Real Property Acquisition Loss Control Checklist

Similar documents
PRESCRIPTIVE COMPLIANCE METHOD

Commercial Remodel Permit

FEMA P-593 STEP-BY STEP PRESCRIPTIVE RETROFIT FOR CRIPPLE WALL BRACING & ANCHORAGE TO FOUNDATION

HERMIT S REST GRAND CANYON NATIONAL PARK BUILDING CODE REVIEW

PRESCRIPTIVE COMPLIANCE METHOD

STATE UNIVERSITY CONSTRUCTION FUND

City of Walnut Creek Development Review Services 1666 N. Main Street, Walnut Creek, CA (925) phone (925) fax

TO MEMBERS TO THE COMMITTEE ON GROUNDS AND BUILDINGS: DISCUSSION ITEM UNIVERSITY SEISMIC SAFETY POLICY AND UPDATE ON PROGRAM FOR SEISMIC IMPROVEMENTS

REQUIREMENTS FOR SUBSTANTIALLY DAMAGED AND SUBSTANTIALLY IMPROVED STRUCTURES

Elko County Building & Safety Division

BROCHURE # 108 CONSTRUCTION PLAN COMPONENTS

BUILDING CODES & DESIGN CRITERIA

Ordinance No July 1, 2016

Inspection of New One- and Two- Family Dwellings

RESIDENTIAL CONSTRUCTION New Dwellings and Additions

Residential Inspector s Guide: Building and Energy based on the 2009 International Residential Code Chapters 1-11

Residential Inspector s Guide: Building and Energy based on the 2009 International Residential Code Chapters 1-11

CALIFORNIA COMMERCIAL BUILDING INSPECTOR CONTENT OUTLINE 01. GENERAL ADMINISTRATION 6% Project Administration 1%

City of Tacoma Planning and Development Services

Code Requirements for Existing Buildings. R. W. Sullivan, Inc. 529 Main St., Suite 203 Charlestown, MA (617)

SEISMIC RESPONSE, EVALUATION, AND RECONSTRUCTION OF THE DVA SEPULVEDA CAMPUS FOLLOWING THE 1994 NORTHRIDGE, CALIFORNIA, EARTHQUAKE

Rebuilding your Home after the storm? Adding on, renovating, or remodeling your home? Here's information YOU need to know about the 50% Rule.

APPLICATION AND CERTIFICATE FOR PAYMENT

CITY OF CAMDENTON OFFICE OF THE BUILDING OFFICIAL Commercial Building & Architectural Review Permit Application

CITY OF HAGERSTOWN PLANNING & CODE ADMINISTRATION DEPARTMENT. Submittal Requirements

Demolition Safety!!!!

Structural Assessment Report 2118 Milvia Street Berkeley, California

Structural Tests and Special Inspections Form. Inspection of Fabricators (1704.2)

TOWN OF ROTTERDAM RESIDENTIAL BUILDING PERMIT APPLICATION Ext. 395 Needed to Obtain Permit:

Supplemental Plan Check List for Unreinforced Masonry (URM) Retrofit

BELLA PALERMO HOMEOWNERS ASSOCIATION MAINTENANCE MATRIX DIVISION OF MAINTENANCE AND REPAIR RESPONSIBILITY

Project Address Applicant: (Please Print) Plan review Engineer: Phone: Date

RESIDENTIAL BUILDING PLAN REQUIREMENTS

The Building Codes A.R.E. Building Design and Construction Exam Prep

The California State University Office of the Chancellor CSU SEISMIC REQUIREMENTS

Structural Engineering

The Homeowner s Building Application Checklist for Constructing a Residential Addition

HOUSE REPAIRS & RENOVATIONS BUILDING PERMIT REQUIREMENTS

PLAN REVIEW REQUIREMENTS FOR RESIDENTIAL CONSTRUCTION

Application for Commercial Plan Review and Building Permit. Address:

5.0 Elevating Your Home

SUBSTANTIAL IMPROVEMENT

LATERAL DRIFT DESIGN IN COLD FORMED STEEL WALL SYSTEMS

PERMIT APPLICATION CHECKLIST Municipal Address, Phone & Fax NONRESIDENTIAL

SUBMISSION GUIDE FOR ARCHITECTS

STRUCTURAL CONDITION ASSESSMENT

FEMA 356 Life Safety Building Performance Evaluation & PML Analysis

Property Condition Assessment

Part III Building Planning and Construction BUILDING PLANNING CHAPTER 3

CITY OF CEDAR FALLS DEPARTMENT OF DEVELOPMENTAL SERVICES INSPECTION SERVICES DIVISION PHONE Residential Accessory Structures

Building Inspection Report

Mitigation Measures for Natural Hazards

EMERGENCY MANAGEMENT PREPAREDNESS AND ASSISTANCE TRUST FUND ARC 4496 Evaluation Questionnaire

Specific Plan Check Requirements for Residential Construction

Residential Building Permit Application

Plan Check No. Checked by: An Appointment Is Required for Verification

The Inspection Process. Waxhaw N.C.

COLUMN SPACING TRUCK ACCESS/DOORS EAVE HEIGHT UTILITIES PARKING & DRIVES

Fire Inspection and Code Enforcement, 7 th Edition. Chapter 6 Building Construction: Components Inspector II

SECTION SEISMIC RESTRAINT REQUIREMENTS FOR NON-STRUCTURAL COMPONENTS REVISED PART 1 GENERAL 1.1 DESCRIPTION:

Administrative Changes

BUILDING INTEGRITY SUMMARY REPORT

4. Number of drawings required: ( ) Locations of nearest streets

Chapter 1: Application and Administration

#402 New Residential Submittal Checklist

Minimum Requirements For One & Two Family Structures FBC 6 th Edition (2017)

Seismic Design Requirements

AMERICAN RED CROSS EMERGENCY PREPAREDNESS ACADEMY Presented by Michael J. Griffin, P.E. Principal CCS Group, Inc.

RESIDENTIAL BUILDING REQUIREMENTS

Applying the Building Code During Design

R CODE CHANGE PROPOSAL FORM (See instructions on page 2)

PLASTIC CHAPTER 26. SECTION 2602 DEFINITIONS Definitions. The following terms are defined in Chapter

RESIDENTIAL BUILDING PERMIT CHECKLIST FOR THE CITY OF SANTA ROSA

PRELIMINARY STRUCTURAL INVESTIGATION REPORT

1.0 Total Points % 2.1 Building Exterior Elements % 2.2 Accessibility % 2.3 Structural %

Available at: Last Modified: December 2012

ACCESSORY STRUCTURE Building permit information For 1 & 2-family dwellings

RESIDENTIAL NEW CONSTRUCTION PLAN REVIEW CHECKLIST

Chapter 2 EARTHQUAKE-RESISTANCE REQUIREMENTS

Estimating & Scope. Additional Lessons Tools / Measuring / Masonry / Framing/

City of Richmond Zoning Ordinance Page 12-1

BUILDING PERMIT INFORMATION GUIDE FOR THE HOMEOWNER

CITY OF GLASGOW BUILDING PERMIT APPLICATION 126 E. Public Square Glasgow, KY Phone: (270) Fax: (270)

Natrona County Development Department 200 North Center Street, Room 205 Casper, WY Phone: Fax:

BOWIE LEARNING CENTER

Brent Ellmann Structural Option 200 Minuteman Park, Andover, MA Structural Consultant: Dr. Hanagan

CHAPTER 26 PLASTIC SECTION BC 2601 SECTION BC 2603 GENERAL FOAM PLASTIC INSULATION

Minnesota Healthcare Engineers Association, Fall Conference. Bob Dehler, P.E. Engineering Program Manager September 14, 2017

ARCHITECTURAL EXPANSION JOINT PRE-INSTALLATION INSPECTION

CODE COMPLIANCE PLAN REVIEW PROCEDURES

Importance Category and Seismic Restraint

Structural Requirements

COOLIDGE SENIOR HIGH SCHOOL

BUILDING CODES Presented by CORUM ENGINEERING

ORDINANCE. APPROVED EMERGENCY: (Yes) (No) VETOED: Date

2016 Port of San Francisco Building Code

Building Permits A Guide for Homeowners

2015 IBC Exit Systems

The designer shall also submit additional information required by the University as described and underlined below.

Transcription:

The following checklist will help identify items that have an important bearing on the safety of the building and to protect contents from damage. It is not intended as an all inclusive list of protection against earthquakes, severe storms, flooding, or wildfires, but contains basic elements for loss resistance. Disclaimer This form is designed to be a guide to loss control and safety issues when acquiring real property. Not all elements of loss are included in this form. The information provided is not intended to include all potential risk or controls. Use of this form does not warrant that all loss and/or claims will be avoided if the program information is followed. By using information in this form, the authors, in no way intends to relieve the Client of its own duties and obligations, nor is Alliant Risk Control Services undertaking, on behalf of or for the benefit of Client or others, that the Client s property or operations are safe, healthful, or in compliance with any law, rule or regulation. Client s remain responsible for its own efforts to reduce risks and should consult their own legal counsel for appropriate guidance.

General Property Information Date: Property Name: Property Address: Building Occupancies: Year Built Sq.Ft. Number of Stories Building Construction Type Physical Condition Please read the following questions and record answers using a Y for Yes, N for No or U for Unknown or Comment in the section. Property Characteristics Yes No Unknown/Comment Automatic Fire Sprinkler System Fire or Smoke Detection Burglary Protection Electrical Updates within last 15 years Roof replaced within 10 years Areas of Occupancy Architectural as built plans available Neighboring exposure within 50 feet Hazardous operations within 200 feet of property Subterranean Floor (including parking) Elevator Historic Issues Asbestos Lead (paint, pipes) Phase I assessment and other environmental reports available Neighboring buildings in good condition, well maintained

Property Characteristics Yes No Unknown/Comment Evidence of vandalism, tagging, break in, etc. Any history of loss, (fire, water damage) Exterior lighting adequate, (parking, sidewalk, building access) Existing warranties, (roof, mechanical, elevator, etc.) Flood Zone verified History of nearby wildfire Wildland within 100 feet of building Is the nearest fire hydrant more than 500 feet away Fire truck access to the property and all sides of the building Is the building subject freezing weather HVAC and mechanical system reports available Piping replacement or updates within 15 years Copies of building service, maintenance and other contracts

ADA Characteristics This portion of the assessment is designed to help evaluate if existing conditions of the building meet basic ADA guidelines. Ideally, the layout of the building should allow people with disabilities to obtain access, materials or services without assistance. ADA Characteristics Yes No NA/Unk/Comment Reports showing compliance with ADA? Does the building have an accessible entrance? Is there an accessible entrance that provides direct access to the main floor, lobby and elevator? Slopes of accessible ramps not greater than 1:12 Do public spaces have at least one accessible route? Are there ramps, lifts, or elevators to all public levels? Are accessible routes at least 36 inches wide? Accessible parking spaces available closest to accessible entrance? Do doors into public spaces have at least a 32 inch clear opening? If emergency systems are provided, do they have both flashing lights and audible signals? If rest rooms are available to the public, is at least one rest room (either one for each sex, or unisex) fully accessible? Handrails as appropriate

Earthquake Risk Assessment It is recommended that all acquisitions follow the CSU Seismic Policy Manual. Newly leased or licensed space may be occupied only if it satisfies the seismic safety requirements of this Standard at the time the lease or license is executed, which can be established by one of the following: 1. A determination that a Waiver Letter can be issued, see Section 8.2.A, or 2. A FEMA 154 Evaluation Report that indicates the building is not expected to pose a seismic safety risk, see Section 8.2.B, or 3. A Certificate of Applicable Code indicates the building was designed to modern Code requirements and does not have characteristics known to be hazardous, see Section 8.2.C, or 4. An Independent Review Report that states that the building has an earthquake damageability Level of IV or better, as defined in the table Earthquake Performance Levels for Existing Buildings, see Attachment D of the CSU Seismic Policy Manual. Acquire by Purchase or Title Transfer Whenever a building is acquired by purchase or other title transfer (e.g. exchange, gift), the due diligence examination of the property shall include a signed and stamped independent review report from a structural engineer licensed in the State of California or the state in which the property is located that meets the requirements of Section 8.2.C, Independent Review Report, below. See also Earthquake Performance Levels for Existing Buildings in Attachment D. Prior to acquisition of a building(s), CSU shall evaluate the building(s) and report on its seismic damageability. By Standard, a newly acquired building that has an evaluation of Level IV or better seismic performance may be occupied or continue to be occupied. A building with a Level V rating may be occupied or continue to be occupied only if the comprehensive and feasible budget and retrofit plan is in place at acquisition to retrofit it to achieve a Level IV within five years. A building with Level VI or poorer ratings must be seismically retrofitted to achieve a Level IV or better rating before it may be occupied. If the hazard classification depends on the seismic performance of adjacent structures, then mitigation can be achieved either by modification of the adjacent building hazard, or by protecting the subject building from the consequences of the adjacent building s seismic performance. Any retrofit work undertaken as part of a purchase to meet an assigned Level must be independently peer reviewed by CSU s structural engineer. The peer review shall be of the retrofit or modification design prior to construction and continue through completion of construction for conformance with the asserted Level. See also Earthquake Performance Levels for Existing Buildings given in Attachment D. The requirements of this section may be waived if the building is unoccupied, will remain unoccupied after purchase, is to be demolished, will be sold without occupancy, or is a one or two story, woodframed single family residence on a level site.

The following building characteristics describe the types of building configuration or feature that can make a building less vulnerable to earthquake damage. This does not mean, however, that there is a low risk of earthquake damage. Additional risk may be imposed on a building due to its irregular features, presence of brick veneer, and vulnerable foundation types. Characteristics that could make your building more vulnerable to earthquake damage may not be as important if your building was professionally designed. In that case, the building should have been designed in a way that accounts for the features listed below. Building EQ Characteristics Yes No Unknown/Comment Seismic risk assessment (PML) reports and geotechnical soil reports Seismic Updates? If yes, list dates and type of updates. Does the building have a box like shape? Is the roof free of openings, such as for access doors or skylights, or are the openings minimized to dimensions of less than 12 feet or less than 50 percent of the smallest roof dimension? Have light roofing materials been used, such as asphalt shingles and metal panels or tiles? Is the building free of large garage doors, first story parking lots or other large ground floor openings in multiple story buildings? Does the building s exterior limit or exclude the use of brick or stone veneer? The foundation of a structure plays a crucial role in the structure's performance during an earthquake. There are several types of foundation systems. A slab on grade is a foundation system built directly on the ground, compared to crawlspace or pier foundations where the floor is elevated above the grade. The slab on grade system and a crawlspace that uses a continuous masonry or concrete wall are the most resistant to earthquake damage. Which system best describes the building foundation system: Yes No Unknown/Comment Slab on grade with integral footing (the footing and slab are a single unit) Crawlspace or basement foundation wall system consisting of a continuous concrete or masonry wall system Crawlspace or basement foundation wall systems consisting of a wood stud cripple wall or an un reinforced masonry wall. Pier or pile foundation system consisting of wood, concrete, or steel

Note: A professional civil engineer should always be consulted when any structural improvements are being considered.

Fire and Life Safety Refer to the following checklist for additional actions that should be taken to protect employees, customers and visitors, as well as building, contents and inventory regardless of the building s configuration. Fire and Life Safety Earthquake Considerations Yes No Unknown/Comment Do the windows, skylights and doors have either tempered glass or safety film applied on the interior side of the glass, to reduce the chances of the glass shattering? Are natural gas lines outfitted with flexible connections and an automatic shut off valve? Have flexible stainless steel supply lines been installed leading to toilet(s)? Were flexible couplings used on the sprinkler systems? Are sprinkler systems earthquake braced? Are major appliances, such as boilers, furnaces, and water heaters, braced to the wall and/or floor so the appliances will not overturn or shift in the event of an earthquake? Are the hangers (usually strips of sheet metal or stiff steel rods) used to support your mechanical and plumbing systems 12 inches or less in length? Are suspended ceilings braced to the structure to limit the amount of displacement during an earthquake?

Notes: 1. Earthquake damageability levels are indicated by Roman numerals I through VII. Assignments are to be made following a professional assessment of the building s expected seismic performance as measured by the referenced technical standard and earthquake ground motions. Equivalent Arabic numerals, fractional values, or plus or minus values are not to be used. These assignments were prepared by a task force of state agency technical personnel, including California State University, University of California, Department of General Services, Division of the State Architect, and Administrative Office of the Courts. The ratings apply to structural and non-structural elements of the building as contained in Chapter 34, CBC requirements. These definitions replace those previously used by these agencies. 2. Chapter 34 of the California Building Code, current edition, regulates existing buildings. It uses and references the American Society of Civil Engineers Standard Seismic Rehabilitation of Existing Buildings, ASCE-41. All earthquake ground motion criteria are specific to the site of the evaluated building. The CBC definitions for earthquake ground motions to be assessed are paraphrased below for convenience: BSE-2, the 2,475-year return period earthquake ground motion, or the 84th percentile of the Maximum Considered Earthquake ground motion for the site. BSE-C the 975-year return period earthquake ground motion. BSE-1, two-thirds of the BSE-2, nominally, the 475-year return period earthquake ground motion. BSE-R the 225-year return period earthquake ground motion. Risk Category is defined in the CBC Table 1604.5. The Risk Category sets the level of required seismic building performance under the CBC. Risk Category IV includes acute care hospitals, fire, rescue and police stations and emergency vehicle garages, designated emergency shelters, emergency operations centers, structures containing highly toxic materials where the quantities exceed the maximum allowed quantities, among others. Occupancy categories I-III include all other building uses that include most state owned buildings. 3. Implied Risk To Life is a subjective measure of the threat of a life threatening injury or death that is expected to occur in an average building in each rank following the indicated technical requirements. The terms negligible through dangerous are not specifically defined, but are linguistic indications of the relative degree of hazard posed to an individual occupant. 4. Implied Damageability is the level of damage expected to the average building in each rank following the indicated technical requirements when a BSE-1 level earthquake occurs. Damage is measured as the ratio of the cost to repair the structure divided by the current cost to reconstruct the structure from scratch. Such assessments are to be completed to the requirements of ASTM E- 2026, where the damage ratio is the Scenario Expected Loss (SEL) in the BSE-1 earthquake ground motion evaluated at Level 1 or higher in order to be considered appropriate. 5. The engineer assessing the Earthquake Performance Level using the noted requirements may conclude that the expected seismic performance is consistent with a rating one-level higher or lower than the one assigned by the Table. An alternative rating may only be assigned if an independent technical peer reviewer concurs in the evaluation. The peer review must be completed consistent with the requirements of CBC Chapter 34. The ratings levels shown in the second column under Peer Review may be assigned when so documented. Note that peer review is unlikely to improve buildings rated as VI or VII because they have fundamental seismic system flaws. The ratings for I and II are unchanged because the performance increment between levels is so large and it is highly unlikely that a revision could be justified 6. Historically the University of California has used the terms good, fair, poor and very poor to distinguish the relative seismic performance of buildings. The concordance of values is approximate; the former rating procedures did not specify specific performance levels as is done herein, but were sentence fragments for qualitative performance. For reference the historically used Division of the State Architect and Seismic Safety Commission levels correspond approximately to the new numerical values.