Table Air Barrier and Insulation Inspection Component Criteria

Similar documents
Appendix RA Air Sealing and Insulation Key Points COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA

Feature Zone IECC 2009 IECC

Hardin County Planning and Development Commission

A Closer Look Inspection Service 2015 IECC Residential DFW area handout

Boulder City NV Prepared by (Print Name) Signature Date

Michigan Energy Code Training and Implementation Program

Prescriptive Checklist for the 2015 Washington State Energy Code

2015 Michigan Residential Code Energy Worksheet for New Single-family Residential Building

A.ENVELOPE AIR SEALING

2012 IECC Residential with State Adopted Changes

Fenestration Components: Mechanical Summary. Water heater energy factor: Ef Fuel type: Gas Electric Other

IRC 2012 Key Changes

Insulation, Fireblocking, Draftstopping and Crawl Space Requirements REVISION DATE: JANUARY 2017

Date Rater Verified. Rater Verified. Slab / Pre-Drywall / Thermal Inspection

Presentation Overview: NC Energy Code RESNET Standards HERS Index HERS Verification Process

Quick Reference Guide for 2009 IECC Residential Energy Efficiency Climate Zone 5 and Marine 4

PREP + INSULATION. DISCLAIMER: These tools are for illustrative purposes only and

Quick Reference Guide for 2009 IECC Residential Energy Efficiency Climate Zone 6

REScheck Software Version Compliance Certificate

2018 WEATHERIZATION SPECIFICATIONS MANUAL

Montana Homebuilder Brief: Residential Energy Code 1

RESIDENTIAL ENERGY EFFICIENCY

Instructions for the Residential Building Data Collection Checklist 2009 International Energy Conservation Code with 2011 Georgia Amendments

Subject: Energy Subcode Compliance. Reference: N.J.A.C. 5: (f)1.vi, 2.18(b) and 3.18

Energy Code Basics for Residential Buildings. Presented by Newport Ventures NEWPORT VENTURES

10 Steps to Save Energy in Your House

INSTALLING WATER-RESISTIVE BARRIERS & FLASHING

City Building Code Supplement

The Inspection Process. Waxhaw N.C.

Plan Check & Field Inspection Guide

Inspection of New One- and Two- Family Dwellings

SAN MIGUEL COUNTY & TOWN OF MOUNTAIN VILLAGE BUILDING DEPARTMENTS PRESCRIPTIVE ENERGY CODE & GREEN BUILDING STANDARD

BUILDING ENERGY CODES UNIVERSITY

Insulation Technologies and Installation Specifications for Better Energy Performance of Commercial Buildings

Chapter 19 - Interior Insulation

Part IV Energy Conservation

Vermont Residential Building Energy Code. Handbook. A Guide to Complying with Vermont s Residential Building Energy Standards (30 V.S.A.

Home Energy Savings Program. Utah Participating Weatherization Trade Ally Program Manual

TOWN OF SOUTH KINGSTOWN REQUIREMENTS FOR BUILDING PERMITS RESIDENTIAL SINGLE FAMILY ADDITIONS

Town of Derry New Residential Building Permit

Residential Building Inspections

Quality Inspection 8618 London Heights San Antonio, TX Phone: (210)

Article 14 - Indiana Residential Code, Chapter 11: Energy Efficiency

2006 INTERNATIONAL ENERGY CONSERVATION CODE

FIBERGLASS BATTS ACHIEVING GRADE I INSULATION WITH. Prepared by

2010 National Building Code Adoption and Associated Process Changes

HOUSING ENERGY- EFFICIENCY INSPECTION FIELD MANUAL

BASEMENT FINISH PERMIT AND BUILDING CODE REQUIREMENTS (REVISED 3/6/2018)

Radon Vent Pipe System. Labeling Performance Indicators

Energy Efficiency: Designing Wood-Frame Buildings for Occupant Comfort

Typical Finished Basement Details

RESIDENTIAL NEW CONSTRUCTION PLAN REVIEW CHECKLIST

HPW Protocol Reference Manual

Retrofit Installer / Shell

Compliance Certificate

Low-cost Construction for High-energy Savings. Brian J. Wimmer Construction Manager Rochester Area Habitat for Humanity

The New 8 th Edition of the Massachusetts State Building Code. presented by: Larry Abatiell, PE Architectural Service Director

2017 SPECIFICATIONS MANUAL ENERGY TRUST OF OREGON EXISTING HOMES

Administrative Changes

New Hampshire Residential Energy Code

Wisconsin Focus on Energy Attic Air Sealing and Insulation Material and Installation Guidelines Version 1.1 January 23, 2013

Michigan Energy Code Training and Implementation Program

Condi1oned A3cs and Crawlspaces. Making the Decision. Find This Presenta1on. Helpful Informa1on. page/

City of High Point Airport Overlay District Noise Level Reduction Design Standards

A LOOK INTO THE 2015 IECC RESIDENTIAL PROVISIONS. Presented by: Shaunna Mozingo, Colorado Code Consulting

Knauf Makes It Easy to Insulate

HCM UNIVERSITY OF ALASKA FAIRBANKS Building Challenges in Alaska UNIVERSITY OF ALASKA FAIRBANKS

2015 IECC Residential Basic Principles Updates with State Amendments

Work Write Up / Specification of Repairs HUD DIVISION 1. MASONRY HUD DIVISION 2. SIDING. Toll Free

1998 and 2000 International Energy Conservation Code Version 3.0 April 2000

Crawl Space Moisture Control

Single Family Residence Building Permits

CHAPTER 1: OVERVIEW OF ENERGY EFFICIENT CONSTRUCTION

Structural. Orientation of the Home. Northeast Oklahoma REC s Energy Efficient Tips for Home Builders

Fairfax County, Virginia

Applying for Permits to build a new house in Linn County

THE GEORGIA ENERGY CODE: 2009 IECC + AMENDMENTS

CERTIFICATE OF FIELD VERIFICATION & DIAGNOSTIC TESTING (Page 1 of 8)

Compliance Certificate

One and Two Family Additions

Truss Heel Heights and Energy Code Requirements. Overview Revised 2/17/2017

EcoTouch Insulation with PureFiber Technology

APPROVED. Acceptable to the code official for compliance with the provisions of the applicable Code or referenced Standard.

General Residential Code Requirements

REScheck Software Version Compliance Certificate

Recommended Amendments to the 2012 International Residential Code (IRC)

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION SECTION: AIR BARRIERS REPORT HOLDER:

Quality Insulation Installation (QII) Handbook

e n H i Brought to you by

CLEAResult CONTRACTOR OPERATIONS GUIDE

DOE Zero Energy Ready Home Technical Training

RESIDENTIAL ENERGY EFFICIENCY

Trusted DIVISION: 07 SYSTEM. Conformity! ICC-ES Evaluation. not specifically. Copyright 2014

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: THE DOW CHEMICAL COMPANY

Chapter 1: Compliance

How Does Insulation Work for You? 2. Insulating a New Home 10. Make Your Selection 14. Check the Label Before You Buy 14. Can You Do It Yourself?

Is Yours? Homes Across Missouri are Being Built to the Latest National Energy Efficiency Standards

California Building Envelope Solutions

High Performance, Energy Efficient Design for Wood Frame Buildings

1 Exam Prep Prov Module: Thermal and Moisture Protection Questions and Answers

Transcription:

Table 40.4. Air Barrier and Insulation Inspection Component Criteria NUMBER COMPONENT CRITERIA Air barrier and thermal barrier Exterior thermal envelope insulation for framed walls is installed in substantial contact and continuous alignment with building envelope air barrier. Breaks or joints in the air barrier are filled or repaired. Air-permeable insulation is not used as a sealing material. Air-permeable insulation is inside of an air barrier. Ceiling/attic Air barrier in any dropped ceiling/soffit is substantially aligned with insulation and any gaps are sealed. Attic access (except unvented attic), knee wall door, or drop down stair is sealed. Walls Corners and headers are insulated. Junction of foundation and sill plate is sealed. 4 Windows and doors Space between window/door jambs and framing is sealed. 5 Rim joists Rim joists are insulated and include an air barrier. 6 Floors (including above-garage and cantilevered floors) Insulation is installed to maintain permanent contact with underside of subfloor decking. Air barrier is installed at any exposed edge of insulation. 7 Crawl space walls Insulation is permanently attached to walls. Exposed earth in unvented crawl spaces is covered with Class I vapor retarder with overlapping joints taped. Shafts, Duct shafts, utility, knee walls and flue shafts opening to exterior or unconditioned space are sealed. 9 Narrow cavities Batts in narrow cavities are cut to fit, or narrow cavities are filled by sprayed/blown insulation. 0 Garage separation Air sealing is provided between the garage and conditioned spaces. Recessed lighting Recessed light fixtures are air tight, IC rated, and sealed to drywall. Exception fixtures in conditioned space. Plumbing and wiring Insulation is placed between outside and pipes. Batt insulation is cut to fit around wiring and plumbing, or sprayed/blown insulation extends behind piping and wiring. Shower/tub on exterior wall Showers and tubs on exterior walls have insulation and an air barrier separating them from the exterior wall. 4 Electrical/phone box on exterior walls Air barrier extends behind boxes or air sealed-type boxes are installed. 5 Common wall Air barrier is installed in common wall between dwelling units. 6 HVAC register boots HVAC register boots that penetrate building envelope are sealed to subfloor or drywall. 7 Fireplace Fireplace walls include an air barrier. leakage provisions of section 40.4 of the. It does not cover all airsealing locations or techniques. Other code provisions may be

Air sealing key points lights and bath vent fans to ceiling drywall Fan vented through exterior wall sealed at penetration airtight IC-rated recessed light fixtures to drywall plumbing (if ceiling is insulated) Insulate and install sheet material behind bathtub Insulate headers Insulated exterior wall Insulate corners 4 Window sealed into rough opening using backer rod FACED BATTS UNFACED BATTS Ladder T-wall SUBFLOOR 9 gap between electrical box and drywall FLOOR JOIST Caulk Narrow stud cavity batts are cut to fit Caulk 4 wiring and plumbing Electrical panel box, recommend install on interior (non-insulated) wall. If installed on exterior wall, air barrier shall extend behind box or air-sealed box shall be installed. the. It does not cover all

Chases and common by-passes Cap top of chase with solid air barrier and insulate above dropped soffit chases top plate MULTIFAMILY COMMON WALL Caulk electrical boxes and fixtures to drywall INTERIOR WALL 6 HVAC electrical Install air barrier on interior of all insulated walls bottom plate 5 in common wall plumbing bottom plate 6 HVAC boot Shower/tub drain rough opening Install and seal air barrier behind tub (required) bathtub drain penetration the. It does not cover all

Window rough opening Wall cross-section Attic ventilation 4-inches Wind wash baffle and dam for air-permeable insulation Soffit vent Glue drywall to top and bottom plates Caulk bottom plate to subfloor 4 Caulk band joist to subfloor and plates 5 Use backer rod or spray foam (appropriate for windows) to fill gaps between window/door and rough opening Glue drywall to top plate Tape or caulk exterior sheathing seams Glue drywall to bottom plate. Caulk bottom plate to subfloor, foundation, or slab Sill gasket or double-bead of caulk under bottom plate Install exterior water resistive barrier as per IRC 70. -inch inspection gap Insulation is permanently attached to walls 7 ed CLASS I vapor retarder required in crawlspace 6 Underfloor insulation must be installed in permanent contact with subfloor (air barrier required at any exposed edge of insulation) 4 the. It does not cover all

Combustion chase 7 around chimney flues with sheet metal cap Combustion closet Combustion air inlets as per mechanical and/or fuel gas code Flue stack Rigid foam option (recommend covering with ignition barrier for fire protection) Internal air barrier gas and plumbing through walls Blocking above suporting wall for cantilevered floor (required) Insulated walls (not required unless walls are part of building thermal envelope) Insulation above top plate of supporting wall 6 Underfloor insulation must be installed in permanent contact with subfloor (air barrier required at any exposed edge of insulation) Insulated water heater (not required) 4 Door closes against solid threshold Bottom plate sealed Exterior Caulk exterior wall for refrigeration lines, condensate line, etc. Solid (non-louvered) door with weatherstripping 5 the. It does not cover all

Install blocking and rafter baffle to prevent wind-washing if vented, insulated roofline (required) R- insulation R- + R-5, R-5 + R-, or R-9 in x6 ed attic-side air barrier (required) OSB, insulated sheathing, etc. Blocking - fit in joist cavity, caulked or foamed Attic knee-walls Two-level attic Unconditioned Space Caulk and seal rough opening Air barrier required, (rigid board recommended) Caulk Caulk Attic kneewall requires R- insulation Glue Blocking 6 Rigid insulation Minimum R-5 Weather-strip door opening and threshold Conditioned space Conditioned space the. It does not cover all

Attic scuttle Insulation dams prevent loose-fill insulation from falling through access Hatch lid pushes up and out of the way for access Rigid insulation plus batt, minimum R-9 Trim Air seal gasket Attic pull-down stairs Rigid insulation box forms lid for pull-down attic staircase Insulation dams prevent loose-fill insulation from falling through access Cover box pushes up and out of the way for access Minimum R-5 Boxed enclosure for staircase has rigid hinged lid with insulation on top Insulation batt minimum R-5 Weatherstripping Weatherstripping Attic access Weatherstripping Panel gap between frame and rough opening with caulk, backer rod, or foam Attic pull-down stairs Insulation dams prevent loose-fill insulation from falling through access gap between frame and rough opening with caulk, backer rod, or foam Weatherstripping 7 Insulation board minimum R-5 Panel the. It does not cover all

Air barrier behind steps 0 Garage to house door Garage (unconditioned) Web trusses Basement (conditioned) Rigid foam (recommend covering with ignition barrier, if required) Inset garage to house door Garage (unconditioned) Web truss Air seal 0 Sheath and insulate Basement (conditioned) Rigid foam (recommend covering with ignition barrier, if required) the. It does not cover all

Roofline Installed Insulation Options Reference Table 40.6 in Georgia amendments to the and section 06.4 in the Georgia amendments to the 006 IECC Air impermeable installed insulation (e.g., spray foam insulation) Shingles Roofing felt Decking (e.g., open- or closedcell spray foam) R-9 minimum if trade-offs are used (Georgia requirements) Air-permeable installed insulation (e.g. fiberglass, cellulose) Shingles (e.g. rigid foam board) R-5 minimum in climate zones & R-5 minimum in climate zone 4 Option Roofing felt (e.g. rigid foam board) Decking Air-permeable insulation Air-permeable insulation R-9 minimum if trade-offs are used (Georgia requirements) Shingles Option Roofing felt 9 (e.g. rigid foam board) Air-permeable insulation Decking (e.g. rigid foam board) R-5 minimum in climate zones & R-5 minimum in climate zone 4 Air-permeable insulation R-9 minimum if trade-offs are used (Georgia requirements) the. It does not cover all

Ceiling Insulation Details Rafter and Truss Standard Truss with tapered insulation depth 4-inches Note: Wind wash baffle and air-permeable insulation dam. For air permeable insulation in vented attics, baffles shall be installed adjacent to soffit and eave vents. A minimum of a -inch of space shall be provided between the insulation and the roof sheathing and at the location of the vent. The baffle shall extend over the top of the insulation inward until it is at least 4 inches vertically above the top of the insulation. Any solid material such as cardboard or thin insulating sheathing shall be permissible as the baffle. Insulation baffle Insulation Soffit dam (cardboard or rigid foam board) Energy Truss with full height insulation Insulation baffle Insulation 4-inches Soffit dam (cardboard or rigid foam board) Soffit vent Standard rafter and top plate with tapered insulaton depth Insulation 4-inches Insulation baffle Soffit dam (cardboard or rigid foam board) Rafter on raised top plate with full height insulation Insulation 4-inches Minimum -inch depth for insulation baffle Soffit dam (cardboard or rigid foam board) Raised top plate 0 Soffit vent the. It does not cover all