3M Fire Barrier Sealant IC 15WB+

Similar documents
3M Fire Protection Products. Confidence. Even Under Fire. Principal Products Ltd I Ph: I

3M CS-195+ Composite Sheet Product Description

FIRESTOP AND FIRE PROTECTION

Technical Data Sheet. Astro HPE Sealant. UIC of product-type: AFHPE

3M Industrial Masking Tapes

Fire Protection Product Applications by Contractor Trades Through Penetrations & Joints

Firestop and Fire Protection Systems

Fire Protection Products

Marine Fire Wrap General Installation Instructions Cable Penetrations through A0-A60 and B0-B30 Bulkheads and Decks

BROADCAST: M BLOCKS, PLUGS, PLANKS NEW PRODUCT LAUNCH Date: June 16, 2016 Issued by: George Yoshida, Ted Colwell

Promat PROMASEAL Fire Barrier

Fire Barrier Duct Wrap 615+

Endotherme Mat ES-5A-12

3M Fire Barrier Moldable Putty Pads MPP+ Product Data Sheet

Product Catalogue 2017

FIRESTOP SUBMITTAL PACKAGE

3 700-Series Hybrid Products:

SECTION THROUGH-PENETRATION FIRESTOP SYSTEMS

3M Fire Barrier Duct Wrap 615+ Product Data Sheet and Installation Guide (Condensed Version)

BlazeBrake. Fire Protection Systems. Retrofit Fire Rated Devices for Cable & Pipe Services

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: FIRESTOPPING REPORT HOLDER: PASSIVE FIRE PROTECTION PARTNERS

St. Monica Food Pantry

DIVISION 7 THERMAL AND MOISTURE PROTECTION SECTION PENETRATION FIRESTOPPING

Fireban One FIRE RATED SEALANT UP TO 4 HOURS FIRE PROTECTION TO AS ONE PART POLYURETHANE

DECEMBER Phone: Fax:

3M Marine Adhesive Sealant Solutions For Boat Building and Repair. Come sun, wind or. high water

SEALING & BONDING SIKA FIRE PROTECTION SOLUTIONS FOR JOINTS AND PENETRATIONS

A new method for protecting construction joints and through-penetrations from fire, water, smoke and sound.

REGULATORY INFORMATION REPORT

Installation Guide April 2017

Fire stop barriers FIRE - STOP. Fire stop barriers

FIRESTOP 101: An Introduction to Firestopping

3M OEM Polyurethane Glass Adhesive Sealant

BICSI March 19 th, 2009 Canadian Regional Meeting NBCC Moncton, New Brunswick. Firestop, it s not Magic It s understanding!

Product Information High Performance Building Dow Corning Firestop 700 Silicone Sealant

Scotch-Weld TM Polyurethane Reactive Adhesives

The following excerpt are pages from the Firestop Systems Specifiers Guide U.S. Volume 14.

K-FLEX K-FLEX K-FIRE. firestopping solutions

PASSIVE FIRE PROTECTION PRODUCTS

Rainscreen Ventilated Fire Barrier

High Performance Double Coated Tape

Density, Lbs/Gallon

Adhesion Promoter/Primer 3M Adhesion Promoter AP596

FIRESTOPPING. The Hidden Solution that Compartmentalizes. Vic Wootton A/T Firestop and Fireproofing Solutions

Tehnical Data Sheet Astro Intu Mastic. UIC of product-type: INTUM CPR-JA5015

FIRE STOP PRODUCTS. As innovative manufacturers, we are continuously adding to our range, meeting the needs of a highly demanding market.

3M Fire Protection Systems Full Line Brochure. Confidence. in Protecting. Life & Property

Low Odour Acrylic Adhesives DP8805NS Green DP8810NS Green DP8825NS Green. Preliminary Technical Data Sheet May 2017

Intumescent Pipewrap Roll

FIREPRO FIRESTOP PIPE COLLARS. Firestop solution for plastic pipework penetrations

Construction. Adhesive for bonding reinforcement. Product Description. Tests. Product Data Sheet Edition 16 December 2014

Air and Vapor Barrier 3015

CAULKING INSTRUCTIONS GRABBERGARD EFC & IFC

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: DEMILEC (USA) INC.

Scotch-Weld Acrylic Adhesives

Next Generation Structural Acrylic Adhesives. Enhance Productivity and Performance

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: MINERAL FIBER FIREPROOFING REPORT HOLDER: UNIFRAX I LLC

Applications USES FIRESTOP SYSTEM. Fire Barrier Caulk. Smoke and Acoustic Sealant. Moldable Firestop Putty. Putty Pads.

3 Scotch-Weld TM. Bulk Adhesives. General Purpose 60 CA Hi-Strength Laminating 92 Hi-Strength Post-forming 94 CA. Technical Data May, 2008

SEPTEMBER construction type cavity barriers. SP Firestop Systems. The purpose-made solution for cavity fire stopping

4411N 4411G 4412N 4412G

Chemical Name: Manufacturer: Container size: Location: Disposal:

FIRE-RESISTANCE TEST ON FIRE COLLARS PROTECTING A CONCRETE SLAB PENETRATED BY SERVICES

Fire Protection Products. Firestop Submittal Package FIP 1-Step Firestop Foam. Electrical Trade

FIRESTOP SUBMITTAL PACKAGE

CERTIFICATE OF APPROVAL No CF 517 FSI LIMITED

RECOMMENDED APPLICATION INSTRUCTIONS FIRE RETARDANT COATINGS FOR CABLES AND FIRE RESISTANT BARRIERS FOR SERVICE PENETRATION SEALS

FIRESTOPPING Products for Life Safety and Code Compliance

3M Cold Shrink Silicone Rubber Connector Insulators 8440 Series

SECTION THROUGH-PENETRATION FIRE STOP SYSTEMS

3 Scotch-Weld TM. Epoxy Adhesive DP100 FR. Technical Data July, 2011

Scotch-Weld Metal Bonder Acrylic Adhesive DP8407NS Gray

Technical Data Sheet February 2014

3M Fast Tack Water Based Adhesive 1000NF

LISTING INFORMATION OF International Fireproof Technology Inc. - Joint Systems SPEC ID: 43848

Extreme Sealing Tape

Jean Vaillancourt Fire Protection Specialist Hilti (Canada) Corp.

3 Scotch-Weld TM. Epoxy Adhesive 2158 B/A. Technical Data December, 2009

ICC-ES Evaluation Report Reissued May 1, 2010 This report is subject to re-examination in two years.

METACAULK PRODUCT CATALOG

Pyroscat Duct Wrap XL

ESR-2072 Reissued September 1, 2013 This report is subject to renewal September 1, 2015.

3 Fastbond TM. Insulation Adhesive. Technical Data September, 2010

3M Plastic Bonding Adhesive 2665B, Black

Protecting Penetrations in Fire Rated Construction

3 Scotch-Weld TM. Epoxy Adhesive EC Technical Data November, 2010

Silmate RTV1473. Black, One Component, Silicone Rubber

The budget Security expert!

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: DEMILEC (USA) LLC

The Proven Solution Panel Seal Single and double panel penetration seals for cables

CERTIFICATE OF APPROVAL No CF 513 FSI LIMITED

DOWSIL 902 RCS Joint Sealant

FIRESTOP TECHNICAL PACK TEL: (888) 721-SEAL (7325) FAX: (888) 921-SEAL (7325)

3-part thixotropic epoxy patching mortar

3M Spray Adhesives Performance. Productivity. Efficiency. Streamline your assembly operation with convenient, efficient 3M Spray Adhesives.

SECTION HVAC INSULATION

3 Scotch-Weld TM. Epoxy Adhesive DP920. Technical Data October, 2009

CERTIFICATE OF APPROVAL No CF 663 HILTI AG

HILTI FIRESTOP MORTAR CFS-M RG. European Technical Assessment ETA N o 12 / 0101

Transcription:

3M Technical Data Sheet 3M Fire Barrier Sealant IC 15WB+ The 3M Fire Barrier Sealant IC 15WB+ is a latex sealant designed for use as a one-part fire, smoke, noxious gas and water resistant sealant. In addition, the unique intumescent property of this material (expands when heated) means that as the combustible cable insulation is consumed by fire, the sealant expands to maintain the penetration seal. can be installed with a standard or bulk caulking gun, pneumatic pumping equipment or it can be easily applied with a putty knife or trowel. Sealant bonds to gypsum wallboard, concrete, metals, wood, plastic and cable jacketing. No mixing is required. Tool within 5 minutes of application, if required. provides Fire Resistance Ratings of up to 2 hours. Product Features Water Based: Easy clean up, no special handling, routine disposal Intumescent: Expands when heated to maintain seal around items consumed by fire Endothermic: Absorbs heat energy, releases chemically bound water Thixotropic: Will not sag or run in overhead or vertical applications Halogen-free Fast dry: Tack-free in approximately 8 to 12 minutes @ 23 C (73 F) Paintable. Best results obtained after 72 hour cure Minimal shrinkage Yellow colour High flow rate: 2000 g/min. with 6 mm (1/4 ) nozzle Point contact allowed Testing in accordance with AS1530.4, AS4072.1, EN1366, and ASTM E814 (UL Listed).

Physical Properties 2 Typical Physical Properties Tack Free Time (ASTM C679-87) Continuous operating temperature Expansion at 350 C (662 F) 2.0 Colour Density Adhesion Application Durometer Hardness (Shore A) 70 Solids VOC Odour Flow Rate ASTM E 84: Flame Spread Smoke Development Boeing Flow (Sag Characteristics) Availability 8 to 12 minutes @ 23 C (73 F) Up to 48 C (120 F) Yellow 1.43 kg/l (12.0 lb./gal.) Very good on all construction substrates Caulk guns, trowel, spatula, pressurized pumps 80% by weight 0% by weight Pleasant non-irritating 2000 grams/min. from 6.35 mm (1/4") nozzle at 50 psi 0 0 <5.08 cm (2") in 5 minutes 3M Fire Barrier is available from Authorized 3M Fire Protection Products Distributors. Size Packing Unit/Case 300 ml (10.1 fl.oz.) cartridge 12 594 ml (20 fl. oz.) sausage 10 802 ml (27 fl. oz.) cartridge 6 17 litre (4.5 gallon) pail 1 Maintenance is stable under normal storage conditions and has a one year shelf life. Normal stock rotation practices are recommended. Recommended: Store between 4 C (40 F) & 32 C (90 F) for maximum shelf life. Keep from freezing.

Table 1 - Performance Specifications for Installers 3 Australian Standard FRL s Fire Resistance Level (FRL) 3M Fire Barrier System 3M Fire Barrier Sealant IC 15WB+ Building Element Floor: Concrete slab. Minimum 120mm thickness Wall: Plasterboard Dry Wall, solid masonry, hollow masonry or concrete construction. Minimum 116mm thickness Wall: Solid masonry, hollow masonry or concrete construction. Minimum 150mm thickness Blank (Unpenetrated) Seal PVC Insulated Cables, Cable trays and Cable bundles * Copper or Steel Pipes Small 15mm diameter or smaller 0.9mm Wall thickness or thicker * Steel Pipes Small 34mm diameter or smaller 3.5mm wall thickness or thicker * -/120/120 -/120/30 -/120/120 -/120/30 Steel Pipes Large 114mm diameter or smaller 4.5mm wall thickness or thicker * -/120/120 -/120/30 -/120/30 -/120/30 -/120/- In order to achieve the above FRLs you must ensure that the is installed as per the Installation Techniques and the building element you are installing into has an FRL performance equal to or better than that of the IC 15WB+ system. The Installation Techniques can be found on the final page of this document. What does FRL mean? FRL stands for Fire Resistance Level. For example, an FRL of -/120/30 indicates: Structural Adequacy. The first dash - indicates that IC 15WB+ Sealant is non load bearing Integrity. The middle number 120 indicates for how many minutes the IC 15WB+ system can resist the passage of flames and hot gasses Insulation. The last number 30 indicates how many minutes it takes the unexposed face to heat up by more than 140 o C. *Where the FRL of the firestopping system requires an insulation value greater than that given in table 1, the use of additional insulating wraps can be employed - see Appendix A. Metal Pipes 140kg/m 3 140kg/m 3 Dry Wall 150mm Copper: 15mm dia, 0.91mm wall: FRL: -/120/30 Steel: 34mm dia, 3.5mm wall: FRL: -/120/30 Steel: 114mm dia, 4.5mm wall: FRL: -/120/- Solid Masonry, Hollow Masonry or Concrete Wall 150mm Copper: 15mm dia, 0.91mm wall: FRL: -/120/30 Steel: 34mm dia, 3.5mm wall: FRL: -/120/30 Steel: 114mm dia, 4.5mm wall: FRL: -/120/30

Performance Specifications for Engineers and Specifiers 3M Fire Barrier has been tested in accordance with AS1530.4 and assessed in accordance with AS4072.1. The following illustrations provide a summary of the test results for D1 and D2 cable configurations, metal pipe penetrations and blank unpenetrated seals with installed as per the Installation Techniques. Specifications for standard D1 and D2 cable configurations can be found in AS1530.4 Appendix D. 4 D1 Cable Pack Power Transmission Cables. Dry Wall 116mm FRL: -/120/30 Solid Masonry, Hollow Masonry or Concrete Wall 116mm FRL: -/120/30 Concrete Floor 120mm FRL: -/120/30 D2 Cable Pack Telecom Cables. Dry Wall 116mm FRL: - /120/30 Solid Masonry, Hollow Masonry or Concrete Wall 116mm FRL: -/120/30 Concrete Floor 120mm FRL: -/120/30 Blank Openings (unpenetrated) Dry Wall 116mm FRL: -/120/120 Solid Masonry, Hollow Masonry or Concrete Wall 116mm FRL: -/120/120 Concrete Floor 120mm FRL: -/120/30

Installation Techniques: Installation Techniques: Walls Electrical Cables, Blank (unpenetrated) Seals Install mineral wool infill friction fitted and centred in the penetration. Ensure that enough space is left on either side of the mineral wool for the. Install to a depth of 20mm for electrical cables and 25mm for blank unpenetrated seals on both sides of the wall. Ensure that the Sealant is installed flush with the wall on both sides of the penetration. 5 Metal Pipes Install 140kg/m 3 Mineral Wool infill friction fitted and centred in the penetration. Ensure that enough space is left for the. Install to a depth of 25mm on both sides of the wall, ensure that the Sealant is installed flush with the wall on both sides of the penetration. 140kg/m 3 Installation Techniques: Floors Electrical Cables, Blank (unpenetrated) Seals Install mineral wool infill friction fitted into the floor slab, the bottom of the mineral wool should be flush with the bottom surface of the floor slab. Ensure that enough space is left above the mineral wool for the. Install to a depth of 40mm on the top side of the floor slab only; ensure that the Sealant is installed flush with the top surface of the floor slab. 3rd Party Fire Testing to AS 1530.4 & AS 4072.1 To view all current 3M Fire Protection Approvals: www.3m.com.au/fireprotection

Appendix A Insulation Upgrade with 100mm Wrap System 6 100mm flexible wall systems 75mm solid wall systems 30mm Fillet System: Single Cables Diameters up to 20mm 16mm 2 multi-core cable 3M Fire Barrier Packing material PM4 Diameter of 3M IC15WB+, around the cable, at the surface of the wall, must be at least 40mm.

Insulation Upgrade with 150mm Wrap System 7 100mm flexible wall systems 75mm solid wall systems 150mm Wrap System: Cable Bundles Diameters up to 20mm Up to 8 Cables / Bundle 3M Fire Barrier Duct Wrap Collar 615+ System Scotch 8981 Filament Tape as an assembly aid, and Metal Cable Ties, at spacing of 100mm.

Insulation Upgrade with 600mm Wrap System 8 116mm flexible wall systems 116mm solid wall systems 600mm Wrap System: Cable Bundles & Trays & Metal Pipes, as per related Regulatory Information Report ( RIR ) * All diameters and configurations, in accordance with AS 1530.4 and AS 4072.1 3M Fire Barrier Duct Wrap 615+ System Scotch 8981 Filament Tape as an assembly aid, and Metal Cable Bands, at spacing of 200mm.

Insulation Upgrade with 150mm Wrap System Insulation Upgrade with 600mm Wrap System 9 Min 120 mm Concrete Slab Min 120 mm Concrete Slab Mouldable Putty+ Mouldable Putty+ Mouldable Putty Mouldable Putty 150mm Wrap System: Cable Bundles Diameters up to 20mm Up to 8 Cables / Bundle 3M Fire Barrier Duct Wrap Collar 615+ System Scotch 8981 Filament Tape as an assembly aid, and Metal Cable Ties, at spacing of 100mm. 600mm Wrap System: Cable Bundles & Trays All diameters and configurations, in accordance with AS 1530.4 and AS 4072.1 3M Fire Barrier Duct Wrap Collar 615+ System Scotch 8981 Filament Tape as an assembly aid, and Metal Cable Bands, at spacing of 200mm. 3rd Party Fire Testing to AS 1530.4 & AS 4072.1 To view all current 3M Fire Protection Approvals: www.3m.com.au/fireprotection 3M Industrial Adhesives and Tapes Division 3M Australia Pty. Ltd. Bldg A, 1 Rivett Road, North Ryde, NSW 2113 Phone 136 136 (Option 2) Web www.3m.com.au For further information Call: 136 136 User is responsible for determining whether the 3M product is fit for a particular purpose and suitable for user s application. Limitation of Liability. Except where prohibited by law, 3M will not be liable for any loss or damage arising from this 3M product, whether direct, indirect, special, incidental or consequential, regardless of the legal theory asserted, including warranty, contract, negligence or strict liability. 3M and Scotch are a trademark of 3M Company. 3MBDTL0003 BD-2016-12-12