Michelle D. Beason, PE National Plant Services, Inc.

Similar documents
PIPE USERS GROUP (PUG) July 11, Michelle Beason, PE Regional Manager National Plant Services, Inc., a Carylon Company

Service Lateral Rehabilitation Using Cured-In-Place-Pipe (CIPP)

Product Information. Polyester Felt Cured-In-Place Pipe (CIPP) Lining Tube

Cured-in-Place Pipe (CIPP) for Pressure Pipe. Presented by: Mike Moore

EVALUATION SUBJECT: HAMMERHEAD CURED-IN- PLACE PIPE (CIPP) LINING SYSTEM DIVISION: PLUMBING SECTION: SANITARY WASTE AND VENT PIPING

Method One: Liner/Bladder Assembly-Inversion Method.

TRELLEBORG PIPE SEALS. The MtH- Story. Trelleborg Pipe Seals Establishes MtH System Internationally

CIPP Lateral Renewal Connection System

PIPE REHABILITATION. Comply with Division 1 - General Provisions and Covenants, as well as the following:

UNIFIED FACILITIES GUIDE SPECIFICATIONS

Infiltration and Inflow. Michael Sassaman Phone

Inland Pipe Rehabilitation. August 17 OAWWA Canton, OH

Pipe Grouting Longevity Effectiveness Evaluation

EVALUATION SUBJECT: PERMA-LATERAL PULLED- IN-PLACE CURED-IN-PLACE PIPE LINING SYSTEM

MS-2A LINER SPECIFICATIONS: for STRUCTURAL REPAIR and SEALING of MANHOLES

Infrastructure Point Repair System Technical Specifications

INLINER LAY_InLiner Brochure_FA_ indd 1

The Rehabilitation of Existing Building Drains and Building Sewers by the

Protective Coatings for Underground Utility Concrete Structures. By: John E. Davis Inside Sales & Marketing Specialist: Sauereisen, Inc.

r.tec GmbH The technology provider of the Rabmer Group

ENGINEERING DESIGN GUIDE FOR REHABILITATION WITH CURED-IN-PLACE PIPE Second Edition

Installation Practice InnerSeal

SECTION XXXXX CHEMICAL GROUTING

Lateral connection seals for Würzburg

Rehabilitation of the Coral Gables Wastewater Collection System

OTEC 2017 Spray Applied Pipe Liner Supplemental Specifications 833 Calculations for the Resin Based Liner Presented by Peter Blais, PE

until: 20 July 2017 DIBt Kolonnenstrasse 30 B D Berlin Tel.: Fax:

Structural Testing of Geopolymer Pipe & Culvert Mortar Lining System

ESTABLISHING OBJECTIVE TEST PROTOCOLS FOR THE QUANTIFICATION OF WATER-TIGHTNESS OF A REHABILITATED MAIN/LATERAL SEWER CONNECTION

CURED-IN-PLACE PIPE LINING

THE SPECIALIST FOR NO DIG REHABILITATION

Numerical analysis of stresses for cured-in-place-pipe linings

CEDAR RAPIDS METROPOLITAN AREA STANDARD SPECIFICATIONS FOR PUBLIC IMPROVEMENTS May 2014 SECTION SEWER LINERS

Technical Information: Standard Inverted and Pull-In CIPP

THE COMPLETE NO-DIG PIPELINE REHABILITATION SOLUTION

SSO- WDR Compliance Workshop Electronic Reporting: Reporting Requirements & Tips. Sewer System Management Plan Chapter

A. ASTM C 150 Standard Specification for Portland Cement. B. ASTM C 595 Standard Specification for Blended Hydraulic Cements.

RENOVATION OF LARGE DIAMETER PIPES & CHAMBERS

LATEST ADVANCES IN PIPELINE RENOVATION WITH FIBER REINFORCED POLYMER (FRP)

Appendix A EXAMPLE COLLECTION SYSTEM PERFORMANCE INDICATOR DATA COLLECTION FORM

Design Considerations for Selection of Pipe Material for Large Diameter CSO Force Main

Improved Inflow & Infiltration (I&I) Monitoring Program

17/03/2017 CONTENTS. Real Cases Studies in the Region for Pipelines Inspection & Rehabilitation. Introduction CONTENTS. Introduction / Cont.

Streamlining I/I Repairs in Berlin Charter Township

Styrene Free Structural Liner for Sewers and Culverts

CITY OF FARGO SPECIFICATIONS PIPE AND MANHOLE REHABILITATION

ULTRAVIOLET LIGHT CIPP LINING OF EXISTING SEWERS

ASSET MANAGEMENT PROGRAM

ARE TREE ROOTS DAMAGING YOUR PIPES & DRAINS?

CIPP LINER THICKNESS CHANGES UNDER F b

FOREWORD PART 1 - GENERAL. A. Requirements for surface preparation, repairs and 100% Solids epoxy coating application to specified surfaces.

QuakeWrap, Inc. Pipe Repair October 2012

Section SANITARY SEWER SYSTEM REHABILITATION

1. B16.1 Cast Iron Pipe Flanges and Flanged Fittings, Class C 111 Rubber Gasket Joints for Ductile Iron Pressure Pipe and Fittings

SPECIAL SPECIFICATIONS UV CURED IN-PLACE SPIRAL WOUND FIBERGLASSS PIPE LINING

SECTION 806 MANHOLE REHABILITATION

City of Grosse Pointe Park Sanitary Sewer System Inflow and Infiltration Investigation Smoke Testing

SAN ANTONIO WATER SYSTEM 2013 REHABILITATION WORK ORDER CONSTRUCTION CONTRACT 4 SAWS Job No SAWS Solicitation No.

Wastewater Flow Monitoring Services

TECHNICAL SPECIFICATIONS FOR MANHOLE REHABILITATION

TAMDID PIPES GRP MANHOLE BROCHURE

Table of Contents. Page Title Sheet and Index Project History and Summary Work Summary Overview 3-7

Non-styrenated CIPP: A Sure Bet at the Greektown Casino

Madewell Products Corporation December Industrial Court Alpharetta, GA Office: (770) Fax: (770)

Chapter 8 Addressing I/I Issues and High Flows

Rehabilitation of Lafayette Aqueduct No. 1

SECTION 802 GRAVITY SEWER PIPE

Triple Wall and Double Wall Polypropylene Pipe-Joint Infiltration Tests

GENERAL REQUIREMENTS AND TECHNICAL SPECIFICATIONS

Pipeline Condition Assessment. The Essential Engineering Step in the Asset Management Process

TYPICAL PHYSICAL STRENGTH PROPERTIES OF PRO TILE

Agenda. Streamlining I/I Repairs in Berlin Charter Township.. Innovative Techniques

LANE ENTERPRISES, INC. STANDARDS & SPECIFICATIONS

Pipeline Rehabilitation

DESIGN OF SEWER SYSTEMS

Greene Township Municipal Authority Act 537 Plan Update Amendment

This policy will generally explain the following in regards to the City sewerage collection systems:

SECTION RESINOUS FLOORING or SECTION QUARTZ FLOORING

h Sewer Pipe Systems

QUADEX SEWER STRUCTURE RESTORATION MATERIALS INSTALLATION SPECIFICATION

TRENCHLESS WATER MAIN REHABILITATION DESIGN CONSIDERATIONS. V. Firat Sever PE, PhD Project Manager and Senior Engineer. August 28, 2014 Columbus, Ohio

STRUCTURAL CEMENTITIOUS LINER PERMACAST BY AP/M PERMAFORM

SECTION HYDRAULIC CEMENT UNDERLAYMENT

PROCESSING COMBINED LASER, SONAR AND HD IMAGING FOR BETTER EVALUATION DECISIONS

SANITARY SEWER CHEMICAL GROUTING

Top Performance Pipes for Toughest Conditions

TRENCHLESS TECHNOLOGY. Department of Civil Engineering.

TECHNIQUES, MATERIALS AND DESIGN CONSIDERATIONS: REHABILITATION & STRENGTHENING OF WATER AND WASTEWATER PIPELINES. Solutions & Case Studies

Section VI - Trenchless Installations and Rehabilitation

BKP Berolina Polyester GmbH & Co. KG. Berolina-Liner System Lightspeed in gravity pipe rehabilitation!

Scoring Groundwater Infiltration & Sewage Exfiltration Risk in a Sanitary Sewage Collection System. Meredith S. Moore Advisor: Dr.

SECTION XXXX POLYMER CONCRETE PUMP STATIONS

SECTION 7 SEPARATION OF WATER MAINS AND SANITARY SEWERS

NORTH HARRIS COUNTY REGIONAL WATER AUTHORITY. Section DUCTILE IRON PIPE AND FITTINGS

TOWN OF BEEKMAN DOVER RIDGE WATER AND SEWER SYSTEMS. Overview and Recommendations

FOREWORD PART 1 - GENERAL

Review & Design of the Apia Pressure Sewer System

MANAGING DROUGHT IMPACTS ON WASTEWATER COLLECTION SYSTEMS

GREEN THREAD Piping Systems

RESEARCH FACILITIES AND EQUIPMENT

Transcription:

8th Biennial HWEA Collection System Conference Michelle D. Beason, PE National Plant Services, Inc. Honolulu, HI December 4, 2015

CLEANING INSPECTION REPAIR LARGE AND SMALL DIAMETER PIPE CLEANING ROOT REMOVAL WWTP CLEANING SERVICES LATERAL AND MAINLINE CCTV INSPECTION MULTI-SENSOR INSPECTIONS MANHOLE INSPECTIONS LATERAL LINING CENTRIFUGALLY CAST STRUCTURAL COATINGS GROUTING CIPP POINT REPAIRS

Copyright ICOMMM Inc. 2008 ALL RIGHTS RESERVED Courtesy of King County Department of Natural Resources and Parks

Estimate Base Sanitary Flow: 1. Flow Meter Data, 2. From metered water consumption Estimate Infiltration: During seasonal high groundwater (after rainy season), infiltration will be at its highest. Average the nighttime flows over several days, during otherwise dry weather conditions. Estimate Inflow: The Influence of wet weather calculated by subtracting out the sanitary wastewater and infiltration, from the flows produced during a rain event. US EPA, Guide for Estimating Infiltration and Inflow, June 2014

What Methods Can I Use to Determine I&I? US EPA, Private Sewer Laterals, June 2014

What is the Typical I&I from Laterals? Sanitation District No. 1 of Northern Kentucky, Inflow and Infiltration from Private Property, 2006. Water Environment Federation, 1999. Control of Infiltration and Inflow in Private Building Sewer Connections.

Problems Addressed with Service Connection Rehabilitation Inflow / Infiltration Root Blockages Hydraulic overloading Fewer Home Owner Complaints

Service Connection Lining Before After

EPROS TRELLEBORG SYSTEM LCR (Lateral Connection Repair) MTH (Main to House)

LCR (Lateral Connection Repair) MTH (Main to House) LCR No Cleanout required! Full wrap in main, 18 to 2 ft into lateral Uses Silicate Resin Ambient cure of 70 Minutes Uses Inversion process MTH No Cleanout required! Full wrap in main, line lateral up to house 98 ft Uses Epoxy Resin Steam cure of 40 minutes Uses Inversion Process

LCR System Either a hat profile or full circumferential liner Typical length into lateral is 2 ft. Pipe Size: Mainline up to 20, Lateral Size 4-10 Liners are made of a needle fleece comprising 85% ECR fiberglass (Corrosion Resistant Glass) and 15% polyester fiber with a Thermoplastic Polyurethane (TPU) Coating Ambient cure silicate resin (winter and summer type)

Silicate Resin Advantages No VOC s, no styrene no environmental issues or potential health concerns No unpleasant odors Ambient Cure -Excellent potlife and cure times for small diameter installations Cures in the presence of water does not wash out. Zero Shrinkage! Excellent bonding to a wide range of materials

MTH System Circumferential liner up to the building. Maximum length up lateral is 98 ft. Pipe Size : Mainline up to 20, Lateral Size 4-10 Liners are made of a needle fleece comprising 85% ECR fiberglass (Corrosion Resistant Glass) and 15% polyester fiber with a Thermoplastic Polyurethane (TPU) Coating Hot cure epoxy Resin

Epoxy Resin (Epropox HC120) Advantages No VOC s, no styrene no environmental issues or potential health concerns No unpleasant odors Hot Cure - Potlife of 120 minutes at 70 degrees F. Cure time of 45-60 minutes at 176 degrees F. Cures in the presence of water does not wash out. Zero Shrinkage! Excellent bonding to a wide range of materials

ADVANTAGES 85/15 fiberglass liner with TPU coating ensures excellent chemical resistance, high mechanical values, and steam resistance Both silicate and epoxy composites with 85/15 liners exceed the minimum requirements as per ASTM F1216 & F2561. Property ASTM Test Minimum Value Silicate Resin w/85/15 liner Epoxy Resin with 85/15 liner Flexural Strength D790 4,500 psi 11,531 psi 23,583 psi Flexural Modulus D790 250,000 psi 375,213 psi 698,937 psi

INSTALLATION EQUIPMENT Push Rod Spool Packer Stand Control Unit Packer Assembly

INVERSION PROCESS Position the packer until the pathfinder engages into the opening of the lateral connection. Make sure the LCR packer takes a center position with the lateral opening. Set the pressure regulator to an inflation pressure of 10 psi. At first, the pressure is built up in the main pipe. Then pressure will be built up in the lateral connection thereby causing the inversion process to start.

Top 10 Reasons To use lateral lining to reduce your I&I issues!

#10 Epoxy Resin & Resin Migration No Polyester Resin & No Shrinkage & No Annular Space

#9 Use of Calibrated Wet Out Table

WE DO NOT IMPREGNATE OUR LATERAL LINER ON THE GROUND!

#8 Vacuum Impregnation

#7 EPROS liner material has no field connections. Stitched in Factory Conditions. No Field Seams. Other Systems May Glue the liners together in the field to achieve the desired length prior to installation leading to potential week spots in the lining system.

#6 Steamed Cured Resulting in Higher Quality Liner and Decreases curing time (40 minutes) to minimize homeowner inconvenience.

#5 NO CLEANOUT NEEDED! And Capability of Liner Lengths of up to 98 feet from the main.

#4 Capable of inverting lateral lines from mainline sewer diameter up to 20 in Diameter.

#3 Our MTH Lateral Lining System has a proven success rate. Please refer to our testimonies and case studies

#2 - VALUE #1. Eliminate Infiltration Save Money #2. Eliminate Exfiltration Satisfy EPA #3. Structural Repair With No Digging #4. Installing an Asset by extending the life of the infrastructure by 50 + Years

#1 The Price Make Sense! At approximately $2,000 to $3,500 per lateral you can start implementing a long term plan to implement a trenchless rehabilitation program and line every lateral in your collection system. Essentially eliminate infiltration and extend the life of your aging infrastructure.

Questions? Michelle Beason, PE mbeason@nationalplant.com 925-262-7366