Master Specification SECTION GREEN ROOF DRAINAGE LAYER. Date: 22MAY07

Similar documents
Master Specification SECTION 02621

E. Section Polymer Modified Cement Waterproofing. K. Section Sub drainage: Foundation perimeter drainage.

AVM Drain Board 2000/2020

A. Product Data: Submit manufacturer s product data, with complete general and specific installation instructions, recommendations, and limitations.

SECTION MODIFIED BITUMINOUS MEMBRANE ROOFING Peel & Roof

SECTION THERMOPLASTIC POLYOLEFIN (TPO) ROOFING PART 1 - GENERAL 1.1 RELATED DOCUMENTS

DELTA -GARDEN ROOF SYSTEM with DELTA -FLORAXX

ENKASONIC FLOOR UNDERLAYMENT 9110

Floor Insulation Underlayment Section Sound Control Matting

CITY OF FARMINGTON 800 Municipal Drive Farmington, NM (505) Fax (505)

1. Rubberized asphalt waterproofing membrane, reinforced. 2. Molded sheet drainage panels. 3. Insulation. 4. Plaza deck pavers.

MASTER SPECIFICATION Based on CSI MasterFormat 2004 SECTION VEGETATED ROOF STANDARD MULTILAYER

SLAB ON GRADE Insul-Joint or Expansion Joint Material as Required by A/E Specifications AquaCheck Liquid Coating 400 (Waterproofing Membrane) with Aqu

SECTION 07530CP EPDM MEMBRANE ROOFING

SECTION ELASTOMERIC MEMBRANE ROOFING

SECTION mil thickness COLD FLUID-APPLIED WATERPROOFING

A. This Section provides information regarding vapor permeable roof underlayment for the exterior roof.

SECTION ROOF PEDESTAL PAVER SYSTEM

Guideline Specification ACRYMAX ARS-1-C Reinforced Composite Elastomeric Membrane System for Concrete Roofs Fluid-Applied Roofing

1. Decks, balconies, and sun porches 2. Walkways, ramps, and stairways 3. Patios and courtyards

A. Submit product data sheets and literature verifying physical properties of materials.

SECTION MANUFACTURED ROOF EXPANSION JOINTS

Sarnavap 1000E is an unsupported vapour control layer based on PE-LD (Low Density Polyethylen).

ITEM 458 WATERPROOFING FOR STRUCTURES

Construction. S-Vap 5000E SA Self-adhesive Vapour Barrier. Product Description

PRODUCT SPECIFICATIONS

SECTION PRE-ENGINEERED BUILDING INSULATION

SECTION MODIFIED BITUMINOUS SHEET WATERPROOFING

ROOF BALLAST MATERIALS ARCHITECTURAL CONCRETE PAVING SLABS SRS LEVELING BLOCK SYSTEM INSTALLATION PART GENERAL 1.

PERM-FLEX (JC) ASSEMBLY DIRECT APPLICATION TO CEMENT BOARD SUBSTRATES MANUFACTURERS SPECIFICATION / SECTION 09960

SECTION SELF-ADHERING SHEET WATERPROOFING

Louis Armstrong New Orleans International Airport NOAB Project # North Terminal Development Program Phase 1

CCW 500R Green Roof Waterproofing System PART I - GENERAL

Colphene BSW Training and Application Guide. Colphene BSW Waterproofing Membrane. 1. Prepare substrate

DESIGN GUIDELINE FLUID-APPLIED WATERPROOFING

A. The work of this section includes, but is not limited to, the following:

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017

ML150 Guide Specification

Exterior Walls below and above ground OLDROYD THE ULTIMATE WATERPROOF MEMBRANE SYSTEM

PERM-FLEX ASSEMBLY DIRECT APPLICATION TO CEMENTITIOUS SUBSTRATES MANUFACTURERS SPECIFICATION / SECTION 09960

SL150 Guide Specification

E.PROTECT COMPOSITE DECK WATERPROOFING SPECIFICATION

Bid # CHILD CARE CENTER PLAYGROUND SURFACE and EQUIPMENT INSTALLATION 2016 SECTION "C" TECHNICAL SPECIFICATIONS OWNER

ACADEMIC SUCCESS CENTER THE COLLEGE AT BROCKPORT STATE UNIVERSITY OF NEW YORK PROJECT NO

SPECIFICATIONS FOR PRECAST MODULAR BLOCK RETAINING WALL SYSTEM (revised 5/8/7)

GEOSYTHETIC SLOPE SPEC-V0704rev.doc STANDARD SPECIAL PROVISION FOR GEOSYNTHETIC REINFORCED SLOPE CONSTRUCTION

PRODUCT DATA SHEET SikaProof Bentonite

BENTOMAT CL GEOSYNTHETIC CLAY LINER SPECIFICATION GUIDELINES

SPECIFICATION GUIDELINE

A. Source Limitations: Obtain each type of building insulation through one source.

ROOF PAVER SYSTEM National Distribution SPEC - SECTION 07760

D. Product Test Reports: Based on evaluation of comprehensive tests performed by a qualified testing agency, for waterproofing.

Part of the Sikaplan WT Membrane System

ALLNEX DAMP PROOF AND TANKING MEMBRANES. Product. Scope. Appraisal No. 805 [2013] Appraisal No. 805 (2013) Amended 26 January 2018.

SECTION COLD APPLIED RUBBER MODIFIED ASPHALT WATERPROOFING

SECTION SELF-ADHERING SHEET WATERPROOFING (650 MEMBRANE SYSTEM)

EXCEL Medical Waste - Equipment Installation Section SECTION GYPSUM BOARD

A. This Section includes subdrainage systems for foundations and underslab areas. A. Product Data: For each type of drainage panel indicated.

TOPCOAT Restoration Specifications Structural Concrete

Elastomeric Protected Membrane Roofing Fluid-Applied Protected Membrane Roofing. Restoration Coating System (RCS) over Cap Sheet

SECTION ATHLETIC AND RECREATIONAL SURFACING. A. ASTM C 67 - Standard Test Methods for Sampling and Testing Brick and Structural Clay Tile.

A. National Roofing Contractors Association (NRCA) Roofing and Waterproofing Manual

1. Clean the existing totally adhered or mechanically attached roof membrane: TPO, EPDM, Hyplon,

Recommended Design Considerations. and. Guide Specifications For. Commercial Building Insulation

PRESTON HEALTH SERVICES ARCHITECT'S NO. 2700

SECTION CO-POLYMER ELASTOMERIC COOL-ROOF COATING

SECTION SPECIFICATION FOR STONEBRIDGE RETAINING WALL SYSTEM

UltraPly TPO SA. Product Information. Description: Membrane Preparation: Method of Application: Item Description

INSTALLING WATER-RESISTIVE BARRIERS & FLASHING

SPECIFICATION GUIDELINE

by Jason P. Wilen, AIA, CDT, RRO testing the integrity of a roof or waterproofing membrane. But since

@Copyright 2016 SKAPS Industries.

PRODUCT GUIDE SPECIFICATION

Roofing. Carrier Membrane SA. Self-adhesive Carrier Membrane. Product Description. Tests. Product Data. Form. Storage

Sept 30, 2004 Page 1

IPE WOOD DECK TILES National Distribution SPEC - SECTION 07760

FL200 13/4 x41/2 GUIDE SPECIFICATION. Non-Thermal Storefront

TRIDENT SEC 04 SECTION SAFETY AND SECURITY FILMS

SCOPE OF WORK PROJECT IDENTIFICATION

SECTION COMPOSITE METAL WALL PANEL SYSTEM (Accu-Trac Low Profile DS)

TILE TILE

STANDARDIZATION IN GEOTECH SECTOR V.K.PATIL

E.PROTECT+ COMPOSITE DECK WATERPROOFING SPECIFICATION

SECTION THERMOPLASTIC POLYOLEFIN (TPO) MEMBRANE ROOFING (Over Metal) A. Thermoplastic Polyolefin Membrane Roofing over metal decking.

SECTION EXTERIOR INSULATION AND FINISH SYSTEMS

LIQUID RUBBER INDUSTRIES ENGINEERING SPECIFICATIONS FOR ENGINEERS AND ARCHITECTS. Diagram 1: Standard Membrane Continuation 150 mm Overlap

Lamit Industries, Inc. 710 Marion Road Columbus, Ohio P-(614) F-(614)

SPECIFICATION FOR PREFABRICATED VERTICAL DRAIN

SECTION ROOF SPECIALTIES

MULE-HIDE PRODUCTS CO., INC. MULE-HIDE SELF-ADHERING TPO ROOFING SYSTEM

SECTION PERMEABLE INTERLOCKING CONCRETE UNIT PAVEMENT

SECTION FLUID-APPLIED VAPOR PERMEABLE MEMBRANE AIR BARRIER SYSTEM ASSEMBLY (August 2013)

Product Technical Bulletin APS-5T

Application of Geotextiles in Pavement Drainage Systems

(Project Location) (your firm's name)

***********************************************************************************

CS-100 Guide Specifications

FOAMULAR Insulation, PRMA, Horizontal Waterproofing

SECTION TPO WATERPROOFING MEMBRANE FOR FLAT ROOFS INSTALATION

DSC BUILDING 1200 ALTERATIONS OCTOBER 2011 SECTION DUCT INSULATION

Transcription:

Master Specification 33 46 23.19.1-1 SECTION 33 46 23.19.1 GREEN ROOF DRAINAGE LAYER Date: 22MAY07 PART 1 GENERAL 1.01 SUMMARY A. This specification describes the J-DRain GRS, Green Roof System and/or J-DRain 400 RB, one component of a Vegetated Roofing System. It is int ended to be used as a guide to the architect designing individual components of a complete Green Roof System. The remainder of the components required for this complete installation can be found in the Divisions listed below. 1.02 RELATED SECTIONS A. Division 31 Earthwork B. Division 32 Green Roof Planting C. Division 32 Pavers D. Division 3 Cast in Place Concrete E. Division 6 Miscellaneous Carpentry F. Division 7 Protected Membrane Roofing G. Division 7 Roof Drains H. Division 7 Vegetated Roofing I. Division 7 Thermal Insulation J. Division 7 Sheet Metal Flashing K. Division 7 Caulking and Sealants L. Division 22 Plumbing Specialties 1.03 REFERENCES and INDUSTRY STANDARDS A. American Society for Testing and Materials (ASTM) B. Underwriters Laboratories (UL) Class A 1.04 DEFINITIONS A. Roofing Terminology: Refer to the ASTM D 1079 and glossary of NRCA s The NRCA Roofing and Waterproofing Manual for definition of terms related to roofing work in this Section. B. Green Roof: Area of planting/landscaping, built up on a waterproofed substrate at any level that is separated from the natural ground by a man-made structure. C. Geotextile: Any permeable textile used with foundation, soil, rock, earth, or any other geotechnical material, as an integral part of man-made product, structure, or system.

Master Specification 33 46 23.19.1-2 D. Normal direction: Direction perpendicular to the plane of a geotextile. E. Permittivity: Volumetric flow rate of water per unit cross sectional area per unit head under laminar flow conditions, in the normal direction through a geotextile. F. Permeability: Rate of flow of a liquid under a differential pressure through a material. G. Transmissivity: Flow or amount of liquid water per foot of material width passing through composite system at certain maximum soil pressure against geotextile at defined hydraulic gradient. 1.05 SYSTEM DESCRIPTION A. Performance Requirements: Provide prefabricated drainage composites which have been manufactured and installed to maintain positive drainage without defects, damage or failure. 1.06 SUBMITTALS A. Product Data: Manufacturer s product data; indicate products supplied. Provide complete installation instructions proposed for use. B. Samples: 6 x 6 J-DRain GRS or J-DRain 400 RB, Green Roof Drainage sample. 1.07 QUALITY ASSURANCE A. Preinstallation Conferences: Coordinate with conference scheduled for roofing materials. Follow requirements indicated in waterproofing materials section. 1.08 DELIVERY, STORAGE, AND HANDLING A. Packing and shipping: Provide materials in original unopened containers with manufacturer s labels intact and legible. B. Acceptance at site: 1. Unload materials: check for damage. 2. Damaged materials determined by visual inspection will not be accepted. 3. Remove rejected materials from site immediately. C. Storage and protection: 1. Store materials in dry area in manufacturer s protective packaging in original containers with labels and installation instructions intact. 2. Store materials under cover, off ground; protect from sunlight. 3. Do not expose to aromatic hydrocarbons.

Master Specification 33 46 23.19.1-3 PART 2 PRODUCTS 2.01 MANUFACTURERS A. Basis of Design: J-DRain GRS, as manufactured by: 292 S. Main Street Suite 200 Alpharetta, GA 30004 Telephone: 800.843.7569 or 770.442.1461. Fax: 770.664.7951. Website: www.j-drain.com B. J-DRain GRS (Prefabricated Drainage Course): 1. A composite drainage system consisting of 100% post industrial polystyrene regrind dimple core and two layers of geosynthetic fabric attached top and bottom. It should meet the following properties: PROPERTY: TEST METHOD: VALUE DRAINAGE CORE: Compressive Strength (psf) ASTM D-1621 9500 Thickness (in.) ASTM D-1777 1.0 Flow @ 3600 psf & hydraulic ASTM D-4716 30 gradient of.1 for 300 hrs. (gal/min/ft. width) ROOT RESISTANT FABRIC: (*See Fabric Notes Below*) Basis Weight (oz.) 3.3 Grab Tensile (lbs/inch) ASTM D-4632 MD 54.2 CD 47 Grab Elongation (%) ASTM D-4632 MD 54 CD 78 Trapezoidal Tear (lbs.) ASTM D-4533 MD 26.2 CD 19.9 GEOTEXTILE: Mass/unit area (oz./sy) ASTM D-5261 4.0 Grab tensile strength (lbs.) ASTM D-4632 100 Puncture (lbs.) ASTM D-4833 65 WATER RETENTION: Capacity (gallons/sf) ASTM E-2398-05.10 C. DIMPLE CORE DRAINAGE SYSTEM material, characteristics: 1. Type: ; J-DRain 400 RB 2. CORE: a. Material: High impact polypropylene. b. Type: Formed dimpled core. c. Compressive strength: 400 RB: 15,000 PSF (719 kn/m 2 ).

Master Specification 33 46 23.19.1-4 3. GEOTEXTILE: J-DRain 400 RB: (*See Fabric Notes Below*) ROOT RESISTANT FABRIC: Basis Weight (oz.) 3.3 Grab Tensile (lbs/inch) ASTM D-4632 MD 54.2 CD 47 Grab Elongation (%) ASTM D-4632 MD 54 CD 78 Trapezoidal Tear (lbs.) ASTM D-4533 MD 26.2 CD 19.9 4. Adhesive bonding core material to geotextile: Pressure sensitive applied to core, manufacturer's standard. *FABRIC NOTES: Depending on plant choices and root behavior, this root resistant fabric will prohibit most, but not all, root growth from typical greenroof plants. This root resistant fabric is not to act as a substitute for the root barrier that is required at the waterproofing membrane layer. Please consult your waterproofing company for this criterion. Direct UV/sunlight can damage J-DRain products and can cause deterioration. To alleviate UV/sunlight damage, the engineered soil should be installed to cover J -DRain products within 10 14 days. D. DRAIN ACCESS BOX 1. Type: JDR Enteprises, Inc., powder coated aluminum casting with removable ventilated top and flange base. Access opening: 12 by 12 ; Flange: 18 by 18 ; Height: 6. 1. Purpose: Provides easy access and cover for inspection of floor drains in Green Roof applications. E. ADDITIONAL ROOT RESISTANT FABRIC (See properties listed under GRS). F. J-TAPE: Adhesive tape, available from JDR Enterprises. G. ADHESIVES, MASTIC AND TAPE: Liquid mastic and adhesives, compatible with the waterproofing system.

Master Specification 33 46 23.19.1-5 2.02 RELATED MATERIALS (Furnished by others, to adhere to architects recommendation and ASTM standards). A. Roof structure designed to support the weight of the complete Green Roof System. B. Roofing Membrane and all associated components for a complete water tight installation. C. Growth Media (Sand or other inorganic material). D. Plantings and Vegetation PART 3 EXECUTION 3.01 EXAMINATION A. Verification of conditions: 1. Examine conditions and substrates where products specified in this section are installed; submit written notification of unacceptable conditions or substrates. 2. Submit copy of installer's report to Architect within 72 hours of report receipt. 3. Proceeding with construction activities of this section: a. Indicates acceptance of conditions or substrates. b. Additional work in this section due to pre-existing conditions not noted will not be paid as extra. 3.02 PREPARATION OF SURFACE A. Contractor shall examine the deck area to be covered with subsequent topping materials in order to insure that all deck areas have received the roofing membrane, membrane is free of damage, it is properly protected, and all flashing (as required) has been properly installed. 3.03 GRS AND DIMPLE CORE DRAINAGE MAT INSTALLATION A. Starting at one end of roof, unroll J-DRain drainage composite out with the dimples facing down, retention cups up to hold water. B. Adhesive or double sided tape can be used if needed to hold material down until installation of Growth Media. Spot glue a 2 x 2 square spaced every 4 to 6 feet. C. It is essential to mark the position of ro of outlets before installing J-DRain, so they can be located easily and cut for easy access. D. Continue to roll to the end, cut to terminate. Follow to step E if additional J-DRain is needed. E. Additional roll may begin at this point and continue the length of the roof. Fold the fabric back over the joint and tape fabric with J-Tape and/or adhesives as required.

Master Specification 33 46 23.19.1-6 F. Install 2 nd run of drain mat identical to the 1 st run, placing drain core parallel to the 1 st run. Drain core should butt up to each other, side by side; they do not have to interlock. Peel back enough salvage edge of top filter fabric, tucking one edge under the other and overlapping the seams. G. Cover all exposed edges with extra filter fabric to ensure filter continuity. Use J-Tape to tape the seams. H. To prevent Growth Media from getting under this seam during installation, tape edges every 3 to 4 feet with J-Tape as optional protection if required. I. Additional GRS and/or root resistant fabric may be extended up the side of a parapet wall and terminated flush with Growth Media. J. Growth Media must be installed within 14 days in order to insure protection of the J-DRain. 3.04 ACCESS BOX INSTALLATION A. As drainage mat is being installed and roof drains have been located, cut a 12 x 12 opening in the drainage mat for the Access Box. Place Access Box directly over the roof drain. Backfill Growth Media up the sides of the Access Box. END OF SECTION 33 46 23.19.1 Specifications prepared for: 292 South Main Street Suite 200 Alpharetta GA 30004 Internet address: www.j-drain.com Voice: 800.843.7569 or 770.442.1461 Fax: 770.664.7951