Reuse of greywater and rainwater using fiber filter media and metal membrane

Similar documents
BEING GOOD STEWARDS: IMPROVING EFFLUENT QUALITY ON A BARRIER ISLAND. 1.0 Executive Summary

The Integrated Rainwater and Grey Water Management Project in Cebu, Philippines

Membrane Systems. Featuring Aqua MultiBore Membranes

Reclamation of Sand Filter Backwash Effluent using HYDRAcap LD Capillary UF Membrane Technology

Membrane Filtration Technology: Meeting Today s Water Treatment Challenges

SOFI FILTER Self-cleaning microfilter from 1 µm

Innovating Water Treatment Technologies in Managing Water-Energy Demand

W O C H H O L Z R E G I O N A L W A T E R R E C L A M A T I O N F A C I L I T Y O V E R V I E W

Air Connection on Rack. Filtrate Connection on Rack

Evaluation of Conventional Activated Sludge Compared to Membrane Bioreactors

Quality of Rainwater From Rainwater Harvesting Systems in Sanaa. Nagib Ghaleb N. Mohammed, Civil Engineering Department, University of Bahrain

Potential Reuse of Grey water form Mosques for Toilet Flushing and Garden Irrigation in Saudi Arabia

MEMBRANE BIOREACTORS (MBR)

Case Study. BiOWiSH Aqua. Biological Help for the Human Race. Municipal Wastewater Bathurst Waste Water Treatment Works Australia.

Operation of a small scale MBR system for wastewater reuse

Domestic grey water treatment and recovery to meet up the standards of characteristics of irrigation water

Water Reuse Technology Trains for Medium-level Water and Industrial Cooling Water in South Korea

Characteristics of Nutrient Removal in Vertical Membrane Bioreactors

SPECCO RAINWATER HARVESTING PRODUCTS

Household Greywater Treatment and Reuse Potential in Oman. Abdullah Al Buloshi, Mushtaque Ahmed and S.A. Prathapar Sultan Qaboos University, Oman

POREX Tubular Membrane Filter Modules For Metal Contaminated Wastewater Treatment & Reclamation

Achieving Net-Zero Water

Membrane Bio-Reactors (MBRs) The Future of Wastewater Technology, Science and Economy Aspects

Treatment and Reuse of Tannery Waste Water by Embedded System

DISCUSSION PAPER. 1 Objective. 2 Design Flows and Loads. Capital Regional District Core Area Wastewater Management Program

New prototype prefilter for seawater RO

Use of Spiral Wound UF in RO Pretreatment

Recovery and reuse of water from effluents of cooling tower

DEVELOPMENT OF THE. Ken Mikkelson, Ph.D. Ed Lang Lloyd Johnson, P.E. Aqua Aerobic Systems, Inc.

Water and Wastewater Engineering Dr. Ligy Philip Department of Civil Engineering Indian Institute of Technology, Madras

Sustainability and membrane processing of wastewater for reuse

POLYCERA: A NOVEL ULTRAFILTRATION MEMBRANE PROVIDING OPEX SAVINGS FOR RECLAIMED WASTEWATER APPLICATIONS. Introduction

Executive Summary of a Project on Integrated Stormwater Management System in Cebu, the Philippines

Agenda. Pretreatment Background Typical Contaminants Practical Examples Methods of Treatment and References

Ultrafiltration Technical Manual

Peculiar or unexpected behavior of Silt Density Index of pretreated seawater for RO desalination

Flocculation Flotation Pretreatment Improves Operation of MBR Installed to Treat Snack Food Manufacturing Wastewater

Development of Integrated Filtration System for Water Treatment and Wastewater Reclamation in Developing Countries

SEPARATION OF OIL WATER EMULSION FROM CAR WASHES

TREATMENT OF TOILET WASTEWATER BY MEMBRANE BIO REACTOR TECHNOLOGY

Greywater Recycling PAYS Hotels Schools, Offices Apartment Buildings Sport and Fitness Centres

Advanced water and wastewater treatment technologies in Thailand

Purification of Stormwater Using Sand Filter

Aqua-Recycling-Control 80B Plus

Oklahoma Department of Environmental Quality Water Quality Division. Patty S. Thompson, P.E. Water Pro Conference September 30, 2015

Nutrients recovery of source separated urine by forward osmosis and a pilot scale resources-oriented sanitation system

REACTION TANKS ADVANCED MEMBRANE FILTRATION

Eddie Van Giesen RainCycle Rainwater National Sales Manager. Watts

Wet Detention Ponds, MCTTs, and other Options for Critical Area Stormwater Control. Robert Pitt University of Alabama, Tuscaloosa, AL

Copies: Mark Hildebrand (NCA) ARCADIS Project No.: April 10, Task A 3100

Lowering The Total Cost Of Operation

RECYCLED WATER AT SYDNEY OLYMPIC PARK. Andrzej Listowski SYDNEY OLYMPIC PARK AUTHORITY

Oklahoma Department of Environmental Quality Water Quality Division. Patty S. Thompson, P.E. Southwest AWWA Conference October 14, 2014

SURVEY OF THE FOULING CHARACTERISTICS BETWEEN ATTACHED AND SUSPENDED GROWTH MICROORGANISMS IN SUBMERGED MEMBRANE BIOREACTOR

Using of membrane processed for water treatment in the world

CHEMICAL MONITORING & MANAGEMENT LESSON 6: WATER QUALITY 1 SAMPLE RESOURCES

Technical White Paper

Application of MBR Technology in Municipal Wastewater Treatment

MBR MRI BIO-CEL. Ultra-Effective, Ultra-Filtration. MRI Bio-Cel MBR. Meurer Research, Inc Joyce Drive (303) FAX (303)

TECHNICAL GUIDANCE DOCUMENT APPENDICES

Monitoring Stormwater Best Management Practices: Why Is It Important and What To Monitor

Pilot-Scale Electrocoagulation with Bipolar Aluminum Electrodes for On-Site Domestic Greywater Reuse

Memorandum Neighborhood Development Services Office of the City Engineer City Hall Annex, 610 East Market St., Charlottesville

An Overview of Water Recycling in the United States

OriginClear Water Treatment with Innovative Desalination Techniques High TDS Water Treatment for Oil & Gas Markets in Oman

Keywords nanofiltration; capillary membrane; direct treatment; backflush; surface water.

NEW BIOLOGICAL PHOSPHORUS REMOVAL CONCEPT SUCCESSFULLY APPLIED IN A T-DITCH PROCESS WASTEWATER TREATMENT PLANT

Textile membranes systems as a simple approach to apply reclaimed water for safe reuse application

Membrane bioreactor and promising application for textile industry in Vietnam

Ecosol Rain Tank Maintenance Guide. environmentally engineered for a better future. Ecosol WASTEWATER FILTRATION SYSTEMS

Cloth Media Filter Retrofit Increases Filtration Capacity in Existing Sand Filter Basins of WWTPs in USA

Recent Advances in Membrane Technologies Peter D Adamo, Ph.D., P.E Spring Conference Wilmington, NC April 13, 2015

Syska Hennessy Group J366. Water Conservation in Building Design WCE2015. Daniel H. Nall, PE, FAIA, FASHRAE, LEED Fellow, BEMP, HPDP Date

TABLE B.3 - STORMWATER BMP POLLUTANT REMOVAL EFFICIENCIES

Membranes & Water Treatment

A NEW MEMBRANE FILTRATION PLANT FOR GIRGARRE. Geoffrey Frost. Geoffrey Frost, Principal Water Engineer, Parsons Brinckerhoff Australia P/L

Chapter 6 Cost Estimation

DESIGN AND OPERATION OF A HYBRID RO SYSTEM USING ENERGY SAVING MEMBRANES AND ENERGY RECOVERY TO TREAT SOUTHERN CALIFORNIA GROUND WATER.

Treatment Processes for Potable Water

Stormwater Runoff Water Quality Characteristics From Highways in Lake Tahoe, California

Army Water Reuse Policy A Decision Document

Extending the Service Life of Anti-browning Solutions in Fresh-cut Fruit Processing

Water quality assessment of a wastewater treatment plant in a Ghanaian Beverage Industry

Drinking Water Production Using Moving Bed Filtration

Wisconsin Wastewater Operators Association October 4 th 7 th LaCrosse, WI

Microfiltration of milk with backpulsing

Modutech S.r.l. WDS SEAWATER DROPLET SYSTEM FOR FRESH WATER SUPPLY. Ing. Alessandro Cariani

Overview of Desalination Techniques

Water Recycling and Reuse

Operating parameters influencing Ultrafiltration of organic model solutions

Can MBR Eliminate Additional Disinfection? A Case Study. Ufuk Erdal, PhD, PE, CH2M Jonathan Vorheis, PE, CH2M July 17, 2015

Sulaibiya world s largest membrane water reuse project

5.B Generation of pharmaceutical water Author: Michael Gronwald Co-Author: Dr. Ralph Gomez / Up06

Water / Fluid Treatment Technologies and the Art of Applying Technology to Address Reuse and Recycling Challenges in the Oil and Gas Field

Class Environmental Assessment for Burloak Water Purification Plant Phase 2 Expansion Public Information Centre No.1

Effect of coagulation pretreatment on the fouling of ultrafiltration membrane

Study on Separation of Water and Alumina Fine Particles by Cross-Flow Microfiltration

High-Flux Polymeric Membrane for Industrial Water Separation

Appendix D JWPCP Background and NDN

Putting the Misconceptions to Rest:

Transcription:

Desalination 22 (27) 326 332 Reuse of greywater and rainwater using fiber filter media and metal membrane Ree-Ho Kim a *, Sangho Lee a, Jinwoo Jeong b, Jung-Hun Lee a, Yeong-Kwan Kim c a Construction Environment Research Department, Korea Institute of Construction Technology, 2311 Daehwa-Dong, Ilsan-Gu, Goyang-Si, Gyeonggi-Do 411-712, South Korea email: rhkim@kict.re.kr b Department of Water & Sewerage Policy, Environmental Management Corporation, Environmental Research Complex, Kyungseo-Dong, Seo-gu, Incheon 44-78, South Korea c Division of Environmental and Biological Engineering, Kangwon National University, 192-1 Hyoja-Dong, Chunchon-Si, Kangwon-Do 2-71, South Korea Received 31 July 25; accepted 23 December 25 Abstract As water resources become more limited and waste discharge becomes increasingly problematic, the concept of water reuse is becoming important. Recently, use of greywater and rainwater as alternative water resources has drawn attention. However, lack of useful information on the combined use of greywater and rainwater hinders wide application of these systems. In this study, novel treatment options including lignocellulose filter media and metal membranes were examined to reuse greywater and rainwater in office buildings. Laboratory scale experiments were performed to evaluate the potential of these technologies. The fiber filter media was useful to control first flush rainwater but was not enough to produce water for non-potable use in buildings. Thus, the metal membrane filtration was attempted to reject particulate pollutants. The removal efficiency of various pollutants and the membrane permeability were examined using metal membranes with different pore sizes. Keywords: Fiber filter; Water reuse; Phosphate removal; Building; Rainwater; Wastewater *Corresponding author. Presented at the conference on Wastewater Reclamation and Reuse for Sustainability (WWRS25), November 8 11, 25, Jeju, Korea. Organized by the International Water Association (IWA) and the Gwangju Institute of Science and Technology (GIST). 11-9164/6/$ See front matter 26 Published by Elsevier B.V. doi:1.116/j.desal.25.12.71

R.-H. Kim et al. / Desalination 22 (27) 326 332 327 1. Introduction Water conservation, efficiency and reuse are becoming increasingly important as we now face serious problems including reduced groundwater and surface water levels, drought and changing climate patterns. Sustainable water management systems are based on the principle that water sources should be matched with end uses in terms of the required water quality. The principles of sustainable water management help identify alternative sources of water that can be supplied to meet the water demand in ways that do not require potable water quality [1,2]. Use of greywater or rainwater to substitute non-potable water in buildings is not a novel concept but a powerful tool for sustainable water management [2 5]. Greywater is collected from indoor sources other than toilets such as showers and hand basins. This usually requires treatment such as screening, oil & grease removal, filtration, and disinfection. Rainwater can be collected from the impervious surfaces (such as rooftops and other paved surfaces) of the building premises. Rainwater requires treatment such as sedimentation, filtration, and disinfection. Usually, rainwater collected from rooftops would require less treatment compared with the greywater because it contains fewer amounts of pollutants. However, the quantity of rainwater collected from rooftop highly depends on the weather conditions, climate and has seasonal variations. Thus, it is desirable to use greywater and rainwater in buildings to lower the cost of treatment and to secure enough amount of alternative water resource. Unfortunately, there is little information available on the treatment of greywater and rainwater because few attempts have been done for combined use of greywater and rainwater in buildings. Accordingly, new treatment options using lignocellulose filter media [6,7] and metal membrane filter [8] was investigated in this study to reuse gray water and rainwater in costeffective ways. 2. Methods 2.1. Influent: greywater and rainwater Greywater from cleaning of building floors and rainwater from rooftop were collected and used for the experiments. Moreover, to simulate the combined use of greywater and rainwater, the greywater and rainwater were mixed at 1:1 ratio and also used for the tests. Table 1 summarizes the water quality of the greywater, greywater + rainwater, and rainwater. Fig. 1 illustrates their particle size distributions and the number of particles in each size range. Table 1 Comparison of water quality for greywater, greywater + rainwater, and rainwater Greywater Greywater + rainwater Rainwater ph 7.27 7.36 7.41 EC (ms/cm 2 ) 194 181 187.1 Turbidity (NTU) 12.6 5.9 4.76 Color 49 25 24 COD (mg/l) 22.9 12.5 12.6 Particle count (2 15 mm) 22,495 17,78 257 Total count (ml 1 ) 6 33 49 Total coliform (MPN/1 ml) >2419

328 R.-H. Kim et al. / Desalination 22 (27) 326 332 Accumulated number of particles 25 2 15 1 5 2.2. Fiber filter media Greywater Greywater + rainwater Rainwater 2 4 6 8 1 12 14 16 Fig. 1. Comparison of particle size distributions for greywater, greywater + rainwater, and rainwater. Filtration with lignocellulosic fiber mats has potential to clarify water contaminated by various pollutants. Thus, the possibility for using the fiber filter media was examined here. The fiber filter media made of recycled wood fibers was manufactured in USDA Forest Products Lab. Experiments were performed using both a laboratory-scale device. The devices consist of an initial settling tank and a separation tank containing the filter media (see Fig. 3). Chemical modification of the fiber filter using aluminum oxide was performed to enhance the removal of phosphate and heavy metals. Only rainwater was used for the test of fiber filter media because the primary role of fiber filter media is to treat first flush of rainwater. Concentration (mg/l or NTU) 6 5 4 3 2 1 TN TP Influent Turbidity Mat Fig. 2. Removal of total nitrogen (TN), total phosphate (TP), and turbidity by fiber filter media. outlet Filter media Water flow during the first flush Water flow after the first flush Inlet Setting tank Fig. 3. Schematics of the filtration system using fiber mats. 2.3. Metal membrane Commercially available MMFs (metal membrane filters), supplied by a manufacturing company (FiberTech, Korea), were used for filtration tests. The dimensions and basic characteristics of MMFs are provided in Table 2. 2.4. Analytical methods Spectrophotometric methods of Hach [9] using DR-4 spectrophotometer were adapted to measure the ion concentrations and turbidity. Conductivity and ph were also measured using a conductivity/ph meter and the results were automatically corrected for temperature influence. Total viable bacteria were counted using the Compact Dry Kits provided by Nissui, Japan. The size distribution and number of particles in rainwater samples were analyzed using a particle size analyzer (Malvern Mastersizer/E) and a particle counter (Met One). All tests were duplicated to ensure reproducibility of the results. 3. Results and discussion 3.1. Pollutant removal by fiber filter media The rainwater sample was treated using the fiber filter media at a flow velocity of 11. mm/min. Then, the treatment efficiency of the fiber filter media was examined by analyzing

R.-H. Kim et al. / Desalination 22 (27) 326 332 329 Table 2 Summary of metal membrane filters Parameter 5 mm metal membrane filter 1 mm metal membrane filter.5 mm metal membrane filter Nominal pore radius (r i ) Filter area length (L) Membrane area (A m ) Membrane resistance (R m ) 5 mm 1 mm.5 mm.222 m.222 m.222 m 9.76 1 3 m 2 9.76 1 3 m 2 9.76 1 3 m 2 1.1 1 1 m 1 1.4 1 1 m 1 1.4 1 1 m 1 total nitrogen (TN), total phosphate (TP), and turbidity. As shown in Fig. 2, the removal of TN, TP, and turbidity were 22, 32 and 33%, respectively. It appears that the fiber filter media not only rejects particulate pollutants but also remove soluble ions. The fiber filter media is known to remove contaminants in rainwater through ion exchange mechanisms: Cation exchange reaction occurs for metal removal and anionic exchange occurs for nitrogen and phosphate removal. Twostage filtration, which consists of precipitation and collection on the fiber, also helps to reduce the contaminants from water. 3.2. Incorporation of fiber filter mat into first flush separator Treating the first flush of rainwater is critical for ensuring high quality of water in the storage tank. Thus, the system was designed to selectively filter the first flush of rainwater. Fig. 4 shows how the system behaves under various lengths of inlet gap width and the input flow rate. As shown in Fig. 3, all of the input water will enter into the settling tank and pass through the fiber mat filter when the gap width is large and/or the input flow rate is small. On the other hand, all the input water will bypass the filtration unit at high flow rate of input water. Fig. 4 illustrates the operating modes under different conditions, suggesting that the system can be controlled by Flow rate (ml / s) 25 2 15 1 5.3 Fig. 4. Dependence of operating modes on inlet width and input flow rate. adjusting the size of the inlet width. For instance, the input water overflows the filtration unit over 11 ml/s at.3 cm of the gap width. The flow rate required for total overflow may increase up to 2 ml/s with increasing the gap width to 1.5 cm. This will allow operating the system in an easy and convenient way. 3.3. Metal membrane Overflow Treatment and overflow Treatment.8 1.3 Inlet width (cm) Although the fiber filter media is useful to remove some of the pollutants from rainwater, the quality of produced water was not enough for use in spraying, cleaning, and toilet flushing. Moreover, the greywater contains substantial amounts

33 R.-H. Kim et al. / Desalination 22 (27) 326 332 of particles that cannot be sufficiently rejected by the fiber filter media. It may be possible to apply conventional or advanced filtration techniques such as microfiltration and ultrafiltration but the cost of polymeric membrane systems is substantial and not economically feasible. On the other hand, metal membranes made of stainless steel have potential for this application because of high flux (>1 L/m 2 -h), low cost, long lifetime, and easy operation. Thus, filtration using metal membranes with different pore sizes was attempted to produce high quality of water for non-potable use. Table 3 compares the water quality of influent water and filtrates from metal membranes. Removal efficiency of turbidity ranges from 5 to 75% for greywater and 18 to 54% for rainwater. In case of greywater treatment, metal membranes were also effective to remove pollutants that cause color and COD. Removal efficiency of color was between 5 and 73% and that of COD was between 45 and 7%. On the other hand, negligible amount of color was removed by metal membranes in rainwater tests. Generally, the removal efficiency increases with decreasing nominal pore size of metal membranes. Fig. 5 shows the rejection of particles as a function of their size. Only particles ranges from 2 to 15 mm were considered in this test. In greywater filtration, the pore size of metal membrane was found to affect the rejection significantly. The rejection of 15 mm particles was less than 7% for 5 mm metal membrane fiber while the rejection of same particles by.5 mm metal membranes was more than 95%. The difference in treatment efficiency among metal membranes with different particle sizes became smaller for greywater + rainwater and rainwater cases, as shown in Fig. 5(b) and (c). Based on the results in Fig. 5, it is Table 3 Water quality of influent and filtrates from different metal membrane Panel a Greywater Influent 5 mm 1 mm.5 mm ph 7.27 7.36 7.41 6.81 EC (ms/cm 2 ) 194 181 187.1 163.8 Turbidity (NTU) 12.6 5.9 4.76 3.2 Color 49 25 24 13 COD (mg/l) 22.9 12.5 12.6 6.8 Panel b Greywater:rainwater = 1:1 ph 7.49 7.49 7.51 7.8 EC (ms/cm 2 ) 156.2 14.6 139.9 124.2 Turbidity (NTU) 7.4 2.78 1.96 1.36 Color 15 14 14 11 COD (mg/l) 13.3 5.6 5.4 5.6 Panel c Rainwater ph 7.57 7.52 7.49 7.18 EC (ms/cm 2 ) 82.6 82.4 82.2 87. Turbidity (NTU) 1.19.98.948.55 Color 12 12 12 11 COD (mg/l) 6.1 2.5 2.7 2.

R.-H. Kim et al. / Desalination 22 (27) 326 332 331 Rejection 1..8.6.4.2. (a) Rejection (b) Rejection (c) 1..8.6.4.2. 1..8.6.4.2.. 2 4 6 8 1 12 14 16. 2 4 6 8 1 12 14 16. 2 4 6 8 1 12 14 16 Fig. 5. Rejection of pollutants as a function of their particle size by three metal membranes: (a) greywater; (b) greywater + rainwater; (c) rainwater. likely that the effective pore size of metal membrane seems to be much larger than the nominal pore size. Permeability (L/m 2 -h-kpa) (a) Permeability (L/m 2 -h-kpa) (b) Permeability (L/m 2 -h-kpa) (c) 4 3 2 1 4 3 2 1 4 3 2 1. 5 1 15 2 25 3 35 Time (min). 5 1 15 2 25 3 35 Time (min). 5 1 15 2 25 3 35 Time (min) Fig. 6. Dependence of membrane permeability (defined as the permeate flux divided by transmembrane pressure) on filtration time for three metal membranes: (a) greywater; (b) greywater + rainwater; (c) rainwater. Fig. 6 shows the permeability of metal membranes as a function of filtration time. Here, the permeate was defined as the ratio of flux to

332 R.-H. Kim et al. / Desalination 22 (27) 326 332 transmembrane pressure (L/m 2 -h-kpa). For greywater filtration, 1 mm metal membrane and.5 mm metal membrane show similar decline patterns. However, 5 mm metal membrane shows much slower permeability decline probably because that the membrane rejects fewer amounts of particles in the influent solution. For the mixture of greywater and rainwater, the initial permeability of.5 mm metal membrane was the best but it rapidly decreased with time. After 1 min,.5 mm metal membrane resulted in the smallest permeability. Pore blocking may occur at the beginning of operation for.5 and 1 mm, which causes smaller permeability for.5 and 1 mm metal membrane. Since there was less number of particles in rainwater samples, the permeability of three metal membranes was similar for rainwater treatment. 4. Conclusions In this study, the feasibility of treatment techniques using the fiber filter media and metal membranes were examined for reuse of greywater and rainwater. The following conclusions were drawn: (1) The fiber filter media removed not only particles but also nutrients such as nitrogen and phosphate. The integration of the fiber filter media into first flush treatment unit allowed efficient treatment of rainwater under various conditions. (2) The metal membranes efficiently rejected particles in greywater and rainwater. The metal membrane having larger pore size resulted in slower fouling but lower rejection. It is evident that the treatment of rainwater costs much less than that of greywater. Acknowledgements This research was supported in part by a grant (4-3-1) entitled Practical application of rain-water storage and utilization from Sustainable Water Resources Research Center (SWRRC) of 21st century frontier R&D program and in part by a research grant entitled Basic research projects: Development of Eco-materials to Improve Environmental Properties of Paved Surface from Korea Institute of Construction Technology (KICT). References [1] K.W. Konig, Rainharvesting in Building, Wilo, 21. [2] R.H. Kim, Rainwater utilization for urban establishment of new paradigm, F 41-44, in: A Joint Conference with Korea Society of Water and Wastewater and Korea Society on Water Quality, 22. [3] T.W.D. Board, Texas Guide to Rainwater Harvesting, Texas Water Development Board, Austin, TX, 1997. [4] R.H. Kim, Utilization of ground water and rainwater in urban area, Geoenvironment (21) 217 241. [5] T. Masaru, Strategies toward Building Green Society, Central Law Publishing Co., 22. [6] J.S. Han, Stormwater filtration of toxic heavy metal ions using lignocellulosic materials: selection process, fiberization, chemical modification and mat formation, in: 2nd Inter-region Conference on Environment-Water 99, Lausanne, Switzerland, September 1 3, 1999. [7] R.M. Rowell, Chemical modification of lignocellulosics, in: 223rd National Meeting on American Chemical Society, Orlando, FL, April 3 6, 2. [8] R.-H. Kim, S. Lee, S.-K. Kim and J.-O. Kim, Advanced treatment apparatus and method for rainwater using metal membrane combined with ozonation, submitted to Korean Patent 1-23- 3388, 23. [9] Hach, Hach Water Analysis Handbook, 2nd edn., Hach Company, Colorado, USA, 1992.