GENERAL & WIND BEARING

Similar documents
AND ACCESSORIES FOR DRYWALL CONSTRUCTION

STEEL STUD, TRIMS AND ACCESSORIES FOR DRYWALL CONSTRUCTION MONTREAL TORONTO CALGARY EDMONTON VANCOUVER THE STRENGTH WITHIN

vinyl Drywall trims montreal toronto CalGary EDmOntOn vancouver BA Metal Bead Brochure Aug 12.indd :31 AM

On Cold-Formed Steel Construction. Light Gauge Steel Engineers Association Washington, D.C Toll Free (866)

BEARING METAL STUD FRAMING

EMERGENCY MANAGEMENT PREPAREDNESS AND ASSISTANCE TRUST FUND ARC 4496 Evaluation Questionnaire

MID-RISE DESIGN & CONSTRUCTION

Commercial Structures

The Homeowner s Building Application Checklist for Constructing a Residential Addition

ISO Types 1-6: Construction Code Descriptions

Prefabricated Light Weight Steel Structures. Systems Guide WALLS, FLOORS, TRUSSES

Colorado Chapter of the International Conference of Building Officials. Building Guide. The Colorado Chapter of the International

WALL CEILING FACADE ACCESSORIES ACCESS PANELS CONTACT CLICK TO START

INTRODUCTION TO CURTAIN WALL DESIGN USING COLD-FORMED STEEL

Anchor bolts ASTM F1554, Gr. 36 Wide flange beams ASTM A992, Fy = 50 ksi Misc. structural steel ASTM A36, Fy = 36 ksi

Technical Notes 43G - Brick Passive Solar Heating Systems - Part 7 - Details and Construction [Mar./Apr. 1981] (Reissued Sept.

City of Republic Community Development Girder and Header Spans for Exterior Walls

COFS Mission. AISI Standards Hierarchy. North American Standards for Cold-Formed Steel Framing. Member versus System Design. Specification 10/21/2016

LATERAL DRIFT DESIGN IN COLD FORMED STEEL WALL SYSTEMS

WASHINGTON STATE ENERGY CODE, APPENDIX CHAPTERS

SECTION NON-STRUCTURAL METAL FRAMING

INSTALLING WATER-RESISTIVE BARRIERS & FLASHING

PRELIMINARY STRUCTURAL INVESTIGATION REPORT

Assemblies Evaluated For 1. Non Axial Load Bearing Wall 2. Transverse Load Capacity 3. Fire Resistance 4. Abuse Resistance

fifteen design for lateral loads Lateral Load Resistance Load Direction Lateral Load Resistance

EDGEWATER, FLORIDA JUNE 14, 2010

Reconsidering the Approach towards Determining Overall Building Enclosure Thermal Performance for Code Compliance

Building Systems and Design Elements included in SliDeRulE

Senturion TM III Wall System

Administrative Changes

WOOD USE IN NONCOMBUSTIBLE BUILDINGS

research report Fire Resistance Ratings of Load Bearing Steel Stud Walls With Gypsum Wallboard Protection RESEARCH REPORT RP REVISION 2007

Gold Bond BRAND Gypsum Sheathing

One and Two Family Additions

ANALYSIS AND DESIGN OF MOMENT RESISTING MIDWALL BY THE STEEL NETWORK, INC.

Project Findings: Appendix 2

Project Findings: Appendix 2

Eric Alwine Structural Option George Read Hall The University of Delaware Dr. Boothby Technical Assignment #2 October 31, 2005 EXECUTIVE SUMMARY:

Retain "Preinstallation Conference" Paragraph below if Work of this Section is extensive or complex enough to justify a conference.

Plan Check No. Checked by: An Appointment Is Required for Verification

Introducing TJ Insulated Structural Framing Components

Building Guide. Colorado Chapter of the International Code Council

STRUCTURAL ABBREVIATIONS S-001 GENERAL NOTES CONCRETE MASONRY NOTES DESIGN NOTES SOF NSWG-10 UAS SUPPORT FACILITY FY 2016 MILCON P-225

DETAIL DRAWINGS. RASTRA is a stay-in-place insulated concrete. form that is structurally strong, energy-efficient,

Renovation of Buildings using Steel Technologies (ROBUST)

FDA CDRH Laboratory Silver Spring, Maryland. Executive Summary: Timothy Mueller Structural Option Walter Schneider

Product Designation As specified in the AISI standard for cold formed steel framing General provisions A5.2.

Residential Inspector s Guide: Building and Energy based on the 2009 International Residential Code Chapters 1-11

Residential Inspector s Guide: Building and Energy based on the 2009 International Residential Code Chapters 1-11

TYPICAL BEARING WALL FRAMING

Supplemental Plan Check List for Unreinforced Masonry (URM) Retrofit

SECTION (05400) - COLD-FORMED METAL FRAMING

Thermal Bridging and Whole Building Energy Performance

Chapter 2 EARTHQUAKE-RESISTANCE REQUIREMENTS

PRICELESS HEADER & KWIK-JAMB SYSTEM IAPMO UNIFORM ER 0342

HOTEL NORTHEAST U.S. JORDAN RUTHERFORD STRUCTURAL OPTION FACULTY ADVISOR DR. THOMAS BOOTHBY AE SENIOR THESIS APRIL 8, 2013

NCMA TEK TEK 19-5A FLASHING DETAILS FOR CONCRETE MASONRY WALLS

INFORMATIONAL PACKAGE ACCESSORY RESIDENTIAL BUILDINGS (INCLUDING DETACHED GARAGES, STORAGE BUILDINGS & WORKSHOPS)

RESEARCH HIGHLIGHT. Design and Construction of the Northern Sustainable House Arviat, Nunavut

AcroWall-ES System. Class PB Exterior Insulation and Finish System providing a primary moisture barrier. Typical Details

Pella 250 Series. Wood Frame Construction with Vinyl Siding... V250-ID-888 Wood Frame Construction with Brick Veneer...

Senershield -R / Senershield -VB

City of Richmond Zoning Ordinance Page 12-1

Detailing For Wood Shrinkage

SLIDING Product Information

2003 International Residential Building Code

STATE OF NEW HAMPSHIRE DEPARTMENT OF NATURAL AND CULTURAL RESOURCES DIVISION OF PARKS AND RECREATION SKI PATROL HUT PROJECT #: CAP 1804

UL Design System HW-D-1012 continued

DIVISION: CONCRETE SECTION: INSULATING CONCRETE FORMING REPORT HOLDER: AMVIC INCORPORATED

Lightweight Steel Framing. Composite DeltaStud Load Tables

Table of Contents.2. Introduction...3 Gravity Loading and Deflections..4. Existing Structural System..8

FIRESTOP JOINT SPRAY CFS-SP WB. 2mm (0.079") WET FILM ± 7.5 ± 5

Halfen systems for the support and restraint of brickwork

SECTION COLD-FORMED METAL FRAMING

ENERGY EFFICIENT BUILDING STRUCTURE. ...more than brick.

CITY OF CEDAR FALLS DEPARTMENT OF DEVELOPMENTAL SERVICES INSPECTION SERVICES DIVISION PHONE Residential Accessory Structures

Hilton Baltimore Convention Center Hotel Western Podium

POST AND FRAME STRUCTURES (Pole Barns)

HAMBRO COMPOSITE FLOOR SYSTEM

Structural Technical Report #2 By Robert Whitaker

CHAPTER 5 FLOORS SECTION R501

Hansen Pole Buildings Planning Guide. Toll Free / Toll Free FAX

WARRANTY PROVIDER ACCEPTED A REFERENCE GUIDE OF TYPICAL RAINSCREEN WALL AND WINDOW DETAILS

PLYWOOD FLOATING FLOOR

Brent Ellmann Structural Option 200 Minuteman Park, Andover, MA Structural Consultant: Dr. Hanagan

Shaftwall and Area Separation Wall Systems.

Open-Web Trusses. Including Red-L, Red-W, Red-S, Red-M and Red-H Trusses. Design Flexibility. Outstanding Strength-to-Weight Performance

Structural System. Design Criteria Fire Resistance Concrete designed for 2 HR rating (worst case) Geotechnical Report Allowable Bearing Capacity

ILLUSTRATED GUIDE. For Seismic Design of Houses. Lateral Bracing Requirements Part 9 BC Building Code 2012

Open-Web Trusses. Including Red-L, Red-W, Red-S, Red-M and Red-H Trusses. Design Flexibility. Outstanding Strength-to-Weight Performance

Durham, NC : Phone (919) Toll Free Nationwide Phone : (888)

HIGHLANDVIEW CEMETERY CHAPEL

STRUCTURAL ISSUES IN RESIDENTIAL CONSTRUCTION. Presented by: Susan L. Lasecki P.E., S.E.

Insulation Retrofit Options

BROCHURE # 108 CONSTRUCTION PLAN COMPONENTS

KNIGHT WALL SYSTEMS GUIDE DETAILS:

SECTION D Masonry Wall Systems. Contents. Introduction. Design Considerations. Installation. Components. System Specifications.

THE DISASTERS OF SEPTEMBER 11, 2001 DAVID T. BIGGS, P.E. Principal Ryan-Biggs Associates, P.C. Troy, New York USA

90% Design Submittal Structural Calculations Parking Garage CDRL

Transcription:

LIGHTWEIGHT STEEL FRAMING DETAILS GENERAL & WIND BEARING THE STRENGTH WITHIN MONTREAL TORONTO CALGARY EDMONTON VANCOUVER

WALL ELEVAT IO N S Bailey Wind Bearing Walls (BWB) Lightweight Steel Framing Bailey Axial Loadbearing (LSF) provides economical structural support for finishes under Walls (BAB) Lightweight lateral wind loads on buildings where other structural components Steel Framing (LSF) supports carry axial loads. BWB walls can be designed for a variety of the combined axial and wind deflection limits for finishes such as EIFS, Stucco, Metal Panel loads on interior and exterior and Brick Veneer. Wind-Bearing LSF may be used in buildings walls. Buildings up to six stories of any height. in height can be framed using LSF. LSF works with a variety of floors including LSF Joists, ComSlab composite flooring systems, OWSJ s and hollow precast concrete. EXTERIOR INFILL WALLS / CONTINUOUS EXTERIOR CURTAIN WALLS AXIAL LOAD BEARING WALLS 2 L I G H T W E I G H T S T E E L F R A M I N G D E TA I L S G E N E R A L & W I N D B E A R I N G

Bailey Joists for Floors & Roofs Lightweight Steel Framing (LSF) Joists offer a wide range of span and load capabilities for commercial and residential floor systems and mezzanines. LSF ceiling Joist members can also be utilized for pitched, mansard and flat roofs. The use of Bailey LSF Joist members will provide support for interior drywall ceilings where long clear spans are required. Bailey Non-Loadbearing Walls (BNLB) Lightweight Steel Framing (LSF) provides an effective solution for interior non-load bearing walls and partitions. When combined with top track deflection members, bulkheads will resist buckling caused by deflection Bailey Spandrel Walls Lightweight Steel Framing (LSF) accommodates a variety of spans for continuous strip window applications. LSF provides a stable, square platform in which glazing units and frames can be effectively installed. of floor and roof assemblies. Non-load bearing LSF provides a stable framework for drywall or other finished wall surface applications. SPANDREL WALLS FOR CONTINUOUS STRIP WINDOWS JOISTS FOR FLOORS & ROOFS TALL INTERIOR PARTITIONS The material presented in this document has been prepared for the general information of the reader. While the material is believed to be technically correct and in accordance with recognized good practice, it should not be used without first securing competent advice with respect to its suitability for any specific application. Bailey Metal Products Limited does not warrant or assume liability for the suitability of the material for any general or particular use. WWW.BMP-GROUP.COM 3

WALL ELEVATIONS WIND LOADBEARING INFILL WALL WIND LOADBEARING CONTINUOUS CURTAIN WALLS WIND LOADBEARING SPANDREL WALL FOR STRIP WINDOWS 4 LIGHTWEIGHT STEEL FRAMING DETAILS GENERAL & WIND BEARING

GENERAL DETAILS BAILEY STUD TO BAILEY TRACK BAILEY STUD TO BAILEY PATENTED PUNCHED TRACK 1 2 3 BAILEY STUD REINFORCED WITH BAILEY TRACK BAILEY STUD WITH WEB STIFFENER REINFORCING JAMB STUD AT DOOR OPENING 4 5 6 BAILEY STUD TO BAILEY TRACK AT CORNERS THROUGH-THE-STUD 7 FLAT STRAP BRIDGING BRIDGING 8 9 NOTCHED CHANNEL BRIDGING EXTERIOR RIGID 10 EXTERIOR SHEATHING 11 INSULATION 12 EXTERIOR SHEATHING AND RIGID INSULATION WWW.BMP-GROUP.COM 5

WIND BEARING WALLS CONTINUOUS WIND BEARING STUD AT PARAPET WIND BEARING INFILL WALL 13 14 15 SPANDREL WALL FOR STRIP WINDOWS 6 LIGHTWEIGHT STEEL FRAMING DETAILS GENERAL & WIND BEARING

WIND BEARING WALLS DETAILS AT OPENINGS 21 HEAD TRACK TO JAMB STUDS WIND BEARING WALLS DEFLECTION DETAILS 16 SINGLE DEFLECTION TRACK 17 HORIZONTAL FLANGE ATTACHMENT (HFA) CLIP 22 SILL TRACK TO JAMB STUDS 18 DEFLECTION TRACK 23 REINFORCED HEAD TRACK TO JAMB STUD 19 SLOTTED DEFLECTION CLIP (Radius Wall Applications) 20 BAILEY MULTI-SLOT TRACK 24 REINFORCED SILL TRACK TO JAMB STUD WWW.BMP-GROUP.COM 7

LIGHTWEIGHT STEEL FRAMING DETAILS GENERAL & WIND BEARING sales@bmp-group.com www.bmp-group.com GWB07IN16-500 MONTREAL TORONTO CALGARY EDMONTON VANCOUVER 525 Avenue Edward VII Dorval, QC H9P 1E7 Tel. (514) 735-3455 800-263-3455 Fax. (514) 735-5052 1 Caldari Road Concord, ON L4K 3Z9 Tel. (905) 738-9267 800-668-2154 Fax. (905) 738-5712 3924 27th Street NE Calgary, AB T1Y 5K7 Tel. (403) 248-3536 800-665-2013 Fax. (403) 248-0288 5710 Roper Road NW Edmonton, AB T6B 3G7 Tel. (780) 462-5757 800-563-1751 Fax. (780) 450-3378 7715 Anvil Way Surrey, BC V3W 6A2 Tel. (604) 590-5100 800-818-2666 Fax. (604) 590-5105