ECHO PRESTRESS DURBAN (PTY) LTD HOLLOW-CORE CONCRETE FLOORING A NAME TRULY CAST IN CONCRETE

Similar documents
A NAME TRULY CAST IN CONCRETE PRESTRESSED HOLLOW CORE CONCRETE FLOORS & WALLS

ECHO FLOORS (PTY) LTD HOLLOW-CORE CONCRETE FLOORING A NAME TRULY CAST IN CONCRETE

BISON PRECAST FLOORING SPECIFICATION

HOLLOW CORE FLOORS SPEED AND STRENGTH

PERFECT SLABS Bernie de Klerk

Hollow Core Slabs Applications

Hollowcore Floors. The ideal structural floor solution for all building types in all sectors.

The difference is Guidance for the preparation of Deck Manufacturing Schedules

Inverted Double T BEAMS and SLABS Applications

Shell Beams. Product brochure

Flatslabs. Product brochure

Learning Objectives. A Brief History

ST7008 PRESTRESSED CONCRETE

Portland HOLLOWCORE. The obvious choice

Hollow Core Slabs in Construction Industry

Talk to us, THE SMART DECKING PEOPLE Visit or Global Roofing Solutions Bond-Dek Composite Deck

7.1 Transmission of Prestress (Part I)

Halfen systems for the support and restraint of brickwork

Lattice Plate Flooring

Bridge Beams. Product brochure

Rib and In-fill. Product brochure

Sabah Shawkat Cabinet of Structural Engineering 2017

THE FORENSIC MEDICAL CENTER

Demidec. cornish concrete products Demidec Flooring and Permanent Formwork

DATA SHEET 3 Concrete Masonry Lintels MARCH 2013

Strength Design of Reinforced Concrete Structures

mortarless masonry Design Manual Part 1 (BS 5628:2005) Section 1 Page 1 BS 5628:2005 CODE OF PRACTICE FOR THE USE OF MASONRY

MAHALAKSHMI ENGINEERING COLLEGE

Topic Outline. Two Stage Analysis Procedure: Podium Design. Part 2: Rigid Lower Portion Philip Miller, S.E. 2/8/2018

Lysaght Bondek. Structural steel decking system Design and Construction Manual

Installing DELTABEAM. Installation of DELTABEAM. Deliveries. Storage on-site

Anchor bolts ASTM F1554, Gr. 36 Wide flange beams ASTM A992, Fy = 50 ksi Misc. structural steel ASTM A36, Fy = 36 ksi

POST-TENSIONING APPLICATION AND TECHNOLOGY. Moe Kyaw Aung

WORK BELOW LOWEST FLOOR FINISH 1/7 230, , , FRAME 2/6 96, , ,056.00

cornish concrete products Structural precast

SECTION STEEL DECKING

Structural Floor & Roof Systems

NOTES FOR DESIGNERS AND USERS OF PRESTRESSED PRECAST CONCRETE FLOOR SYSTEMS AND SHELL BEAMS

North Mountain IMS Medical Office Building

HAMBRO COMPOSITE FLOOR SYSTEM

SECTION 1. AS MASONRY STRUCTURES CODE

Statement of Special Inspections Michigan Building Code 2012 (MBC 2012)

Hyperstatic (Secondary) Actions In Prestressing and Their Computation

Do It Right The First Time, Every Time And On Time. An Introduction to HERCULES LMK PT. Website:

Contents. 1.1 Introduction 1

THE PERFORMANCE OF CONCRETE GROUND FLOOR SLAB REINFORCEMENT TO CONTROL SHRINKAGE CRACKING. D H Chisholm 1

Interaction between ductile RC perimeter frames and floor slabs containing precast units

IMPROVING EFFICIENCY AND EFFECTIVENESS IN THE DESIGN, MANUFACTURING AND CONSTRUCTION OF THE BEAM AND BLOCK SLAB SYSTEMS

151 First Side. Technical Assignment 2 November 16 th, William J. Buchko. AE 481w Senior Thesis The Pennsylvania State University

Heavy Rib. Page 1 of 6. Expanded Mesh & Metal Products. Key Product Features:

7. MATERIALS AND TECHNICAL INVESTIGATION

1. Cast-in-place concrete is specified in Section

Proposed Modifications to the LRFD Design of U-Beam Bearings

The bridge over the Georges River at Alfords Point has been duplicated with a new incrementally launched bridge.


Retain "Preinstallation Conference" Paragraph below if Work of this Section is extensive or complex enough to justify a conference.

AISC Steel & Timber Research for High-Rise Residential Buildings

Management of Half Joints in RTA Bridges Amie Nicholas, Project Engineer, NSW Roads and Traffic Authority

The Hashemite University Department of Civil Engineering. Dr. Hazim Dwairi. Dr. Hazim Dwairi 1

System Overview. Beam & Block components. BIM Objects for Beam & Block available to download Forterra.co.uk/bim

SPECIAL INSPECTION AND OBSERVATION PROGRAM CITY OF CONCORD BUILDING DIVISION. Project Address:

Project Address: Name of Person Completing Form:

A. SYSTEM DETAILS A.1 Product Range

mortarless Design Manual Part 1 (AS 3600:2009) Section 1 Page 1 AS 3600:2009 PLAIN AND REINFORCED CONCRETE - CODE OF PRACTICE

CHAPTER 11: PRESTRESSED CONCRETE

Lecture Retaining Wall Week 12

USE OF 500 GRADE STEEL IN THE DESIGN OF REINFORCED CONCRETE SLAB. Prof. M. Shafiul Bari, Ph.D Department of Civil Engg., BUET

Design and Construction of the SH58 Ramp A Flyover Bridge over IH70. Gregg A. Reese, PE, CE, Summit Engineering Group, Inc.

INTERNSHIP REPORT GOUTHAM.J

Composite / Veneer Units. Precision...1. Split Face... 2

Table of Contents.2. Introduction...3 Gravity Loading and Deflections..4. Existing Structural System..8

A.C. Roof Trusses POSI-JOIST TM STEEL WEB SYSTEM

Contents. Tables. Notation xii Latin upper case letters Latin lower case letters Greek upper case letters Greek lower case letters. Foreword.

Comparative Study on Post - Tensioned and Reinforced Concrete flat Slab Systems for a Multistory Building

SECTION NON-STRUCTURAL METAL FRAMING

5.4 Analysis for Torsion

ALLOWABLE STRESS DESIGN OF CONCRETE MASONRY LINTELS. TEK 17-1C Structural (2009) Related TEK: Uniform load. Triangular load. Concentrated loads

Schöck Isokorb type CV

TCC Systems. Timber-Concrete Composite TIMBER IMAGINEERING INNOVATIVE TIMBER SOLUTIONS

CONCRETE MANUFACTURERS ASSOCIATION - MEMBERSHIP LIST

Structural Technical Report 1 Structural Concepts / Structural Existing Conditions Report

***************************************************************************************************************

155 & 220 Beam Flooring Systems

Over the years, the use of precast concrete has taken giant

COST EFFECTIVE BUILDING SYSTEMS FOR RAPID CONSTRUCTION IN TROPICAL CLIMATES

DESIGN FOR PROGRESSIVE COLLAPSE 1

Pro-Con Structural Study for Alternative Floor Systems October 27, 2004

2012 IBC/2011 MSJC MASONRY CODE COMPILATION

Civil Engineering Construction Chapter 5

VTU EDUSAT PROGRAMME Lecture Notes on Design of Stair cases

Locrete Building System: the Technology Handbook

SECTION 1 INTRODUCTION TO POST-TENSIONED CONCRETE DEVELOPED BY THE PTI EDC-130 EDUCATION COMMITTEE

WARMFLOOR. Installation Guide.

SECTION STRUCTURAL PRECAST HOLLOW CORE SLABS

Structural Technical Report #2 Pro/Con Study of Alternate Floor Systems

Prestressed Concrete Girder Continuity Connection

BrD Superstructure Tutorial

FORMDECK. constructions. constructions

A Composite Structural Steel and Prestressed Concrete Beam for Building Floor Systems

Structural Technical Report 1 Structural Concepts / Existing Conditions

Transcription:

ECHO PRESTRESS DURBAN (PTY) LTD HOLLOW-CORE CONCRETE FLOORING A NAME TRULY CAST IN CONCRETE

INTRODUCTION TO ECHO PRESTRESS In today s world of innovation and fast tracking, the Echo Prestress hollow-core slab system is the preferred flooring solution. Besides the obvious advantages of simpler, faster construction, not to mention a more durable end product, the secret of applying the flooring solution successfully is in the pre-planning. Get Echo Prestress involved at the concept stage. The Echo Group of companies has a track record spanning 30 years in S.A. and more than 60 years in Europe. Make use of our advice and design input it comes at no charge and is guaranteed to result in an overall cost saving. Set out in this brochure are several examples demonstrating the versatility and multi-purpose functionality of the prestressed hollow-core slabs. Applications covered include floors, security walls, reservoir roofs, retaining walls and warehouse walling, multistorey floor applications to residential, coercial and industrial buildings, as well as suspended ground floor slabs in clay areas and a foundation system for social housing. Services offered: Echo Prestress provide: Lining, levelling and grouting services. Echo provide an engineer s certificate for the floor slab only. The design is done in accordance with SANS 10100-1 and SANS 10100-2. Typical applications of Echo Prestress Medium rise load-bearing masonry structures Cathedrals Residential Coercial Offices Townhouses Educational Institutions Affordable Housing Industrial 2

DESIGN OVERVIEW Structural Details 1 2 3 Manufacturing method Slab depths available Temporary support 4 5 6 Standard slab widths available Non-standard widths available Product weights kg/m2 7 imum recoended characteristic strength of concrete at transfer. * Clause 5..1 of SANS 10100-1Ed 2.2 shall apply imum recoended characteristic strength of concrete at 28 days. * Clause 5..1 of SANS 10100-1Ed 2.2 shall apply Recoended limits on span/depth ratios for hollow core slabs. 8 9 Prestressed / slipformed 120, 150, 170, 200, 250 Generally no temporary support required except for special applications and / or design requirements. 1200 Manufactured in 100 increments Slab depth Slab only Slab & joint Slab, joint & 40 screed 232 kg/m2 332 kg/m2 120 217kg/m2 150 249 kg/m2 266 kg/m2 366 kg/m2 170 275 kg/m2 292 kg/m2 392 kg/m2 200 298 kg/m2 320 kg/m2 420 kg/m2 250 350 kg/m2 420 kg/m2 520 kg/m2 35MPa for 120, 150, 170 and 200 deep slabs. 45MPa for 250 deep slabs 50MPa for all slab depths. For roof slabs a span to depth ratio limit of 50 is suggested. For floor slabs a span to depth ratio limit of 45 is suggested. Note: When, 1) fire endurance, 2) openings, or 3) sustained live loads do not control the design. 10 Prestressed reinforcement Wire: Tripple indented low relaxation Strand: Stabilized 9.3 and 1 180minutes 11 Fire resistance level (FRL) of a floor is specified in the building Structural adequacy: Integrity: 90minutes codes as the period in minutes during which the floor must 90minutes retain its: * Clause 7.3 of SANS 10100-1Ed 2.2 Table 46 - Fire Resistance Insulation: of Prestressed Concrete Floors shall apply 12 Suggested slab bearings 13 Cantilevers 14 Weight saving 15 Higher strength materials (both for concrete and steel) 16 Hollow core slab deflections Total deflection is defined as the upward camber of the slab due to the eccentricity of the pre tensioning less the downward deflection due to applied loads, including the long term effects of prestress loss, creep and shrinkage. 17 Service holes 18 Service holes larger than 90 On brickwork 100. On steel and concrete 75 Suggested cantilevers are limited to the following: 120 1 080 200 1 500 150 1 350 250 1 875 170 1 360 30% lighter than a solid slab of the same depth. The higher strength steel is tensioned and anchored against the concrete which produces a number of desirable effects: The prestressing tends to neutralise tensile stresses and strains induced by the load. The full concrete section becomes active in resisting the load. Higher strength concrete may be used to obtain a more economical hollow-core section, than with reinforced concrete. Final long term deflection Span / 250 Variable long term live movement Span / 500 Overall long term movement Span / 500 Up to 90 may be made in the panel on site. Should be referred to the design engineer and should be formed by Echo in the factory. These holes require more specific strengthening. 3

DESIGN OVERVIEW CONTINUED Structural Details continued 19 Skylight and stair openings 20 Open cores 21 Angled cuts 22 Installation 23 Grouting 24 Levelling screed / structural topping Not included in the Echo price, specifications available from Echo. 25 Soffit / ceiling finishes 4 Are formed by specifically fabricated steel hangers which are supplied and erected by Echo. (Refer to the sketch below) The tops of the hollow-cores can be opened to take steel when slabs are used in composite action with steel or concrete beams Angled / skew ends can be cut in the factory with a diamond tipped saw blade specifically manufactured to accurately cut an angle. This service is provided by Echo and included in the price. This service is provided by Echo materials supplied by the contractor/ client. Suggested 40-50 thick but note that in some areas additional screed may be necessary to level the positive camber in the units resulting in a thicker screed at the ends of the slab. Specifications available from Echo.

LOAD / SPAN TABLES In addition to the superimposed load shown, these tables include an allowance for the self weight of the unit and for levelling screeds and finishes. The details provided below are basic should in depth design details be required, refer to www.echo.co.za click on Echo Prestress Technical Details - Load / Span Tables 120 Kg/m2 120 217 Kg/m2 150 249 Kg/m 170 275 Kg/m2 200 298 Kg/m2 250 350 5.5 5.1 4.6 4.4 4.1 3.9 3.4 6.2 5.8 5.3 5.1 4.7 4.5 3.9 3.6 150 6.3 5.8 5.3 5.1 4.7 4.4 3.9 3.5 8.2 7.6 7.0 6.8 6.3 6.0 5.3 4.8 170 5.4 6.1 5.6 5.4 4.7 4.2 3.7 9.2 8.7 8.0 7.7 7.2 6.8 6.0 5.5 2 200 7.2 6.7 6.1 5.9 5.5 5.2 4.6 4.2 9.7 9.1 8.4 8.1 7.6 7.2 6.4 5.9 250 9.4 8.8 8.1 7.8 7.3 6.9 6.2 5.6 13.3 12.6 11.7 11.3 10.6 10.1 9.0 8.2 Standard Slab Section Slab s 120 A - 120 B - 60 150 A - 150 B - 90 170 A - 170 B - 110 200 A - 200 B - 140 250 A - 250 B - 190 5

COMPOSITE CONSTRUCTION Introduction The term composite refers to structures where prestressed slabs and in-situ concrete work together to form an integral structural component. The prestressed slab can be made composite with supporting beams to increase the overall structural depth of the supporting beams. Design synopsis As in any composite structure, the design principal is to bond separate elements together to form one element which by virtue of shear interaction is considerably stiffer than the two elements acting individually. In the case of prestressed hollow-core concrete panels and concrete support beams this shear interaction is provided by steel stirrups projecting above the surface of the beam and transverse shear steel, which facilitates the transfer of the forces between the slab and the beam. Precast beam design in composite action with prestressed slabs The design of these spine beams have to be optimized to minimise the depth below the soffit of the slabs. This can best be achieved by the design of the beam as a T-beam in its final stage. To achieve this it is necessary to combine the precast floor slab with the precast /in-situ or steel beams. 6

ALTERNATIVE APPLICATIONS Foundation system for Social Housing The Concrete Manufacturers Association is the Agrément Certificate holder for the hollow-core foundation system. Echo Prestress has been issued with the licence for the system. The certificate covers the Echo building foundation beams for use in all areas of South Africa in non-standard foundation systems of the type referred to in the Certificate, and on sites with founding conditions classified as Class C or H. The beams are to be used in foundations supporting single storey buildings of maximum plan size 6.6 x 6.2m with the foundation beam length in the 6.2m direction. A split Echo Prestress slab used on edge as a ground beam The trench is back filled and compacted Security Walls Hollow core slabs are placed onto the ground beams and then grouted. Hollow ends filled on site by the contractor. Retaining walls Vertical Application Echo Prestress retaining walls are coonly used instead of in-situ walls. Time and cost saving are a major advantage in addition to high quality and concrete strength. Each retaining wall is specifically designed to suit the project requirements. The foundation requirements also differ from project to project. Consult Echo Prestress at early design stage. Echo hollow-core security walls are designed for high end security requirements. Each job is designed to suit specific requirements and can be used vertically or horizontally. Reservoir roofs Horizontal Application The retaining slabs are installed into the flanges of steel or concrete columns. The retaining walls of this structure were designed to withstand very high horizontal forces from within the building. This is a potato storage facility 7

Echo Prestress Durban (Pty) Ltd Part of Echo Group of Companies Hollow-Core Concrete Floors Off Nandi Road North, Effingham PO Box 40726, Redhill, Durban, 4071 Tel: 031 569 6950 Fax: 031 569 6974 Email: echokzn@echo.co.za Web: www.echo.co.za GPS: 29 46 10.6 S, 30 59 42.1 E LASTING VALUE OF CHOICE Echo Prestress Durban reserves the right to alter or change any of the details contained herein without prior notice. Echo Prestress Durban 2014. Design and print Gartone Press. First Issued 26/03/2014