 (109) 0.0091 (99) 0.1100 (100) Wide dynamic range for agriculture applications Results from analysis of acid extractable minor and major elements in agriculture and juice samples demonstrate the wide dynamic range and accuracy of the Agilent 4200 MP-AES. www.agilent.com/chem/runsonair 8

GEOCHEMICAL APPLICATIONS Revolutionize the way you do your business. With no ongoing-gas requirements, you can locate the Agilent 4200 MP-AES where your samples are. The Agilent 4200 MP-AES expands your application range. With no flammable gases and no cylinder handling hazards, the Agilent 4200 MP-AES is ideal for remote field placement. Slash your operating costs replacing your flame AA with the Agilent 4200 MP-AES can pay for itself in a matter of months, based on gas savings alone Improve your productivity with no need for ongoing gas supply, remote sites and mobile laboratories will never again have to deal with the issue of sourcing gas, or having gas delivered to a remote location Accuracy even with difficult samples vertical plasma torch provides excellent performance for tough samples with axial viewing for the best sensitivity The optional inert MP-AES torch enables direct measurement of metals in ore digests prepared using HF acid mixtures, eliminating the inefficient neutralization step Intensity 350,000 300,000 250,000 200,000 150,000 100,000 50,000 Au (267.595 nm) Calibration Correlation coefficient: 1.00000 0 0.00 5.00 10.00 15.00 20.00 25.00 30.00 35.00 40.00 45.00 50.00 Concentration (ppm) Accurate and precise gold analysis With better performance than flame AA, the 4200 MP-AES provides low ppb detection limits for gold. Shown is the excellent precision, extended range, and superb linearity, even in the most difficult geological matrices. 250,000 200,000 Blank Lu analyte Ni interferent 140 120 100 %TDS Ag 328.068 Pb 405.781 3.5 3 2.5 Intensity 150,000 100,000 % recovery 80 60 2 1.5 %TDS 50,000 40 20 1 0.5 0 0 0 547.470 547.524 547.600 FLIC spectral deconvolution Fast Linear Interference Correction (FLIC) enables automated interferent subtraction from the emission spectrum of the analyte of interest. Shown here is the FLIC model of a lutetium analyte peak, nickel interferent peak and blank emission. 547.655 Wavelength (nm) 547.709 547.763 Accurate recoveries in increasing matrix complexity Geochemical samples in complex matrices are easily handled using the robust 4200 MP-AES. Consistent recoveries for Ag and Pb with increasing %TDS from 0-3% are shown. 9

CHEMICAL AND PETROCHEMICAL APPLICATIONS Production demands and efficiency improvements impose increasingly tough demands on your business. Use the rugged and reliable Agilent 4200 MP-AES to provide fast, accurate results for difficult samples. With the lowest cost of ownership and improved ease of use, the reliable Agilent 4200 MP-AES is ideal for challenging samples from volatile organic solvents to used engine oils. Vertically oriented torch minimizes blockages, improving long term stability and reducing downtime Set up is easy just plug in the External Gas Control Module (EGCM). No special torch or plasma settings are required EGCM injects air into the plasma, preventing carbon build up and reducing background Air injection rate is software controlled, and can be changed as you switch between different elements in the sample Rapid method development auto-optimization enables you to select the optimum settings for each wavelength Perform sulfur determinations using a nitrogen purge of the optics Normalized Conc 1.5 1.4 1.3 1.2 1.1 1.0 0.9 0.8 0.7 0.6 0.5 0.4 0.3 0.2 0.1 0 00:00:00 01:00:00 02:00:00 03:00:00 04:00:00 05:00:00 06:00:00 07:00:00 08:00:00 09:00:00 10:00:00 11:00:00 12:00:00 Time (hh:mm:ss) Ag 328.068 Al 396.152 Ba 614.171 Ca 422.673 Cr 425.433 Cu 327.395 Fe 259.940 Mg 285.213 Mn 403.076 Ni 305.082 Pb 283.305 Si 251.611 Ti 334.941 V 309.311 Zn 213.857 Excellent long term stability Shown is an organics solution (ShellSol) achieving <2% RSD repeatability for all elements over 12 hours, using the Agilent 4200 MP-AES with the OneNeb nebulizer. Data was gathered under controlled laboratory environmental conditions within the instrument operating specification. www.agilent.com/chem/runsonair 10

ENVIRONMENTAL APPLICATIONS With simplicity and accuracy, the Agilent 4200 MP-AES is the right choice for the analysis of a broad range of environmental matrices. The 4200 MP-AES enables you to make the right decisions for your waste disposal ideal for QA/QC analysis of production streams and monitoring of metals content in solid and liquid waste. Simplify your analysis with auto optimization and auto background correction Measure your toughest samples accurately with a robust vertical plasma Reduce sample preparation of complex hydrofluoric (HF) acid digests using an inert sample introduction system that eliminates the need for a neutralization step, improving your productivity and efficiency % Recoveries of soil matrices Certified Reference Material (CRM) % Recoveries Cu Fe Mn P Pb Ti 2709a San Joaquin soil 101 98 104 92 106 98 2710a Montana I soil 100 98 105 97 98 95 2711a Montana II soil 105 102 106 96 101 94 Accurate recoveries for a variety of solid waste samples Shown are the recoveries of 3 soil CRMs after digestions with a complex acid mix, including HF acid. The digest was analyzed on the 4200 MP-AES using the inert sample introduction system. Excellent accuracy was achieved showing less than 10% deviation across 6 different elements. PERFORMANCE ENHANCING ACCESSORIES 4107 Nitrogen Generator for lowest cost of operation SPS 4 autosampler for unattended multi-element analysis Multi-mode Sample Introduction System (MSIS) for sub ppb detection of As, Hg and Se Switching Valve System (SVS 1+) for improved productivity External Gas Control Module (EGCM) for analysis of organic solvents and sulfur 11

For more information Learn more www.agilent.com/chem/runsonair U.S. and Canada 1-800-227-9770 agilent_inquiries@agilent.com Europe info_agilent@agilent.com Asia Pacific inquiry_lsca@agilent.com In other countries, please call your local Agilent Representative or Agilent Authorized Distributor visit www.agilent.com/chem/contactus This information is subject to change without notice. Agilent Technologies, Inc. 2015 Printed in the USA July 1, 2015 5991-3696EN Maximize your productivity and data quality with genuine Agilent parts and supplies For more information see: www.agilent.com/chem/specsuppliesinfo Services let you focus on what you do best Whether you need support for a single instrument or multiple labs, Agilent can help you solve problems quickly, increase uptime, and maximize the productivity of your team with: On-site maintenance, repair and compliance. Service agreements for all your systems and peripherals. Application training and consulting from our dedicated, worldwide network of specialists. Agilent Service Guarantee If your Agilent instrument requires service while covered by an Agilent service agreement, we guarantee repair or we will replace your instrument for free. No other manufacturer or service provider offers this level of commitment to keeping your lab running at maximum productivity. Leading the way in atomic spectroscopy innovation www.agilent.com/chem/atomic Agilent AA Agilent MP-AES Agilent ICP-OES Agilent ICP-MS Agilent ICP-QQQ