GENERAL & AXIAL LOADBEARING

Similar documents
AND ACCESSORIES FOR DRYWALL CONSTRUCTION

STEEL STUD, TRIMS AND ACCESSORIES FOR DRYWALL CONSTRUCTION MONTREAL TORONTO CALGARY EDMONTON VANCOUVER THE STRENGTH WITHIN

vinyl Drywall trims montreal toronto CalGary EDmOntOn vancouver BA Metal Bead Brochure Aug 12.indd :31 AM

On Cold-Formed Steel Construction. Light Gauge Steel Engineers Association Washington, D.C Toll Free (866)

BEARING METAL STUD FRAMING

Commercial Structures

fifteen design for lateral loads Lateral Load Resistance Load Direction Lateral Load Resistance

EMERGENCY MANAGEMENT PREPAREDNESS AND ASSISTANCE TRUST FUND ARC 4496 Evaluation Questionnaire

Prefabricated Light Weight Steel Structures. Systems Guide WALLS, FLOORS, TRUSSES

Anchor bolts ASTM F1554, Gr. 36 Wide flange beams ASTM A992, Fy = 50 ksi Misc. structural steel ASTM A36, Fy = 36 ksi

The Homeowner s Building Application Checklist for Constructing a Residential Addition

LATERAL DRIFT DESIGN IN COLD FORMED STEEL WALL SYSTEMS

Colorado Chapter of the International Conference of Building Officials. Building Guide. The Colorado Chapter of the International

Contents. 1.1 Introduction 1

Details for Exterior Brick Masonry Veneer Supported by Metal Plate Connected Wood Trusses

INTRODUCTION TO CURTAIN WALL DESIGN USING COLD-FORMED STEEL

Gold Bond BRAND Gypsum Sheathing

COFS Mission. AISI Standards Hierarchy. North American Standards for Cold-Formed Steel Framing. Member versus System Design. Specification 10/21/2016

Technical Notes 43G - Brick Passive Solar Heating Systems - Part 7 - Details and Construction [Mar./Apr. 1981] (Reissued Sept.

Structural System. Design Criteria Fire Resistance Concrete designed for 2 HR rating (worst case) Geotechnical Report Allowable Bearing Capacity

Retain "Preinstallation Conference" Paragraph below if Work of this Section is extensive or complex enough to justify a conference.

MID-RISE DESIGN & CONSTRUCTION

ISO Types 1-6: Construction Code Descriptions

Chapter 2 EARTHQUAKE-RESISTANCE REQUIREMENTS

research report Fire Resistance Ratings of Load Bearing Steel Stud Walls With Gypsum Wallboard Protection RESEARCH REPORT RP REVISION 2007

ILLUSTRATED GUIDE. For Seismic Design of Houses. Lateral Bracing Requirements Part 9 BC Building Code 2012

Plan Check No. Checked by: An Appointment Is Required for Verification

Project Findings: Appendix 2

Nabil A. Rahman, Ph.D., P.E.

January 14, 2006 Structural Thesis Proposal: Structural and Breadth Redesign Options

CITY OF CEDAR FALLS DEPARTMENT OF DEVELOPMENTAL SERVICES INSPECTION SERVICES DIVISION PHONE Residential Accessory Structures

Types Of Roofs - Vault

2003 International Residential Building Code

TYPICAL BEARING WALL FRAMING

WASHINGTON STATE ENERGY CODE, APPENDIX CHAPTERS

City of Republic Community Development Girder and Header Spans for Exterior Walls

STRUCTURAL ISSUES IN RESIDENTIAL CONSTRUCTION. Presented by: Susan L. Lasecki P.E., S.E.

Introducing TJ Insulated Structural Framing Components

R CODE CHANGE PROPOSAL FORM (See instructions on page 2)

DETAIL DRAWINGS. RASTRA is a stay-in-place insulated concrete. form that is structurally strong, energy-efficient,

PRELIMINARY STRUCTURAL INVESTIGATION REPORT

Table of Contents.2. Introduction...3 Gravity Loading and Deflections..4. Existing Structural System..8

Hilton Baltimore Convention Center Hotel Western Podium

Building Systems and Design Elements included in SliDeRulE

Administrative Changes

Supplemental Plan Check List for Unreinforced Masonry (URM) Retrofit

Wall bracing panel requirements

AISC Steel & Timber Research for High-Rise Residential Buildings

Reconsidering the Approach towards Determining Overall Building Enclosure Thermal Performance for Code Compliance

Structural Technical Report #2 By Robert Whitaker

Residential Inspector s Guide: Building and Energy based on the 2009 International Residential Code Chapters 1-11

Residential Inspector s Guide: Building and Energy based on the 2009 International Residential Code Chapters 1-11

POST AND FRAME STRUCTURES (Pole Barns)

HOTEL NORTHEAST U.S. JORDAN RUTHERFORD STRUCTURAL OPTION FACULTY ADVISOR DR. THOMAS BOOTHBY AE SENIOR THESIS APRIL 8, 2013

Pro-Con Structural Study of Alternate Floor Systems

Assemblies Evaluated For 1. Non Axial Load Bearing Wall 2. Transverse Load Capacity 3. Fire Resistance 4. Abuse Resistance

Eric Alwine Structural Option George Read Hall The University of Delaware Dr. Boothby Technical Assignment #2 October 31, 2005 EXECUTIVE SUMMARY:

FDA CDRH Laboratory Silver Spring, Maryland. Executive Summary: Timothy Mueller Structural Option Walter Schneider

Building Guide. Colorado Chapter of the International Code Council

EDGEWATER, FLORIDA JUNE 14, 2010

SECTION (05400) - COLD-FORMED METAL FRAMING

2012 IRC Wood Wall Bracing

One and Two Family Additions

Brent Ellmann Structural Option 200 Minuteman Park, Andover, MA Structural Consultant: Dr. Hanagan

Structural Technical Report 1 Structural Concepts / Existing Conditions

BROCHURE # 108 CONSTRUCTION PLAN COMPONENTS

R Code and Commentary for 2012 NC Residential Code final 03/06/13

Precast Wall Panel Design. By Edward Losch, PE, SE

Council on Tall Buildings

SECTION PLATE CONNECTED WOOD TRUSSES

MITRE 3 Building McLean VA

NCMA TEK TEK 19-5A FLASHING DETAILS FOR CONCRETE MASONRY WALLS

PLYWOOD FLOATING FLOOR

DICTATOR Lift Shaft System

WOOD USE IN NONCOMBUSTIBLE BUILDINGS

RESEARCH HIGHLIGHT. Design and Construction of the Northern Sustainable House Arviat, Nunavut

Modular Wood Framing Goes Vertical

POST AND FRAME STRUCTURES (Pole Barns)

COLLEGE CLASSROOM & DORMITORY SPECIFICATION SECTION 08100

WALL CEILING FACADE ACCESSORIES ACCESS PANELS CONTACT CLICK TO START

90% Design Submittal Structural Calculations Parking Garage CDRL

HOW CONFINED MASONRY BUILDINGS FAIL IN EARTHQUAKES

SECTION NON-STRUCTURAL METAL FRAMING

Specifying Pre-Engineered CFS Floor and Roof Trusses 551f-98

111 MORGAN ST. Ryan Friis

The Structural Design of Laramie County Community College Student Services Center

Quality Inspection 8618 London Heights San Antonio, TX Phone: (210)

INSTALLING WATER-RESISTIVE BARRIERS & FLASHING

Open-Web Trusses. Including Red-L, Red-W, Red-S, Red-M and Red-H Trusses. Design Flexibility. Outstanding Strength-to-Weight Performance

CHAPTER 5 FLOORS SECTION R501

PRESENTATION CENTER SURREY, BC CANADA

Open-Web Trusses. Including Red-L, Red-W, Red-S, Red-M and Red-H Trusses. Design Flexibility. Outstanding Strength-to-Weight Performance

Composite / Veneer Units. Precision...1. Split Face... 2

2012 Wood Frame Construction Manual: Wind Load Distribution on Buildings Load Paths

ACCESSORY STRUCTURE Building permit information For 1 & 2-family dwellings

Hilton Baltimore Convention Center Hotel Western Podium

TECHNICAL NOTE. Design of Diagonal Strap Bracing Lateral Force Resisting Systems for the 2006 IBC. On Cold-Formed Steel Construction INTRODUCTION

Structural Redesign Gravity System

Two Stage Analysis Procedure: Wood on Podium Design

A Simple Solution for Meeting

Transcription:

LIGHTWEIGHT STEEL FRAMING DETAILS GENERAL & AXIAL LOADBEARING THE STRENGTH WITHIN MONTREAL TORONTO CALGARY EDMONTON VANCOUVER

WALL ELEVATIONS Bailey Wind Bearing Walls (BWB) Lightweight Steel Framing (LSF) provides economical structural support for finishes under lateral wind loads on buildings where other structural components carry axial loads. BWB walls can be designed for a variety of deflection limits for finishes such as EIFS, Stucco, Metal Panel and Brick Veneer. Wind-Bearing LSF may be used in buildings of any height. Bailey Axial Loadbearing Walls (BAB) Lightweight Steel Framing (LSF) supports the combined axial and wind loads on interior and exterior walls. Buildings up to six stories in height can be framed using LSF. LSF works with a variety of floors including LSF Joists, ComSlab composite flooring systems, OWSJ s and hollow precast concrete. EXTERIOR INFILL WALLS / CONTINUOUS EXTERIOR CURTAIN WALLS AXIAL LOAD BEARING WALLS 2 LIGHTWEIGHT STEEL FRAMING DETAILS GENERAL & AXIAL LOADBEARING

Bailey Joists for Floors & Roofs Lightweight Steel Framing (LSF) Joists offer a wide range of span and load capabilities for commercial and residential floor systems and mezzanines. LSF ceiling Joist members can also be utilized for pitched, mansard and flat roofs. The use of Bailey LSF Joist members will provide support for interior drywall ceilings where long clear spans are required. Bailey Non-Loadbearing Walls (BNLB) Lightweight Steel Framing (LSF) provides an effective solution for interior non-load bearing walls and partitions. When combined with top track deflection members, bulkheads will resist buckling caused by deflection of floor and roof assemblies. Non-load bearing LSF provides a stable framework for drywall or other finished wall surface applications. Bailey Spandrel Walls Lightweight Steel Framing (LSF) accommodates a variety of spans for continuous strip window applications. LSF provides a stable, square platform in which glazing units and frames can be effectively installed. SPANDREL WALLS FOR CONTINUOUS STRIP WINDOWS JOISTS FOR FLOORS & ROOFS TALL INTERIOR PARTITIONS The material presented in this document has been prepared for the general information of the reader. While the material is believed to be technically correct and in accordance with recognized good practice, it should not be used without first securing competent advice with respect to its suitability for any specific application. Bailey Metal Products Limited does not warrant or assume liability for the suitability of the material for any general or particular use. WWW.BMP-GROUP.COM 3

WALL ELEVATIONS AXIAL LOADBEARING WALL In axial loadbearing construction, some form of bracing is required to resist wind, seismic and sway effects produced by vertical loads acting on the structure (the P-delta effect). Diagonal tension straps are normally the most economical means of providing this bracing. Diagonal straps are typically installed in pairs to form the X pattern over the face of the studs. Strap end connections must be engineered to transfer the full design load and account for horizontal and vertical strap reactions. 4 LIGHTWEIGHT STEEL FRAMING DETAILS GENERAL & AXIAL LOADBEARING

GENERAL DETAILS BAILEY STUD TO BAILEY TRACK BAILEY STUD TO BAILEY PATENTED PUNCHED TRACK 1 2 3 BAILEY STUD REINFORCED WITH BAILEY TRACK BAILEY STUD WITH WEB STIFFENER REINFORCING JAMB STUD AT DOOR OPENING 4 5 6 BAILEY STUD TO BAILEY TRACK AT CORNERS THROUGH-THE-STUD 7 FLAT STRAP BRIDGING BRIDGING 8 9 NOTCHED CHANNEL BRIDGING EXTERIOR RIGID 10 EXTERIOR SHEATHING 11 INSULATION 12 EXTERIOR SHEATHING AND RIGID INSULATION WWW.BMP-GROUP.COM 5

AXIAL LOADBEARING WALLS 35 DIAGONAL TENSION STRAPS ONE SIDE 36 DIAGONAL TENSION STRAPS BOTH SIDES 37 TENSION STRAP CONNECTION 38 TENSION STRAP CONNECTION WITH GUSSET PLATES 6 LIGHTWEIGHT STEEL FRAMING DETAILS GENERAL & AXIAL LOADBEARING

AXIAL LOADBEARING WALLS 39 WALL OPENING WITH UPPER LINTEL 40 WALL OPENING WITH LOWER LINTEL 41 OPEN WEB STEEL JOISTS IN LINE WITH AXIAL LOADBEARING STEEL STUDS 20 OPEN WEB STEEL JOISTS OFFSET TO AXIAL LOADBEARING STEEL STUDS WWW.BMP-GROUP.COM 7

LIGHTWEIGHT STEEL FRAMING DETAILS GENERAL & AXIAL LOADBEARING sales@bmp-group.com www.bmp-group.com GXL07IN16-500 MONTREAL TORONTO CALGARY EDMONTON VANCOUVER 525 Avenue Edward VII Dorval, QC H9P 1E7 Tel. (514) 735-3455 800-263-3455 Fax. (514) 735-5052 1 Caldari Road Concord, ON L4K 3Z9 Tel. (905) 738-9267 800-668-2154 Fax. (905) 738-5712 3924 27th Street NE Calgary, AB T1Y 5K7 Tel. (403) 248-3536 800-665-2013 Fax. (403) 248-0288 5710 Roper Road NW Edmonton, AB T6B 3G7 Tel. (780) 462-5757 800-563-1751 Fax. (780) 450-3378 7715 Anvil Way Surrey, BC V3W 6A2 Tel. (604) 590-5100 800-818-2666 Fax. (604) 590-5105