Evaluating and Modelling the Effect of Carbon Fiber Grid Reinforcement in a Model Asphalt Pavement

Similar documents
Assessment of the Interface of Overlay and Stess Absorbing Membrane Interlayer (Sami) Using Pull-Off Test

RESILIENT INFRASTRUCTURE June 1 4, 2016

PREVENTION OF REFLECTIVE CRACKING - THE SUCCESSFUL USE OF POLYESTER ASPHALT REINFORCEMENT GRIDS

Finite Element Analysis of RC Beams Strengthened with FRP Sheets under Bending

Spectrum of Axles Approach

INNOVATIVE FIBRE REINFORCED BRIDGE DECK MODULES ABSTRACT

WE RE KNOWN FOR OUR STRENGTH

Advanced Characterization Testing of the Port Authority of NY/NJ s Hot Mix Asphalt Materials

MECHANICAL CHARACTERIZATION OF SANDWICH STRUCTURE COMPRISED OF GLASS FIBER REINFORCED CORE: PART 1

In-plane testing of precast concrete wall panels with grouted sleeve

INNOVATIVE HYBRID WEARING SURFACES FOR FRP BRIDGE DECKS

Asphalt Pavement Aging and Temperature Dependent Properties through a Functionally Graded Viscoelastic Model, Part-II: Applications

Finite Element Modelling of Asphalt Concrete Pavement Reinforced with Geogrid by Using 3-D Plaxis Software

Seismic Retrofit Of RC Columns With Inadequate Lap-Splice Length By External Post-Tensioned High-Strength Strips

EXPERIMENTAL STUDY ON DOUBLE LAP JOINTS COMPOSED OF HYBRID CFRP/GFRP LAMINATE

Explanation of Top-Down Cracking

Experience with Testing and Performance Evaluation of Bituminous Plug Expansion Joints on Concrete Road Bridges

FLEXURAL IMPROVEMENT OF PLAIN CONCRETE BEAMS STRENGTHENED WITH HIGH PERFORMANCE FIBRE REINFORCED CONCRETE

STUDIES ON MARSHALL AND MODIFIED MARSHALL SPECIMENS BY USING CRMB

Laboratory Evaluation of Honeywell Polymer vs SBS Polymer Modified Asphalt Mixtures

Rutting Evaluation of Dense Graded Hot Mix Asphalt Mixture

Performance of NSM FRP strengthened concrete slabs at low temperatures

REVIEW ON SHEAR SLIP OF SHEAR KEYS IN BRIDGES

Parametric Study on Geogrid-Reinforced Track Substructure

DESIGN GUIDELINES FOR BRIDGE DECK SLABS REINFORCED by CFRP and GFRP

Laboratory Testing of Vancouver HMA Mixes Containing Recycled Asphalt Shingles

STRENGTHENING STEEL-CONCRETE COMPOSITE BRIDGES WITH HIGH MODULUS CARBON FIBER REINFORCED POLYMER (CFRP) LAMINATES

BEHAVIOR OF REINFORCED CONCRETE BEAM WITH OPENING

On vibration mode of pultruded FRP sheet piles

Ultimate strength prediction for reinforced concrete slabs externally strengthened by fiber reinforced polymer (FRP)

Simplified Testing Method for Evaluation of Asphalt Mixtures for their Susceptibility to Permanent Deformation

BEHAVIOR OF FRP SANDWICH PANELS FOR TRANSPORTATION INFRASTRUCTURE

Department of Civil Engineering, UIT, RGPV, Bhopal, India

Structural Requirements of Bituminous Paving Mixtures

Fatigue Performance of Precast FRP-Concrete Composite Deck with Long Span

Product Guide Specification

Structural Behaviour of Sandwich Panels Constructed of Foam Cores and Flax FRP Facings

FE MODELING OF CFRP STRENGTHENED CONCRETE BEAM EXPOSED TO CYCLIC TEMPERATURE, HUMIDITY AND SUSTAINED LOADING

Design Methods of Elements from Cross-Laminated Timber Subjected to Flexure

SHEAR PERFORMANCE OF RC MEMBERS STRENGTHENED WITH EXTERNALLY BONDED FRP WRAPS

Experimental investigation of the use of CFRP grid for shear strengthening of RC beams

Deflection of GFRP RC Beams

SMA with Special Modified Asphalt Aimed to Extend Pavement Lifespan

Effects of fiber reinforcement on the fatigue and rutting performance of asphalt mixes

Nonlinear Analysis of Shear Dominant Prestressed Concrete Beams using ANSYS

Pavement reinforcement

Nonlinear Finite Element Analysis of Composite Cantilever Beam with External Prestressing

AXIAL TESTING OF CONCRETE COLUMNS CONFINED WITH CARBON FRP: EFFECT OF FIBER ORIENTATION. Abstract

Strengthening of Reinforced Concrete Beams using Near-Surface Mounted FRP Mohamed Husain 1, Khaled Fawzy 2, and Mahmoud Nasr 3

DYNAMIC RESPONSE ANALYSIS OF THE RAMA 9 BRIDGE EXPANSION JOINT DUE TO RUNNING VEHICLE

CHAPTER 5 FINITE ELEMENT MODELLING

THE EFFECT OF FATIGUE LOADING ON BOND STRENGTH OF CFRP BONDED STEEL PLATE JOINTS

CRACKING BEHAVIOR AND CRACK WIDTH PREDICTIONS OF CONCRETE BEAMS PRESTRESSED WITH BONDED FRP TENDONS

A PRODUCT FROM KANTAFLEX (INDIA) PVT LIMITED

Dynamic Shear Rheometer: DSR

Application of the modified split-cantilever beam for mode-iii toughness measurement

with Fillers Department of Civil Engineering, National Taipei University of Technology, Taiwan, R.O.C

EVALUATING CREEP COMPLIANCE OF ASPHALTIC PAVING MIXTURES USING A HOLLOW-CYLINDER TENSILE TESTER

Textile Reinforced Concrete (TRC) for precast Stay-in-Place formwork elements

Experimental Study of Reinforced Concrete (RC) Beams Strengthened by Carbon Fiber Reinforced Polymer (CFRP): Effect of Beam Size and Length of CFRP.

Innovative SMA-MA mixture for bridge asphalt pavement

Flexural Behavior of RC T- Section Beams Strengthened with Different Configurations of CFRP Laminates

L Shaped End Anchors to Eliminate Premature Plate End Debonding in Strengthened RC Beams

Nonlinear Models of Reinforced and Post-tensioned Concrete Beams

Initial Tests of Kevlar Prestressed Timber Beams

The influence of the asphalt mixture components on asphalt mixture behavior

Residual Strengths of Reinforced Concrete Beams With Heavy Deterioration

Reinforced mastic asphalt Reinforcing of mastic asphalt with carbon fibres

Concrete-filled fiber reinforced polymer tube-footing interaction in bending

Slenderness ratio effect on the behavior of steel and carbon-frp reinforced concrete-filled FRP tubes

EXPERIMENTAL STUDY ON RC COLUMNS RETROFITTED BY FRP AND SUBJECTED TO SEISMIC LOADING

Effect of Bar-cutoff and Bent-point Locations on Debonding Loads in RC Beams Strengthened with CFRP Plates

INNOVATIVE MAINTENANCE MATERIALS, EQUIPMENT AND OPERATIONS FOAMED ASPHALT. Tomas Trevino, P.E. Maintenance Engineer Corpus Christi District

STRENGTHENING OF UNBONDED POST-TENSIONED CONCRETE SLABS USING EXTERNAL FRP COMPOSITES

Structural behavior of eccentrically loaded FRP confined square RC columns

BEST PRACTICES FOR IMPLEMENTATION OF TACK COAT: PART 1, LABORATORY STUDY

SEAUPG 2002 CONFERENCE

Table of content of printouts:

EVALUATION OF LAMINATED HOLLOW CIRCULAR ELASTOMERIC RUBBER BEARING

UHPC Connection of Precast Bridge Deck

Crack detection in composite bridges with relative displacement sensors

BEHAVIOR OF INFILL MASONRY WALLS STRENGTHENED WITH FRP MATERIALS

Performance of Recycled Rubber Modified Binders in Warm Mix Asphalt Mixtures

Cold-in-Place Recycling

Field Load Testing of the First Vehicular Timber Bridge in Korea

ASPHALT RUBBER INTERLAYER BENEFITS ON REFLECTIVE CRACK RETARDATION OF FLEXIBLE PAVEMENT OVERLAYS

Nonlinear Finite Element Modeling & Simulation

SEISMIC RETROFITTING OF REINFORCED CONCRETE COLUMNS USING CARBON FIBER REINFORCED POLYMER (CFRP)

Performance Graded (PG) Asphalts

THE PERFORMANCE OF CONCRETE GROUND FLOOR SLAB REINFORCEMENT TO CONTROL SHRINKAGE CRACKING. D H Chisholm 1

Design of Rigid Pavements

IMPROVING SHEAR CAPACITY OF RC BEAMS USING EPOXY BONDED CONTINOUS STEEL PLATES

Behaviour of Concrete Filled Rectangular Steel Tube Column

3. MECHANICAL PROPERTIES OF STRUCTURAL MATERIALS

GFRP retrofitted RC frames with columns subjected to high axial stresses

Numerical Modeling of Reinforced Concrete Beams Strengthened by NSM-CFRP Technique

A DESIGN-BASED APPROACH TO ESTIMATE THE MOMENT-CURVATURE RELATIONSHIP OF FIBER REINFORCED ELEMENTS FAILING IN BENDING. Report A0.T0.UM.

mortarless Design Manual Part 1 (AS 3600:2009) Section 1 Page 1 AS 3600:2009 PLAIN AND REINFORCED CONCRETE - CODE OF PRACTICE

SHEAR BEHAVIOR OF RC BEAMS USING U-SHAPED UFC PERMANENT FORMWORK WITH SHEAR KEYS OR BOLTS

PROJECT DETAILS - Effects of Implements of Husbandry (Farm Equipment) on Pavement Performance

Transcription:

Fourth International Conference on FRP Composites in Civil Engineering (CICE2008) 22-24July 2008, Zurich, Switzerland Evaluating and Modelling the Effect of Carbon Fiber Grid Reinforcement in a Model Asphalt Pavement M. N. Partl & K. Sokolov & H. Kim Swiss Federal Laboratories for Materials Testing and Research (Empa), Dübendorf, Switzerland ABSTRACT: Laboratory and modeling results on a special type of carbon fiber grid placed at different depth in model asphalt pavements are presented. The purpose was to obtain design information regarding the position of the grid to reach optimum effect. Two completely different types of asphalt pavements were investigated: asphalt concrete and mastic asphalt. Depending on the different application range of these materials, the test program was slightly different in each case. In case of asphalt concrete, special focus was devoted to the question of rutting performance with the Model Mobile Load Simulator MMLS where the asphalt layer was placed on a rubber pad foundation in order to increase bending effects. Test results are discussed and compared with dynamic FE modeling using ABAQUS. In addition, interlayer shear properties were investigated with the layer parallel direct shear test LPDS based on the Leutner device. The evaluation of the complex modulus in the coaxial shear test CAST developed by EMPA is also presented. In case of mastic asphalt, rutting and cracking resistance were considered varying the mesh width of the grid. Here, MMLS and LCPC rutting tests were performed. As for cracking resistance, the influence on bottom up cracking regarding bridge deck application at freezing temperature was evaluated with a special mechanical stretching bench that enabled to study a model system with a mastic asphalt placed on a bituminous waterproofing membrane. 1 INTRODUCTION Reinforcement of asphalt pavements with grids has attracted much attention and has triggered international initiatives such as the European Cost 348 REIPAS (Rathmayer 2006). Nowadays, a considerable variety of different products is available and still under development raising questions of appropriate testing and modeling. In this investigation emphasis was given to testing and evaluation of the following three cases: Carbon fiber grid reinforcement against traffic induced fatigue distress of hot mix asphalt (HMA): The effect of carbon fiber grid reinforcements, placed at different positions between two layers of HMA, was analysed. Furthermore, the influence of pretreating the surface of the bottom pavement layer by surface milling was investigated. The experimental results were qualitatively confirmed by finite element modelling, as shown in section 2 Carbon fiber grid reinforcement against low temperature cracking of mastic asphalt (MA):The mechanical behaviour of two layered MA specimens under horizontal repeated loading at low temperatures was investigated. The carbon fibre grid reinforcements were placed between the pavement layers. The most important findings are presented in section 3. Carbon fiber grid reinforcement against rutting of mastic asphalt (MA): The influence of the carbon fibre grid reinforcements on rutting behaviour of two-layered MAspecimens at different test temperatures was investigated. These results are summarised in section 4. - 1 -

2 REINFORCEMENT AGAINST TRAFFIC INDUCED FATIGUE DISTRESS OF HMA 2.1 Experiments Five two-layered specimens were produced using asphalt concrete AC 8 S for testing with the Model Mobile traffic Load Simulator MMLS. The AC 8 S layers of the specimens were compacted with a vibration roller compactor. Length, width and height of the specimens were 1800 x 870 x 60 mm. The first specimen (K1) was composed of two asphalt layers without grid reinforcement and served as reference. The other specimens were reinforced by carbon fibre grids either applied at the bottom side of the bottom asphalt layer (specimen K2) or in between the asphalt layers (specimens K3, K4, K5). The bottom asphalt layer of specimen K5 was produced at excess thickness of 5 mm (total thickness 25 mm). Before applying the reinforcement grid, these additional 5 mm were milled off with a hand miller, resulting in a final thickness of 20 mm. In order to simulate the compliance of the subbase, the specimens were supported by a cellular rubber pad. Details regarding the MMLS specimens and carbon fibre grids are given in Figure 1 and Table 1. The theoretical fiber cross-section of carbon fiber, according to 50 mm 2 /m, and the elasticity modulus of the carbon fibre grid are 160 GPa (carbon fibre) and 47 GPa (glass fibre). The coated matrix of fibre grids is SBS (Styrene-Butadiene-Styrene) polymer modified bitumen. Top asphalt layer Carbon Kohlefasern Fiber (Perpendicular (senkrecht zur to to Driving Fahrtrichtung) driving Direction) Direction) direction) 60 12 Support (cellular rubber pad) 1800mm Bottom asphalt layer t2 t1 Glasfasern Glass Fiber (in (In der Fahrtrichtung) the driving direction) Figure 1. Longitudinal cross section of the asphalt concrete specimens for MMLS testing and Carbon fibre grid (units in mm) Table 1. Asphalt concrete specimens, system characteristics Specimen- Code Specimen Size [mm] Surface Treatment Bottom Layer Thickness t1 Bottom Asphalt Layer [mm] Thickness t2 Top Asphalt Layer [mm] Grid Position K1 No 30 30 No Reinforcement K2 No 30 30 Bottom Side of Bottom Asphalt Layer 1800 x 870 K3 No 20 40 Between Asphalt Layers x 60 K4 No 30 30 Between Asphalt Layers K5 Milled 20 40 Between Asphalt Layers In order to measure the strains on the bottom of the specimens during MMLS testing, strain gauges were applied. The vertical surface displacements of the specimens (rut depths) were measured in a selected cross section of the specimens with a special profilometer. The traffic simulator MMLS was positioned on top of the specimen as shown in Figure 2. The combination of test parameters (tire width 80 mm, tire diameter 300 mm, tire load 2.1 kn) corresponds approximately to the vertical tire load of a regular truck. The test temperature was 25 C. Average permanent strains in the longitudinal strain gauge under the wheel path after ca. 0.5 Mio. cycles at 25 C showed that a reinforcement grid placed below or within the neutral plain of the specimen, leads to a reduction of the horizontal strains in the rutting zone. Comparing the average strains in specimen K2 (grid reinforcement on bottom side of bottom layer) with the values from specimens K3, K4 and K5 (grid reinforcement between asphalt layers) demonstrated that the carbon fibre grid reinforcement must always be placed between two pavement layers. It was also found that the application of the carbon fiber reinforcement between sub grade and asphalt base does not make sense. - 2 -

9km/h 2400mm 2.1kN 300mm 940mm 1200mm Figure 2. Model Mobile traffic Load Simulator MMLS, positioned on top of the specimen. Interlayer shear properties were determined with the layer parallel direct shear test LPDS based on the Leutner device according to Swiss standard SN 670461, except for the test temperature of 25 C, which was equal to the temperature of the MMLS tests. From the MMLS specimens K1, K3 and K4, three Leutner-specimens (double layered cylinders with a diameter of 150 mm) were cored and tested, each from the trafficked and nontrafficked zone (e.g. inside and outside the wheel track). From each zone of the MMLS specimen K5 (with milled interlayer interface) six Leutner-specimens were cored and tested. Prior to testing the specimens were conditioned at 25 C in a climatic chamber during 8 hours. The Leutner shear tests led to a dramatic decrease of the interlayer shear strength of the specimens from the wheel track zone from 20.3 kn (for K1) to 6.0 kn (for K4). This can be explained by successive loosening of the interface between the asphalt layers in presence of the reinforcement. 0.5 Mio. cycles, acting on the only 60 mm thick specimens, supported by the soft cellular rubber pad, produced vibrations with high horizontal stresses and strains that caused debonding in the boundary layer. The high values of the interlayer shear force of specimen K5 outside (18.3kN) and inside (17.7kN) the wheel track confirm that appropriate pre-treatment (e.g. milling) of the contact zone between the pavement layers improves the interlayer shear bond and therefore increases the efficiency of the carbon fibre grid reinforcement significantly. 2.2 Numerical Analysis In order to verify the experimental investigations, the specimens K1 to K4 were numerically modelled. For the asphalt concrete specimens, tested with the MMLS, a four layer finite element model was used. Calculation and visualisation was conducted with the software package ABAQUS. The traffic load was simulated as a moving vertical stress distribution under the wheel and adjusted to the wheel load of the MMLS traffic simulator. For this study elements of type C3D8R (8 point prismatic element with reduced integration), linear elastic material properties and the explicit dynamic solver were chosen. For the boundary conditions, the bottom of rubber pad layer was vertically fixed and the lateral sides of FE model have no boundary fixation. The carbon hanks of the reinforcement grid were implemented as rebar-elements in an asphalt layer of 4 mm thickness. Each finite element calculation was performed for one tire cycle taking into account the E moduli for the asphalt (1000MPa), for the supporting cellular rubber pad (0.19 MPa) and for the carbon fiber grid in the longitudinal (47 000MPa) and transversal direction (160 000MPa) assuming a grid spacing of 20mm and fiber cross section of 50mm 2 /m. The selected E-modulus of asphalt corresponds to the value determined in laboratory tests at a temperature of 25 C and a frequency of 0.5 Hz. Figure 3 shows the loaded elements of the model. Table 2 presents the longitudinal strain amplitudes on the bottom of the specimen under the wheel path, normalized to the K1 values. It can be noticed that the results of the experimental and numerical analysis are in qualitative agreement based on relative comparisons. The quantitative discrepancy indicates that the numerical model represents an idealised situation (perfect interlayer bond, linear elasticity). - 3 -

Figure 3. Finite element - modelling, loaded elements of MMLS-specimen K3. Table 2. Longitudinal strain amplitudes below wheel path on the bottom of the specimen (units in mm/mm). Specimen Code Experiment Finite Element Modelling K1 1 1 K2 0.7212 0.4545 K3 0.9038 0.4756 K4 0.9904 0.6324 3 REINFORCEMENT AGAINST LOW TEMPERATURE CRACKING OF MASTIC ASPHALT 3.1 Experiments The specimens had a length, width and height of 2600x500x70 mm, see Figure 4, and consisted of two mastic asphalt (MA) layers of mm thickness each, bridging a gap of 10 mm width. Between the bottom MA layer and the two concrete supports a SBS polymer bitumen flexible sheet for waterproofing was installed. reinforcement was placed in between the MA layers. The carbon fibres of the grid were oriented in longitudinal direction perpendicular to the gap. Table 3 provides an overview of the specimen characteristics. Mastic asphalt 150 70 Flexible bitumen sheet 10 Concrete support 2600 Gap cover plate (t = 3 mm) Specimen width: 500 mm. Figure 4. Longitudinal cross section of MA specimens for low temperature tests (units in mm) Table 3. Mastic asphalt specimens, system characteristics Specimen Thickness of MA Bottom Thickness of MA Upper Code Mix Grid Spacing [mm] Layer[mm] Layer [mm] K6 20 K7 MA11 40 K8 No Grid In order to investigate the behaviour of the specimens under repeated horizontal opening and closing of the gap at low temperature (-5 C), a special test equipment available at Empa, the so called Joint Movement Simulator JMS, was used (Figure 5). One side of the specimen was fixed on the concrete support, the other side was moved with a spindle motor in horizontal direction. The repeated loading was applied deformation controlled at constant testing temperature. The - 4 -

average speed of the gap opening was 5 mm/h. The gap opening was measured as distance between the concrete supports at both sides of the specimen with the LVDT deformation sensors W1. The horizontal deformation of the MA in the gap zone was measured with two LVDTs W2 that were mounted at half height of the bottom MA layer in front and at the back side of the specimen. For qualitative investigation of the longitudinal strain distribution, vertical marker lines were laterally painted on the specimen in a distance of 20 mm (Figure 5). Table 4 contains the test conditions and some test results. The basis length L2 of 150mm (K6), 250mm (K7, K8) was used for calculating the strains in the MA from W2 data. Base length L2 LVDT W2 MA-layers 500 100 Loading direction Fixed part LVDT W1 Moving part Figure 5. Schematic of the joint movement simulator JMS (units in mm) and detailed view Table 4. Mastic asphalt specimens, system characteristics and test results Specimen Code Maximal Gap Opening W1 [mm] Number of Load Cycles [kn] Maximal Strain W2/L2 in MA [%] Maximal nominal Stress in MA [MPa] E-Modulus E [MPa] 1 6 0.0883 1.295 1466 2 4 0.1713 2.121 1238 K6 3 4 0.2527 2.421 958 4 1 0.3413 2.538 743 5.984 (failure) 1 (failure) 0.547 3.267 684 1 6 0.075 1.157 1543 2 4 0.138 1.858 1342 K7 3 4 0.198 2.319 1168 4 2 0.268 2.870 1070 4.78 (failure) 1 (failure) 0.360 3.138 871 K8 3.58 (failure) 1 (failure) 0.244 2.849 1167 3.2 Analysis of Results From Table 4 follows that the application of the carbon fiber grid reinforcement leads to both a stiffening of the MA pavement (increase of the initial E-modulus) and an increase of its failure strain and stress. Table 5 presents a comparison of these parameters for all specimens. The values were taken from Table 4 (Italic terms) and are given as percentage of the value for the nonreinforced specimen K8. It follows that carbon fibre grid with narrow spacing leads to a significantly higher failure strain than the grid with a larger grid spacing (224.2% for K6 vs. 147.5% for K7). However the increase of failure stress remained small (114.7% for K6 vs. 110.1% for K7). No increase of initial stiffness was observed (125.6% for K6 vs. 132.25 for K7). Table 5. Comparison of test results Specimen Code Failure Strain [%] Failure Stress [%] Initial-E-Modulus [%] K6 224.2 114.7 125.6 K7 147.5 110.1 132.2 K8 (reference) 100 100 100-5 -

4 REINFORCEMENT AGAINST RUTTING OF MASTIC ASPHALT 4.1 Experiments The specimens had a length, width and height of 2000x1200x70 mm, see Figure 6, and consisted of two mastic asphalt layers MA11 of mm thickness each. In between the MA layers of some selected specimens a carbon fiber grid reinforcement was placed. The carbon fibers of the reinforcement grid were oriented in transversal direction perpendicular to the wheel tracking direction. Table 6 presents a summary of the specimen characteristics and the measured rut depths at the end of the MMLS tests. Mastic asphalt 70 Concrete plate 2000 Specimen width: 1200 mm. Figure 6. Longitudinal cross section of MA specimens for MMLS rut tests at 45 and 60 C (units in mm) Table 6. Mastic asphalt specimens, system characteristics and rut depths after MMLS testing Specimen Code Grid Spacing [mm] Number of Cycles Test Temperature [ C] Rut Depth [mm] K9 20 72000 45 4.60 K10 40 72000 45 4.62 K13 20 72000 45 4.78 K11 40 10000 60 11.62 K12 no grid 10000 60 11.34 K14 no grid 10000 60 8.13 From Table 6 follows that the carbon fiber grid reinforcement has no significant positive effect on the rutting behaviour of MA 11 at 45 C and 60 C. The grid structure is not able to prevent plastic deformations (flow) in the MA layer. A reduction of rutting must therefore be achieved by other means, e.g. by using harder binder. 5 CONCLUSIONS This study demonstrates the following positive properties of carbon fibre grid reinforced in a model hot mix asphalt and mastic asphalt as compared to non reinforced pavements: Increased resistance against low temperature cracking Increased stiffness of the pavement Increased failure strain and stress However, the grid was not found to improve resistance against plastic deformations in the MA layer during rutting tests with Model Mobile traffic Load Simulator MMLS. It was also found that careful pre-treatement is required in order to reduce the risk of interlayer debonding. 6 REFERENCES Rathmayer, Hans. 2006. Reinforcement of Pavements with Steel Meshes and Geosynthetics. European COST 348 REIPAS Swiss Standard SN 670461. 2000. Bituminöses Mischgut: Bestimmung des Schichtenverbundes nach Leutner - 6 -