WrapShield SA Brick Tie Penetration

Similar documents
RevealShield SA Penetrations

VAPROLIQUI-FLASH. Liquid Applied Waterproof Flashing Material INSTALLATION INSTRUCTIONS

INSTALLING WATER-RESISTIVE BARRIERS & FLASHING

Pella 250 Series. Wood Frame Construction with Vinyl Siding... V250-ID-888 Wood Frame Construction with Brick Veneer...

Henry Blueskin VP160 Air Barrier System Installation Manual

ELEVATION FOR DETAIL REFERENCE ONLY

Senergy Platinum CI Stucco Typical details for an impact resistant cement plaster stucco system featuring Neopor GPS Plus Rigid Insulation Board

SINGLE FAMILY USER S BULLETIN FOR INSTALLATION OF DUPONT WEATHERIZATION SYSTEMS PRODUCTS

WEB BASED APPLICATION SPECIFIC INSTALLATION INSTRUCTIONS

ELEVATION FOR DETAIL REFERENCE ONLY

BLUESKIN VP160 INSTALLATION GUIDELINES

MULTI-FAMILY USER S BULLETIN FOR INSTALLATION OF DUPONT WEATHERIZATION SYSTEMS PRODUCTS

NEXT GENERATION HIGH PERFORMANCE WALLS

DuPont Tyvek Air Barrier Installation Guidelines. Canadian Version. Version 2

AcroWall-ES System. Class PB Exterior Insulation and Finish System providing a primary moisture barrier. Typical Details

FMA_AAMA_WDMA Installation Committee Update FMA Conference May 8, Naples, FL. Jim Katsaros FMA_AAMA_WDMA Installation Committee

ELEVATION FOR DETAIL REFERENCE ONLY

SECTION FLUID-APPLIED VAPOR PERMEABLE MEMBRANE AIR BARRIER SYSTEM ASSEMBLY (August 2013)

ELEVATION FOR DETAIL REFERENCE ONLY

Tensile ASTM D1970 MD = 939 psi / CD = 1252 psi Self Sealability / water penetration resistance around nails. ASTM D1970 Section 7.

application instructions

How do you install yours?

DOWSIL Silicone Transition System: Application Guide Build a Better Barrier

Perimeter Relief and Control Joints in Fire-Rated Gypsum Board

SECTION MODIFIED BITUMINOUS MEMBRANE ROOFING Peel & Roof

ELEVATION FOR DETAIL REFERENCE ONLY

DuPont. Tyvek Sheathing Membrane Installation Guidelines. Version 2. Canadian Version

WARRANTY PROVIDER ACCEPTED A REFERENCE GUIDE OF TYPICAL RAINSCREEN WALL AND WINDOW DETAILS

Evaluating effectiveness of window/wall interface details to manage rainwater Selected Results from US Window Installation Practice

Avoiding Air Barrier Pitfalls When sub-trade activities are not in sync with air barrier requirements, installation can go poorly.

FACADES - ACM BASE AT OVERHANG (WITH BASE FLASHING) INDEX SHEET

The Disclaimer located on the reverse side of the title page of the OAA Rain Penetration Practice Guide applies to each section of the Guide.

SURESILL WATER MANAGEMENT GUIDE

DefendAir 200: Application Guide

AquaFlash System Installation Guide DS196

Detail Set: Thermax Wall System Masonry

BUILDING SUCCESSFULLY WITH DRYVIT RESIDENTIAL SYSTEMS.

Senturion TM III Wall System

Dow Corning DefendAir 200: Application Guide

FMA / AAMA / WDMA Installation Committee Update. Jim Katsaros / DuPont Building Innovations FMA Installation Committee April 24, 2012

NCMA TEK TEK 19-5A FLASHING DETAILS FOR CONCRETE MASONRY WALLS

INSTALLATION MANUAL. ZIP System R12 Sheathing. Contents. 07 ZIP System R12 Sheathing Window Installation 08 ZIP System R12 Sheathing Siding Guidelines

Roof Replacement. Notes: T-1 (Title Sheet) Roof Key Plan Russell House Student Union 1400 Greene Street Columbia, South Carolina 29208

SECTION ELASTOMERIC MEMBRANE ROOFING

General. Moisture. Secondary Water-Resistive Barrier. Storage. Gaps & Sealants. Stud Spacing. Flashing, Windows, Doors & Openings

Installation Guidelines for Adhered Concrete Masonry Veneer

BULLETIN FROM THE FIRST COAST CHAPTER ICC~BOAF

for New Construction Applications

Detail Drawings THE BEST PANEL COMPANY. from. 126 Old Highway 60 East Hardinsburg, Kentucky Office:

Light-Metal Roof Edge, Raised

Air and Vapor Barrier 3015

Managing Rainwater at the Window-Wall Interface

2006 Building Code Flashing Changes & Challenges. Builder Breakfast and Luncheon Series Presented by:

2001Co. Compression Board Air Seal Terminations Are a Patented Roof Application Technique

Fundamentals of Door Installation START

Rainscreen Gaps in Exterior Walls

A. This Section provides information regarding vapor permeable roof underlayment for the exterior roof.

LP SmartSide Perfection Shingle

Senershield -R / Senershield -VB

Incorporating Insulating Sheathing into the Design of the Thermal and Moisture Management System of the Building Enclosure

Parex USA Stucco Details CSI SECTION

INSTALLATION INSTRUCTIONS

Rain tightness of wind barrier and sealing of window joints Experimental laboratory testing

SECTION THERMOPLASTIC POLYOLEFIN (TPO) ROOFING PART 1 - GENERAL 1.1 RELATED DOCUMENTS

(Project Location) (your firm's name)

Tech Solutions WEATHERMATE Straight Flashing. Commercial Installation Guide

HIDDEN HOLES IN WOOD FRAMED BALCONY WATERPROOFING

SECTION VAPOR PERMEABLE FLUID-APPLIED AIR BARRIER MEMBRANE

Colphene BSW Training and Application Guide. Colphene BSW Waterproofing Membrane. 1. Prepare substrate

DuPont RainVent Batten Installation Guidelines

Proper Installation of Insulated Metal Wall Panels

Application Instructions for Dryvit Backstop NT For Use Beneath Claddings Other Than Dryvit EIFS

WEB BASED APPLICATION SPECIFIC INSTALLATION INSTRUCTIONS

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: COMPOSITE WALL PANELS REPORT HOLDER: ARCONIC ARCHITECTURAL PRODUCTS, LLC

SECTION 07530CP EPDM MEMBRANE ROOFING

OSB.COMFORT INSTALLATION GUIDE * 1 RECOMMENDED USE PANEL COMPOSITION

PLYWOOD FLOATING FLOOR

Johns Manville MinWool Water & Fire Block Mineral Wool Insulation

SECTION SHEET MEMBRANE WATERPROOFING AND CRACK ISOLATION

Installation Procedures for the Ultra Air Barrier Wall System

Magnum Board Section Digicon Information Inc. Page 1

WEB BASED CORE APPLICATION SPECIFIC INSTALLATION INFORMATION AND METHODS

NU-WALL EXTRUDED ALUMINIUM CLADDING. Installation Specifications Vertical orientation (over cavity)

Feature Zone IECC 2009 IECC

Finestone Stucco Ultra Wall System

ROOF ASSEMBLIES CHAPTER 9

WEB BASED APPLICATION SPECIFIC INSTALLATION INSTRUCTIONS

NOVABRIK MORTARLESS CONCRETE BRICK VENEER SPECIFICATION. MASTERFORMAT SECTION (Mortarless Concrete Brick Veneer)

The better way to build TM. Installation Manual FOUNDATION SIPs & FROST WALLS SIPs

FMA Installation Committee

KS SERIES - VERTICAL INSTALLATION

Residential Building Inspections

A. Meet at Project site <insert number> days before starting installation.

Table Air Barrier and Insulation Inspection Component Criteria

Metafor Panel System Installation Guide

MID-RISE DESIGN & CONSTRUCTION

RS32 Multi-Section Skylight System under/over seam clip double diverter

ROOF ASSEMBLIES CHAPTER 9

Insulated Panels North America. KarrierPanel Universal Barrier Wall Solution

Water Penetration Resistance - Design and Detailing

Transcription:

Brick Tie Penetration Outboard Vapor - Pemeable Insulation WrapShield SA Self-adhered WRB/AB field membrane Brick Tie must be Flush and compressed against Membrane with no prong penetrations Gasketed Fastener or Dow 758 Sealed 23.09.2012 A Vapor permeable, weather-resistive, air VaproLiqui-Flash vapor permeable, liquid WrapShield SA with VaproLiqui- Flash and VaproFlashing SA (Self- Adhered) creates a complete air barrier membrane over gypsum or plywood sheathing, concrete, and CMU blocks.

Low Roof to Wall Detail WrapShield SA Self-adhered WRB/AB field membrane shingled over flashing 3" Overlap Vertical Seams Outboard Vapor - permeable insulation Air Gap Behind Cladding WrapShield SA Laps over Flashing VaproFlashing SA Shingled under Flashing and over Roofing Membrane Flashing Roofing Membrane CMU, Concrete, or Sheathing in "as new" condition 23.09.2012 A Vapor permeable, weather-resistive, air VaproLiqui-Flash vapor permeable, liquid WrapShield SA with VaproLiqui- Flash and VaproFlashing SA (Self- Adhered) creates a complete air barrier membrane over gypsum or plywood sheathing, concrete, and CMU blocks.

Penetrations For Larger Penetrations, use VaproLiqui-Flash tooled at least 2" onto the face and 2" out along all sides of the penetration Apply sufficient Dow 758 Sealant to completely seal fastener penetrations Apply VaproLiqui-Flash to complex penetrations [i.e. structural elements] tooled evenly at least 2" onto the face and at least 2" out along all sides of the penetration 2" 2" 2" OK to apply VaproLiqui-Flash to damp substrate 2" Apply and lightly tool Dow 758 Sealant around smaller penetrations up to 1" in Diameter Gasketed Fasteners Require no additional Sealing 23.09.2012 A Vapor permeable, weather-resistive, air VaproLiqui-Flash vapor permeable, liquid WrapShield SA with VaproLiqui- Flash and VaproFlashing SA (Self- Adhered) creates a complete air barrier membrane over gypsum or plywood sheathing, concrete, and CMU blocks.

Parapet Detail [Inside Isometric] Parapet Cap VaproFlashing SA WRB/AB Self-adhered Flashing shingled over Field Membrane High-temp Roof Flashing Properly Shingled Dow 758 Sealant As needed Roofing Membrane Sheathing in "as new" condition 23.09.2012 A Vapor permeable, weather-resistive, air VaproLiqui-Flash vapor permeable, liquid WrapShield SA with VaproLiqui- Flash and VaproFlashing SA (Self- Adhered) creates a complete air barrier membrane over gypsum or plywood sheathing, concrete, and CMU blocks.

High-temp Roof Flashing Properly Shingled Parapet Cap WrapShield SA Parapet Detail [Outside Isometric] VaproFlashing SA WRB/AB Self-adhered Flashing shingled over Field Membrane Roofing Membrane Flashing per Cladding mfr. Dow 758 Sealant As needed WrapShield SA Self-Adhered WRB/AB Field Membrane Roll Installed vertically Sheathing in "as new" condition VaproBattens Black 1/2" 23.09.2012 A Vapor permeable, weather-resistive, air VaproLiqui-Flash vapor permeable, liquid WrapShield SA with VaproLiqui- Flash and VaproFlashing SA (Self- Adhered) creates a complete air barrier membrane over gypsum or plywood sheathing, concrete, and CMU blocks.

Change in Plane WrapShield SA WRB / AB Field Membrane Sheathing in "as new" condition WrapShield SA WRB / AB Field Membrane lap onto thru-wall flashing [by others] min. 3" VaproFlashing SA with VaproLiqui-Flash lap 3" min. onto horiz. surface; seal with Dow 758 Sealant and backer rod where prudent WrapShield SA WRB / AB Field Membrane VaproBatten Rain Screen Batten System

Change in Substrate in "as new" condition

Damage / Defects Dow 758 Sealant tooled @ top edge of reverse lap VaproFlashing SA or WrapShield SA 6" lap around perimeter of damage

Deflection Joint Backer rod [by others] size determined by building envelope consultant WrapShield SA or VaproFlashing SA 2 layers / min. 3" lap past joint WrapShield SA WRB / AB Field Membrane Substrate in "as new" condition mortar joints struck flush

Expansion or Contraction Joint Substrate in "as new" condition VaproFlashing SA 11.75" with "loop" adhere 3" strip to center of WrapShield SA to back side: adhesive to adhesive WrapShield SA Self-Adhered WRB/AB Field Membrane lap onto VaproFlashing SA min. 3" Plan View (NTS)

Self-adhered WRB/AB field membrane shingled over flashing + Nail-Flange @ head/jambs Sheathing in "as new" condition WrapShield SA Nail-Flange Window Detail Integrated Head flashing by others over VaproLiqui-Flash Nail Flange Window: flanges sealed to cured VaproLiqui-flash w/ Dow 758 Sealant - ⅜" min. bead @ jambs and head only interior backer rod and sealant by others U-Shims for drainage behind nail flange at sill per window mfr. instructions VaproLiqui-Flash @ inside Rough Opening + 2" on face monolithic and continuous VaproFlashing SA properly shingled; applied directly to sheathing + folder 2.75" inside of R.O. lapped over "Apron" and sealed WrapShield SA "Apron" 02.21.2013 A Vapor permeable, weatherresistive, air barrier self-adhered membrane with VaproLiqui-Flash vapor permeable, liquid applied flashing system. WrapShield SA with VaproLiqui- Flash and VaproFlashing SA (Self- Adhered) creates a complete air barrier membrane over gypsum or plywood sheathing, concrete, and CMU blocks. VaproShield LLC 915 26th Ave. N.W. Suite C5 Gig Harbor, WA 98335 Toll Free: 1.866.731.7663 www.vaproshield.com VaproShield 2/2013

Roof to Wall SlopeShield SA lap onto flashing and/or ice & water shield ice & water shield / flashing with butyl, acrylic, or hybrid adhesive Substrate in "as new" condition WrapShield SA WRB / AB Membrane lap min. 3" in shingle fashion at all seams

Substrate Joints Joints >⅜" require backing in "as new" condition

Wall to Foundation in "as new" condition VaproFlashing SA or WrapShield SA 3" lap adhere to foundation